🇵🇱 UNI-NET POLAND SP. Z O.O. PL

PCA AB 1333 • Warszawa, Poland • 17 methods

EnvironmentElectronics & EMCMaterials & polymers

UNI-NET POLAND SP. Z O.O. is a laboratory accredited by PCA under number AB 1333 (Warszawa, Poland). Its accreditation scope covers 17 test methods in the following areas: Environment, Electronics & EMC, Materials & polymers. Test objects include: Środowisko pracy − pole elektromagnetyczne pochodzące od instalacji…, Environment - electromagnetic field in the vicinity of radiocommuni…, Workplace environment - electromagnetic field from transmitting dev…, Workplace environment − electromagnetic field from equipment used i…. Most frequently used techniques: Direct measurement method, Direct measurement method (simplified).

At a glance

  • Accreditation number: PCA AB 1333
  • Methods in scope: 17
  • Types of test objects: 6
  • Techniques used: 2
  • City: Warszawa, Poland
Accreditation number
AB 1333
Accreditation body
PCA
Address
LABORATORIUM BADAWCZE, ul. Bruzdowa 94A, 02-991 Warszawa
City
Warszawa, Poland

What this laboratory tests (6)

Analytical techniques used (2)

Laboratory locations

Accreditation scope — test methods (17)

No. Test object Methodology / Parameters Technique Reference document
Testing Laboratory
1 Środowisko pracy − pole elektromagnetyczne pochodzące od instalacji i urządzeń przemysłowych: - piece oporowe i łukowe - przemysłowe piece, nagrzewnice i suszarki mikrofalowe, - urządzenia do grzania dielektrycznego - urządzenia do grzania indukcyjnego - urządzenia do wytwarzania i przetwarzania tworzyw sztucznych - elektrodrążarki - urządzenia specjalne - urządzenia do wykrywania metalu Electric field strength:
w zakresie częstotliwości od 20 Hz do 400 kHz Zakres: 1 V/m – 25 kV/m w zakresie częstotliwości od 100 kHz do 800 MHz Zakres: (1,0 – 1000) V/m w zakresie częstotliwości od 800 GHz do 90 GHz Zakres: (0,8 – 300) V/m
Direct measurement method PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r.
2 Środowisko pracy − pole elektromagnetyczne pochodzące od instalacji i urządzeń przemysłowych: - piece oporowe i łukowe - przemysłowe piece, nagrzewnice i suszarki mikrofalowe, - urządzenia do grzania dielektrycznego - urządzenia do grzania indukcyjnego - urządzenia do wytwarzania i przetwarzania tworzyw sztucznych - elektrodrążarki - urządzenia specjalne - urządzenia do wykrywania metalu Magnetic field strength:
w zakresie częstotliwości od 100 kHz do 40 MHz Zakres: (0,02 – 16,0) A/m w zakresie częstotliwości od 20 MHz do 1 GHz Zakres: (0,02 – 1,2) A/m
Direct measurement method PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r.
3 Środowisko pracy − pole elektromagnetyczne pochodzące od instalacji i urządzeń przemysłowych: - piece oporowe i łukowe - przemysłowe piece, nagrzewnice i suszarki mikrofalowe, - urządzenia do grzania dielektrycznego - urządzenia do grzania indukcyjnego - urządzenia do wytwarzania i przetwarzania tworzyw sztucznych - elektrodrążarki - urządzenia specjalne - urządzenia do wykrywania metalu Magnetic flux density:
w zakresie częstotliwości od 20 Hz do 400 kHz Zakres: 1 µT – 10 mT
Direct measurement method PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r.
4 Środowisko pracy − pole elektromagnetyczne pochodzące od instalacji i urządzeń przemysłowych: - piece oporowe i łukowe - przemysłowe piece, nagrzewnice i suszarki mikrofalowe, - urządzenia do grzania dielektrycznego - urządzenia do grzania indukcyjnego - urządzenia do wytwarzania i przetwarzania tworzyw sztucznych - elektrodrążarki - urządzenia specjalne - urządzenia do wykrywania metalu Magnetic field strength:
w zakresie częstotliwości od 20 Hz do 400 kHz w zakresie częstotliwości od 800 MHz – 90 GHz (z obliczeń)
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r.
5 Workplace environment − electromagnetic field from radiocommunication and anti-theft systems: - hand-held and cordless radiotelephones, short-range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - anti-theft and electronic article surveillance systems Electric field strength:
w zakresie częstotliwości od 200 kHz do 3 GHz Zakres: (1,0 – 1000) V/m w zakresie częstotliwości od 3 GHz do 90 GHz Zakres: (0,8 – 300) V/m
Direct measurement method PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r.
6 Workplace environment − electromagnetic field from radiocommunication and anti-theft systems: - hand-held and cordless radiotelephones, short-range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - anti-theft and electronic article surveillance systems Magnetic field strength:
