{"lab":{"_id":"69ad52a3de79e566650fb6d2","accr_number":"AB 1333","country":"PL","accr_body":"PCA","address":"LABORATORIUM BADAWCZE, ul. Bruzdowa 94A, 02-991 Warszawa","categories":["environment","materials","electronics"],"city":"Warszawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":17,"name":"UNI-NET POLAND SP. Z O.O.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1333.pdf"],"scope_summary":"","search_text":"uni-net poland sp. z o.o. laboratorium badawcze, ul. bruzdowa 94a, 02-991 warszawa environment pharma electronics other metrology","status":"active","updated_at":"2026-03-08T14:50:30.360Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T10:13:03.121Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201333,podmiot.html","parse_date":"2026-08-17T10:13:03.121Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe – pole elektromagnetyczne)","en":"Tests concerning environmental engineering (environmental and climatic) – working environment (harmful factors – electromagnetic field)"},{"codes":"G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko ogólne (czynniki fizyczne – pole elektromagnetyczne)","en":"Tests concerning environmental engineering (environmental and climatic) – general environment (physical factors - electromagnetic field)"}],"issue":{"no":"19","date":"18.05.2026"},"map_coord":[52.170092,21.115216],"map_geo":"nominatim-street","lab_locations":[{"name":"LABORATORIUM BADAWCZE","address":"ul. Bruzdowa 94A","city":"Warszawa","postal":"02-991"}],"scope_format":"PCA::pracownie+siatka5","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/52ac3163a9716b8b96cc28d8d58b5751/AB%201333.pdf","has_en":true,"category_counts":{"environment":17,"materials":4,"electronics":3},"category_scores":{"environment":12.04,"materials":0.67,"electronics":0.38},"has_zh":true,"lab_locations_zh":[{"name":"检测实验室","address":"ul. Bruzdowa 94A","city":"Warszawa","postal":"02-991"}]},"methods":[{"_id":"6a82deaf884ede9a1b2c352f","lab_id":"69ad52a3de79e566650fb6d2","country":"PL","accr_number":"AB 1333","accr_body":"PCA","test_object":"Środowisko pracy − pole elektromagnetyczne pochodzące od instalacji i urządzeń przemysłowych: - piece oporowe i łukowe - przemysłowe piece, nagrzewnice i suszarki mikrofalowe, - urządzenia do grzania dielektrycznego - urządzenia do grzania indukcyjnego - urządzenia do wytwarzania i przetwarzania tworzyw sztucznych - elektrodrążarki - urządzenia specjalne - urządzenia do wykrywania metalu","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"w zakresie częstotliwości od 20 Hz do 400 kHz","range":"Zakres: 1 V/m – 25 kV/m"},{"name":"w zakresie częstotliwości od 100 kHz do 800 MHz","range":"Zakres: (1,0 – 1000) V/m"},{"name":"w zakresie częstotliwości od 800 GHz do 90 GHz","range":"Zakres: (0,8 – 300) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 20 Hz do 400 kHz Zakres: 1 V/m – 25 kV/m\nw zakresie częstotliwości od 100 kHz do 800 MHz Zakres: (1,0 – 1000) V/m\nw zakresie częstotliwości od 800 GHz do 90 GHz Zakres: (0,8 – 300) V/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r.","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","P-14 wydanie 16 z dnia 24.04.2026 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − pole elektromagnetyczne pochodzące od instalacji i urządzeń przemysłowych: - piece oporowe i łukowe - przemysłowe piece, nagrzewnice i suszarki mikrofalowe, - urządzenia do grzania dielektrycznego - urządzenia do grzania indukcyjnego - urządzenia do wytwarzania i przetwarzania tworzyw sztucznych - elektrodrążarki - urządzenia specjalne - urządzenia do wykrywania metalu Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 20 Hz do 400 kHz Zakres: 1 V/m – 25 kV/m\nw zakresie częstotliwości od 100 kHz do 800 MHz Zakres: (1,0 – 1000) V/m\nw zakresie częstotliwości od 800 GHz do 90 GHz Zakres: (0,8 – 300) V/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r. Srodowisko pracy − pole elektromagnetyczne pochodzace od instalacji i urzadzen przemyslowych: - piece oporowe i lukowe - przemyslowe piece, nagrzewnice i suszarki mikrofalowe, - urzadzenia do grzania dielektrycznego - urzadzenia do grzania indukcyjnego - urzadzenia do wytwarzania i przetwarzania tworzyw sztucznych - elektrodrazarki - urzadzenia specjalne - urzadzenia do wykrywania metalu Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 20 Hz do 400 kHz Zakres: 1 V/m – 25 kV/m\nw zakresie czestotliwosci od 100 kHz do 800 MHz Zakres: (1,0 – 1000) V/m\nw zakresie czestotliwosci od 800 GHz do 90 GHz Zakres: (0,8 – 300) V/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r.","categories":["materials","environment"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Electric field strength:","search_en":"Electric field strength: Direct measurement method Testing Laboratory PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r.","technique_en":"Direct measurement method","lab_section_zh":"检测实验室","methodology_zh":"电场强度：","search_zh":"电场强度： 直接测量法 检测实验室 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r.","technique_zh":"直接测量法"},{"_id":"6a82deaf884ede9a1b2c3530","lab_id":"69ad52a3de79e566650fb6d2","country":"PL","accr_number":"AB 1333","accr_body":"PCA","test_object":"Środowisko pracy − pole elektromagnetyczne pochodzące od instalacji i urządzeń przemysłowych: - piece oporowe i