{"lab":{"_id":"69ad52a3de79e566650fb69c","accr_number":"AB 1290","country":"PL","accr_body":"PCA","address":"LABORATORIUM BADAWCZE dB-PROJEKT Sp. z o.o., ul. Łagiewnicka 2k/3, 62-002 Złotniki","categories":["environment"],"city":"Złotniki","imported_at":"2026-03-08T10:42:43.265Z","methods_count":17,"name":"dB-PROJEKT Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1290.pdf"],"scope_summary":"","search_text":"db-projekt sp. z o.o. laboratorium badawcze db-projekt sp. z o.o., ul. łagiewnicka 2k/3, 62-002 złotniki other metrology environment","status":"active","updated_at":"2026-03-08T14:50:28.424Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:28.424Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201290,podmiot.html","parse_date":"2026-07-17T16:19:02.977Z","parse_source":"m5-mistral-qa","fields_of_testing":[{"codes":"A/5, A/13","pl":"Badania akustyczne obiektów budowlanych, maszyn i urządzeń","en":"Acoustic tests of building items, machinery and devices"},{"codes":"G/33, G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne):- środowisko ogólne (czynniki fizyczne - hałas), środowisko pracy (czynniki szkodliwe - hałas)","en":"Tests concerning environmental engineering (environmental and climatic) of general environment (physical factors - noise), working environment (harmful factors - noise),"}],"issue":{"no":"16","date":"27.02.2025"},"map_coord":[52.491639,16.843364],"map_geo":"nominatim-street","has_en":true,"category_counts":{"environment":17},"category_scores":{"environment":17},"has_zh":true},"methods":[{"_id":"6a5a55f69af9f73f38251f7c","lab_id":"69ad52a3de79e566650fb69c","country":"PL","accr_number":"AB 1290","accr_body":"PCA","test_object":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej − hałas","test_object_en":"Rooms in residential, collective residence and public utility buildings − noise","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Zakres: (25 − 137) dB Metoda pomiarowa bezpośrednia","methodology_en":"A-weighted equivalent sound level A-weighted maximum sound level Range: (25 − 137) dB Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Zakres: (25 − 137) dB Metoda pomiarowa bezpośrednia","reference":"PN-87/B-02156","norm_bases":["PN-87/B-02156"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej − hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Zakres: (25 − 137) dB Metoda pomiarowa bezpośrednia PN-87/B-02156 Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i uzytecznosci publicznej − halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A Zakres: (25 − 137) dB Metoda pomiarowa bezposrednia PN-87/B-02156","categories":["environment"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rooms in residential, collective residence and public utility buildings − noise A-weighted equivalent sound level A-weighted maximum sound level Range: (25 − 137) dB Direct measurement method PN-87/B-02156","search_zh":"住宅、集体居住与公共建筑内的房间 － 噪声 PN-87/B-02156","test_object_zh":"住宅、集体居住与公共建筑内的房间 － 噪声"},{"_id":"6a5a55f69af9f73f38251f7d","lab_id":"69ad52a3de79e566650fb69c","country":"PL","accr_number":"AB 1290","accr_body":"PCA","test_object":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej − hałas","test_object_en":"Rooms in residential, collective residence and public utility buildings − noise","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T (z obliczeń)","methodology_en":"A-weighted equivalent sound level for reference time T (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej − hałas Równoważny poziom dźwięku A dla czasu odniesienia T (z obliczeń) Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i uzytecznosci publicznej − halas Rownowazny poziom dzwieku A dla czasu odniesienia T (z obliczen)","categories":["environment"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Rooms in residential, collective residence and public utility buildings − noise A-weighted equivalent sound level for reference time T (calculated)","methodology_zh":"参考时间 T 内的 A 计权等效声级（计算得出）","search_zh":"住宅、集体居住与公共建筑内的房间 － 噪声 参考时间 T 内的 A 计权等效声级（计算得出）","test_object_zh":"住宅、集体居住与公共建筑内的房间 － 噪声"},{"_id":"6a5a55f69af9f73f38251f7e","lab_id":"69ad52a3de79e566650fb69c","country":"PL","accr_number":"AB 1290","accr_body":"PCA","test_object":"Turbiny wiatrowe − hałas","test_object_en":"Wind turbines − noise","methodology":"Równoważny poziom dźwięku A Poziom ciśnienia akustycznego w pasmach 1/3 oktawowych Poziom