{"lab":{"_id":"69ad52a3de79e566650fb6b2","accr_number":"AB 1305","country":"PL","accr_body":"PCA","address":"ul. Piastowska 29, 47-400 Racibórz, LABORATORIUM OCHRONY ŚRODOWISKA LDS, ul. Węgierska 188, 33-300 Nowy Sącz","categories":["environment"],"city":"Nowy Sącz","imported_at":"2026-03-08T10:42:43.265Z","methods_count":31,"name":"Tokai COBEX Polska spółka z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1305.pdf"],"scope_summary":"","search_text":"tokai cobex polska spółka z o.o. ul. piastowska 29, 47-400 racibórz, laboratorium ochrony środowiska lds, ul. węgierska 188, 33-300 nowy sącz other environment food metrology","status":"active","updated_at":"2026-03-08T14:50:29.240Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:29.240Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201305,podmiot.html","parse_date":"2026-07-17T16:19:03.437Z","parse_source":"m5-mistral-qa","fields_of_testing":[{"codes":"C/36/P","pl":"Badania chemiczne i pobieranie próbek - gazy odlotowe","en":"Chemical tests and sampling - waste gases"},{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe i uciążliwe – hałas, wydatek energetyczny)","en":"Tests concerning environmental engineering (environmental and climatic) - working environment (harmful and nuisance factors noise, energy expenditure)"},{"codes":"G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko ogólne (czynniki fizyczne - hałas)","en":"Tests concerning environmental engineering (environmental and climatic) - general environment (physical factors - noise)"},{"codes":"G/36","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko ogólne – gazy odlotowe","en":"Tests concerning environmental engineering (environmental and climatic) - general environment – waste gases"},{"codes":"N/33/P, N/36/P","pl":"Badania właściwości fizycznych i pobieranie próbek – powietrze, gazy odlotowe","en":"Tests of physical properties and sampling of air, waste gases"},{"codes":"P/33, P/36","pl":"Pobieranie próbek powietrza, gazów odlotowych","en":"Sampling of air, waste gases"}],"issue":{"no":"20","date":"29.01.2026"},"map_coord":[49.624986,20.689071],"map_geo":"nominatim-street","has_en":true,"category_counts":{"environment":19,"other":12},"category_scores":{"environment":11.65,"other":4.65},"has_zh":true},"methods":[{"_id":"6a5a55f79af9f73f382520e8","lab_id":"69ad52a3de79e566650fb6b2","country":"PL","accr_number":"AB 1305","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa Metoda spiętrzania","methodology_en":"Gas volume flow rate for dynamic pressures > 10 Pa Pitot tube method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa Metoda spiętrzania","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa Metoda spiętrzania PN-Z-04030-7:1994 Gazy odlotowe Strumien objetosci gazu dla cisnien dynamicznych > 10 Pa Metoda spietrzania PN-Z-04030-7:1994","categories":["other"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Gas volume flow rate for dynamic pressures > 10 Pa Pitot tube method PN-Z-04030-7:1994","search_zh":"废气 PN-Z-04030-7:1994","test_object_zh":"废气"},{"_id":"6a5a55f79af9f73f382520e9","lab_id":"69ad52a3de79e566650fb6b2","country":"PL","accr_number":"AB 1305","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia pyłu","methodology_en":"Sampling for determination of dust concentration","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia pyłu","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia pyłu Gazy odlotowe Pobieranie probek do oznaczania stezenia pylu","categories":["other"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Sampling for determination of dust concentration","search_zh":"废气 粉尘浓度测定采样","test_object_zh":"废气","methodology_zh":"粉尘浓度测定采样"},{"_id":"6a5a55f79af9f73f382520ea","lab_id":"69ad52a3de79e566650fb6b2","country":"PL","accr_number":"AB 1305","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie pyłu Zakres: (0,001 – 100) g/m3 Metoda grawimetryczna","methodology_en":"Dust concentration Range: (0,001 – 100) g/m3 Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pyłu Zakres: (0,001 – 100) g/m3 Metoda grawimetryczna","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie pyłu Zakres: (0,001 – 100) g/m3 Metoda grawimetryczna Gazy odlotowe Stezenie pylu Zakres: (0,001 – 100) g/m3 Metoda grawimetryczna","categories":["other"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Dust concentration Range: (0,001 – 100) g/m3 Gravimetric method","search_zh":"废气 粉尘浓度 范围：(0,001 – 100) g/m3 重量法","test_object_zh":"废气","methodology_zh":"粉尘浓度 范围：(0,001 – 100) g/m3 重量法"},{"_id":"6a5a55f79af9f73f382520eb","lab_id":"69ad52a3de79e566650fb6b2","country":"PL","accr_number":"AB 1305","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja pyłu (z obliczeń)","methodology_en":"Dust emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja pyłu (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja