🇵🇱 GŁÓWNY INSPEKTORAT OCHRONY ŚRODOWISKA PL

PCA AB 127 • Warszawa, Poland • 83 methods

Water & wastewaterEnvironmentMaterials & polymers

GŁÓWNY INSPEKTORAT OCHRONY ŚRODOWISKA is a laboratory accredited by PCA under number AB 127 (Warszawa, Poland). Its accreditation scope covers 83 test methods in the following areas: Water & wastewater, Environment, Materials & polymers. Test objects include: Water, Wastewater, Water, Sewage sludge, Waste code O): 19 08 05. Most frequently used techniques: Spectrophotometric method, Titrimetric method, Gravimetric method.

At a glance

  • Accreditation number: PCA AB 127
  • Methods in scope: 83
  • Types of test objects: 8
  • Techniques used: 17
  • City: Warszawa, Poland
Accreditation number
AB 127
Accreditation body
PCA
Address
ul. Chmielna 132/134, 00-805 Warszawa, CENTRALNE LABORATORIUM BADAWCZE, ODDZIAŁ W ZIELONEJ GÓRZE
City
Warszawa, Poland

What this laboratory tests (8)

Analytical techniques used (17)

Laboratory sections (3)

Laboratory locations

Accreditation scope — test methods (83)

