{"lab":{"_id":"69ad52a3de79e566650fb694","accr_number":"AB 1285","country":"PL","accr_body":"PCA","address":"im. J. Piłsudskiego S.A., Zespół ds. Ochrony Środowiska, ul. Na Ostrowiu 1, 80-958 Gdańsk","categories":["environment","water","materials","construction"],"city":"Gdańsk","imported_at":"2026-03-08T10:42:43.265Z","methods_count":24,"name":"GDAŃSKA STOCZNIA „REMONTOWA”","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1285.pdf"],"scope_summary":"","search_text":"gdańska stocznia „remontowa” im. j. piłsudskiego s.a., zespół ds. ochrony środowiska, ul. na ostrowiu 1, 80-958 gdańsk environment other water materials","status":"active","updated_at":"2026-03-08T14:50:28.035Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T07:59:27.104Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201285,podmiot.html","parse_date":"2026-08-13T07:59:27.104Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"C/33/P, C/30/P","pl":"Badania chemiczne i pobieranie próbek – środowisko pracy (czynniki szkodliwe – powietrze), ścieki","en":"Chemical tests and sampling – working environment (harmful factors – air), sewage"},{"codes":"C/28","pl":"Badania chemiczne wody","en":"Chemical tests of water"},{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe i uciążliwe – hałas, oświetlenie, drgania)","en":"Tests concerning environmental engineering (environmental and climatic) - working environment (harmful and noisance factors noise, lighting, vibration)"},{"codes":"N/33/P, N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek - środowisko pracy (czynniki szkodliwe – powietrze), ścieki","en":"Tests of physical properties and sampling – working environment (harmful factors – air), sewage"},{"codes":"P/33","pl":"Pobieranie próbek powietrza","en":"Sampling of air"}],"issue":{"no":"23","date":"24.07.2026"},"map_coord":[54.371325,18.653877],"map_geo":"nominatim-street","lab_locations":[{"name":"Zespół ds. Ochrony Środowiska","address":"ul. Na Ostrowiu 1","city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/b44f6ca1b9f2a5b6f90bc38336007e53/AB%201285.pdf","has_en":true,"category_counts":{"environment":17,"water":7,"materials":3,"construction":2},"category_scores":{"environment":9.97,"water":1.69,"materials":0.31,"construction":0.14},"has_zh":true},"methods":[{"_id":"6a7d795f0636ba417e41a962","lab_id":"69ad52a3de79e566650fb694","country":"PL","accr_number":"AB 1285","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","parameters":[{"name":"czynniki pyłowe"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe\nfrakcja wdychalna\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","norm_bases":["PN-Z-04008-7:2002","PN-Z-04008-7:2002/Az1:2004"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe\nfrakcja wdychalna\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004 Srodowisko pracy - powietrze Pobieranie probek do oceny narazenia zawodowego na:\nZakres:\nczynniki pylowe\nfrakcja wdychalna\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","categories":["environment"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"dust agents"},{"name":"inhalable fraction"},{"name":"respirable fraction"}],"search_en":"Workplace environment - air Sampling for the assessment of occupational exposure to: Personal dosimetry method dust agents inhalable fraction respirable fraction PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","technique_en":"Personal dosimetry method","test_object_en":"Workplace environment - air","methodology_zh":"职业接触评估采样，针对：","parameters_zh":[{"name":"粉尘因素"},{"name":"可吸入组分"},{"name":"呼吸性组分"}],"search_zh":"工作场所环境 — 空气 职业接触评估采样，针对： 个体剂量测定法 粉尘因素 可吸入组分 呼吸性组分 PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","technique_zh":"个体剂量测定法","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a7d795f0636ba417e41a963","lab_id":"69ad52a3de79e566650fb694","country":"PL","accr_number":"AB 1285","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","parameters":[{"name":"metale i ich związki, w tym"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"},{"name":"substancje nieorganiczne"},{"name":"frakcja respirabilna"},{"name":"respirabilne włókna azbestu"},{"name":"respirabilne sztuczne włókna mineralne z wyjątkiem ogniotrwałych włókien ceramicznych"},{"name":"ogniotrwałe włókna ceramiczne"},{"name":"ogniotrwałe włókna ceramiczne w mieszaninie z innymi sztucznymi włóknami mineralnymi"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nmetale i ich związki, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje nieorganiczne\nfrakcja respirabilna\nrespirabilne włókna azbestu\nrespirabilne sztuczne włókna mineralne z wyjątkiem ogniotrwałych włókien ceramicznych\nogniotrwałe włókna ceramiczne\nogniotrwałe włókna ceramiczne w mieszaninie z innymi sztucznymi włóknami mineralnymi\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","norm_bases":["PN-Z-04008-7:2002","PN-Z-04008-7:2002/Az1:2004"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nmetale i ich związki, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje nieorganiczne\nfrakcja respirabilna\nrespirabilne włókna azbestu\nrespirabilne sztuczne włókna mineralne z wyjątkiem ogniotrwałych włókien