{"lab":{"_id":"69ad52a3de79e566650fb6e0","accr_number":"AB 1343","country":"PL","accr_body":"PCA","address":"ul. Muchoborska 18, 54-424 Wrocław","categories":["water","environment","microbiology"],"city":"Wrocław","imported_at":"2026-03-08T10:42:43.265Z","methods_count":19,"name":"ECOCENTRUM ELŻBIETA WOLNY","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1343.pdf"],"scope_summary":"","search_text":"ecocentrum elżbieta wolny ul. muchoborska 18, 54-424 wrocław water microbiology other pharma electronics environment","status":"active","updated_at":"2026-03-08T14:50:31.158Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:31.158Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201343,podmiot.html","parse_date":"2026-07-17T16:19:04.431Z","parse_source":"m5-mistral-qa","fields_of_testing":[{"codes":"C/28/P; C/29/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi","en":"Chemical tests and sampling of water, drinking water"},{"codes":"N/28/P; N/29/P; N/30/P; N/31/P; N/32/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków, gleby, osadów","en":"Tests of physical properties and sampling of water, drinking water, sewage, soil, sediments"},{"codes":"P/28; P/29; P/30; P/31; P/32","pl":"Pobieranie próbek wody, wody do spożycia przez ludzi, ścieków, gleby, osadów, odpadów","en":"Sampling of water, drinking water, sewage, soil, sediments, waste"}],"issue":{"no":"14","date":"29.04.2025"},"map_coord":[51.107829,16.970422],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":11,"environment":8,"microbiology":6},"category_scores":{"water":4.84,"environment":2.56,"microbiology":1.44},"has_zh":true},"methods":[{"_id":"6a5a55f89af9f73f38252416","lab_id":"69ad52a3de79e566650fb6e0","country":"PL","accr_number":"AB 1343","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody Zakres: (0,0 – 65,0) C","methodology_en":"Sampling for chemical and physical testing Temperature of the collected water sample Range: (0,0 – 65,0) C","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody Zakres: (0,0 – 65,0) C","reference":"PN-ISO 5667-5:2017-10 PB-01-05 z dnia 31.03.2025 r.","norm_bases":["PN-ISO 5667-5:2017-10 PB-01-05 z dnia 31.03.2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody Zakres: (0,0 – 65,0) C PN-ISO 5667-5:2017-10 PB-01-05 z dnia 31.03.2025 r. Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych Temperatura pobranej probki wody Zakres: (0,0 – 65,0) C PN-ISO 5667-5:2017-10 PB-01-05 z dnia 31.03.2025 r.","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Sampling for chemical and physical testing Temperature of the collected water sample Range: (0,0 – 65,0) C PN-ISO 5667-5:2017-10 PB-01-05 z dnia 31.03.2025 r.","search_zh":"生活饮用水 PN-ISO 5667-5:2017-10 PB-01-05 z dnia 31.03.2025 r.","test_object_zh":"生活饮用水"},{"_id":"6a5a55f89af9f73f38252417","lab_id":"69ad52a3de79e566650fb6e0","country":"PL","accr_number":"AB 1343","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody Zakres: (0,0 – 65,0) C","methodology_en":"Sampling for chemical and physical testing Temperature of the collected water sample Range: (0,0 – 65,0) C","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody Zakres: (0,0 – 65,0) C","reference":"PN-EN ISO 5667-6:2016-12 z wyłączeniem punktu 7.2 | PB-01-05","norm_bases":["PN-EN ISO 5667-6:2016-12 z wyłączeniem punktu 7.2","PB-01-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody Zakres: (0,0 – 65,0) C PN-EN ISO 5667-6:2016-12 z wyłączeniem punktu 7.2 | PB-01-05 Woda Pobieranie probek do badan chemicznych i fizycznych Temperatura pobranej probki wody Zakres: (0,0 – 65,0) C PN-EN ISO 5667-6:2016-12 z wylaczeniem punktu 7.2 | PB-01-05","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Sampling for chemical and physical testing Temperature of the collected water sample Range: (0,0 – 65,0) C PN-EN ISO 5667-6:2016-12 z wyłączeniem punktu 7.2 | PB-01-05","search_zh":"水 PN-EN ISO 5667-6:2016-12 z wyłączeniem punktu 7.2 | PB-01-05","test_object_zh":"水"},{"_id":"6a5a55f89af9f73f38252418","lab_id":"69ad52a3de79e566650fb6e0","country":"PL","accr_number":"AB 1343","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi Woda","test_object_en":"Water intended for human consumption Water","methodology":"Pobieranie próbek do badań mikrobiologicznych","methodology_en":"Sampling for microbiological testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007 z wyłączeniem punktu 4.4.4.1","norm_bases":["PN-EN ISO 19458:2007 z wyłączeniem punktu 4.4.4.1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Woda Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 z wyłączeniem punktu 4.4.4.1 Woda do spozycia przez ludzi Woda Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007 z wylaczeniem punktu 4.4.4.1","categories":["water","microbiology"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Water Sampling for microbiological testing PN-EN ISO 19458:2007 z wyłączeniem punktu 4.4.4.1","methodology_zh":"微生物检测用样品采集","search_zh":"生活饮用水 水 微生物检测用样品采集 PN-EN ISO 19458:2007 z wyłączeniem punktu 4.4.4.1","test_object_zh":"生活饮用水 水"},{"_id":"6a5a55f89af9f73f38252419","lab_id":"69ad52a3de79e566650fb6e0","country":"PL","accr_number":"AB 1343","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi Woda","test_object_en":"Water intended for human consumption Water","methodology":"Stężenie chloru ogólnego Zakres: (0,02 – 8,0) mg/l Stężenie chloru wolnego Zakres: (0,02 – 8,0) mg/l Metoda kolorymetryczna Chlor związany (z obliczeń)","methodology_en":"Total chlorine concentration Range: (0,02 – 8,0) mg/l Free chlorine concentration Range: (0,02 – 8,0) mg/l Colorimetric method Combined chlorine (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chloru ogólnego Zakres: (0,02 – 8,0) mg/l Stężenie chloru wolnego Zakres: (0,02 – 8,0) mg/l Metoda kolorymetryczna Chlor związany (z obliczeń)","reference":"PB-06-03 z dnia 02.01.2020 r. na podstawie metod HACH nr 8021, 8167, 10069, 10070","norm_bases":["PB-06-03 z dnia 02.01.2020 r. na podstawie metod HACH nr 8021, 8167, 10069, 10070"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Woda Stężenie chloru ogólnego Zakres: (0,02 – 8,0) mg/l Stężenie chloru wolnego Zakres: (0,02 – 8,0) mg/l Metoda kolorymetryczna Chlor związany (z obliczeń) PB-06-03 z dnia 02.01.2020 r. na podstawie metod HACH nr 8021, 8167, 10069, 10070 Woda do spozycia przez ludzi Woda Stezenie chloru ogolnego Zakres: (0,02 – 8,0) mg/l Stezenie chloru wolnego Zakres: (0,02 – 8,0) mg/l Metoda kolorymetryczna Chlor zwiazany (z obliczen) PB-06-03 z dnia 02.01.2020 r. na podstawie metod HACH nr 8021, 8167, 10069, 10070","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Water Total chlorine concentration Range: (0,02 – 8,0) mg/l Free chlorine concentration Range: (0,02 – 8,0) mg/l Colorimetric method Combined chlorine (calculated) PB-06-03 z dnia 02.01.2020 r. na podstawie metod HACH nr 8021, 8167, 10069, 10070","search_zh":"生活饮用水 水 PB-06-03 z dnia 02.01.2020 r. na podstawie metod HACH nr 8021, 8167, 10069, 10070","test_object_zh":"生活饮用水 水"},{"_id":"6a5a55f89af9f73f3825241a","lab_id":"69ad52a3de79e566650fb6e0","country":"PL","accr_number":"AB 1343","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna i metoda automatyczna Temperatura ścieku / pobranej próbki ścieku Zakres: (0,0 – 65,0) C","methodology_en":"Sampling for chemical and physical testing Manual method