ANPO LAB PIOTR DOBRZYŃSKI is a laboratory accredited by PCA under number AB 1288 (Białystok, Poland). Its accreditation scope covers 38 test methods in the following areas: Environment. Test objects include: Workplace environment - air, Workplace environment - cold microclimate, Workplace environment - moderate microclimate, Workplace environment - hot microclimate. Most frequently used techniques: Direct measurement method, Gravimetric method, Electrochemical method.
At a glance
- Accreditation number: PCA AB 1288
- Methods in scope: 38
- Types of test objects: 9
- Techniques used: 5
- City: Białystok, Poland
- Accreditation number
- AB 1288
- Accreditation body
- PCA
- Address
- ul. Sybiraków 17/31, 15-204 Białystok, LABORATORIUM, ul. Sukienna 8a/16, 15-881 Białystok
- City
- Białystok, Poland
What this laboratory tests (9)
- Workplace environment - air — 7 methods
- Workplace environment - cold microclimate — 7 methods
- Workplace environment - moderate microclimate — 6 methods
- Workplace environment - hot microclimate — 5 methods
- Workplace environment - noise — 4 methods
- Workplace environment - hand-arm vibration — 3 methods
- Workplace environment - whole-body vibration — 3 methods
- Workplace environment - indoor electric lighting — 2 methods
- Workplace environment - emergency lighting — 1 method
Analytical techniques used (5)
- Direct measurement method — 17 methods
- Gravimetric method — 2 methods
- Electrochemical method — 1 method
- Personal dosimetry method — 1 method
- Personal dosimetry method; Stationary method — 1 method
Laboratory locations
- Laboratorium — ul. Sukienna 8a/16
Accreditation scope — test methods (38)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Laboratory | |||||
| 1 | Workplace environment - noise | A-weighted equivalent sound pressure level Range (25 135) dB |
Direct measurement method | PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11 | |
| 2 | Workplace environment - noise | Maximum A-weighted sound pressure level Range (25 135) dB |
Direct measurement method | PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11 | |
| 3 | Workplace environment - noise | C-weighted peak sound pressure level Range (40 – 135) dB |
Direct measurement method | PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11 | |
| 4 | Workplace environment - noise | Poziom ekspozycji na hałas odniesio-ny do: (z obliczeń) an 8-hour daily working time average weekly working time |
PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11 | ||
| 5 | Workplace environment - indoor electric lighting | Illuminance Range (1 - 10000) lx |
Direct measurement method | Procedura Badawcza PB-01, wydanie 2 z dnia 01.04.2019 r. | |
| 6 | Workplace environment - indoor electric lighting | Illuminance uniformity (calculated) | Procedura Badawcza PB-01, wydanie 2 z dnia 01.04.2019 r. | ||
| 7 | Workplace environment - emergency lighting | Illuminance Range (0,5 - 200) lx |
Direct measurement method | PN-EN 1838:2013-11 | |
| 8 | Workplace environment - whole-body vibration | Frequency-weighted r.m.s. vibration acceleration Range (0,04 - 120) m/s2 |
PN-EN 14253+A1:2011 | ||
| 9 | Workplace environment - whole-body vibration | Ekspozycja dzienna, wyrażona w postaci równoważnego energetycz-nie dla 8-godzin działania skuteczne-go, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczo-nych dla trzech składowych kierunko-wych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń) | PN-EN 14253+A1:2011 | ||
| 10 | Workplace environment - whole-body vibration | Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspie-szenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współ-czynników (1.4awx, 1.4awy, awz) (z obliczeń) | PN-EN 14253+A1:2011 | ||
| 11 | Workplace environment - hand-arm vibration | Skuteczne, ważone częstotliwościowo przyspieszeń drgań Range (0,2 – 150) m/s² |
Direct measurement method | PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 | |
| 12 | Workplace environment - hand-arm vibration | Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przy-spieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń) | PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 | ||
| 13 | Workplace environment - hand-arm vibration | Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwo-ściowo przyspieszeń drgań, wyznaczo-nych dla trzech składowych kierunko-wych (ahwx, ahwy, ahwz) (z obliczeń) | PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 | ||
| 14 | Workplace environment - air | Sampling for the assessment of occupational exposure to: dust agents inhalable fraction respirable fraction metals and their compounds, including inhalable fraction respirable fraction |
Personal dosimetry method | PN-Z-04008-7:2002+Az1:2004 | |