ceramicznych\nogniotrwałe włókna ceramiczne\nogniotrwałe włókna ceramiczne w mieszaninie z innymi sztucznymi włóknami mineralnymi\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004 Srodowisko pracy - powietrze Pobieranie probek do oceny narazenia zawodowego na:\nZakres:\nmetale i ich zwiazki, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje nieorganiczne\nfrakcja respirabilna\nrespirabilne wlokna azbestu\nrespirabilne sztuczne wlokna mineralne z wyjatkiem ogniotrwalych wlokien ceramicznych\nogniotrwale wlokna ceramiczne\nogniotrwale wlokna ceramiczne w mieszaninie z innymi sztucznymi wloknami mineralnymi\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","categories":["materials","environment"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"metals and their compounds, including"},{"name":"inhalable fraction"},{"name":"respirable fraction"},{"name":"inorganic substances"},{"name":"respirable fraction"},{"name":"respirable asbestos fibres"},{"name":"respirable man-made mineral fibres excluding refractory ceramic fibres"},{"name":"refractory ceramic fibres"},{"name":"refractory ceramic fibres mixed with other man-made mineral fibres"}],"search_en":"Workplace environment - air Sampling for the assessment of occupational exposure to: Personal dosimetry method metals and their compounds, including inhalable fraction respirable fraction inorganic substances respirable fraction respirable asbestos fibres respirable man-made mineral fibres excluding refractory ceramic fibres refractory ceramic fibres refractory ceramic fibres mixed with other man-made mineral fibres PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","technique_en":"Personal dosimetry method","test_object_en":"Workplace environment - air","methodology_zh":"职业接触评估采样，针对：","parameters_zh":[{"name":"金属及其化合物，包括"},{"name":"可吸入组分"},{"name":"呼吸性组分"},{"name":"无机物质"},{"name":"呼吸性组分"},{"name":"可吸入石棉纤维"},{"name":"呼吸性人造矿物纤维，耐火陶瓷纤维除外"},{"name":"耐火陶瓷纤维"},{"name":"与其他人造矿物纤维混合的耐火陶瓷纤维"}],"search_zh":"工作场所环境 — 空气 职业接触评估采样，针对： 个体剂量测定法 金属及其化合物，包括 可吸入组分 呼吸性组分 无机物质 呼吸性组分 可吸入石棉纤维 呼吸性人造矿物纤维，耐火陶瓷纤维除外 耐火陶瓷纤维 与其他人造矿物纤维混合的耐火陶瓷纤维 PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","technique_zh":"个体剂量测定法","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a7d795f0636ba417e41a964","lab_id":"69ad52a3de79e566650fb694","country":"PL","accr_number":"AB 1285","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","norm_bases":["PN-Z-04008-7:2002","PN-Z-04008-7:2002/Az1:2004"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004 Srodowisko pracy - powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","categories":["environment"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Exposure index (calculated)","search_en":"Workplace environment - air Exposure index (calculated) PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","test_object_en":"Workplace environment - air","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出） PN-Z-04008-7:2002 | PN-Z-04008-7:2002/Az1:2004","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a7d795f0636ba417e41a965","lab_id":"69ad52a3de79e566650fb694","country":"PL","accr_number":"AB 1285","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna","parameters":[{"name":"apatyty i fosforyty"},{"name":"cement portlandzki"},{"name":"ditlenek tytanu"},{"name":"kaolin"},{"name":"krzemionka bezpostaciowa i syntetyczna"},{"name":"pyły drewna"},{"name":"pyły mąki"},{"name":"pyły niesklasyfikowane ze względu na toksyczność"},{"name":"pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"siarczan (VI) wapnia (gips)"},{"name":"sadza techniczna"},{"name":"węgiel (kamienny, brunatny)"},{"name":"Zakres","range":"(0,19 – 34,72) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna\nZakres:\napatyty i fosforyty\ncement portlandzki\nditlenek tytanu\nkaolin\nkrzemionka bezpostaciowa i syntetyczna\npyły drewna\npyły mąki\npyły niesklasyfikowane ze względu na toksyczność\npyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nsiarczan (VI) wapnia (gips)\nsadza techniczna\nwęgiel (kamienny, brunatny)\nZakres (0,19 – 34,72) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05","PN-Z-04507:2022-05/Ap1:2022-08"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna\nZakres:\napatyty i fosforyty\ncement portlandzki\nditlenek tytanu\nkaolin\nkrzemionka bezpostaciowa i syntetyczna\npyły drewna\npyły mąki\npyły niesklasyfikowane ze względu na toksyczność\npyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nsiarczan (VI) wapnia (gips)\nsadza techniczna\nwęgiel (kamienny, brunatny)\nZakres (0,19 – 34,72) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia – frakcja wdychalna\nZakres:\napatyty i fosforyty\ncement portlandzki\nditlenek tytanu\nkaolin\nkrzemionka bezpostaciowa i syntetyczna\npyly drewna\npyly maki\npyly niesklasyfikowane ze wzgledu na toksycznosc\npyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nsiarczan (VI) wapnia (gips)\nsadza techniczna\nwegiel (kamienny, brunatny)\nZakres (0,19 – 34,72) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of harmful dust agents – inhalable fraction","parameters_en":[{"name":"apatites and phosphorites"},{"name":"portland