and automatic method Temperature of wastewater / of the wastewater sample taken Range: (0,0 – 65,0) C","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna i metoda automatyczna Temperatura ścieku / pobranej próbki ścieku Zakres: (0,0 – 65,0) C","reference":"PN-ISO 5667-10:2021-11 PB-01-05 z dnia 31.03.2025 r.","norm_bases":["PN-ISO 5667-10:2021-11 PB-01-05 z dnia 31.03.2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna i metoda automatyczna Temperatura ścieku / pobranej próbki ścieku Zakres: (0,0 – 65,0) C PN-ISO 5667-10:2021-11 PB-01-05 z dnia 31.03.2025 r. Scieki Pobieranie probek do badan chemicznych i fizycznych Metoda manualna i metoda automatyczna Temperatura scieku / pobranej probki scieku Zakres: (0,0 – 65,0) C PN-ISO 5667-10:2021-11 PB-01-05 z dnia 31.03.2025 r.","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Sampling for chemical and physical testing Manual method and automatic method Temperature of wastewater / of the wastewater sample taken Range: (0,0 – 65,0) C PN-ISO 5667-10:2021-11 PB-01-05 z dnia 31.03.2025 r.","search_zh":"污水 PN-ISO 5667-10:2021-11 PB-01-05 z dnia 31.03.2025 r.","test_object_zh":"污水"},{"_id":"6a5a55f89af9f73f3825241b","lab_id":"69ad52a3de79e566650fb6e0","country":"PL","accr_number":"AB 1343","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań mikrobiologicznych","methodology_en":"Sampling for microbiological testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007","norm_bases":["PN-EN ISO 19458:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 Scieki Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007","categories":["water","microbiology"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Sampling for microbiological testing PN-EN ISO 19458:2007","methodology_zh":"微生物检测用样品采集","search_zh":"污水 微生物检测用样品采集 PN-EN ISO 19458:2007","test_object_zh":"污水"},{"_id":"6a5a55f89af9f73f3825241c","lab_id":"69ad52a3de79e566650fb6e0","country":"PL","accr_number":"AB 1343","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi Woda Ścieki","test_object_en":"Water intended for human consumption Water Wastewater","methodology":"pH Zakres: 4,0 – 10,0 Metoda potencjometryczna","methodology_en":"pH Range: 4,0 – 10,0 Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH Zakres: 4,0 – 10,0 Metoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Woda Ścieki pH Zakres: 4,0 – 10,0 Metoda potencjometryczna PN-EN ISO 10523:2012 Woda do spozycia przez ludzi Woda Scieki pH Zakres: 4,0 – 10,0 Metoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Water Wastewater pH Range: 4,0 – 10,0 Potentiometric method PN-EN ISO 10523:2012","methodology_zh":"pH 范围：4,0 – 10,0 电位法","search_zh":"生活饮用水 水 废水 pH 范围：4,0 – 10,0 电位法 PN-EN ISO 10523:2012","test_object_zh":"生活饮用水 水 废水"},{"_id":"6a5a55f89af9f73f3825241d","lab_id":"69ad52a3de79e566650fb6e0","country":"PL","accr_number":"AB 1343","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi Woda Ścieki","test_object_en":"Water intended for human consumption Water Wastewater","methodology":"Przewodność elektryczna właściwa Zakres: (100 – 13000) µS/cm Metoda konduktometryczna","methodology_en":"Electrical conductivity Range: (100 – 13000) µS/cm Conductometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa Zakres: (100 – 13000) µS/cm Metoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Woda Ścieki Przewodność elektryczna właściwa Zakres: (100 – 13000) µS/cm Metoda konduktometryczna PN-EN 27888:1999 Woda do spozycia przez ludzi Woda Scieki Przewodnosc elektryczna wlasciwa Zakres: (100 – 13000) µS/cm Metoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Water Wastewater Electrical conductivity Range: (100 – 