🇵🇱 ZAKŁAD WODOCIĄGÓW I KANALIZACJI Sp. z o.o. PL

PCA AB 1303 • Andrychów, Poland • 44 methods

Water & wastewaterMicrobiology

ZAKŁAD WODOCIĄGÓW I KANALIZACJI Sp. z o.o. is a laboratory accredited by PCA under number AB 1303 (Andrychów, Poland). Its accreditation scope covers 44 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water Water intended for human consumption, Wastewater, Water, Water intended for human consumption.

At a glance

  • Accreditation number: PCA AB 1303
  • Methods in scope: 44
  • Types of test objects: 4
  • City: Andrychów, Poland
Accreditation number
AB 1303
Accreditation body
PCA
Address
LABORATORIUM BADANIA WODY I ŚCIEKÓW, ul. Batorego 68, 34-120 Andrychów
City
Andrychów, Poland

What this laboratory tests (4)

Accreditation scope — test methods (44)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10
2 Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007
3 Water Sampling for chemical and physical testing PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.5
4 Water Sampling for microbiological testing PN-EN ISO 19458:2007
5 Water Water intended for human consumption pH Range: 4,0 – 10,0 Potentiometric method PN-EN ISO 10523:2012
6 Water Water intended for human consumption Electrical conductivity Range: (50 – 2500) μS/cm Conductometric method PN-EN 27888:1999
7 Water Water intended for human consumption Turbidity Range: (0,20 – 100) NTU Nephelometric method PN-EN ISO 7027-1:2016-09
8 Water Water intended for human consumption Colour Range: (5 – 50) mg/l Pt Visual method PN-EN ISO 7887:2012 Metoda D +Ap1:2015-06
9 Water Water intended for human consumption Total suspended solids (TSS) Range: (2,0 – 500) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007
10 Water Water intended for human consumption Ammonium ion concentration Range: (0,050 – 1,00) mg/l Spectrophotometric method PN-ISO 7150-1:2002
11 Water Water intended for human consumption Nitrite concentration Range: (0,010 – 0,800) mg/l Spectrophotometric method PN-EN 26777:1999
12 Water Water intended for human consumption Nitrate concentration Range: (0,9 – 50,0) mg/l Spectrophotometric method PN-82/C-04576/08
13 Water Water intended for human consumption Total calcium and magnesium content (total hardness) Range: (10 – 600) mg/l CaCO3 Titrimetric method PN-ISO 6059:1999
14 Water Water intended for human consumption Total iron concentration Range: (20,0 – 1400) µg/l Spectrophotometric method PB/06/W wydanie 2 z dn. 01.06.2010 na podstawie metody Hach Nr 8147
15 Water Water intended for human consumption Manganese concentration Range: (20,0 – 700) µg/l Spectrophotometric method PB/11/W wydanie 2 z dn. 01.06.2010 na podstawie metody Hach Nr 8149
16 Water Water intended for human consumption Chloride concentration Range: (5,00 – 500) mg/l Titrimetric method PN-ISO 9297:1994
17 Water Biochemical oxygen demand - BOD5 Range: (0,50 - 6,0) mg/l O2 Electrochemical method PN-EN 1899-2:2002
18 Water Chemical oxygen demand - COD-Cr Range: (10,0 - 150) mg/l O2 Spectrophotometric method PN-ISO 15705:2005
19 Water Water intended for human consumption Total count of microorganisms at 22 °C Plate method, pour plate PN-EN ISO 6222:2004
20 Water Water intended for human consumption Total count of microorganisms at 36 °C Plate method, pour plate
21 Water Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12+A1:2017-04
22 Water Water intended for human consumption Escherichia coli count Membrane filtration method
23 Water Water intended for human consumption Most probable number of coliform bacteria MPN method PN-EN ISO 9308-2:2014-06
24 Water Water intended for human consumption Most probable number of Escherichia coli MPN method
25 Water Water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
26 Water Water intended for human consumption Clostridium perfringens count including spores Membrane filtration method PN-EN ISO 14189:2016-10
27 Wastewater Sampling for chemical and physical testing Manual method, automatic method Temperature of the wastewater sample taken Range: (1,0 – 35) °C PN-ISO 5667-10:2021-11 PN-77/C-04584
28 Wastewater pH Range: 4,0 – 10,0 Potentiometric method PN-EN ISO 10523:2012
29 Wastewater Electrical conductivity Range: (147 – 2500) μS/cm Conductometric method PN-EN 27888:1999
30 Wastewater Ammonium nitrogen concentration Range: (0,050 – 10,0) mg/l Spectrophotometric method PN-ISO 7150-1:2002
31 Wastewater Ammonium nitrogen concentration Range: (2,00 – 1000) mg/l Titrimetric method PN-ISO 5664:2002
32 Wastewater Nitrite nitrogen concentration Range: (0,010 – 10) mg/l Spectrophotometric method PN-EN 26777:1999
33 Wastewater Nitrate nitrogen concentration Range: (0,10 – 30) mg/l Spectrophotometric method PN-82/C-04576/08
34 Wastewater Kjeldahl nitrogen concentration Range: (1,00 – 1000) mg/l Titrimetric method PN-EN 25663:2001
35 Wastewater Total nitrogen concentration (calculated) PN-73/C-04576/14
36 Wastewater Chloride concentration Range: (5,00 – 5000) mg/l Titrimetric method PN-ISO 9297:1994
37 Wastewater Biochemical oxygen demand - BOD5 Range: (3 – 3000) mg/l O2 Electrochemical method PN-EN ISO 5815-1:2019-12
38 Wastewater Biochemical oxygen demand - BOD5 Range: (0,50 – 6,0) mg/l O2 Electrochemical method PN-EN 1899-2:2002
39 Wastewater Chemical oxygen demand - COD-Cr Range: (10,0 – 10000) mg/l O2 Spectrophotometric method PN-ISO 15705:2005
40 Wastewater Total phosphorus concentration Range: (0,10 – 50,0) mg/l Spectrophotometric method PN-EN ISO 6878:2006 pkt 8 +Ap1:2010+Ap2:2010
41 Wastewater Total suspended solids (TSS) Range: (2,0 – 5000) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007
42 Wastewater Phenol index Range: (0,002 – 2,6) mg/l Spectrophotometric method PN-ISO 6439:1994 Metoda B
43 Wastewater Sulfate concentration Range: (10 – 500) mg/l Gravimetric method PN-ISO 9280:2002
44 Water Sulphate concentration Range: (10 – 250) mg/l Gravimetric method PN-ISO 9280:2002

Reference standards (30)

PB/06/W wydanie 2 z dn. 01.06.2010 na podstawie metody Hach Nr 8147
PB/11/W wydanie 2 z dn. 01.06.2010 na podstawie metody Hach Nr 8149
PN-73/C-04576/14
PN-82/C-04576/08
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 14189:2016-10
PN-EN ISO 19458:2007
PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.5
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006 pkt 8 +Ap1:2010+Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 Metoda D +Ap1:2015-06
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014-12+A1:2017-04
PN-EN ISO 9308-2:2014-06
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11 PN-77/C-04584
PN-ISO 5667-5:2017-10
PN-ISO 6059:1999
PN-ISO 6439:1994 Metoda B
PN-ISO 7150-1:2002
PN-ISO 9280:2002
PN-ISO 9297:1994