łukowe - przemysłowe piece, nagrzewnice i suszarki mikrofalowe, - urządzenia do grzania dielektrycznego - urządzenia do grzania indukcyjnego - urządzenia do wytwarzania i przetwarzania tworzyw sztucznych - elektrodrążarki - urządzenia specjalne - urządzenia do wykrywania metalu","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości od 100 kHz do 40 MHz","range":"Zakres: (0,02 – 16,0) A/m"},{"name":"w zakresie częstotliwości od 20 MHz do 1 GHz","range":"Zakres: (0,02 – 1,2) A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 100 kHz do 40 MHz Zakres: (0,02 – 16,0) A/m\nw zakresie częstotliwości od 20 MHz do 1 GHz Zakres: (0,02 – 1,2) A/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r.","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","P-14 wydanie 16 z dnia 24.04.2026 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − pole elektromagnetyczne pochodzące od instalacji i urządzeń przemysłowych: - piece oporowe i łukowe - przemysłowe piece, nagrzewnice i suszarki mikrofalowe, - urządzenia do grzania dielektrycznego - urządzenia do grzania indukcyjnego - urządzenia do wytwarzania i przetwarzania tworzyw sztucznych - elektrodrążarki - urządzenia specjalne - urządzenia do wykrywania metalu Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 100 kHz do 40 MHz Zakres: (0,02 – 16,0) A/m\nw zakresie częstotliwości od 20 MHz do 1 GHz Zakres: (0,02 – 1,2) A/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r. Srodowisko pracy − pole elektromagnetyczne pochodzace od instalacji i urzadzen przemyslowych: - piece oporowe i lukowe - przemyslowe piece, nagrzewnice i suszarki mikrofalowe, - urzadzenia do grzania dielektrycznego - urzadzenia do grzania indukcyjnego - urzadzenia do wytwarzania i przetwarzania tworzyw sztucznych - elektrodrazarki - urzadzenia specjalne - urzadzenia do wykrywania metalu Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 100 kHz do 40 MHz Zakres: (0,02 – 16,0) A/m\nw zakresie czestotliwosci od 20 MHz do 1 GHz Zakres: (0,02 – 1,2) A/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r.","categories":["materials","environment"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Magnetic field strength:","search_en":"Magnetic field strength: Direct measurement method Testing Laboratory PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r.","technique_en":"Direct measurement method","lab_section_zh":"检测实验室","methodology_zh":"磁场强度：","search_zh":"磁场强度： 直接测量法 检测实验室 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r.","technique_zh":"直接测量法"},{"_id":"6a82deaf884ede9a1b2c3531","lab_id":"69ad52a3de79e566650fb6d2","country":"PL","accr_number":"AB 1333","accr_body":"PCA","test_object":"Środowisko pracy − pole elektromagnetyczne pochodzące od instalacji i urządzeń przemysłowych: - piece oporowe i łukowe - przemysłowe piece, nagrzewnice i suszarki mikrofalowe, - urządzenia do grzania dielektrycznego - urządzenia do grzania indukcyjnego - urządzenia do wytwarzania i przetwarzania tworzyw sztucznych - elektrodrążarki - urządzenia specjalne - urządzenia do wykrywania metalu","methodology":"Indukcja magnetyczna:","parameters":[{"name":"w zakresie częstotliwości od 20 Hz do 400 kHz","range":"Zakres: 1 µT – 10 mT"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Indukcja magnetyczna:\nw zakresie częstotliwości od 20 Hz do 400 kHz Zakres: 1 µT – 10 mT\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r.","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","P-14 wydanie 16 z dnia 24.04.2026 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − pole elektromagnetyczne pochodzące od instalacji i urządzeń przemysłowych: - piece oporowe i łukowe - przemysłowe piece, nagrzewnice i suszarki mikrofalowe, - urządzenia do grzania dielektrycznego - urządzenia do grzania indukcyjnego - urządzenia do wytwarzania i przetwarzania tworzyw sztucznych - elektrodrążarki - urządzenia specjalne - urządzenia do wykrywania metalu Indukcja magnetyczna:\nw zakresie częstotliwości od 20 Hz do 400 kHz Zakres: 1 µT – 10 mT\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r. Srodowisko pracy − pole elektromagnetyczne pochodzace od instalacji i urzadzen przemyslowych: - piece oporowe i lukowe - przemyslowe piece, nagrzewnice i suszarki mikrofalowe, - urzadzenia do grzania dielektrycznego - urzadzenia do grzania indukcyjnego - urzadzenia do wytwarzania i przetwarzania tworzyw sztucznych - elektrodrazarki - urzadzenia specjalne - urzadzenia do wykrywania metalu Indukcja magnetyczna:\nw zakresie czestotliwosci od 20 Hz do 400 kHz Zakres: 1 µT – 10 mT\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r.","categories":["materials","environment"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Magnetic flux density:","search_en":"Magnetic flux density: Direct measurement method Testing Laboratory PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r.","technique_en":"Direct measurement method","lab_section_zh":"检测实验室","search_zh":"磁感应强度： 直接测量法 检测实验室 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r.","technique_zh":"直接测量法","methodology_zh":"磁感应强度："},{"_id":"6a82deaf884ede9a1b2c3532","lab_id":"69ad52a3de79e566650fb6d2","country":"PL","accr_number":"AB 1333","accr_body":"PCA","test_object":"Środowisko pracy − pole elektromagnetyczne pochodzące od instalacji i urządzeń przemysłowych: - piece oporowe i łukowe - przemysłowe piece, nagrzewnice i suszarki mikrofalowe, - urządzenia do grzania dielektrycznego - urządzenia do grzania indukcyjnego - urządzenia do wytwarzania i przetwarzania tworzyw sztucznych - elektrodrążarki - urządzenia specjalne - urządzenia do wykrywania metalu","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości od 20 Hz do 400 kHz"},{"name":"w zakresie częstotliwości od 800 MHz – 90 GHz (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 20 Hz do 400 kHz\nw zakresie częstotliwości od 800 MHz – 90 GHz (z obliczeń)","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r.","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","P-14 wydanie 16 z dnia 24.04.2026 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − pole elektromagnetyczne pochodzące od instalacji i urządzeń przemysłowych: - piece oporowe i łukowe - przemysłowe piece, nagrzewnice i suszarki mikrofalowe, - urządzenia do grzania dielektrycznego - urządzenia do grzania indukcyjnego - urządzenia do wytwarzania i przetwarzania tworzyw sztucznych - elektrodrążarki - urządzenia specjalne - urządzenia do wykrywania metalu Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 20 Hz do 400 kHz\nw zakresie częstotliwości od 800 MHz – 90 GHz (z obliczeń) PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r. Srodowisko pracy − pole elektromagnetyczne pochodzace od instalacji i urzadzen przemyslowych: - piece oporowe i lukowe - przemyslowe piece, nagrzewnice i suszarki mikrofalowe, - urzadzenia do grzania dielektrycznego - urzadzenia do grzania indukcyjnego - urzadzenia do wytwarzania i przetwarzania tworzyw sztucznych - elektrodrazarki - urzadzenia specjalne - urzadzenia do wykrywania metalu Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 20 Hz do 400 kHz\nw zakresie czestotliwosci od 800 MHz – 90 GHz (z obliczen) PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r.","categories":["materials","environment"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Magnetic field strength:","search_en":"Magnetic field strength: Testing Laboratory PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r.","lab_section_zh":"检测实验室","methodology_zh":"磁场强度：","search_zh":"磁场强度： 检测实验室 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r."},{"_id":"6a82deaf884ede9a1b2c3533","lab_id":"69ad52a3de79e566650fb6d2","country":"PL","accr_number":"AB 1333","accr_body":"PCA","test_object":"Środowisko pracy − pole elektromagnetyczne pochodzące od systemów radiokomunikacyjnych i antykradzieżowych: - radiotelefony doręczne, bezprzewodowe, terminale i urządzenia bezprzewodowe krótkiego zasięgu, radiostacje (radiotelefony) nasobne i przewoźne - systemy antykradzieżowe oraz elektronicznej kontroli obiektów","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"w zakresie częstotliwości od 200 kHz do 3 GHz","range":"Zakres: (1,0 – 1000) V/m"},{"name":"w zakresie częstotliwości od 3 GHz do 90 GHz","range":"Zakres: (0,8 – 300) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 200 kHz do 3 GHz Zakres: (1,0 – 1000) V/m\nw zakresie częstotliwości od 3 GHz do 90 GHz Zakres: (0,8 – 300) V/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r.","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","P-14 wydanie 16 z dnia 24.04.2026 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − pole elektromagnetyczne pochodzące od systemów radiokomunikacyjnych i antykradzieżowych: - radiotelefony doręczne, bezprzewodowe, terminale i urządzenia bezprzewodowe krótkiego zasięgu, radiostacje (radiotelefony) nasobne i przewoźne - systemy antykradzieżowe oraz elektronicznej kontroli obiektów Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 200 kHz do 3 GHz Zakres: (1,0 – 1000) V/m\nw zakresie częstotliwości od 3 GHz do 90 GHz Zakres: (0,8 – 300) V/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r. Srodowisko pracy − pole elektromagnetyczne pochodzace od systemow radiokomunikacyjnych i antykradziezowych: - radiotelefony doreczne, bezprzewodowe, terminale i urzadzenia bezprzewodowe krotkiego zasiegu, radiostacje (radiotelefony) nasobne i przewozne - systemy antykradziezowe oraz elektronicznej kontroli obiektow Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 200 kHz do 3 GHz Zakres: (1,0 – 1000) V/m\nw zakresie czestotliwosci od 3 GHz do 90 GHz Zakres: (0,8 – 300) V/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r.","categories":["environment","electronics"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Electric field strength:","search_en":"Workplace environment − electromagnetic field from radiocommunication and anti-theft systems: - hand-held and cordless radiotelephones, short-range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - anti-theft and electronic article surveillance systems Electric field strength: Direct measurement method Testing Laboratory PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r.","technique_en":"Direct measurement method","test_object_en":"Workplace environment − electromagnetic field from radiocommunication and anti-theft systems: - hand-held and cordless radiotelephones, short-range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - anti-theft and electronic article surveillance systems","lab_section_zh":"检测实验室","methodology_zh":"电场强度：","search_zh":"工作环境 － 