13000) µS/cm Conductometric method PN-EN 27888:1999","search_zh":"生活饮用水 水 废水 PN-EN 27888:1999","test_object_zh":"生活饮用水 水 废水"},{"_id":"6a5a55f89af9f73f3825241e","lab_id":"69ad52a3de79e566650fb6e0","country":"PL","accr_number":"AB 1343","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 10381-4:2007","norm_bases":["PN-ISO 10381-4:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 10381-4:2007 Gleba Pobieranie probek do badan chemicznych i fizycznych PN-ISO 10381-4:2007","categories":["environment"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil Sampling for chemical and physical testing PN-ISO 10381-4:2007","methodology_zh":"化学与物理检测用样品采集","search_zh":"土壤 化学与物理检测用样品采集 PN-ISO 10381-4:2007","test_object_zh":"土壤"},{"_id":"6a5a55f89af9f73f3825241f","lab_id":"69ad52a3de79e566650fb6e0","country":"PL","accr_number":"AB 1343","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Pobieranie próbek do badań mikrobiologicznych","methodology_en":"Sampling for microbiological testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PB-04-03 z dnia 02.01.2020 r.","norm_bases":["PB-04-03 z dnia 02.01.2020 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Pobieranie próbek do badań mikrobiologicznych PB-04-03 z dnia 02.01.2020 r. Gleba Pobieranie probek do badan mikrobiologicznych PB-04-03 z dnia 02.01.2020 r.","categories":["environment","microbiology"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil Sampling for microbiological testing PB-04-03 z dnia 02.01.2020 r.","methodology_zh":"微生物检测用样品采集","search_zh":"土壤 微生物检测用样品采集 PB-04-03 z dnia 02.01.2020 r.","test_object_zh":"土壤"},{"_id":"6a5a55f89af9f73f38252420","lab_id":"69ad52a3de79e566650fb6e0","country":"PL","accr_number":"AB 1343","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"pH – w H O 2 Zakres: 4,0 – 10,0 Metoda potencjometryczna","methodology_en":"pH – in H O 2 Range: 4,0 – 10,0 Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH – w H O 2 Zakres: 4,0 – 10,0 Metoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba pH – w H O 2 Zakres: 4,0 – 10,0 Metoda potencjometryczna PN-EN ISO 10390:2022-09 Gleba pH – w H O 2 Zakres: 4,0 – 10,0 Metoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["environment"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil pH – in H O 2 Range: 4,0 – 10,0 Potentiometric method PN-EN ISO 10390:2022-09","search_zh":"土壤 pH － 于 H2O 中 范围：4,0 – 10,0 电位法 PN-EN ISO 10390:2022-09","test_object_zh":"土壤","methodology_zh":"pH － 于 H2O 中 范围：4,0 – 10,0 电位法"},{"_id":"6a5a55f89af9f73f38252421","lab_id":"69ad52a3de79e566650fb6e0","country":"PL","accr_number":"AB 1343","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-EN ISO 5667-13:2011 z wyłączeniem punktu 6.3.4","norm_bases":["PN-EN ISO 5667-13:2011 z wyłączeniem punktu 6.3.4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Pobieranie próbek do badań chemicznych i fizycznych PN-EN ISO 5667-13:2011 z wyłączeniem punktu 6.3.4 Osady sciekowe Pobieranie probek do badan chemicznych i fizycznych PN-EN ISO 5667-13:2011 z wylaczeniem punktu 6.3.4","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sewage sludge Sampling for chemical and physical testing PN-EN ISO 5667-13:2011 z wyłączeniem punktu 6.3.4","methodology_zh":"化学与物理检测用样品采集","search_zh":"污泥 化学与物理检测用样品采集 PN-EN ISO 5667-13:2011 z wyłączeniem punktu 6.3.4","test_object_zh":"污泥"},{"_id":"6a5a55f89af9f73f38252422","lab_id":"69ad52a3de79e566650fb6e0","country":"PL","accr_number":"AB 1343","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Pobieranie próbek do badań mikrobiologicznych","methodology_en":"Sampling for microbiological testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PB-04-03 