ciśnienia akustycznego w zakresie infradźwięków: (1 – 20) Hz Zakres: (25 - 137) dB Metoda pomiarowa bezpośrednia","methodology_en":"A-weighted equivalent sound level Sound pressure level in 1/3 octave bands Sound pressure level in the infrasound range: (1 – 20) Hz Range: (25 - 137) dB Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A Poziom ciśnienia akustycznego w pasmach 1/3 oktawowych Poziom ciśnienia akustycznego w zakresie infradźwięków: (1 – 20) Hz Zakres: (25 - 137) dB Metoda pomiarowa bezpośrednia","reference":"PN-EN 61400-11:2004 + Ap1:2006 z wyłączeniem pkt. 8.5","norm_bases":["PN-EN 61400-11:2004 + Ap1:2006 z wyłączeniem pkt. 8.5"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Turbiny wiatrowe − hałas Równoważny poziom dźwięku A Poziom ciśnienia akustycznego w pasmach 1/3 oktawowych Poziom ciśnienia akustycznego w zakresie infradźwięków: (1 – 20) Hz Zakres: (25 - 137) dB Metoda pomiarowa bezpośrednia PN-EN 61400-11:2004 + Ap1:2006 z wyłączeniem pkt. 8.5 Turbiny wiatrowe − halas Rownowazny poziom dzwieku A Poziom cisnienia akustycznego w pasmach 1/3 oktawowych Poziom cisnienia akustycznego w zakresie infradzwiekow: (1 – 20) Hz Zakres: (25 - 137) dB Metoda pomiarowa bezposrednia PN-EN 61400-11:2004 + Ap1:2006 z wylaczeniem pkt. 8.5","categories":["environment"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wind turbines − noise A-weighted equivalent sound level Sound pressure level in 1/3 octave bands Sound pressure level in the infrasound range: (1 – 20) Hz Range: (25 - 137) dB Direct measurement method PN-EN 61400-11:2004 + Ap1:2006 z wyłączeniem pkt. 8.5"},{"_id":"6a5a55f69af9f73f38251f7f","lab_id":"69ad52a3de79e566650fb69c","country":"PL","accr_number":"AB 1290","accr_body":"PCA","test_object":"Turbiny wiatrowe − hałas","test_object_en":"Wind turbines − noise","methodology":"Poziom mocy akustycznej Kierunkowość (z obliczeń)","methodology_en":"Sound power level Directivity (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom mocy akustycznej Kierunkowość (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Turbiny wiatrowe − hałas Poziom mocy akustycznej Kierunkowość (z obliczeń) Turbiny wiatrowe − halas Poziom mocy akustycznej Kierunkowosc (z obliczen)","categories":["environment"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wind turbines − noise Sound power level Directivity (calculated)"},{"_id":"6a5a55f69af9f73f38251f80","lab_id":"69ad52a3de79e566650fb69c","country":"PL","accr_number":"AB 1290","accr_body":"PCA","test_object":"Środowisko ogólne − ekrany akustyczne „in-situ”","test_object_en":"General environment − noise barriers „in-situ”","methodology":"Równoważny poziom dźwięku A Zakres: (25 − 137) dB Poziom ciśnienia akustycznego w pasmach 1/3 oktawowych Zakres: (50 – 10 000) Hz Zakres: (25 − 137) dB Metoda pomiarowa bezpośrednia","methodology_en":"A-weighted equivalent sound level Range: (25 − 137) dB Sound pressure level in 1/3 octave bands Range: (50 – 10 000) Hz Range: (25 − 137) dB Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A Zakres: (25 − 137) dB Poziom ciśnienia akustycznego w pasmach 1/3 oktawowych Zakres: (50 – 10 000) Hz Zakres: (25 − 137) dB Metoda pomiarowa bezpośrednia","reference":"PN-ISO 10847:2002","norm_bases":["PN-ISO 10847:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne − ekrany akustyczne „in-situ” Równoważny poziom dźwięku A Zakres: (25 − 137) dB Poziom ciśnienia akustycznego w pasmach 1/3 oktawowych Zakres: (50 – 10 000) Hz Zakres: (25 − 137) dB Metoda pomiarowa bezpośrednia PN-ISO 10847:2002 Srodowisko ogolne − ekrany akustyczne „in-situ” Rownowazny poziom dzwieku A Zakres: (25 − 137) dB Poziom cisnienia akustycznego w pasmach 1/3 oktawowych Zakres: (50 – 10 000) Hz Zakres: (25 − 137) dB Metoda pomiarowa bezposrednia PN-ISO 10847:2002","categories":["environment"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment − noise barriers „in-situ” A-weighted equivalent sound level Range: (25 − 137) dB Sound pressure level in 1/3 octave bands Range: (50 – 10 000) Hz Range: (25 − 137) dB Direct measurement method PN-ISO 10847:2002"},{"_id":"6a5a55f69af9f73f38251f81","lab_id":"69ad52a3de79e566650fb69c","country":"PL","accr_number":"AB 1290","accr_body":"PCA","test_object":"Środowisko ogólne − ekrany akustyczne „in-situ”","test_object_en":"General environment − noise barriers „in-situ”","methodology":"Skuteczność ekranów (z obliczeń)","methodology_en":"Effectiveness