{"lab":{"_id":"69ad52a3de79e566650fb6b0","accr_number":"AB 1303","country":"PL","accr_body":"PCA","address":"LABORATORIUM BADANIA WODY I ŚCIEKÓW, ul. Batorego 68, 34-120 Andrychów","categories":["water","microbiology"],"city":"Andrychów","imported_at":"2026-03-08T10:42:43.265Z","methods_count":44,"name":"ZAKŁAD WODOCIĄGÓW I KANALIZACJI Sp. z o.o.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1303.pdf"],"scope_summary":"","search_text":"zakład wodociągów i kanalizacji sp. z o.o. laboratorium badania wody i ścieków, ul. batorego 68, 34-120 andrychów water microbiology pharma electronics other automotive","status":"active","updated_at":"2026-03-08T14:50:29.162Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:29.162Z","email_confidence":"high","email_mx":true,"email_source":"https://www.zwikandrychow.pl/kontakt/","parse_date":"2026-07-17T16:19:03.394Z","parse_source":"m5-mistral-qa","fields_of_testing":[{"codes":"C/28/P; C/29/P; C/30/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Chemical tests and sampling of water, drinking water, sewage"},{"codes":"K/28/P; K/29/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody, wody do spożycia przez ludzi","en":"Microbiological tests and sampling of water, drinking water"},{"codes":"N/28/P; N/29/P; N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Tests of physical properties and sampling of water, drinking water, sewage"}],"issue":{"no":"14","date":"30.10.2024"},"map_coord":[49.864032,19.341238],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":44,"microbiology":6},"category_scores":{"water":38.72,"microbiology":0.72},"has_zh":true},"methods":[{"_id":"6a5a55f79af9f73f382520bc","lab_id":"69ad52a3de79e566650fb6b0","country":"PL","accr_number":"AB 1303","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-5:2017-10","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10","methodology_zh":"化学与物理检测用样品采集","search_zh":"生活饮用水 化学与物理检测用样品采集 PN-ISO 5667-5:2017-10","test_object_zh":"生活饮用水"},{"_id":"6a5a55f79af9f73f382520bd","lab_id":"69ad52a3de79e566650fb6b0","country":"PL","accr_number":"AB 1303","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Pobieranie próbek do badań mikrobiologicznych","methodology_en":"Sampling for microbiological testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007","norm_bases":["PN-EN ISO 19458:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 Woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007","categories":["water","microbiology"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007","methodology_zh":"微生物检测用样品采集","search_zh":"生活饮用水 微生物检测用样品采集 PN-EN ISO 19458:2007","test_object_zh":"生活饮用水"},{"_id":"6a5a55f79af9f73f382520be","lab_id":"69ad52a3de79e566650fb6b0","country":"PL","accr_number":"AB 1303","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.5","norm_bases":["PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.5"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.5 Woda Pobieranie probek do badan chemicznych i fizycznych PN-EN ISO 5667-6:2016-12 z wylaczeniem pkt 7.5","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Sampling for chemical and physical testing PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.5","methodology_zh":"化学与物理检测用样品采集","search_zh":"水 化学与物理检测用样品采集 PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.5","test_object_zh":"水"},{"_id":"6a5a55f79af9f73f382520bf","lab_id":"69ad52a3de79e566650fb6b0","country":"PL","accr_number":"AB 1303","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Pobieranie próbek do badań mikrobiologicznych","methodology_en":"Sampling for microbiological testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007","norm_bases":["PN-EN ISO 19458:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 Woda Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007","categories":["water","microbiology"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Sampling for microbiological testing PN-EN ISO 19458:2007","methodology_zh":"微生物检测用样品采集","search_zh":"水 微生物检测用样品采集 PN-EN ISO 19458:2007","test_object_zh":"水"},{"_id":"6a5a55f79af9f73f382520c0","lab_id":"69ad52a3de79e566650fb6b0","country":"PL","accr_number":"AB 1303","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi","test_object_en":"Water Water intended for human consumption","methodology":"pH Zakres: 4,0 – 10,0 Metoda potencjometryczna","methodology_en":"pH Range: 4,0 – 10,0 Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH Zakres: 4,0 – 10,0 Metoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi pH Zakres: 4,0 – 10,0 Metoda potencjometryczna PN-EN ISO 10523:2012 Woda Woda do spozycia przez ludzi pH Zakres: 4,0 – 10,0 Metoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption pH Range: 4,0 – 10,0 Potentiometric method PN-EN ISO 10523:2012","search_zh":"水 生活饮用水 pH 范围：4,0 – 10,0 电位法 PN-EN ISO 10523:2012","test_object_zh":"水 生活饮用水","methodology_zh":"pH 范围：4,0 – 10,0 电位法"},{"_id":"6a5a55f79af9f73f382520c1","lab_id":"69ad52a3de79e566650fb6b0","country":"PL","accr_number":"AB 1303","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi","test_object_en":"Water Water intended for human consumption","methodology":"Przewodność elektryczna właściwa Zakres: (50 – 2500) μS/cm Metoda konduktometryczna","methodology_en":"Electrical conductivity Range: (50 – 2500) μS/cm Conductometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa Zakres: (50 – 2500) μS/cm Metoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi Przewodność elektryczna właściwa Zakres: (50 – 2500) μS/cm Metoda konduktometryczna PN-EN 27888:1999 Woda Woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa Zakres: (50 – 2500) μS/cm Metoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption Electrical conductivity Range: (50 – 2500) μS/cm Conductometric method PN-EN 27888:1999","search_zh":"水 生活饮用水 PN-EN 27888:1999","test_object_zh":"水 生活饮用水"},{"_id":"6a5a55f79af9f73f382520c2","lab_id":"69ad52a3de79e566650fb6b0","country":"PL","accr_number":"AB 1303","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi","test_object_en":"Water Water intended for human consumption","methodology":"Mętność Zakres: (0,20 – 100) NTU Metoda nefelometryczna","methodology_en":"Turbidity Range: (0,20 – 100) NTU Nephelometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Mętność Zakres: (0,20 – 100) NTU Metoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi Mętność Zakres: (0,20 – 100) NTU Metoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda Woda do spozycia przez ludzi Metnosc Zakres: (0,20 – 100) NTU Metoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption Turbidity Range: (0,20 – 100) NTU Nephelometric method PN-EN ISO 7027-1:2016-09","search_zh":"水 生活饮用水 浊度 范围：(0,20 – 100) NTU 散射法 PN-EN ISO 7027-1:2016-09","test_object_zh":"水 生活饮用水","methodology_zh":"浊度 范围：(0,20 – 100) NTU 散射法"},{"_id":"6a5a55f79af9f73f382520c3","lab_id":"69ad52a3de79e566650fb6b0","country":"PL","accr_number":"AB 1303","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi","test_object_en":"Water Water intended for human consumption","methodology":"Barwa Zakres: (5 – 50) mg/l Pt Metoda wizualna","methodology_en":"Colour Range: (5 – 50) mg/l Pt Visual method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Barwa Zakres: (5 – 50) mg/l Pt Metoda wizualna","reference":"PN-EN ISO 7887:2012 Metoda D +Ap1:2015-06","norm_bases":["PN-EN ISO 7887:2012 Metoda D +Ap1:2015-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi Barwa Zakres: (5 – 50) mg/l Pt Metoda wizualna PN-EN ISO 7887:2012 Metoda D +Ap1:2015-06 Woda Woda do spozycia przez ludzi Barwa Zakres: (5 – 50) mg/l Pt Metoda wizualna PN-EN ISO 7887:2012 Metoda D +Ap1:2015-06","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption Colour Range: (5 – 50) mg/l Pt Visual method PN-EN ISO 7887:2012 Metoda D +Ap1:2015-06","search_zh":"水 生活饮用水 PN-EN ISO 7887:2012 Metoda D +Ap1:2015-06","test_object_zh":"水 生活饮用水"},{"_id":"6a5a55f79af9f73f382520c4","lab_id":"69ad52a3de79e566650fb6b0","country":"PL","accr_number":"AB 1303","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi","test_object_en":"Water Water intended for human consumption","methodology":"Zawiesiny ogólne Zakres: (2,0 – 500) mg/l Metoda wagowa","methodology_en":"Total suspended solids (TSS) Range: (2,0 – 500) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawiesiny ogólne Zakres: (2,0 – 500) mg/l Metoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi Zawiesiny ogólne Zakres: (2,0 – 500) mg/l Metoda wagowa PN-EN 872:2007+Ap1:2007 Woda Woda do spozycia przez ludzi Zawiesiny ogolne Zakres: (2,0 – 500) mg/l Metoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption Total suspended solids (TSS) Range: (2,0 – 500) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007","search_zh":"水 生活饮用水 总悬浮物 范围：(2,0 – 500) mg/l 重量法 PN-EN 872:2007+Ap1:2007","test_object_zh":"水 生活饮用水","methodology_zh":"总悬浮物 范围：(2,0 – 500) mg/l 重量法"},{"_id":"6a5a55f79af9f73f382520c5","lab_id":"69ad52a3de79e566650fb6b0","country":"PL","accr_number":"AB 1303","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi","test_object_en":"Water Water intended for human consumption","methodology":"Stężenie jonu amonowego Zakres: (0,050 – 1,00) mg/l Metoda spektrofotometryczna","methodology_en":"Ammonium ion concentration Range: (0,050 – 1,00) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie jonu amonowego Zakres: (0,050 – 1,00) mg/l Metoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi Stężenie jonu amonowego Zakres: (0,050 – 1,00) mg/l Metoda spektrofotometryczna PN-ISO 7150-1:2002 Woda Woda do spozycia przez ludzi Stezenie jonu amonowego Zakres: (0,050 – 1,00) mg/l Metoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption Ammonium ion concentration Range: (0,050 – 1,00) mg/l Spectrophotometric method PN-ISO 7150-1:2002","search_zh":"水 生活饮用水 PN-ISO 7150-1:2002","test_object_zh":"水 生活饮用水"},{"_id":"6a5a55f79af9f73f382520c6","lab_id":"69ad52a3de79e566650fb6b0","country":"PL","accr_number":"AB 1303","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi","test_object_en":"Water Water intended for human consumption","methodology":"Stężenie azotynów Zakres: (0,010 – 0,800) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrite concentration Range: (0,010 – 0,800) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotynów Zakres: (0,010 – 0,800) mg/l Metoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi Stężenie azotynów Zakres: (0,010 – 0,800) mg/l Metoda spektrofotometryczna PN-EN 26777:1999 Woda Woda do spozycia przez ludzi Stezenie azotynow Zakres: (0,010 – 0,800) mg/l Metoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption Nitrite concentration