No. Test object Methodology / Parameters Technique Reference document
Pracownia w Gorzowie Wielkopolskim
1 Water Total content of calcium and magnesium (total hardness)
Range (2,5 – 500) mg/l CaCO3
Titrimetric method PN-ISO 6059:1999
2 Water Cyanide concentration
Range (0,007 − 0,200) mg/l
Spectrophotometric method PB-69/ZG wydanie 1 z dnia 10.01.2020 r. | na podstawie testu kuwetowego HACH LANGE nr 8027
3 Water Stężenie chromu sześciowartościowego rozpuszczonego
Range (0,006 – 2,0) mg/l
Spectrophotometric method PN-EN ISO 18724:2026-04
4 Water Calcium concentration
Range (2,0 – 200) mg/l Ca
Titrimetric method PN-ISO 6058:1999
5 Water Colour
Range (5 – 100) mg/l Pt
Spectrophotometric method PN-EN ISO 7887:2012, metoda C
6 Water Total alkalinity
Range (10,0– 250) mg/l CaCO3 Range (0,2 – 5,0) mmol/l
Titrimetric method PN-EN ISO 9963-1:2001+Ap1:2004
7 Water Permanganate index
Range (0,6 – 60) mg/l
Titrimetric method PN-EN ISO 8467:2001
8 Water Stężenie ogólnego węgla organicznego i rozpuszczonego
Range (1,8 – 400) mg/l
Infrared spectrometry method (IR) PN-EN 1484:1999
9 Water Anion concentrations:
sulfates (2,0 – 1000) mg/l chlorides (2,0 – 1000) mg/l nitrate nitrogen (0,050 – 50) mg/l nitrates (0,20-220) mg/l fluorides (0,050-2,0) mg/l
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012
10 Water Biochemical oxygen demand - BOD5
Range (0,44 – 6) mg/l O2
Electrochemical method PN-EN 1899-2:2002
11 Water, Wastewater Ammonium ion concentration
Range (4,12 – 1288) mg/l Ammonium nitrogen concentration Range (3,2 – 1000) mg/l
Titrimetric method PN-ISO 5664:2002
12 Water, Wastewater Nitrite nitrogen concentration
Range (0,001 – 6,0) mg/l Nitrite concentration Range (0,003 – 20,0) mg/l
Spectrophotometric method PN-EN 26777:1999
13 Water, Wastewater Total nitrogen concentration (calculated) PB-26/CLB wydanie 1 z dnia 16.01.2026 r.
14 Water, Wastewater Kjeldahl nitrogen concentration
Range (0,25 – 10) mg/l
Spectrophotometric method PN-EN 25663:2001
15 Water, Wastewater Kjeldahl nitrogen concentration
Range (3,2 – 1000) mg/l
Titrimetric method PN-EN 25663:2001
16 Water, Wastewater Dissolved orthophosphate concentration
Range (0,018 – 18) mg/l PO4
Spectrophotometric method PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 p. 4
17 Water, Wastewater Total phosphorus concentration
Range (0,018 – 25) mg/l
Spectrophotometric method PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 p. 7
18 Water, Wastewater Total phosphorus concentration
Range (0,10-10) mg/l
Continuous flow analysis (CFA) with spectrophotometric detection PN-EN ISO 15681-2:2019-02
19 Water, Wastewater Concentration of substances extractable with petroleum ether
Range (11,5 – 1600) mg/l
Gravimetric method PB-36/ZG wydanie 1 z dnia 10.01.2020 r.
20 Water, Wastewater Phenol index
Range (0,001 – 0,50) mg/l
Spectrophotometric method PN-ISO 6439:1994
21 Water, Wastewater Anionic detergent concentration
Range (0,06 – 48,4) mg/l
Spectrophotometric method PN-EN 903:2002
22 Water, Wastewater Ammonium ion concentration
Range (0,021 – 13) mg/l Ammonium nitrogen concentration Range (0,016 – 10) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
23 Water, Wastewater Total suspended solids (TSS)
Range (3,0 – 5500) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
24 Water, Wastewater Biochemical oxygen demand - BOD5
Range (3,0 – 6000) mg/l O2
Electrochemical method PN-EN ISO 5815-1:2019-12
25 Water, Wastewater Chemical oxygen demand - COD-Cr
Range (10 – 1000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
26 Wastewater Hexavalent chromium concentration
Range (0,012 – 10) mg/l
Spectrophotometric method PN-77/C-04604.08
27 Wastewater Anion concentrations:
sulfates (2,0 – 1000) mg/l chlorides (2,0 – 1000) mg/l nitrate nitrogen (0,050 – 50) mg/l nitrates (0,20-220) mg/l
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012
Pracownia w Zielonej Górze
28 Water Colour
Range (5 – 100) mg/l Pt
Spectrophotometric method PN-EN ISO 7887:2012 metoda C
29 Water Orthophosphate concentration
Range (0,005 – 6,6) mg/l PPO4 Range (0,015 – 20,0) mg/l PO43-
Spectrophotometric method PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010
30 Water Metal concentrations
copper (1,0 – 50) µg/l selenium (1,0 – 50) µg/l arsenic (1,0 – 50) µg/l silver (1,0 – 50) µg/l nickel (1,0 – 50) µg/l lead (0,5 – 10) µg/l chromium (0,5 – 10) µg/l antimony (0,5 – 10) µg/l cadmium (0,02 – 10) µg/l molybdenum (1,0 – 10) µg/l aluminium (20 – 250) µg/l zinc (10 – 300) µg/l
Inductively coupled plasma mass spectrometry (ICP-MS) PN-EN ISO 17294-2:2024-04
31 Water Anion concentrations:
sulfates (0,5 – 500) mg/l chlorides (0,5 – 1000) mg/l nitrate nitrogen (0,05 – 56,5) mg/l nitrates (0,2 – 250) mg/l fluorides (0,1 – 10,0) mg/l
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012
32 Water Concentration of polycyclic aromatic hydrocarbons:
