{"lab":{"_id":"69ad52a3de79e566650fb6ba","accr_number":"AB 1310","country":"PL","accr_body":"PCA","address":"ul. Parkowa 6, 21-100 Lubartów, LABORATORIUM, ul. Nowodworska 11, 21-100 Lubartów","categories":["water"],"city":"Lubartów","imported_at":"2026-03-08T10:42:43.265Z","methods_count":35,"name":"Przedsiębiorstwo Gospodarki Komunalnej Sp. z o.o.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1310.pdf"],"scope_summary":"","search_text":"przedsiębiorstwo gospodarki komunalnej sp. z o.o. ul. parkowa 6, 21-100 lubartów, laboratorium, ul. nowodworska 11, 21-100 lubartów water other pharma electronics microbiology automotive","status":"active","updated_at":"2026-03-08T14:50:29.566Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:29.566Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201310,podmiot.html","parse_date":"2026-07-17T16:19:03.537Z","parse_source":"m5-mistral-qa","fields_of_testing":[{"codes":"C/28; C/29","pl":"Badania chemiczne wody i wody do spożycia przez ludzi","en":"Chemical tests of water and drinking water"},{"codes":"C/30/P","pl":"Badania chemiczne i pobieranie próbek ścieków","en":"Chemical tests and sampling of sewage"},{"codes":"N/28; N/29","pl":"Badania właściwości fizycznych wody i wody do spożycia przez ludzi","en":"Tests of physical properties of water and drinking water"},{"codes":"N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek ścieków","en":"Tests of physical properties and sampling of sewage"},{"codes":"K28; K/29","pl":"Badania mikrobiologiczne wody i wody do spożycia przez ludzi","en":"Microbiological tests of water and drinking water"}],"issue":{"no":"15","date":"17.11.2025"},"map_coord":[51.468444,22.614215],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":35,"microbiology":1},"category_scores":{"water":34.03,"microbiology":0.03},"has_zh":true},"methods":[{"_id":"6a5a55f79af9f73f38252136","lab_id":"69ad52a3de79e566650fb6ba","country":"PL","accr_number":"AB 1310","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna Metoda automatyczna","methodology_en":"Sampling for chemical and physical testing Manual method Automatic method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna Metoda automatyczna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych Metoda manualna Metoda automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Sampling for chemical and physical testing Manual method Automatic method PN-ISO 5667-10:2021-11","methodology_zh":"化学与物理检测用样品采集 手动法 自动法","search_zh":"污水 化学与物理检测用样品采集 手动法 自动法 PN-ISO 5667-10:2021-11","test_object_zh":"污水"},{"_id":"6a5a55f79af9f73f38252137","lab_id":"69ad52a3de79e566650fb6ba","country":"PL","accr_number":"AB 1310","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"pH Zakres: (2,0 – 10,0) Metoda potencjometryczna","methodology_en":"pH Range: (2,0 – 10,0) Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH Zakres: (2,0 – 10,0) Metoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki pH Zakres: (2,0 – 10,0) Metoda potencjometryczna PN-EN ISO 10523:2012 Scieki pH Zakres: (2,0 – 10,0) Metoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater pH Range: (2,0 – 10,0) Potentiometric method PN-EN ISO 10523:2012","search_zh":"污水 PN-EN ISO 10523:2012","test_object_zh":"污水"},{"_id":"6a5a55f79af9f73f38252138","lab_id":"69ad52a3de79e566650fb6ba","country":"PL","accr_number":"AB 1310","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Zawiesiny ogólne Zakres: (5,0 – 3 000) mg/l Metoda wagowa","methodology_en":"Total suspended solids Range: (5,0 – 3 000) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawiesiny ogólne Zakres: (5,0 – 3 000) mg/l Metoda wagowa","reference":"PN-EN 872:2007 +Ap1:2007","norm_bases":["PN-EN 872:2007 +Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Zawiesiny ogólne Zakres: (5,0 – 3 000) mg/l Metoda wagowa PN-EN 872:2007 +Ap1:2007 Scieki Zawiesiny ogolne Zakres: (5,0 – 3 000) mg/l Metoda wagowa PN-EN 872:2007 +Ap1:2007","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Total suspended