无线电通信与防盗系统产生的电磁场：－ 手持对讲机、无绳设备、终端与设备 电场强度： 直接测量法 检测实验室 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r.","technique_zh":"直接测量法","test_object_zh":"工作环境 － 无线电通信与防盗系统产生的电磁场：－ 手持对讲机、无绳设备、终端与设备"},{"_id":"6a82deaf884ede9a1b2c3534","lab_id":"69ad52a3de79e566650fb6d2","country":"PL","accr_number":"AB 1333","accr_body":"PCA","test_object":"Środowisko pracy − pole elektromagnetyczne pochodzące od systemów radiokomunikacyjnych i antykradzieżowych: - radiotelefony doręczne, bezprzewodowe, terminale i urządzenia bezprzewodowe krótkiego zasięgu, radiostacje (radiotelefony) nasobne i przewoźne - systemy antykradzieżowe oraz elektronicznej kontroli obiektów","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości od 200 kHz do 40 MHz","range":"Zakres: (0,02 – 16,0) A/m"},{"name":"w zakresie częstotliwości od 20 MHz do 1 GHz","range":"Zakres: (0,02 – 1,2) A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 200 kHz do 40 MHz Zakres: (0,02 – 16,0) A/m\nw zakresie częstotliwości od 20 MHz do 1 GHz Zakres: (0,02 – 1,2) A/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r.","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","P-14 wydanie 16 z dnia 24.04.2026 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − pole elektromagnetyczne pochodzące od systemów radiokomunikacyjnych i antykradzieżowych: - radiotelefony doręczne, bezprzewodowe, terminale i urządzenia bezprzewodowe krótkiego zasięgu, radiostacje (radiotelefony) nasobne i przewoźne - systemy antykradzieżowe oraz elektronicznej kontroli obiektów Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 200 kHz do 40 MHz Zakres: (0,02 – 16,0) A/m\nw zakresie częstotliwości od 20 MHz do 1 GHz Zakres: (0,02 – 1,2) A/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r. Srodowisko pracy − pole elektromagnetyczne pochodzace od systemow radiokomunikacyjnych i antykradziezowych: - radiotelefony doreczne, bezprzewodowe, terminale i urzadzenia bezprzewodowe krotkiego zasiegu, radiostacje (radiotelefony) nasobne i przewozne - systemy antykradziezowe oraz elektronicznej kontroli obiektow Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 200 kHz do 40 MHz Zakres: (0,02 – 16,0) A/m\nw zakresie czestotliwosci od 20 MHz do 1 GHz Zakres: (0,02 – 1,2) A/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r.","categories":["environment","electronics"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Magnetic field strength:","search_en":"Workplace environment − electromagnetic field from radiocommunication and anti-theft systems: - hand-held and cordless radiotelephones, short-range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - anti-theft and electronic article surveillance systems Magnetic field strength: Direct measurement method Testing Laboratory PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r.","technique_en":"Direct measurement method","test_object_en":"Workplace environment − electromagnetic field from radiocommunication and anti-theft systems: - hand-held and cordless radiotelephones, short-range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - anti-theft and electronic article surveillance systems","lab_section_zh":"检测实验室","methodology_zh":"磁场强度：","search_zh":"工作环境 － 无线电通信与防盗系统产生的电磁场：－ 手持对讲机、无绳设备、终端与设备 磁场强度： 直接测量法 检测实验室 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r.","technique_zh":"直接测量法","test_object_zh":"工作环境 － 无线电通信与防盗系统产生的电磁场：－ 手持对讲机、无绳设备、终端与设备"},{"_id":"6a82deaf884ede9a1b2c3535","lab_id":"69ad52a3de79e566650fb6d2","country":"PL","accr_number":"AB 1333","accr_body":"PCA","test_object":"Środowisko pracy − pole elektromagnetyczne pochodzące od systemów radiokomunikacyjnych i antykradzieżowych: - radiotelefony doręczne, bezprzewodowe, terminale i urządzenia bezprzewodowe krótkiego zasięgu, radiostacje (radiotelefony) nasobne i przewoźne - systemy antykradzieżowe oraz elektronicznej kontroli obiektów","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości od 800 MHz – 90 GHz (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego:\nw zakresie częstotliwości od 800 MHz – 90 GHz (z obliczeń)","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r.","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","P-14 wydanie 16 z dnia 24.04.2026 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − pole elektromagnetyczne pochodzące od systemów radiokomunikacyjnych i antykradzieżowych: - radiotelefony doręczne, bezprzewodowe, terminale i urządzenia bezprzewodowe krótkiego zasięgu, radiostacje (radiotelefony) nasobne i przewoźne - systemy antykradzieżowe oraz elektronicznej kontroli obiektów Natężenie pola magnetycznego:\nw zakresie częstotliwości od 800 MHz – 90 GHz (z obliczeń) PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r. Srodowisko pracy − pole elektromagnetyczne pochodzace od systemow radiokomunikacyjnych i antykradziezowych: - radiotelefony doreczne, bezprzewodowe, terminale i urzadzenia bezprzewodowe krotkiego zasiegu, radiostacje (radiotelefony) nasobne i przewozne - systemy antykradziezowe oraz elektronicznej kontroli obiektow Natezenie pola magnetycznego:\nw zakresie czestotliwosci od 800 MHz – 90 GHz (z obliczen) PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r.","categories":["environment","electronics"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Magnetic field strength:","search_en":"Workplace