pyłu (z obliczeń) Gazy odlotowe Emisja pylu (z obliczen)","categories":["environment"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Dust emission (calculated)","search_zh":"废气 粉尘排放量（计算值）","test_object_zh":"废气","methodology_zh":"粉尘排放量（计算值）"},{"_id":"6a5a55f79af9f73f382520ec","lab_id":"69ad52a3de79e566650fb6b2","country":"PL","accr_number":"AB 1305","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia pyłu","methodology_en":"Sampling for determination of dust concentration","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia pyłu","reference":"PN-EN 13284-1:2018-02","norm_bases":["PN-EN 13284-1:2018-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia pyłu PN-EN 13284-1:2018-02 Gazy odlotowe Pobieranie probek do oznaczania stezenia pylu PN-EN 13284-1:2018-02","categories":["other"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Sampling for determination of dust concentration PN-EN 13284-1:2018-02","search_zh":"废气 粉尘浓度测定采样 PN-EN 13284-1:2018-02","test_object_zh":"废气","methodology_zh":"粉尘浓度测定采样"},{"_id":"6a5a55f79af9f73f382520ed","lab_id":"69ad52a3de79e566650fb6b2","country":"PL","accr_number":"AB 1305","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie pyłu Zakres: (0,001 – 0,05) g/m3 Metoda grawimetryczna","methodology_en":"Dust concentration Range: (0,001 – 0,05) g/m3 Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pyłu Zakres: (0,001 – 0,05) g/m3 Metoda grawimetryczna","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie pyłu Zakres: (0,001 – 0,05) g/m3 Metoda grawimetryczna Gazy odlotowe Stezenie pylu Zakres: (0,001 – 0,05) g/m3 Metoda grawimetryczna","categories":["other"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Dust concentration Range: (0,001 – 0,05) g/m3 Gravimetric method","search_zh":"废气","test_object_zh":"废气"},{"_id":"6a5a55f79af9f73f382520ee","lab_id":"69ad52a3de79e566650fb6b2","country":"PL","accr_number":"AB 1305","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja pyłu (z obliczeń)","methodology_en":"Dust emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja pyłu (z obliczeń)","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja pyłu (z obliczeń) PN-ISO 10396:2001 Gazy odlotowe Emisja pylu (z obliczen) PN-ISO 10396:2001","categories":["environment"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Dust emission (calculated) PN-ISO 10396:2001","search_zh":"废气 粉尘排放量（计算值） PN-ISO 10396:2001","test_object_zh":"废气","methodology_zh":"粉尘排放量（计算值）"},{"_id":"6a5a55f79af9f73f382520ef","lab_id":"69ad52a3de79e566650fb6b2","country":"PL","accr_number":"AB 1305","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie tlenku węgla, dwutlenku węgla, dwutlenku siarki, tlenku azotu, tlenków azotu, tlenu Zakres: - CO (5,0 – 1000) mg/m3 - CO (0,1 – 15) % 2 - SO (10 – 450) mg/m3 2 Metoda niedyspersyjnej absorpcji w podczerwieni (NDIR) - NO (2,0 – 180) mg/m3 - NO (3,0 – 280) mg/m3 x Metoda chemiluminescencyjna (CLD) - O (0,5 – 21) % 2 Metoda paramagnetyczna (PMD)","methodology_en":"Concentration of carbon monoxide, carbon dioxide, sulphur dioxide, nitrogen monoxide, nitrogen oxides, oxygen Range: - CO (5,0 – 1000) mg/m3 - CO (0,1 – 15) % 2 - SO (10 – 450) mg/m3 2 Non-dispersive infrared absorption method (NDIR) - NO (2,0 – 180) mg/m3 - NO (3,0 – 280) mg/m3 x Chemiluminescence method (CLD) - O (0,5 – 21) % 2 Paramagnetic method (PMD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie tlenku węgla, dwutlenku węgla, dwutlenku siarki, tlenku azotu, tlenków azotu, tlenu Zakres: - CO (5,0 – 1000) mg/m3 - CO (0,1 – 15) % 2 - SO (10 – 450) mg/m3 2 Metoda niedyspersyjnej absorpcji w podczerwieni (NDIR) - NO (2,0 – 180) mg/m3 - NO (3,0 – 280) mg/m3 x Metoda chemiluminescencyjna (CLD) - O (0,5 – 21) % 2 Metoda paramagnetyczna (PMD)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie tlenku węgla, dwutlenku węgla, dwutlenku siarki, tlenku azotu, tlenków azotu, tlenu Zakres: - CO (5,0 – 1000) mg/m3 - CO (0,1 – 15) % 2 - SO (10 – 450) mg/m3 2 Metoda niedyspersyjnej absorpcji w podczerwieni (NDIR) - NO (2,0 – 180) mg/m3 - NO (3,0 – 280) mg/m3 x Metoda chemiluminescencyjna (CLD) - O (0,5 – 21) % 2 Metoda paramagnetyczna (PMD) Gazy odlotowe Stezenie tlenku wegla, dwutlenku wegla, dwutlenku siarki, tlenku azotu, tlenkow azotu, tlenu Zakres: - CO (5,0 – 1000) mg/m3 - CO (0,1 – 15) % 2 - SO (10 – 450) mg/m3 2 Metoda niedyspersyjnej absorpcji w podczerwieni (NDIR) - NO (2,0 – 180) mg/m3 - NO (3,0 – 280) mg/m3 x Metoda chemiluminescencyjna (CLD) - O (0,5 – 21) % 2 Metoda paramagnetyczna (PMD)","categories":["other"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Concentration of carbon monoxide, carbon dioxide, sulphur dioxide, nitrogen monoxide, nitrogen oxides, oxygen Range: - CO (5,0 – 1000) mg/m3 - CO (0,1 – 15) % 2 - SO (10 – 450) mg/m3 2 Non-dispersive infrared absorption