solids Range: (5,0 – 3 000) mg/l Gravimetric method PN-EN 872:2007 +Ap1:2007","search_zh":"污水 PN-EN 872:2007 +Ap1:2007","test_object_zh":"污水"},{"_id":"6a5a55f79af9f73f38252139","lab_id":"69ad52a3de79e566650fb6ba","country":"PL","accr_number":"AB 1310","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT Zakres: (30,0 – 11 000) mg/l O 2 Metoda miareczkowa","methodology_en":"Chemical oxygen demand - COD Range: (30,0 – 11 000) mg/l O 2 Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT Zakres: (30,0 – 11 000) mg/l O 2 Metoda miareczkowa","reference":"PN-ISO 6060:2006","norm_bases":["PN-ISO 6060:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu - ChZT Zakres: (30,0 – 11 000) mg/l O 2 Metoda miareczkowa PN-ISO 6060:2006 Scieki Chemiczne zapotrzebowanie tlenu - ChZT Zakres: (30,0 – 11 000) mg/l O 2 Metoda miareczkowa PN-ISO 6060:2006","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Chemical oxygen demand - COD Range: (30,0 – 11 000) mg/l O 2 Titrimetric method PN-ISO 6060:2006","search_zh":"污水 PN-ISO 6060:2006","test_object_zh":"污水"},{"_id":"6a5a55f79af9f73f3825213a","lab_id":"69ad52a3de79e566650fb6ba","country":"PL","accr_number":"AB 1310","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (3 – 2 500) mg/l O 2 Metoda optyczna","methodology_en":"Biochemical oxygen demand - BOD 5 Range: (3 – 2 500) mg/l O 2 Optical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (3 – 2 500) mg/l O 2 Metoda optyczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (3 – 2 500) mg/l O 2 Metoda optyczna PN-EN ISO 5815-1:2019-12 Scieki Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (3 – 2 500) mg/l O 2 Metoda optyczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Biochemical oxygen demand - BOD 5 Range: (3 – 2 500) mg/l O 2 Optical method PN-EN ISO 5815-1:2019-12","search_zh":"污水 PN-EN ISO 5815-1:2019-12","test_object_zh":"污水"},{"_id":"6a5a55f79af9f73f3825213b","lab_id":"69ad52a3de79e566650fb6ba","country":"PL","accr_number":"AB 1310","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (0,5 – 6,0) mg/l O 2 Metoda optyczna","methodology_en":"Biochemical oxygen demand - BOD 5 Range: (0,5 – 6,0) mg/l O 2 Optical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (0,5 – 6,0) mg/l O 2 Metoda optyczna","reference":"PN-EN 1899-2:2002 z wył. p. 7.2.1 | Instrukcja Badawcza IB-01.00.00 wyd. 1 z dnia 19.09.2019 r.","norm_bases":["PN-EN 1899-2:2002 z wył. p. 7.2.1","Instrukcja Badawcza IB-01.00.00 wyd. 1 z dnia 19.09.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (0,5 – 6,0) mg/l O 2 Metoda optyczna PN-EN 1899-2:2002 z wył. p. 7.2.1 | Instrukcja Badawcza IB-01.00.00 wyd. 1 z dnia 19.09.2019 r. Scieki Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (0,5 – 6,0) mg/l O 2 Metoda optyczna PN-EN 1899-2:2002 z wyl. p. 7.2.1 | Instrukcja Badawcza IB-01.00.00 wyd. 1 z dnia 19.09.2019 r.","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Biochemical oxygen demand - BOD 5 Range: (0,5 – 6,0) mg/l O 2 Optical method PN-EN 1899-2:2002 z wył. p. 7.2.1 | Instrukcja Badawcza IB-01.00.00 wyd. 1 z dnia 19.09.2019 r.","search_zh":"污水 PN-EN 1899-2:2002 z wył. p. 7.2.1 | Instrukcja Badawcza IB-01.00.00 wyd. 1 z dnia 19.09.2019 r.","test_object_zh":"污水"},{"_id":"6a5a55f79af9f73f3825213c","lab_id":"69ad52a3de79e566650fb6ba","country":"PL","accr_number":"AB 1310","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie tlenu rozpuszczonego Zakres: (0,5 – 10,0) mg/l O 2 Metoda optyczna","methodology_en":"Dissolved oxygen concentration Range: (0,5 – 10,0) mg/l O 2 Optical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie tlenu rozpuszczonego Zakres: (0,5 – 10,0) mg/l O 2 Metoda optyczna","reference":"ISO 17289:2014","norm_bases":["ISO 17289:2014"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie tlenu rozpuszczonego Zakres: (0,5 – 10,0) mg/l O 2 Metoda optyczna ISO 17289:2014 Scieki Stezenie tlenu rozpuszczonego Zakres: (0,5 – 10,0) mg/l O 2 Metoda optyczna ISO 17289:2014","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Dissolved