🇵🇱 GŁÓWNY INSPEKTORAT OCHRONY ŚRODOWISKA PL
Water & wastewaterEnvironmentMaterials & polymers
GŁÓWNY INSPEKTORAT OCHRONY ŚRODOWISKA is a laboratory accredited by PCA under number AB 127 (Warszawa, Poland). Its accreditation scope covers 83 test methods in the following areas: Water & wastewater, Environment, Materials & polymers. Test objects include: Water, Wastewater, Water, Sewage sludge, Waste code O): 19 08 05. Most frequently used techniques: Spectrophotometric method, Titrimetric method, Gravimetric method.
At a glance
- Accreditation number: PCA AB 127
- Methods in scope: 83
- Types of test objects: 8
- Techniques used: 17
- City: Warszawa, Poland
- Accreditation number
- AB 127
- Accreditation body
- PCA
- Address
- ul. Chmielna 132/134, 00-805 Warszawa, CENTRALNE LABORATORIUM BADAWCZE, ODDZIAŁ W ZIELONEJ GÓRZE
- City
- Warszawa, Poland
What this laboratory tests (8)
- Water, Wastewater — 31 methods
- Water — 23 methods
- Sewage sludge — 7 methods
- Waste code O): 19 08 05 — 7 methods
- Soil — 6 methods
- Wastewater — 5 methods
- Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) — 2 methods
- General environment – noise from installations, equipment and industrial plants — 2 methods
Analytical techniques used (17)
- Spectrophotometric method — 24 methods
- Titrimetric method — 9 methods
- Gravimetric method — 8 methods
- Electrochemical method — 5 methods
- Inductively coupled plasma optical emission spectrometry (ICP-OES) — 5 methods
- Ion chromatography with conductometric detection (IC-CD) — 4 methods
- Potentiometric method — 4 methods
- Direct measurement method — 2 methods
- Gas chromatography with flame ionization detection (GC-FID) — 2 methods
- High-performance liquid chromatography with fluorescence detection (HPLC-FLD) — 2 methods
- Inductively coupled plasma mass spectrometry (ICP-MS) — 2 methods
- Conductometric method — 1 method
- Continuous flow analysis (CFA) with spectrophotometric detection — 1 method
- Infrared spectrometry method (IR) — 1 method
- Manual and automatic method — 1 method
- and 2 more
Laboratory sections (3)
- Pracownia w Zielonej Górze — 41 methods
- Pracownia w Gorzowie Wielkopolskim — 27 methods
- Pracownia Terenowa — 15 methods
Laboratory locations
- CENTRALNE LABORATORIUM BADAWCZE ODDZIAŁ W ZIELONEJ GÓRZE — ul. Siemiradzkiego 19
- Pracownia w Gorzowie Wielkopolskim — ul. Kostrzyńska 48, 66-400 Gorzów Wielkopolski
- Pracownia w Zielonej Górze — ul. Siemiradzkiego 19, 65-231 Zielona Góra
- Pracownia Terenowa — ul. Siemiradzkiego 19, 65-231 Zielona Góra
Accreditation scope — test methods (83)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Pracownia w Gorzowie Wielkopolskim | |||||
| 1 | Water | Total content of calcium and magnesium (total hardness) Range (2,5 – 500) mg/l CaCO3 |
Titrimetric method | PN-ISO 6059:1999 | |
| 2 | Water | Cyanide concentration Range (0,007 − 0,200) mg/l |
Spectrophotometric method | PB-69/ZG wydanie 1 z dnia 10.01.2020 r. | na podstawie testu kuwetowego HACH LANGE nr 8027 | |
| 3 | Water | Stężenie chromu sześciowartościowego rozpuszczonego Range (0,006 – 2,0) mg/l |
Spectrophotometric method | PN-EN ISO 18724:2026-04 | |
| 4 | Water | Calcium concentration Range (2,0 – 200) mg/l Ca |
Titrimetric method | PN-ISO 6058:1999 | |
| 5 | Water | Colour Range (5 – 100) mg/l Pt |
Spectrophotometric method | PN-EN ISO 7887:2012, metoda C | |
