{"lab":{"_id":"69ad52a3de79e566650fb69a","accr_number":"AB 1288","country":"PL","accr_body":"PCA","address":"ul. Sybiraków 17/31, 15-204 Białystok, LABORATORIUM, ul. Sukienna 8a/16, 15-881 Białystok","categories":["environment"],"city":"Białystok","imported_at":"2026-03-08T10:42:43.265Z","methods_count":38,"name":"ANPO LAB PIOTR DOBRZYŃSKI","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1288.pdf"],"scope_summary":"","search_text":"anpo lab piotr dobrzyński ul. sybiraków 17/31, 15-204 białystok, laboratorium, ul. sukienna 8a/16, 15-881 białystok environment metrology other materials construction electronics","status":"active","updated_at":"2026-03-08T14:50:28.300Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T10:10:03.510Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201288,podmiot.html","parse_date":"2026-08-17T10:10:03.510Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"C/33","pl":"Badania chemiczne – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Chemical tests - working environment (harmful factors - air)"},{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe i uciążliwe – hałas, drgania, oświetlenie, mikroklimat)","en":"Tests concerning environmental en-gineering (environmental and climatic) – working environment (harmful and nuisance factors – noise, vibration, lighting, microclimate)"},{"codes":"N/33/P","pl":"Badania właściwości fizycznych i pobieranie próbek – środowisko pracy (czynniki szkodliwe – powietrze)","en":"Tests of physical properties and sampling - working environment (harmful factors - air)"},{"codes":"P/33","pl":"Pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Sampling - working environment (harmful factors - air)"}],"issue":{"no":"19","date":"21.07.2026"},"map_coord":[53.131965,23.199331],"map_geo":"nominatim-street","lab_locations":[{"name":"Laboratorium","address":"ul. Sukienna 8a/16","city":"Białystok","postal":"15-881"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/2349c955c0c06fc1f713e3f665d33779/AB%201288.pdf","has_en":true,"category_counts":{"environment":38,"construction":2,"materials":1},"category_scores":{"environment":35.22,"construction":0.1,"materials":0.02},"has_zh":true,"lab_locations_zh":[{"name":"实验室","address":"ul. Sukienna 8a/16","city":"Białystok","postal":"15-881"}]},"methods":[{"_id":"6a82ddfb884ede9a1b2c34d8","lab_id":"69ad52a3de79e566650fb69a","country":"PL","accr_number":"AB 1288","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(25 135) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres (25 135) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Równoważny poziom dźwięku A\nZakres (25 135) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11 Srodowisko pracy - halas Rownowazny poziom dzwieku A\nZakres (25 135) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 i 3 – punkt 10 i 11","categories":["environment"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"A-weighted equivalent sound pressure level","parameters_en":[{"name":"Range","range":"(25 135) dB"}],"search_en":"Workplace environment - noise A-weighted equivalent sound pressure level Direct measurement method Laboratory Range PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","technique_en":"Direct measurement method","test_object_en":"Workplace environment - noise","lab_section_zh":"实验室","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(25 135) dB"}],"search_zh":"工作场所环境 — 噪声 A 计权等效声级 直接测量法 实验室 范围 PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a82ddfb884ede9a1b2c34d9","lab_id":"69ad52a3de79e566650fb69a","country":"PL","accr_number":"AB 1288","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(25 135) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Maksymalny poziom dźwięku A\nZakres (25 135) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Maksymalny poziom dźwięku A\nZakres (25 135) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11 Srodowisko pracy - halas Maksymalny poziom dzwieku A\nZakres (25 135) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 i 3 – punkt 10 i 11","categories":["environment"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Maximum A-weighted sound pressure level","parameters_en":[{"name":"Range","range":"(25 135) dB"}],"search_en":"Workplace environment - noise Maximum A-weighted sound pressure level Direct measurement method Laboratory Range PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","technique_en":"Direct measurement method","test_object_en":"Workplace environment - noise","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(25 135) dB"}],"search_zh":"工作场所环境 — 噪声 A 计权最大声级 直接测量法 实验室 范围 PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声","methodology_zh":"A 计权最大声级"},{"_id":"6a82ddfb884ede9a1b2c34da","lab_id":"69ad52a3de79e566650fb69a","country":"PL","accr_number":"AB 1288","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Szczytowy poziom dźwięku C","parameters":[{"name":"Zakres","range":"(40 – 135) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Szczytowy poziom dźwięku C\nZakres (40 – 135) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Szczytowy poziom dźwięku C\nZakres (40 – 135) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11 Srodowisko pracy - halas Szczytowy poziom dzwieku C\nZakres (40 – 135) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 i 3 – punkt 10 i 11","categories":["environment"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"C-weighted peak sound pressure level","parameters_en":[{"name":"Range","range":"(40 – 135) dB"}],"search_en":"Workplace environment - noise C-weighted peak sound pressure level Direct measurement method Laboratory Range PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","technique_en":"Direct measurement method","test_object_en":"Workplace environment - noise","lab_section_zh":"实验室","methodology_zh":"C 计权峰值声级","parameters_zh":[{"name":"范围","range":"(40 – 135) dB"}],"search_zh":"工作场所环境 — 噪声 C 计权峰值声级 直接测量法 实验室 范围 PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a82ddfb884ede9a1b2c34db","lab_id":"69ad52a3de79e566650fb69a","country":"PL","accr_number":"AB 1288","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Poziom ekspozycji na hałas odniesio-ny do: (z obliczeń)","parameters":[{"name":"8 godzinnego dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy"}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas odniesio-ny do: (z obliczeń)\nZakres:\n8 godzinnego dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Poziom ekspozycji na hałas odniesio-ny do: (z obliczeń)\nZakres:\n8 godzinnego dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11 Srodowisko pracy - halas Poziom ekspozycji na halas odniesio-ny do: (z obliczen)\nZakres:\n8 godzinnego dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 i 3 – punkt 10 i 11","categories":["environment"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","parameters_en":[{"name":"an 8-hour daily working time"},{"name":"average weekly working time"}],"search_en":"Workplace environment - noise Laboratory an 8-hour daily working time average weekly working time PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","test_object_en":"Workplace environment - noise","lab_section_zh":"实验室","search_zh":"工作场所环境 — 噪声 实验室 8 小时日工作时间 PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","test_object_zh":"工作场所环境 — 噪声","parameters_zh":[{"name":"8 小时日工作时间"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy"}]},{"_id":"6a82ddfb884ede9a1b2c34dc","lab_id":"69ad52a3de79e566650fb69a","country":"PL","accr_number":"AB 1288","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne we wnętrzach","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(1 - 10000) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (1 - 10000) lx\nMetoda pomiarowa bezpośrednia","reference":"Procedura Badawcza PB-01, wydanie 2 z dnia 01.04.2019 r.","norm_bases":["Procedura Badawcza PB-01, wydanie 2 z dnia 01.04.2019 r."],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie elektryczne we wnętrzach Natężenie oświetlenia\nZakres (1 - 10000) lx\nMetoda pomiarowa bezpośrednia Procedura Badawcza PB-01, wydanie 2 z dnia 01.04.2019 r. Srodowisko pracy - oswietlenie elektryczne we wnetrzach Natezenie oswietlenia\nZakres (1 - 10000) lx\nMetoda pomiarowa bezposrednia Procedura Badawcza PB-01, wydanie 2 z dnia 01.04.2019 r.","categories":["environment"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Illuminance","parameters_en":[{"name":"Range","range":"(1 - 10000) lx"}],"search_en":"Workplace environment - indoor electric lighting Illuminance Direct measurement method Laboratory Range Procedura Badawcza PB-01, wydanie 2 z dnia 01.04.2019 r.","technique_en":"Direct measurement method","test_object_en":"Workplace environment - indoor electric lighting","lab_section_zh":"实验室","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(1 - 10000) lx"}],"search_zh":"工作场所环境 — 室内电气照明 照度 直接测量法 实验室 范围 Procedura Badawcza PB-01, wydanie 2 z dnia 01.04.2019 r.","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 室内电气照明"},{"_id":"6a82ddfb884ede9a1b2c34dd","lab_id":"69ad52a3de79e566650fb69a","country":"PL","accr_number":"AB 1288","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne we wnętrzach","methodology":"Równomierność oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"Procedura Badawcza PB-01, wydanie 2 z dnia 01.04.2019 r.","norm_bases":["Procedura Badawcza PB-01, wydanie 2 z dnia 01.04.2019 r."],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie elektryczne we wnętrzach Równomierność oświetlenia (z obliczeń) Procedura Badawcza PB-01, wydanie 2 z dnia 01.04.2019 r. Srodowisko pracy - oswietlenie elektryczne we wnetrzach Rownomiernosc oswietlenia (z obliczen) Procedura Badawcza PB-01, wydanie 2 z dnia 01.04.2019 r.","categories":["environment"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Illuminance uniformity (calculated)","search_en":"Workplace environment - indoor electric lighting Illuminance uniformity (calculated) Laboratory Procedura Badawcza PB-01, wydanie 2 z dnia 01.04.2019 r.","test_object_en":"Workplace environment - indoor electric lighting","lab_section_zh":"实验室","methodology_zh":"照度均匀度（计算值）","search_zh":"工作场所环境 — 室内电气照明 照度均匀度（计算值） 实验室 Procedura Badawcza PB-01, wydanie 2 z dnia 01.04.2019 r.","test_object_zh":"工作场所环境 — 室内电气照明"},{"_id":"6a82ddfb884ede9a1b2c34de","lab_id":"69ad52a3de79e566650fb69a","country":"PL","accr_number":"AB 1288","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie awaryjne","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(0,5 - 200) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (0,5 - 200) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 1838:2013-11","norm_bases":["PN-EN 1838:2013-11"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie awaryjne Natężenie oświetlenia\nZakres (0,5 - 200) lx\nMetoda pomiarowa bezpośrednia PN-EN 1838:2013-11 Srodowisko pracy - oswietlenie awaryjne Natezenie oswietlenia\nZakres (0,5 - 200) lx\nMetoda pomiarowa bezposrednia PN-EN 1838:2013-11","categories":["environment"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Illuminance","parameters_en":[{"name":"Range","range":"(0,5 - 200) lx"}],"search_en":"Workplace environment - emergency lighting Illuminance Direct measurement method Laboratory Range PN-EN 1838:2013-11","technique_en":"Direct measurement method","test_object_en":"Workplace environment - emergency lighting","lab_section_zh":"实验室","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(0,5 - 200) lx"}],"search_zh":"工作场所环境 — 应急照明 照度 直接测量法 实验室 范围 PN-EN 1838:2013-11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 应急照明"},{"_id":"6a82ddfb884ede9a1b2c34df","lab_id":"69ad52a3de79e566650fb69a","country":"PL","accr_number":"AB 1288","accr_body":"PCA","test_object":"Środowisko pracy - drgania o ogólnym działaniu na organizm człowieka","methodology":"Skuteczne, ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,04 - 120) m/s2"}],"technique":null,"techniques":[],"computed":[],"activity":"Skuteczne, ważone częstotliwościowo przyspieszenie drgań\nZakres (0,04 - 120) m/s2","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - drgania o ogólnym działaniu na organizm człowieka Skuteczne, ważone częstotliwościowo przyspieszenie drgań\nZakres (0,04 - 120) m/s2 PN-EN 14253+A1:2011 Srodowisko pracy - drgania o ogolnym dzialaniu na organizm czlowieka Skuteczne, wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,04 - 120) m/s2 PN-EN 14253+A1:2011","categories":["environment"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters_en":[{"name":"Range","range":"(0,04 - 120) m/s2"}],"search_en":"Workplace environment - whole-body vibration Frequency-weighted r.m.s. vibration acceleration Laboratory Range PN-EN 14253+A1:2011","test_object_en":"Workplace environment - whole-body vibration","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,04 - 120) m/s2"}],"search_zh":"工作场所环境 — 全身振动 实验室 范围 PN-EN 14253+A1:2011","test_object_zh":"工作场所环境 — 全身振动"},{"_id":"6a82ddfb884ede9a1b2c34e0","lab_id":"69ad52a3de79e566650fb69a","country":"PL","accr_number":"AB 1288","accr_body":"PCA","test_object":"Środowisko pracy - drgania o ogólnym działaniu na organizm człowieka","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycz-nie dla 8-godzin działania skuteczne-go, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczo-nych dla trzech składowych kierunko-wych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycz-nie dla 8-godzin działania skuteczne-go, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczo-nych dla trzech składowych kierunko-wych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń)","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - drgania o ogólnym działaniu na organizm człowieka Ekspozycja dzienna, wyrażona w postaci równoważnego energetycz-nie dla 8-godzin działania skuteczne-go, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczo-nych dla trzech składowych kierunko-wych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń) PN-EN 14253+A1:2011 Srodowisko pracy - drgania o ogolnym dzialaniu na organizm czlowieka Ekspozycja dzienna, wyrazona w postaci rownowaznego energetycz-nie dla 8-godzin dzialania skuteczne-go, skorygowanego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczo-nych dla trzech skladowych kierunko-wych z uwzglednieniem wlasciwych wspolczynnikow (1.4awx, 1.4awy, awz) (z obliczen) PN-EN 