{"lab":{"_id":"69ad52a3de79e566650fb12d","accr_number":"AB 127","country":"PL","accr_body":"PCA","address":"ul. Chmielna 132/134, 00-805 Warszawa, CENTRALNE LABORATORIUM BADAWCZE, ODDZIAŁ W ZIELONEJ GÓRZE","categories":["water","environment","materials"],"city":"Warszawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":83,"name":"GŁÓWNY INSPEKTORAT OCHRONY ŚRODOWISKA","parse_status":"parsed","parse_version":3,"pdf_files":["AB_127.pdf"],"scope_summary":"","search_text":"główny inspektorat ochrony środowiska ul. chmielna 132/134, 00-805 warszawa, centralne laboratorium badawcze, oddział w zielonej górze water other pharma electronics materials food petro environment metrology","status":"active","updated_at":"2026-03-08T14:50:26.517Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T10:08:33.520Z","email_confidence":"high","email_mx":true,"email_source":"https://www.gov.pl/web/gios/centralne-laboratorium-badawcze","parse_date":"2026-08-17T10:08:33.520Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"C/28/P, C/30/P, C/31/P, C/32/P","pl":"Badania chemiczne i pobieranie próbek wody, ścieków, gleby, osadów ściekowych, odpadów","en":"Chemical tests and sampling of water, sewage, soil, sediments, waste"},{"codes":"G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko ogólne (czynniki fizyczne – hałas, pole elektromagnetyczne)","en":"Tests concerning environmental engineering (environmental and climatic) – general environment (physical factors – noise, electromagnetic field)"},{"codes":"N/28/P, N/30/P, N/31/P, N/32/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, ścieków, gleby, osadów ściekowych, odpadów","en":"Tests of physical properties and sampling of water, sewage, soil, sediments, waste"}],"issue":{"no":"28","date":"23.06.2026"},"map_coord":[52.227738,20.992749],"map_geo":"nominatim-street","lab_locations":[{"name":"CENTRALNE LABORATORIUM BADAWCZE ODDZIAŁ W ZIELONEJ GÓRZE","address":"ul. Siemiradzkiego 19","city":"Zielona Góra","postal":"65-231"},{"name":"Pracownia w Gorzowie Wielkopolskim","address":"ul. Kostrzyńska 48, 66-400 Gorzów Wielkopolski","city":"Gorzów Wielkopolski","postal":"66-400"},{"name":"Pracownia w Zielonej Górze","address":"ul. Siemiradzkiego 19, 65-231 Zielona Góra","city":"Zielona Góra","postal":"65-231"},{"name":"Pracownia Terenowa","address":"ul. Siemiradzkiego 19, 65-231 Zielona Góra","city":"Zielona Góra","postal":"65-231"}],"scope_format":"PCA::pracownie+siatka5","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/9852acfea1011862b3819f2783f2201e/AB%20127.pdf","has_en":true,"category_counts":{"water":68,"environment":17,"materials":6,"microbiology":2,"petro":1},"category_scores":{"water":49.19,"environment":3.07,"materials":0.38,"microbiology":0.04,"petro":0.01},"has_zh":true},"methods":[{"_id":"6a82dda1884ede9a1b2c3386","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Woda","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","parameters":[{"name":"Zakres","range":"(2,5 – 500) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (2,5 – 500) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":"Pracownia w Gorzowie Wielkopolskim","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (2,5 – 500) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres (2,5 – 500) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total content of calcium and magnesium (total hardness)","parameters_en":[{"name":"Range","range":"(2,5 – 500) mg/l CaCO3"}],"search_en":"Water Total content of calcium and magnesium (total hardness) Titrimetric method Range PN-ISO 6059:1999","technique_en":"Titrimetric method","test_object_en":"Water","methodology_zh":"钙与镁总量（总硬度）","parameters_zh":[{"name":"范围","range":"(2,5 – 500) mg/l CaCO3"}],"search_zh":"水 钙与镁总量（总硬度） 滴定法 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水"},{"_id":"6a82dda1884ede9a1b2c3387","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie cyjanków","parameters":[{"name":"Zakres","range":"(0,007 − 0,200) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie cyjanków\nZakres (0,007 − 0,200) mg/l\nMetoda spektrofotometryczna","reference":"PB-69/ZG wydanie 1 z dnia 10.01.2020 r. | na podstawie testu kuwetowego HACH LANGE nr 8027","norm_bases":["PB-69/ZG wydanie 1 z dnia 10.01.2020 r.","na podstawie testu kuwetowego HACH LANGE nr 8027"],"lab_section":"Pracownia w Gorzowie Wielkopolskim","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie cyjanków\nZakres (0,007 − 0,200) mg/l\nMetoda spektrofotometryczna PB-69/ZG wydanie 1 z dnia 10.01.2020 r. | na podstawie testu kuwetowego HACH LANGE nr 8027 Woda Stezenie cyjankow\nZakres (0,007 − 0,200) mg/l\nMetoda spektrofotometryczna PB-69/ZG wydanie 1 z dnia 10.01.2020 r. | na podstawie testu kuwetowego HACH LANGE nr 8027","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Cyanide concentration","parameters_en":[{"name":"Range","range":"(0,007 − 0,200) mg/l"}],"search_en":"Water Cyanide concentration Spectrophotometric method Range PB-69/ZG wydanie 1 z dnia 10.01.2020 r. | na podstawie testu kuwetowego HACH LANGE nr 8027","technique_en":"Spectrophotometric method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,007 − 0,200) mg/l"}],"search_zh":"水 氰化物浓度 分光光度法 范围 PB-69/ZG wydanie 1 z dnia 10.01.2020 r. | na podstawie testu kuwetowego HACH LANGE nr 8027","technique_zh":"分光光度法","test_object_zh":"水","methodology_zh":"氰化物浓度"},{"_id":"6a82dda1884ede9a1b2c3388","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie chromu sześciowartościowego rozpuszczonego","parameters":[{"name":"Zakres","range":"(0,006 – 2,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chromu sześciowartościowego rozpuszczonego\nZakres (0,006 – 2,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 18724:2026-04","norm_bases":["PN-EN ISO 18724:2026-04"],"lab_section":"Pracownia w Gorzowie Wielkopolskim","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie chromu sześciowartościowego rozpuszczonego\nZakres (0,006 – 2,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 