| 6 | Water | Total alkalinity Range (10,0– 250) mg/l CaCO3 Range (0,2 – 5,0) mmol/l |
Titrimetric method | PN-EN ISO 9963-1:2001+Ap1:2004 | |
| 7 | Water | Permanganate index Range (0,6 – 60) mg/l |
Titrimetric method | PN-EN ISO 8467:2001 | |
| 8 | Water | Stężenie ogólnego węgla organicznego i rozpuszczonego Range (1,8 – 400) mg/l |
Infrared spectrometry method (IR) | PN-EN 1484:1999 | |
| 9 | Water | Anion concentrations: sulfates (2,0 – 1000) mg/l chlorides (2,0 – 1000) mg/l nitrate nitrogen (0,050 – 50) mg/l nitrates (0,20-220) mg/l fluorides (0,050-2,0) mg/l |
Ion chromatography with conductometric detection (IC-CD) | PN-EN ISO 10304-1:2009+AC:2012 | |
| 10 | Water | Biochemical oxygen demand - BOD5 Range (0,44 – 6) mg/l O2 |
Electrochemical method | PN-EN 1899-2:2002 | |
| 11 | Water, Wastewater | Ammonium ion concentration Range (4,12 – 1288) mg/l Ammonium nitrogen concentration Range (3,2 – 1000) mg/l |
Titrimetric method | PN-ISO 5664:2002 | |
| 12 | Water, Wastewater | Nitrite nitrogen concentration Range (0,001 – 6,0) mg/l Nitrite concentration Range (0,003 – 20,0) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 13 | Water, Wastewater | Total nitrogen concentration (calculated) | PB-26/CLB wydanie 1 z dnia 16.01.2026 r. | ||
| 14 | Water, Wastewater | Kjeldahl nitrogen concentration Range (0,25 – 10) mg/l |
Spectrophotometric method | PN-EN 25663:2001 | |
| 15 | Water, Wastewater | Kjeldahl nitrogen concentration Range (3,2 – 1000) mg/l |
Titrimetric method | PN-EN 25663:2001 | |
| 16 | Water, Wastewater | Dissolved orthophosphate concentration Range (0,018 – 18) mg/l PO4 |
Spectrophotometric method | PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 p. 4 | |
| 17 | Water, Wastewater | Total phosphorus concentration Range (0,018 – 25) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 p. 7 | |
| 18 | Water, Wastewater | Total phosphorus concentration Range (0,10-10) mg/l |
Continuous flow analysis (CFA) with spectrophotometric detection | PN-EN ISO 15681-2:2019-02 | |
| 19 | Water, Wastewater | Concentration of substances extractable with petroleum ether Range (11,5 – 1600) mg/l |
Gravimetric method | PB-36/ZG wydanie 1 z dnia 10.01.2020 r. | |
| 20 | Water, Wastewater | Phenol index Range (0,001 – 0,50) mg/l |
Spectrophotometric method | PN-ISO 6439:1994 | |
| 21 | Water, Wastewater | Anionic detergent concentration Range (0,06 – 48,4) mg/l |
Spectrophotometric method | PN-EN 903:2002 | |
| 22 | Water, Wastewater | Ammonium ion concentration Range (0,021 – 13) mg/l Ammonium nitrogen concentration Range (0,016 – 10) mg/l |
Spectrophotometric method | PN-ISO 7150-1:2002 | |
| 23 | Water, Wastewater | Total suspended solids (TSS) Range (3,0 – 5500) mg/l |
Gravimetric method | PN-EN 872:2007+Ap1:2007 | |
| 24 | Water, Wastewater | Biochemical oxygen demand - BOD5 Range (3,0 – 6000) mg/l O2 |
Electrochemical method | PN-EN ISO 5815-1:2019-12 | |
| 25 | Water, Wastewater | Chemical oxygen demand - COD-Cr Range (10 – 1000) mg/l O2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 26 | Wastewater | Hexavalent chromium concentration Range (0,012 – 10) mg/l |
Spectrophotometric method | PN-77/C-04604.08 | |
| 27 | Wastewater | Anion concentrations: sulfates (2,0 – 1000) mg/l chlorides (2,0 – 1000) mg/l nitrate nitrogen (0,050 – 50) mg/l nitrates (0,20-220) mg/l |
Ion chromatography with conductometric detection (IC-CD) | PN-EN ISO 10304-1:2009+AC:2012 | |