14253+A1:2011","categories":["environment"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","search_en":"Workplace environment - whole-body vibration Laboratory PN-EN 14253+A1:2011","test_object_en":"Workplace environment - whole-body vibration","lab_section_zh":"实验室","search_zh":"工作场所环境 — 全身振动 实验室 PN-EN 14253+A1:2011","test_object_zh":"工作场所环境 — 全身振动"},{"_id":"6a82ddfb884ede9a1b2c34e1","lab_id":"69ad52a3de79e566650fb69a","country":"PL","accr_number":"AB 1288","accr_body":"PCA","test_object":"Środowisko pracy - drgania o ogólnym działaniu na organizm człowieka","methodology":"Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspie-szenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współ-czynników (1.4awx, 1.4awy, awz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspie-szenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współ-czynników (1.4awx, 1.4awy, awz) (z obliczeń)","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - drgania o ogólnym działaniu na organizm człowieka Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspie-szenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współ-czynników (1.4awx, 1.4awy, awz) (z obliczeń) PN-EN 14253+A1:2011 Srodowisko pracy - drgania o ogolnym dzialaniu na organizm czlowieka Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci skutecznego, wazonego czestotliwosciowo przyspie-szenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspol-czynnikow (1.4awx, 1.4awy, awz) (z obliczen) PN-EN 14253+A1:2011","categories":["environment"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","search_en":"Workplace environment - whole-body vibration Laboratory PN-EN 14253+A1:2011","test_object_en":"Workplace environment - whole-body vibration","lab_section_zh":"实验室","search_zh":"工作场所环境 — 全身振动 实验室 PN-EN 14253+A1:2011","test_object_zh":"工作场所环境 — 全身振动"},{"_id":"6a82ddfb884ede9a1b2c34e2","lab_id":"69ad52a3de79e566650fb69a","country":"PL","accr_number":"AB 1288","accr_body":"PCA","test_object":"Środowisko pracy - drgania działające na organizm człowieka przez kończyny górne","methodology":"Skuteczne, ważone częstotliwościowo przyspieszeń drgań","parameters":[{"name":"Zakres","range":"(0,2 – 150) m/s²"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne, ważone częstotliwościowo przyspieszeń drgań\nZakres (0,2 – 150) m/s²\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - drgania działające na organizm człowieka przez kończyny górne Skuteczne, ważone częstotliwościowo przyspieszeń drgań\nZakres (0,2 – 150) m/s²\nMetoda pomiarowa bezpośrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy - drgania dzialajace na organizm czlowieka przez konczyny gorne Skuteczne, wazone czestotliwosciowo przyspieszen drgan\nZakres (0,2 – 150) m/s²\nMetoda pomiarowa bezposrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","parameters_en":[{"name":"Range","range":"(0,2 – 150) m/s²"}],"search_en":"Workplace environment - hand-arm vibration Direct measurement method Laboratory Range PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","technique_en":"Direct measurement method","test_object_en":"Workplace environment - hand-arm vibration","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,2 – 150) m/s²"}],"search_zh":"工作场所环境 — 手传振动 直接测量法 实验室 范围 PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 手传振动"},{"_id":"6a82ddfb884ede9a1b2c34e3","lab_id":"69ad52a3de79e566650fb69a","country":"PL","accr_number":"AB 1288","accr_body":"PCA","test_object":"Środowisko pracy - drgania działające na organizm człowieka przez kończyny górne","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przy-spieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przy-spieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - drgania działające na organizm człowieka przez kończyny górne Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przy-spieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy - drgania dzialajace na organizm czlowieka przez konczyny gorne Ekspozycja dzienna, wyrazona w postaci rownowaznej energetycznie dla 8-godzin dzialania sumy wektorowej skutecznych, skorygowanych czestotliwosciowo przy-spieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz) (z obliczen) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","search_en":"Workplace environment - hand-arm vibration Laboratory PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","test_object_en":"Workplace environment - hand-arm vibration","lab_section_zh":"实验室","search_zh":"工作场所环境 — 手传振动 实验室 PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","test_object_zh":"工作场所环境 — 手传振动"},{"_id":"6a82ddfb884ede9a1b2c34e4","lab_id":"69ad52a3de79e566650fb69a","country":"PL","accr_number":"AB 1288","accr_body":"PCA","test_object":"Środowisko pracy - drgania działające na organizm człowieka przez kończyny górne","methodology":"Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwo-ściowo przyspieszeń drgań, wyznaczo-nych dla trzech składowych kierunko-wych (ahwx, ahwy, ahwz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwo-ściowo przyspieszeń drgań, wyznaczo-nych dla trzech składowych kierunko-wych (ahwx, ahwy, ahwz) (z obliczeń)","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - drgania działające na organizm człowieka przez kończyny górne Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwo-ściowo przyspieszeń drgań, wyznaczo-nych dla trzech składowych kierunko-wych (ahwx, ahwy, ahwz) (z obliczeń) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy - drgania dzialajace na organizm czlowieka przez konczyny gorne Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci sumy wektorowej skutecznych, wazonych czestotliwo-sciowo przyspieszen drgan, wyznaczo-nych dla trzech skladowych kierunko-wych (ahwx, ahwy, ahwz) (z obliczen) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","search_en":"Workplace environment - hand-arm vibration Laboratory PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","test_object_en":"Workplace environment - hand-arm vibration","lab_section_zh":"实验室","search_zh":"工作场所环境 — 手传振动 实验室 PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","test_object_zh":"工作场所环境 — 手传振动"},{"_id":"6a82ddfb884ede9a1b2c34e5","lab_id":"69ad52a3de79e566650fb69a","country":"PL","accr_number":"AB 1288","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","parameters":[{"name":"czynniki pyłowe"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"},{"name":"metale i ich związki, w tym"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe\nfrakcja wdychalna\nfrakcja respirabilna\nmetale i ich związki, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe\nfrakcja wdychalna\nfrakcja respirabilna\nmetale i ich związki, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy - powietrze Pobieranie probek do oceny narazenia zawodowego na:\nZakres:\nczynniki pylowe\nfrakcja wdychalna\nfrakcja respirabilna\nmetale i ich zwiazki, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004","categories":["materials","environment"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"dust agents"},{"name":"inhalable fraction"},{"name":"respirable fraction"},{"name":"metals and their compounds, including"},{"name":"inhalable fraction"},{"name":"respirable fraction"}],"search_en":"Workplace environment - air Sampling for