cement"},{"name":"titanium dioxide"},{"name":"kaolin"},{"name":"amorphous and synthetic silica"},{"name":"wood dusts"},{"name":"flour dusts"},{"name":"dusts not classified according to toxicity"},{"name":"organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"calcium sulfate (VI) (gypsum)"},{"name":"carbon black"},{"name":"coal (hard, brown)"},{"name":"Range","range":"(0,19 – 34,72) mg/m3"}],"search_en":"Workplace environment - air Concentration of harmful dust agents – inhalable fraction Gravimetric method apatites and phosphorites portland cement titanium dioxide kaolin amorphous and synthetic silica wood dusts flour dusts dusts not classified according to toxicity organic dusts of animal and plant origin, excluding wood and flour dusts calcium sulfate (VI) (gypsum) carbon black coal (hard, brown) Range PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"二氧化钛"},{"name":"高岭土"},{"name":"无定形与合成二氧化硅"},{"name":"木粉尘"},{"name":"面粉粉尘"},{"name":"未按毒性分类的粉尘"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"硫酸钙（VI）（石膏）"},{"name":"炭黑"},{"name":"煤（烟煤、褐煤）"},{"name":"范围","range":"(0,19 – 34,72) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 可吸入组分 重量法 磷灰石与磷块岩 硅酸盐水泥 二氧化钛 高岭土 无定形与合成二氧化硅 木粉尘 面粉粉尘 未按毒性分类的粉尘 动植物来源有机粉尘，木粉和面粉除外 硫酸钙（VI）（石膏） 炭黑 煤（烟煤、褐煤） 范围 PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害粉尘因素浓度 — 可吸入组分"},{"_id":"6a7d795f0636ba417e41a966","lab_id":"69ad52a3de79e566650fb694","country":"PL","accr_number":"AB 1285","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna","parameters":[{"name":"apatyty i fosforyty"},{"name":"cement portlandzki"},{"name":"krzemionka bezpostaciowa i syntetyczna"},{"name":"pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"węgiel (kamienny, brunatny)"},{"name":"Zakres","range":"(0,10 – 18,94) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna\nZakres:\napatyty i fosforyty\ncement portlandzki\nkrzemionka bezpostaciowa i syntetyczna\npyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nwęgiel (kamienny, brunatny)\nZakres (0,10 – 18,94) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04508:2022-05","PN-Z-04508:2022-05/Ap1:2022-08"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna\nZakres:\napatyty i fosforyty\ncement portlandzki\nkrzemionka bezpostaciowa i syntetyczna\npyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nwęgiel (kamienny, brunatny)\nZakres (0,10 – 18,94) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia – frakcja respirabilna\nZakres:\napatyty i fosforyty\ncement portlandzki\nkrzemionka bezpostaciowa i syntetyczna\npyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nwegiel (kamienny, brunatny)\nZakres (0,10 – 18,94) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of harmful dust agents – respirable fraction","parameters_en":[{"name":"apatites and phosphorites"},{"name":"portland cement"},{"name":"amorphous and synthetic silica"},{"name":"organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"coal (hard, brown)"},{"name":"Range","range":"(0,10 – 18,94) mg/m3"}],"search_en":"Workplace environment - air Concentration of harmful dust agents – respirable fraction Gravimetric method apatites and phosphorites portland cement amorphous and synthetic silica organic dusts of animal and plant origin, excluding wood and flour dusts coal (hard, brown) Range PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"无定形与合成二氧化硅"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"煤（烟煤、褐煤）"},{"name":"范围","range":"(0,10 – 18,94) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 呼吸性组分 重量法 磷灰石与磷块岩 硅酸盐水泥 无定形与合成二氧化硅 动植物来源有机粉尘，木粉和面粉除外 煤（烟煤、褐煤） 范围 PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害粉尘因素浓度 — 呼吸性组分"},{"_id":"6a7d795f0636ba417e41a967","lab_id":"69ad52a3de79e566650fb694","country":"PL","accr_number":"AB 1285","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie tlenku węgla","parameters":[{"name":"Zakres","range":"(2,3 – 234) mg/m3"},{"name":"Zakres","range":"(2 – 200) ppm"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie tlenku węgla\nZakres:\nZakres (2,3 – 234) mg/m3\nZakres (2 – 200) ppm\nMetoda elektrochemiczna","reference":"PB-8 ed. 2 z dn. 18.08.2025 r.","norm_bases":["PB-8 ed. 2 z dn. 18.08.2025 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie tlenku węgla\nZakres:\nZakres (2,3 – 234) mg/m3\nZakres (2 – 200) ppm\nMetoda elektrochemiczna PB-8 ed. 2 z dn. 18.08.2025 r. Srodowisko pracy - powietrze Stezenie tlenku wegla\nZakres:\nZakres (2,3 – 234) mg/m3\nZakres (2 – 200) ppm\nMetoda elektrochemiczna PB-8 ed. 2 z dn. 18.08.2025 r.","categories":["environment"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Carbon monoxide concentration","parameters_en":[{"name":"Range","range":"(2,3 – 234) mg/m3"},{"name":"Range","range":"(2 – 200) ppm"}],"search_en":"Workplace environment - air Carbon monoxide concentration Electrochemical method Range Range PB-8 ed. 2 z dn. 18.08.2025 r.","technique_en":"Electrochemical method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"范围","range":"(2,3 – 234) mg/m3"},{"name":"范围","range":"(2 – 200) ppm"}],"search_zh":"工作场所环境 — 空气 一氧化碳浓度 电化学法 范围 范围 PB-8 ed. 2 z dn. 18.08.2025 