| 15 | Workplace environment - air | Sampling for the assessment of occupational exposure to: organic substances, including inhalable fraction inorganic substances, including inhalable fraction respirable fraction |
Personal dosimetry method; Stationary method | PN-Z-04008-7:2002+Az1:2004 | |
| 16 | Workplace environment - air | Exposure index (calculated) | PN-Z-04008-7:2002+Az1:2004 | ||
| 17 | Workplace environment - air | Gas concentrations CO (2,33 - 250) mg/m3 (2 - 215) ppm NO (0,25- 12,45) mg/m3 (0,2 - 10) ppm NO2 (0,38 – 3,05) mg/m3 (0,2 - 1,6) ppm |
Electrochemical method | Procedura Badawcza PB-02, wydanie 2 z dnia 24.03.2026 r. | |
| 18 | Workplace environment - air | Exposure index (calculated) | Procedura Badawcza PB-02, wydanie 2 z dnia 24.03.2026 r. | ||
| 19 | Workplace environment - air | Concentration of harmful dust agents inhalable fraction Petroleum bitumen Apatites and phosphorites Portland cement Titanium dioxide Natural graphite Synthetic graphite Kaolin Amorphous and synthe-tic silica Wood dusts Flour dusts Dusts not classified according to toxicity Pyły organiczne pochodzenia zwierzę-cego i roślinnego z wyjątkiem pyłów drewna oraz mąki Calcium sulfate (VI) (gypsum) Carbon black Talc Coal (hard, brown) Calcium magnesium carbonate (dolomite) Silicon carbide, non-fibrous Range (0,12 – 20,44) mg/m3 |
Gravimetric method | PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 | |
| 20 | Workplace environment - air | Concentration of harmful dust agents respirable fraction Apatites and phosphorites Portland cement Natural graphite Amorphous and synthe-tic silica Pyły organiczne pochodzenia zwierzę-cego i roślinnego z wyjątkiem pyłów drewna oraz mąki Talc Coal (hard, brown) Range (0,07 – 15,49) mg/m3 |
Gravimetric method | PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 | |
| 21 | Workplace environment - hot microclimate | Air temperature Range (10 - 60) °C |
Direct measurement method | PN-EN ISO 7243:2018-01+Ap2:2020-04 | |
| 22 | Workplace environment - hot microclimate | Natural wet bulb temperature Range (5 - 60) °C |
Direct measurement method | PN-EN ISO 7243:2018-01+Ap2:2020-04 | |
| 23 | Workplace environment - hot microclimate | Black globe temperature Range (10 - 60) °C |
Direct measurement method | PN-EN ISO 7243:2018-01+Ap2:2020-04 | |
| 24 | Workplace environment - hot microclimate | WBGT index (calculated) | PN-EN ISO 7243:2018-01+Ap2:2020-04 | ||
| 25 | Workplace environment - hot microclimate | WBGTeff index (calculated) | PN-EN ISO 7243:2018-01+Ap2:2020-04 | ||
| 26 | Workplace environment - cold microclimate | Air temperature Range (-30 - 10) °C |
Direct measurement method | PN-EN ISO 11079:2008 | |
| 27 | Workplace environment - cold microclimate | Black globe temperature Range (-30 - 10) °C |
Direct measurement method | PN-EN ISO 11079:2008 | |
| 28 | Workplace environment - cold microclimate | Air humidity Range (20 - 90) % |
Direct measurement method | PN-EN ISO 11079:2008 | |
| 29 | Workplace environment - cold microclimate | Air velocity Range (0,15 - 5) m/s |
Direct measurement method | PN-EN ISO 11079:2008 | |
| 30 | Workplace environment - cold microclimate | Wskaźnik IREQmin (z obliczeń) | PN-EN ISO 11079:2008 | ||
| 31 | Workplace environment - cold microclimate | IREQneutral index (calculated) | PN-EN ISO 11079:2008 | ||
| 32 | Workplace environment - cold microclimate | Wskaźnik tWC (z obliczeń) | PN-EN ISO 11079:2008 | ||
| 33 | Workplace environment - moderate microclimate | Air temperature Range (10 - 30) °C |
Direct measurement method | PN-EN ISO 7730:2006+Ap2:2016-04 | |
| 34 | Workplace environment - moderate microclimate | Black globe temperature Range (10 - 40) °C |
Direct measurement method | PN-EN ISO 7730:2006+Ap2:2016-04 | |
| 35 | Workplace environment - moderate microclimate | Air humidity Range (20 - 90) % |
Direct measurement method | PN-EN ISO 7730:2006+Ap2:2016-04 | |
| 36 | Workplace environment - moderate microclimate | Air velocity Range (0,15 - 1) m/s |
Direct measurement method | PN-EN ISO 7730:2006+Ap2:2016-04 | |
| 37 | Workplace environment - moderate microclimate | Wskaźnik PMV (z obliczeń) | PN-EN ISO 7730:2006+Ap2:2016-04 | ||
| 38 | Workplace environment - moderate microclimate | PPD index (calculated) | PN-EN ISO 7730:2006+Ap2:2016-04 | ||
Reference standards (17)
PN-EN 14253+A1:2011
PN-EN 1838:2013-11
PN-EN ISO 11079:2008
PN-EN ISO 5349-1:2004
PN-EN ISO 5349-2:2004
PN-EN ISO 5349-2:2004/A1:2015-11
PN-EN ISO 7243:2018-01+Ap2:2020-04
PN-EN ISO 7730:2006+Ap2:2016-04
PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11
PN-N-01307:1994
PN-Z-04008-7:2002+Az1:2004
PN-Z-04507:2022-05
PN-Z-04507:2022-05/Ap1:2022-08
PN-Z-04508:2022-05
PN-Z-04508:2022-05/Ap1:2022-08
Procedura Badawcza PB-01, wydanie 2 z dnia 01.04.2019 r.