fluoranthene (0,001 – 50) µg/l naphthalene (0,001 – 50) µg/l anthracene (0,001 – 50) µg/l benzo(b)fluoranthene (0,0001 – 50) µg/l benzo(k)fluoranthene (0,0001 – 50) µg/l benzo(g,h,i)perylene (0,0001 – 50) µg/l indeno(1,2,3-c,d)pyrene (0,0001 – 50) µg/l dibenzo(a,h)anthracene (0,0001 – 50) µg/l benzo(a)pyrene (0,00005 – 50) µg/l Sum of PAH (calculated)
High-performance liquid chromatography with fluorescence detection (HPLC-FLD) PB-117/ZG wydanie 1 z dnia 20.01.2020 r.
33 Water Metal concentrations:
boron (0,05 – 5,0) mg/l
Inductively coupled plasma mass spectrometry (ICP-MS) PN-EN ISO 17294-2:2024-04
34 Water Kjeldahl nitrogen concentration
Range (0,5 – 100) mg/l
Spectrophotometric method PB-95/ZG wydanie 1 z dnia 20.01.2020 r.
35 Water Biochemical oxygen demand - BOD5
Range (0,5 – 6,0) mg/l O2
Electrochemical method PN-EN 1899-2:2002
36 Water, Wastewater Biochemical oxygen demand - BOD5
Range (3,0 – 6000) mg/l O2
Electrochemical method PN-EN ISO 5815-1:2019-12
37 Water, Wastewater Nitrite nitrogen concentration
Range (0,002 – 2,5) mg/l
Spectrophotometric method PN-EN 26777:1999
38 Water, Wastewater Nitrite concentration
Range (0,01 – 8,2) mg/l
Spectrophotometric method PN-EN 26777:1999
39 Water, Wastewater Total phosphorus concentration
Range (0,006 – 14,0) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 +Ap 1:2010 +Ap2: 2010
40 Water, Wastewater Chemical oxygen demand - COD-Cr
Range (10 – 10000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
41 Water, Wastewater Total nitrogen concentration (calculated) PB-26/CLB wydanie 1 z dnia 16.01.2026
42 Water, Wastewater Total suspended solids (TSS)
Range (2,0 – 1000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
43 Water, Wastewater Mercury concentration
Range (20 – 500) ng/l
Metoda atomowej spektrometrii fluorescencyjnej (ASF) PN-EN ISO 17852:2009
44 Water, Wastewater Metal concentrations
arsenic (0,010 – 10) mg/l cadmium (0,010 – 10) mg/l copper (0,020 – 10) mg/l chromium (0,010 – 10) mg/l nickel (0,010 – 10) mg/l lead (0,010 – 10) mg/l iron (0,010 – 10) mg/l manganese (0,010-10) mg/l zinc (0,050-10) mg/l
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009
45 Water, Wastewater Total phosphorus concentration
Range (0,050-20) mg/l
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009
46 Water, Wastewater Ammonium ion concentration
Range (0,050 – 25,0) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
47 Water, Wastewater Ammonium nitrogen concentration
Range (0,040 – 20,0) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
48 Water, Wastewater Formaldehyde concentration
Range (0,015 – 1,00) mg/l
Spectrophotometric method PB-114/ZG wydanie 1 z dnia 04.01.2021 | na podstawie testu kuwetowego Hach Lange nr LCS 325
49 Water, Wastewater Kjeldahl nitrogen concentration
Range (1,0 – 500) mg/l
Titrimetric method PN-EN 25663:2001
50 Water, Wastewater Mineral oil index
Range (0,05 – 100) mg/l
Gas chromatography with flame ionization detection (GC-FID) PN-EN ISO 9377-2:2003
51 Soil pH
Range 2,0 – 11,0
Potentiometric method PN-EN ISO 10390:2022-09
52 Soil Dry matter/water content
Range (1,0 – 99) %
Gravimetric method PN-EN ISO 11465:2026-03 Metoda A
53 Soil Metal content:
cadmium (1,0-20) mg/kg copper (20 – 1000) mg/kg chromium (50 – 2000) mg/kg nickel (20 – 1000) mg/kg lead (40 – 1000) mg/kg zinc (50 – 2500) mg/kg
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009 | PN-EN ISO 54321:2021-07
54 Soil Zawartość węglowodorów ropopochodnych od C12 do C35
Range (30,0 – 10000) mg/kg
Gas chromatography with flame ionization detection (GC-FID) PN-EN ISO 16703:2011
55 Soil Polycyclic aromatic hydrocarbons (PAH) content
Anthracene Fluoranthene Benzo(a)anthracene Benzo(b)fluoranthene Benzo(k)fluoranthene Benzo(a)pyrene Dibenzo(a,h)anthracene Indeno(123-cd)piren Chrysene Phenanthrene Benzo(g,h,i)perylene Range (0,020 – 10) mg/kg Naphthalene Range (0,20 – 10) mg/kg Sum of PAH (calculated)
High-performance liquid chromatography with fluorescence detection (HPLC-FLD) PN-ISO 13877:2004
56 Wastewater Anion concentrations
chlorides (1,0 – 1000) mg/l sulfates (1,0 – 1000) mg/l nitrates (1,0 – 500) mg/l nitrate nitrogen (0,2 – 115) mg/l
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012
57 Sewage sludge Metal content
copper (50 – 2500) mg/kg cadmium (10 – 100) mg/kg chromium (100 – 3000) mg/kg nickel (50 – 2000) mg/kg lead (100 – 2000) mg/kg zinc (100 – 5000) mg/kg calcium (0,05-20) % magnesium (0,01-10) %
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 54321:2021-07 | PN-EN ISO 22036:2024-07
58 Sewage sludge pH
Range 2,0 – 11,0
Potentiometric method PN-EN ISO 10390:2022-09
59 Sewage sludge Dry residue / water content
Range (1,0 – 99) %
Gravimetric method PN-EN ISO 11465:2026-03 Metoda A
60 Sewage sludge Loss on ignition of dry matter (LOI)
Range (10,0 – 90,0)%
Gravimetric method PN-EN ISO 15935:2022-01 z wyłączeniem pkt 7.4 i 8.2
61 Sewage sludge Total phosphorus content