method (NDIR) - NO (2,0 – 180) mg/m3 - NO (3,0 – 280) mg/m3 x Chemiluminescence method (CLD) - O (0,5 – 21) % 2 Paramagnetic method (PMD)","search_zh":"废气","test_object_zh":"废气"},{"_id":"6a5a55f79af9f73f382520f0","lab_id":"69ad52a3de79e566650fb6b2","country":"PL","accr_number":"AB 1305","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja CO, CO , SO , NO, NO 2 2 x (NO w przeliczeniu na NO ) x 2 (z obliczeń)","methodology_en":"Emission of CO, CO , SO , NO, NO 2 2 x (NO calculated as NO ) x 2 (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja CO, CO , SO , NO, NO 2 2 x (NO w przeliczeniu na NO ) x 2 (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja CO, CO , SO , NO, NO 2 2 x (NO w przeliczeniu na NO ) x 2 (z obliczeń) Gazy odlotowe Emisja CO, CO , SO , NO, NO 2 2 x (NO w przeliczeniu na NO ) x 2 (z obliczen)","categories":["environment"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Emission of CO, CO , SO , NO, NO 2 2 x (NO calculated as NO ) x 2 (calculated)","search_zh":"废气","test_object_zh":"废气"},{"_id":"6a5a55f79af9f73f382520f1","lab_id":"69ad52a3de79e566650fb6b2","country":"PL","accr_number":"AB 1305","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie tlenku azotu, tlenków azotu Zakres: - NO (2,0 – 180) mg/m3 - NO (3,0 – 280) mg/m3 x Metoda chemiluminescencyjna (CLD)","methodology_en":"Concentration of nitrogen monoxide, nitrogen oxides Range: - NO (2,0 – 180) mg/m3 - NO (3,0 – 280) mg/m3 x Chemiluminescence method (CLD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie tlenku azotu, tlenków azotu Zakres: - NO (2,0 – 180) mg/m3 - NO (3,0 – 280) mg/m3 x Metoda chemiluminescencyjna (CLD)","reference":"PN-EN 14792:2017-04","norm_bases":["PN-EN 14792:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie tlenku azotu, tlenków azotu Zakres: - NO (2,0 – 180) mg/m3 - NO (3,0 – 280) mg/m3 x Metoda chemiluminescencyjna (CLD) PN-EN 14792:2017-04 Gazy odlotowe Stezenie tlenku azotu, tlenkow azotu Zakres: - NO (2,0 – 180) mg/m3 - NO (3,0 – 280) mg/m3 x Metoda chemiluminescencyjna (CLD) PN-EN 14792:2017-04","categories":["other"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Concentration of nitrogen monoxide, nitrogen oxides Range: - NO (2,0 – 180) mg/m3 - NO (3,0 – 280) mg/m3 x Chemiluminescence method (CLD) PN-EN 14792:2017-04","search_zh":"废气 PN-EN 14792:2017-04","test_object_zh":"废气"},{"_id":"6a5a55f79af9f73f382520f2","lab_id":"69ad52a3de79e566650fb6b2","country":"PL","accr_number":"AB 1305","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja NO, NO (NO w przeliczeniu x x na NO ) 2 (z obliczeń)","methodology_en":"Emission of NO, NO (NO calculated x x as NO ) 2 (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja NO, NO (NO w przeliczeniu x x na NO ) 2 (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja NO, NO (NO w przeliczeniu x x na NO ) 2 (z obliczeń) Gazy odlotowe Emisja NO, NO (NO w przeliczeniu x x na NO ) 2 (z obliczen)","categories":["environment"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Emission of NO, NO (NO calculated x x as NO ) 2 (calculated)","search_zh":"废气","test_object_zh":"废气"},{"_id":"6a5a55f79af9f73f382520f3","lab_id":"69ad52a3de79e566650fb6b2","country":"PL","accr_number":"AB 1305","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężeń związków organicznych Metoda aspiracyjna z zastosowaniem węgla aktywnego, żelu krzemionkowego, roztworów pochłaniających","methodology_en":"Sampling for determination of the concentrations of organic compounds Aspiration method using activated carbon, silica gel, absorbing solutions","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężeń związków organicznych Metoda aspiracyjna z zastosowaniem węgla aktywnego, żelu krzemionkowego, roztworów pochłaniających","reference":"PN-Z-04008-4:1999","norm_bases":["PN-Z-04008-4:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężeń związków organicznych Metoda aspiracyjna z zastosowaniem węgla aktywnego, żelu krzemionkowego, roztworów pochłaniających PN-Z-04008-4:1999 Gazy odlotowe Pobieranie probek do oznaczania stezen zwiazkow organicznych Metoda aspiracyjna z zastosowaniem wegla aktywnego, zelu krzemionkowego, roztworow pochlaniajacych PN-Z-04008-4:1999","categories":["other"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Sampling for determination of the concentrations of organic compounds Aspiration method using activated carbon, silica gel, absorbing solutions PN-Z-04008-4:1999","search_zh":"废气 PN-Z-04008-4:1999","test_object_zh":"废气"},{"_id":"6a5a55f79af9f73f382520f4","lab_id":"69ad52a3de79e566650fb6b2","country":"PL","accr_number":"AB 1305","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja związków organicznych (z obliczeń)","methodology_en":"Emission of organic compounds (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja związków organicznych (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja związków organicznych (z obliczeń) Gazy odlotowe Emisja zwiazkow organicznych (z obliczen)","categories":["environment"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Emission of organic compounds (calculated)","search_zh":"废气 有机化合物排放量（计算值）","test_object_zh":"废气","methodology_zh":"有机化合物排放量（计算值）"},{"_id":"6a5a55f79af9f73f382520f5","lab_id":"69ad52a3de79e566650fb6b2","country":"PL","accr_number":"AB 1305","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny Zakres: (4,0 – 800) mg/m3 Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)","methodology_en":"Concentration of organic substances in gaseous and vapour form expressed as total gaseous organic carbon Range: (4,0 – 800) mg/m3 Continuous flame ionisation detection method (FID)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny Zakres: (4,0 – 800) mg/m3 Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID)","reference":"PN-EN 12619:2013-05","norm_bases":["PN-EN 12619:2013-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny Zakres: (4,0 – 800) mg/m3 Metoda ciągłej detekcji płomieniowo-jonizacyjnej (FID) PN-EN 12619:2013-05 Gazy odlotowe Stezenie substancji organicznych w postaci gazow i par wyrazone jako calkowity gazowy wegiel organiczny Zakres: (4,0 – 800) mg/m3 Metoda ciaglej detekcji plomieniowo-jonizacyjnej (FID) PN-EN 12619:2013-05","categories":["other"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Concentration of organic substances in gaseous and vapour form expressed as total gaseous organic carbon Range: (4,0 – 800) mg/m3 Continuous flame ionisation detection method (FID) PN-EN 12619:2013-05","search_zh":"废气 PN-EN 12619:2013-05","test_object_zh":"废气"},{"_id":"6a5a55f79af9f73f382520f6","lab_id":"69ad52a3de79e566650fb6b2","country":"PL","accr_number":"AB 1305","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny (z obliczeń)","methodology_en":"Emission of organic substances in gaseous and vapour form expressed as total gaseous organic carbon (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja substancji organicznych w postaci gazów i par wyrażone jako całkowity gazowy węgiel organiczny (z obliczeń) Gazy odlotowe Emisja substancji organicznych w postaci gazow i par wyrazone jako calkowity gazowy wegiel organiczny (z obliczen)","categories":["environment"],"row_index":14,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Emission of organic substances in gaseous and vapour form expressed as total gaseous organic carbon (calculated)","search_zh":"废气 以总气态有机碳表示的气态与蒸气态有机物排放量（计算值）","test_object_zh":"废气","methodology_zh":"以总气态有机碳表示的气态与蒸气态有机物排放量（计算值）"},{"_id":"6a5a55f79af9f73f382520f7","lab_id":"69ad52a3de79e566650fb6b2","country":"PL","accr_number":"AB 1305","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia indywidualnych gazowych związków organicznych","methodology_en":"Sampling for determination of the concentration of individual gaseous organic compounds","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia indywidualnych gazowych związków organicznych","reference":"PN-EN 13649:2005","norm_bases":["PN-EN 13649:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia indywidualnych gazowych związków organicznych PN-EN 13649:2005 Gazy odlotowe Pobieranie probek do oznaczania stezenia indywidualnych gazowych zwiazkow organicznych PN-EN 13649:2005","categories":["other"],"row_index":15,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Sampling for determination of the concentration of individual gaseous organic compounds PN-EN 13649:2005","search_zh":"废气 单项气态有机化合物浓度测定采样 PN-EN 13649:2005","test_object_zh":"废气","methodology_zh":"单项气态有机化合物浓度测定采样"},{"_id":"6a5a55f79af9f73f382520f8","lab_id":"69ad52a3de79e566650fb6b2","country":"PL","accr_number":"AB 1305","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja indywidualnych gazowych związków organicznych (z obliczeń)","methodology_en":"Emission of individual gaseous organic compounds (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja indywidualnych gazowych związków organicznych (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja indywidualnych gazowych związków organicznych (z obliczeń) Gazy odlotowe Emisja indywidualnych gazowych zwiazkow organicznych (z obliczen)","categories":["environment"],"row_index":16,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Emission of individual gaseous organic compounds (calculated)","search_zh":"废气 单项气态有机化合物排放量（计算值）","test_object_zh":"废气","methodology_zh":"单项气态有机化合物排放量（计算值）"},{"_id":"6a5a55f79af9f73f382520f9","lab_id":"69ad52a3de79e566650fb6b2","country":"PL","accr_number":"AB 1305","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania masowego stężenia WWA Metoda filtracyjno-kondensacyjno- adsorpcyjna","methodology_en":"Sampling for determination of the mass concentration of PAH