Range: (0,010 – 0,800) mg/l Spectrophotometric method PN-EN 26777:1999","search_zh":"水 生活饮用水 PN-EN 26777:1999","test_object_zh":"水 生活饮用水"},{"_id":"6a5a55f79af9f73f382520c7","lab_id":"69ad52a3de79e566650fb6b0","country":"PL","accr_number":"AB 1303","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi","test_object_en":"Water Water intended for human consumption","methodology":"Stężenie azotanów Zakres: (0,9 – 50,0) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrate concentration Range: (0,9 – 50,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotanów Zakres: (0,9 – 50,0) mg/l Metoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi Stężenie azotanów Zakres: (0,9 – 50,0) mg/l Metoda spektrofotometryczna PN-82/C-04576/08 Woda Woda do spozycia przez ludzi Stezenie azotanow Zakres: (0,9 – 50,0) mg/l Metoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption Nitrate concentration Range: (0,9 – 50,0) mg/l Spectrophotometric method PN-82/C-04576/08","search_zh":"水 生活饮用水 PN-82/C-04576/08","test_object_zh":"水 生活饮用水"},{"_id":"6a5a55f79af9f73f382520c8","lab_id":"69ad52a3de79e566650fb6b0","country":"PL","accr_number":"AB 1303","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi","test_object_en":"Water Water intended for human consumption","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna) Zakres: (10 – 600) mg/l CaCO3 Metoda miareczkowa","methodology_en":"Total calcium and magnesium content (total hardness) Range: (10 – 600) mg/l CaCO3 Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna) Zakres: (10 – 600) mg/l CaCO3 Metoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi Sumaryczna zawartość wapnia i magnezu (twardość ogólna) Zakres: (10 – 600) mg/l CaCO3 Metoda miareczkowa PN-ISO 6059:1999 Woda Woda do spozycia przez ludzi Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna) Zakres: (10 – 600) mg/l CaCO3 Metoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption Total calcium and magnesium content (total hardness) Range: (10 – 600) mg/l CaCO3 Titrimetric method PN-ISO 6059:1999","search_zh":"水 生活饮用水 PN-ISO 6059:1999","test_object_zh":"水 生活饮用水"},{"_id":"6a5a55f79af9f73f382520c9","lab_id":"69ad52a3de79e566650fb6b0","country":"PL","accr_number":"AB 1303","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi","test_object_en":"Water Water intended for human consumption","methodology":"Stężenie żelaza ogólnego Zakres: (20,0 – 1400) µg/l Metoda spektrofotometryczna","methodology_en":"Total iron concentration Range: (20,0 – 1400) µg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie żelaza ogólnego Zakres: (20,0 – 1400) µg/l Metoda spektrofotometryczna","reference":"PB/06/W wydanie 2 z dn. 01.06.2010 na podstawie metody Hach Nr 8147","norm_bases":["PB/06/W wydanie 2 z dn. 01.06.2010 na podstawie metody Hach Nr 8147"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi Stężenie żelaza ogólnego Zakres: (20,0 – 1400) µg/l Metoda spektrofotometryczna PB/06/W wydanie 2 z dn. 01.06.2010 na podstawie metody Hach Nr 8147 Woda Woda do spozycia przez ludzi Stezenie zelaza ogolnego Zakres: (20,0 – 1400) µg/l Metoda spektrofotometryczna PB/06/W wydanie 2 z dn. 01.06.2010 na podstawie metody Hach Nr 8147","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption Total iron concentration Range: (20,0 – 1400) µg/l Spectrophotometric method PB/06/W wydanie 2 z dn. 01.06.2010 na podstawie metody Hach Nr 8147","search_zh":"水 生活饮用水 PB/06/W wydanie 2 z dn. 01.06.2010 na podstawie metody Hach Nr 8147","test_object_zh":"水 生活饮用水"},{"_id":"6a5a55f79af9f73f382520ca","lab_id":"69ad52a3de79e566650fb6b0","country":"PL","accr_number":"AB 1303","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi","test_object_en":"Water Water intended for human consumption","methodology":"Stężenie manganu Zakres: (20,0 – 700) µg/l Metoda spektrofotometryczna","methodology_en":"Manganese concentration Range: (20,0 – 700) µg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie manganu Zakres: (20,0 – 700) µg/l Metoda spektrofotometryczna","reference":"PB/11/W wydanie 2 z dn. 01.06.2010 na podstawie metody Hach Nr 8149","norm_bases":["PB/11/W wydanie 2 z dn. 01.06.2010 na podstawie metody Hach Nr 8149"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi Stężenie manganu Zakres: (20,0 – 700) µg/l Metoda spektrofotometryczna PB/11/W wydanie 2 z dn. 01.06.2010 na podstawie metody Hach Nr 8149 Woda Woda do spozycia przez ludzi Stezenie manganu Zakres: (20,0 – 700) µg/l Metoda spektrofotometryczna PB/11/W wydanie 2 z dn. 01.06.2010 na podstawie metody Hach Nr 8149","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption Manganese concentration Range: (20,0 – 700) µg/l Spectrophotometric method PB/11/W wydanie 2 z dn. 01.06.2010 na podstawie metody Hach Nr 8149","search_zh":"水 生活饮用水 PB/11/W wydanie 2 z dn. 01.06.2010 na podstawie metody Hach Nr 8149","test_object_zh":"水 生活饮用水"},{"_id":"6a5a55f79af9f73f382520cb","lab_id":"69ad52a3de79e566650fb6b0","country":"PL","accr_number":"AB 1303","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi","test_object_en":"Water Water intended for human consumption","methodology":"Stężenie chlorków Zakres: (5,00 – 500) mg/l Metoda miareczkowa","methodology_en":"Chloride concentration Range: (5,00 – 500) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chlorków Zakres: (5,00 – 500) mg/l Metoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi Stężenie chlorków Zakres: (5,00 – 500) mg/l Metoda miareczkowa PN-ISO 9297:1994 Woda Woda do spozycia przez ludzi Stezenie chlorkow Zakres: (5,00 – 500) mg/l Metoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption Chloride concentration Range: (5,00 – 500) mg/l Titrimetric method PN-ISO 9297:1994","search_zh":"水 生活饮用水 PN-ISO 9297:1994","test_object_zh":"水 生活饮用水"},{"_id":"6a5a55f79af9f73f382520cc","lab_id":"69ad52a3de79e566650fb6b0","country":"PL","accr_number":"AB 1303","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5 Zakres: (0,50 - 6,0) mg/l O2 Metoda elektrochemiczna","methodology_en":"Biochemical oxygen demand - BOD5 Range: (0,50 - 6,0) mg/l O2 Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5 Zakres: (0,50 - 6,0) mg/l O2 Metoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Biochemiczne zapotrzebowanie tlenu - BZT5 Zakres: (0,50 - 6,0) mg/l O2 Metoda elektrochemiczna PN-EN 1899-2:2002 Woda Biochemiczne zapotrzebowanie tlenu - BZT5 Zakres: (0,50 - 6,0) mg/l O2 Metoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Biochemical oxygen demand - BOD5 Range: (0,50 - 6,0) mg/l O2 Electrochemical method PN-EN 1899-2:2002","search_zh":"水 PN-EN 1899-2:2002","test_object_zh":"水"},{"_id":"6a5a55f79af9f73f382520cd","lab_id":"69ad52a3de79e566650fb6b0","country":"PL","accr_number":"AB 1303","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr Zakres: (10,0 - 150) mg/l O2 Metoda spektrofotometryczna","methodology_en":"Chemical oxygen demand - COD-Cr Range: (10,0 - 150) mg/l O2 Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr Zakres: (10,0 - 150) mg/l O2 Metoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Chemiczne zapotrzebowanie tlenu - ChZT-Cr Zakres: (10,0 - 150) mg/l O2 Metoda spektrofotometryczna PN-ISO 15705:2005 Woda Chemiczne zapotrzebowanie tlenu - ChZT-Cr Zakres: (10,0 - 150) mg/l O2 Metoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Chemical oxygen demand - COD-Cr Range: (10,0 - 150) mg/l O2 Spectrophotometric method PN-ISO 15705:2005","search_zh":"水 PN-ISO 15705:2005","test_object_zh":"水"},{"_id":"6a5a55f79af9f73f382520ce","lab_id":"69ad52a3de79e566650fb6b0","country":"PL","accr_number":"AB 1303","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi","test_object_en":"Water Water intended for human consumption","methodology":"Ogólna liczba mikroorganizmów w 22 °C Metoda płytkowa, posiew wgłębny","methodology_en":"Total count of microorganisms at 22 °C Plate method, pour plate","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w 22 °C Metoda płytkowa, posiew wgłębny","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 22 °C Metoda płytkowa, posiew wgłębny PN-EN ISO 6222:2004 Woda Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 22 °C Metoda plytkowa, posiew wglebny PN-EN ISO 6222:2004","categories":["water"],"row_index":18,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption Total count of microorganisms at 22 °C Plate method, pour plate PN-EN ISO 6222:2004","search_zh":"水 生活饮用水 PN-EN ISO 6222:2004","test_object_zh":"水 生活饮用水"},{"_id":"6a5a55f79af9f73f382520cf","lab_id":"69ad52a3de79e566650fb6b0","country":"PL","accr_number":"AB 1303","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi","test_object_en":"Water Water intended for human consumption","methodology":"Ogólna liczba mikroorganizmów w 36 °C Metoda płytkowa, posiew wgłębny","methodology_en":"Total count of microorganisms at 36 °C Plate method, pour plate","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w 36 °C Metoda płytkowa, posiew wgłębny","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 36 °C Metoda płytkowa, posiew wgłębny Woda Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 36 °C Metoda plytkowa, posiew wglebny","categories":["water"],"row_index":19,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption Total count of microorganisms at 36 °C Plate method, pour plate","search_zh":"水 生活饮用水","test_object_zh":"水 生活饮用水"},{"_id":"6a5a55f79af9f73f382520d0","lab_id":"69ad52a3de79e566650fb6b0","country":"PL","accr_number":"AB 1303","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi","test_object_en":"Water Water intended for human consumption","methodology":"Liczba bakterii grupy coli Metoda filtracji membranowej","methodology_en":"Coliform bacteria count Membrane filtration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba bakterii grupy coli Metoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12+A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12+A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi Liczba bakterii grupy coli Metoda filtracji membranowej PN-EN ISO 9308-1:2014-12+A1:2017-04 Woda Woda do spozycia przez ludzi Liczba bakterii grupy coli Metoda filtracji membranowej PN-EN ISO 9308-1:2014-12+A1:2017-04","categories":["water","microbiology"],"row_index":20,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12+A1:2017-04","methodology_zh":"大肠菌群计数 膜过滤法","search_zh":"水 生活饮用水 大肠菌群计数 膜过滤法 PN-EN ISO 9308-1:2014-12+A1:2017-04","test_object_zh":"水 生活饮用水"},{"_id":"6a5a55f79af9f73f382520d1","lab_id":"69ad52a3de79e566650fb6b0","country":"PL","accr_number":"AB 1303","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi","test_object_en":"Water Water intended for human