🇵🇱 Przedsiębiorstwo Gospodarki Komunalnej Sp. z o.o. PL
Water & wastewaterMicrobiology
Przedsiębiorstwo Gospodarki Komunalnej Sp. z o.o. is a laboratory accredited by PCA under number AB 1310 (Lubartów, Poland). Its accreditation scope covers 55 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water, Water intended for human consumption, Wastewater. Most frequently used techniques: Spectrophotometric method, Titrimetric method, Membrane filtration method.
At a glance
- Accreditation number: PCA AB 1310
- Methods in scope: 55
- Types of test objects: 3
- Techniques used: 10
- City: Lubartów, Poland
- Accreditation number
- AB 1310
- Accreditation body
- PCA
- Address
- ul. Parkowa 6, 21-100 Lubartów, LABORATORIUM, ul. Nowodworska 11, 21-100 Lubartów
- City
- Lubartów, Poland
What this laboratory tests (3)
- Water — 22 methods
- Water intended for human consumption — 19 methods
- Wastewater — 14 methods
Analytical techniques used (10)
- Spectrophotometric method — 14 methods
- Titrimetric method — 10 methods
- Membrane filtration method — 6 methods
- Gravimetric method — 4 methods
- Plate method (pour plate) — 4 methods
- Potentiometric method — 3 methods
- Conductometric method — 2 methods
- Nephelometric method — 2 methods
- Manual method; Automatic method — 1 method
- Optical method — 1 method
Laboratory locations
- Przedsiębiorstwo Gospodarki Komunalnej Sp. z o.o. (Municipal Services Company) (main site) — ul. Parkowa 6, 21-100 Lubartów
- Laboratory — ul. Nowodworska 11, 21-100 Lubartów
Certificate information
- Issue date
- 05.11.2026
- Issue no.
- 16
Accreditation scope — test methods (55)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Wastewater | Sampling for chemical and physical testing | Manual method; Automatic method | PN-ISO 5667-10:2021-11 | |
| 2 | Wastewater | pH Range (2,0 – 10,0) |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 3 | Wastewater | Total suspended solids (TSS) Range (5,0 – 3 000) mg/l |
Gravimetric method | PN-EN 872:2007 +Ap1:2007 | |
| 4 | Wastewater | Chemical oxygen demand - COD Range (30 – 10 000) mg/l O2 |
Titrimetric method | PN-ISO 6060:2006 | |
| 5 | Wastewater | Biochemical oxygen demand - BOD5 Range (3 – 2 500) mg/l O2 |
Optical method | PN-EN ISO 5815-1:2019-12 | |
| 6 | Wastewater | Ammonium nitrogen concentration Range (5,0 – 300 ) mg/l |
Titrimetric method | PN-ISO 5664:2002 | |
| 7 | Wastewater | Ammonium nitrogen concentration Range (0,05 – 40,0) mg/l |
Spectrophotometric method | PN-ISO 7150-1:2002 | |
| 8 | Wastewater | Nitrate nitrogen concentration Range (0,20 – 30,0) mg/l |
Spectrophotometric method | PN-82/C-04576.08 | |
| 9 | Wastewater | Nitrite nitrogen concentration Range (0,03 – 2,0) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 10 | Wastewater | Chloride concentration Range (5,00 – 400) mg/l |
Titrimetric method | PN-ISO 9297:1994 | |
| 11 | Wastewater | Total phosphorus concentration Range (0,10 – 60,0) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006 cl. 7 +Ap1:2010 +Ap2:2010 | |
| 12 | Wastewater | Total Kjeldahl nitrogen concentration Range (2,00 – 500) mg/l |
Titrimetric method | PN-EN 25663:2001 | |
| 13 | Wastewater | Total nitrogen concentration (calculated) | PN-73/C-04576.14 | ||
| 14 | Wastewater | Sulphate (VI) concentration Range (20 – 300) mg/l |
Gravimetric method | PN-ISO 9280:2002 | |
| 15 | Water | Sampling for chemical and physical testing | PN-ISO 5667-5:2017-10 +Ap1:2019-07 | ||
| 16 | Water | pH Range (2,0 – 10,0) |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 17 | Water | Ammonium nitrogen concentration Range (0,05 – 5,0) mg/l |
Spectrophotometric method | PN-ISO 7150-1:2002 | |
| 18 | Water | Ammonium ion concentration (calculated) | PN-ISO 7150-1:2002 | ||
| 19 | Water | Nitrate nitrogen concentration Range (0,20 – 12,0) mg/l |
Spectrophotometric method | PN-82/C-04576.08 | |
| 20 | Water | Nitrate concentration (calculated) | PN-82/C-04576.08 | ||
| 21 | Water | Nitrite nitrogen concentration Range (0,03 – 0,25) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 22 | Water | Nitrite concentration (calculated) | PN-EN 26777:1999 | ||
| 23 | Water | Chloride concentration Range (5,00 – 400) mg/l |
Titrimetric method | PN-ISO 9297:1994 | |
| 24 | Water | Turbidity Range (0,2 – 10,0) NTU |
Nephelometric method | PN-EN ISO 7027-1:2016-09 | |
| 25 | Water | Electrical conductivity Range (147 – 2 500) µS/cm |
Conductometric method | PN-EN 27888:1999 | |
| 26 | Water | Iron concentration Range (50 – 5 000) µg/l |
Spectrophotometric method | PN-ISO 6332:2001 cl. 7.1 +Ap1:2016-06 | |
| 27 | Water | Total calcium and magnesium content (Total hardness) Range (15 – 500) mg/l CaCO3 |
Titrimetric method | PN-ISO 6059:1999 | |
| 28 | Water | Oxidability (Permanganate index) Range (0,60 – 6,0) mg/l O2 |
Titrimetric method | PN-EN ISO 8467:2001 | |
| 29 | Water | Colour Range (5 – 50) mg/l Pt |
Spectrophotometric method | PN-EN ISO 7887:2012 cl. 6 +Ap1:2015-06 | |
| 30 | Water | Sulphate (VI) concentration Range (20 – 300) mg/l |
Gravimetric method | PN-ISO 9280:2002 | |
| 31 | Water | Sampling for microbiological testing | PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.3; 4.4.4; 4.4.5; 4.4.6 | ||
