{"lab":{"_id":"69ad52a3de79e566650fb6b8","accr_number":"AB 1309","country":"PL","accr_body":"PCA","address":"ul. Elewatorska 13, 19-203 Grajewo","categories":["food","microbiology"],"city":"Grajewo","imported_at":"2026-03-08T10:42:43.265Z","methods_count":9,"name":"CENTRUM BADAWCZO-ANALITYCZNE MLEKA Sp. z o.o.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1309.pdf"],"scope_summary":"","search_text":"centrum badawczo-analityczne mleka sp. z o.o. ul. elewatorska 13, 19-203 grajewo other food pharma microbiology","status":"active","updated_at":"2026-03-08T14:50:29.502Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:29.502Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201309,podmiot.html","parse_date":"2026-07-17T16:19:03.521Z","parse_source":"m5-mistral-qa","fields_of_testing":[{"codes":"B/22","pl":"Badania biochemiczne żywności","en":"Biochemical tests of food"},{"codes":"C/22","pl":"Badania chemiczne żywności","en":"Chemical tests of food"},{"codes":"K/22","pl":"Badania mikrobiologiczne żywności","en":"Microbiological tests of food"},{"codes":"N/22","pl":"Badania właściwości fizycznych żywności","en":"Tests of physical properties of food"}],"issue":{"no":"13","date":"12.11.2024"},"map_coord":[53.630133,22.472702],"map_geo":"nominatim-street","has_en":true,"category_counts":{"food":9,"microbiology":1},"category_scores":{"food":8.1,"microbiology":0.1},"has_zh":true},"methods":[{"_id":"6a5a55f79af9f73f3825212d","lab_id":"69ad52a3de79e566650fb6b8","country":"PL","accr_number":"AB 1309","accr_body":"PCA","test_object":"Mleko surowe","test_object_en":"Raw milk","methodology":"Zawartość tłuszczu Zakres: (1,5 – 5,5) % Metoda spektrometrii w podczerwieni","methodology_en":"Fat content Range: (1,5 – 5,5) % Infrared spectrometry method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość tłuszczu Zakres: (1,5 – 5,5) % Metoda spektrometrii w podczerwieni","reference":"PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan FT+","norm_bases":["PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan FT+"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mleko surowe Zawartość tłuszczu Zakres: (1,5 – 5,5) % Metoda spektrometrii w podczerwieni PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan FT+ Mleko surowe Zawartosc tluszczu Zakres: (1,5 – 5,5) % Metoda spektrometrii w podczerwieni PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan FT+","categories":["food"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Raw milk Fat content Range: (1,5 – 5,5) % Infrared spectrometry method PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan FT+","search_zh":"生乳 PN-ISO 9622:2015-09 z zastosowaniem aparatu Milkoscan FT+","test_object_zh":"生乳"},{"_id":"6a5a55f79af9f73f3825212e","lab_id":"69ad52a3de79e566650fb6b8","country":"PL","accr_number":"AB 1309","accr_body":"PCA","test_object":"Mleko surowe","test_object_en":"Raw milk","methodology":"Zawartość białka Zakres: (2,0 – 5,0) % Metoda spektrometrii w podczerwieni","methodology_en":"Protein content Range: (2,0 – 5,0) % Infrared spectrometry method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość białka Zakres: (2,0 – 5,0) % Metoda spektrometrii w podczerwieni","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mleko surowe Zawartość białka Zakres: (2,0 – 5,0) % Metoda spektrometrii w podczerwieni Mleko surowe Zawartosc bialka Zakres: (2,0 – 5,0) % Metoda spektrometrii w podczerwieni","categories":["food"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Raw milk Protein content Range: (2,0 – 5,0) % Infrared spectrometry method","search_zh":"生乳","test_object_zh":"生乳"},{"_id":"6a5a55f79af9f73f3825212f","lab_id":"69ad52a3de79e566650fb6b8","country":"PL","accr_number":"AB 1309","accr_body":"PCA","test_object":"Mleko surowe","test_object_en":"Raw milk","methodology":"Zawartość laktozy Zakres: (4,0 – 5,5) % Metoda spektrometrii w podczerwieni","methodology_en":"Lactose content Range: (4,0 – 5,5) % Infrared spectrometry method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość laktozy Zakres: (4,0 – 5,5) % Metoda spektrometrii w podczerwieni","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mleko surowe Zawartość laktozy Zakres: (4,0 – 5,5) % Metoda spektrometrii w podczerwieni Mleko surowe Zawartosc laktozy Zakres: (4,0 – 5,5) % Metoda spektrometrii w podczerwieni","categories":["food"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Raw