🇵🇱 ZAKŁAD WODOCIĄGÓW I KANALIZACJI Sp. z o.o. PL
Water & wastewaterMicrobiology
ZAKŁAD WODOCIĄGÓW I KANALIZACJI Sp. z o.o. is a laboratory accredited by PCA under number AB 1303 (Andrychów, Poland). Its accreditation scope covers 44 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water Water intended for human consumption, Wastewater, Water, Water intended for human consumption.
At a glance
- Accreditation number: PCA AB 1303
- Methods in scope: 44
- Types of test objects: 4
- City: Andrychów, Poland
- Accreditation number
- AB 1303
- Accreditation body
- PCA
- Address
- LABORATORIUM BADANIA WODY I ŚCIEKÓW, ul. Batorego 68, 34-120 Andrychów
- City
- Andrychów, Poland
What this laboratory tests (4)
- Water Water intended for human consumption — 20 methods
- Wastewater — 17 methods
- Water — 5 methods
- Water intended for human consumption — 2 methods
Accreditation scope — test methods (44)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Water intended for human consumption | Sampling for chemical and physical testing | PN-ISO 5667-5:2017-10 | ||
| 2 | Water intended for human consumption | Sampling for microbiological testing | PN-EN ISO 19458:2007 | ||
| 3 | Water | Sampling for chemical and physical testing | PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.5 | ||
| 4 | Water | Sampling for microbiological testing | PN-EN ISO 19458:2007 | ||
| 5 | Water Water intended for human consumption | pH Range: 4,0 – 10,0 Potentiometric method | PN-EN ISO 10523:2012 | ||
| 6 | Water Water intended for human consumption | Electrical conductivity Range: (50 – 2500) μS/cm Conductometric method | PN-EN 27888:1999 | ||
| 7 | Water Water intended for human consumption | Turbidity Range: (0,20 – 100) NTU Nephelometric method | PN-EN ISO 7027-1:2016-09 | ||
| 8 | Water Water intended for human consumption | Colour Range: (5 – 50) mg/l Pt Visual method | PN-EN ISO 7887:2012 Metoda D +Ap1:2015-06 | ||
| 9 | Water Water intended for human consumption | Total suspended solids (TSS) Range: (2,0 – 500) mg/l Gravimetric method | PN-EN 872:2007+Ap1:2007 | ||
| 10 | Water Water intended for human consumption | Ammonium ion concentration Range: (0,050 – 1,00) mg/l Spectrophotometric method | PN-ISO 7150-1:2002 | ||
| 11 | Water Water intended for human consumption | Nitrite concentration Range: (0,010 – 0,800) mg/l Spectrophotometric method | PN-EN 26777:1999 | ||
| 12 | Water Water intended for human consumption | Nitrate concentration Range: (0,9 – 50,0) mg/l Spectrophotometric method | PN-82/C-04576/08 | ||
| 13 | Water Water intended for human consumption | Total calcium and magnesium content (total hardness) Range: (10 – 600) mg/l CaCO3 Titrimetric method | PN-ISO 6059:1999 | ||
| 14 | Water Water intended for human consumption | Total iron concentration Range: (20,0 – 1400) µg/l Spectrophotometric method | PB/06/W wydanie 2 z dn. 01.06.2010 na podstawie metody Hach Nr 8147 | ||
| 15 | Water Water intended for human consumption | Manganese concentration Range: (20,0 – 700) µg/l Spectrophotometric method | PB/11/W wydanie 2 z dn. 01.06.2010 na podstawie metody Hach Nr 8149 | ||
| 16 | Water Water intended for human consumption | Chloride concentration Range: (5,00 – 500) mg/l Titrimetric method | PN-ISO 9297:1994 | ||
| 17 | Water | Biochemical oxygen demand - BOD5 Range: (0,50 - 6,0) mg/l O2 Electrochemical method | PN-EN 1899-2:2002 | ||
| 18 | Water | Chemical oxygen demand - COD-Cr Range: (10,0 - 150) mg/l O2 Spectrophotometric method | PN-ISO 15705:2005 | ||
| 19 | Water Water intended for human consumption | Total count of microorganisms at 22 °C Plate method, pour plate | PN-EN ISO 6222:2004 | ||
| 20 | Water Water intended for human consumption | Total count of microorganisms at 36 °C Plate method, pour plate | |||