r.","technique_zh":"电化学法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"一氧化碳浓度"},{"_id":"6a7d795f0636ba417e41a968","lab_id":"69ad52a3de79e566650fb694","country":"PL","accr_number":"AB 1285","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Wskaźniki narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźniki narażenia (z obliczeń)","reference":"PB-8 ed. 2 z dn. 18.08.2025 r.","norm_bases":["PB-8 ed. 2 z dn. 18.08.2025 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Wskaźniki narażenia (z obliczeń) PB-8 ed. 2 z dn. 18.08.2025 r. Srodowisko pracy - powietrze Wskazniki narazenia (z obliczen) PB-8 ed. 2 z dn. 18.08.2025 r.","categories":["environment"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Exposure indices (calculated)","search_en":"Workplace environment - air Exposure indices (calculated) PB-8 ed. 2 z dn. 18.08.2025 r.","test_object_en":"Workplace environment - air","search_zh":"工作场所环境 — 空气 暴露指数（计算值） PB-8 ed. 2 z dn. 18.08.2025 r.","test_object_zh":"工作场所环境 — 空气","methodology_zh":"暴露指数（计算值）"},{"_id":"6a7d795f0636ba417e41a969","lab_id":"69ad52a3de79e566650fb694","country":"PL","accr_number":"AB 1285","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie/zawartość manganu i jego związków nieorganicznych w przeliczeniu na Mn – frakcja wdychalna","parameters":[{"name":"Zakres","range":"(0,017-0,417) mg/m3"},{"name":"Zakres","range":"(0,012-0,300) mg w próbce"},{"name":"– frakcja respirabilna"},{"name":"Zakres","range":"(0,004 - 0,379) mg/m3"},{"name":"Zakres","range":"(0,003 - 0,300) mg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość manganu i jego związków nieorganicznych w przeliczeniu na Mn – frakcja wdychalna\nZakres:\nZakres (0,017-0,417) mg/m3\nZakres (0,012-0,300) mg w próbce\n– frakcja respirabilna\nZakres (0,004 - 0,379) mg/m3\nZakres (0,003 - 0,300) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04472:2015-10+Ap1:2015-12","norm_bases":["PN-Z-04472:2015-10+Ap1:2015-12"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie/zawartość manganu i jego związków nieorganicznych w przeliczeniu na Mn – frakcja wdychalna\nZakres:\nZakres (0,017-0,417) mg/m3\nZakres (0,012-0,300) mg w próbce\n– frakcja respirabilna\nZakres (0,004 - 0,379) mg/m3\nZakres (0,003 - 0,300) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04472:2015-10+Ap1:2015-12 Srodowisko pracy - powietrze Stezenie/zawartosc manganu i jego zwiazkow nieorganicznych w przeliczeniu na Mn – frakcja wdychalna\nZakres:\nZakres (0,017-0,417) mg/m3\nZakres (0,012-0,300) mg w probce\n– frakcja respirabilna\nZakres (0,004 - 0,379) mg/m3\nZakres (0,003 - 0,300) mg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04472:2015-10+Ap1:2015-12","categories":["environment"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of manganese and its inorganic compounds calculated as Mn – inhalable fraction","parameters_en":[{"name":"Range","range":"(0,017-0,417) mg/m3"},{"name":"Range","range":"(0,012-0,300) mg w próbce"},{"name":"– respirable fraction"},{"name":"Range","range":"(0,004 - 0,379) mg/m3"},{"name":"Range","range":"(0,003 - 0,300) mg w próbce"}],"search_en":"Workplace environment - air Concentration/content of manganese and its inorganic compounds calculated as Mn – inhalable fraction Flame atomic absorption spectrometry (FAAS) Range Range – respirable fraction Range Range PN-Z-04472:2015-10+Ap1:2015-12","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"范围","range":"(0,017-0,417) mg/m3"},{"name":"范围","range":"(0,012-0,300) mg w próbce"},{"name":"— 呼吸性组分"},{"name":"范围","range":"(0,004 - 0,379) mg/m3"},{"name":"范围","range":"(0,003 - 0,300) mg w próbce"}],"search_zh":"工作场所环境 — 空气 火焰原子吸收光谱法（FAAS） 范围 范围 — 呼吸性组分 范围 范围 PN-Z-04472:2015-10+Ap1:2015-12","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a7d795f0636ba417e41a96a","lab_id":"69ad52a3de79e566650fb694","country":"PL","accr_number":"AB 1285","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie/zawartość tlenków żelaza w przeliczeniu na Fe tlenek żelaza III tlenek żelaza II tetratlenek triżelaza","parameters":[{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(0,347 – 125) mg/m3"},{"name":"Zakres","range":"(0,05 – 15) mg w próbce"},{"name":"frakcja respirabilna"},{"name":"Zakres","range":"(0,158 – 56,82) mg/m3"},{"name":"Zakres","range":"(0,05 – 7,50) mg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość tlenków żelaza w przeliczeniu na Fe tlenek żelaza III tlenek żelaza II tetratlenek triżelaza\nZakres:\nfrakcja wdychalna\nZakres (0,347 – 125) mg/m3\nZakres (0,05 – 15) mg w próbce\nfrakcja respirabilna\nZakres (0,158 – 56,82) mg/m3\nZakres (0,05 – 7,50) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04469:2025-02","norm_bases":["PN-Z-04469:2025-02"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie/zawartość tlenków żelaza w przeliczeniu na Fe tlenek żelaza III tlenek żelaza II tetratlenek triżelaza\nZakres:\nfrakcja wdychalna\nZakres (0,347 – 125) mg/m3\nZakres (0,05 – 15) mg w próbce\nfrakcja respirabilna\nZakres (0,158 – 56,82) mg/m3\nZakres (0,05 – 7,50) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04469:2025-02 Srodowisko pracy - powietrze Stezenie/zawartosc tlenkow zelaza w przeliczeniu na Fe tlenek zelaza III