| Pracownia w Zielonej Górze | |||||
| 28 | Water | Colour Range (5 – 100) mg/l Pt |
Spectrophotometric method | PN-EN ISO 7887:2012 metoda C | |
| 29 | Water | Orthophosphate concentration Range (0,005 – 6,6) mg/l PPO4 Range (0,015 – 20,0) mg/l PO43- |
Spectrophotometric method | PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010 | |
| 30 | Water | Metal concentrations copper (1,0 – 50) µg/l selenium (1,0 – 50) µg/l arsenic (1,0 – 50) µg/l silver (1,0 – 50) µg/l nickel (1,0 – 50) µg/l lead (0,5 – 10) µg/l chromium (0,5 – 10) µg/l antimony (0,5 – 10) µg/l cadmium (0,02 – 10) µg/l molybdenum (1,0 – 10) µg/l aluminium (20 – 250) µg/l zinc (10 – 300) µg/l |
Inductively coupled plasma mass spectrometry (ICP-MS) | PN-EN ISO 17294-2:2024-04 | |
| 31 | Water | Anion concentrations: sulfates (0,5 – 500) mg/l chlorides (0,5 – 1000) mg/l nitrate nitrogen (0,05 – 56,5) mg/l nitrates (0,2 – 250) mg/l fluorides (0,1 – 10,0) mg/l |
Ion chromatography with conductometric detection (IC-CD) | PN-EN ISO 10304-1:2009+AC:2012 | |
| 32 | Water | Concentration of polycyclic aromatic hydrocarbons: fluoranthene (0,001 – 50) µg/l naphthalene (0,001 – 50) µg/l anthracene (0,001 – 50) µg/l benzo(b)fluoranthene (0,0001 – 50) µg/l benzo(k)fluoranthene (0,0001 – 50) µg/l benzo(g,h,i)perylene (0,0001 – 50) µg/l indeno(1,2,3-c,d)pyrene (0,0001 – 50) µg/l dibenzo(a,h)anthracene (0,0001 – 50) µg/l benzo(a)pyrene (0,00005 – 50) µg/l Sum of PAH (calculated) |
High-performance liquid chromatography with fluorescence detection (HPLC-FLD) | PB-117/ZG wydanie 1 z dnia 20.01.2020 r. | |
| 33 | Water | Metal concentrations: boron (0,05 – 5,0) mg/l |
Inductively coupled plasma mass spectrometry (ICP-MS) | PN-EN ISO 17294-2:2024-04 | |
| 34 | Water | Kjeldahl nitrogen concentration Range (0,5 – 100) mg/l |
Spectrophotometric method | PB-95/ZG wydanie 1 z dnia 20.01.2020 r. | |
| 35 | Water | Biochemical oxygen demand - BOD5 Range (0,5 – 6,0) mg/l O2 |
Electrochemical method | PN-EN 1899-2:2002 | |
| 36 | Water, Wastewater | Biochemical oxygen demand - BOD5 Range (3,0 – 6000) mg/l O2 |
Electrochemical method | PN-EN ISO 5815-1:2019-12 | |
| 37 | Water, Wastewater | Nitrite nitrogen concentration Range (0,002 – 2,5) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 38 | Water, Wastewater | Nitrite concentration Range (0,01 – 8,2) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 39 | Water, Wastewater | Total phosphorus concentration Range (0,006 – 14,0) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006 +Ap 1:2010 +Ap2: 2010 | |
| 40 | Water, Wastewater | Chemical oxygen demand - COD-Cr Range (10 – 10000) mg/l O2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 41 | Water, Wastewater | Total nitrogen concentration (calculated) | PB-26/CLB wydanie 1 z dnia 16.01.2026 | ||
| 42 | Water, Wastewater | Total suspended solids (TSS) Range (2,0 – 1000) mg/l |
Gravimetric method | PN-EN 872:2007+Ap1:2007 | |
| 43 | Water, Wastewater | Mercury concentration Range (20 – 500) ng/l |
Metoda atomowej spektrometrii fluorescencyjnej (ASF) | PN-EN ISO 17852:2009 | |
| 44 | Water, Wastewater | Metal concentrations arsenic (0,010 – 10) mg/l cadmium (0,010 – 10) mg/l copper (0,020 – 10) mg/l chromium (0,010 – 10) mg/l nickel (0,010 – 10) mg/l lead (0,010 – 10) mg/l iron (0,010 – 10) mg/l manganese (0,010-10) mg/l zinc (0,050-10) mg/l |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | PN-EN ISO 11885:2009 | |