the assessment of occupational exposure to: Personal dosimetry method Laboratory dust agents inhalable fraction respirable fraction metals and their compounds, including inhalable fraction respirable fraction PN-Z-04008-7:2002+Az1:2004","technique_en":"Personal dosimetry method","test_object_en":"Workplace environment - air","lab_section_zh":"实验室","methodology_zh":"职业接触评估采样，针对：","parameters_zh":[{"name":"粉尘因素"},{"name":"可吸入组分"},{"name":"呼吸性组分"},{"name":"金属及其化合物，包括"},{"name":"可吸入组分"},{"name":"呼吸性组分"}],"search_zh":"工作场所环境 — 空气 职业接触评估采样，针对： 个体剂量测定法 实验室 粉尘因素 可吸入组分 呼吸性组分 金属及其化合物，包括 可吸入组分 呼吸性组分 PN-Z-04008-7:2002+Az1:2004","technique_zh":"个体剂量测定法","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a82ddfb884ede9a1b2c34e6","lab_id":"69ad52a3de79e566650fb69a","country":"PL","accr_number":"AB 1288","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","parameters":[{"name":"substancje organiczne, w tym"},{"name":"frakcja wdychalna"},{"name":"substancje nieorganiczne, w tym"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"}],"technique":"Metoda dozymetrii indywidualnej; Metoda stacjonarna","techniques":["Metoda dozymetrii indywidualnej","Metoda stacjonarna"],"computed":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nsubstancje organiczne, w tym\nfrakcja wdychalna\nsubstancje nieorganiczne, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej; Metoda stacjonarna","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nsubstancje organiczne, w tym\nfrakcja wdychalna\nsubstancje nieorganiczne, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej; Metoda stacjonarna PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy - powietrze Pobieranie probek do oceny narazenia zawodowego na:\nZakres:\nsubstancje organiczne, w tym\nfrakcja wdychalna\nsubstancje nieorganiczne, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej; Metoda stacjonarna PN-Z-04008-7:2002+Az1:2004","categories":["environment"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"organic substances, including"},{"name":"inhalable fraction"},{"name":"inorganic substances, including"},{"name":"inhalable fraction"},{"name":"respirable fraction"}],"search_en":"Workplace environment - air Sampling for the assessment of occupational exposure to: Personal dosimetry method; Stationary method Laboratory organic substances, including inhalable fraction inorganic substances, including inhalable fraction respirable fraction PN-Z-04008-7:2002+Az1:2004","technique_en":"Personal dosimetry method; Stationary method","test_object_en":"Workplace environment - air","lab_section_zh":"实验室","methodology_zh":"职业接触评估采样，针对：","parameters_zh":[{"name":"有机物质，包括"},{"name":"可吸入组分"},{"name":"无机物质，包括"},{"name":"可吸入组分"},{"name":"呼吸性组分"}],"search_zh":"工作场所环境 — 空气 职业接触评估采样，针对： 个体剂量测定法；定点测定法 实验室 有机物质，包括 可吸入组分 无机物质，包括 可吸入组分 呼吸性组分 PN-Z-04008-7:2002+Az1:2004","test_object_zh":"工作场所环境 — 空气","technique_zh":"个体剂量测定法；定点测定法"},{"_id":"6a82ddfb884ede9a1b2c34e7","lab_id":"69ad52a3de79e566650fb69a","country":"PL","accr_number":"AB 1288","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy - powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002+Az1:2004","categories":["environment"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Exposure index (calculated)","search_en":"Workplace environment - air Exposure index (calculated) Laboratory PN-Z-04008-7:2002+Az1:2004","test_object_en":"Workplace environment - air","lab_section_zh":"实验室","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出） 实验室 PN-Z-04008-7:2002+Az1:2004","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a82ddfb884ede9a1b2c34e8","lab_id":"69ad52a3de79e566650fb69a","country":"PL","accr_number":"AB 1288","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie gazów","parameters":[{"name":"CO","range":"(2,33 - 250) mg/m3 (2 - 215) ppm"},{"name":"NO","range":"(0,25- 12,45) mg/m3 (0,2 - 10) ppm"},{"name":"NO2","range":"(0,38 – 3,05) mg/m3 (0,2 - 1,6) ppm"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie gazów\nZakres:\nCO (2,33 - 250) mg/m3 (2 - 215) ppm\nNO (0,25- 12,45) mg/m3 (0,2 - 10) ppm\nNO2 (0,38 – 3,05) mg/m3 (0,2 - 1,6) ppm\nMetoda elektrochemiczna","reference":"Procedura Badawcza PB-02, wydanie 2 z dnia 24.03.2026 r.","norm_bases":["Procedura Badawcza PB-02, wydanie 2 z dnia 24.03.2026 r."],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie gazów\nZakres:\nCO (2,33 - 250) mg/m3 (2 - 215) ppm\nNO (0,25- 12,45) mg/m3 (0,2 - 10) ppm\nNO2 (0,38 – 3,05) mg/m3 (0,2 - 1,6) ppm\nMetoda elektrochemiczna Procedura Badawcza PB-02, wydanie 2 z dnia 24.03.2026 r. Srodowisko pracy - powietrze Stezenie gazow\nZakres:\nCO (2,33 - 250) mg/m3 (2 - 215) ppm\nNO (0,25- 12,45) mg/m3 (0,2 - 10) ppm\nNO2 (0,38 – 3,05) mg/m3 (0,2 - 1,6) ppm\nMetoda elektrochemiczna Procedura Badawcza PB-02, wydanie 2 z dnia 24.03.2026 r.","categories":["environment"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Gas concentrations","parameters_en":[{"name":"CO","range":"(2,33 - 250) mg/m3 (2 - 215) ppm"},{"name":"NO","range":"(0,25- 12,45) mg/m3 (0,2 - 10) ppm"},{"name":"NO2","range":"(0,38 – 3,05) mg/m3 (0,2 - 1,6) ppm"}],"search_en":"Workplace environment - air Gas concentrations Electrochemical method Laboratory CO NO NO2 Procedura Badawcza PB-02, wydanie 2 z dnia 24.03.2026 r.","technique_en":"Electrochemical method","test_object_en":"Workplace environment - air","lab_section_zh":"实验室","search_zh":"工作场所环境 — 空气 气体浓度 电化学法 实验室 CO NO NO2 Procedura Badawcza PB-02, wydanie 2 z dnia 24.03.2026 r.","technique_zh":"电化学法","test_object_zh":"工作场所环境 — 空气","parameters_zh":[{"name":"CO","range":"(2,33 - 250) mg/m3 (2 - 215) ppm"},{"name":"NO","range":"(0,25- 12,45) mg/m3 (0,2 - 10) ppm"},{"name":"NO2","range":"(0,38 – 3,05) mg/m3 (0,2 - 1,6) ppm"}],"methodology_zh":"气体浓度"},{"_id":"6a82ddfb884ede9a1b2c34e9","lab_id":"69ad52a3de79e566650fb69a","country":"PL","accr_number":"AB 1288","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"Procedura Badawcza PB-02, wydanie 2 z dnia 24.03.2026 r.","norm_bases":["Procedura Badawcza PB-02, wydanie 2 z dnia 24.03.2026 r."],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Wskaźnik narażenia (z obliczeń) Procedura Badawcza PB-02, wydanie 2 z dnia 24.03.2026 r. Srodowisko pracy - powietrze Wskaznik narazenia (z obliczen) Procedura Badawcza PB-02, wydanie 2 z dnia 24.03.2026 r.","categories":["environment"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Exposure index (calculated)","search_en":"Workplace environment - air Exposure index (calculated) Laboratory Procedura Badawcza PB-02, wydanie 2 z dnia 24.03.2026 r.","test_object_en":"Workplace environment - air","lab_section_zh":"实验室","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出） 实验室 Procedura Badawcza PB-02, wydanie 2 z dnia 24.03.2026 r.","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a82ddfb884ede9a1b2c34ea","lab_id":"69ad52a3de79e566650fb69a","country":"PL","accr_number":"AB 1288","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia","parameters":[{"name":"frakcja wdychalna"},{"name":"Asfalt naftowy"},{"name":"Apatyty i fosforyty"},{"name":"Cement portlandzki"},{"name":"Ditlenek tytanu"},{"name":"Grafit naturalny"},{"name":"Grafit syntetyczny"},{"name":"Kaolin"},{"name":"Krzemionka