consumption","methodology":"Liczba Escherichia coli Metoda filtracji membranowej","methodology_en":"Escherichia coli count Membrane filtration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba Escherichia coli Metoda filtracji membranowej","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi Liczba Escherichia coli Metoda filtracji membranowej Woda Woda do spozycia przez ludzi Liczba Escherichia coli Metoda filtracji membranowej","categories":["water","microbiology"],"row_index":21,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption Escherichia coli count Membrane filtration method","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数 膜过滤法","search_zh":"水 生活饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法","test_object_zh":"水 生活饮用水"},{"_id":"6a5a55f79af9f73f382520d2","lab_id":"69ad52a3de79e566650fb6b0","country":"PL","accr_number":"AB 1303","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi","test_object_en":"Water Water intended for human consumption","methodology":"Najbardziej prawdopodobna liczba bakterii grupy coli Metoda NPL","methodology_en":"Most probable number of coliform bacteria MPN method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Najbardziej prawdopodobna liczba bakterii grupy coli Metoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi Najbardziej prawdopodobna liczba bakterii grupy coli Metoda NPL PN-EN ISO 9308-2:2014-06 Woda Woda do spozycia przez ludzi Najbardziej prawdopodobna liczba bakterii grupy coli Metoda NPL PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":22,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption Most probable number of coliform bacteria MPN method PN-EN ISO 9308-2:2014-06","search_zh":"水 生活饮用水 大肠菌群最可能数 MPN 法 PN-EN ISO 9308-2:2014-06","test_object_zh":"水 生活饮用水","methodology_zh":"大肠菌群最可能数 MPN 法"},{"_id":"6a5a55f79af9f73f382520d3","lab_id":"69ad52a3de79e566650fb6b0","country":"PL","accr_number":"AB 1303","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi","test_object_en":"Water Water intended for human consumption","methodology":"Najbardziej prawdopodobna liczba Escherichia coli Metoda NPL","methodology_en":"Most probable number of Escherichia coli MPN method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Najbardziej prawdopodobna liczba Escherichia coli Metoda NPL","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi Najbardziej prawdopodobna liczba Escherichia coli Metoda NPL Woda Woda do spozycia przez ludzi Najbardziej prawdopodobna liczba Escherichia coli Metoda NPL","categories":["water","microbiology"],"row_index":23,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption Most probable number of Escherichia coli MPN method","search_zh":"水 生活饮用水 大肠埃希氏菌最可能数 MPN 法","test_object_zh":"水 生活饮用水","methodology_zh":"大肠埃希氏菌最可能数 MPN 法"},{"_id":"6a5a55f79af9f73f382520d4","lab_id":"69ad52a3de79e566650fb6b0","country":"PL","accr_number":"AB 1303","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi","test_object_en":"Water Water intended for human consumption","methodology":"Liczba enterokoków kałowych Metoda filtracji membranowej","methodology_en":"Intestinal enterococci count Membrane filtration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba enterokoków kałowych Metoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi Liczba enterokoków kałowych Metoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda Woda do spozycia przez ludzi Liczba enterokokow kalowych Metoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":24,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004","search_zh":"水 生活饮用水 肠球菌计数 膜过滤法 PN-EN ISO 7899-2:2004","test_object_zh":"水 生活饮用水","methodology_zh":"肠球菌计数 膜过滤法"},{"_id":"6a5a55f79af9f73f382520d5","lab_id":"69ad52a3de79e566650fb6b0","country":"PL","accr_number":"AB 1303","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi","test_object_en":"Water Water intended for human consumption","methodology":"Liczba Clostridium perfringens łącznie z przetrwalnikami Metoda filtracji membranowej","methodology_en":"Clostridium perfringens count including spores Membrane filtration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba Clostridium perfringens łącznie z przetrwalnikami Metoda filtracji membranowej","reference":"PN-EN ISO 14189:2016-10","norm_bases":["PN-EN ISO 14189:2016-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi Liczba Clostridium perfringens łącznie z przetrwalnikami Metoda filtracji membranowej PN-EN ISO 14189:2016-10 Woda Woda do spozycia przez ludzi Liczba Clostridium perfringens lacznie z przetrwalnikami Metoda filtracji membranowej PN-EN ISO 14189:2016-10","categories":["water"],"row_index":25,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption Clostridium perfringens count including spores Membrane filtration method PN-EN ISO 14189:2016-10","search_zh":"水 生活饮用水 产气荚膜梭菌数（含芽孢） 膜过滤法 PN-EN ISO 14189:2016-10","test_object_zh":"水 生活饮用水","methodology_zh":"产气荚膜梭菌数（含芽孢） 膜过滤法"},{"_id":"6a5a55f79af9f73f382520d6","lab_id":"69ad52a3de79e566650fb6b0","country":"PL","accr_number":"AB 1303","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna, metoda automatyczna Temperatura pobranej próbki ścieków Zakres: (1,0 – 35) °C","methodology_en":"Sampling for chemical and physical testing Manual method, automatic method Temperature of the wastewater sample taken Range: (1,0 – 35) °C","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna, metoda automatyczna Temperatura pobranej próbki ścieków Zakres: (1,0 – 35) °C","reference":"PN-ISO 5667-10:2021-11 PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11 PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna, metoda automatyczna Temperatura pobranej próbki ścieków Zakres: (1,0 – 35) °C PN-ISO 5667-10:2021-11 PN-77/C-04584 Scieki Pobieranie probek do badan chemicznych i fizycznych Metoda manualna, metoda automatyczna Temperatura pobranej probki sciekow Zakres: (1,0 – 35) °C PN-ISO 5667-10:2021-11 PN-77/C-04584","categories":["water"],"row_index":26,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Sampling for chemical and physical testing Manual method, automatic method Temperature of the wastewater sample taken Range: (1,0 – 35) °C PN-ISO 5667-10:2021-11 PN-77/C-04584","search_zh":"污水 PN-ISO 5667-10:2021-11 PN-77/C-04584","test_object_zh":"污水"},{"_id":"6a5a55f79af9f73f382520d7","lab_id":"69ad52a3de79e566650fb6b0","country":"PL","accr_number":"AB 1303","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"pH Zakres: 4,0 – 10,0 Metoda potencjometryczna","methodology_en":"pH Range: 4,0 – 10,0 Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH Zakres: 4,0 – 10,0 Metoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki pH Zakres: 4,0 – 10,0 Metoda potencjometryczna PN-EN ISO 10523:2012 Scieki pH Zakres: 4,0 – 10,0 Metoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":27,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater pH Range: 4,0 – 10,0 Potentiometric method PN-EN ISO 10523:2012","search_zh":"污水 pH 范围：4,0 – 10,0 电位法 PN-EN ISO 10523:2012","test_object_zh":"污水","methodology_zh":"pH 范围：4,0 – 10,0 电位法"},{"_id":"6a5a55f79af9f73f382520d8","lab_id":"69ad52a3de79e566650fb6b0","country":"PL","accr_number":"AB 1303","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Przewodność elektryczna właściwa Zakres: (147 – 2500) μS/cm Metoda konduktometryczna","methodology_en":"Electrical conductivity Range: (147 – 2500) μS/cm Conductometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa Zakres: (147 – 2500) μS/cm Metoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Przewodność elektryczna właściwa Zakres: (147 – 2500) μS/cm Metoda konduktometryczna PN-EN 27888:1999 Scieki Przewodnosc elektryczna wlasciwa Zakres: (147 – 2500) μS/cm Metoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":28,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Electrical conductivity Range: (147 – 2500) μS/cm Conductometric method PN-EN 27888:1999","search_zh":"污水 PN-EN 27888:1999","test_object_zh":"污水"},{"_id":"6a5a55f79af9f73f382520d9","lab_id":"69ad52a3de79e566650fb6b0","country":"PL","accr_number":"AB 1303","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu amonowego Zakres: (0,050 – 10,0) mg/l Metoda spektrofotometryczna","methodology_en":"Ammonium nitrogen concentration Range: (0,050 – 10,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego Zakres: (0,050 – 10,0) mg/l Metoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu amonowego Zakres: (0,050 – 10,0) mg/l Metoda spektrofotometryczna PN-ISO 7150-1:2002 Scieki Stezenie azotu amonowego Zakres: (0,050 – 10,0) mg/l Metoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":29,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Ammonium nitrogen concentration Range: (0,050 – 10,0) mg/l Spectrophotometric method PN-ISO 7150-1:2002","search_zh":"污水 PN-ISO 7150-1:2002","test_object_zh":"污水"},{"_id":"6a5a55f79af9f73f382520da","lab_id":"69ad52a3de79e566650fb6b0","country":"PL","accr_number":"AB 1303","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu amonowego Zakres: (2,00 – 1000) mg/l Metoda miareczkowa","methodology_en":"Ammonium nitrogen concentration Range: (2,00 – 1000) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego Zakres: (2,00 – 1000) mg/l Metoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu amonowego Zakres: (2,00 – 1000) mg/l Metoda miareczkowa PN-ISO 5664:2002 Scieki Stezenie azotu amonowego Zakres: (2,00 – 1000) mg/l Metoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":30,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Ammonium nitrogen concentration Range: (2,00 – 1000) mg/l Titrimetric method PN-ISO 5664:2002","search_zh":"污水 PN-ISO 5664:2002","test_object_zh":"污水"},{"_id":"6a5a55f79af9f73f382520db","lab_id":"69ad52a3de79e566650fb6b0","country":"PL","accr_number":"AB 1303","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu azotynowego Zakres: (0,010 – 10) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrite nitrogen concentration Range: (0,010 – 10) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego Zakres: (0,010 – 10) mg/l Metoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu azotynowego Zakres: (0,010 – 10) mg/l Metoda spektrofotometryczna PN-EN 26777:1999 Scieki Stezenie azotu azotynowego Zakres: (0,010 – 10) mg/l Metoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":31,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Nitrite nitrogen concentration Range: (0,010 – 10) mg/l Spectrophotometric method PN-EN 26777:1999","search_zh":"污水 PN-EN 26777:1999","test_object_zh":"污水"},{"_id":"6a5a55f79af9f73f382520dc","lab_id":"69ad52a3de79e566650fb6b0","country":"PL","accr_number":"AB 