🇵🇱 QEMETICA Soda Polska S.A. PL
Water & wastewater
QEMETICA Soda Polska S.A. is a laboratory accredited by PCA under number AB 1338 (Inowrocław, Poland). Its accreditation scope covers 16 test methods in the following areas: Water & wastewater. Test objects include: Water, wastewater, Wastewater, Water.
At a glance
- Accreditation number: PCA AB 1338
- Methods in scope: 16
- Types of test objects: 3
- City: Inowrocław, Poland
- Accreditation number
- AB 1338
- Accreditation body
- PCA
- Address
- DZIAŁ JAKOŚCI, LABORATORIUM OCHRONY ŚRODOWISKA, ul. Fabryczna 4, 88-101 Inowrocław
- City
- Inowrocław, Poland
What this laboratory tests (3)
- Water, wastewater — 12 methods
- Wastewater — 2 methods
- Water — 2 methods
Accreditation scope — test methods (16)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Water | Sampling for chemical and physical testing Manual method Temperature of the water sample taken Range: (1,0 - 50)°C | PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2 | PN-ISO 5667-4:2017-10 z wyłączeniem pkt. 13 | PN-77/C-04584 | ||
| 2 | Water | Nitrite nitrogen concentration Range: (0,01 - 0,25) mg/l Spectrophotometric method | PN-EN 26777:1999 | ||
| 3 | Wastewater | Sampling for chemical and physical testing Manual method Automatic method Temperature of wastewater / of the wastewater sample taken Range: (1,0 - 50)°C | PN-ISO 5667-10:2021-11 PN-77/C-04584 | ||
| 4 | Wastewater | Nitrite nitrogen concentration Range: (0,01 - 10,0) mg/l Spectrophotometric method | PN-EN 26777:1999 | ||
| 5 | Water, wastewater | pH Range: 2,0 – 12,0 Potentiometric method | PN-EN ISO 10523:2012 | ||
| 6 | Water, wastewater | Sulfate concentration Range: (10 - 1000) mg/l Gravimetric method | PN-ISO 9280:2002 | ||
| 7 | Water, wastewater | Ammonium nitrogen concentration Range: (0,2 - 1000) mg/l Titrimetric method | PN-ISO 5664:2002 | ||
| 8 | Water, wastewater | Kjeldahl nitrogen concentration Range: (1 - 100) mg/l Titrimetric method | PN-EN 25663:2001 | ||
| 9 | Water, wastewater | Nitrate nitrogen concentrations Range: (0,1 - 50) mg/l Spectrophotometric method | PN-82/C-04576.08 | ||
| 10 | Water, wastewater | Chloride concentration Range: (5 - 75000) mg/l Titrimetric method | PN-ISO 9297:1994 | ||
| 11 | Water, wastewater | Total nitrogen concentration (calculated) | Procedura badawcza PB-ZLŚ-28, wydanie 4 z dnia 13.03.2025 | ||
| 12 | Water, wastewater | Total suspended solids Range: (2,0 - 1000) mg/l Gravimetric method | PN-EN 872:2007+Ap1:2007 | ||
| 13 | Water, wastewater | Chemical oxygen demand COD-Cr Range: (6,0 - 150) mg/l O2 Spectrophotometric method | PN-ISO 15705:2005 | ||
| 14 | Water, wastewater | Biochemical oxygen demand - BOD 5 Range: (2,0 - 6,0) mg/l O 2 Titrimetric method | PN-EN 1899-2:2002 | ||
| 15 | Water, wastewater | Biochemical oxygen demand - BOD 5 Range: (3 - 100) mg/l O 2 Titrimetric method | PN-EN ISO 5815-1:2019-12 | ||
| 16 | Water, wastewater | Electrical conductivity Range: (200 – 200000) µS/cm Conductometric method | PN-EN 27888:1999 | ||
Reference standards (17)
PN-77/C-04584
PN-82/C-04576.08
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2
PN-EN ISO 5815-1:2019-12
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11 PN-77/C-04584
PN-ISO 5667-4:2017-10 z wyłączeniem pkt. 13
PN-ISO 9280:2002
PN-ISO 9297:1994
Procedura badawcza PB-ZLŚ-28, wydanie 4 z dnia 13.03.2025