bezpostaciowa i synte-tyczna"},{"name":"Pyły drewna"},{"name":"Pyły mąki"},{"name":"Pyły niesklasyfikowane ze względu na toksyczność"},{"name":"Pyły organiczne pochodzenia zwierzę-cego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Siarczan (VI) wapnia (gips)"},{"name":"Sadza techniczna"},{"name":"Talk"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Węglan magnezu wapnia (dolomit)"},{"name":"Węglik krzemu, niewłóknisty"},{"name":"Zakres","range":"(0,12 – 20,44) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia\nZakres:\nfrakcja wdychalna\nAsfalt naftowy\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i synte-tyczna\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzę-cego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nTalk\nWęgiel (kamienny, brunatny)\nWęglan magnezu wapnia (dolomit)\nWęglik krzemu, niewłóknisty\nZakres (0,12 – 20,44) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05","PN-Z-04507:2022-05/Ap1:2022-08"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia\nZakres:\nfrakcja wdychalna\nAsfalt naftowy\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i synte-tyczna\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzę-cego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nTalk\nWęgiel (kamienny, brunatny)\nWęglan magnezu wapnia (dolomit)\nWęglik krzemu, niewłóknisty\nZakres (0,12 – 20,44) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia\nZakres:\nfrakcja wdychalna\nAsfalt naftowy\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i synte-tyczna\nPyly drewna\nPyly maki\nPyly niesklasyfikowane ze wzgledu na toksycznosc\nPyly organiczne pochodzenia zwierze-cego i roslinnego z wyjatkiem pylow drewna oraz maki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nTalk\nWegiel (kamienny, brunatny)\nWeglan magnezu wapnia (dolomit)\nWeglik krzemu, niewloknisty\nZakres (0,12 – 20,44) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Concentration of harmful dust agents","parameters_en":[{"name":"inhalable fraction"},{"name":"Petroleum bitumen"},{"name":"Apatites and phosphorites"},{"name":"Portland cement"},{"name":"Titanium dioxide"},{"name":"Natural graphite"},{"name":"Synthetic graphite"},{"name":"Kaolin"},{"name":"Amorphous and synthe-tic silica"},{"name":"Wood dusts"},{"name":"Flour dusts"},{"name":"Dusts not classified according to toxicity"},{"name":"Pyły organiczne pochodzenia zwierzę-cego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Calcium sulfate (VI) (gypsum)"},{"name":"Carbon black"},{"name":"Talc"},{"name":"Coal (hard, brown)"},{"name":"Calcium magnesium carbonate (dolomite)"},{"name":"Silicon carbide, non-fibrous"},{"name":"Range","range":"(0,12 – 20,44) mg/m3"}],"search_en":"Workplace environment - air Concentration of harmful dust agents Gravimetric method Laboratory inhalable fraction Petroleum bitumen Apatites and phosphorites Portland cement Titanium dioxide Natural graphite Synthetic graphite Kaolin Amorphous and synthe-tic silica Wood dusts Flour dusts Dusts not classified according to toxicity Calcium sulfate (VI) (gypsum) Carbon black Talc Coal (hard, brown) Calcium magnesium carbonate (dolomite) Silicon carbide, non-fibrous Range PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment - air","lab_section_zh":"实验室","parameters_zh":[{"name":"可吸入组分"},{"name":"石油沥青"},{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"二氧化钛"},{"name":"天然石墨"},{"name":"合成石墨"},{"name":"高岭土"},{"name":"Krzemionka bezpostaciowa i synte-tyczna"},{"name":"木粉尘"},{"name":"面粉粉尘"},{"name":"未按毒性分类的粉尘"},{"name":"Pyły organiczne pochodzenia zwierzę-cego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"硫酸钙（VI）（石膏）"},{"name":"炭黑"},{"name":"滑石"},{"name":"煤（烟煤、褐煤）"},{"name":"碳酸钙镁（白云石）"},{"name":"碳化硅，非纤维状"},{"name":"范围","range":"(0,12 – 20,44) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害健康的粉尘因子浓度 重量法 实验室 可吸入组分 石油沥青 磷灰石与磷块岩 硅酸盐水泥 二氧化钛 天然石墨 合成石墨 高岭土 木粉尘 面粉粉尘 未按毒性分类的粉尘 硫酸钙（VI）（石膏） 炭黑 滑石 煤（烟煤、褐煤） 碳酸钙镁（白云石） 碳化硅，非纤维状 范围 PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害健康的粉尘因子浓度"},{"_id":"6a82ddfb884ede9a1b2c34eb","lab_id":"69ad52a3de79e566650fb69a","country":"PL","accr_number":"AB 1288","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia","parameters":[{"name":"frakcja respirabilna"},{"name":"Apatyty i fosforyty"},{"name":"Cement portlandzki"},{"name":"Grafit naturalny"},{"name":"Krzemionka bezpostaciowa i synte-tyczna"},{"name":"Pyły organiczne pochodzenia zwierzę-cego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Talk"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Zakres","range":"(0,07 – 15,49) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia\nZakres:\nfrakcja respirabilna\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i synte-tyczna\nPyły organiczne pochodzenia zwierzę-cego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nTalk\nWęgiel (kamienny, brunatny)\nZakres (0,07 – 15,49) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04508:2022-05","PN-Z-04508:2022-05/Ap1:2022-08"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia\nZakres:\nfrakcja respirabilna\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i synte-tyczna\nPyły organiczne pochodzenia zwierzę-cego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nTalk\nWęgiel (kamienny, brunatny)\nZakres (0,07 – 15,49) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia\nZakres:\nfrakcja respirabilna\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i synte-tyczna\nPyly organiczne pochodzenia zwierze-cego i roslinnego z wyjatkiem pylow drewna oraz maki\nTalk\nWegiel (kamienny, brunatny)\nZakres (0,07 – 15,49) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Concentration of harmful dust agents","parameters_en":[{"name":"respirable fraction"},{"name":"Apatites and phosphorites"},{"name":"Portland cement"},{"name":"Natural graphite"},{"name":"Amorphous and synthe-tic silica"},{"name":"Pyły organiczne pochodzenia zwierzę-cego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Talc"},{"name":"Coal (hard, brown)"},{"name":"Range","range":"(0,07 – 15,49) mg/m3"}],"search_en":"Workplace environment - air Concentration of harmful dust agents Gravimetric method Laboratory respirable fraction Apatites and phosphorites Portland cement Natural graphite Amorphous and synthe-tic silica Talc Coal (hard, brown) Range PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment - air","lab_section_zh":"实验室","parameters_zh":[{"name":"呼吸性组分"},{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"天然石墨"},{"name":"Krzemionka bezpostaciowa i synte-tyczna"},{"name":"Pyły organiczne pochodzenia zwierzę-cego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"滑石"},{"name":"煤（烟煤、褐煤）"},{"name":"范围","range":"(0,07 – 15,49) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害健康的粉尘因子浓度 重量法 实验室 呼吸性组分 磷灰石与磷块岩 硅酸盐水泥 天然石墨 滑石 煤（烟煤、褐煤） 范围 PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害健康的粉尘因子浓度"},{"_id":"6a82ddfb884ede9a1b2c34ec","lab_id":"69ad52a3de79e566650fb69a","country":"PL","accr_number":"AB 1288","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat gorący","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(10 - 60) °C"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres (10 - 