milk Lactose content Range: (4,0 – 5,5) % Infrared spectrometry method","search_zh":"生乳","test_object_zh":"生乳"},{"_id":"6a5a55f79af9f73f38252130","lab_id":"69ad52a3de79e566650fb6b8","country":"PL","accr_number":"AB 1309","accr_body":"PCA","test_object":"Mleko surowe","test_object_en":"Raw milk","methodology":"Zawartość mocznika Zakres: (100 – 500) mg/l Metoda spektrometrii w podczerwieni","methodology_en":"Urea content Range: (100 – 500) mg/l Infrared spectrometry method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość mocznika Zakres: (100 – 500) mg/l Metoda spektrometrii w podczerwieni","reference":"PB-10.00 wydanie nr 01 z 11.01.2018 r. w oparciu o instrukcję aparatu Milkoscan FT+","norm_bases":["PB-10.00 wydanie nr 01 z 11.01.2018 r. w oparciu o instrukcję aparatu Milkoscan FT+"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mleko surowe Zawartość mocznika Zakres: (100 – 500) mg/l Metoda spektrometrii w podczerwieni PB-10.00 wydanie nr 01 z 11.01.2018 r. w oparciu o instrukcję aparatu Milkoscan FT+ Mleko surowe Zawartosc mocznika Zakres: (100 – 500) mg/l Metoda spektrometrii w podczerwieni PB-10.00 wydanie nr 01 z 11.01.2018 r. w oparciu o instrukcje aparatu Milkoscan FT+","categories":["food"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Raw milk Urea content Range: (100 – 500) mg/l Infrared spectrometry method PB-10.00 wydanie nr 01 z 11.01.2018 r. w oparciu o instrukcję aparatu Milkoscan FT+","search_zh":"生乳 PB-10.00 wydanie nr 01 z 11.01.2018 r. w oparciu o instrukcję aparatu Milkoscan FT+","test_object_zh":"生乳"},{"_id":"6a5a55f79af9f73f38252131","lab_id":"69ad52a3de79e566650fb6b8","country":"PL","accr_number":"AB 1309","accr_body":"PCA","test_object":"Mleko surowe","test_object_en":"Raw milk","methodology":"Liczba komórek somatycznych Zakres (1x103 – 2x106) komórek/ml Metoda cytometrii przepływowej","methodology_en":"Somatic cell count Range (1x103 – 2x106) cells/ml Flow cytometry method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba komórek somatycznych Zakres (1x103 – 2x106) komórek/ml Metoda cytometrii przepływowej","reference":"PN-EN ISO 13366-2:2007 z zastosowaniem aparatu Fossomatic 5000","norm_bases":["PN-EN ISO 13366-2:2007 z zastosowaniem aparatu Fossomatic 5000"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mleko surowe Liczba komórek somatycznych Zakres (1x103 – 2x106) komórek/ml Metoda cytometrii przepływowej PN-EN ISO 13366-2:2007 z zastosowaniem aparatu Fossomatic 5000 Mleko surowe Liczba komorek somatycznych Zakres (1x103 – 2x106) komorek/ml Metoda cytometrii przeplywowej PN-EN ISO 13366-2:2007 z zastosowaniem aparatu Fossomatic 5000","categories":["food"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Raw milk Somatic cell count Range (1x103 – 2x106) cells/ml Flow cytometry method PN-EN ISO 13366-2:2007 z zastosowaniem aparatu Fossomatic 5000","search_zh":"生乳 PN-EN ISO 13366-2:2007 z zastosowaniem aparatu Fossomatic 5000","test_object_zh":"生乳"},{"_id":"6a5a55f79af9f73f38252132","lab_id":"69ad52a3de79e566650fb6b8","country":"PL","accr_number":"AB 1309","accr_body":"PCA","test_object":"Mleko surowe","test_object_en":"Raw milk","methodology":"Ogólna liczba drobnoustrojów Zakres: (1x103 – 10x106 ) jtk/ml Metoda cytometrii przepływowej","methodology_en":"Total viable count Range: (1x103 – 10x106 ) CFU/ml Flow cytometry method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ogólna liczba drobnoustrojów Zakres: (1x103 – 10x106 ) jtk/ml Metoda cytometrii przepływowej","reference":"PB-03.00 wydanie nr 03 z 01.08.2024 r. w oparciu o instrukcję aparatu Bactoscan FC","norm_bases":["PB-03.00 wydanie nr 03 z 01.08.2024 r. w oparciu o instrukcję aparatu Bactoscan FC"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mleko surowe Ogólna liczba drobnoustrojów Zakres: (1x103 – 10x106 ) jtk/ml Metoda cytometrii przepływowej PB-03.00 wydanie nr 03 z 01.08.2024 r. w oparciu o instrukcję aparatu Bactoscan FC Mleko surowe Ogolna liczba drobnoustrojow Zakres: (1x103 – 10x106 ) jtk/ml Metoda cytometrii przeplywowej PB-03.00 wydanie nr 03 z 01.08.2024 r. w oparciu o instrukcje aparatu Bactoscan FC","categories":["food","microbiology"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Raw milk Total viable count Range: (1x103 – 10x106 ) CFU/ml Flow cytometry method PB-03.00 wydanie nr 03 z 01.08.2024 r. w oparciu o instrukcję aparatu Bactoscan FC","search_zh":"生乳 PB-03.00 wydanie