of screens (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczność ekranów (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne − ekrany akustyczne „in-situ” Skuteczność ekranów (z obliczeń) Srodowisko ogolne − ekrany akustyczne „in-situ” Skutecznosc ekranow (z obliczen)","categories":["environment"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment − noise barriers „in-situ” Effectiveness of screens (calculated)","methodology_zh":"屏蔽效能（由计算得出）","search_zh":"屏蔽效能（由计算得出）"},{"_id":"6a5a55f69af9f73f38251f82","lab_id":"69ad52a3de79e566650fb69c","country":"PL","accr_number":"AB 1290","accr_body":"PCA","test_object":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","test_object_en":"General environment − noise from installations, equipment and industrial plants","methodology":"Równoważny poziom dźwięku A Zakres: (25 − 137) dB Metoda pomiarowa bezpośrednia","methodology_en":"A-weighted equivalent sound level Range: (25 − 137) dB Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A Zakres: (25 − 137) dB Metoda pomiarowa bezpośrednia","reference":"nr 7 | enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023 poz. 1706) PN-EN ISO 9613-2:2011","norm_bases":["nr 7","enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023 poz. 1706) PN-EN ISO 9613-2:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A Zakres: (25 − 137) dB Metoda pomiarowa bezpośrednia nr 7 | enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023 poz. 1706) PN-EN ISO 9613-2:2011 Srodowisko ogolne − halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A Zakres: (25 − 137) dB Metoda pomiarowa bezposrednia nr 7 | enia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023 poz. 1706) PN-EN ISO 9613-2:2011","categories":["environment"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment − noise from installations, equipment and industrial plants A-weighted equivalent sound level Range: (25 − 137) dB Direct measurement method nr 7 | enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023 poz. 1706) PN-EN ISO 9613-2:2011","search_zh":"一般环境 − 来自装置、设备和工业企业的噪声 nr 7 | enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023 poz. 1706) PN-EN ISO 9613-2:2011","test_object_zh":"一般环境 − 来自装置、设备和工业企业的噪声"},{"_id":"6a5a55f69af9f73f38251f83","lab_id":"69ad52a3de79e566650fb69c","country":"PL","accr_number":"AB 1290","accr_body":"PCA","test_object":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","test_object_en":"General environment − noise from installations, equipment and industrial plants","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony L AeqD i L ( z obliczeń) AeqN","methodology_en":"A-weighted equivalent sound level over the reference time T expressed by L AeqD and L ( calculated) AeqN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony L AeqD i L ( z obliczeń) AeqN","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony L AeqD i L ( z obliczeń) AeqN Srodowisko ogolne − halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony L AeqD i L ( z obliczen) AeqN","categories":["environment"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment − noise from installations, equipment and industrial plants A-weighted equivalent sound level over the reference time T expressed by L AeqD and L ( calculated) AeqN","search_zh":"一般环境 − 来自装置、设备和工业企业的噪声","test_object_zh":"一般环境 − 来自装置、设备和工业企业的噪声"},{"_id":"6a5a55f69af9f73f38251f84","lab_id":"69ad52a3de79e566650fb69c","country":"PL","accr_number":"AB 1290","accr_body":"PCA","test_object":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","test_object_en":"General environment − noise from installations, equipment and industrial plants","methodology":"Metoda obliczeniowa","methodology_en":"Calculation method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Metoda obliczeniowa","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Metoda obliczeniowa Srodowisko ogolne − halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Metoda obliczeniowa","categories":["environment"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment − noise from installations, equipment and industrial plants Calculation method","methodology_zh":"计算法","search_zh":"一般环境 − 来自装置、设备和工业企业的噪声 计算法","test_object_zh":"一般环境 − 来自装置、设备和工业企业的噪声"},{"_id":"6a5a55f69af9f73f38251f85","lab_id":"69ad52a3de79e566650fb69c","country":"PL","accr_number":"AB 1290","accr_body":"PCA","test_object":"Środowisko ogólne − hałas