1303","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu azotanowego Zakres: (0,10 – 30) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrate nitrogen concentration Range: (0,10 – 30) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu azotanowego Zakres: (0,10 – 30) mg/l Metoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu azotanowego Zakres: (0,10 – 30) mg/l Metoda spektrofotometryczna PN-82/C-04576/08 Scieki Stezenie azotu azotanowego Zakres: (0,10 – 30) mg/l Metoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":32,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Nitrate nitrogen concentration Range: (0,10 – 30) mg/l Spectrophotometric method PN-82/C-04576/08","search_zh":"污水 PN-82/C-04576/08","test_object_zh":"污水"},{"_id":"6a5a55f79af9f73f382520dd","lab_id":"69ad52a3de79e566650fb6b0","country":"PL","accr_number":"AB 1303","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu Kjeldahla Zakres: (1,00 – 1000) mg/l Metoda miareczkowa","methodology_en":"Kjeldahl nitrogen concentration Range: (1,00 – 1000) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla Zakres: (1,00 – 1000) mg/l Metoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu Kjeldahla Zakres: (1,00 – 1000) mg/l Metoda miareczkowa PN-EN 25663:2001 Scieki Stezenie azotu Kjeldahla Zakres: (1,00 – 1000) mg/l Metoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":33,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Kjeldahl nitrogen concentration Range: (1,00 – 1000) mg/l Titrimetric method PN-EN 25663:2001","search_zh":"污水 凯氏氮浓度 范围：(1,00 – 1000) mg/l 滴定法 PN-EN 25663:2001","test_object_zh":"污水","methodology_zh":"凯氏氮浓度 范围：(1,00 – 1000) mg/l 滴定法"},{"_id":"6a5a55f79af9f73f382520de","lab_id":"69ad52a3de79e566650fb6b0","country":"PL","accr_number":"AB 1303","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu ogólnego (z obliczeń)","methodology_en":"Total nitrogen concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PN-73/C-04576/14","norm_bases":["PN-73/C-04576/14"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu ogólnego (z obliczeń) PN-73/C-04576/14 Scieki Stezenie azotu ogolnego (z obliczen) PN-73/C-04576/14","categories":["water"],"row_index":34,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Total nitrogen concentration (calculated) PN-73/C-04576/14","methodology_zh":"总氮浓度（计算值）","search_zh":"污水 总氮浓度（计算值） PN-73/C-04576/14","test_object_zh":"污水"},{"_id":"6a5a55f79af9f73f382520df","lab_id":"69ad52a3de79e566650fb6b0","country":"PL","accr_number":"AB 1303","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie chlorków Zakres: (5,00 – 5000) mg/l Metoda miareczkowa","methodology_en":"Chloride concentration Range: (5,00 – 5000) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chlorków Zakres: (5,00 – 5000) mg/l Metoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie chlorków Zakres: (5,00 – 5000) mg/l Metoda miareczkowa PN-ISO 9297:1994 Scieki Stezenie chlorkow Zakres: (5,00 – 5000) mg/l Metoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":35,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Chloride concentration Range: (5,00 – 5000) mg/l Titrimetric method PN-ISO 9297:1994","search_zh":"污水 PN-ISO 9297:1994","test_object_zh":"污水"},{"_id":"6a5a55f79af9f73f382520e0","lab_id":"69ad52a3de79e566650fb6b0","country":"PL","accr_number":"AB 1303","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5 Zakres: (3 – 3000) mg/l O2 Metoda elektrochemiczna","methodology_en":"Biochemical oxygen demand - BOD5 Range: (3 – 3000) mg/l O2 Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5 Zakres: (3 – 3000) mg/l O2 Metoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu - BZT5 Zakres: (3 – 3000) mg/l O2 Metoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Scieki Biochemiczne zapotrzebowanie tlenu - BZT5 Zakres: (3 – 3000) mg/l O2 Metoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":36,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Biochemical oxygen demand - BOD5 Range: (3 – 3000) mg/l O2 Electrochemical method PN-EN ISO 5815-1:2019-12","search_zh":"污水 PN-EN ISO 5815-1:2019-12","test_object_zh":"污水"},{"_id":"6a5a55f79af9f73f382520e1","lab_id":"69ad52a3de79e566650fb6b0","country":"PL","accr_number":"AB 1303","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5 Zakres: (0,50 – 6,0) mg/l O2 Metoda elektrochemiczna","methodology_en":"Biochemical oxygen demand - BOD5 Range: (0,50 – 6,0) mg/l O2 Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5 Zakres: (0,50 – 6,0) mg/l O2 Metoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu - BZT5 Zakres: (0,50 – 6,0) mg/l O2 Metoda elektrochemiczna PN-EN 1899-2:2002 Scieki Biochemiczne zapotrzebowanie tlenu - BZT5 Zakres: (0,50 – 6,0) mg/l O2 Metoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":37,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Biochemical oxygen demand - BOD5 Range: (0,50 – 6,0) mg/l O2 Electrochemical method PN-EN 1899-2:2002","search_zh":"污水 PN-EN 1899-2:2002","test_object_zh":"污水"},{"_id":"6a5a55f79af9f73f382520e2","lab_id":"69ad52a3de79e566650fb6b0","country":"PL","accr_number":"AB 1303","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr Zakres: (10,0 – 10000) mg/l O2 Metoda spektrofotometryczna","methodology_en":"Chemical oxygen demand - COD-Cr Range: (10,0 – 10000) mg/l O2 Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr Zakres: (10,0 – 10000) mg/l O2 Metoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr Zakres: (10,0 – 10000) mg/l O2 Metoda spektrofotometryczna PN-ISO 15705:2005 Scieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr Zakres: (10,0 – 10000) mg/l O2 Metoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":38,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Chemical oxygen demand - COD-Cr Range: (10,0 – 10000) mg/l O2 Spectrophotometric method PN-ISO 15705:2005","search_zh":"污水 PN-ISO 15705:2005","test_object_zh":"污水"},{"_id":"6a5a55f79af9f73f382520e3","lab_id":"69ad52a3de79e566650fb6b0","country":"PL","accr_number":"AB 1303","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie fosforu ogólnego Zakres: (0,10 – 50,0) mg/l Metoda spektrofotometryczna","methodology_en":"Total phosphorus concentration Range: (0,10 – 50,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego Zakres: (0,10 – 50,0) mg/l Metoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt 8 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt 8 +Ap1:2010+Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie fosforu ogólnego Zakres: (0,10 – 50,0) mg/l Metoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 8 +Ap1:2010+Ap2:2010 Scieki Stezenie fosforu ogolnego Zakres: (0,10 – 50,0) mg/l Metoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 8 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":39,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Total phosphorus concentration Range: (0,10 – 50,0) mg/l Spectrophotometric method PN-EN ISO 6878:2006 pkt 8 +Ap1:2010+Ap2:2010","search_zh":"污水 PN-EN ISO 6878:2006 pkt 8 +Ap1:2010+Ap2:2010","test_object_zh":"污水"},{"_id":"6a5a55f79af9f73f382520e4","lab_id":"69ad52a3de79e566650fb6b0","country":"PL","accr_number":"AB 1303","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Zawiesiny ogólne Zakres: (2,0 – 5000) mg/l Metoda wagowa","methodology_en":"Total suspended solids (TSS) Range: (2,0 – 5000) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawiesiny ogólne Zakres: (2,0 – 5000) mg/l Metoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Zawiesiny ogólne Zakres: (2,0 – 5000) mg/l Metoda wagowa PN-EN 872:2007+Ap1:2007 Scieki Zawiesiny ogolne Zakres: (2,0 – 5000) mg/l Metoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":40,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Total suspended solids (TSS) Range: (2,0 – 5000) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007","search_zh":"污水 总悬浮物 范围：(2,0 – 5000) mg/l 重量法 PN-EN 872:2007+Ap1:2007","test_object_zh":"污水","methodology_zh":"总悬浮物 范围：(2,0 – 5000) mg/l 重量法"},{"_id":"6a5a55f79af9f73f382520e5","lab_id":"69ad52a3de79e566650fb6b0","country":"PL","accr_number":"AB 1303","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Indeks fenolowy Zakres: (0,002 – 2,6) mg/l Metoda spektrofotometryczna","methodology_en":"Phenol index Range: (0,002 – 2,6) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Indeks fenolowy Zakres: (0,002 – 2,6) mg/l Metoda spektrofotometryczna","reference":"PN-ISO 6439:1994 Metoda B","norm_bases":["PN-ISO 6439:1994 Metoda B"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Indeks fenolowy Zakres: (0,002 – 2,6) mg/l Metoda spektrofotometryczna PN-ISO 6439:1994 Metoda B Scieki Indeks fenolowy Zakres: (0,002 – 2,6) mg/l Metoda spektrofotometryczna PN-ISO 6439:1994 Metoda B","categories":["water"],"row_index":41,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Phenol index Range: (0,002 – 2,6) mg/l Spectrophotometric method PN-ISO 6439:1994 Metoda B","search_zh":"污水 PN-ISO 6439:1994 Metoda B","test_object_zh":"污水"},{"_id":"6a5a55f79af9f73f382520e6","lab_id":"69ad52a3de79e566650fb6b0","country":"PL","accr_number":"AB 1303","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie siarczanów Zakres: (10 – 500) mg/l Metoda wagowa","methodology_en":"Sulfate concentration Range: (10 – 500) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie siarczanów Zakres: (10 – 500) mg/l Metoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie siarczanów Zakres: (10 – 500) mg/l Metoda wagowa PN-ISO 9280:2002 Scieki Stezenie siarczanow Zakres: (10 – 500) mg/l Metoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":42,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Sulfate concentration Range: (10 – 500) mg/l Gravimetric method PN-ISO 9280:2002","search_zh":"污水 硫酸盐浓度 范围：(10 – 500) mg/l 重量法 PN-ISO 9280:2002","test_object_zh":"污水","methodology_zh":"硫酸盐浓度 范围：(10 – 500) mg/l 重量法"},{"_id":"6a5a55f79af9f73f382520e7","lab_id":"69ad52a3de79e566650fb6b0","country":"PL","accr_number":"AB 1303","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie siarczanów Zakres: (10 – 250) mg/l Metoda wagowa","methodology_en":"Sulphate concentration Range: (10 – 250) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie siarczanów Zakres: (10 – 250) mg/l Metoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie siarczanów Zakres: (10 – 250) mg/l Metoda wagowa PN-ISO 9280:2002 Woda Stezenie siarczanow Zakres: (10 – 250) mg/l Metoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":43,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Sulphate concentration Range: (10 – 250) mg/l Gravimetric method PN-ISO 9280:2002","search_zh":"水 PN-ISO 9280:2002","test_object_zh":"水"}],"has_pdf":true}