🇵🇱 Przedsiębiorstwo Gospodarki Komunalnej Sp. z o.o. PL
Water & wastewater
Przedsiębiorstwo Gospodarki Komunalnej Sp. z o.o. is a laboratory accredited by PCA under number AB 1310 (Lubartów, Poland). Its accreditation scope covers 35 test methods in the following areas: Water & wastewater. Test objects include: Water, Wastewater.
At a glance
- Accreditation number: PCA AB 1310
- Methods in scope: 35
- Types of test objects: 2
- City: Lubartów, Poland
- Accreditation number
- AB 1310
- Accreditation body
- PCA
- Address
- ul. Parkowa 6, 21-100 Lubartów, LABORATORIUM, ul. Nowodworska 11, 21-100 Lubartów
- City
- Lubartów, Poland
What this laboratory tests (2)
- Water — 19 methods
- Wastewater — 16 methods
Accreditation scope — test methods (35)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Wastewater | Sampling for chemical and physical testing Manual method Automatic method | PN-ISO 5667-10:2021-11 | ||
| 2 | Wastewater | pH Range: (2,0 – 10,0) Potentiometric method | PN-EN ISO 10523:2012 | ||
| 3 | Wastewater | Total suspended solids Range: (5,0 – 3 000) mg/l Gravimetric method | PN-EN 872:2007 +Ap1:2007 | ||
| 4 | Wastewater | Chemical oxygen demand - COD Range: (30,0 – 11 000) mg/l O 2 Titrimetric method | PN-ISO 6060:2006 | ||
| 5 | Wastewater | Biochemical oxygen demand - BOD 5 Range: (3 – 2 500) mg/l O 2 Optical method | PN-EN ISO 5815-1:2019-12 | ||
| 6 | Wastewater | Biochemical oxygen demand - BOD 5 Range: (0,5 – 6,0) mg/l O 2 Optical method | PN-EN 1899-2:2002 z wył. p. 7.2.1 | Instrukcja Badawcza IB-01.00.00 wyd. 1 z dnia 19.09.2019 r. | ||
| 7 | Wastewater | Dissolved oxygen concentration Range: (0,5 – 10,0) mg/l O 2 Optical method | ISO 17289:2014 | ||
| 8 | Wastewater | Ammonium nitrogen concentration Range: (5,0 – 300 ) mg/l Titrimetric method | PN-ISO 5664:2002 | ||
| 9 | Wastewater | Ammonium nitrogen concentration Range: (0,05 – 40,0) mg/l Spectrophotometric method | PN-ISO 7150-1:2002 | ||
| 10 | Wastewater | Nitrate nitrogen concentration Range: (0,10 – 30,0) mg/l Spectrophotometric method | PN-82/C-04576.08 | ||
| 11 | Wastewater | Nitrite nitrogen concentration Range: (0,03 – 2,0) mg/l Spectrophotometric method | PN-EN 26777:1999 | ||
| 12 | Wastewater | Chloride concentration Range: (5 – 1 000) mg/l Titrimetric method | PN-ISO 9297:1994 | ||
| 13 | Wastewater | Total phosphorus concentration Range: (0,10 – 60,0) mg/l Spectrophotometric method | PN-EN ISO 6878:2006 p. 7 +Ap1:2010 +Ap2:2010 | ||
| 14 | Wastewater | Total Kjeldahl nitrogen concentration Range: (2,00 – 500) mg/l Titrimetric method | PN-EN 25663:2001 | ||
| 15 | Wastewater | Total nitrogen concentration (calculated) | PN-73/C-04576.14 | ||
| 16 | Wastewater | Sulfate (VI) concentration Range: (20 – 300) mg/l Gravimetric method | PN-ISO 9280:2002 | ||
| 17 | Water | pH Range: (2,0 – 10,0) Potentiometric method | PN-EN ISO 10523:2012 | ||
| 18 | Water | Ammonium nitrogen concentration Range: (0,05 – 5,0) mg/l Spectrophotometric method | PN-ISO 7150-1:2002 | ||
| 19 | Water | Ammonium ion concentration (calculated) | |||
| 20 | Water | Nitrate nitrogen concentration Range: (0,05 – 10,0) mg/l Spectrophotometric method | PN-82/C-04576.08 | ||
| 21 | Water | Nitrate concentration (calculated) | |||
| 22 | Water | Nitrite nitrogen concentration Range: (0,003 – 2,0) mg/l Spectrophotometric method | PN-EN 26777:1999 | ||
| 23 | Water | Nitrite concentration (calculated) | |||
| 24 | Water | Chloride concentration Range: (5 – 200) mg/l Titrimetric method | PN-ISO 9297:1994 | ||
| 25 | Water | Turbidity Range: (0,2 – 10,0) NTU Nephelometric method | PN-EN ISO 7027-1:2016-09 | ||
| 26 | Water | Electrical conductivity Range: (150 – 1 500) µS/cm Conductometric method | PN-EN 27888:1999 | ||
| 27 | Water | Manganese concentration Range: (20,0 – 15 000) µg/l Spectrophotometric method | PN-C-04590.02:1992 | ||
| 28 | Water | Total iron concentration Range: (30 – 10 000) µg/l Spectrophotometric method | PN-ISO 6332:2001 p.7.1 +Ap1:2016-06 | ||
| 29 | Water | Total calcium and magnesium content (Total hardness) Range: (5 – 500)mg/l CaCO 3 Titrimetric method | PN-ISO 6059:1999 | ||
| 30 | Water | Permanganate index Range: (0,5 – 10,0) mg/l O 2 Titrimetric method | PN-EN ISO 8467:2001 | ||
| 31 | Water | Colour Range: (5,0 – 50,0) mg/l Pt Spectrophotometric method | PN-EN ISO 7887:2012 p. 6 +Ap1:2015-06 | ||
| 32 | Water | Sulfate (VI) concentration Range: (20 – 300) mg/l Gravimetric method | PN-ISO 9280:2002 | ||
| 33 | Water | Total count of microorganisms incubated at 22°C and 36°C Plate method (pour plate) | PN-EN ISO 6222:2004 | ||
| 34 | Water | Presence and count of enterococci (faecal streptococci) Membrane filtration method | PN-EN ISO 7899-2:2004 | ||
| 35 | Water | Presence and number of Escherichia coli and coliform bacteria Membrane filtration method | PN-EN ISO 9308-1:2014+A1:2017 | ||
Reference standards (27)
ISO 17289:2014
Instrukcja Badawcza IB-01.00.00 wyd. 1 z dnia 19.09.2019 r.
PN-73/C-04576.14
PN-82/C-04576.08
PN-C-04590.02:1992
PN-EN 1899-2:2002 z wył. p. 7.2.1
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007 +Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006 p. 7 +Ap1:2010 +Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 p. 6 +Ap1:2015-06
PN-EN ISO 7899-2:2004
PN-EN ISO 8467:2001
PN-EN ISO 9308-1:2014+A1:2017
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 6059:1999
PN-ISO 6060:2006
PN-ISO 6332:2001 p.7.1 +Ap1:2016-06
PN-ISO 7150-1:2002
PN-ISO 9280:2002
PN-ISO 9297:1994