| 32 | Water | Ogólna liczba mikroorganizmów inkubowanych w temperaturze 22°C | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 33 | Water | Ogólna liczba mikroorganizmów inkubowanych w temperaturze 36 ± 2 °C | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 34 | Water | Presence and number of enterococci | Membrane filtration method | PN-EN ISO 7899-2:2004 | |
| 35 | Water | Presence and count of coliform bacteria | Membrane filtration method | PN-EN ISO 9308-1:2014+A1:2017 | |
| 36 | Water | Obecność i liczba Escherichia coli (E. coli) | Membrane filtration method | PN-EN ISO 9308-1:2014+A1:2017 | |
| 37 | Water intended for human consumption | Sampling for chemical and physical testing Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal. |
PN-ISO 5667-5:2017-10+Ap1:2019-07 | ||
| 38 | Water intended for human consumption | pH Range (2,0 – 10,0) Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal. |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 39 | Water intended for human consumption | Ammonium ion concentration Range (0,06 – 6,50) mg/l Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal. |
Spectrophotometric method | PN-ISO 7150-1:2002 | |
| 40 | Water intended for human consumption | Nitrate concentration Range (0,9 – 53) mg/l Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal. |
Spectrophotometric method | PN-82/C-04576.08 | |
| 41 | Water intended for human consumption | Nitrite concentration Range (0,10 – 0,80) mg/l Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal. |
Spectrophotometric method | PN-EN 26777:1999 | |
| 42 | Water intended for human consumption | Chloride concentration Range (5,00 – 400) mg/l Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal. |
Titrimetric method | PN-ISO 9297:1994 | |
| 43 | Water intended for human consumption | Turbidity Range (0,2 – 10,0) NTU Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal. |
Nephelometric method | PN-EN ISO 7027-1:2016-09 | |
| 44 | Water intended for human consumption | Electrical conductivity Range (147 – 2 500) µS/cm Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal. |
Conductometric method | PN-EN 27888:1999 | |
| 45 | Water intended for human consumption | Iron concentration Range (50 – 5 000) µg/l Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal. |
Spectrophotometric method | PN-ISO 6332:2001 cl. 7.1 +Ap1:2016-06 | |
| 46 | Water intended for human consumption | Total content of calcium and magnesium (total hardness) Range (15 – 500) mg/l CaCO3 Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal. |
Titrimetric method | PN-ISO 6059:1999 | |
| 47 | Water intended for human consumption | Permanganate index (Oxidisability) Range (0,60 – 6,0) mg/l O2 Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal. |
Titrimetric method | PN-EN ISO 8467:2001 | |
| 48 | Water intended for human consumption | Colour Range (5 – 50) mg/l Pt Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal. |
Spectrophotometric method | PN-EN ISO 7887:2012 cl. 6 +Ap1:2015-06 | |
| 49 | Water intended for human consumption | Sulphate (VI) concentration Range (20 – 300) mg/l Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal. |
Gravimetric method | PN-ISO 9280:2002 | |
| 50 | Water intended for human consumption | Sampling for microbiological testing Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal. |
PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.3; 4.4.4; 4.4.5; 4.4.6 | ||
| 51 | Water intended for human consumption | Liczba kolonii na agarze odżywczym w temp. 22° C Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal. |
Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 52 | Water intended for human consumption | Liczba kolonii na agarze odżywczym w temp 36 ± 2 °C Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal. |
Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 53 | Water intended for human consumption | Intestinal enterococci count Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal. |
Membrane filtration method | PN-EN ISO 7899-2:2004 | |
| 54 | Water intended for human consumption | Coliform bacteria count Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal. |
Membrane filtration method | PN-EN ISO 9308-1:2014+A1:2017 | |
| 55 | Water intended for human consumption | Liczba Escherichia coli (E. coli) Regulated area: Sampling and testing of water intended for human consumption performed for the purposes of the legally regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of legal acts to the Act of 7 June 2001 on collective water supply and collective wastewater disposal. |
Membrane filtration method | PN-EN ISO 9308-1:2014+A1:2017 | |
Reference standards (26)
PN-73/C-04576.14
PN-82/C-04576.08
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007 +Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.3; 4.4.4; 4.4.5; 4.4.6
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006 cl. 7 +Ap1:2010 +Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 cl. 6 +Ap1:2015-06
PN-EN ISO 7899-2:2004
PN-EN ISO 8467:2001
PN-EN ISO 9308-1:2014+A1:2017
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10 +Ap1:2019-07
PN-ISO 5667-5:2017-10+Ap1:2019-07
PN-ISO 6059:1999
PN-ISO 6060:2006
PN-ISO 6332:2001 cl. 7.1 +Ap1:2016-06
PN-ISO 7150-1:2002
PN-ISO 9280:2002
PN-ISO 9297:1994