tlenek zelaza II tetratlenek trizelaza\nZakres:\nfrakcja wdychalna\nZakres (0,347 – 125) mg/m3\nZakres (0,05 – 15) mg w probce\nfrakcja respirabilna\nZakres (0,158 – 56,82) mg/m3\nZakres (0,05 – 7,50) mg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04469:2025-02","categories":["environment"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of iron oxides calculated as Fe iron(III) oxide iron(II) oxide triiron tetraoxide","parameters_en":[{"name":"inhalable fraction"},{"name":"Range","range":"(0,347 – 125) mg/m3"},{"name":"Range","range":"(0,05 – 15) mg w próbce"},{"name":"respirable fraction"},{"name":"Range","range":"(0,158 – 56,82) mg/m3"},{"name":"Range","range":"(0,05 – 7,50) mg w próbce"}],"search_en":"Workplace environment - air Concentration/content of iron oxides calculated as Fe iron(III) oxide iron(II) oxide triiron tetraoxide Flame atomic absorption spectrometry (FAAS) inhalable fraction Range Range respirable fraction Range Range PN-Z-04469:2025-02","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"可吸入组分"},{"name":"范围","range":"(0,347 – 125) mg/m3"},{"name":"范围","range":"(0,05 – 15) mg w próbce"},{"name":"呼吸性组分"},{"name":"范围","range":"(0,158 – 56,82) mg/m3"},{"name":"范围","range":"(0,05 – 7,50) mg w próbce"}],"search_zh":"工作场所环境 — 空气 火焰原子吸收光谱法（FAAS） 可吸入组分 范围 范围 呼吸性组分 范围 范围 PN-Z-04469:2025-02","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a7d795f0636ba417e41a96b","lab_id":"69ad52a3de79e566650fb694","country":"PL","accr_number":"AB 1285","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(5 – 5000) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (5 – 5000) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-83/E-04040.03 | PB-3 ed. 5 z dn. 21.05.2021r.","norm_bases":["PN-83/E-04040.03","PB-3 ed. 5 z dn. 21.05.2021r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie Natężenie oświetlenia\nZakres (5 – 5000) lx\nMetoda pomiarowa bezpośrednia PN-83/E-04040.03 | PB-3 ed. 5 z dn. 21.05.2021r. Srodowisko pracy - oswietlenie Natezenie oswietlenia\nZakres (5 – 5000) lx\nMetoda pomiarowa bezposrednia PN-83/E-04040.03 | PB-3 ed. 5 z dn. 21.05.2021r.","categories":["environment"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance","parameters_en":[{"name":"Range","range":"(5 – 5000) lx"}],"search_en":"Workplace environment - lighting Illuminance Direct measurement method Range PN-83/E-04040.03 | PB-3 ed. 5 z dn. 21.05.2021r.","technique_en":"Direct measurement method","test_object_en":"Workplace environment - lighting","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(5 – 5000) lx"}],"search_zh":"工作环境 － 照明 照度 直接测量法 范围 PN-83/E-04040.03 | PB-3 ed. 5 z dn. 21.05.2021r.","technique_zh":"直接测量法","test_object_zh":"工作环境 － 照明"},{"_id":"6a7d795f0636ba417e41a96c","lab_id":"69ad52a3de79e566650fb694","country":"PL","accr_number":"AB 1285","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie","methodology":"Równomierność oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"PN-83/E-04040.03 | PB-3 ed. 5 z dn. 21.05.2021r.","norm_bases":["PN-83/E-04040.03","PB-3 ed. 5 z dn. 21.05.2021r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie Równomierność oświetlenia (z obliczeń) PN-83/E-04040.03 | PB-3 ed. 5 z dn. 21.05.2021r. Srodowisko pracy - oswietlenie Rownomiernosc oswietlenia (z obliczen) PN-83/E-04040.03 | PB-3 ed. 5 z dn. 21.05.2021r.","categories":["environment"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance uniformity (calculated)","search_en":"Workplace environment - lighting Illuminance uniformity (calculated) PN-83/E-04040.03 | PB-3 ed. 5 z dn. 21.05.2021r.","test_object_en":"Workplace environment - lighting","methodology_zh":"照度均匀度（计算值）","search_zh":"工作环境 － 照明 照度均匀度（计算值） PN-83/E-04040.03 | PB-3 ed. 5 z dn. 21.05.2021r.","test_object_zh":"工作环境 － 照明"},{"_id":"6a7d795f0636ba417e41a96d","lab_id":"69ad52a3de79e566650fb694","country":"PL","accr_number":"AB 1285","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(40 – 130) dB"},{"name":"Szczytowy poziom dźwięku C"},{"name":"Zakres","range":"(55 – 136) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (40 – 130) dB\nSzczytowy poziom dźwięku C\nZakres (55 – 136) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i Strategię 3 – punkt 10 i punkt 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i Strategię 3 – punkt 10 i punkt 11"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (40 – 130) dB\nSzczytowy poziom dźwięku C\nZakres (55 – 136) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i Strategię 3 – punkt 10 i punkt 11 Srodowisko pracy - halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres:\nZakres (40 – 130) dB\nSzczytowy poziom dzwieku C\nZakres (55 – 136) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej Strategie 2 i Strategie 3 – punkt 10 i punkt 11","categories":["environment"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters_en":[{"name":"Range","range":"(40 – 130) dB"},{"name":"C-weighted peak sound pressure level"},{"name":"Range","range":"(55 – 136) dB"}],"search_en":"Workplace environment - noise A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method Range C-weighted peak sound pressure level Range PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i Strategię 3 – punkt 10 i punkt 11","technique_en":"Direct measurement method","test_object_en":"Workplace environment - noise","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(40 – 130) dB"},{"name":"C 计权峰值声级"},{"name":"范围","range":"(55 – 136) dB"}],"search_zh":"工作场所环境 — 噪声 A 计权等效声级 A 计权最大声级 直接测量法 范围 C 计权峰值声级 范围 PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i Strategię 3 – punkt 10 i punkt 11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a7d795f0636ba417e41a96e","lab_id":"69ad52a3de79e566650fb694","country":"PL","accr_number":"AB 1285","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Poziom ekspozycji na hałas odniesiony do:","parameters":[{"name":"8-godzinnego dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godzinnego dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i Strategię 3 – punkt 10 i punkt 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i Strategię 3 – punkt 10 i punkt 11"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godzinnego dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i Strategię 3 – punkt 10 i punkt 11 Srodowisko pracy - halas Poziom ekspozycji na halas odniesiony do:\nZakres:\n8-godzinnego dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej Strategie 2 i Strategie 3 – punkt 10 i punkt 11","categories":["environment"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Noise exposure level referred to:","parameters_en":[{"name":"an 8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"search_en":"Workplace environment - noise Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i Strategię 3 – punkt 10 i punkt 11","test_object_en":"Workplace environment - noise","methodology_zh":"噪声暴露级，参照：","parameters_zh":[{"name":"8 小时日工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作场所环境 — 噪声 噪声暴露级，参照： 8 小时日工作时间 平均每周工作时间（计算值） PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i Strategię 3 – punkt 10 i punkt 11","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a7d795f0636ba417e41a96f","lab_id":"69ad52a3de79e566650fb694","country":"PL","accr_number":"AB 1285","accr_body":"PCA","test_object":"Środowisko pracy - drgania przenoszone przez kończyny górne","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,32 – 100) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,32 – 100) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN-ISO 5349-1:2004 | PN-EN-ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN-ISO 5349-1:2004","PN-EN-ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - drgania przenoszone przez kończyny górne Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,32 – 100) m/s2\nMetoda pomiarowa bezpośrednia PN-EN-ISO 5349-1:2004 | PN-EN-ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy - drgania przenoszone przez konczyny gorne Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,32 – 100) m/s2\nMetoda pomiarowa bezposrednia PN-EN-ISO 5349-1:2004 | PN-EN-ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters_en":[{"name":"Range","range":"(0,32 – 100) m/s2"}],"search_en":"Workplace environment - hand-arm vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method Range PN-EN-ISO 5349-1:2004 | PN-EN-ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","technique_en":"Direct measurement method","test_object_en":"Workplace environment - hand-arm vibration","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,32 – 100) m/s2"}],"search_zh":"工作环境 － 经上肢传递的振动 频率计权振动加速度有效值 直接测量法 范围 PN-EN-ISO 5349-1:2004 | PN-EN-ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","technique_zh":"直接测量法","test_object_zh":"工作环境 － 经上肢传递的振动"},{"_id":"6a7d795f0636ba417e41a970","lab_id":"69ad52a3de79e566650fb694","country":"PL","accr_number":"AB 1285","accr_body":"PCA","test_object":"Środowisko pracy - drgania przenoszone przez kończyny górne","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","reference":"PN-EN-ISO 5349-1:2004 | PN-EN-ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN-ISO 5349-1:2004","PN-EN-ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - drgania przenoszone przez kończyny górne Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń) PN-EN-ISO 5349-1:2004 | PN-EN-ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy - drgania przenoszone przez konczyny gorne Ekspozycja dzienna, wyrazona w postaci rownowaznej energetycznie dla 8-godzin dzialania sumy wektorowej skutecznych, skorygowanych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci sumy wektorowej skutecznych, wazonych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz) (z obliczen) PN-EN-ISO 5349-1:2004 | PN-EN-ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated)","search_en":"Workplace environment - hand-arm vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated) PN-EN-ISO 5349-1:2004 | PN-EN-ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","test_object_en":"Workplace environment - hand-arm vibration","methodology_zh":"日暴露量，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值矢量和的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值的矢量和表示（计算值）","search_zh":"工作环境 － 经上肢传递的振动 