🇵🇱 CENTRUM BADAWCZO-ANALITYCZNE MLEKA Sp. z o.o. PL
Food & beveragesMicrobiology
CENTRUM BADAWCZO-ANALITYCZNE MLEKA Sp. z o.o. is a laboratory accredited by PCA under number AB 1309 (Grajewo, Poland). Its accreditation scope covers 9 test methods in the following areas: Food & beverages, Microbiology. Test objects include: Raw milk.
At a glance
- Accreditation number: PCA AB 1309
- Methods in scope: 9
- Types of test objects: 1
- City: Grajewo, Poland
- Accreditation number
- AB 1309
- Accreditation body
- PCA
- Address
- ul. Elewatorska 13, 19-203 Grajewo
- City
- Grajewo, Poland
What this laboratory tests (1)
- Raw milk — 9 methods
Accreditation scope — test methods (9)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Raw milk | Fat content Range: (1,5 – 5,5) % Infrared spectrometry method | PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan FT+ | ||
| 2 | Raw milk | Protein content Range: (2,0 – 5,0) % Infrared spectrometry method | |||
| 3 | Raw milk | Lactose content Range: (4,0 – 5,5) % Infrared spectrometry method | |||
| 4 | Raw milk | Urea content Range: (100 – 500) mg/l Infrared spectrometry method | PB-10.00 wydanie nr 01 z 11.01.2018 r. w oparciu o instrukcję aparatu Milkoscan FT+ | ||
| 5 | Raw milk | Somatic cell count Range (1x103 – 2x106) cells/ml Flow cytometry method | PN-EN ISO 13366-2:2007 z zastosowaniem aparatu Fossomatic 5000 | ||
| 6 | Raw milk | Total viable count Range: (1x103 – 10x106 ) CFU/ml Flow cytometry method | PB-03.00 wydanie nr 03 z 01.08.2024 r. w oparciu o instrukcję aparatu Bactoscan FC | ||
| 7 | Raw milk | Freezing point of milk Range: (-0,408° C) − (-0,600 °C) Cryoscopic method | PN-EN ISO 5764:2010 z zastosowaniem aparatu Krioskop 4250 | ||
| 8 | Raw milk | Presence of antibiotics and other inhibitory substances Diffusion method | PB-12.00 wydanie nr 01 z 30.03.2018 r. w oparciu o instrukcję producenta testu Delvotest SP-NT | ||
| 9 | Raw milk | Presence of β-lactam antibiotics and tetracyclines Receptor method | PB-11.00 wydanie nr 01 z 30.03.2018 r. w oparciu o instrukcję producenta testu Charm MRLBLRFTET2 | ||
Reference standards (7)
PB-03.00 wydanie nr 03 z 01.08.2024 r. w oparciu o instrukcję aparatu Bactoscan FC
PB-10.00 wydanie nr 01 z 11.01.2018 r. w oparciu o instrukcję aparatu Milkoscan FT+
PB-11.00 wydanie nr 01 z 30.03.2018 r. w oparciu o instrukcję producenta testu Charm MRLBLRFTET2
PB-12.00 wydanie nr 01 z 30.03.2018 r. w oparciu o instrukcję producenta testu Delvotest SP-NT
PN-EN ISO 13366-2:2007 z zastosowaniem aparatu Fossomatic 5000
PN-EN ISO 5764:2010 z zastosowaniem aparatu Krioskop 4250
PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan FT+