oxygen concentration Range: (0,5 – 10,0) mg/l O 2 Optical method ISO 17289:2014","search_zh":"污水 ISO 17289:2014","test_object_zh":"污水"},{"_id":"6a5a55f79af9f73f3825213d","lab_id":"69ad52a3de79e566650fb6ba","country":"PL","accr_number":"AB 1310","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu amonowego Zakres: (5,0 – 300 ) mg/l Metoda miareczkowa","methodology_en":"Ammonium nitrogen concentration Range: (5,0 – 300 ) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego Zakres: (5,0 – 300 ) mg/l Metoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu amonowego Zakres: (5,0 – 300 ) mg/l Metoda miareczkowa PN-ISO 5664:2002 Scieki Stezenie azotu amonowego Zakres: (5,0 – 300 ) mg/l Metoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Ammonium nitrogen concentration Range: (5,0 – 300 ) mg/l Titrimetric method PN-ISO 5664:2002","search_zh":"污水 PN-ISO 5664:2002","test_object_zh":"污水"},{"_id":"6a5a55f79af9f73f3825213e","lab_id":"69ad52a3de79e566650fb6ba","country":"PL","accr_number":"AB 1310","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu amonowego Zakres: (0,05 – 40,0) mg/l Metoda spektrofotometryczna","methodology_en":"Ammonium nitrogen concentration Range: (0,05 – 40,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego Zakres: (0,05 – 40,0) mg/l Metoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu amonowego Zakres: (0,05 – 40,0) mg/l Metoda spektrofotometryczna PN-ISO 7150-1:2002 Scieki Stezenie azotu amonowego Zakres: (0,05 – 40,0) mg/l Metoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Ammonium nitrogen concentration Range: (0,05 – 40,0) mg/l Spectrophotometric method PN-ISO 7150-1:2002","search_zh":"污水 PN-ISO 7150-1:2002","test_object_zh":"污水"},{"_id":"6a5a55f79af9f73f3825213f","lab_id":"69ad52a3de79e566650fb6ba","country":"PL","accr_number":"AB 1310","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu azotanowego Zakres: (0,10 – 30,0) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrate nitrogen concentration Range: (0,10 – 30,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu azotanowego Zakres: (0,10 – 30,0) mg/l Metoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu azotanowego Zakres: (0,10 – 30,0) mg/l Metoda spektrofotometryczna PN-82/C-04576.08 Scieki Stezenie azotu azotanowego Zakres: (0,10 – 30,0) mg/l Metoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Nitrate nitrogen concentration Range: (0,10 – 30,0) mg/l Spectrophotometric method PN-82/C-04576.08","search_zh":"污水 PN-82/C-04576.08","test_object_zh":"污水"},{"_id":"6a5a55f79af9f73f38252140","lab_id":"69ad52a3de79e566650fb6ba","country":"PL","accr_number":"AB 1310","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu azotynowego Zakres: (0,03 – 2,0) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrite nitrogen concentration Range: (0,03 – 2,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego Zakres: (0,03 – 2,0) mg/l Metoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu azotynowego Zakres: (0,03 – 2,0) mg/l Metoda spektrofotometryczna PN-EN 26777:1999 Scieki Stezenie azotu azotynowego Zakres: (0,03 – 2,0) mg/l Metoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Nitrite nitrogen concentration Range: (0,03 – 2,0) mg/l Spectrophotometric method PN-EN 26777:1999","search_zh":"污水 PN-EN 26777:1999","test_object_zh":"污水"},{"_id":"6a5a55f79af9f73f38252141","lab_id":"69ad52a3de79e566650fb6ba","country":"PL","accr_number":"AB 1310","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie chlorków Zakres: (5 – 1 000) mg/l Metoda miareczkowa","methodology_en":"Chloride concentration Range: (5 – 1 000) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chlorków Zakres: (5 – 1 000) mg/l Metoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie chlorków Zakres: (5 – 1 000) mg/l Metoda miareczkowa PN-ISO 9297:1994 Scieki Stezenie chlorkow Zakres: (5 – 1 000) mg/l Metoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Chloride concentration Range: (5 – 1 000) mg/l Titrimetric method PN-ISO 