日暴露量，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值矢量和的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值的矢量和表示（计算值） PN-EN-ISO 5349-1:2004 | PN-EN-ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","test_object_zh":"工作环境 － 经上肢传递的振动"},{"_id":"6a7d795f0636ba417e41a971","lab_id":"69ad52a3de79e566650fb694","country":"PL","accr_number":"AB 1285","accr_body":"PCA","test_object":"Środowisko pracy - drgania o działaniu ogólnym na organizm człowieka","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,08 – 25) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,08 – 25) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - drgania o działaniu ogólnym na organizm człowieka Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,08 – 25) m/s2\nMetoda pomiarowa bezpośrednia PN-EN 14253+A1:2011 Srodowisko pracy - drgania o dzialaniu ogolnym na organizm czlowieka Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,08 – 25) m/s2\nMetoda pomiarowa bezposrednia PN-EN 14253+A1:2011","categories":["environment"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters_en":[{"name":"Range","range":"(0,08 – 25) m/s2"}],"search_en":"Workplace environment - whole-body vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method Range PN-EN 14253+A1:2011","technique_en":"Direct measurement method","test_object_en":"Workplace environment - whole-body vibration","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,08 – 25) m/s2"}],"search_zh":"工作环境 － 对人体产生全身作用的振动 频率计权振动加速度有效值 直接测量法 范围 PN-EN 14253+A1:2011","technique_zh":"直接测量法","test_object_zh":"工作环境 － 对人体产生全身作用的振动"},{"_id":"6a7d795f0636ba417e41a972","lab_id":"69ad52a3de79e566650fb694","country":"PL","accr_number":"AB 1285","accr_body":"PCA","test_object":"Środowisko pracy - drgania o działaniu ogólnym na organizm człowieka","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń)","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - drgania o działaniu ogólnym na organizm człowieka Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń) PN-EN 14253+A1:2011 Srodowisko pracy - drgania o dzialaniu ogolnym na organizm czlowieka Ekspozycja dzienna, wyrazona w postaci rownowaznego energetycznie dla 8-godzin dzialania skutecznego, skorygowanego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4awx, 1.4awy, awz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci skutecznego, wazonego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4awx, 1.4awy, awz) (z obliczen) PN-EN 14253+A1:2011","categories":["environment"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated)","search_en":"Workplace environment - whole-body vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated) PN-EN 14253+A1:2011","test_object_en":"Workplace environment - whole-body vibration","methodology_zh":"日暴露量，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值表示（计算值）","search_zh":"工作环境 － 对人体产生全身作用的振动 日暴露量，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值表示（计算值） PN-EN 14253+A1:2011","test_object_zh":"工作环境 － 对人体产生全身作用的振动"},{"_id":"6a7d795f0636ba417e41a973","lab_id":"69ad52a3de79e566650fb694","country":"PL","accr_number":"AB 1285","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":"Metoda manualna","techniques":["Metoda manualna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Wastewater Sampling for chemical and physical testing Manual method PN-ISO 5667-10:2021-11","technique_en":"Manual method","test_object_en":"Wastewater","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水 化学与物理检测用样品采集 手工法 PN-ISO 5667-10:2021-11","test_object_zh":"污水","technique_zh":"手工法"},{"_id":"6a7d795f0636ba417e41a974","lab_id":"69ad52a3de79e566650fb694","country":"PL","accr_number":"AB 1285","accr_body":"PCA","test_object":"Ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Scieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"search_en":"Wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"污水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"污水"},{"_id":"6a7d795f0636ba417e41a975","lab_id":"69ad52a3de79e566650fb694","country":"PL","accr_number":"AB 1285","accr_body":"PCA","test_object":"Ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(5,0 – 125) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (5,0 – 125) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007 + Ap1:2007","norm_bases":["PN-EN 872:2007 + Ap1:2007"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Zawiesiny ogólne\nZakres (5,0 – 125) mg/l\nMetoda wagowa PN-EN 872:2007 + Ap1:2007 Scieki Zawiesiny ogolne\nZakres (5,0 – 125) mg/l\nMetoda wagowa PN-EN 872:2007 + Ap1:2007","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(5,0 – 125) mg/l"}],"search_en":"Wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007 + Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(5,0 – 125) mg/l"}],"search_zh":"污水 总悬浮物 重量法 范围 PN-EN 872:2007 + Ap1:2007","technique_zh":"重量法","test_object_zh":"污水"},{"_id":"6a7d795f0636ba417e41a976","lab_id":"69ad52a3de79e566650fb694","country":"PL","accr_number":"AB 1285","accr_body":"PCA","test_object":"Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu – ChZT","parameters":[{"name":"Zakres","range":"(10,0 – 150) mg/I O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu – ChZT\nZakres (10,0 – 150) mg/I