Range (1,5 – 50,0) g/kg
Spectrophotometric method PN-EN 14672:2006 | PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010
62 Sewage sludge Total Kjeldahl nitrogen content
Range (1,0 – 100) g/kg
Titrimetric method PN-EN 13342:2002 | PN-EN 25663:2001
63 Waste code O): 19 08 05 Metal content
copper (50 – 2500) mg/kg cadmium (10 – 100) mg/kg chromium (100 – 3000) mg/kg nickel (50 – 2000) mg/kg lead (100 – 2000) mg/kg zinc (100 – 5000) mg/kg calcium (0,05-20) % magnesium (0,01-10) %
Regulated area: Badania wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie stosowania komunalnych osadów ściekowych (tekst jednolity Dz. U. 2023, poz. 23) O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 54321:2021-07 | PN-EN ISO 22036:2024-07
64 Waste code O): 19 08 05 pH
Range 2,0 – 11,0
Regulated area: Badania wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie stosowania komunalnych osadów ściekowych (tekst jednolity Dz. U. 2023, poz. 23) O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów
Potentiometric method PN-EN ISO 10390:2022-09
65 Waste code O): 19 08 05 Dry residue / water content
Range (1,0 – 99) %
Regulated area: Badania wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie stosowania komunalnych osadów ściekowych (tekst jednolity Dz. U. 2023, poz. 23) O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów
Gravimetric method PN-EN ISO 11465:2026-03 Metoda A
66 Waste code O): 19 08 05 Loss on ignition of dry matter (LOI)
Range (10,0 – 90,0)%
Regulated area: Badania wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie stosowania komunalnych osadów ściekowych (tekst jednolity Dz. U. 2023, poz. 23) O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów
Gravimetric method PN-EN ISO 15935:2022-01 z wyłączeniem pkt 7.4 i 8.2
67 Waste code O): 19 08 05 Total phosphorus content
Range (1,5 – 50,0) g/kg
Regulated area: Badania wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie stosowania komunalnych osadów ściekowych (tekst jednolity Dz. U. 2023, poz. 23) O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów
Spectrophotometric method PN-EN 14672:2006 | PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010
68 Waste code O): 19 08 05 Total Kjeldahl nitrogen content
Range (1,0 – 100) g/kg
Regulated area: Badania wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie stosowania komunalnych osadów ściekowych (tekst jednolity Dz. U. 2023, poz. 23) O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów
Titrimetric method PN-EN 13342:2002 | PN-EN 25663:2001
Pracownia Terenowa
69 Water Sampling for chemical and physical testing PN-ISO 5667-4:2017-10 | PN-EN ISO 5667-6:2016-12 (z wyłączeniem p. 7.5.) | PN-ISO 5667-11:2017-10 (z wyłączeniem p.5.2)
70 Water Temperature
Range (0,0 – 50,0) ºC
PN-77/C-04584
71 Water Dissolved oxygen concentration
Range (0,5-19,9) mg/l O2
Electrochemical method PN-EN ISO 5814:2013-04
72 Water Dissolved oxygen concentration
Range (0,5-19,9) mg/l O2
Optical method ISO 17289:2014
73 Water Electrical conductivity
Range (10-20000) µS/cm
Conductometric method PN-EN 27888:1999
74 Wastewater Sampling for chemical and physical testing Manual and automatic method PN-ISO 5667-10:2021-11
75 Wastewater Temperature
Range (0,0 – 50,0) ºC
PN-77/C-04584
76 Water, Wastewater pH
Range 2,0-12,0
Potentiometric method PN-EN ISO 10523:2012
77 Soil Sampling for chemical and physical testing PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009
78 Sewage sludge Sampling for chemical, physical, microbiological and parasitological testing PN-EN ISO 5667-13:2011 z wyłączeniem p. 6.3.4, p.6.3.5, p.6.3.10
79 General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level
Range (30 – 130) dB
Direct measurement method Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz. U. z 2023 r., poz. 1706) z wyłączeniem punktu F
80 General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz. U. z 2023 r., poz. 1706) z wyłączeniem punktu F
81 Waste code O): 19 08 05 Sampling for chemical, physical, microbiological and parasitological testing
Regulated area: Badania wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie stosowania komunalnych osadów ściekowych (tekst jednolity Dz. U. 2023, poz. 23) O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów
PN-EN ISO 5667-13:2011 z wyłączeniem p. 6.3.4, p.6.3.5, p.6.3.10
82 Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Electric field strength:
- w zakresie częstotliwości od 80 MHz do 60000 MHz Range (0,5 – 200) V/m
Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska
Direct measurement method Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)
83 Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Magnetic field strength:
- w zakresie częstotliwości od 80 MHz do 60000 MHz (calculated)
Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska
Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)