18724:2026-04 Woda Stezenie chromu szesciowartosciowego rozpuszczonego\nZakres (0,006 – 2,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 18724:2026-04","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,006 – 2,0) mg/l"}],"search_en":"Water Spectrophotometric method Range PN-EN ISO 18724:2026-04","technique_en":"Spectrophotometric method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,006 – 2,0) mg/l"}],"search_zh":"水 分光光度法 范围 PN-EN ISO 18724:2026-04","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a82dda1884ede9a1b2c3389","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie wapnia","parameters":[{"name":"Zakres","range":"(2,0 – 200) mg/l Ca"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie wapnia\nZakres (2,0 – 200) mg/l Ca\nMetoda miareczkowa","reference":"PN-ISO 6058:1999","norm_bases":["PN-ISO 6058:1999"],"lab_section":"Pracownia w Gorzowie Wielkopolskim","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie wapnia\nZakres (2,0 – 200) mg/l Ca\nMetoda miareczkowa PN-ISO 6058:1999 Woda Stezenie wapnia\nZakres (2,0 – 200) mg/l Ca\nMetoda miareczkowa PN-ISO 6058:1999","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Calcium concentration","parameters_en":[{"name":"Range","range":"(2,0 – 200) mg/l Ca"}],"search_en":"Water Calcium concentration Titrimetric method Range PN-ISO 6058:1999","technique_en":"Titrimetric method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(2,0 – 200) mg/l Ca"}],"search_zh":"水 钙浓度 滴定法 范围 PN-ISO 6058:1999","technique_zh":"滴定法","test_object_zh":"水","methodology_zh":"钙浓度"},{"_id":"6a82dda1884ede9a1b2c338a","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Woda","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(5 – 100) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa\nZakres (5 – 100) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012, metoda C","norm_bases":["PN-EN ISO 7887:2012, metoda C"],"lab_section":"Pracownia w Gorzowie Wielkopolskim","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Barwa\nZakres (5 – 100) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012, metoda C Woda Barwa\nZakres (5 – 100) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012, metoda C","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(5 – 100) mg/l Pt"}],"search_en":"Water Colour Spectrophotometric method Range PN-EN ISO 7887:2012, metoda C","technique_en":"Spectrophotometric method","test_object_en":"Water","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5 – 100) mg/l Pt"}],"search_zh":"水 色度 分光光度法 范围 PN-EN ISO 7887:2012, metoda C","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a82dda1884ede9a1b2c338b","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Woda","methodology":"Zasadowość ogólna","parameters":[{"name":"Zakres","range":"(10,0– 250) mg/l CaCO3"},{"name":"Zakres","range":"(0,2 – 5,0) mmol/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zasadowość ogólna\nZakres:\nZakres (10,0– 250) mg/l CaCO3\nZakres (0,2 – 5,0) mmol/l\nMetoda miareczkowa","reference":"PN-EN ISO 9963-1:2001+Ap1:2004","norm_bases":["PN-EN ISO 9963-1:2001+Ap1:2004"],"lab_section":"Pracownia w Gorzowie Wielkopolskim","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Zasadowość ogólna\nZakres:\nZakres (10,0– 250) mg/l CaCO3\nZakres (0,2 – 5,0) mmol/l\nMetoda miareczkowa PN-EN ISO 9963-1:2001+Ap1:2004 Woda Zasadowosc ogolna\nZakres:\nZakres (10,0– 250) mg/l CaCO3\nZakres (0,2 – 5,0) mmol/l\nMetoda miareczkowa PN-EN ISO 9963-1:2001+Ap1:2004","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total alkalinity","parameters_en":[{"name":"Range","range":"(10,0– 250) mg/l CaCO3"},{"name":"Range","range":"(0,2 – 5,0) mmol/l"}],"search_en":"Water Total alkalinity Titrimetric method Range Range PN-EN ISO 9963-1:2001+Ap1:2004","technique_en":"Titrimetric method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(10,0– 250) mg/l CaCO3"},{"name":"范围","range":"(0,2 – 5,0) mmol/l"}],"search_zh":"水 总碱度 滴定法 范围 范围 PN-EN ISO 9963-1:2001+Ap1:2004","technique_zh":"滴定法","test_object_zh":"水","methodology_zh":"总碱度"},{"_id":"6a82dda1884ede9a1b2c338c","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Woda","methodology":"Indeks nadmanganianowy","parameters":[{"name":"Zakres","range":"(0,6 – 60) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy\nZakres (0,6 – 60) mg/l\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"Pracownia w Gorzowie Wielkopolskim","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Indeks nadmanganianowy\nZakres (0,6 – 60) mg/l\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda Indeks nadmanganianowy\nZakres (0,6 – 60) mg/l\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Permanganate index","parameters_en":[{"name":"Range","range":"(0,6 – 60) mg/l"}],"search_en":"Water Permanganate index Titrimetric method Range PN-EN ISO 8467:2001","technique_en":"Titrimetric method","test_object_en":"Water","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,6 – 60) mg/l"}],"search_zh":"水 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"水"},{"_id":"6a82dda1884ede9a1b2c338d","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie ogólnego węgla organicznego i rozpuszczonego","parameters":[{"name":"Zakres","range":"(1,8 – 400) mg/l"}],"technique":"Metoda spektrometrii w podczerwieni (IR)","techniques":["Metoda spektrometrii w podczerwieni (IR)"],"computed":[],"activity":"Stężenie ogólnego węgla organicznego i rozpuszczonego\nZakres (1,8 – 400) mg/l\nMetoda spektrometrii w podczerwieni (IR)","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":"Pracownia w Gorzowie Wielkopolskim","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie ogólnego węgla organicznego i rozpuszczonego\nZakres (1,8 – 400) mg/l\nMetoda spektrometrii w podczerwieni (IR) PN-EN 1484:1999 Woda Stezenie ogolnego wegla organicznego i rozpuszczonego\nZakres (1,8 – 400) mg/l\nMetoda spektrometrii w podczerwieni (IR) PN-EN 1484:1999","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(1,8 – 400) mg/l"}],"search_en":"Water Infrared spectrometry method (IR) Range PN-EN 1484:1999","technique_en":"Infrared spectrometry method (IR)","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(1,8 – 400) mg/l"}],"search_zh":"水 红外光谱法（IR） 范围 PN-EN 1484:1999","test_object_zh":"水","technique_zh":"红外光谱法（IR）"},{"_id":"6a82dda1884ede9a1b2c338e","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie anionów:","parameters":[{"name":"siarczany","range":"(2,0 – 1000) mg/l"},{"name":"chlorki","range":"(2,0 – 1000) mg/l"},{"name":"azot azotanowy","range":"(0,050 – 50) mg/l"},{"name":"azotany","range":"(0,20-220) mg/l"},{"name":"fluorki","range":"(0,050-2,0) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów:\nZakres:\nsiarczany (2,0 – 1000) mg/l\nchlorki (2,0 – 1000) mg/l\nazot azotanowy (0,050 – 50) mg/l\nazotany (0,20-220) mg/l\nfluorki (0,050-2,0) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Pracownia w Gorzowie Wielkopolskim","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie anionów:\nZakres:\nsiarczany (2,0 – 1000) mg/l\nchlorki (2,0 – 1000) mg/l\nazot azotanowy (0,050 – 50) mg/l\nazotany (0,20-220) mg/l\nfluorki (0,050-2,0) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda Stezenie anionow:\nZakres:\nsiarczany (2,0 – 1000) mg/l\nchlorki (2,0 – 1000) mg/l\nazot azotanowy (0,050 – 50) mg/l\nazotany (0,20-220) mg/l\nfluorki (0,050-2,0) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anion concentrations:","parameters_en":[{"name":"sulfates","range":"(2,0 – 1000) mg/l"},{"name":"chlorides","range":"(2,0 – 1000) mg/l"},{"name":"nitrate nitrogen","range":"(0,050 – 50) mg/l"},{"name":"nitrates","range":"(0,20-220) mg/l"},{"name":"fluorides","range":"(0,050-2,0) mg/l"}],"search_en":"Water Anion concentrations: Ion chromatography with conductometric detection (IC-CD) sulfates chlorides nitrate nitrogen nitrates fluorides PN-EN ISO 10304-1:2009+AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water","methodology_zh":"阴离子浓度：","search_zh":"水 阴离子浓度： 离子色谱-电导检测法（IC-CD） 硫酸盐 氯化物 硝酸盐氮 硝酸盐 氟化物 PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水","parameters_zh":[{"name":"硫酸盐","range":"(2,0 – 1000) mg/l"},{"name":"氯化物","range":"(2,0 – 1000) mg/l"},{"name":"硝酸盐氮","range":"(0,050 – 50) mg/l"},{"name":"硝酸盐","range":"(0,20-220) mg/l"},{"name":"氟化物","range":"(0,050-2,0) mg/l"}]},{"_id":"6a82dda1884ede9a1b2c338f","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Woda","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","parameters":[{"name":"Zakres","range":"(0,44 – 6) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,44 – 6) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":"Pracownia w Gorzowie Wielkopolskim","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,44 – 6) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,44 – 6) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand - BOD5","parameters_en":[{"name":"Range","range":"(0,44 – 6) mg/l O2"}],"search_en":"Water Biochemical oxygen demand - BOD5 Electrochemical method Range PN-EN 1899-2:2002","technique_en":"Electrochemical method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,44 – 6) mg/l O2"}],"search_zh":"水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a82dda1884ede9a1b2c3390","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie jonu amonowego","parameters":[{"name":"Zakres","range":"(4,12 – 1288) mg/l"},{"name":"Stężenie azotu amonowego"},{"name":"Zakres","range":"(3,2 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie jonu amonowego\nZakres:\nZakres (4,12 – 1288) mg/l\nStężenie azotu amonowego\nZakres (3,2 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":"Pracownia w Gorzowie Wielkopolskim","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie jonu amonowego\nZakres:\nZakres (4,12 – 1288) mg/l\nStężenie azotu amonowego\nZakres (3,2 – 1000) mg/l\nMetoda miareczkowa PN-ISO 5664:2002 Woda, Scieki Stezenie jonu amonowego\nZakres:\nZakres (4,12 – 1288) mg/l\nStezenie azotu amonowego\nZakres (3,2 – 1000) mg/l\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium ion concentration","parameters_en":[{"name":"Range","range":"(4,12 – 1288) mg/l"},{"name":"Ammonium nitrogen concentration"},{"name":"Range","range":"(3,2 – 1000) mg/l"}],"search_en":"Water, Wastewater Ammonium ion concentration Titrimetric method Range Ammonium nitrogen concentration Range PN-ISO 5664:2002","technique_en":"Titrimetric method","test_object_en":"Water, Wastewater","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(4,12 – 1288) mg/l"},{"name":"氨氮浓度"},{"name":"范围","range":"(3,2 – 1000) mg/l"}],"search_zh":"水、污水 铵离子浓度 滴定法 范围 氨氮浓度 范围 PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"水、污水"},{"_id":"6a82dda1884ede9a1b2c3391","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,001 – 6,0) mg/l"},{"name":"Stężenie azotynów"},{"name":"Zakres","range":"(0,003 – 20,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres:\nZakres (0,001 – 6,0) mg/l\nStężenie azotynów\nZakres (0,003 – 20,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Pracownia w Gorzowie Wielkopolskim","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu azotynowego\nZakres:\nZakres (0,001 – 6,0) mg/l\nStężenie azotynów\nZakres (0,003 – 20,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, Scieki Stezenie azotu azotynowego\nZakres:\nZakres (0,001 – 6,0) mg/l\nStezenie azotynow\nZakres (0,003 – 20,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,001 – 6,0) mg/l"},{"name":"Nitrite concentration"},{"name":"Range","range":"(0,003 – 20,0) mg/l"}],"search_en":"Water, Wastewater Nitrite nitrogen concentration Spectrophotometric method Range Nitrite concentration Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,001 – 6,0) mg/l"},{"name":"亚硝酸盐浓度"},{"name":"范围","range":"(0,003 – 20,0) mg/l"}],"search_zh":"水、污水 亚硝态氮浓度 分光光度法 范围 亚硝酸盐浓度 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a82dda1884ede9a1b2c3392","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu ogólnego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PB-26/CLB wydanie 1 z dnia 16.01.2026 r.","norm_bases":["PB-26/CLB wydanie 1 z dnia 16.01.2026 r."],"lab_section":"Pracownia w Gorzowie Wielkopolskim","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu ogólnego (z obliczeń) PB-26/CLB wydanie 1 z dnia 16.01.2026 r. Woda, Scieki Stezenie azotu ogolnego (z obliczen) PB-26/CLB wydanie 1 z dnia 16.01.2026 r.","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration (calculated)","search_en":"Water, Wastewater Total nitrogen concentration (calculated) PB-26/CLB wydanie 1 z dnia 16.01.2026 r.","test_object_en":"Water, Wastewater","methodology_zh":"总氮浓度（计算值）","search_zh":"水、污水 总氮浓度（计算值） PB-26/CLB wydanie 1 z dnia 16.01.2026 r.","test_object_zh":"水、污水"},{"_id":"6a82dda1884ede9a1b2c3393","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(0,25 – 10) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (0,25 – 10) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Pracownia w Gorzowie Wielkopolskim","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu Kjeldahla\nZakres (0,25 – 10) mg/l\nMetoda spektrofotometryczna PN-EN 25663:2001 Woda, Scieki Stezenie azotu Kjeldahla\nZakres (0,25 – 10) mg/l\nMetoda spektrofotometryczna PN-EN 25663:2001","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,25 – 10) mg/l"}],"search_en":"Water, Wastewater Kjeldahl nitrogen concentration Spectrophotometric method Range PN-EN 25663:2001","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(0,25 – 10) mg/l"}],"search_zh":"水、污水 凯氏氮浓度 分光光度法 范围 PN-EN 25663:2001","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a82dda1884ede9a1b2c3394","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(3,2 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (3,2 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Pracownia w Gorzowie Wielkopolskim","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu Kjeldahla\nZakres (3,2 – 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Woda, Scieki Stezenie azotu Kjeldahla\nZakres (3,2 – 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(3,2 – 1000) mg/l"}],"search_en":"Water, Wastewater Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Water, Wastewater","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(3,2 – 1000) mg/l"}],"search_zh":"水、污水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"水、污水"},{"_id":"6a82dda1884ede9a1b2c3395","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie ortofosforanów rozpuszczonych","parameters":[{"name":"Zakres","range":"(0,018 – 18) mg/l PO4"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie ortofosforanów rozpuszczonych\nZakres (0,018 – 18) mg/l PO4\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 p. 4","norm_bases":["PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 p. 4"],"lab_section":"Pracownia w Gorzowie Wielkopolskim","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie ortofosforanów rozpuszczonych\nZakres (0,018 – 18) mg/l PO4\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 p. 4 Woda, Scieki Stezenie ortofosforanow rozpuszczonych\nZakres (0,018 – 18) mg/l PO4\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 p. 4","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved orthophosphate concentration","parameters_en":[{"name":"Range","range":"(0,018 – 18) mg/l PO4"}],"search_en":"Water, Wastewater Dissolved orthophosphate concentration Spectrophotometric method Range PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 p. 4","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(0,018 – 18) mg/l PO4"}],"search_zh":"水、污水 溶解性正磷酸盐浓度 分光光度法 范围 PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 p. 4","technique_zh":"分光光度法","test_object_zh":"水、污水","methodology_zh":"溶解性正磷酸盐浓度"},{"_id":"6a82dda1884ede9a1b2c3396","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,018 – 25) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,018 – 25) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 p. 7","norm_bases":["PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 p. 7"],"lab_section":"Pracownia w Gorzowie Wielkopolskim","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie fosforu ogólnego\nZakres (0,018 – 25) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 p. 7 Woda, Scieki Stezenie fosforu ogolnego\nZakres (0,018 – 25) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 p. 7","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,018 – 25) mg/l"}],"search_en":"Water, Wastewater Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 p. 7","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,018 – 25) mg/l"}],"search_zh":"水、污水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 p. 7","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a82dda1884ede9a1b2c3397","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,10-10) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,10-10) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 15681-2:2019-02","norm_bases":["PN-EN ISO 15681-2:2019-02"],"lab_section":"Pracownia w Gorzowie Wielkopolskim","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie fosforu ogólnego\nZakres (0,10-10) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 15681-2:2019-02 Woda, Scieki Stezenie fosforu ogolnego\nZakres (0,10-10) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 15681-2:2019-02","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,10-10) mg/l"}],"search_en":"Water, Wastewater Total phosphorus concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 15681-2:2019-02","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Water, Wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,10-10) mg/l"}],"search_zh":"水、污水 总磷浓度 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 15681-2:2019-02","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、污水"},{"_id":"6a82dda1884ede9a1b2c3398","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie substancji ekstrahujących się eterem naftowym","parameters":[{"name":"Zakres","range":"(11,5 – 1600) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie substancji ekstrahujących się eterem naftowym\nZakres (11,5 – 1600) mg/l\nMetoda wagowa","reference":"PB-36/ZG wydanie 1 z dnia 10.01.2020 r.","norm_bases":["PB-36/ZG wydanie 1 z dnia 10.01.2020 r."],"lab_section":"Pracownia w Gorzowie Wielkopolskim","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie substancji ekstrahujących się eterem naftowym\nZakres (11,5 – 1600) mg/l\nMetoda wagowa PB-36/ZG wydanie 1 z dnia 10.01.2020 r. Woda, Scieki Stezenie substancji ekstrahujacych sie eterem naftowym\nZakres (11,5 – 1600) mg/l\nMetoda wagowa PB-36/ZG wydanie 1 z dnia 10.01.2020 r.","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of substances extractable with petroleum ether","parameters_en":[{"name":"Range","range":"(11,5 – 1600) mg/l"}],"search_en":"Water, Wastewater Concentration of substances extractable with petroleum ether Gravimetric method Range PB-36/ZG wydanie 1 z dnia 10.01.2020 r.","technique_en":"Gravimetric method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(11,5 – 1600) mg/l"}],"search_zh":"水、污水 石油醚可萃取物浓度 重量法 范围 PB-36/ZG wydanie 1 z dnia 10.01.2020 r.","technique_zh":"重量法","test_object_zh":"水、污水","methodology_zh":"石油醚可萃取物浓度"},{"_id":"6a82dda1884ede9a1b2c3399","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Indeks fenolowy","parameters":[{"name":"Zakres","range":"(0,001 – 0,50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Indeks fenolowy\nZakres (0,001 – 0,50) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6439:1994","norm_bases":["PN-ISO 6439:1994"],"lab_section":"Pracownia w Gorzowie Wielkopolskim","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Indeks fenolowy\nZakres (0,001 – 0,50) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994 Woda, Scieki Indeks fenolowy\nZakres (0,001 – 0,50) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phenol index","parameters_en":[{"name":"Range","range":"(0,001 – 0,50) mg/l"}],"search_en":"Water, Wastewater Phenol index Spectrophotometric method Range PN-ISO 6439:1994","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(0,001 – 0,50) mg/l"}],"search_zh":"水、污水 酚指数 分光光度法 范围 PN-ISO 6439:1994","technique_zh":"分光光度法","test_object_zh":"水、污水","methodology_zh":"酚指数"},{"_id":"6a82dda1884ede9a1b2c339a","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie detergentów anionowych","parameters":[{"name":"Zakres","range":"(0,06 – 48,4) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie detergentów anionowych\nZakres (0,06 – 48,4) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 903:2002","norm_bases":["PN-EN 903:2002"],"lab_section":"Pracownia w Gorzowie Wielkopolskim","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie detergentów anionowych\nZakres (0,06 – 48,4) mg/l\nMetoda spektrofotometryczna PN-EN 903:2002 Woda, Scieki Stezenie detergentow anionowych\nZakres (0,06 – 48,4) mg/l\nMetoda spektrofotometryczna PN-EN 903:2002","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anionic detergent concentration","parameters_en":[{"name":"Range","range":"(0,06 – 48,4) mg/l"}],"search_en":"Water, Wastewater Anionic detergent concentration Spectrophotometric method Range PN-EN 903:2002","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(0,06 – 48,4) mg/l"}],"search_zh":"水、污水 阴离子洗涤剂浓度 分光光度法 范围 PN-EN 903:2002","technique_zh":"分光光度法","test_object_zh":"水、污水","methodology_zh":"阴离子洗涤剂浓度"},{"_id":"6a82dda1884ede9a1b2c339b","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie jonu amonowego","parameters":[{"name":"Zakres","range":"(0,021 – 13) mg/l"},{"name":"Stężenie azotu amonowego"},{"name":"Zakres","range":"(0,016 – 10) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonu amonowego\nZakres:\nZakres (0,021 – 13) mg/l\nStężenie azotu amonowego\nZakres (0,016 – 10) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Pracownia w Gorzowie Wielkopolskim","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie jonu amonowego\nZakres:\nZakres (0,021 – 13) mg/l\nStężenie azotu amonowego\nZakres (0,016 – 10) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, Scieki Stezenie jonu amonowego\nZakres:\nZakres (0,021 – 13) mg/l\nStezenie azotu amonowego\nZakres (0,016 – 10) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium ion concentration","parameters_en":[{"name":"Range","range":"(0,021 – 13) mg/l"},{"name":"Ammonium nitrogen concentration"},{"name":"Range","range":"(0,016 – 10) mg/l"}],"search_en":"Water, Wastewater Ammonium ion concentration Spectrophotometric method Range Ammonium nitrogen concentration Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,021 – 13) mg/l"},{"name":"氨氮浓度"},{"name":"范围","range":"(0,016 – 10) mg/l"}],"search_zh":"水、污水 铵离子浓度 分光光度法 范围 氨氮浓度 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a82dda1884ede9a1b2c339c","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(3,0 – 5500) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (3,0 – 5500) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Pracownia w Gorzowie Wielkopolskim","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Zawiesiny ogólne\nZakres (3,0 – 5500) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, Scieki Zawiesiny ogolne\nZakres (3,0 – 5500) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(3,0 – 5500) mg/l"}],"search_en":"Water, Wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, Wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(3,0 – 5500) mg/l"}],"search_zh":"水、污水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、污水"},{"_id":"6a82dda1884ede9a1b2c339d","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","parameters":[{"name":"Zakres","range":"(3,0 – 6000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (3,0 – 6000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Pracownia w Gorzowie Wielkopolskim","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (3,0 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda, Scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (3,0 