9297:1994","search_zh":"污水 PN-ISO 9297:1994","test_object_zh":"污水"},{"_id":"6a5a55f79af9f73f38252142","lab_id":"69ad52a3de79e566650fb6ba","country":"PL","accr_number":"AB 1310","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie fosforu ogólnego Zakres: (0,10 – 60,0) mg/l Metoda spektrofotometryczna","methodology_en":"Total phosphorus concentration Range: (0,10 – 60,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego Zakres: (0,10 – 60,0) mg/l Metoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 p. 7 +Ap1:2010 +Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 p. 7 +Ap1:2010 +Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie fosforu ogólnego Zakres: (0,10 – 60,0) mg/l Metoda spektrofotometryczna PN-EN ISO 6878:2006 p. 7 +Ap1:2010 +Ap2:2010 Scieki Stezenie fosforu ogolnego Zakres: (0,10 – 60,0) mg/l Metoda spektrofotometryczna PN-EN ISO 6878:2006 p. 7 +Ap1:2010 +Ap2:2010","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Total phosphorus concentration Range: (0,10 – 60,0) mg/l Spectrophotometric method PN-EN ISO 6878:2006 p. 7 +Ap1:2010 +Ap2:2010","search_zh":"污水 PN-EN ISO 6878:2006 p. 7 +Ap1:2010 +Ap2:2010","test_object_zh":"污水"},{"_id":"6a5a55f79af9f73f38252143","lab_id":"69ad52a3de79e566650fb6ba","country":"PL","accr_number":"AB 1310","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu ogólnego Kjeldahla Zakres: (2,00 – 500) mg/l Metoda miareczkowa","methodology_en":"Total Kjeldahl nitrogen concentration Range: (2,00 – 500) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego Kjeldahla Zakres: (2,00 – 500) mg/l Metoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu ogólnego Kjeldahla Zakres: (2,00 – 500) mg/l Metoda miareczkowa PN-EN 25663:2001 Scieki Stezenie azotu ogolnego Kjeldahla Zakres: (2,00 – 500) mg/l Metoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Total Kjeldahl nitrogen concentration Range: (2,00 – 500) mg/l Titrimetric method PN-EN 25663:2001","search_zh":"污水 PN-EN 25663:2001","test_object_zh":"污水"},{"_id":"6a5a55f79af9f73f38252144","lab_id":"69ad52a3de79e566650fb6ba","country":"PL","accr_number":"AB 1310","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu ogólnego (z obliczeń)","methodology_en":"Total nitrogen concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PN-73/C-04576.14","norm_bases":["PN-73/C-04576.14"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu ogólnego (z obliczeń) PN-73/C-04576.14 Scieki Stezenie azotu ogolnego (z obliczen) PN-73/C-04576.14","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Total nitrogen concentration (calculated) PN-73/C-04576.14","methodology_zh":"总氮浓度（计算值）","search_zh":"污水 总氮浓度（计算值） PN-73/C-04576.14","test_object_zh":"污水"},{"_id":"6a5a55f79af9f73f38252145","lab_id":"69ad52a3de79e566650fb6ba","country":"PL","accr_number":"AB 1310","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie siarczanów (VI) Zakres: (20 – 300) mg/l Metoda wagowa","methodology_en":"Sulfate (VI) concentration Range: (20 – 300) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie siarczanów (VI) Zakres: (20 – 300) mg/l Metoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie siarczanów (VI) Zakres: (20 – 300) mg/l Metoda wagowa PN-ISO 9280:2002 Scieki Stezenie siarczanow (VI) Zakres: (20 – 300) mg/l Metoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Sulfate (VI) concentration Range: (20 – 300) mg/l Gravimetric method PN-ISO 9280:2002","search_zh":"污水 PN-ISO 9280:2002","test_object_zh":"污水"},{"_id":"6a5a55f79af9f73f38252146","lab_id":"69ad52a3de79e566650fb6ba","country":"PL","accr_number":"AB 1310","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"pH Zakres: (2,0 – 10,0) Metoda potencjometryczna","methodology_en":"pH Range: (2,0 – 10,0) Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH Zakres: (2,0 – 10,0) Metoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda pH Zakres: (2,0 – 10,0) Metoda potencjometryczna PN-EN ISO 10523:2012 Woda pH Zakres: (2,0 – 10,0) Metoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water