🇵🇱 Tokai COBEX Polska spółka z o.o. PL

PCA AB 1305 • Nowy Sącz, Poland • 31 methods

Environment

Tokai COBEX Polska spółka z o.o. is a laboratory accredited by PCA under number AB 1305 (Nowy Sącz, Poland). Its accreditation scope covers 31 test methods in the following areas: Environment. Test objects include: Waste gases, Workplace environment - air, General environment – noise from installations, equipment and indus…, Workplace environment - energy expenditure.

At a glance

  • Accreditation number: PCA AB 1305
  • Methods in scope: 31
  • Types of test objects: 5
  • City: Nowy Sącz, Poland
Accreditation number
AB 1305
Accreditation body
PCA
Address
ul. Piastowska 29, 47-400 Racibórz, LABORATORIUM OCHRONY ŚRODOWISKA LDS, ul. Węgierska 188, 33-300 Nowy Sącz
City
Nowy Sącz, Poland

What this laboratory tests (5)

Accreditation scope — test methods (31)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Waste gases Gas volume flow rate for dynamic pressures > 10 Pa Pitot tube method PN-Z-04030-7:1994
2 Waste gases Sampling for determination of dust concentration
3 Waste gases Dust concentration Range: (0,001 – 100) g/m3 Gravimetric method
4 Waste gases Dust emission (calculated)
5 Waste gases Sampling for determination of dust concentration PN-EN 13284-1:2018-02
6 Waste gases Dust concentration Range: (0,001 – 0,05) g/m3 Gravimetric method
7 Waste gases Dust emission (calculated) PN-ISO 10396:2001
8 Waste gases Concentration of carbon monoxide, carbon dioxide, sulphur dioxide, nitrogen monoxide, nitrogen oxides, oxygen Range: - CO (5,0 – 1000) mg/m3 - CO (0,1 – 15) % 2 - SO (10 – 450) mg/m3 2 Non-dispersive infrared absorption method (NDIR) - NO (2,0 – 180) mg/m3 - NO (3,0 – 280) mg/m3 x Chemiluminescence method (CLD) - O (0,5 – 21) % 2 Paramagnetic method (PMD)
9 Waste gases Emission of CO, CO , SO , NO, NO 2 2 x (NO calculated as NO ) x 2 (calculated)
10 Waste gases Concentration of nitrogen monoxide, nitrogen oxides Range: - NO (2,0 – 180) mg/m3 - NO (3,0 – 280) mg/m3 x Chemiluminescence method (CLD) PN-EN 14792:2017-04
11 Waste gases Emission of NO, NO (NO calculated x x as NO ) 2 (calculated)
12 Waste gases Sampling for determination of the concentrations of organic compounds Aspiration method using activated carbon, silica gel, absorbing solutions PN-Z-04008-4:1999
13 Waste gases Emission of organic compounds (calculated)
14 Waste gases Concentration of organic substances in gaseous and vapour form expressed as total gaseous organic carbon Range: (4,0 – 800) mg/m3 Continuous flame ionisation detection method (FID) PN-EN 12619:2013-05
15 Waste gases Emission of organic substances in gaseous and vapour form expressed as total gaseous organic carbon (calculated)
16 Waste gases Sampling for determination of the concentration of individual gaseous organic compounds PN-EN 13649:2005
17 Waste gases Emission of individual gaseous organic compounds (calculated)
18 Waste gases Sampling for determination of the mass concentration of PAH Filtration-condensation-adsorption method ISO 11338-1:2003 – Metoda C
19 Waste gases PAH emission (calculated)
20 Waste gases Sampling for determination of the concentration of dust fractions PM 2,5 and PM 10 PN-EN 13284-1:2018-02 PN-Z-04030-7:1994 IB/08 z dnia 20.01.2020 r.
21 General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound level Range: (23 – 130) dB Direct measurement method nr 7 | enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 | eniem punktów E.II.1 i F
22 General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound level for reference time T expressed as L and L AeqD AeqN indices (calculated)
23 Workplace environment - noise A-weighted equivalent sound level A-weighted maximum sound level Range: (30 – 136) dB C-weighted peak sound level Range: (30 – 136) dB Direct measurement method PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 3 – punkt 11
24 Workplace environment - noise Noise exposure level referred to: - the 8-hour daily working time - the average weekly working time (calculated)
25 Workplace environment - air Sampling for occupational exposure assessment to: - industrial dusts – inhalable fraction – respirable fraction - inorganic substances – respirable fraction Personal dosimetry method PN-Z-04008-7:2002 PN-Z-04008-7:2002+Az1:2004
26 Workplace environment - air Exposure index (calculated)
27 Workplace environment - air Sampling for occupational exposure assessment and determination of polycyclic aromatic hydrocarbons Personal dosimetry method PN-Z-04008-7:2002 PN-Z-04240-5:2006 punkt 7
28 Workplace environment - air Concentration of harmful dust agents – inhalable fraction - natural graphite - synthetic graphite - amorphous and synthetic silica - wood dust - dusts not classified according to toxicity - carbon black - coal (hard, brown) Range: (0,06 – 17,7) mg/m3 Gravimetric method PN-Z-04507:2022-05+Ap1:2022-08
29 Workplace environment - air Concentration of harmful dust agents – respirable fraction - natural graphite - amorphous and synthetic silica - coal (hard, brown) Range: (0,05 – 6,78) mg/m3 Gravimetric method PN-Z-04508:2022-05+Ap1:2022-08
30 Workplace environment - energy expenditure Air temperature Range: (0 – 60) °C Air flow Range: (10,1 – 60,1) dm3/min Direct measurement method Procedura Badawcza PB-01 wydanie VI z dnia 20.01.2020 r.
31 Workplace environment - energy expenditure Energy expenditure (calculated)

Reference standards (18)

ISO 11338-1:2003 – Metoda C
PN-EN 12619:2013-05
PN-EN 13284-1:2018-02
PN-EN 13284-1:2018-02 PN-Z-04030-7:1994 IB/08 z dnia 20.01.2020 r.
PN-EN 13649:2005
PN-EN 14792:2017-04
PN-ISO 10396:2001
PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 3 – punkt 11
PN-Z-04008-4:1999
PN-Z-04008-7:2002 PN-Z-04008-7:2002+Az1:2004
PN-Z-04008-7:2002 PN-Z-04240-5:2006 punkt 7
PN-Z-04030-7:1994
PN-Z-04507:2022-05+Ap1:2022-08
PN-Z-04508:2022-05+Ap1:2022-08
Procedura Badawcza PB-01 wydanie VI z dnia 20.01.2020 r.
enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023
eniem punktów E.II.1 i F
nr 7