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand - BOD5","parameters_en":[{"name":"Range","range":"(3,0 – 6000) mg/l O2"}],"search_en":"Water, Wastewater Biochemical oxygen demand - BOD5 Electrochemical method Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(3,0 – 6000) mg/l O2"}],"search_zh":"水、污水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"水、污水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a82dda1884ede9a1b2c339e","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr","parameters":[{"name":"Zakres","range":"(10 – 1000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (10 – 1000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Pracownia w Gorzowie Wielkopolskim","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (10 – 1000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, Scieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (10 – 1000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand - COD-Cr","parameters_en":[{"name":"Range","range":"(10 – 1000) mg/l O2"}],"search_en":"Water, Wastewater Chemical oxygen demand - COD-Cr Spectrophotometric method Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(10 – 1000) mg/l O2"}],"search_zh":"水、污水 化学需氧量（COD-Cr） 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、污水","methodology_zh":"化学需氧量（COD-Cr）"},{"_id":"6a82dda1884ede9a1b2c339f","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie chromu sześciowartościowego","parameters":[{"name":"Zakres","range":"(0,012 – 10) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chromu sześciowartościowego\nZakres (0,012 – 10) mg/l\nMetoda spektrofotometryczna","reference":"PN-77/C-04604.08","norm_bases":["PN-77/C-04604.08"],"lab_section":"Pracownia w Gorzowie Wielkopolskim","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie chromu sześciowartościowego\nZakres (0,012 – 10) mg/l\nMetoda spektrofotometryczna PN-77/C-04604.08 Scieki Stezenie chromu szesciowartosciowego\nZakres (0,012 – 10) mg/l\nMetoda spektrofotometryczna PN-77/C-04604.08","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hexavalent chromium concentration","parameters_en":[{"name":"Range","range":"(0,012 – 10) mg/l"}],"search_en":"Wastewater Hexavalent chromium concentration Spectrophotometric method Range PN-77/C-04604.08","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(0,012 – 10) mg/l"}],"search_zh":"污水 六价铬浓度 分光光度法 范围 PN-77/C-04604.08","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"六价铬浓度"},{"_id":"6a82dda1884ede9a1b2c33a0","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie anionów:","parameters":[{"name":"siarczany","range":"(2,0 – 1000) mg/l"},{"name":"chlorki","range":"(2,0 – 1000) mg/l"},{"name":"azot azotanowy","range":"(0,050 – 50) mg/l"},{"name":"azotany","range":"(0,20-220) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów:\nZakres:\nsiarczany (2,0 – 1000) mg/l\nchlorki (2,0 – 1000) mg/l\nazot azotanowy (0,050 – 50) mg/l\nazotany (0,20-220) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Pracownia w Gorzowie Wielkopolskim","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie anionów:\nZakres:\nsiarczany (2,0 – 1000) mg/l\nchlorki (2,0 – 1000) mg/l\nazot azotanowy (0,050 – 50) mg/l\nazotany (0,20-220) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Scieki Stezenie anionow:\nZakres:\nsiarczany (2,0 – 1000) mg/l\nchlorki (2,0 – 1000) mg/l\nazot azotanowy (0,050 – 50) mg/l\nazotany (0,20-220) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anion concentrations:","parameters_en":[{"name":"sulfates","range":"(2,0 – 1000) mg/l"},{"name":"chlorides","range":"(2,0 – 1000) mg/l"},{"name":"nitrate nitrogen","range":"(0,050 – 50) mg/l"},{"name":"nitrates","range":"(0,20-220) mg/l"}],"search_en":"Wastewater Anion concentrations: Ion chromatography with conductometric detection (IC-CD) sulfates chlorides nitrate nitrogen nitrates PN-EN ISO 10304-1:2009+AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Wastewater","methodology_zh":"阴离子浓度：","search_zh":"污水 阴离子浓度： 离子色谱-电导检测法（IC-CD） 硫酸盐 氯化物 硝酸盐氮 硝酸盐 PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"污水","parameters_zh":[{"name":"硫酸盐","range":"(2,0 – 1000) mg/l"},{"name":"氯化物","range":"(2,0 – 1000) mg/l"},{"name":"硝酸盐氮","range":"(0,050 – 50) mg/l"},{"name":"硝酸盐","range":"(0,20-220) mg/l"}]},{"_id":"6a82dda1884ede9a1b2c33a1","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Woda","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(5 – 100) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa\nZakres (5 – 100) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 metoda C","norm_bases":["PN-EN ISO 7887:2012 metoda C"],"lab_section":"Pracownia w Zielonej Górze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Barwa\nZakres (5 – 100) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 metoda C Woda Barwa\nZakres (5 – 100) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 metoda C","categories":["water"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(5 – 100) mg/l Pt"}],"search_en":"Water Colour Spectrophotometric method Range PN-EN ISO 7887:2012 metoda C","technique_en":"Spectrophotometric method","test_object_en":"Water","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5 – 100) mg/l Pt"}],"search_zh":"水 色度 分光光度法 范围 PN-EN ISO 7887:2012 metoda C","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a82dda1884ede9a1b2c33a2","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie ortofosforanów","parameters":[{"name":"Zakres","range":"(0,005 – 6,6) mg/l PPO4"},{"name":"Zakres","range":"(0,015 – 20,0) mg/l PO43-"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie ortofosforanów\nZakres:\nZakres (0,005 – 6,6) mg/l PPO4\nZakres (0,015 – 20,0) mg/l PO43-\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010"],"lab_section":"Pracownia w Zielonej Górze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie ortofosforanów\nZakres:\nZakres (0,005 – 6,6) mg/l PPO4\nZakres (0,015 – 20,0) mg/l PO43-\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010 