{"lab":{"_id":"69ad52a3de79e566650fb6da","accr_number":"AB 1338","country":"PL","accr_body":"PCA","address":"DZIAŁ JAKOŚCI, LABORATORIUM OCHRONY ŚRODOWISKA, ul. Fabryczna 4, 88-101 Inowrocław","categories":["water"],"city":"Inowrocław","imported_at":"2026-03-08T10:42:43.265Z","methods_count":16,"name":"QEMETICA Soda Polska S.A.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1338.pdf"],"scope_summary":"","search_text":"qemetica soda polska s.a. dział jakości, laboratorium ochrony środowiska, ul. fabryczna 4, 88-101 inowrocław environment other water pharma electronics","status":"active","updated_at":"2026-03-08T14:50:30.714Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:30.714Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201338,podmiot.html","parse_date":"2026-07-17T16:19:04.042Z","parse_source":"m5-mistral-qa","fields_of_testing":[{"codes":"C/28/P; C/30/P;C/33/P","pl":"Badania chemiczne i pobieranie próbek wody i ścieków/Chemical tests and sampling of water and sewage Badania chemiczne i pobieranie próbek – środowisko pracy (czynniki szkodliwe – powietrze)","en":"Chemical tests and sampling of – working environment (harmful factors – air),"},{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) środowisko pracy (czynniki szkodliwe i uciążliwe – hałas)","en":"Tests concerning environmental engineering (environmental and climatic) – working environment (harmful and nuisance factors – noise)"},{"codes":"N/28/P; N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody i ścieków","en":"Tests of physical properties and sampling of water and sewage Badania właściwości fizycznych i pobieranie próbek – środowisko pracy (czynniki szkodliwe – powie-"},{"codes":"N/33/P","pl":"trze)//Tests of physical properties and sampling of- working environment (harmful factors – air), Pobieranie próbek – środowisko pracy (czynniki szkodliwe – powietrze)","en":"Sampling – working environment"},{"codes":"P/33","pl":"(harmful factors – air)","en":""}],"issue":{"no":"19","date":"19.05.2025"},"map_coord":[52.749821,18.254319],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":16},"category_scores":{"water":16},"has_zh":true},"methods":[{"_id":"6a5a55f89af9f73f382522d7","lab_id":"69ad52a3de79e566650fb6da","country":"PL","accr_number":"AB 1338","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna Temperatura pobranej próbki wody Zakres: (1,0 - 50)°C","methodology_en":"Sampling for chemical and physical testing Manual method Temperature of the water sample taken Range: (1,0 - 50)°C","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna Temperatura pobranej próbki wody Zakres: (1,0 - 50)°C","reference":"PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2 | PN-ISO 5667-4:2017-10 z wyłączeniem pkt. 13 | PN-77/C-04584","norm_bases":["PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2","PN-ISO 5667-4:2017-10 z wyłączeniem pkt. 13","PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna Temperatura pobranej próbki wody Zakres: (1,0 - 50)°C PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2 | PN-ISO 5667-4:2017-10 z wyłączeniem pkt. 13 | PN-77/C-04584 Woda Pobieranie probek do badan chemicznych i fizycznych Metoda manualna Temperatura pobranej probki wody Zakres: (1,0 - 50)°C PN-EN ISO 5667-6:2016-12 z wylaczeniem pkt. 7.2 | PN-ISO 5667-4:2017-10 z wylaczeniem pkt. 13 | PN-77/C-04584","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Sampling for chemical and physical testing Manual method Temperature of the water sample taken Range: (1,0 - 50)°C PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2 | PN-ISO 5667-4:2017-10 z wyłączeniem pkt. 13 | PN-77/C-04584","search_zh":"水 PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2 | PN-ISO 5667-4:2017-10 z wyłączeniem pkt. 13 | PN-77/C-04584","test_object_zh":"水"},{"_id":"6a5a55f89af9f73f382522d8","lab_id":"69ad52a3de79e566650fb6da","country":"PL","accr_number":"AB 1338","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie azotu azotynowego Zakres: (0,01 - 0,25) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrite nitrogen concentration Range: (0,01 - 0,25) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego Zakres: (0,01 - 0,25) mg/l Metoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie azotu azotynowego Zakres: (0,01 - 0,25) mg/l Metoda spektrofotometryczna PN-EN 26777:1999 Woda Stezenie azotu azotynowego Zakres: (0,01 - 0,25) mg/l Metoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Nitrite nitrogen concentration Range: (0,01 - 0,25) mg/l Spectrophotometric method PN-EN 26777:1999","search_zh":"水 PN-EN 26777:1999","test_object_zh":"水"},{"_id":"6a5a55f89af9f73f382522d9","lab_id":"69ad52a3de79e566650fb6da","country":"PL","accr_number":"AB 1338","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna Metoda automatyczna Temperatura ścieków / pobranej próbki ścieków Zakres: (1,0 - 50)°C","methodology_en":"Sampling for chemical and physical testing Manual method Automatic method Temperature of wastewater / of the wastewater sample taken Range: (1,0 - 50)°C","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna Metoda automatyczna Temperatura ścieków / pobranej próbki ścieków Zakres: (1,0 - 50)°C","reference":"PN-ISO 5667-10:2021-11 PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11 PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna Metoda automatyczna Temperatura ścieków / pobranej próbki ścieków Zakres: (1,0 - 50)°C PN-ISO 5667-10:2021-11 PN-77/C-04584 Scieki Pobieranie probek do badan chemicznych i fizycznych Metoda manualna Metoda automatyczna Temperatura sciekow / pobranej probki sciekow Zakres: (1,0 - 50)°C PN-ISO 5667-10:2021-11 PN-77/C-04584","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Sampling for chemical and physical testing Manual method Automatic method Temperature of wastewater / of the wastewater sample taken Range: (1,0 - 50)°C PN-ISO 5667-10:2021-11 PN-77/C-04584","search_zh":"污水 PN-ISO 5667-10:2021-11 PN-77/C-04584","test_object_zh":"污水"},{"_id":"6a5a55f89af9f73f382522da","lab_id":"69ad52a3de79e566650fb6da","country":"PL","accr_number":"AB 1338","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu azotynowego Zakres: (0,01 - 10,0) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrite nitrogen concentration Range: (0,01 - 10,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego Zakres: (0,01 - 10,0) mg/l Metoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu azotynowego Zakres: (0,01 - 10,0) mg/l Metoda spektrofotometryczna PN-EN 26777:1999 Scieki Stezenie azotu azotynowego Zakres: (0,01 - 10,0) mg/l Metoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Nitrite nitrogen concentration Range: (0,01 - 10,0) mg/l Spectrophotometric method PN-EN 26777:1999","search_zh":"污水 PN-EN 26777:1999","test_object_zh":"污水"},{"_id":"6a5a55f89af9f73f382522db","lab_id":"69ad52a3de79e566650fb6da","country":"PL","accr_number":"AB 1338","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"pH Zakres: 2,0 – 12,0 Metoda potencjometryczna","methodology_en":"pH Range: 2,0 – 12,0 Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH Zakres: 2,0 – 12,0 Metoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki pH Zakres: 2,0 – 12,0 Metoda potencjometryczna PN-EN ISO 10523:2012 Woda, scieki pH Zakres: 2,0 – 12,0 Metoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater pH Range: 2,0 – 12,0 Potentiometric method PN-EN ISO 10523:2012","search_zh":"水、废水 pH 范围：2,0 – 12,0 电位法 PN-EN ISO 10523:2012","test_object_zh":"水、废水","methodology_zh":"pH 范围：2,0 – 12,0 电位法"},{"_id":"6a5a55f89af9f73f382522dc","lab_id":"69ad52a3de79e566650fb6da","country":"PL","accr_number":"AB 1338","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie siarczanów Zakres: (10 - 1000) mg/l Metoda wagowa","methodology_en":"Sulfate concentration Range: (10 - 1000) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie siarczanów Zakres: (10 - 1000) mg/l Metoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie siarczanów Zakres: (10 - 1000) mg/l Metoda wagowa PN-ISO 9280:2002 Woda, scieki Stezenie siarczanow Zakres: (10 - 1000) mg/l Metoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Sulfate concentration Range: (10 - 1000) mg/l Gravimetric method PN-ISO 9280:2002","search_zh":"水、废水 PN-ISO 