| 21 | Water Water intended for human consumption | Coliform bacteria count Membrane filtration method | PN-EN ISO 9308-1:2014-12+A1:2017-04 | ||
| 22 | Water Water intended for human consumption | Escherichia coli count Membrane filtration method | |||
| 23 | Water Water intended for human consumption | Most probable number of coliform bacteria MPN method | PN-EN ISO 9308-2:2014-06 | ||
| 24 | Water Water intended for human consumption | Most probable number of Escherichia coli MPN method | |||
| 25 | Water Water intended for human consumption | Intestinal enterococci count Membrane filtration method | PN-EN ISO 7899-2:2004 | ||
| 26 | Water Water intended for human consumption | Clostridium perfringens count including spores Membrane filtration method | PN-EN ISO 14189:2016-10 | ||
| 27 | Wastewater | Sampling for chemical and physical testing Manual method, automatic method Temperature of the wastewater sample taken Range: (1,0 – 35) °C | PN-ISO 5667-10:2021-11 PN-77/C-04584 | ||
| 28 | Wastewater | pH Range: 4,0 – 10,0 Potentiometric method | PN-EN ISO 10523:2012 | ||
| 29 | Wastewater | Electrical conductivity Range: (147 – 2500) μS/cm Conductometric method | PN-EN 27888:1999 | ||
| 30 | Wastewater | Ammonium nitrogen concentration Range: (0,050 – 10,0) mg/l Spectrophotometric method | PN-ISO 7150-1:2002 | ||
| 31 | Wastewater | Ammonium nitrogen concentration Range: (2,00 – 1000) mg/l Titrimetric method | PN-ISO 5664:2002 | ||
| 32 | Wastewater | Nitrite nitrogen concentration Range: (0,010 – 10) mg/l Spectrophotometric method | PN-EN 26777:1999 | ||
| 33 | Wastewater | Nitrate nitrogen concentration Range: (0,10 – 30) mg/l Spectrophotometric method | PN-82/C-04576/08 | ||
| 34 | Wastewater | Kjeldahl nitrogen concentration Range: (1,00 – 1000) mg/l Titrimetric method | PN-EN 25663:2001 | ||
| 35 | Wastewater | Total nitrogen concentration (calculated) | PN-73/C-04576/14 | ||
| 36 | Wastewater | Chloride concentration Range: (5,00 – 5000) mg/l Titrimetric method | PN-ISO 9297:1994 | ||
| 37 | Wastewater | Biochemical oxygen demand - BOD5 Range: (3 – 3000) mg/l O2 Electrochemical method | PN-EN ISO 5815-1:2019-12 | ||
| 38 | Wastewater | Biochemical oxygen demand - BOD5 Range: (0,50 – 6,0) mg/l O2 Electrochemical method | PN-EN 1899-2:2002 | ||
| 39 | Wastewater | Chemical oxygen demand - COD-Cr Range: (10,0 – 10000) mg/l O2 Spectrophotometric method | PN-ISO 15705:2005 | ||
| 40 | Wastewater | Total phosphorus concentration Range: (0,10 – 50,0) mg/l Spectrophotometric method | PN-EN ISO 6878:2006 pkt 8 +Ap1:2010+Ap2:2010 | ||
| 41 | Wastewater | Total suspended solids (TSS) Range: (2,0 – 5000) mg/l Gravimetric method | PN-EN 872:2007+Ap1:2007 | ||
| 42 | Wastewater | Phenol index Range: (0,002 – 2,6) mg/l Spectrophotometric method | PN-ISO 6439:1994 Metoda B | ||
| 43 | Wastewater | Sulfate concentration Range: (10 – 500) mg/l Gravimetric method | PN-ISO 9280:2002 | ||
| 44 | Water | Sulphate concentration Range: (10 – 250) mg/l Gravimetric method | PN-ISO 9280:2002 | ||
Reference standards (30)
PB/06/W wydanie 2 z dn. 01.06.2010 na podstawie metody Hach Nr 8147
PB/11/W wydanie 2 z dn. 01.06.2010 na podstawie metody Hach Nr 8149
PN-73/C-04576/14
PN-82/C-04576/08
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 14189:2016-10
PN-EN ISO 19458:2007
PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.5
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006 pkt 8 +Ap1:2010+Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 Metoda D +Ap1:2015-06
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014-12+A1:2017-04
PN-EN ISO 9308-2:2014-06
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11 PN-77/C-04584
PN-ISO 5667-5:2017-10
PN-ISO 6059:1999
PN-ISO 6439:1994 Metoda B
PN-ISO 7150-1:2002
PN-ISO 9280:2002
PN-ISO 9297:1994