Woda Stezenie ortofosforanow\nZakres:\nZakres (0,005 – 6,6) mg/l PPO4\nZakres (0,015 – 20,0) mg/l PO43-\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Orthophosphate concentration","parameters_en":[{"name":"Range","range":"(0,005 – 6,6) mg/l PPO4"},{"name":"Range","range":"(0,015 – 20,0) mg/l PO43-"}],"search_en":"Water Orthophosphate concentration Spectrophotometric method Range Range PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,005 – 6,6) mg/l PPO4"},{"name":"范围","range":"(0,015 – 20,0) mg/l PO43-"}],"search_zh":"水 正磷酸盐浓度 分光光度法 范围 范围 PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水","methodology_zh":"正磷酸盐浓度"},{"_id":"6a82dda1884ede9a1b2c33a3","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie metali","parameters":[{"name":"miedź","range":"(1,0 – 50) µg/l"},{"name":"selen","range":"(1,0 – 50) µg/l"},{"name":"arsen","range":"(1,0 – 50) µg/l"},{"name":"srebro","range":"(1,0 – 50) µg/l"},{"name":"nikiel","range":"(1,0 – 50) µg/l"},{"name":"ołów","range":"(0,5 – 10) µg/l"},{"name":"chrom","range":"(0,5 – 10) µg/l"},{"name":"antymon","range":"(0,5 – 10) µg/l"},{"name":"kadm","range":"(0,02 – 10) µg/l"},{"name":"molibden","range":"(1,0 – 10) µg/l"},{"name":"glin","range":"(20 – 250) µg/l"},{"name":"cynk","range":"(10 – 300) µg/l"}],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Stężenie metali\nZakres:\nmiedź (1,0 – 50) µg/l\nselen (1,0 – 50) µg/l\narsen (1,0 – 50) µg/l\nsrebro (1,0 – 50) µg/l\nnikiel (1,0 – 50) µg/l\nołów (0,5 – 10) µg/l\nchrom (0,5 – 10) µg/l\nantymon (0,5 – 10) µg/l\nkadm (0,02 – 10) µg/l\nmolibden (1,0 – 10) µg/l\nglin (20 – 250) µg/l\ncynk (10 – 300) µg/l\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PN-EN ISO 17294-2:2024-04","norm_bases":["PN-EN ISO 17294-2:2024-04"],"lab_section":"Pracownia w Zielonej Górze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie metali\nZakres:\nmiedź (1,0 – 50) µg/l\nselen (1,0 – 50) µg/l\narsen (1,0 – 50) µg/l\nsrebro (1,0 – 50) µg/l\nnikiel (1,0 – 50) µg/l\nołów (0,5 – 10) µg/l\nchrom (0,5 – 10) µg/l\nantymon (0,5 – 10) µg/l\nkadm (0,02 – 10) µg/l\nmolibden (1,0 – 10) µg/l\nglin (20 – 250) µg/l\ncynk (10 – 300) µg/l\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PN-EN ISO 17294-2:2024-04 Woda Stezenie metali\nZakres:\nmiedz (1,0 – 50) µg/l\nselen (1,0 – 50) µg/l\narsen (1,0 – 50) µg/l\nsrebro (1,0 – 50) µg/l\nnikiel (1,0 – 50) µg/l\nolow (0,5 – 10) µg/l\nchrom (0,5 – 10) µg/l\nantymon (0,5 – 10) µg/l\nkadm (0,02 – 10) µg/l\nmolibden (1,0 – 10) µg/l\nglin (20 – 250) µg/l\ncynk (10 – 300) µg/l\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PN-EN ISO 17294-2:2024-04","categories":["materials","water"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal concentrations","parameters_en":[{"name":"copper","range":"(1,0 – 50) µg/l"},{"name":"selenium","range":"(1,0 – 50) µg/l"},{"name":"arsenic","range":"(1,0 – 50) µg/l"},{"name":"silver","range":"(1,0 – 50) µg/l"},{"name":"nickel","range":"(1,0 – 50) µg/l"},{"name":"lead","range":"(0,5 – 10) µg/l"},{"name":"chromium","range":"(0,5 – 10) µg/l"},{"name":"antimony","range":"(0,5 – 10) µg/l"},{"name":"cadmium","range":"(0,02 – 10) µg/l"},{"name":"molybdenum","range":"(1,0 – 10) µg/l"},{"name":"aluminium","range":"(20 – 250) µg/l"},{"name":"zinc","range":"(10 – 300) µg/l"}],"search_en":"Water Metal concentrations Inductively coupled plasma mass spectrometry (ICP-MS) copper selenium arsenic silver nickel lead chromium antimony cadmium molybdenum aluminium zinc PN-EN ISO 17294-2:2024-04","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","test_object_en":"Water","methodology_zh":"金属浓度","parameters_zh":[{"name":"铜","range":"(1,0 – 50) µg/l"},{"name":"硒","range":"(1,0 – 50) µg/l"},{"name":"砷","range":"(1,0 – 50) µg/l"},{"name":"银","range":"(1,0 – 50) µg/l"},{"name":"镍","range":"(1,0 – 50) µg/l"},{"name":"铅","range":"(0,5 – 10) µg/l"},{"name":"铬","range":"(0,5 – 10) µg/l"},{"name":"锑","range":"(0,5 – 10) µg/l"},{"name":"镉","range":"(0,02 – 10) µg/l"},{"name":"钼","range":"(1,0 – 10) µg/l"},{"name":"铝","range":"(20 – 250) µg/l"},{"name":"锌","range":"(10 – 300) µg/l"}],"search_zh":"水 金属浓度 电感耦合等离子体质谱法（ICP-MS） 铜 硒 砷 银 镍 铅 铬 锑 镉 钼 铝 锌 PN-EN ISO 17294-2:2024-04","technique_zh":"电感耦合等离子体质谱法（ICP-MS）","test_object_zh":"水"},{"_id":"6a82dda1884ede9a1b2c33a4","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie anionów:","parameters":[{"name":"siarczany","range":"(0,5 – 500) mg/l"},{"name":"chlorki","range":"(0,5 – 1000) mg/l"},{"name":"azot azotanowy","range":"(0,05 – 56,5) mg/l"},{"name":"azotany","range":"(0,2 – 250) mg/l"},{"name":"fluorki","range":"(0,1 – 10,0) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów:\nZakres:\nsiarczany (0,5 – 500) mg/l\nchlorki (0,5 – 1000) mg/l\nazot azotanowy (0,05 – 56,5) mg/l\nazotany (0,2 – 250) mg/l\nfluorki (0,1 – 10,0) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Pracownia w Zielonej Górze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie anionów:\nZakres:\nsiarczany (0,5 – 500) mg/l\nchlorki (0,5 – 1000) mg/l\nazot azotanowy (0,05 – 56,5) mg/l\nazotany (0,2 – 250) mg/l\nfluorki (0,1 – 10,0) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda Stezenie anionow:\nZakres:\nsiarczany (0,5 – 500) mg/l\nchlorki (0,5 – 1000) mg/l\nazot azotanowy (0,05 – 56,5) mg/l\nazotany (0,2 – 250) mg/l\nfluorki (0,1 – 10,0) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anion concentrations:","parameters_en":[{"name":"sulfates","range":"(0,5 – 500) mg/l"},{"name":"chlorides","range":"(0,5 – 1000) mg/l"},{"name":"nitrate nitrogen","range":"(0,05 – 56,5) mg/l"},{"name":"nitrates","range":"(0,2 – 250) mg/l"},{"name":"fluorides","range":"(0,1 – 10,0) mg/l"}],"search_en":"Water Anion concentrations: Ion chromatography with conductometric detection (IC-CD) sulfates chlorides nitrate nitrogen nitrates fluorides PN-EN ISO 10304-1:2009+AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water","methodology_zh":"阴离子浓度：","search_zh":"水 阴离子浓度： 离子色谱-电导检测法（IC-CD） 硫酸盐 氯化物 硝酸盐氮 