environment − electromagnetic field from radiocommunication and anti-theft systems: - hand-held and cordless radiotelephones, short-range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - anti-theft and electronic article surveillance systems Magnetic field strength: Testing Laboratory PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r.","test_object_en":"Workplace environment − electromagnetic field from radiocommunication and anti-theft systems: - hand-held and cordless radiotelephones, short-range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - anti-theft and electronic article surveillance systems","lab_section_zh":"检测实验室","methodology_zh":"磁场强度：","search_zh":"工作环境 － 无线电通信与防盗系统产生的电磁场：－ 手持对讲机、无绳设备、终端与设备 磁场强度： 检测实验室 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r.","test_object_zh":"工作环境 － 无线电通信与防盗系统产生的电磁场：－ 手持对讲机、无绳设备、终端与设备"},{"_id":"6a82deaf884ede9a1b2c3536","lab_id":"69ad52a3de79e566650fb6d2","country":"PL","accr_number":"AB 1333","accr_body":"PCA","test_object":"Środowisko pracy − pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"w zakresie częstotliwości od 200 kHz do 3 GHz","range":"Zakres: (1,0 – 1000) V/m"},{"name":"w zakresie częstotliwości od 3 GHz do 90 GHz","range":"Zakres: (0,8 – 300) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 200 kHz do 3 GHz Zakres: (1,0 – 1000) V/m\nw zakresie częstotliwości od 3 GHz do 90 GHz Zakres: (0,8 – 300) V/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r.","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","P-14 wydanie 16 z dnia 24.04.2026 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 200 kHz do 3 GHz Zakres: (1,0 – 1000) V/m\nw zakresie częstotliwości od 3 GHz do 90 GHz Zakres: (0,8 – 300) V/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r. Srodowisko pracy − pole elektromagnetyczne pochodzace od urzadzen stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 200 kHz do 3 GHz Zakres: (1,0 – 1000) V/m\nw zakresie czestotliwosci od 3 GHz do 90 GHz Zakres: (0,8 – 300) V/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r.","categories":["environment"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Electric field strength:","search_en":"Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units Electric field strength: Direct measurement method Testing Laboratory PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r.","technique_en":"Direct measurement method","test_object_en":"Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units","lab_section_zh":"检测实验室","methodology_zh":"电场强度：","search_zh":"工作环境 － 医疗技术设备产生的电磁场：－ 外科电刀 － 理疗透热治疗仪 电场强度： 直接测量法 检测实验室 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r.","technique_zh":"直接测量法","test_object_zh":"工作环境 － 医疗技术设备产生的电磁场：－ 外科电刀 － 理疗透热治疗仪"},{"_id":"6a82deaf884ede9a1b2c3537","lab_id":"69ad52a3de79e566650fb6d2","country":"PL","accr_number":"AB 1333","accr_body":"PCA","test_object":"Środowisko pracy − pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości od 200 kHz do 40 MHz","range":"Zakres: (0,02 – 16,0) A/m"},{"name":"w zakresie częstotliwości od 20 MHz do 1 GHz","range":"Zakres: (0,02 – 1,2) A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 200 kHz do 40 MHz Zakres: (0,02 – 16,0) A/m\nw zakresie częstotliwości od 20 MHz do 1 GHz Zakres: (0,02 – 1,2) A/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r.","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","P-14 wydanie 16 z dnia 24.04.2026 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 200 kHz do 40 MHz Zakres: (0,02 – 16,0) A/m\nw zakresie częstotliwości od 20 MHz do 1 GHz Zakres: (0,02 – 1,2) A/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r. Srodowisko pracy − pole elektromagnetyczne pochodzace od urzadzen stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 200 kHz do 40 MHz Zakres: (0,02 – 16,0) A/m\nw zakresie czestotliwosci od 20 MHz do 1 GHz Zakres: (0,02 – 1,2) A/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r.","categories":["environment"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Magnetic field strength:","search_en":"Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units Magnetic field strength: Direct measurement method Testing Laboratory PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r.","technique_en":"Direct measurement method","test_object_en":"Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units","lab_section_zh":"检测实验室","methodology_zh":"磁场强度：","search_zh":"工作环境 － 医疗技术设备产生的电磁场：－ 外科电刀 － 理疗透热治疗仪 磁场强度： 直接测量法 检测实验室 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r.","technique_zh":"直接测量法","test_object_zh":"工作环境 － 医疗技术设备产生的电磁场：－ 外科电刀 － 理疗透热治疗仪"},{"_id":"6a82deaf884ede9a1b2c3538","lab_id":"69ad52a3de79e566650fb6d2","country":"PL","accr_number":"AB 1333","accr_body":"PCA","test_object":"Środowisko pracy − pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości od 800 MHz – 90 GHz (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego:\nw zakresie częstotliwości od 800 MHz – 90 GHz (z obliczeń)","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r.","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","P-14 wydanie 16 z dnia 24.04.2026 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne Natężenie pola magnetycznego:\nw zakresie częstotliwości od 800 MHz – 90 GHz (z