pH Range: (2,0 – 10,0) Potentiometric method PN-EN ISO 10523:2012","search_zh":"水 PN-EN ISO 10523:2012","test_object_zh":"水"},{"_id":"6a5a55f79af9f73f38252147","lab_id":"69ad52a3de79e566650fb6ba","country":"PL","accr_number":"AB 1310","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie azotu amonowego Zakres: (0,05 – 5,0) mg/l Metoda spektrofotometryczna","methodology_en":"Ammonium nitrogen concentration Range: (0,05 – 5,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego Zakres: (0,05 – 5,0) mg/l Metoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie azotu amonowego Zakres: (0,05 – 5,0) mg/l Metoda spektrofotometryczna PN-ISO 7150-1:2002 Woda Stezenie azotu amonowego Zakres: (0,05 – 5,0) mg/l Metoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Ammonium nitrogen concentration Range: (0,05 – 5,0) mg/l Spectrophotometric method PN-ISO 7150-1:2002","search_zh":"水 PN-ISO 7150-1:2002","test_object_zh":"水"},{"_id":"6a5a55f79af9f73f38252148","lab_id":"69ad52a3de79e566650fb6ba","country":"PL","accr_number":"AB 1310","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie jonu amonowego (z obliczeń)","methodology_en":"Ammonium ion concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie jonu amonowego (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie jonu amonowego (z obliczeń) Woda Stezenie jonu amonowego (z obliczen)","categories":["water"],"row_index":18,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Ammonium ion concentration (calculated)","search_zh":"水 铵离子浓度（由计算得出）","test_object_zh":"水","methodology_zh":"铵离子浓度（由计算得出）"},{"_id":"6a5a55f79af9f73f38252149","lab_id":"69ad52a3de79e566650fb6ba","country":"PL","accr_number":"AB 1310","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie azotu azotanowego Zakres: (0,05 – 10,0) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrate nitrogen concentration Range: (0,05 – 10,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu azotanowego Zakres: (0,05 – 10,0) mg/l Metoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie azotu azotanowego Zakres: (0,05 – 10,0) mg/l Metoda spektrofotometryczna PN-82/C-04576.08 Woda Stezenie azotu azotanowego Zakres: (0,05 – 10,0) mg/l Metoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":19,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Nitrate nitrogen concentration Range: (0,05 – 10,0) mg/l Spectrophotometric method PN-82/C-04576.08","search_zh":"水 PN-82/C-04576.08","test_object_zh":"水"},{"_id":"6a5a55f79af9f73f3825214a","lab_id":"69ad52a3de79e566650fb6ba","country":"PL","accr_number":"AB 1310","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie azotanów (z obliczeń)","methodology_en":"Nitrate concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotanów (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie azotanów (z obliczeń) Woda Stezenie azotanow (z obliczen)","categories":["water"],"row_index":20,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Nitrate concentration (calculated)","search_zh":"水 硝酸盐浓度（由计算得出）","test_object_zh":"水","methodology_zh":"硝酸盐浓度（由计算得出）"},{"_id":"6a5a55f79af9f73f3825214b","lab_id":"69ad52a3de79e566650fb6ba","country":"PL","accr_number":"AB 1310","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie azotu azotynowego Zakres: (0,003 – 2,0) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrite nitrogen concentration Range: (0,003 – 2,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego Zakres: (0,003 – 2,0) mg/l Metoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie azotu azotynowego Zakres: (0,003 – 2,0) mg/l Metoda spektrofotometryczna PN-EN 26777:1999 Woda Stezenie azotu azotynowego Zakres: (0,003 – 2,0) mg/l Metoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":21,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Nitrite nitrogen concentration Range: (0,003 – 2,0) mg/l Spectrophotometric method PN-EN 26777:1999","search_zh":"水 PN-EN 26777:1999","test_object_zh":"水"},{"_id":"6a5a55f79af9f73f3825214c","lab_id":"69ad52a3de79e566650fb6ba","country":"PL","accr_number":"AB 