🇵🇱 UNI-NET POLAND SP. Z O.O. PL
EnvironmentElectronics & EMCMaterials & polymers
UNI-NET POLAND SP. Z O.O. is a laboratory accredited by PCA under number AB 1333 (Warszawa, Poland). Its accreditation scope covers 17 test methods in the following areas: Environment, Electronics & EMC, Materials & polymers. Test objects include: Środowisko pracy − pole elektromagnetyczne pochodzące od instalacji…, Environment - electromagnetic field in the vicinity of radiocommuni…, Workplace environment - electromagnetic field from transmitting dev…, Workplace environment − electromagnetic field from equipment used i…. Most frequently used techniques: Direct measurement method, Direct measurement method (simplified).
At a glance
- Accreditation number: PCA AB 1333
- Methods in scope: 17
- Types of test objects: 6
- Techniques used: 2
- City: Warszawa, Poland
- Accreditation number
- AB 1333
- Accreditation body
- PCA
- Address
- LABORATORIUM BADAWCZE, ul. Bruzdowa 94A, 02-991 Warszawa
- City
- Warszawa, Poland
What this laboratory tests (6)
- Środowisko pracy − pole elektromagnetyczne pochodzące od instalacji i urządzeń przemysłowych: - piece oporowe i łukowe - przemysłowe piece, nagrzewnice i suszarki mikrofalowe, - urządzenia do grzania dielektrycznego - urządzenia do grzania indukcyjnego - urządzenia do wytwarzania i przetwarzania tworzyw sztucznych - elektrodrążarki - urządzenia specjalne - urządzenia do wykrywania metalu — 4 methods
- Environment - electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) — 3 methods
- Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (mobile telephony base stations; broadcasting and radiocommunication systems - radio, television, etc.) — 3 methods
- Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units — 3 methods
- Workplace environment − electromagnetic field from radiocommunication and anti-theft systems: - hand-held and cordless radiotelephones, short-range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - anti-theft and electronic article surveillance systems — 3 methods
- Workplace environment - electromagnetic field from magnetotherapy equipment — 1 method
Analytical techniques used (2)
- Direct measurement method — 11 methods
- Direct measurement method (simplified) — 1 method
Laboratory locations
- LABORATORIUM BADAWCZE — ul. Bruzdowa 94A
Accreditation scope — test methods (17)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Testing Laboratory | |||||
| 1 | Środowisko pracy − pole elektromagnetyczne pochodzące od instalacji i urządzeń przemysłowych: - piece oporowe i łukowe - przemysłowe piece, nagrzewnice i suszarki mikrofalowe, - urządzenia do grzania dielektrycznego - urządzenia do grzania indukcyjnego - urządzenia do wytwarzania i przetwarzania tworzyw sztucznych - elektrodrążarki - urządzenia specjalne - urządzenia do wykrywania metalu | Electric field strength: w zakresie częstotliwości od 20 Hz do 400 kHz Zakres: 1 V/m – 25 kV/m w zakresie częstotliwości od 100 kHz do 800 MHz Zakres: (1,0 – 1000) V/m w zakresie częstotliwości od 800 GHz do 90 GHz Zakres: (0,8 – 300) V/m |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r. | |
| 2 | Środowisko pracy − pole elektromagnetyczne pochodzące od instalacji i urządzeń przemysłowych: - piece oporowe i łukowe - przemysłowe piece, nagrzewnice i suszarki mikrofalowe, - urządzenia do grzania dielektrycznego - urządzenia do grzania indukcyjnego - urządzenia do wytwarzania i przetwarzania tworzyw sztucznych - elektrodrążarki - urządzenia specjalne - urządzenia do wykrywania metalu | Magnetic field strength: w zakresie częstotliwości od 100 kHz do 40 MHz Zakres: (0,02 – 16,0) A/m w zakresie częstotliwości od 20 MHz do 1 GHz Zakres: (0,02 – 1,2) A/m |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r. | |
| 3 | Środowisko pracy − pole elektromagnetyczne pochodzące od instalacji i urządzeń przemysłowych: - piece oporowe i łukowe - przemysłowe piece, nagrzewnice i suszarki mikrofalowe, - urządzenia do grzania dielektrycznego - urządzenia do grzania indukcyjnego - urządzenia do wytwarzania i przetwarzania tworzyw sztucznych - elektrodrążarki - urządzenia specjalne - urządzenia do wykrywania metalu | Magnetic flux density: w zakresie częstotliwości od 20 Hz do 400 kHz Zakres: 1 µT – 10 mT |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r. | |
| 4 | Środowisko pracy − pole elektromagnetyczne pochodzące od instalacji i urządzeń przemysłowych: - piece oporowe i łukowe - przemysłowe piece, nagrzewnice i suszarki mikrofalowe, - urządzenia do grzania dielektrycznego - urządzenia do grzania indukcyjnego - urządzenia do wytwarzania i przetwarzania tworzyw sztucznych - elektrodrążarki - urządzenia specjalne - urządzenia do wykrywania metalu | Magnetic field strength: w zakresie częstotliwości od 20 Hz do 400 kHz w zakresie częstotliwości od 800 MHz – 90 GHz (z obliczeń) |
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r. | ||