60) °C\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7243:2018-01+Ap2:2020-04","norm_bases":["PN-EN ISO 7243:2018-01+Ap2:2020-04"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat gorący Temperatura powietrza\nZakres (10 - 60) °C\nMetoda pomiarowa bezpośrednia PN-EN ISO 7243:2018-01+Ap2:2020-04 Srodowisko pracy - mikroklimat goracy Temperatura powietrza\nZakres (10 - 60) °C\nMetoda pomiarowa bezposrednia PN-EN ISO 7243:2018-01+Ap2:2020-04","categories":["environment"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(10 - 60) °C"}],"search_en":"Workplace environment - hot microclimate Air temperature Direct measurement method Laboratory Range PN-EN ISO 7243:2018-01+Ap2:2020-04","technique_en":"Direct measurement method","test_object_en":"Workplace environment - hot microclimate","lab_section_zh":"实验室","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(10 - 60) °C"}],"search_zh":"工作场所环境 — 高温微气候 空气温度 直接测量法 实验室 范围 PN-EN ISO 7243:2018-01+Ap2:2020-04","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 高温微气候"},{"_id":"6a82ddfb884ede9a1b2c34ed","lab_id":"69ad52a3de79e566650fb69a","country":"PL","accr_number":"AB 1288","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat gorący","methodology":"Temperatura wilgotna naturalna","parameters":[{"name":"Zakres","range":"(5 - 60) °C"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura wilgotna naturalna\nZakres (5 - 60) °C\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7243:2018-01+Ap2:2020-04","norm_bases":["PN-EN ISO 7243:2018-01+Ap2:2020-04"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat gorący Temperatura wilgotna naturalna\nZakres (5 - 60) °C\nMetoda pomiarowa bezpośrednia PN-EN ISO 7243:2018-01+Ap2:2020-04 Srodowisko pracy - mikroklimat goracy Temperatura wilgotna naturalna\nZakres (5 - 60) °C\nMetoda pomiarowa bezposrednia PN-EN ISO 7243:2018-01+Ap2:2020-04","categories":["environment"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Natural wet bulb temperature","parameters_en":[{"name":"Range","range":"(5 - 60) °C"}],"search_en":"Workplace environment - hot microclimate Natural wet bulb temperature Direct measurement method Laboratory Range PN-EN ISO 7243:2018-01+Ap2:2020-04","technique_en":"Direct measurement method","test_object_en":"Workplace environment - hot microclimate","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(5 - 60) °C"}],"search_zh":"工作场所环境 — 高温微气候 自然湿球温度 直接测量法 实验室 范围 PN-EN ISO 7243:2018-01+Ap2:2020-04","technique_zh":"直接测量法","methodology_zh":"自然湿球温度","test_object_zh":"工作场所环境 — 高温微气候"},{"_id":"6a82ddfb884ede9a1b2c34ee","lab_id":"69ad52a3de79e566650fb69a","country":"PL","accr_number":"AB 1288","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat gorący","methodology":"Temperatura poczernionej kuli","parameters":[{"name":"Zakres","range":"(10 - 60) °C"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura poczernionej kuli\nZakres (10 - 60) °C\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7243:2018-01+Ap2:2020-04","norm_bases":["PN-EN ISO 7243:2018-01+Ap2:2020-04"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat gorący Temperatura poczernionej kuli\nZakres (10 - 60) °C\nMetoda pomiarowa bezpośrednia PN-EN ISO 7243:2018-01+Ap2:2020-04 Srodowisko pracy - mikroklimat goracy Temperatura poczernionej kuli\nZakres (10 - 60) °C\nMetoda pomiarowa bezposrednia PN-EN ISO 7243:2018-01+Ap2:2020-04","categories":["environment"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Black globe temperature","parameters_en":[{"name":"Range","range":"(10 - 60) °C"}],"search_en":"Workplace environment - hot microclimate Black globe temperature Direct measurement method Laboratory Range PN-EN ISO 7243:2018-01+Ap2:2020-04","technique_en":"Direct measurement method","test_object_en":"Workplace environment - hot microclimate","lab_section_zh":"实验室","methodology_zh":"黑球温度","parameters_zh":[{"name":"范围","range":"(10 - 60) °C"}],"search_zh":"工作场所环境 — 高温微气候 黑球温度 直接测量法 实验室 范围 PN-EN ISO 7243:2018-01+Ap2:2020-04","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 高温微气候"},{"_id":"6a82ddfb884ede9a1b2c34ef","lab_id":"69ad52a3de79e566650fb69a","country":"PL","accr_number":"AB 1288","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat gorący","methodology":"Wskaźnik WBGT (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik WBGT (z obliczeń)","reference":"PN-EN ISO 7243:2018-01+Ap2:2020-04","norm_bases":["PN-EN ISO 7243:2018-01+Ap2:2020-04"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat gorący Wskaźnik WBGT (z obliczeń) PN-EN ISO 7243:2018-01+Ap2:2020-04 Srodowisko pracy - mikroklimat goracy Wskaznik WBGT (z obliczen) PN-EN ISO 7243:2018-01+Ap2:2020-04","categories":["environment"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"WBGT index (calculated)","search_en":"Workplace environment - hot microclimate WBGT index (calculated) Laboratory PN-EN ISO 7243:2018-01+Ap2:2020-04","test_object_en":"Workplace environment - hot microclimate","lab_section_zh":"实验室","search_zh":"工作场所环境 — 高温微气候 WBGT 指数（由计算得出） 实验室 PN-EN ISO 7243:2018-01+Ap2:2020-04","test_object_zh":"工作场所环境 — 高温微气候","methodology_zh":"WBGT 指数（由计算得出）"},{"_id":"6a82ddfb884ede9a1b2c34f0","lab_id":"69ad52a3de79e566650fb69a","country":"PL","accr_number":"AB 1288","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat gorący","methodology":"Wskaźnik WBGTeff (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik WBGTeff (z obliczeń)","reference":"PN-EN ISO 7243:2018-01+Ap2:2020-04","norm_bases":["PN-EN ISO 7243:2018-01+Ap2:2020-04"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat gorący Wskaźnik WBGTeff (z obliczeń) PN-EN ISO 7243:2018-01+Ap2:2020-04 Srodowisko pracy - mikroklimat goracy Wskaznik WBGTeff (z obliczen) PN-EN ISO 7243:2018-01+Ap2:2020-04","categories":["environment"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"WBGTeff index (calculated)","search_en":"Workplace environment - hot microclimate WBGTeff index (calculated) Laboratory PN-EN ISO 7243:2018-01+Ap2:2020-04","test_object_en":"Workplace environment - hot microclimate","lab_section_zh":"实验室","search_zh":"工作场所环境 — 高温微气候 WBGTeff 指数（由计算得出） 实验室 PN-EN ISO 7243:2018-01+Ap2:2020-04","test_object_zh":"工作场所环境 — 高温微气候","methodology_zh":"WBGTeff 指数（由计算得出）"},{"_id":"6a82ddfb884ede9a1b2c34f1","lab_id":"69ad52a3de79e566650fb69a","country":"PL","accr_number":"AB 1288","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat zimny","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(-30 - 10) °C"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres (-30 - 10) °C\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat zimny Temperatura powietrza\nZakres (-30 - 10) °C\nMetoda pomiarowa bezpośrednia PN-EN ISO 11079:2008 Srodowisko pracy - mikroklimat zimny Temperatura powietrza\nZakres (-30 - 10) °C\nMetoda pomiarowa bezposrednia PN-EN ISO 11079:2008","categories":["environment"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(-30 - 10) °C"}],"search_en":"Workplace environment - cold microclimate Air temperature Direct measurement method Laboratory Range PN-EN ISO 11079:2008","technique_en":"Direct measurement method","test_object_en":"Workplace environment - cold microclimate","lab_section_zh":"实验室","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(-30 - 10) °C"}],"search_zh":"工作场所环境 — 低温微气候 空气温度 直接测量法 实验室 范围 PN-EN ISO 11079:2008","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 低温微气候"},{"_id":"6a82ddfb884ede9a1b2c34f2","lab_id":"69ad52a3de79e566650fb69a","country":"PL","accr_number":"AB 1288","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat zimny","methodology":"Temperatura poczernionej kuli","parameters":[{"name":"Zakres","range":"(-30 - 10) °C"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura poczernionej kuli\nZakres (-30 - 10) °C\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat zimny Temperatura poczernionej kuli\nZakres (-30 - 10) °C\nMetoda pomiarowa bezpośrednia PN-EN ISO 11079:2008 Srodowisko pracy - mikroklimat zimny Temperatura poczernionej kuli\nZakres (-30 - 10) °C\nMetoda pomiarowa bezposrednia PN-EN ISO 11079:2008","categories":["environment"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Black globe temperature","parameters_en":[{"name":"Range","range":"(-30 - 10) °C"}],"search_en":"Workplace environment - cold microclimate Black globe temperature Direct measurement method Laboratory Range PN-EN ISO 11079:2008","technique_en":"Direct measurement method","test_object_en":"Workplace environment - cold microclimate","lab_section_zh":"实验室","methodology_zh":"黑球温度","parameters_zh":[{"name":"范围","range":"(-30 - 10) °C"}],"search_zh":"工作场所环境 — 低温微气候 黑球温度 直接测量法 实验室 范围 PN-EN ISO 11079:2008","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 低温微气候"},{"_id":"6a82ddfb884ede9a1b2c34f3","lab_id":"69ad52a3de79e566650fb69a","country":"PL","accr_number":"AB 1288","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat zimny","methodology":"Wilgotność powietrza","parameters":[{"name":"Zakres","range":"(20 - 90) %"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Wilgotność powietrza\nZakres (20 - 90) %\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat zimny Wilgotność powietrza\nZakres (20 - 90) %\nMetoda pomiarowa bezpośrednia PN-EN ISO 11079:2008 Srodowisko pracy - mikroklimat zimny Wilgotnosc powietrza\nZakres (20 - 90) %\nMetoda pomiarowa bezposrednia PN-EN ISO 11079:2008","categories":["environment"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Air humidity","parameters_en":[{"name":"Range","range":"(20 - 90) %"}],"search_en":"Workplace environment - cold microclimate Air humidity Direct measurement method Laboratory Range PN-EN ISO 11079:2008","technique_en":"Direct measurement method","test_object_en":"Workplace environment - cold microclimate","lab_section_zh":"实验室","methodology_zh":"空气湿度","parameters_zh":[{"name":"范围","range":"(20 - 90) %"}],"search_zh":"工作场所环境 — 低温微气候 空气湿度 直接测量法 实验室 范围 PN-EN ISO 11079:2008","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 低温微气候"},{"_id":"6a82ddfb884ede9a1b2c34f4","lab_id":"69ad52a3de79e566650fb69a","country":"PL","accr_number":"AB 1288","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat zimny","methodology":"Prędkość powietrza","parameters":[{"name":"Zakres","range":"(0,15 - 5) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Prędkość powietrza\nZakres (0,15 - 5) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat zimny Prędkość powietrza\nZakres (0,15 - 5) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 11079:2008 Srodowisko pracy - mikroklimat zimny Predkosc powietrza\nZakres (0,15 - 5) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 11079:2008","categories":["environment"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Air velocity","parameters_en":[{"name":"Range","range":"(0,15 - 5) m/s"}],"search_en":"Workplace environment - cold microclimate Air velocity Direct measurement method Laboratory Range PN-EN ISO 11079:2008","technique_en":"Direct measurement method","test_object_en":"Workplace environment - cold microclimate","lab_section_zh":"实验室","methodology_zh":"空气流速","parameters_zh":[{"name":"范围","range":"(0,15 - 5) m/s"}],"search_zh":"工作场所环境 — 低温微气候 空气流速 直接测量法 实验室 范围 PN-EN ISO 11079:2008","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 低温微气候"},{"_id":"6a82ddfb884ede9a1b2c34f5","lab_id":"69ad52a3de79e566650fb69a","country":"PL","accr_number":"AB 1288","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat zimny","methodology":"Wskaźnik IREQmin (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik IREQmin (z obliczeń)","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat zimny Wskaźnik IREQmin (z obliczeń) PN-EN ISO 11079:2008 Srodowisko pracy - mikroklimat zimny Wskaznik IREQmin (z obliczen) PN-EN ISO 11079:2008","categories":["environment"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","search_en":"Workplace environment - cold microclimate Laboratory PN-EN ISO 11079:2008","test_object_en":"Workplace environment - cold microclimate","lab_section_zh":"实验室","search_zh":"工作场所环境 — 低温微气候 实验室 PN-EN ISO 11079:2008","test_object_zh":"工作场所环境 — 低温微气候"},{"_id":"6a82ddfb884ede9a1b2c34f6","lab_id":"69ad52a3de79e566650fb69a","country":"PL","accr_number":"AB 1288","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat zimny","methodology":"Wskaźnik IREQneutral (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik IREQneutral (z obliczeń)","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat zimny Wskaźnik IREQneutral (z obliczeń) PN-EN ISO 11079:2008 Srodowisko pracy - mikroklimat zimny Wskaznik IREQneutral (z obliczen) PN-EN ISO 11079:2008","categories":["environment"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"IREQneutral index (calculated)","search_en":"Workplace environment - cold microclimate IREQneutral index (calculated) Laboratory PN-EN ISO 11079:2008","test_object_en":"Workplace environment - cold microclimate","lab_section_zh":"实验室","search_zh":"工作场所环境 — 低温微气候 实验室 PN-EN ISO 11079:2008","test_object_zh":"工作场所环境 — 低温微气候"},{"_id":"6a82ddfb884ede9a1b2c34f7","lab_id":"69ad52a3de79e566650fb69a","country":"PL","accr_number":"AB 1288","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat zimny","methodology":"Wskaźnik tWC (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik tWC (z obliczeń)","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat zimny Wskaźnik tWC (z obliczeń) PN-EN ISO 11079:2008 Srodowisko pracy - mikroklimat zimny Wskaznik tWC (z obliczen) PN-EN ISO 11079:2008","categories":["environment"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","search_en":"Workplace environment - cold microclimate Laboratory PN-EN ISO 11079:2008","test_object_en":"Workplace environment - cold microclimate","lab_section_zh":"实验室","search_zh":"工作场所环境 — 低温微气候 实验室 PN-EN ISO 11079:2008","test_object_zh":"工作场所环境 — 低温微气候"},{"_id":"6a82ddfb884ede9a1b2c34f8","lab_id":"69ad52a3de79e566650fb69a","country":"PL","accr_number":"AB 1288","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat umiarkowany","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(10 - 30) °C"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres (10 - 30) °C\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7730:2006+Ap2:2016-04","norm_bases":["PN-EN ISO 7730:2006+Ap2:2016-04"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat umiarkowany Temperatura powietrza\nZakres (10 - 30) °C\nMetoda pomiarowa bezpośrednia PN-EN ISO 7730:2006+Ap2:2016-04 