O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu – ChZT\nZakres (10,0 – 150) mg/I O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Scieki Chemiczne zapotrzebowanie tlenu – ChZT\nZakres (10,0 – 150) mg/I O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand – COD","parameters_en":[{"name":"Range","range":"(10,0 – 150) mg/I O2"}],"search_en":"Wastewater Chemical oxygen demand – COD Spectrophotometric method Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(10,0 – 150) mg/I O2"}],"search_zh":"污水 化学需氧量 － COD 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"化学需氧量 － COD"},{"_id":"6a7d795f0636ba417e41a977","lab_id":"69ad52a3de79e566650fb694","country":"PL","accr_number":"AB 1285","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie chromu","parameters":[{"name":"Zakres","range":"(0,250 – 2,00) mg/I"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie chromu\nZakres (0,250 – 2,00) mg/I\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PB-06 ed. 2 z dn. 01.08.2024 r.","norm_bases":["PB-06 ed. 2 z dn. 01.08.2024 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie chromu\nZakres (0,250 – 2,00) mg/I\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-06 ed. 2 z dn. 01.08.2024 r. Scieki Stezenie chromu\nZakres (0,250 – 2,00) mg/I\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-06 ed. 2 z dn. 01.08.2024 r.","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chromium concentration","parameters_en":[{"name":"Range","range":"(0,250 – 2,00) mg/I"}],"search_en":"Wastewater Chromium concentration Flame atomic absorption spectrometry (FAAS) Range PB-06 ed. 2 z dn. 01.08.2024 r.","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(0,250 – 2,00) mg/I"}],"search_zh":"污水 铬浓度 火焰原子吸收光谱法（FAAS） 范围 PB-06 ed. 2 z dn. 01.08.2024 r.","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"污水","methodology_zh":"铬浓度"},{"_id":"6a7d795f0636ba417e41a978","lab_id":"69ad52a3de79e566650fb694","country":"PL","accr_number":"AB 1285","accr_body":"PCA","test_object":"Woda i ścieki","methodology":"Stężenie metali","parameters":[{"name":"żelazo","range":"(0,2 – 20,0) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie metali\nżelazo (0,2 – 20,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PB-04 ed. 3 z dn. 01.08.2024 r.","norm_bases":["PB-04 ed. 3 z dn. 01.08.2024 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda i ścieki Stężenie metali\nżelazo (0,2 – 20,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-04 ed. 3 z dn. 01.08.2024 r. Woda i scieki Stezenie metali\nzelazo (0,2 – 20,0) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-04 ed. 3 z dn. 01.08.2024 r.","categories":["water","materials"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal concentrations","parameters_en":[{"name":"iron","range":"(0,2 – 20,0) mg/l"}],"search_en":"Water and wastewater Metal concentrations Flame atomic absorption spectrometry (FAAS) iron PB-04 ed. 3 z dn. 01.08.2024 r.","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Water and wastewater","methodology_zh":"金属浓度","search_zh":"水与废水 金属浓度 火焰原子吸收光谱法（FAAS） 铁 PB-04 ed. 3 z dn. 01.08.2024 r.","technique_zh":"火焰原子吸收光谱法（FAAS）","parameters_zh":[{"name":"铁","range":"(0,2 – 20,0) mg/l"}],"test_object_zh":"水与废水"},{"_id":"6a7d795f0636ba417e41a979","lab_id":"69ad52a3de79e566650fb694","country":"PL","accr_number":"AB 1285","accr_body":"PCA","test_object":"Woda i ścieki","methodology":"Stężenie metali","parameters":[{"name":"cynk","range":"(0,05 – 4,0) mg/l"},{"name":"miedź","range":"(0,05 – 6,0) mg/l"},{"name":"nikiel","range":"(0,2 – 10,0) mg/l"},{"name":"ołów","range":"(0,2 – 10,0) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie metali\nZakres:\ncynk (0,05 – 4,0) mg/l\nmiedź (0,05 – 6,0) mg/l\nnikiel (0,2 – 10,0) mg/l\nołów (0,2 – 10,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 8288:2002","norm_bases":["PN-ISO 8288:2002"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda i ścieki Stężenie metali\nZakres:\ncynk (0,05 – 4,0) mg/l\nmiedź (0,05 – 6,0) mg/l\nnikiel (0,2 – 10,0) mg/l\nołów (0,2 – 10,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 Woda i scieki Stezenie metali\nZakres:\ncynk (0,05 – 4,0) mg/l\nmiedz (0,05 – 6,0) mg/l\nnikiel (0,2 – 10,0) mg/l\nolow (0,2 – 10,0) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002","categories":["materials","water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal concentrations","parameters_en":[{"name":"zinc","range":"(0,05 – 4,0) mg/l"},{"name":"copper","range":"(0,05 – 6,0) mg/l"},{"name":"nickel","range":"(0,2 – 10,0) mg/l"},{"name":"lead","range":"(0,2 – 10,0) mg/l"}],"search_en":"Water and wastewater Metal concentrations Flame atomic absorption spectrometry (FAAS) zinc copper nickel lead PN-ISO 8288:2002","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Water and wastewater","methodology_zh":"金属浓度","parameters_zh":[{"name":"锌","range":"(0,05 – 4,0) mg/l"},{"name":"铜","range":"(0,05 – 6,0) mg/l"},{"name":"镍","range":"(0,2 – 10,0) mg/l"},{"name":"铅","range":"(0,2 – 10,0) mg/l"}],"search_zh":"水与废水 金属浓度 火焰原子吸收光谱法（FAAS） 锌 铜 镍 铅 PN-ISO 8288:2002","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水与废水"}],"has_pdf":true}