Reference standards (62)

ISO 17289:2014
PB-114/ZG wydanie 1 z dnia 04.01.2021
PB-117/ZG wydanie 1 z dnia 20.01.2020 r.
PB-26/CLB wydanie 1 z dnia 16.01.2026
PB-26/CLB wydanie 1 z dnia 16.01.2026 r.
PB-36/ZG wydanie 1 z dnia 10.01.2020 r.
PB-69/ZG wydanie 1 z dnia 10.01.2020 r.
PB-95/ZG wydanie 1 z dnia 20.01.2020 r.
PN-77/C-04584
PN-77/C-04604.08
PN-EN 13342:2002
PN-EN 14672:2006
PN-EN 1484:1999
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN 903:2002
PN-EN ISO 10304-1:2009+AC:2012
PN-EN ISO 10390:2022-09
PN-EN ISO 10523:2012
PN-EN ISO 11465:2026-03 Metoda A
PN-EN ISO 11885:2009
PN-EN ISO 15681-2:2019-02
PN-EN ISO 15935:2022-01 z wyłączeniem pkt 7.4 i 8.2
PN-EN ISO 16703:2011
PN-EN ISO 17294-2:2024-04
PN-EN ISO 17852:2009
PN-EN ISO 18724:2026-04
PN-EN ISO 22036:2024-07
PN-EN ISO 54321:2021-07
PN-EN ISO 5667-13:2011 z wyłączeniem p. 6.3.4, p.6.3.5, p.6.3.10
PN-EN ISO 5667-6:2016-12 (z wyłączeniem p. 7.5.)
PN-EN ISO 5814:2013-04
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6878:2006 +Ap 1:2010 +Ap2: 2010
PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010
PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 p. 4
PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 p. 7
PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010
PN-EN ISO 7887:2012 metoda C
PN-EN ISO 7887:2012, metoda C
PN-EN ISO 8467:2001
PN-EN ISO 9377-2:2003
PN-EN ISO 9963-1:2001+Ap1:2004
PN-ISO 10381-4:2007
PN-ISO 10381-5:2009
PN-ISO 13877:2004
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 5667-11:2017-10 (z wyłączeniem p.5.2)
PN-ISO 5667-4:2017-10
PN-ISO 6058:1999
PN-ISO 6059:1999
PN-ISO 6439:1994
PN-ISO 7150-1:2002
Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)
Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz. U. z 2023 r., poz. 1706) z wyłączeniem punktu F
na podstawie testu kuwetowego HACH LANGE nr 8027
na podstawie testu kuwetowego Hach Lange nr LCS 325