nr 03 z 01.08.2024 r. w oparciu o instrukcję aparatu Bactoscan FC","test_object_zh":"生乳"},{"_id":"6a5a55f79af9f73f38252133","lab_id":"69ad52a3de79e566650fb6b8","country":"PL","accr_number":"AB 1309","accr_body":"PCA","test_object":"Mleko surowe","test_object_en":"Raw milk","methodology":"Punkt zamarzania mleka Zakres: (-0,408° C) − (-0,600 °C) Metoda krioskopowa","methodology_en":"Freezing point of milk Range: (-0,408° C) − (-0,600 °C) Cryoscopic method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Punkt zamarzania mleka Zakres: (-0,408° C) − (-0,600 °C) Metoda krioskopowa","reference":"PN-EN ISO 5764:2010 z zastosowaniem aparatu Krioskop 4250","norm_bases":["PN-EN ISO 5764:2010 z zastosowaniem aparatu Krioskop 4250"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mleko surowe Punkt zamarzania mleka Zakres: (-0,408° C) − (-0,600 °C) Metoda krioskopowa PN-EN ISO 5764:2010 z zastosowaniem aparatu Krioskop 4250 Mleko surowe Punkt zamarzania mleka Zakres: (-0,408° C) − (-0,600 °C) Metoda krioskopowa PN-EN ISO 5764:2010 z zastosowaniem aparatu Krioskop 4250","categories":["food"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Raw milk Freezing point of milk Range: (-0,408° C) − (-0,600 °C) Cryoscopic method PN-EN ISO 5764:2010 z zastosowaniem aparatu Krioskop 4250","search_zh":"生乳 PN-EN ISO 5764:2010 z zastosowaniem aparatu Krioskop 4250","test_object_zh":"生乳"},{"_id":"6a5a55f79af9f73f38252134","lab_id":"69ad52a3de79e566650fb6b8","country":"PL","accr_number":"AB 1309","accr_body":"PCA","test_object":"Mleko surowe","test_object_en":"Raw milk","methodology":"Obecność antybiotyków i innych substancji hamujących Metoda dyfuzyjna","methodology_en":"Presence of antibiotics and other inhibitory substances Diffusion method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Obecność antybiotyków i innych substancji hamujących Metoda dyfuzyjna","reference":"PB-12.00 wydanie nr 01 z 30.03.2018 r. w oparciu o instrukcję producenta testu Delvotest SP-NT","norm_bases":["PB-12.00 wydanie nr 01 z 30.03.2018 r. w oparciu o instrukcję producenta testu Delvotest SP-NT"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mleko surowe Obecność antybiotyków i innych substancji hamujących Metoda dyfuzyjna PB-12.00 wydanie nr 01 z 30.03.2018 r. w oparciu o instrukcję producenta testu Delvotest SP-NT Mleko surowe Obecnosc antybiotykow i innych substancji hamujacych Metoda dyfuzyjna PB-12.00 wydanie nr 01 z 30.03.2018 r. w oparciu o instrukcje producenta testu Delvotest SP-NT","categories":["food"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Raw milk Presence of antibiotics and other inhibitory substances Diffusion method PB-12.00 wydanie nr 01 z 30.03.2018 r. w oparciu o instrukcję producenta testu Delvotest SP-NT","search_zh":"生乳 PB-12.00 wydanie nr 01 z 30.03.2018 r. w oparciu o instrukcję producenta testu Delvotest SP-NT","test_object_zh":"生乳"},{"_id":"6a5a55f79af9f73f38252135","lab_id":"69ad52a3de79e566650fb6b8","country":"PL","accr_number":"AB 1309","accr_body":"PCA","test_object":"Mleko surowe","test_object_en":"Raw milk","methodology":"Obecność antybiotyków β-laktamowych i tetracyklin Metoda receptorowa","methodology_en":"Presence of β-lactam antibiotics and tetracyclines Receptor method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Obecność antybiotyków β-laktamowych i tetracyklin Metoda receptorowa","reference":"PB-11.00 wydanie nr 01 z 30.03.2018 r. w oparciu o instrukcję producenta testu Charm MRLBLRFTET2","norm_bases":["PB-11.00 wydanie nr 01 z 30.03.2018 r. w oparciu o instrukcję producenta testu Charm MRLBLRFTET2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Mleko surowe Obecność antybiotyków β-laktamowych i tetracyklin Metoda receptorowa PB-11.00 wydanie nr 01 z 30.03.2018 r. w oparciu o instrukcję producenta testu Charm MRLBLRFTET2 Mleko surowe Obecnosc antybiotykow β-laktamowych i tetracyklin Metoda receptorowa PB-11.00 wydanie nr 01 z 30.03.2018 r. w oparciu o instrukcje producenta testu Charm MRLBLRFTET2","categories":["food"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Raw milk Presence of β-lactam antibiotics and tetracyclines Receptor method PB-11.00 wydanie nr 01 z 30.03.2018 r. w oparciu o instrukcję producenta testu Charm MRLBLRFTET2","search_zh":"生乳 PB-11.00 wydanie nr 01 z 30.03.2018 r. w oparciu o instrukcję producenta testu Charm MRLBLRFTET2","test_object_zh":"生乳"}],"has_pdf":true}