| 45 | Water, Wastewater | Total phosphorus concentration Range (0,050-20) mg/l |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | PN-EN ISO 11885:2009 | |
| 46 | Water, Wastewater | Ammonium ion concentration Range (0,050 – 25,0) mg/l |
Spectrophotometric method | PN-ISO 7150-1:2002 | |
| 47 | Water, Wastewater | Ammonium nitrogen concentration Range (0,040 – 20,0) mg/l |
Spectrophotometric method | PN-ISO 7150-1:2002 | |
| 48 | Water, Wastewater | Formaldehyde concentration Range (0,015 – 1,00) mg/l |
Spectrophotometric method | PB-114/ZG wydanie 1 z dnia 04.01.2021 | na podstawie testu kuwetowego Hach Lange nr LCS 325 | |
| 49 | Water, Wastewater | Kjeldahl nitrogen concentration Range (1,0 – 500) mg/l |
Titrimetric method | PN-EN 25663:2001 | |
| 50 | Water, Wastewater | Mineral oil index Range (0,05 – 100) mg/l |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN ISO 9377-2:2003 | |
| 51 | Soil | pH Range 2,0 – 11,0 |
Potentiometric method | PN-EN ISO 10390:2022-09 | |
| 52 | Soil | Dry matter/water content Range (1,0 – 99) % |
Gravimetric method | PN-EN ISO 11465:2026-03 Metoda A | |
| 53 | Soil | Metal content: cadmium (1,0-20) mg/kg copper (20 – 1000) mg/kg chromium (50 – 2000) mg/kg nickel (20 – 1000) mg/kg lead (40 – 1000) mg/kg zinc (50 – 2500) mg/kg |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | PN-EN ISO 11885:2009 | PN-EN ISO 54321:2021-07 | |
| 54 | Soil | Zawartość węglowodorów ropopochodnych od C12 do C35 Range (30,0 – 10000) mg/kg |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN ISO 16703:2011 | |
| 55 | Soil | Polycyclic aromatic hydrocarbons (PAH) content Anthracene Fluoranthene Benzo(a)anthracene Benzo(b)fluoranthene Benzo(k)fluoranthene Benzo(a)pyrene Dibenzo(a,h)anthracene Indeno(123-cd)piren Chrysene Phenanthrene Benzo(g,h,i)perylene Range (0,020 – 10) mg/kg Naphthalene Range (0,20 – 10) mg/kg Sum of PAH (calculated) |
High-performance liquid chromatography with fluorescence detection (HPLC-FLD) | PN-ISO 13877:2004 | |
| 56 | Wastewater | Anion concentrations chlorides (1,0 – 1000) mg/l sulfates (1,0 – 1000) mg/l nitrates (1,0 – 500) mg/l nitrate nitrogen (0,2 – 115) mg/l |
Ion chromatography with conductometric detection (IC-CD) | PN-EN ISO 10304-1:2009+AC:2012 | |
| 57 | Sewage sludge | Metal content copper (50 – 2500) mg/kg cadmium (10 – 100) mg/kg chromium (100 – 3000) mg/kg nickel (50 – 2000) mg/kg lead (100 – 2000) mg/kg zinc (100 – 5000) mg/kg calcium (0,05-20) % magnesium (0,01-10) % |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | PN-EN ISO 54321:2021-07 | PN-EN ISO 22036:2024-07 | |
| 58 | Sewage sludge | pH Range 2,0 – 11,0 |
Potentiometric method | PN-EN ISO 10390:2022-09 | |
| 59 | Sewage sludge | Dry residue / water content Range (1,0 – 99) % |
Gravimetric method | PN-EN ISO 11465:2026-03 Metoda A | |
| 60 | Sewage sludge | Loss on ignition of dry matter (LOI) Range (10,0 – 90,0)% |
Gravimetric method | PN-EN ISO 15935:2022-01 z wyłączeniem pkt 7.4 i 8.2 | |
| 61 | Sewage sludge | Total phosphorus content Range (1,5 – 50,0) g/kg |
Spectrophotometric method | PN-EN 14672:2006 | PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010 | |
| 62 | Sewage sludge | Total Kjeldahl nitrogen content Range (1,0 – 100) g/kg |
Titrimetric method | PN-EN 13342:2002 | PN-EN 25663:2001 | |