9280:2002","test_object_zh":"水、废水"},{"_id":"6a5a55f89af9f73f382522dd","lab_id":"69ad52a3de79e566650fb6da","country":"PL","accr_number":"AB 1338","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu amonowego Zakres: (0,2 - 1000) mg/l Metoda miareczkowa","methodology_en":"Ammonium nitrogen concentration Range: (0,2 - 1000) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego Zakres: (0,2 - 1000) mg/l Metoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu amonowego Zakres: (0,2 - 1000) mg/l Metoda miareczkowa PN-ISO 5664:2002 Woda, scieki Stezenie azotu amonowego Zakres: (0,2 - 1000) mg/l Metoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Ammonium nitrogen concentration Range: (0,2 - 1000) mg/l Titrimetric method PN-ISO 5664:2002","search_zh":"水、废水 PN-ISO 5664:2002","test_object_zh":"水、废水"},{"_id":"6a5a55f89af9f73f382522de","lab_id":"69ad52a3de79e566650fb6da","country":"PL","accr_number":"AB 1338","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu Kjeldahla Zakres: (1 - 100) mg/l Metoda miareczkowa","methodology_en":"Kjeldahl nitrogen concentration Range: (1 - 100) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla Zakres: (1 - 100) mg/l Metoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu Kjeldahla Zakres: (1 - 100) mg/l Metoda miareczkowa PN-EN 25663:2001 Woda, scieki Stezenie azotu Kjeldahla Zakres: (1 - 100) mg/l Metoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Kjeldahl nitrogen concentration Range: (1 - 100) mg/l Titrimetric method PN-EN 25663:2001","search_zh":"水、废水 PN-EN 25663:2001","test_object_zh":"水、废水"},{"_id":"6a5a55f89af9f73f382522df","lab_id":"69ad52a3de79e566650fb6da","country":"PL","accr_number":"AB 1338","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenia azotu azotanowego Zakres: (0,1 - 50) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrate nitrogen concentrations Range: (0,1 - 50) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenia azotu azotanowego Zakres: (0,1 - 50) mg/l Metoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenia azotu azotanowego Zakres: (0,1 - 50) mg/l Metoda spektrofotometryczna PN-82/C-04576.08 Woda, scieki Stezenia azotu azotanowego Zakres: (0,1 - 50) mg/l Metoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Nitrate nitrogen concentrations Range: (0,1 - 50) mg/l Spectrophotometric method PN-82/C-04576.08","search_zh":"水、废水 PN-82/C-04576.08","test_object_zh":"水、废水"},{"_id":"6a5a55f89af9f73f382522e0","lab_id":"69ad52a3de79e566650fb6da","country":"PL","accr_number":"AB 1338","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie chlorków Zakres: (5 - 75000) mg/l Metoda miareczkowa","methodology_en":"Chloride concentration Range: (5 - 75000) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chlorków Zakres: (5 - 75000) mg/l Metoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie chlorków Zakres: (5 - 75000) mg/l Metoda miareczkowa PN-ISO 9297:1994 Woda, scieki Stezenie chlorkow Zakres: (5 - 75000) mg/l Metoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Chloride concentration Range: (5 - 75000) mg/l Titrimetric method PN-ISO 9297:1994","search_zh":"水、废水 PN-ISO 9297:1994","test_object_zh":"水、废水"},{"_id":"6a5a55f89af9f73f382522e1","lab_id":"69ad52a3de79e566650fb6da","country":"PL","accr_number":"AB 1338","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu ogólnego (z obliczeń)","methodology_en":"Total nitrogen concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"Procedura badawcza PB-ZLŚ-28, wydanie 4 z dnia 13.03.2025","norm_bases":["Procedura badawcza PB-ZLŚ-28, wydanie 4 z dnia 13.03.2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu ogólnego (z obliczeń) Procedura badawcza PB-ZLŚ-28, wydanie 4 z dnia 13.03.2025 Woda, scieki Stezenie azotu ogolnego (z obliczen) Procedura badawcza PB-ZLS-28, wydanie 4 z dnia 13.03.2025","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Total nitrogen concentration (calculated) Procedura badawcza PB-ZLŚ-28, wydanie 4 z dnia 13.03.2025","methodology_zh":"总氮浓度（计算值）","search_zh":"水、废水 总氮浓度（计算值） Procedura badawcza PB-ZLŚ-28, wydanie 4 z dnia 13.03.2025","test_object_zh":"水、废水"},{"_id":"6a5a55f89af9f73f382522e2","lab_id":"69ad52a3de79e566650fb6da","country":"PL","accr_number":"AB 