z dnia 02.01.2020 r.","norm_bases":["PB-04-03 z dnia 02.01.2020 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Pobieranie próbek do badań mikrobiologicznych PB-04-03 z dnia 02.01.2020 r. Osady sciekowe Pobieranie probek do badan mikrobiologicznych PB-04-03 z dnia 02.01.2020 r.","categories":["water","microbiology"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sewage sludge Sampling for microbiological testing PB-04-03 z dnia 02.01.2020 r.","methodology_zh":"微生物检测用样品采集","search_zh":"污泥 微生物检测用样品采集 PB-04-03 z dnia 02.01.2020 r.","test_object_zh":"污泥"},{"_id":"6a5a55f89af9f73f38252423","lab_id":"69ad52a3de79e566650fb6e0","country":"PL","accr_number":"AB 1343","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"pH – w H O 2 Zakres: 4,0 – 10,0 Metoda potencjometryczna","methodology_en":"pH – in H O 2 Range: 4,0 – 10,0 Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH – w H O 2 Zakres: 4,0 – 10,0 Metoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe pH – w H O 2 Zakres: 4,0 – 10,0 Metoda potencjometryczna PN-EN ISO 10390:2022-09 Osady sciekowe pH – w H O 2 Zakres: 4,0 – 10,0 Metoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sewage sludge pH – in H O 2 Range: 4,0 – 10,0 Potentiometric method PN-EN ISO 10390:2022-09","search_zh":"污泥 pH － 于 H2O 中 范围：4,0 – 10,0 电位法 PN-EN ISO 10390:2022-09","test_object_zh":"污泥","methodology_zh":"pH － 于 H2O 中 范围：4,0 – 10,0 电位法"},{"_id":"6a5a55f89af9f73f38252424","lab_id":"69ad52a3de79e566650fb6e0","country":"PL","accr_number":"AB 1343","accr_body":"PCA","test_object":"Odpady O) kod: 02 03 80","test_object_en":"Waste O) code: 02 03 80","methodology":"Pobieranie próbek do badań mikrobiologicznych","methodology_en":"Sampling for microbiological testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PB-04-03 z dnia 02.01.2020 r.","norm_bases":["PB-04-03 z dnia 02.01.2020 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O) kod: 02 03 80 Pobieranie próbek do badań mikrobiologicznych PB-04-03 z dnia 02.01.2020 r. Odpady O) kod: 02 03 80 Pobieranie probek do badan mikrobiologicznych PB-04-03 z dnia 02.01.2020 r.","categories":["environment","microbiology"],"row_index":14,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste O) code: 02 03 80 Sampling for microbiological testing PB-04-03 z dnia 02.01.2020 r.","methodology_zh":"微生物检测用样品采集","search_zh":"微生物检测用样品采集 PB-04-03 z dnia 02.01.2020 r."},{"_id":"6a5a55f89af9f73f38252425","lab_id":"69ad52a3de79e566650fb6e0","country":"PL","accr_number":"AB 1343","accr_body":"PCA","test_object":"Odpady O) kod: 02 03 01, 02 03 80","test_object_en":"Waste O) code: 02 03 01, 02 03 80","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-EN ISO 5667-13:2011 z wyłączeniem punktu 6.3.4 | IB-05-04","norm_bases":["PN-EN ISO 5667-13:2011 z wyłączeniem punktu 6.3.4","IB-05-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O) kod: 02 03 01, 02 03 80 Pobieranie próbek do badań chemicznych i fizycznych PN-EN ISO 5667-13:2011 z wyłączeniem punktu 6.3.4 | IB-05-04 Odpady O) kod: 02 03 01, 02 03 80 Pobieranie probek do badan chemicznych i fizycznych PN-EN ISO 5667-13:2011 z wylaczeniem punktu 6.3.4 | IB-05-04","categories":["environment"],"row_index":15,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste O) code: 02 03 01, 02 03 80 Sampling for chemical and physical testing PN-EN ISO 5667-13:2011 z wyłączeniem punktu 6.3.4 | IB-05-04","methodology_zh":"化学与物理检测用样品采集","search_zh":"化学与物理检测用样品采集 PN-EN ISO 5667-13:2011 z wyłączeniem punktu 6.3.4 | IB-05-04"},{"_id":"6a5a55f89af9f73f38252426","lab_id":"69ad52a3de79e566650fb6e0","country":"PL","accr_number":"AB 1343","accr_body":"PCA","test_object":"Odpady O) kod: 