1310","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie azotynów (z obliczeń)","methodology_en":"Nitrite concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotynów (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie azotynów (z obliczeń) Woda Stezenie azotynow (z obliczen)","categories":["water"],"row_index":22,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Nitrite concentration (calculated)","search_zh":"水 亚硝酸盐浓度（由计算得出）","test_object_zh":"水","methodology_zh":"亚硝酸盐浓度（由计算得出）"},{"_id":"6a5a55f79af9f73f3825214d","lab_id":"69ad52a3de79e566650fb6ba","country":"PL","accr_number":"AB 1310","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie chlorków Zakres: (5 – 200) mg/l Metoda miareczkowa","methodology_en":"Chloride concentration Range: (5 – 200) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chlorków Zakres: (5 – 200) mg/l Metoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie chlorków Zakres: (5 – 200) mg/l Metoda miareczkowa PN-ISO 9297:1994 Woda Stezenie chlorkow Zakres: (5 – 200) mg/l Metoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":23,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Chloride concentration Range: (5 – 200) mg/l Titrimetric method PN-ISO 9297:1994","search_zh":"水 PN-ISO 9297:1994","test_object_zh":"水"},{"_id":"6a5a55f79af9f73f3825214e","lab_id":"69ad52a3de79e566650fb6ba","country":"PL","accr_number":"AB 1310","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Mętność Zakres: (0,2 – 10,0) NTU Metoda nefelometryczna","methodology_en":"Turbidity Range: (0,2 – 10,0) NTU Nephelometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Mętność Zakres: (0,2 – 10,0) NTU Metoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Mętność Zakres: (0,2 – 10,0) NTU Metoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda Metnosc Zakres: (0,2 – 10,0) NTU Metoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":24,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Turbidity Range: (0,2 – 10,0) NTU Nephelometric method PN-EN ISO 7027-1:2016-09","search_zh":"水 PN-EN ISO 7027-1:2016-09","test_object_zh":"水"},{"_id":"6a5a55f79af9f73f3825214f","lab_id":"69ad52a3de79e566650fb6ba","country":"PL","accr_number":"AB 1310","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Przewodność elektryczna właściwa Zakres: (150 – 1 500) µS/cm Metoda konduktometryczna","methodology_en":"Electrical conductivity Range: (150 – 1 500) µS/cm Conductometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa Zakres: (150 – 1 500) µS/cm Metoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Przewodność elektryczna właściwa Zakres: (150 – 1 500) µS/cm Metoda konduktometryczna PN-EN 27888:1999 Woda Przewodnosc elektryczna wlasciwa Zakres: (150 – 1 500) µS/cm Metoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":25,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Electrical conductivity Range: (150 – 1 500) µS/cm Conductometric method PN-EN 27888:1999","search_zh":"水 PN-EN 27888:1999","test_object_zh":"水"},{"_id":"6a5a55f79af9f73f38252150","lab_id":"69ad52a3de79e566650fb6ba","country":"PL","accr_number":"AB 1310","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie manganu Zakres: (20,0 – 15 000) µg/l Metoda spektrofotometryczna","methodology_en":"Manganese concentration Range: (20,0 – 15 000) µg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie manganu Zakres: (20,0 – 15 000) µg/l Metoda spektrofotometryczna","reference":"PN-C-04590.02:1992","norm_bases":["PN-C-04590.02:1992"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie manganu Zakres: (20,0 – 15 000) µg/l Metoda spektrofotometryczna PN-C-04590.02:1992 Woda Stezenie manganu Zakres: (20,0 – 15 000) µg/l Metoda spektrofotometryczna PN-C-04590.02:1992","categories":["water"],"row_index":26,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Manganese concentration Range: (20,0 – 15 000) µg/l Spectrophotometric method PN-C-04590.02:1992","search_zh":"水 