1338","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Zawiesiny ogólne Zakres: (2,0 - 1000) mg/l Metoda wagowa","methodology_en":"Total suspended solids Range: (2,0 - 1000) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawiesiny ogólne Zakres: (2,0 - 1000) mg/l Metoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Zawiesiny ogólne Zakres: (2,0 - 1000) mg/l Metoda wagowa PN-EN 872:2007+Ap1:2007 Woda, scieki Zawiesiny ogolne Zakres: (2,0 - 1000) mg/l Metoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Total suspended solids Range: (2,0 - 1000) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007","search_zh":"水、废水 PN-EN 872:2007+Ap1:2007","test_object_zh":"水、废水"},{"_id":"6a5a55f89af9f73f382522e3","lab_id":"69ad52a3de79e566650fb6da","country":"PL","accr_number":"AB 1338","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Chemiczne zapotrzebowanie tlenu ChZT-Cr Zakres: (6,0 - 150) mg/l O2 Metoda spektrofotometryczna","methodology_en":"Chemical oxygen demand COD-Cr Range: (6,0 - 150) mg/l O2 Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu ChZT-Cr Zakres: (6,0 - 150) mg/l O2 Metoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu ChZT-Cr Zakres: (6,0 - 150) mg/l O2 Metoda spektrofotometryczna PN-ISO 15705:2005 Woda, scieki Chemiczne zapotrzebowanie tlenu ChZT-Cr Zakres: (6,0 - 150) mg/l O2 Metoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Chemical oxygen demand COD-Cr Range: (6,0 - 150) mg/l O2 Spectrophotometric method PN-ISO 15705:2005","search_zh":"水、废水 PN-ISO 15705:2005","test_object_zh":"水、废水"},{"_id":"6a5a55f89af9f73f382522e4","lab_id":"69ad52a3de79e566650fb6da","country":"PL","accr_number":"AB 1338","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (2,0 - 6,0) mg/l O 2 Metoda miareczkowa","methodology_en":"Biochemical oxygen demand - BOD 5 Range: (2,0 - 6,0) mg/l O 2 Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (2,0 - 6,0) mg/l O 2 Metoda miareczkowa","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (2,0 - 6,0) mg/l O 2 Metoda miareczkowa PN-EN 1899-2:2002 Woda, scieki Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (2,0 - 6,0) mg/l O 2 Metoda miareczkowa PN-EN 1899-2:2002","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Biochemical oxygen demand - BOD 5 Range: (2,0 - 6,0) mg/l O 2 Titrimetric method PN-EN 1899-2:2002","search_zh":"水、废水 PN-EN 1899-2:2002","test_object_zh":"水、废水"},{"_id":"6a5a55f89af9f73f382522e5","lab_id":"69ad52a3de79e566650fb6da","country":"PL","accr_number":"AB 1338","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (3 - 100) mg/l O 2 Metoda miareczkowa","methodology_en":"Biochemical oxygen demand - BOD 5 Range: (3 - 100) mg/l O 2 Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (3 - 100) mg/l O 2 Metoda miareczkowa","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (3 - 100) mg/l O 2 Metoda miareczkowa PN-EN ISO 5815-1:2019-12 Woda, scieki Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (3 - 100) mg/l O 2 Metoda miareczkowa PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Biochemical oxygen demand - BOD 5 Range: (3 - 100) mg/l O 2 Titrimetric method PN-EN ISO 5815-1:2019-12","search_zh":"水、废水 PN-EN ISO 5815-1:2019-12","test_object_zh":"水、废水"},{"_id":"6a5a55f89af9f73f382522e6","lab_id":"69ad52a3de79e566650fb6da","country":"PL","accr_number":"AB 1338","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Przewodność elektryczna właściwa Zakres: (200 – 200000) µS/cm Metoda konduktometryczna","methodology_en":"Electrical conductivity Range: (200 – 200000) µS/cm Conductometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa Zakres: (200 – 200000) µS/cm Metoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Przewodność elektryczna właściwa Zakres: (200 – 200000) µS/cm Metoda konduktometryczna PN-EN 27888:1999 Woda, scieki Przewodnosc elektryczna wlasciwa Zakres: (200 – 200000) µS/cm Metoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Electrical conductivity Range: (200 – 200000) µS/cm Conductometric method PN-EN 27888:1999","search_zh":"水、废水 PN-EN 27888:1999","test_object_zh":"水、废水"}],"has_pdf":true}