obliczeń) PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r. Srodowisko pracy − pole elektromagnetyczne pochodzace od urzadzen stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne Natezenie pola magnetycznego:\nw zakresie czestotliwosci od 800 MHz – 90 GHz (z obliczen) PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r.","categories":["environment"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Magnetic field strength:","search_en":"Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units Magnetic field strength: Testing Laboratory PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r.","test_object_en":"Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units","lab_section_zh":"检测实验室","methodology_zh":"磁场强度：","search_zh":"工作环境 － 医疗技术设备产生的电磁场：－ 外科电刀 － 理疗透热治疗仪 磁场强度： 检测实验室 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | P-14 wydanie 16 z dnia 24.04.2026 r.","test_object_zh":"工作环境 － 医疗技术设备产生的电磁场：－ 外科电刀 － 理疗透热治疗仪"},{"_id":"6a82deaf884ede9a1b2c3539","lab_id":"69ad52a3de79e566650fb6d2","country":"PL","accr_number":"AB 1333","accr_body":"PCA","test_object":"Środowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe)","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"w zakresie częstotliwości od 200 kHz do 3 GHz","range":"Zakres: (0,8 – 1000) V/m"},{"name":"w zakresie częstotliwości od 3 GHz do 90 GHz","range":"Zakres: (0,8 – 300) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 200 kHz do 3 GHz Zakres: (0,8 – 1000) V/m\nw zakresie częstotliwości od 3 GHz do 90 GHz Zakres: (0,8 – 300) V/m\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17 lutego 2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17 lutego 2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Środowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 200 kHz do 3 GHz Zakres: (0,8 – 1000) V/m\nw zakresie częstotliwości od 3 GHz do 90 GHz Zakres: (0,8 – 300) V/m\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17 lutego 2020 r. (Dz.U. 2022 poz. 2630) Srodowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 200 kHz do 3 GHz Zakres: (0,8 – 1000) V/m\nw zakresie czestotliwosci od 3 GHz do 90 GHz Zakres: (0,8 – 300) V/m\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17 lutego 2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Electric field strength:","search_en":"Environment - electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Electric field strength: Direct measurement method Testing Laboratory Załącznik do Rozporządzenia Ministra Klimatu z dnia 17 lutego 2020 r. (Dz.U. 2022 poz. 2630)","technique_en":"Direct measurement method","test_object_en":"Environment - electromagnetic field in the vicinity of radiocommunication installations (broadband measurements)","lab_section_zh":"检测实验室","methodology_zh":"电场强度：","search_zh":"环境 － 无线电通信设施周围的电磁场（宽带测量） 电场强度： 直接测量法 检测实验室 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17 lutego 2020 r. (Dz.U. 2022 poz. 2630)","technique_zh":"直接测量法","test_object_zh":"环境 － 无线电通信设施周围的电磁场（宽带测量）"},{"_id":"6a82deaf884ede9a1b2c353a","lab_id":"69ad52a3de79e566650fb6d2","country":"PL","accr_number":"AB 1333","accr_body":"PCA","test_object":"Środowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe)","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości od 200 kHz do 40 MHz","range":"Zakres: (0,02 – 16) A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola magnetycznego:\nw zakresie częstotliwości od 200 kHz do 40 MHz Zakres: (0,02 – 16) A/m\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17 lutego 2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17 lutego 2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Środowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natężenie pola magnetycznego:\nw zakresie częstotliwości od 200 kHz do 40 MHz Zakres: (0,02 – 16) A/m\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17 lutego 2020 r. (Dz.U. 2022 poz. 2630) Srodowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natezenie pola magnetycznego:\nw zakresie czestotliwosci od 200 kHz do 40 MHz Zakres: (0,02 – 16) A/m\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17 lutego 2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Magnetic field strength:","search_en":"Environment - electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Magnetic field strength: Direct measurement method Testing Laboratory Załącznik do Rozporządzenia Ministra Klimatu z dnia 17 lutego 2020 r. (Dz.U. 2022 poz. 2630)","technique_en":"Direct measurement method","test_object_en":"Environment - electromagnetic field in the vicinity of radiocommunication installations (broadband measurements)","lab_section_zh":"检测实验室","methodology_zh":"磁场强度：","search_zh":"环境 － 无线电通信设施周围的电磁场（宽带测量） 磁场强度： 直接测量法 检测实验室 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17 lutego 2020 r. (Dz.U. 2022 poz. 2630)","technique_zh":"直接测量法","test_object_zh":"环境 － 无线电通信设施周围的电磁场（宽带测量）"},{"_id":"6a82deaf884ede9a1b2c353b","lab_id":"69ad52a3de79e566650fb6d2","country":"PL","accr_number":"AB 1333","accr_body":"PCA","test_object":"Środowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe)","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości od 10 MHz do 90 GHz (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego:\nw zakresie częstotliwości od 10 MHz do 90 GHz (z