🇵🇱 Przedsiębiorstwo Gospodarki Komunalnej Sp. z o.o. PL

PCA AB 1310 • Lubartów, Poland • 35 methods

Water & wastewater

Przedsiębiorstwo Gospodarki Komunalnej Sp. z o.o. is a laboratory accredited by PCA under number AB 1310 (Lubartów, Poland). Its accreditation scope covers 35 test methods in the following areas: Water & wastewater. Test objects include: Water, Wastewater.

At a glance

  • Accreditation number: PCA AB 1310
  • Methods in scope: 35
  • Types of test objects: 2
  • City: Lubartów, Poland
Accreditation number
AB 1310
Accreditation body
PCA
Address
ul. Parkowa 6, 21-100 Lubartów, LABORATORIUM, ul. Nowodworska 11, 21-100 Lubartów
City
Lubartów, Poland

What this laboratory tests (2)

Accreditation scope — test methods (35)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Wastewater Sampling for chemical and physical testing Manual method Automatic method PN-ISO 5667-10:2021-11
2 Wastewater pH Range: (2,0 – 10,0) Potentiometric method PN-EN ISO 10523:2012
3 Wastewater Total suspended solids Range: (5,0 – 3 000) mg/l Gravimetric method PN-EN 872:2007 +Ap1:2007
4 Wastewater Chemical oxygen demand - COD Range: (30,0 – 11 000) mg/l O 2 Titrimetric method PN-ISO 6060:2006
5 Wastewater Biochemical oxygen demand - BOD 5 Range: (3 – 2 500) mg/l O 2 Optical method PN-EN ISO 5815-1:2019-12
6 Wastewater Biochemical oxygen demand - BOD 5 Range: (0,5 – 6,0) mg/l O 2 Optical method PN-EN 1899-2:2002 z wył. p. 7.2.1 | Instrukcja Badawcza IB-01.00.00 wyd. 1 z dnia 19.09.2019 r.
7 Wastewater Dissolved oxygen concentration Range: (0,5 – 10,0) mg/l O 2 Optical method ISO 17289:2014
8 Wastewater Ammonium nitrogen concentration Range: (5,0 – 300 ) mg/l Titrimetric method PN-ISO 5664:2002
9 Wastewater Ammonium nitrogen concentration Range: (0,05 – 40,0) mg/l Spectrophotometric method PN-ISO 7150-1:2002
10 Wastewater Nitrate nitrogen concentration Range: (0,10 – 30,0) mg/l Spectrophotometric method PN-82/C-04576.08
11 Wastewater Nitrite nitrogen concentration Range: (0,03 – 2,0) mg/l Spectrophotometric method PN-EN 26777:1999
12 Wastewater Chloride concentration Range: (5 – 1 000) mg/l Titrimetric method PN-ISO 9297:1994
13 Wastewater Total phosphorus concentration Range: (0,10 – 60,0) mg/l Spectrophotometric method PN-EN ISO 6878:2006 p. 7 +Ap1:2010 +Ap2:2010
14 Wastewater Total Kjeldahl nitrogen concentration Range: (2,00 – 500) mg/l Titrimetric method PN-EN 25663:2001
15 Wastewater Total nitrogen concentration (calculated) PN-73/C-04576.14
16 Wastewater Sulfate (VI) concentration Range: (20 – 300) mg/l Gravimetric method PN-ISO 9280:2002
17 Water pH Range: (2,0 – 10,0) Potentiometric method PN-EN ISO 10523:2012
18 Water Ammonium nitrogen concentration Range: (0,05 – 5,0) mg/l Spectrophotometric method PN-ISO 7150-1:2002
19 Water Ammonium ion concentration (calculated)
20 Water Nitrate nitrogen concentration Range: (0,05 – 10,0) mg/l Spectrophotometric method PN-82/C-04576.08
21 Water Nitrate concentration (calculated)
22 Water Nitrite nitrogen concentration Range: (0,003 – 2,0) mg/l Spectrophotometric method PN-EN 26777:1999
23 Water Nitrite concentration (calculated)
24 Water Chloride concentration Range: (5 – 200) mg/l Titrimetric method PN-ISO 9297:1994
25 Water Turbidity Range: (0,2 – 10,0) NTU Nephelometric method PN-EN ISO 7027-1:2016-09
26 Water Electrical conductivity Range: (150 – 1 500) µS/cm Conductometric method PN-EN 27888:1999
27 Water Manganese concentration Range: (20,0 – 15 000) µg/l Spectrophotometric method PN-C-04590.02:1992
28 Water Total iron concentration Range: (30 – 10 000) µg/l Spectrophotometric method PN-ISO 6332:2001 p.7.1 +Ap1:2016-06
29 Water Total calcium and magnesium content (Total hardness) Range: (5 – 500)mg/l CaCO 3 Titrimetric method PN-ISO 6059:1999
30 Water Permanganate index Range: (0,5 – 10,0) mg/l O 2 Titrimetric method PN-EN ISO 8467:2001
31 Water Colour Range: (5,0 – 50,0) mg/l Pt Spectrophotometric method PN-EN ISO 7887:2012 p. 6 +Ap1:2015-06
32 Water Sulfate (VI) concentration Range: (20 – 300) mg/l Gravimetric method PN-ISO 9280:2002
33 Water Total count of microorganisms incubated at 22°C and 36°C Plate method (pour plate) PN-EN ISO 6222:2004
34 Water Presence and count of enterococci (faecal streptococci) Membrane filtration method PN-EN ISO 7899-2:2004
35 Water Presence and number of Escherichia coli and coliform bacteria Membrane filtration method PN-EN ISO 9308-1:2014+A1:2017

Reference standards (27)

ISO 17289:2014
Instrukcja Badawcza IB-01.00.00 wyd. 1 z dnia 19.09.2019 r.
PN-73/C-04576.14
PN-82/C-04576.08
PN-C-04590.02:1992
PN-EN 1899-2:2002 z wył. p. 7.2.1
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007 +Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006 p. 7 +Ap1:2010 +Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 p. 6 +Ap1:2015-06
PN-EN ISO 7899-2:2004
PN-EN ISO 8467:2001
PN-EN ISO 9308-1:2014+A1:2017
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 6059:1999
PN-ISO 6060:2006
PN-ISO 6332:2001 p.7.1 +Ap1:2016-06
PN-ISO 7150-1:2002
PN-ISO 9280:2002
PN-ISO 9297:1994