PN-C-04590.02:1992","test_object_zh":"水"},{"_id":"6a5a55f79af9f73f38252151","lab_id":"69ad52a3de79e566650fb6ba","country":"PL","accr_number":"AB 1310","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie żelaza ogólnego Zakres: (30 – 10 000) µg/l Metoda spektrofotometryczna","methodology_en":"Total iron concentration Range: (30 – 10 000) µg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie żelaza ogólnego Zakres: (30 – 10 000) µg/l Metoda spektrofotometryczna","reference":"PN-ISO 6332:2001 p.7.1 +Ap1:2016-06","norm_bases":["PN-ISO 6332:2001 p.7.1 +Ap1:2016-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie żelaza ogólnego Zakres: (30 – 10 000) µg/l Metoda spektrofotometryczna PN-ISO 6332:2001 p.7.1 +Ap1:2016-06 Woda Stezenie zelaza ogolnego Zakres: (30 – 10 000) µg/l Metoda spektrofotometryczna PN-ISO 6332:2001 p.7.1 +Ap1:2016-06","categories":["water"],"row_index":27,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Total iron concentration Range: (30 – 10 000) µg/l Spectrophotometric method PN-ISO 6332:2001 p.7.1 +Ap1:2016-06","search_zh":"水 PN-ISO 6332:2001 p.7.1 +Ap1:2016-06","test_object_zh":"水"},{"_id":"6a5a55f79af9f73f38252152","lab_id":"69ad52a3de79e566650fb6ba","country":"PL","accr_number":"AB 1310","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Sumaryczna zawartość wapnia i magnezu (Twardość ogólna) Zakres: (5 – 500)mg/l CaCO 3 Metoda miareczkowa","methodology_en":"Total calcium and magnesium content (Total hardness) Range: (5 – 500)mg/l CaCO 3 Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Sumaryczna zawartość wapnia i magnezu (Twardość ogólna) Zakres: (5 – 500)mg/l CaCO 3 Metoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Sumaryczna zawartość wapnia i magnezu (Twardość ogólna) Zakres: (5 – 500)mg/l CaCO 3 Metoda miareczkowa PN-ISO 6059:1999 Woda Sumaryczna zawartosc wapnia i magnezu (Twardosc ogolna) Zakres: (5 – 500)mg/l CaCO 3 Metoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":28,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Total calcium and magnesium content (Total hardness) Range: (5 – 500)mg/l CaCO 3 Titrimetric method PN-ISO 6059:1999","search_zh":"水 PN-ISO 6059:1999","test_object_zh":"水"},{"_id":"6a5a55f79af9f73f38252153","lab_id":"69ad52a3de79e566650fb6ba","country":"PL","accr_number":"AB 1310","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Indeks nadmanganianowy Zakres: (0,5 – 10,0) mg/l O 2 Metoda miareczkowa","methodology_en":"Permanganate index Range: (0,5 – 10,0) mg/l O 2 Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Indeks nadmanganianowy Zakres: (0,5 – 10,0) mg/l O 2 Metoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Indeks nadmanganianowy Zakres: (0,5 – 10,0) mg/l O 2 Metoda miareczkowa PN-EN ISO 8467:2001 Woda Indeks nadmanganianowy Zakres: (0,5 – 10,0) mg/l O 2 Metoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":29,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Permanganate index Range: (0,5 – 10,0) mg/l O 2 Titrimetric method PN-EN ISO 8467:2001","search_zh":"水 PN-EN ISO 8467:2001","test_object_zh":"水"},{"_id":"6a5a55f79af9f73f38252154","lab_id":"69ad52a3de79e566650fb6ba","country":"PL","accr_number":"AB 1310","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Barwa Zakres: (5,0 – 50,0) mg/l Pt Metoda spektrofotometryczna","methodology_en":"Colour Range: (5,0 – 50,0) mg/l Pt Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Barwa Zakres: (5,0 – 50,0) mg/l Pt Metoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 p. 6 +Ap1:2015-06","norm_bases":["PN-EN ISO 7887:2012 p. 6 +Ap1:2015-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Barwa Zakres: (5,0 – 50,0) mg/l Pt Metoda spektrofotometryczna PN-EN ISO 7887:2012 p. 6 +Ap1:2015-06 Woda Barwa Zakres: (5,0 – 50,0) mg/l Pt Metoda spektrofotometryczna PN-EN ISO 7887:2012 p. 6 +Ap1:2015-06","categories":["water"],"row_index":30,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Colour Range: (5,0 – 50,0) mg/l Pt Spectrophotometric method PN-EN ISO 7887:2012 p. 6 +Ap1:2015-06","search_zh":"水 PN-EN