| 63 | Waste code O): 19 08 05 | Metal content copper (50 – 2500) mg/kg cadmium (10 – 100) mg/kg chromium (100 – 3000) mg/kg nickel (50 – 2000) mg/kg lead (100 – 2000) mg/kg zinc (100 – 5000) mg/kg calcium (0,05-20) % magnesium (0,01-10) % Regulated area: Badania wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie stosowania komunalnych osadów ściekowych (tekst jednolity Dz. U. 2023, poz. 23) O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | PN-EN ISO 54321:2021-07 | PN-EN ISO 22036:2024-07 | |
| 64 | Waste code O): 19 08 05 | pH Range 2,0 – 11,0 Regulated area: Badania wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie stosowania komunalnych osadów ściekowych (tekst jednolity Dz. U. 2023, poz. 23) O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
Potentiometric method | PN-EN ISO 10390:2022-09 | |
| 65 | Waste code O): 19 08 05 | Dry residue / water content Range (1,0 – 99) % Regulated area: Badania wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie stosowania komunalnych osadów ściekowych (tekst jednolity Dz. U. 2023, poz. 23) O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
Gravimetric method | PN-EN ISO 11465:2026-03 Metoda A | |
| 66 | Waste code O): 19 08 05 | Loss on ignition of dry matter (LOI) Range (10,0 – 90,0)% Regulated area: Badania wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie stosowania komunalnych osadów ściekowych (tekst jednolity Dz. U. 2023, poz. 23) O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
Gravimetric method | PN-EN ISO 15935:2022-01 z wyłączeniem pkt 7.4 i 8.2 | |
| 67 | Waste code O): 19 08 05 | Total phosphorus content Range (1,5 – 50,0) g/kg Regulated area: Badania wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie stosowania komunalnych osadów ściekowych (tekst jednolity Dz. U. 2023, poz. 23) O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
Spectrophotometric method | PN-EN 14672:2006 | PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010 | |
| 68 | Waste code O): 19 08 05 | Total Kjeldahl nitrogen content Range (1,0 – 100) g/kg Regulated area: Badania wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie stosowania komunalnych osadów ściekowych (tekst jednolity Dz. U. 2023, poz. 23) O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
Titrimetric method | PN-EN 13342:2002 | PN-EN 25663:2001 | |
| Pracownia Terenowa | |||||
| 69 | Water | Sampling for chemical and physical testing | PN-ISO 5667-4:2017-10 | PN-EN ISO 5667-6:2016-12 (z wyłączeniem p. 7.5.) | PN-ISO 5667-11:2017-10 (z wyłączeniem p.5.2) | ||
| 70 | Water | Temperature Range (0,0 – 50,0) ºC |
PN-77/C-04584 | ||
| 71 | Water | Dissolved oxygen concentration Range (0,5-19,9) mg/l O2 |
Electrochemical method | PN-EN ISO 5814:2013-04 | |
| 72 | Water | Dissolved oxygen concentration Range (0,5-19,9) mg/l O2 |
Optical method | ISO 17289:2014 | |
| 73 | Water | Electrical conductivity Range (10-20000) µS/cm |
Conductometric method | PN-EN 27888:1999 | |
| 74 | Wastewater | Sampling for chemical and physical testing | Manual and automatic method | PN-ISO 5667-10:2021-11 | |
| 75 | Wastewater | Temperature Range (0,0 – 50,0) ºC |
PN-77/C-04584 | ||
| 76 | Water, Wastewater | pH Range 2,0-12,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 77 | Soil | Sampling for chemical and physical testing | PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009 | ||
| 78 | Sewage sludge | Sampling for chemical, physical, microbiological and parasitological testing | PN-EN ISO 5667-13:2011 z wyłączeniem p. 6.3.4, p.6.3.5, p.6.3.10 | ||