impulsowy pochodzący od instalacji, urządzeń i zakładów przemysłowych","test_object_en":"General environment − impulse noise from installations, equipment and industrial plants","methodology":"Maksymalny poziom dźwięku A Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A Zakres: (25 - 137) dB Metoda pomiarowa bezpośrednia","methodology_en":"Maximum A-weighted sound level Equivalent A-weighted sound level A-weighted sound exposure level Range: (25 - 137) dB Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Maksymalny poziom dźwięku A Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A Zakres: (25 - 137) dB Metoda pomiarowa bezpośrednia","reference":"nr 8 | enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023 poz. 1706)","norm_bases":["nr 8","enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023 poz. 1706)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne − hałas impulsowy pochodzący od instalacji, urządzeń i zakładów przemysłowych Maksymalny poziom dźwięku A Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A Zakres: (25 - 137) dB Metoda pomiarowa bezpośrednia nr 8 | enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023 poz. 1706) Srodowisko ogolne − halas impulsowy pochodzacy od instalacji, urzadzen i zakladow przemyslowych Maksymalny poziom dzwieku A Rownowazny poziom dzwieku A Ekspozycyjny poziom dzwieku A Zakres: (25 - 137) dB Metoda pomiarowa bezposrednia nr 8 | enia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023 poz. 1706)","categories":["environment"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment − impulse noise from installations, equipment and industrial plants Maximum A-weighted sound level Equivalent A-weighted sound level A-weighted sound exposure level Range: (25 - 137) dB Direct measurement method nr 8 | enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023 poz. 1706)","search_zh":"一般环境 － 来自装置、设备与工业企业的脉冲噪声 nr 8 | enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023 poz. 1706)","test_object_zh":"一般环境 － 来自装置、设备与工业企业的脉冲噪声"},{"_id":"6a5a55f69af9f73f38251f86","lab_id":"69ad52a3de79e566650fb69c","country":"PL","accr_number":"AB 1290","accr_body":"PCA","test_object":"Środowisko ogólne − hałas impulsowy pochodzący od instalacji, urządzeń i zakładów przemysłowych","test_object_en":"General environment − impulse noise from installations, equipment and industrial plants","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony L AeqD i L ( z obliczeń) AeqN","methodology_en":"A-weighted equivalent sound level over the reference time T expressed by L AeqD and L ( calculated) AeqN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony L AeqD i L ( z obliczeń) AeqN","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne − hałas impulsowy pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony L AeqD i L ( z obliczeń) AeqN Srodowisko ogolne − halas impulsowy pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony L AeqD i L ( z obliczen) AeqN","categories":["environment"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment − impulse noise from installations, equipment and industrial plants A-weighted equivalent sound level over the reference time T expressed by L AeqD and L ( calculated) AeqN","search_zh":"一般环境 － 来自装置、设备与工业企业的脉冲噪声","test_object_zh":"一般环境 － 来自装置、设备与工业企业的脉冲噪声"},{"_id":"6a5a55f69af9f73f38251f87","lab_id":"69ad52a3de79e566650fb69c","country":"PL","accr_number":"AB 1290","accr_body":"PCA","test_object":"Środowisko ogólne − hałas pochodzący od dróg, linii kolejowych, linii tramwajowych","test_object_en":"General environment − noise from roads, railway lines, tram lines","methodology":"Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A Zakres: (25 − 137) dB Metoda pomiarowa bezpośrednia","methodology_en":"A-weighted equivalent sound level A-weighted sound exposure level Range: (25 − 137) dB Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A Zakres: (25 − 137) dB Metoda pomiarowa bezpośrednia","reference":"nr 3 | enia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. Nr 140 | Nr 288 | eniem pkt. H","norm_bases":["nr 3","enia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. Nr 140","Nr 288","eniem pkt. H"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne − hałas pochodzący od dróg, linii kolejowych, linii tramwajowych Równoważny poziom dźwięku A Ekspozycyjny poziom dźwięku A Zakres: (25 − 137) dB Metoda pomiarowa bezpośrednia nr 3 | enia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. Nr 140 | Nr 288 | eniem pkt. H Srodowisko ogolne − halas pochodzacy od drog, linii kolejowych, linii tramwajowych Rownowazny poziom dzwieku A Ekspozycyjny poziom dzwieku A Zakres: (25 − 137) dB Metoda pomiarowa bezposrednia nr 3 | enia Ministra Srodowiska z dnia 16.06.2011 r. (Dz. U. Nr 140 | Nr 288 | eniem pkt. H","categories":["environment"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment − noise from roads, railway lines, tram lines A-weighted equivalent sound level A-weighted sound exposure level Range: (25 − 137) dB Direct measurement method nr 3 | enia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. Nr 140 | Nr 288 | eniem pkt. H","search_zh":"一般环境 − 来自道路、铁路线、有轨电车线的噪声 nr 3 | enia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. Nr 140 | Nr 288 | eniem pkt. H","test_object_zh":"一般环境 − 来自道路、铁路线、有轨电车线的噪声"},{"_id":"6a5a55f69af9f73f38251f88","lab_id":"69ad52a3de79e566650fb69c","country":"PL","accr_number":"AB 1290","accr_body":"PCA","test_object":"Środowisko ogólne − hałas pochodzący od dróg, linii kolejowych, linii tramwajowych","test_object_en":"General environment − noise from roads, railway lines, tram lines","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony L i L ( z obliczeń) AeqD AeqN","methodology_en":"A-weighted equivalent sound level for the reference time T expressed as L and L ( calculated) AeqD AeqN","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony L i L ( z obliczeń) AeqD AeqN","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne − hałas pochodzący od dróg, linii kolejowych, linii tramwajowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony L i L ( z obliczeń) AeqD AeqN Srodowisko ogolne − halas pochodzacy od drog, linii kolejowych, linii tramwajowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony L i L ( z obliczen) AeqD AeqN","categories":["environment"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment − noise from roads, railway lines, tram lines A-weighted equivalent sound level for the reference time T expressed as L and L ( calculated) AeqD AeqN","search_zh":"一般环境 − 来自道路、铁路线、有轨电车线的噪声","test_object_zh":"一般环境 − 来自道路、铁路线、有轨电车线的噪声"},{"_id":"6a5a55f69af9f73f38251f89","lab_id":"69ad52a3de79e566650fb69c","country":"PL","accr_number":"AB 1290","accr_body":"PCA","test_object":"Środowisko pracy − hałas","test_object_en":"Workplace environment − noise","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Zakres: (25 − 137) dB Szczytowy poziom dźwięku C Zakres: (42 − 140) dB Metoda pomiarowa bezpośrednia","methodology_en":"A-weighted equivalent sound level A-weighted maximum sound level Range: (25 − 137) dB C-weighted peak sound level Range: (42 − 140) dB Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Zakres: (25 − 137) dB Szczytowy poziom dźwięku C Zakres: (42 − 140) dB Metoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 - punkt 11","norm_bases":["PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 - punkt 11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Zakres: (25 − 137) dB Szczytowy poziom dźwięku C Zakres: (42 − 140) dB Metoda pomiarowa bezpośrednia PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 - punkt 11 Srodowisko pracy − halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A Zakres: (25 − 137) dB Szczytowy poziom dzwieku C Zakres: (42 − 140) dB Metoda pomiarowa bezposrednia PN-N-01307:1994 PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 - punkt 10 i strategie 3 - punkt 11","categories":["environment"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment − noise A-weighted equivalent sound level A-weighted maximum sound level Range: (25 − 137) dB C-weighted peak sound level Range: (42 − 140) dB Direct measurement method PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 - punkt 11","search_zh":"工作环境 − 噪声 PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 - punkt 11","test_object_zh":"工作环境 − 噪声"},{"_id":"6a5a55f69af9f73f38251f8a","lab_id":"69ad52a3de79e566650fb69c","country":"PL","accr_number":"AB 1290","accr_body":"PCA","test_object":"Środowisko pracy − hałas","test_object_en":"Workplace environment − noise","methodology":"Poziom ekspozycji na hałas odniesiony do: - 8-godzinnego dobowego wymiaru czasu pracy - przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","methodology_en":"Noise exposure level referred to: - the 8-hour daily working time - the average weekly working time (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom ekspozycji na hałas odniesiony do: - 8-godzinnego dobowego wymiaru czasu pracy - przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − hałas Poziom ekspozycji na hałas odniesiony do: - 8-godzinnego dobowego wymiaru czasu pracy - przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) Srodowisko pracy − halas Poziom ekspozycji na halas odniesiony do: - 8-godzinnego dobowego wymiaru czasu pracy - przecietnego tygodniowego wymiaru czasu pracy (z obliczen)","categories":["environment"],"row_index":14,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment − noise Noise exposure level referred to: - the 8-hour daily working time - the average weekly working time (calculated)","search_zh":"工作环境 − 噪声 噪声暴露级，参照：－ 每日 8 小时工作时间 － 平均每周工作时间（由计算得出）","test_object_zh":"工作环境 − 噪声","methodology_zh":"噪声暴露级，参照：－ 每日 8 小时工作时间 － 平均每周工作时间（由计算得出）"},{"_id":"6a5a55f69af9f73f38251f8b","lab_id":"69ad52a3de79e566650fb69c","country":"PL","accr_number":"AB 1290","accr_body":"PCA","test_object":"Maszyny i urządzenia − hałas","test_object_en":"Machinery and equipment − noise","methodology":"Poziom ciśnienia akustycznego skorygowany charakterystyką częstotliwościową A Poziom ciśnienia akustycznego pojedynczego zdarzenia skorygowany charakterystyką częstotliwościową A Zakres: (25 – 137) dB Poziom ciśnienia akustycznego w pasmach 1/3 oktawowych Zakres: (50 – 10 000) Hz Zakres: (25 − 137) dB Metoda pomiarowa bezpośrednia","methodology_en":"A-weighted sound pressure level A-weighted single event sound pressure level Range: (25 – 137) dB Sound pressure level in 1/3 octave bands Range: (50 – 10 000) Hz Range: (25 − 137) dB Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom ciśnienia akustycznego skorygowany charakterystyką częstotliwościową A Poziom ciśnienia akustycznego pojedynczego zdarzenia skorygowany charakterystyką częstotliwościową A Zakres: (25 – 137) dB Poziom ciśnienia akustycznego w pasmach 1/3 oktawowych Zakres: (50 – 10 000) Hz Zakres: (25 − 137) dB Metoda pomiarowa bezpośrednia","reference":"PN-EN ISO 3746:2011","norm_bases":["PN-EN ISO 3746:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Maszyny i urządzenia − hałas Poziom ciśnienia akustycznego skorygowany charakterystyką częstotliwościową A Poziom ciśnienia akustycznego pojedynczego zdarzenia skorygowany charakterystyką częstotliwościową A Zakres: (25 – 137) dB Poziom ciśnienia akustycznego w pasmach 1/3 oktawowych Zakres: (50 – 10 000) Hz Zakres: (25 − 137) dB Metoda pomiarowa bezpośrednia PN-EN ISO 3746:2011 Maszyny i urzadzenia − halas Poziom cisnienia akustycznego skorygowany charakterystyka czestotliwosciowa A Poziom cisnienia akustycznego pojedynczego zdarzenia skorygowany charakterystyka czestotliwosciowa A Zakres: (25 – 137) dB Poziom cisnienia akustycznego w pasmach 1/3 oktawowych Zakres: (50 – 10 000) Hz Zakres: (25 − 137) dB Metoda pomiarowa bezposrednia PN-EN ISO 3746:2011","categories":["environment"],"row_index":15,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Machinery and equipment − noise A-weighted sound pressure level A-weighted single event sound pressure level Range: (25 – 137) dB Sound pressure level in 1/3 octave bands Range: (50 – 10 000) Hz Range: (25 − 137) dB Direct measurement method PN-EN ISO 3746:2011","search_zh":"机器与设备 － 噪声 PN-EN ISO 3746:2011","test_object_zh":"机器与设备 － 噪声"},{"_id":"6a5a55f69af9f73f38251f8c","lab_id":"69ad52a3de79e566650fb69c","country":"PL","accr_number":"AB 1290","accr_body":"PCA","test_object":"Maszyny i urządzenia − hałas","test_object_en":"Machinery and equipment − noise","methodology":"Poziom mocy akustycznej Poziom energii akustycznej (z obliczeń)","methodology_en":"Sound power level Sound energy level (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom mocy akustycznej Poziom energii akustycznej (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Maszyny i urządzenia − hałas Poziom mocy akustycznej Poziom energii akustycznej (z obliczeń) Maszyny i urzadzenia − halas Poziom mocy akustycznej Poziom energii akustycznej (z obliczen)","categories":["environment"],"row_index":16,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Machinery and equipment − noise Sound power level Sound energy level (calculated)","search_zh":"机器与设备 － 噪声 声功率级 声能量级（由计算得出）","test_object_zh":"机器与设备 － 噪声","methodology_zh":"声功率级 声能量级（由计算得出）"}],"has_pdf":true}