🇵🇱 dB-PROJEKT Sp. z o.o. PL

PCA AB 1290 • Złotniki, Poland • 17 methods

Environment

dB-PROJEKT Sp. z o.o. is a laboratory accredited by PCA under number AB 1290 (Złotniki, Poland). Its accreditation scope covers 17 test methods in the following areas: Environment. Test objects include: General environment − noise from installations, equipment and indus…, General environment − impulse noise from installations, equipment a…, General environment − noise barriers „in-situ”, General environment − noise from roads, railway lines, tram lines.

At a glance

  • Accreditation number: PCA AB 1290
  • Methods in scope: 17
  • Types of test objects: 8
  • City: Złotniki, Poland
Accreditation number
AB 1290
Accreditation body
PCA
Address
LABORATORIUM BADAWCZE dB-PROJEKT Sp. z o.o., ul. Łagiewnicka 2k/3, 62-002 Złotniki
City
Złotniki, Poland

What this laboratory tests (8)

Accreditation scope — test methods (17)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Rooms in residential, collective residence and public utility buildings − noise A-weighted equivalent sound level A-weighted maximum sound level Range: (25 − 137) dB Direct measurement method PN-87/B-02156
2 Rooms in residential, collective residence and public utility buildings − noise A-weighted equivalent sound level for reference time T (calculated)
3 Wind turbines − noise A-weighted equivalent sound level Sound pressure level in 1/3 octave bands Sound pressure level in the infrasound range: (1 – 20) Hz Range: (25 - 137) dB Direct measurement method PN-EN 61400-11:2004 + Ap1:2006 z wyłączeniem pkt. 8.5
4 Wind turbines − noise Sound power level Directivity (calculated)
5 General environment − noise barriers „in-situ” A-weighted equivalent sound level Range: (25 − 137) dB Sound pressure level in 1/3 octave bands Range: (50 – 10 000) Hz Range: (25 − 137) dB Direct measurement method PN-ISO 10847:2002
6 General environment − noise barriers „in-situ” Effectiveness of screens (calculated)
7 General environment − noise from installations, equipment and industrial plants A-weighted equivalent sound level Range: (25 − 137) dB Direct measurement method nr 7 | enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023 poz. 1706) PN-EN ISO 9613-2:2011
8 General environment − noise from installations, equipment and industrial plants A-weighted equivalent sound level over the reference time T expressed by L AeqD and L ( calculated) AeqN
9 General environment − noise from installations, equipment and industrial plants Calculation method
10 General environment − impulse noise from installations, equipment and industrial plants Maximum A-weighted sound level Equivalent A-weighted sound level A-weighted sound exposure level Range: (25 - 137) dB Direct measurement method nr 8 | enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023 poz. 1706)
11 General environment − impulse noise from installations, equipment and industrial plants A-weighted equivalent sound level over the reference time T expressed by L AeqD and L ( calculated) AeqN
12 General environment − noise from roads, railway lines, tram lines A-weighted equivalent sound level A-weighted sound exposure level Range: (25 − 137) dB Direct measurement method nr 3 | enia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. Nr 140 | Nr 288 | eniem pkt. H
13 General environment − noise from roads, railway lines, tram lines A-weighted equivalent sound level for the reference time T expressed as L and L ( calculated) AeqD AeqN
14 Workplace environment − noise A-weighted equivalent sound level A-weighted maximum sound level Range: (25 − 137) dB C-weighted peak sound level Range: (42 − 140) dB Direct measurement method PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 - punkt 11
15 Workplace environment − noise Noise exposure level referred to: - the 8-hour daily working time - the average weekly working time (calculated)
16 Machinery and equipment − noise A-weighted sound pressure level A-weighted single event sound pressure level Range: (25 – 137) dB Sound pressure level in 1/3 octave bands Range: (50 – 10 000) Hz Range: (25 − 137) dB Direct measurement method PN-EN ISO 3746:2011
17 Machinery and equipment − noise Sound power level Sound energy level (calculated)

Reference standards (13)

Nr 288
PN-87/B-02156
PN-EN 61400-11:2004 + Ap1:2006 z wyłączeniem pkt. 8.5
PN-EN ISO 3746:2011
PN-ISO 10847:2002
PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 - punkt 11
enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023 poz. 1706)
enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023 poz. 1706) PN-EN ISO 9613-2:2011
enia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. Nr 140
eniem pkt. H
nr 3
nr 7