ISO 7887:2012 p. 6 +Ap1:2015-06","test_object_zh":"水"},{"_id":"6a5a55f79af9f73f38252155","lab_id":"69ad52a3de79e566650fb6ba","country":"PL","accr_number":"AB 1310","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie siarczanów (VI) Zakres: (20 – 300) mg/l Metoda wagowa","methodology_en":"Sulfate (VI) concentration Range: (20 – 300) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie siarczanów (VI) Zakres: (20 – 300) mg/l Metoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie siarczanów (VI) Zakres: (20 – 300) mg/l Metoda wagowa PN-ISO 9280:2002 Woda Stezenie siarczanow (VI) Zakres: (20 – 300) mg/l Metoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":31,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Sulfate (VI) concentration Range: (20 – 300) mg/l Gravimetric method PN-ISO 9280:2002","search_zh":"水 PN-ISO 9280:2002","test_object_zh":"水"},{"_id":"6a5a55f79af9f73f38252156","lab_id":"69ad52a3de79e566650fb6ba","country":"PL","accr_number":"AB 1310","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Ogólna liczba mikroorganizmów inkubowanych w temperaturze 22°C i 36°C Metoda płytkowa (posiew wgłębny)","methodology_en":"Total count of microorganisms incubated at 22°C and 36°C Plate method (pour plate)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów inkubowanych w temperaturze 22°C i 36°C Metoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ogólna liczba mikroorganizmów inkubowanych w temperaturze 22°C i 36°C Metoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda Ogolna liczba mikroorganizmow inkubowanych w temperaturze 22°C i 36°C Metoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":32,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Total count of microorganisms incubated at 22°C and 36°C Plate method (pour plate) PN-EN ISO 6222:2004","search_zh":"水 PN-EN ISO 6222:2004","test_object_zh":"水"},{"_id":"6a5a55f79af9f73f38252157","lab_id":"69ad52a3de79e566650fb6ba","country":"PL","accr_number":"AB 1310","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Obecność i liczba enterokoków (paciorkowców kałowych) Metoda filtracji membranowej","methodology_en":"Presence and count of enterococci (faecal streptococci) Membrane filtration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Obecność i liczba enterokoków (paciorkowców kałowych) Metoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Obecność i liczba enterokoków (paciorkowców kałowych) Metoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda Obecnosc i liczba enterokokow (paciorkowcow kalowych) Metoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":33,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Presence and count of enterococci (faecal streptococci) Membrane filtration method PN-EN ISO 7899-2:2004","search_zh":"水 PN-EN ISO 7899-2:2004","test_object_zh":"水"},{"_id":"6a5a55f79af9f73f38252158","lab_id":"69ad52a3de79e566650fb6ba","country":"PL","accr_number":"AB 1310","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Obecność i liczba Escherichia coli i bakterii grupy coli Metoda filtracji membranowej","methodology_en":"Presence and number of Escherichia coli and coliform bacteria Membrane filtration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Obecność i liczba Escherichia coli i bakterii grupy coli Metoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014+A1:2017","norm_bases":["PN-EN ISO 9308-1:2014+A1:2017"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Obecność i liczba Escherichia coli i bakterii grupy coli Metoda filtracji membranowej PN-EN ISO 9308-1:2014+A1:2017 Woda Obecnosc i liczba Escherichia coli i bakterii grupy coli Metoda filtracji membranowej PN-EN ISO 9308-1:2014+A1:2017","categories":["microbiology","water"],"row_index":34,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Presence and number of Escherichia coli and coliform bacteria Membrane filtration method PN-EN ISO 9308-1:2014+A1:2017","search_zh":"水 PN-EN ISO 9308-1:2014+A1:2017","test_object_zh":"水"}],"has_pdf":true}