🇵🇱 GDAŃSKA STOCZNIA „REMONTOWA” PL

PCA AB 1285 • Gdańsk, Poland • 24 methods

EnvironmentWater & wastewaterMaterials & polymersConstruction

GDAŃSKA STOCZNIA „REMONTOWA” is a laboratory accredited by PCA under number AB 1285 (Gdańsk, Poland). Its accreditation scope covers 24 test methods in the following areas: Environment, Water & wastewater, Materials & polymers, Construction. Test objects include: Workplace environment - air, Wastewater, Water and wastewater, Workplace environment - hand-arm vibration. Most frequently used techniques: Flame atomic absorption spectrometry (FAAS), Direct measurement method, Gravimetric method.

At a glance

  • Accreditation number: PCA AB 1285
  • Methods in scope: 24
  • Types of test objects: 7
  • Techniques used: 8
  • City: Gdańsk, Poland
Accreditation number
AB 1285
Accreditation body
PCA
Address
im. J. Piłsudskiego S.A., Zespół ds. Ochrony Środowiska, ul. Na Ostrowiu 1, 80-958 Gdańsk
City
Gdańsk, Poland

What this laboratory tests (7)

Analytical techniques used (8)

Laboratory locations

Accreditation scope — test methods (24)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Workplace environment - air Sampling for the assessment of occupational exposure to:
dust agents inhalable fraction respirable fraction
Personal dosimetry method PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004
2 Workplace environment - air Sampling for the assessment of occupational exposure to:
metals and their compounds, including inhalable fraction respirable fraction inorganic substances respirable fraction respirable asbestos fibres respirable man-made mineral fibres excluding refractory ceramic fibres refractory ceramic fibres refractory ceramic fibres mixed with other man-made mineral fibres
Personal dosimetry method PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004
3 Workplace environment - air Exposure index (calculated) PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004
4 Workplace environment - air Concentration of harmful dust agents – inhalable fraction
apatites and phosphorites portland cement titanium dioxide kaolin amorphous and synthetic silica wood dusts flour dusts dusts not classified according to toxicity organic dusts of animal and plant origin, excluding wood and flour dusts calcium sulfate (VI) (gypsum) carbon black coal (hard, brown) Range (0,19 – 34,72) mg/m3
Gravimetric method PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08
5 Workplace environment - air Concentration of harmful dust agents – respirable fraction
apatites and phosphorites portland cement amorphous and synthetic silica organic dusts of animal and plant origin, excluding wood and flour dusts coal (hard, brown) Range (0,10 – 18,94) mg/m3
Gravimetric method PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08
6 Workplace environment - air Carbon monoxide concentration
Range (2,3 – 234) mg/m3 Range (2 – 200) ppm
Electrochemical method PB-8 ed. 2 z dn. 18.08.2025 r.
7 Workplace environment - air Exposure indices (calculated) PB-8 ed. 2 z dn. 18.08.2025 r.
8 Workplace environment - air Concentration/content of manganese and its inorganic compounds calculated as Mn – inhalable fraction
Range (0,017-0,417) mg/m3 Range (0,012-0,300) mg w próbce – respirable fraction Range (0,004 - 0,379) mg/m3 Range (0,003 - 0,300) mg w próbce
Flame atomic absorption spectrometry (FAAS) PN-Z-04472:2015-10+Ap1:2015-12
9 Workplace environment - air Concentration/content of iron oxides calculated as Fe iron(III) oxide iron(II) oxide triiron tetraoxide
inhalable fraction Range (0,347 – 125) mg/m3 Range (0,05 – 15) mg w próbce respirable fraction Range (0,158 – 56,82) mg/m3 Range (0,05 – 7,50) mg w próbce
Flame atomic absorption spectrometry (FAAS) PN-Z-04469:2025-02
10 Workplace environment - lighting Illuminance
Range (5 – 5000) lx
Direct measurement method PN-83/E-04040.03 | PB-3 ed. 5 z dn. 21.05.2021r.
11 Workplace environment - lighting Illuminance uniformity (calculated) PN-83/E-04040.03 | PB-3 ed. 5 z dn. 21.05.2021r.
12 Workplace environment - noise A-weighted equivalent sound level Maximum A-weighted sound level
Range (40 – 130) dB C-weighted peak sound pressure level Range (55 – 136) dB
Direct measurement method PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i Strategię 3 – punkt 10 i punkt 11
13 Workplace environment - noise Noise exposure level referred to:
an 8-hour daily working time the average weekly working time (calculated)
PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i Strategię 3 – punkt 10 i punkt 11
14 Workplace environment - hand-arm vibration Frequency-weighted r.m.s. vibration acceleration
Range (0,32 – 100) m/s2
Direct measurement method PN-EN-ISO 5349-1:2004 | PN-EN-ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11
15 Workplace environment - hand-arm vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated) PN-EN-ISO 5349-1:2004 | PN-EN-ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11
16 Workplace environment - whole-body vibration Frequency-weighted r.m.s. vibration acceleration
Range (0,08 – 25) m/s2
Direct measurement method PN-EN 14253+A1:2011
17 Workplace environment - whole-body vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated) PN-EN 14253+A1:2011
18 Wastewater Sampling for chemical and physical testing Manual method PN-ISO 5667-10:2021-11
19 Wastewater pH
Range 4,0 – 10,0
Potentiometric method PN-EN ISO 10523:2012
20 Wastewater Total suspended solids (TSS)
Range (5,0 – 125) mg/l
Gravimetric method PN-EN 872:2007 + Ap1:2007
21 Wastewater Chemical oxygen demand – COD
Range (10,0 – 150) mg/I O2
Spectrophotometric method PN-ISO 15705:2005
22 Wastewater Chromium concentration
Range (0,250 – 2,00) mg/I
Flame atomic absorption spectrometry (FAAS) PB-06 ed. 2 z dn. 01.08.2024 r.
23 Water and wastewater Metal concentrations
iron (0,2 – 20,0) mg/l
Flame atomic absorption spectrometry (FAAS) PB-04 ed. 3 z dn. 01.08.2024 r.
24 Water and wastewater Metal concentrations
zinc (0,05 – 4,0) mg/l copper (0,05 – 6,0) mg/l nickel (0,2 – 10,0) mg/l lead (0,2 – 10,0) mg/l
Flame atomic absorption spectrometry (FAAS) PN-ISO 8288:2002

Reference standards (24)

PB-04 ed. 3 z dn. 01.08.2024 r.
PB-06 ed. 2 z dn. 01.08.2024 r.
PB-3 ed. 5 z dn. 21.05.2021r.
PB-8 ed. 2 z dn. 18.08.2025 r.
PN-83/E-04040.03
PN-EN 14253+A1:2011
PN-EN 872:2007 + Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 5349-2:2004/A1:2015-11
PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i Strategię 3 – punkt 10 i punkt 11
PN-EN-ISO 5349-1:2004
PN-EN-ISO 5349-2:2004
PN-ISO 15705:2005
PN-ISO 5667-10:2021-11
PN-ISO 8288:2002
PN-N-01307:1994
PN-Z-04008-7:2002
PN-Z-04008-7:2002/Az1:2004
PN-Z-04469:2025-02
PN-Z-04472:2015-10+Ap1:2015-12
PN-Z-04507:2022-05
PN-Z-04507:2022-05/Ap1:2022-08
PN-Z-04508:2022-05
PN-Z-04508:2022-05/Ap1:2022-08