w zakresie częstotliwości od 200 kHz do 40 MHz Zakres: (0,02 – 16,0) A/m w zakresie częstotliwości od 20 MHz do 1 GHz Zakres: (0,02 – 1,2) A/m
Direct measurement method PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r.
7 Workplace environment − electromagnetic field from radiocommunication and anti-theft systems: - hand-held and cordless radiotelephones, short-range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - anti-theft and electronic article surveillance systems Magnetic field strength:
w zakresie częstotliwości od 800 MHz – 90 GHz (z obliczeń)
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r.
8 Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units Electric field strength:
w zakresie częstotliwości od 200 kHz do 3 GHz Zakres: (1,0 – 1000) V/m w zakresie częstotliwości od 3 GHz do 90 GHz Zakres: (0,8 – 300) V/m
Direct measurement method PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r.
9 Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units Magnetic field strength:
w zakresie częstotliwości od 200 kHz do 40 MHz Zakres: (0,02 – 16,0) A/m w zakresie częstotliwości od 20 MHz do 1 GHz Zakres: (0,02 – 1,2) A/m
Direct measurement method PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r.
10 Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units Magnetic field strength:
w zakresie częstotliwości od 800 MHz – 90 GHz (z obliczeń)
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r.
11 Environment - electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Electric field strength:
w zakresie częstotliwości od 200 kHz do 3 GHz Zakres: (0,8 – 1000) V/m w zakresie częstotliwości od 3 GHz do 90 GHz Zakres: (0,8 – 300) V/m
Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Direct measurement method Załącznik do Rozporządzenia Ministra Klimatu z dnia 17 lutego 2020 r. (Dz.U. 2022 poz. 2630)
12 Environment - electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Magnetic field strength:
w zakresie częstotliwości od 200 kHz do 40 MHz Zakres: (0,02 – 16) A/m
Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Direct measurement method Załącznik do Rozporządzenia Ministra Klimatu z dnia 17 lutego 2020 r. (Dz.U. 2022 poz. 2630)
13 Environment - electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Magnetic field strength:
w zakresie częstotliwości od 10 MHz do 90 GHz (z obliczeń)
Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
14 Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (mobile telephony base stations; broadcasting and radiocommunication systems - radio, television, etc.) Electric field strength:
w zakresie częstotliwości od 100 kHz do 3 GHz Zakres: (0,8 – 1000) V/m w zakresie częstotliwości od 3 GHz do 90 GHz Zakres: (0,8 – 300) V/m
Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331).
Direct measurement method Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131
15 Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (mobile telephony base stations; broadcasting and radiocommunication systems - radio, television, etc.) Magnetic field strength:
w zakresie częstotliwości od 100 kHz do 40 MHz Zakres: (0,01 – 16,0) A/m w zakresie częstotliwości od 20 MHz do 800 MHz Zakres: (0,02 – 1,2) A/m
Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331).
Direct measurement method Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131
16 Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (mobile telephony base stations; broadcasting and radiocommunication systems - radio, television, etc.) Magnetic field strength:
w zakresie częstotliwości od 800 MHz do 90 GHz (z obliczeń)
Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331).
Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131
17 Workplace environment - electromagnetic field from magnetotherapy equipment Magnetic flux density:
w zakresie częstotliwości od 20 Hz do 50 Hz Zakres: 1µT – 10,0 mT
Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331).
Direct measurement method (simplified) Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180

Reference standards (6)

P-14 wydanie 16 z dnia 24.04.2026 r.
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180
Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131
Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
Załącznik do Rozporządzenia Ministra Klimatu z dnia 17 lutego 2020 r. (Dz.U. 2022 poz. 2630)