Filtration-condensation-adsorption method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania masowego stężenia WWA Metoda filtracyjno-kondensacyjno- adsorpcyjna","reference":"ISO 11338-1:2003 – Metoda C","norm_bases":["ISO 11338-1:2003 – Metoda C"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania masowego stężenia WWA Metoda filtracyjno-kondensacyjno- adsorpcyjna ISO 11338-1:2003 – Metoda C Gazy odlotowe Pobieranie probek do oznaczania masowego stezenia WWA Metoda filtracyjno-kondensacyjno- adsorpcyjna ISO 11338-1:2003 – Metoda C","categories":["other"],"row_index":17,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Sampling for determination of the mass concentration of PAH Filtration-condensation-adsorption method ISO 11338-1:2003 – Metoda C","search_zh":"废气 ISO 11338-1:2003 – Metoda C","test_object_zh":"废气"},{"_id":"6a5a55f79af9f73f382520fa","lab_id":"69ad52a3de79e566650fb6b2","country":"PL","accr_number":"AB 1305","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja WWA (z obliczeń)","methodology_en":"PAH emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja WWA (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja WWA (z obliczeń) Gazy odlotowe Emisja WWA (z obliczen)","categories":["environment"],"row_index":18,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases PAH emission (calculated)","search_zh":"废气 多环芳烃排放（由计算得出）","test_object_zh":"废气","methodology_zh":"多环芳烃排放（由计算得出）"},{"_id":"6a5a55f79af9f73f382520fb","lab_id":"69ad52a3de79e566650fb6b2","country":"PL","accr_number":"AB 1305","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia frakcji pyłu PM 2,5 i PM 10","methodology_en":"Sampling for determination of the concentration of dust fractions PM 2,5 and PM 10","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia frakcji pyłu PM 2,5 i PM 10","reference":"PN-EN 13284-1:2018-02 PN-Z-04030-7:1994 IB/08 z dnia 20.01.2020 r.","norm_bases":["PN-EN 13284-1:2018-02 PN-Z-04030-7:1994 IB/08 z dnia 20.01.2020 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia frakcji pyłu PM 2,5 i PM 10 PN-EN 13284-1:2018-02 PN-Z-04030-7:1994 IB/08 z dnia 20.01.2020 r. Gazy odlotowe Pobieranie probek do oznaczania stezenia frakcji pylu PM 2,5 i PM 10 PN-EN 13284-1:2018-02 PN-Z-04030-7:1994 IB/08 z dnia 20.01.2020 r.","categories":["other"],"row_index":19,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Sampling for determination of the concentration of dust fractions PM 2,5 and PM 10 PN-EN 13284-1:2018-02 PN-Z-04030-7:1994 IB/08 z dnia 20.01.2020 r.","search_zh":"废气 PN-EN 13284-1:2018-02 PN-Z-04030-7:1994 IB/08 z dnia 20.01.2020 r.","test_object_zh":"废气"},{"_id":"6a5a55f79af9f73f382520fc","lab_id":"69ad52a3de79e566650fb6b2","country":"PL","accr_number":"AB 1305","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","test_object_en":"General environment – noise from installations, equipment and industrial plants","methodology":"Równoważny poziom dźwięku A Zakres: (23 – 130) dB Metoda pomiarowa bezpośrednia","methodology_en":"A-weighted equivalent sound level Range: (23 – 130) dB Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A Zakres: (23 – 130) dB Metoda pomiarowa bezpośrednia","reference":"nr 7 | enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 | eniem punktów E.II.1 i F","norm_bases":["nr 7","enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023","eniem punktów E.II.1 i F"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A Zakres: (23 – 130) dB Metoda pomiarowa bezpośrednia nr 7 | enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 | eniem punktów E.II.1 i F Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A Zakres: (23 – 130) dB Metoda pomiarowa bezposrednia nr 7 | enia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 | eniem punktow E.II.1 i F","categories":["environment"],"row_index":20,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound level Range: (23 – 130) dB Direct measurement method nr 7 | enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 | eniem punktów E.II.1 i F","search_zh":"一般环境 – 来自设施、设备与工业企业的噪声 nr 7 | enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 | eniem punktów E.II.1 i F","test_object_zh":"一般环境 – 来自设施、设备与工业企业的噪声"},{"_id":"6a5a55f79af9f73f382520fd","lab_id":"69ad52a3de79e566650fb6b2","country":"PL","accr_number":"AB 1305","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","test_object_en":"General environment – noise from installations, equipment and industrial plants","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami L i L AeqD AeqN (z obliczeń)","methodology_en":"A-weighted equivalent sound level for reference time T expressed as L and L AeqD AeqN indices (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami L i L AeqD AeqN (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami L i L AeqD AeqN (z