| 5 | Workplace environment − electromagnetic field from radiocommunication and anti-theft systems: - hand-held and cordless radiotelephones, short-range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - anti-theft and electronic article surveillance systems | Electric field strength: w zakresie częstotliwości od 200 kHz do 3 GHz Zakres: (1,0 – 1000) V/m w zakresie częstotliwości od 3 GHz do 90 GHz Zakres: (0,8 – 300) V/m |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r. | |
| 6 | Workplace environment − electromagnetic field from radiocommunication and anti-theft systems: - hand-held and cordless radiotelephones, short-range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - anti-theft and electronic article surveillance systems | Magnetic field strength: w zakresie częstotliwości od 200 kHz do 40 MHz Zakres: (0,02 – 16,0) A/m w zakresie częstotliwości od 20 MHz do 1 GHz Zakres: (0,02 – 1,2) A/m |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r. | |
| 7 | Workplace environment − electromagnetic field from radiocommunication and anti-theft systems: - hand-held and cordless radiotelephones, short-range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - anti-theft and electronic article surveillance systems | Magnetic field strength: w zakresie częstotliwości od 800 MHz – 90 GHz (z obliczeń) |
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r. | ||
| 8 | Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units | Electric field strength: w zakresie częstotliwości od 200 kHz do 3 GHz Zakres: (1,0 – 1000) V/m w zakresie częstotliwości od 3 GHz do 90 GHz Zakres: (0,8 – 300) V/m |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r. | |
| 9 | Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units | Magnetic field strength: w zakresie częstotliwości od 200 kHz do 40 MHz Zakres: (0,02 – 16,0) A/m w zakresie częstotliwości od 20 MHz do 1 GHz Zakres: (0,02 – 1,2) A/m |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r. | |
| 10 | Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units | Magnetic field strength: w zakresie częstotliwości od 800 MHz – 90 GHz (z obliczeń) |
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r. | ||
| 11 | Environment - electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) | Electric field strength: w zakresie częstotliwości od 200 kHz do 3 GHz Zakres: (0,8 – 1000) V/m w zakresie częstotliwości od 3 GHz do 90 GHz Zakres: (0,8 – 300) V/m Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17 lutego 2020 r. (Dz.U. 2022 poz. 2630) | |
| 12 | Environment - electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) | Magnetic field strength: w zakresie częstotliwości od 200 kHz do 40 MHz Zakres: (0,02 – 16) A/m Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17 lutego 2020 r. (Dz.U. 2022 poz. 2630) | |
| 13 | Environment - electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) | Magnetic field strength: w zakresie częstotliwości od 10 MHz do 90 GHz (z obliczeń) Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | ||
| 14 | Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (mobile telephony base stations; broadcasting and radiocommunication systems - radio, television, etc.) | Electric field strength: w zakresie częstotliwości od 100 kHz do 3 GHz Zakres: (0,8 – 1000) V/m w zakresie częstotliwości od 3 GHz do 90 GHz Zakres: (0,8 – 300) V/m Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331). |
Direct measurement method | Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131 | |
| 15 | Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (mobile telephony base stations; broadcasting and radiocommunication systems - radio, television, etc.) | Magnetic field strength: w zakresie częstotliwości od 100 kHz do 40 MHz Zakres: (0,01 – 16,0) A/m w zakresie częstotliwości od 20 MHz do 800 MHz Zakres: (0,02 – 1,2) A/m Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331). |
Direct measurement method | Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131 | |
| 16 | Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (mobile telephony base stations; broadcasting and radiocommunication systems - radio, television, etc.) | Magnetic field strength: w zakresie częstotliwości od 800 MHz do 90 GHz (z obliczeń) Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331). |
Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131 | ||
| 17 | Workplace environment - electromagnetic field from magnetotherapy equipment | Magnetic flux density: w zakresie częstotliwości od 20 Hz do 50 Hz Zakres: 1µT – 10,0 mT Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331). |
Direct measurement method (simplified) | Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180 | |
Reference standards (6)
P-14 wydanie 16 z dnia 24.04.2026 r.
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180
Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131
Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
Załącznik do Rozporządzenia Ministra Klimatu z dnia 17 lutego 2020 r. (Dz.U. 2022 poz. 2630)