obliczeń)","reference":"Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Środowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natężenie pola magnetycznego:\nw zakresie częstotliwości od 10 MHz do 90 GHz (z obliczeń) Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko - pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natezenie pola magnetycznego:\nw zakresie czestotliwosci od 10 MHz do 90 GHz (z obliczen) Punkt 3 zalacznika do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Magnetic field strength:","search_en":"Environment - electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Magnetic field strength: Testing Laboratory Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","test_object_en":"Environment - electromagnetic field in the vicinity of radiocommunication installations (broadband measurements)","lab_section_zh":"检测实验室","methodology_zh":"磁场强度：","search_zh":"环境 － 无线电通信设施周围的电磁场（宽带测量） 磁场强度： 检测实验室 Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","test_object_zh":"环境 － 无线电通信设施周围的电磁场（宽带测量）"},{"_id":"6a82deaf884ede9a1b2c353c","lab_id":"69ad52a3de79e566650fb6d2","country":"PL","accr_number":"AB 1333","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne pochodzące od urządzeń nadawczych systemów radiokomunikacyjnych (stacje bazowe systemów telefonii komórkowej; nadawcze systemy tele- i radiokomunikacyjne - radio, telewizja, itp.)","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"w zakresie częstotliwości od 100 kHz do 3 GHz","range":"Zakres: (0,8 – 1000) V/m"},{"name":"w zakresie częstotliwości od 3 GHz do 90 GHz","range":"Zakres: (0,8 – 300) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 100 kHz do 3 GHz Zakres: (0,8 – 1000) V/m\nw zakresie częstotliwości od 3 GHz do 90 GHz Zakres: (0,8 – 300) V/m\nMetoda pomiarowa bezpośrednia","reference":"Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331).","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne pochodzące od urządzeń nadawczych systemów radiokomunikacyjnych (stacje bazowe systemów telefonii komórkowej; nadawcze systemy tele- i radiokomunikacyjne - radio, telewizja, itp.) Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 100 kHz do 3 GHz Zakres: (0,8 – 1000) V/m\nw zakresie częstotliwości od 3 GHz do 90 GHz Zakres: (0,8 – 300) V/m\nMetoda pomiarowa bezpośrednia Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131 Srodowisko pracy - pole elektromagnetyczne pochodzace od urzadzen nadawczych systemow radiokomunikacyjnych (stacje bazowe systemow telefonii komorkowej; nadawcze systemy tele- i radiokomunikacyjne - radio, telewizja, itp.) Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 100 kHz do 3 GHz Zakres: (0,8 – 1000) V/m\nw zakresie czestotliwosci od 3 GHz do 90 GHz Zakres: (0,8 – 300) V/m\nMetoda pomiarowa bezposrednia Podstawy i Metody Oceny Srodowiska Pracy 2017, nr 2 (92), s. 89 – 131","categories":["environment"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Electric field strength:","search_en":"Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (mobile telephony base stations; broadcasting and radiocommunication systems - radio, television, etc.) Electric field strength: Direct measurement method Testing Laboratory Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131","technique_en":"Direct measurement method","test_object_en":"Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (mobile telephony base stations; broadcasting and radiocommunication systems - radio, television, etc.)","lab_section_zh":"检测实验室","methodology_zh":"电场强度：","search_zh":"工作环境 － 无线电通信系统发射设备产生的电磁场（移动电话系统基站；广播与无线电通信发射系统） 电场强度： 直接测量法 检测实验室 Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131","technique_zh":"直接测量法","test_object_zh":"工作环境 － 无线电通信系统发射设备产生的电磁场（移动电话系统基站；广播与无线电通信发射系统）"},{"_id":"6a82deaf884ede9a1b2c353d","lab_id":"69ad52a3de79e566650fb6d2","country":"PL","accr_number":"AB 1333","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne pochodzące od urządzeń nadawczych systemów radiokomunikacyjnych (stacje bazowe systemów telefonii komórkowej; nadawcze systemy tele- i radiokomunikacyjne - radio, telewizja, itp.)","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości od 100 kHz do 40 MHz","range":"Zakres: (0,01 – 16,0) A/m"},{"name":"w zakresie częstotliwości od 20 MHz do 800 MHz","range":"Zakres: (0,02 – 1,2) A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 100 kHz do 40 MHz Zakres: (0,01 – 16,0) A/m\nw zakresie częstotliwości od 20 MHz do 800 MHz Zakres: (0,02 – 1,2) A/m\nMetoda pomiarowa bezpośrednia","reference":"Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331).","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne pochodzące od urządzeń nadawczych systemów radiokomunikacyjnych (stacje bazowe systemów telefonii komórkowej; nadawcze systemy tele- i radiokomunikacyjne - radio, telewizja, itp.) Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 100 kHz do 40 MHz Zakres: (0,01 – 16,0) A/m\nw zakresie częstotliwości od 20 MHz do 800 MHz Zakres: (0,02 – 1,2) A/m\nMetoda pomiarowa bezpośrednia Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131 Srodowisko pracy - pole elektromagnetyczne pochodzace od urzadzen nadawczych systemow radiokomunikacyjnych (stacje bazowe systemow telefonii komorkowej; nadawcze systemy tele- i radiokomunikacyjne - radio, telewizja, itp.) Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 100 kHz do 40 MHz Zakres: (0,01 – 16,0) A/m\nw zakresie czestotliwosci od 20 MHz do 800 MHz Zakres: (0,02 – 1,2) A/m\nMetoda pomiarowa bezposrednia Podstawy i Metody Oceny Srodowiska Pracy 2017, nr 2 (92), s. 89 – 131","categories":["environment"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Magnetic field strength:","search_en":"Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (mobile telephony base stations; broadcasting and radiocommunication systems - radio, television, etc.) Magnetic field strength: Direct measurement method Testing Laboratory Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131","technique_en":"Direct measurement method","test_object_en":"Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (mobile telephony base stations; broadcasting and radiocommunication systems - radio, television, etc.)","lab_section_zh":"检测实验室","methodology_zh":"磁场强度：","search_zh":"工作环境 － 无线电通信系统发射设备产生的电磁场（移动电话系统基站；广播与无线电通信发射系统） 磁场强度： 直接测量法 检测实验室 Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131","technique_zh":"直接测量法","test_object_zh":"工作环境 － 无线电通信系统发射设备产生的电磁场（移动电话系统基站；广播与无线电通信发射系统）"},{"_id":"6a82deaf884ede9a1b2c353e","lab_id":"69ad52a3de79e566650fb6d2","country":"PL","accr_number":"AB 1333","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne pochodzące od urządzeń nadawczych systemów radiokomunikacyjnych (stacje bazowe systemów telefonii komórkowej; nadawcze systemy tele- i radiokomunikacyjne - radio, telewizja, itp.)","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości od 800 MHz do 90 GHz (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego:\nw zakresie częstotliwości od 800 MHz do 90 GHz (z obliczeń)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331).","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne pochodzące od urządzeń nadawczych systemów radiokomunikacyjnych (stacje bazowe systemów telefonii komórkowej; nadawcze systemy tele- i radiokomunikacyjne - radio, telewizja, itp.) Natężenie pola magnetycznego:\nw zakresie częstotliwości od 800 MHz do 90 GHz (z obliczeń) Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131 Srodowisko pracy - pole elektromagnetyczne pochodzace od urzadzen nadawczych systemow radiokomunikacyjnych (stacje bazowe systemow telefonii komorkowej; nadawcze systemy tele- i radiokomunikacyjne - radio, telewizja, itp.) Natezenie pola magnetycznego:\nw zakresie czestotliwosci od 800 MHz do 90 GHz (z obliczen) Podstawy i Metody Oceny Srodowiska Pracy 2017, nr 2 (92), s. 89 – 131","categories":["environment"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Magnetic field strength:","search_en":"Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (mobile telephony base stations; broadcasting and radiocommunication systems - radio, television, etc.) Magnetic field strength: Testing Laboratory Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131","test_object_en":"Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (mobile telephony base stations; broadcasting and radiocommunication systems - radio, television, etc.)","lab_section_zh":"检测实验室","methodology_zh":"磁场强度：","search_zh":"工作环境 － 无线电通信系统发射设备产生的电磁场（移动电话系统基站；广播与无线电通信发射系统） 磁场强度： 检测实验室 Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 – 131","test_object_zh":"工作环境 － 无线电通信系统发射设备产生的电磁场（移动电话系统基站；广播与无线电通信发射系统）"},{"_id":"6a82deaf884ede9a1b2c353f","lab_id":"69ad52a3de79e566650fb6d2","country":"PL","accr_number":"AB 1333","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne pochodzące od urządzeń do magnetoterapii","methodology":"Indukcja magnetyczna:","parameters":[{"name":"w zakresie częstotliwości od 20 Hz do 50 Hz","range":"Zakres: 1µT – 10,0 mT"}],"technique":"Metoda pomiarowa bezpośrednia (uproszczona)","techniques":["Metoda pomiarowa bezpośrednia (uproszczona)"],"computed":[],"activity":"Indukcja magnetyczna:\nw zakresie częstotliwości od 20 Hz do 50 Hz Zakres: 1µT – 10,0 mT\nMetoda pomiarowa bezpośrednia (uproszczona)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331).","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne pochodzące od urządzeń do magnetoterapii Indukcja magnetyczna:\nw zakresie częstotliwości od 20 Hz do 50 Hz Zakres: 1µT – 10,0 mT\nMetoda pomiarowa bezpośrednia (uproszczona) Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180 Srodowisko pracy - pole elektromagnetyczne pochodzace od urzadzen do magnetoterapii Indukcja magnetyczna:\nw zakresie czestotliwosci od 20 Hz do 50 Hz Zakres: 1µT – 10,0 mT\nMetoda pomiarowa bezposrednia (uproszczona) Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4 (90), s. 151 - 180","categories":["environment"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Magnetic flux density:","search_en":"Workplace environment - electromagnetic field from magnetotherapy equipment Magnetic flux density: Direct measurement method (simplified) Testing Laboratory Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180","technique_en":"Direct measurement method (simplified)","test_object_en":"Workplace environment - electromagnetic field from magnetotherapy equipment","lab_section_zh":"检测实验室","search_zh":"磁感应强度： 直接测量法（简化） 检测实验室 Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180","methodology_zh":"磁感应强度：","technique_zh":"直接测量法（简化）"}],"has_pdf":true}