obliczeń) Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami L i L AeqD AeqN (z obliczen)","categories":["environment"],"row_index":21,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound level for reference time T expressed as L and L AeqD AeqN indices (calculated)","search_zh":"一般环境 – 来自设施、设备与工业企业的噪声 参考时间 T 的 A 计权等效声级，以 L 与 L AeqD AeqN 指标表示（计算值）","test_object_zh":"一般环境 – 来自设施、设备与工业企业的噪声","methodology_zh":"参考时间 T 的 A 计权等效声级，以 L 与 L AeqD AeqN 指标表示（计算值）"},{"_id":"6a5a55f79af9f73f382520fe","lab_id":"69ad52a3de79e566650fb6b2","country":"PL","accr_number":"AB 1305","accr_body":"PCA","test_object":"Środowisko pracy - hałas","test_object_en":"Workplace environment - noise","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Zakres: (30 – 136) dB Szczytowy poziom dźwięku C Zakres: (30 – 136) dB Metoda pomiarowa bezpośrednia","methodology_en":"A-weighted equivalent sound level A-weighted maximum sound level Range: (30 – 136) dB C-weighted peak sound level Range: (30 – 136) dB Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Zakres: (30 – 136) dB Szczytowy poziom dźwięku C Zakres: (30 – 136) dB Metoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 3 – punkt 11","norm_bases":["PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 3 – punkt 11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Zakres: (30 – 136) dB Szczytowy poziom dźwięku C Zakres: (30 – 136) dB Metoda pomiarowa bezpośrednia PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 3 – punkt 11 Srodowisko pracy - halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A Zakres: (30 – 136) dB Szczytowy poziom dzwieku C Zakres: (30 – 136) dB Metoda pomiarowa bezposrednia PN-N-01307:1994 PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 3 – punkt 11","categories":["environment"],"row_index":22,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - noise A-weighted equivalent sound level A-weighted maximum sound level Range: (30 – 136) dB C-weighted peak sound level Range: (30 – 136) dB Direct measurement method PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 3 – punkt 11","search_zh":"工作场所环境 — 噪声 PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 3 – punkt 11","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a5a55f79af9f73f382520ff","lab_id":"69ad52a3de79e566650fb6b2","country":"PL","accr_number":"AB 1305","accr_body":"PCA","test_object":"Środowisko pracy - hałas","test_object_en":"Workplace environment - noise","methodology":"Poziom ekspozycji na hałas odniesiony do: - 8-godz. dobowego wymiaru czasu pracy - przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","methodology_en":"Noise exposure level referred to: - the 8-hour daily working time - the average weekly working time (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom ekspozycji na hałas odniesiony do: - 8-godz. dobowego wymiaru czasu pracy - przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - hałas Poziom ekspozycji na hałas odniesiony do: - 8-godz. dobowego wymiaru czasu pracy - przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) Srodowisko pracy - halas Poziom ekspozycji na halas odniesiony do: - 8-godz. dobowego wymiaru czasu pracy - przecietnego tygodniowego wymiaru czasu pracy (z obliczen)","categories":["environment"],"row_index":23,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - noise Noise exposure level referred to: - the 8-hour daily working time - the average weekly working time (calculated)","search_zh":"工作场所环境 — 噪声 噪声暴露级，参照： — 8 小时日工作时间 — 平均每周工作时间（计算值）","test_object_zh":"工作场所环境 — 噪声","methodology_zh":"噪声暴露级，参照： — 8 小时日工作时间 — 平均每周工作时间（计算值）"},{"_id":"6a5a55f79af9f73f38252100","lab_id":"69ad52a3de79e566650fb6b2","country":"PL","accr_number":"AB 1305","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","test_object_en":"Workplace environment - air","methodology":"Pobieranie próbek do oceny narażenia zawodowego na: - pyły przemysłowe – frakcja wdychalna – frakcja respirabilna - substancje nieorganiczne – frakcja respirabilna Metoda dozymetrii indywidualnej","methodology_en":"Sampling for occupational exposure assessment to: - industrial dusts – inhalable fraction – respirable fraction - inorganic substances – respirable fraction Personal dosimetry method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na: - pyły przemysłowe – frakcja wdychalna – frakcja respirabilna - substancje nieorganiczne – frakcja respirabilna Metoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002 PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002 PN-Z-04008-7:2002+Az1:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - powietrze Pobieranie próbek do oceny narażenia zawodowego na: - pyły przemysłowe – frakcja wdychalna – frakcja respirabilna - substancje nieorganiczne – frakcja respirabilna Metoda dozymetrii indywidualnej PN-Z-04008-7:2002 PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy - powietrze Pobieranie probek do oceny narazenia zawodowego na: - pyly przemyslowe – frakcja wdychalna – frakcja respirabilna - substancje nieorganiczne – frakcja respirabilna Metoda dozymetrii indywidualnej PN-Z-04008-7:2002 PN-Z-04008-7:2002+Az1:2004","categories":["environment"],"row_index":24,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - air Sampling for occupational exposure assessment to: - industrial dusts – inhalable fraction – respirable fraction - inorganic substances – respirable fraction Personal dosimetry method PN-Z-04008-7:2002 PN-Z-04008-7:2002+Az1:2004","search_zh":"工作场所环境 — 空气 PN-Z-04008-7:2002 PN-Z-04008-7:2002+Az1:2004","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a5a55f79af9f73f38252101","lab_id":"69ad52a3de79e566650fb6b2","country":"PL","accr_number":"AB 1305","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","test_object_en":"Workplace environment - air","methodology":"Wskaźnik narażenia (z obliczeń)","methodology_en":"Exposure index (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - powietrze Wskaźnik narażenia (z obliczeń) Srodowisko pracy - powietrze Wskaznik narazenia (z obliczen)","categories":["environment"],"row_index":25,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - air Exposure index (calculated)","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出）","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a5a55f79af9f73f38252102","lab_id":"69ad52a3de79e566650fb6b2","country":"PL","accr_number":"AB 1305","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","test_object_en":"Workplace environment - air","methodology":"Pobieranie próbek do oceny narażenia zawodowego i oznaczania wielopierścieniowych węglowodorów aromatycznych Metoda dozymetrii indywidualnej","methodology_en":"Sampling for occupational exposure assessment and determination of polycyclic aromatic hydrocarbons Personal dosimetry method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego i oznaczania wielopierścieniowych węglowodorów aromatycznych Metoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002 PN-Z-04240-5:2006 punkt 7","norm_bases":["PN-Z-04008-7:2002 PN-Z-04240-5:2006 punkt 7"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - powietrze Pobieranie próbek do oceny narażenia zawodowego i oznaczania wielopierścieniowych węglowodorów aromatycznych Metoda dozymetrii indywidualnej PN-Z-04008-7:2002 PN-Z-04240-5:2006 punkt 7 Srodowisko pracy - powietrze Pobieranie probek do oceny narazenia zawodowego i oznaczania wielopierscieniowych weglowodorow aromatycznych Metoda dozymetrii indywidualnej PN-Z-04008-7:2002 PN-Z-04240-5:2006 punkt 7","categories":["environment"],"row_index":26,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - air Sampling for occupational exposure assessment and determination of polycyclic aromatic hydrocarbons Personal dosimetry method PN-Z-04008-7:2002 PN-Z-04240-5:2006 punkt 7","search_zh":"工作场所环境 — 空气 PN-Z-04008-7:2002 PN-Z-04240-5:2006 punkt 7","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a5a55f79af9f73f38252103","lab_id":"69ad52a3de79e566650fb6b2","country":"PL","accr_number":"AB 1305","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","test_object_en":"Workplace environment - air","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna - grafit naturalny - grafit syntetyczny - krzemionka bezpostaciowa i syntetyczna - pyły drewna - pyły niesklasyfikowane ze względu na toksyczność - sadza techniczna - węgiel (kamienny, brunatny) Zakres: (0,06 – 17,7) mg/m3 Metoda grawimetryczna","methodology_en":"Concentration of harmful dust agents – inhalable fraction - natural graphite - synthetic graphite - amorphous and synthetic silica - wood dust - dusts not classified according to toxicity - carbon black - coal (hard, brown) Range: (0,06 – 17,7) mg/m3 Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna - grafit naturalny - grafit syntetyczny - krzemionka bezpostaciowa i syntetyczna - pyły drewna - pyły niesklasyfikowane ze względu na toksyczność - sadza techniczna - węgiel (kamienny, brunatny) Zakres: (0,06 – 17,7) mg/m3 Metoda grawimetryczna","reference":"PN-Z-04507:2022-05+Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05+Ap1:2022-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna - grafit naturalny - grafit syntetyczny - krzemionka bezpostaciowa i syntetyczna - pyły drewna - pyły niesklasyfikowane ze względu na toksyczność - sadza techniczna - węgiel (kamienny, brunatny) Zakres: (0,06 – 17,7) mg/m3 Metoda grawimetryczna PN-Z-04507:2022-05+Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia – frakcja wdychalna - grafit naturalny - grafit syntetyczny - krzemionka bezpostaciowa i syntetyczna - pyly drewna - pyly niesklasyfikowane ze wzgledu na toksycznosc - sadza techniczna - wegiel (kamienny, brunatny) Zakres: (0,06 – 17,7) mg/m3 