02 03 99, 02 03 81, 19 08 05, 19 08 01, 19 08 02, 19 06 06, 19 06 05, 02 03 05","test_object_en":"Waste O) code: 02 03 99, 02 03 81, 19 08 05, 19 08 01, 19 08 02, 19 06 06, 19 06 05, 02 03 05","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-EN ISO 5667-13:2011 z wyłączeniem punktu 6.3.4 | IB-05-04","norm_bases":["PN-EN ISO 5667-13:2011 z wyłączeniem punktu 6.3.4","IB-05-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O) kod: 02 03 99, 02 03 81, 19 08 05, 19 08 01, 19 08 02, 19 06 06, 19 06 05, 02 03 05 Pobieranie próbek do badań chemicznych i fizycznych PN-EN ISO 5667-13:2011 z wyłączeniem punktu 6.3.4 | IB-05-04 Odpady O) kod: 02 03 99, 02 03 81, 19 08 05, 19 08 01, 19 08 02, 19 06 06, 19 06 05, 02 03 05 Pobieranie probek do badan chemicznych i fizycznych PN-EN ISO 5667-13:2011 z wylaczeniem punktu 6.3.4 | IB-05-04","categories":["environment"],"row_index":16,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste O) code: 02 03 99, 02 03 81, 19 08 05, 19 08 01, 19 08 02, 19 06 06, 19 06 05, 02 03 05 Sampling for chemical and physical testing PN-EN ISO 5667-13:2011 z wyłączeniem punktu 6.3.4 | IB-05-04","methodology_zh":"化学与物理检测用样品采集","search_zh":"化学与物理检测用样品采集 PN-EN ISO 5667-13:2011 z wyłączeniem punktu 6.3.4 | IB-05-04"},{"_id":"6a5a55f89af9f73f38252427","lab_id":"69ad52a3de79e566650fb6e0","country":"PL","accr_number":"AB 1343","accr_body":"PCA","test_object":"Odpady O) kod: 19 08 05, 19 08 01, 19 08 02, 19 06 06, 19 06 05, 02 03 05","test_object_en":"Waste O) code: 19 08 05, 19 08 01, 19 08 02, 19 06 06, 19 06 05, 02 03 05","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-EN ISO 5667-13:2011 z wyłączeniem punktu 6.3.4","norm_bases":["PN-EN ISO 5667-13:2011 z wyłączeniem punktu 6.3.4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O) kod: 19 08 05, 19 08 01, 19 08 02, 19 06 06, 19 06 05, 02 03 05 Pobieranie próbek do badań chemicznych i fizycznych PN-EN ISO 5667-13:2011 z wyłączeniem punktu 6.3.4 Odpady O) kod: 19 08 05, 19 08 01, 19 08 02, 19 06 06, 19 06 05, 02 03 05 Pobieranie probek do badan chemicznych i fizycznych PN-EN ISO 5667-13:2011 z wylaczeniem punktu 6.3.4","categories":["environment"],"row_index":17,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste O) code: 19 08 05, 19 08 01, 19 08 02, 19 06 06, 19 06 05, 02 03 05 Sampling for chemical and physical testing PN-EN ISO 5667-13:2011 z wyłączeniem punktu 6.3.4","methodology_zh":"化学与物理检测用样品采集","search_zh":"化学与物理检测用样品采集 PN-EN ISO 5667-13:2011 z wyłączeniem punktu 6.3.4"},{"_id":"6a5a55f89af9f73f38252428","lab_id":"69ad52a3de79e566650fb6e0","country":"PL","accr_number":"AB 1343","accr_body":"PCA","test_object":"Odpady O) kod: 19 08 05, 19 06 06, 19 06 05, 02 03 05","test_object_en":"Waste O) code: 19 08 05, 19 06 06, 19 06 05, 02 03 05","methodology":"Pobieranie próbek do badań mikrobiologicznych","methodology_en":"Sampling for microbiological testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PB-04-03 z dnia 02.01.2020 r.","norm_bases":["PB-04-03 z dnia 02.01.2020 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O) kod: 19 08 05, 19 06 06, 19 06 05, 02 03 05 Pobieranie próbek do badań mikrobiologicznych PB-04-03 z dnia 02.01.2020 r. Odpady O) kod: 19 08 05, 19 06 06, 19 06 05, 02 03 05 Pobieranie probek do badan mikrobiologicznych PB-04-03 z dnia 02.01.2020 r.","categories":["environment","microbiology"],"row_index":18,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste O) code: 19 08 05, 19 06 06, 19 06 05, 02 03 05 Sampling for microbiological testing PB-04-03 z dnia 02.01.2020 r.","methodology_zh":"微生物检测用样品采集","search_zh":"微生物检测用样品采集 PB-04-03 z dnia 02.01.2020 r."}],"has_pdf":true}