Srodowisko pracy - mikroklimat umiarkowany Temperatura powietrza\nZakres (10 - 30) °C\nMetoda pomiarowa bezposrednia PN-EN ISO 7730:2006+Ap2:2016-04","categories":["environment"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(10 - 30) °C"}],"search_en":"Workplace environment - moderate microclimate Air temperature Direct measurement method Laboratory Range PN-EN ISO 7730:2006+Ap2:2016-04","technique_en":"Direct measurement method","test_object_en":"Workplace environment - moderate microclimate","lab_section_zh":"实验室","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(10 - 30) °C"}],"search_zh":"工作场所环境 — 中等微气候 空气温度 直接测量法 实验室 范围 PN-EN ISO 7730:2006+Ap2:2016-04","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 中等微气候"},{"_id":"6a82ddfb884ede9a1b2c34f9","lab_id":"69ad52a3de79e566650fb69a","country":"PL","accr_number":"AB 1288","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat umiarkowany","methodology":"Temperatura poczernionej kuli","parameters":[{"name":"Zakres","range":"(10 - 40) °C"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura poczernionej kuli\nZakres (10 - 40) °C\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7730:2006+Ap2:2016-04","norm_bases":["PN-EN ISO 7730:2006+Ap2:2016-04"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat umiarkowany Temperatura poczernionej kuli\nZakres (10 - 40) °C\nMetoda pomiarowa bezpośrednia PN-EN ISO 7730:2006+Ap2:2016-04 Srodowisko pracy - mikroklimat umiarkowany Temperatura poczernionej kuli\nZakres (10 - 40) °C\nMetoda pomiarowa bezposrednia PN-EN ISO 7730:2006+Ap2:2016-04","categories":["environment"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Black globe temperature","parameters_en":[{"name":"Range","range":"(10 - 40) °C"}],"search_en":"Workplace environment - moderate microclimate Black globe temperature Direct measurement method Laboratory Range PN-EN ISO 7730:2006+Ap2:2016-04","technique_en":"Direct measurement method","test_object_en":"Workplace environment - moderate microclimate","lab_section_zh":"实验室","methodology_zh":"黑球温度","parameters_zh":[{"name":"范围","range":"(10 - 40) °C"}],"search_zh":"工作场所环境 — 中等微气候 黑球温度 直接测量法 实验室 范围 PN-EN ISO 7730:2006+Ap2:2016-04","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 中等微气候"},{"_id":"6a82ddfb884ede9a1b2c34fa","lab_id":"69ad52a3de79e566650fb69a","country":"PL","accr_number":"AB 1288","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat umiarkowany","methodology":"Wilgotność powietrza","parameters":[{"name":"Zakres","range":"(20 - 90) %"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Wilgotność powietrza\nZakres (20 - 90) %\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7730:2006+Ap2:2016-04","norm_bases":["PN-EN ISO 7730:2006+Ap2:2016-04"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat umiarkowany Wilgotność powietrza\nZakres (20 - 90) %\nMetoda pomiarowa bezpośrednia PN-EN ISO 7730:2006+Ap2:2016-04 Srodowisko pracy - mikroklimat umiarkowany Wilgotnosc powietrza\nZakres (20 - 90) %\nMetoda pomiarowa bezposrednia PN-EN ISO 7730:2006+Ap2:2016-04","categories":["environment"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Air humidity","parameters_en":[{"name":"Range","range":"(20 - 90) %"}],"search_en":"Workplace environment - moderate microclimate Air humidity Direct measurement method Laboratory Range PN-EN ISO 7730:2006+Ap2:2016-04","technique_en":"Direct measurement method","test_object_en":"Workplace environment - moderate microclimate","lab_section_zh":"实验室","methodology_zh":"空气湿度","parameters_zh":[{"name":"范围","range":"(20 - 90) %"}],"search_zh":"工作场所环境 — 中等微气候 空气湿度 直接测量法 实验室 范围 PN-EN ISO 7730:2006+Ap2:2016-04","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 中等微气候"},{"_id":"6a82ddfb884ede9a1b2c34fb","lab_id":"69ad52a3de79e566650fb69a","country":"PL","accr_number":"AB 1288","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat umiarkowany","methodology":"Prędkość powietrza","parameters":[{"name":"Zakres","range":"(0,15 - 1) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Prędkość powietrza\nZakres (0,15 - 1) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7730:2006+Ap2:2016-04","norm_bases":["PN-EN ISO 7730:2006+Ap2:2016-04"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat umiarkowany Prędkość powietrza\nZakres (0,15 - 1) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 7730:2006+Ap2:2016-04 Srodowisko pracy - mikroklimat umiarkowany Predkosc powietrza\nZakres (0,15 - 1) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 7730:2006+Ap2:2016-04","categories":["environment"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Air velocity","parameters_en":[{"name":"Range","range":"(0,15 - 1) m/s"}],"search_en":"Workplace environment - moderate microclimate Air velocity Direct measurement method Laboratory Range PN-EN ISO 7730:2006+Ap2:2016-04","technique_en":"Direct measurement method","test_object_en":"Workplace environment - moderate microclimate","lab_section_zh":"实验室","methodology_zh":"空气流速","parameters_zh":[{"name":"范围","range":"(0,15 - 1) m/s"}],"search_zh":"工作场所环境 — 中等微气候 空气流速 直接测量法 实验室 范围 PN-EN ISO 7730:2006+Ap2:2016-04","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 中等微气候"},{"_id":"6a82ddfb884ede9a1b2c34fc","lab_id":"69ad52a3de79e566650fb69a","country":"PL","accr_number":"AB 1288","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat umiarkowany","methodology":"Wskaźnik PMV (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik PMV (z obliczeń)","reference":"PN-EN ISO 7730:2006+Ap2:2016-04","norm_bases":["PN-EN ISO 7730:2006+Ap2:2016-04"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat umiarkowany Wskaźnik PMV (z obliczeń) PN-EN ISO 7730:2006+Ap2:2016-04 Srodowisko pracy - mikroklimat umiarkowany Wskaznik PMV (z obliczen) PN-EN ISO 7730:2006+Ap2:2016-04","categories":["environment"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","search_en":"Workplace environment - moderate microclimate Laboratory PN-EN ISO 7730:2006+Ap2:2016-04","test_object_en":"Workplace environment - moderate microclimate","lab_section_zh":"实验室","search_zh":"工作场所环境 — 中等微气候 实验室 PN-EN ISO 7730:2006+Ap2:2016-04","test_object_zh":"工作场所环境 — 中等微气候"},{"_id":"6a82ddfb884ede9a1b2c34fd","lab_id":"69ad52a3de79e566650fb69a","country":"PL","accr_number":"AB 1288","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat umiarkowany","methodology":"Wskaźnik PPD (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik PPD (z obliczeń)","reference":"PN-EN ISO 7730:2006+Ap2:2016-04","norm_bases":["PN-EN ISO 7730:2006+Ap2:2016-04"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat umiarkowany Wskaźnik PPD (z obliczeń) PN-EN ISO 7730:2006+Ap2:2016-04 Srodowisko pracy - mikroklimat umiarkowany Wskaznik PPD (z obliczen) PN-EN ISO 7730:2006+Ap2:2016-04","categories":["environment"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"PPD index (calculated)","search_en":"Workplace environment - moderate microclimate PPD index (calculated) Laboratory PN-EN ISO 7730:2006+Ap2:2016-04","test_object_en":"Workplace environment - moderate microclimate","lab_section_zh":"实验室","search_zh":"工作场所环境 — 中等微气候 实验室 PN-EN ISO 7730:2006+Ap2:2016-04","test_object_zh":"工作场所环境 — 中等微气候"}],"has_pdf":true}