| 79 | General environment – noise from installations, equipment and industrial plants | A-weighted equivalent sound pressure level Range (30 – 130) dB |
Direct measurement method | Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz. U. z 2023 r., poz. 1706) z wyłączeniem punktu F | |
| 80 | General environment – noise from installations, equipment and industrial plants | A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) | Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz. U. z 2023 r., poz. 1706) z wyłączeniem punktu F | ||
| 81 | Waste code O): 19 08 05 | Sampling for chemical, physical, microbiological and parasitological testing Regulated area: Badania wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie stosowania komunalnych osadów ściekowych (tekst jednolity Dz. U. 2023, poz. 23) O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
PN-EN ISO 5667-13:2011 z wyłączeniem p. 6.3.4, p.6.3.5, p.6.3.10 | ||
| 82 | Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) | Electric field strength: - w zakresie częstotliwości od 80 MHz do 60000 MHz Range (0,5 – 200) V/m Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska |
Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) | |
| 83 | Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) | Magnetic field strength: - w zakresie częstotliwości od 80 MHz do 60000 MHz (calculated) Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska |
Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) | ||
Reference standards (62)
ISO 17289:2014
PB-114/ZG wydanie 1 z dnia 04.01.2021
PB-117/ZG wydanie 1 z dnia 20.01.2020 r.
PB-26/CLB wydanie 1 z dnia 16.01.2026
PB-26/CLB wydanie 1 z dnia 16.01.2026 r.
PB-36/ZG wydanie 1 z dnia 10.01.2020 r.
PB-69/ZG wydanie 1 z dnia 10.01.2020 r.
PB-95/ZG wydanie 1 z dnia 20.01.2020 r.
PN-77/C-04584
PN-77/C-04604.08
PN-EN 13342:2002
PN-EN 14672:2006
PN-EN 1484:1999
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN 903:2002
PN-EN ISO 10304-1:2009+AC:2012
PN-EN ISO 10390:2022-09
PN-EN ISO 10523:2012
PN-EN ISO 11465:2026-03 Metoda A
PN-EN ISO 11885:2009
PN-EN ISO 15681-2:2019-02
PN-EN ISO 15935:2022-01 z wyłączeniem pkt 7.4 i 8.2
PN-EN ISO 16703:2011
PN-EN ISO 17294-2:2024-04
PN-EN ISO 17852:2009
PN-EN ISO 18724:2026-04
PN-EN ISO 22036:2024-07
PN-EN ISO 54321:2021-07
PN-EN ISO 5667-13:2011 z wyłączeniem p. 6.3.4, p.6.3.5, p.6.3.10
PN-EN ISO 5667-6:2016-12 (z wyłączeniem p. 7.5.)
PN-EN ISO 5814:2013-04
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6878:2006 +Ap 1:2010 +Ap2: 2010
PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010
PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 p. 4
PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 p. 7
PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010
PN-EN ISO 7887:2012 metoda C
PN-EN ISO 7887:2012, metoda C
PN-EN ISO 8467:2001
PN-EN ISO 9377-2:2003
PN-EN ISO 9963-1:2001+Ap1:2004
PN-ISO 10381-4:2007
PN-ISO 10381-5:2009
PN-ISO 13877:2004
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 5667-11:2017-10 (z wyłączeniem p.5.2)
PN-ISO 5667-4:2017-10
PN-ISO 6058:1999
PN-ISO 6059:1999
PN-ISO 6439:1994
PN-ISO 7150-1:2002
Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)
Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz. U. z 2023 r., poz. 1706) z wyłączeniem punktu F
na podstawie testu kuwetowego HACH LANGE nr 8027
na podstawie testu kuwetowego Hach Lange nr LCS 325