Metoda grawimetryczna PN-Z-04507:2022-05+Ap1:2022-08","categories":["environment"],"row_index":27,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - air Concentration of harmful dust agents – inhalable fraction - natural graphite - synthetic graphite - amorphous and synthetic silica - wood dust - dusts not classified according to toxicity - carbon black - coal (hard, brown) Range: (0,06 – 17,7) mg/m3 Gravimetric method PN-Z-04507:2022-05+Ap1:2022-08","search_zh":"工作场所环境 — 空气 PN-Z-04507:2022-05+Ap1:2022-08","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a5a55f79af9f73f38252104","lab_id":"69ad52a3de79e566650fb6b2","country":"PL","accr_number":"AB 1305","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","test_object_en":"Workplace environment - air","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna - grafit naturalny - krzemionka bezpostaciowa i syntetyczna - węgiel (kamienny, brunatny) Zakres: (0,05 – 6,78) mg/m3 Metoda grawimetryczna","methodology_en":"Concentration of harmful dust agents – respirable fraction - natural graphite - amorphous and synthetic silica - coal (hard, brown) Range: (0,05 – 6,78) mg/m3 Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna - grafit naturalny - krzemionka bezpostaciowa i syntetyczna - węgiel (kamienny, brunatny) Zakres: (0,05 – 6,78) mg/m3 Metoda grawimetryczna","reference":"PN-Z-04508:2022-05+Ap1:2022-08","norm_bases":["PN-Z-04508:2022-05+Ap1:2022-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna - grafit naturalny - krzemionka bezpostaciowa i syntetyczna - węgiel (kamienny, brunatny) Zakres: (0,05 – 6,78) mg/m3 Metoda grawimetryczna PN-Z-04508:2022-05+Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia – frakcja respirabilna - grafit naturalny - krzemionka bezpostaciowa i syntetyczna - wegiel (kamienny, brunatny) Zakres: (0,05 – 6,78) mg/m3 Metoda grawimetryczna PN-Z-04508:2022-05+Ap1:2022-08","categories":["environment"],"row_index":28,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - air Concentration of harmful dust agents – respirable fraction - natural graphite - amorphous and synthetic silica - coal (hard, brown) Range: (0,05 – 6,78) mg/m3 Gravimetric method PN-Z-04508:2022-05+Ap1:2022-08","search_zh":"工作场所环境 — 空气 PN-Z-04508:2022-05+Ap1:2022-08","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a5a55f79af9f73f38252105","lab_id":"69ad52a3de79e566650fb6b2","country":"PL","accr_number":"AB 1305","accr_body":"PCA","test_object":"Środowisko pracy - wydatek energetyczny","test_object_en":"Workplace environment - energy expenditure","methodology":"Temperatura powietrza Zakres: (0 – 60) °C Przepływ powietrza Zakres: (10,1 – 60,1) dm3/min Metoda pomiarowa bezpośrednia","methodology_en":"Air temperature Range: (0 – 60) °C Air flow Range: (10,1 – 60,1) dm3/min Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Temperatura powietrza Zakres: (0 – 60) °C Przepływ powietrza Zakres: (10,1 – 60,1) dm3/min Metoda pomiarowa bezpośrednia","reference":"Procedura Badawcza PB-01 wydanie VI z dnia 20.01.2020 r.","norm_bases":["Procedura Badawcza PB-01 wydanie VI z dnia 20.01.2020 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - wydatek energetyczny Temperatura powietrza Zakres: (0 – 60) °C Przepływ powietrza Zakres: (10,1 – 60,1) dm3/min Metoda pomiarowa bezpośrednia Procedura Badawcza PB-01 wydanie VI z dnia 20.01.2020 r. Srodowisko pracy - wydatek energetyczny Temperatura powietrza Zakres: (0 – 60) °C Przeplyw powietrza Zakres: (10,1 – 60,1) dm3/min Metoda pomiarowa bezposrednia Procedura Badawcza PB-01 wydanie VI z dnia 20.01.2020 r.","categories":["environment"],"row_index":29,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - energy expenditure Air temperature Range: (0 – 60) °C Air flow Range: (10,1 – 60,1) dm3/min Direct measurement method Procedura Badawcza PB-01 wydanie VI z dnia 20.01.2020 r.","search_zh":"工作场所环境 — 能量消耗 Procedura Badawcza PB-01 wydanie VI z dnia 20.01.2020 r.","test_object_zh":"工作场所环境 — 能量消耗"},{"_id":"6a5a55f79af9f73f38252106","lab_id":"69ad52a3de79e566650fb6b2","country":"PL","accr_number":"AB 1305","accr_body":"PCA","test_object":"Środowisko pracy - wydatek energetyczny","test_object_en":"Workplace environment - energy expenditure","methodology":"Wydatek energetyczny (z obliczeń)","methodology_en":"Energy expenditure (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wydatek energetyczny (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - wydatek energetyczny Wydatek energetyczny (z obliczeń) Srodowisko pracy - wydatek energetyczny Wydatek energetyczny (z obliczen)","categories":["environment"],"row_index":30,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - energy expenditure Energy expenditure (calculated)","methodology_zh":"能量消耗（计算值）","search_zh":"工作场所环境 — 能量消耗 能量消耗（计算值）","test_object_zh":"工作场所环境 — 能量消耗"}],"has_pdf":true}