硝酸盐 氟化物 PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水","parameters_zh":[{"name":"硫酸盐","range":"(0,5 – 500) mg/l"},{"name":"氯化物","range":"(0,5 – 1000) mg/l"},{"name":"硝酸盐氮","range":"(0,05 – 56,5) mg/l"},{"name":"硝酸盐","range":"(0,2 – 250) mg/l"},{"name":"氟化物","range":"(0,1 – 10,0) mg/l"}]},{"_id":"6a82dda1884ede9a1b2c33a5","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie wielopierścieniowych węglowodorów aromatycznych:","parameters":[{"name":"fluoranten","range":"(0,001 – 50) µg/l"},{"name":"naftalen","range":"(0,001 – 50) µg/l"},{"name":"antracen","range":"(0,001 – 50) µg/l"},{"name":"benzo(b)fluoranten","range":"(0,0001 – 50) µg/l"},{"name":"benzo(k)fluoranten","range":"(0,0001 – 50) µg/l"},{"name":"benzo(g,h,i)perylen","range":"(0,0001 – 50) µg/l"},{"name":"indeno(1,2,3-c,d)piren","range":"(0,0001 – 50) µg/l"},{"name":"dibenzo(a,h)antracen","range":"(0,0001 – 50) µg/l"},{"name":"benzo(a)piren","range":"(0,00005 – 50) µg/l"},{"name":"Suma WWA (z obliczeń)"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluoroscencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluoroscencyjną (HPLC-FLD)"],"computed":[],"activity":"Stężenie wielopierścieniowych węglowodorów aromatycznych:\nZakres:\nfluoranten (0,001 – 50) µg/l\nnaftalen (0,001 – 50) µg/l\nantracen (0,001 – 50) µg/l\nbenzo(b)fluoranten (0,0001 – 50) µg/l\nbenzo(k)fluoranten (0,0001 – 50) µg/l\nbenzo(g,h,i)perylen (0,0001 – 50) µg/l\nindeno(1,2,3-c,d)piren (0,0001 – 50) µg/l\ndibenzo(a,h)antracen (0,0001 – 50) µg/l\nbenzo(a)piren (0,00005 – 50) µg/l\nSuma WWA (z obliczeń)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluoroscencyjną (HPLC-FLD)","reference":"PB-117/ZG wydanie 1 z dnia 20.01.2020 r.","norm_bases":["PB-117/ZG wydanie 1 z dnia 20.01.2020 r."],"lab_section":"Pracownia w Zielonej Górze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie wielopierścieniowych węglowodorów aromatycznych:\nZakres:\nfluoranten (0,001 – 50) µg/l\nnaftalen (0,001 – 50) µg/l\nantracen (0,001 – 50) µg/l\nbenzo(b)fluoranten (0,0001 – 50) µg/l\nbenzo(k)fluoranten (0,0001 – 50) µg/l\nbenzo(g,h,i)perylen (0,0001 – 50) µg/l\nindeno(1,2,3-c,d)piren (0,0001 – 50) µg/l\ndibenzo(a,h)antracen (0,0001 – 50) µg/l\nbenzo(a)piren (0,00005 – 50) µg/l\nSuma WWA (z obliczeń)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluoroscencyjną (HPLC-FLD) PB-117/ZG wydanie 1 z dnia 20.01.2020 r. Woda Stezenie wielopierscieniowych weglowodorow aromatycznych:\nZakres:\nfluoranten (0,001 – 50) µg/l\nnaftalen (0,001 – 50) µg/l\nantracen (0,001 – 50) µg/l\nbenzo(b)fluoranten (0,0001 – 50) µg/l\nbenzo(k)fluoranten (0,0001 – 50) µg/l\nbenzo(g,h,i)perylen (0,0001 – 50) µg/l\nindeno(1,2,3-c,d)piren (0,0001 – 50) µg/l\ndibenzo(a,h)antracen (0,0001 – 50) µg/l\nbenzo(a)piren (0,00005 – 50) µg/l\nSuma WWA (z obliczen)\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluoroscencyjna (HPLC-FLD) PB-117/ZG wydanie 1 z dnia 20.01.2020 r.","categories":["water"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of polycyclic aromatic hydrocarbons:","parameters_en":[{"name":"fluoranthene","range":"(0,001 – 50) µg/l"},{"name":"naphthalene","range":"(0,001 – 50) µg/l"},{"name":"anthracene","range":"(0,001 – 50) µg/l"},{"name":"benzo(b)fluoranthene","range":"(0,0001 – 50) µg/l"},{"name":"benzo(k)fluoranthene","range":"(0,0001 – 50) µg/l"},{"name":"benzo(g,h,i)perylene","range":"(0,0001 – 50) µg/l"},{"name":"indeno(1,2,3-c,d)pyrene","range":"(0,0001 – 50) µg/l"},{"name":"dibenzo(a,h)anthracene","range":"(0,0001 – 50) µg/l"},{"name":"benzo(a)pyrene","range":"(0,00005 – 50) µg/l"},{"name":"Sum of PAH (calculated)"}],"search_en":"Water Concentration of polycyclic aromatic hydrocarbons: High-performance liquid chromatography with fluorescence detection (HPLC-FLD) fluoranthene naphthalene anthracene benzo(b)fluoranthene benzo(k)fluoranthene benzo(g,h,i)perylene indeno(1,2,3-c,d)pyrene dibenzo(a,h)anthracene benzo(a)pyrene Sum of PAH (calculated) PB-117/ZG wydanie 1 z dnia 20.01.2020 r.","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","test_object_en":"Water","search_zh":"水 荧蒽 萘 蒽 苯并（b）荧蒽 苯并（k）荧蒽 苯并(g,h,i)苝 茚并(1,2,3-c,d)芘 二苯并（a,h）蒽 苯并（a）芘 多环芳烃总量（计算值） PB-117/ZG wydanie 1 z dnia 20.01.2020 r.","test_object_zh":"水","parameters_zh":[{"name":"荧蒽","range":"(0,001 – 50) µg/l"},{"name":"萘","range":"(0,001 – 50) µg/l"},{"name":"蒽","range":"(0,001 – 50) µg/l"},{"name":"苯并（b）荧蒽","range":"(0,0001 – 50) µg/l"},{"name":"苯并（k）荧蒽","range":"(0,0001 – 50) µg/l"},{"name":"苯并(g,h,i)苝","range":"(0,0001 – 50) µg/l"},{"name":"茚并(1,2,3-c,d)芘","range":"(0,0001 – 50) µg/l"},{"name":"二苯并（a,h）蒽","range":"(0,0001 – 50) µg/l"},{"name":"苯并（a）芘","range":"(0,00005 – 50) µg/l"},{"name":"多环芳烃总量（计算值）"}]},{"_id":"6a82dda1884ede9a1b2c33a6","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie metali:","parameters":[{"name":"bor","range":"(0,05 – 5,0) mg/l"}],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Stężenie metali:\nbor (0,05 – 5,0) mg/l\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PN-EN ISO 17294-2:2024-04","norm_bases":["PN-EN ISO 17294-2:2024-04"],"lab_section":"Pracownia w Zielonej Górze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie metali:\nbor (0,05 – 5,0) mg/l\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PN-EN ISO 17294-2:2024-04 Woda Stezenie metali:\nbor (0,05 – 5,0) mg/l\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PN-EN ISO 17294-2:2024-04","categories":["materials","water"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal concentrations:","parameters_en":[{"name":"boron","range":"(0,05 – 5,0) mg/l"}],"search_en":"Water Metal concentrations: Inductively coupled plasma mass spectrometry (ICP-MS) boron PN-EN ISO 17294-2:2024-04","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","test_object_en":"Water","search_zh":"水 金属浓度： 电感耦合等离子体质谱法（ICP-MS） 硼 PN-EN ISO 17294-2:2024-04","technique_zh":"电感耦合等离子体质谱法（ICP-MS）","test_object_zh":"水","parameters_zh":[{"name":"硼","range":"(0,05 – 5,0) mg/l"}],"methodology_zh":"金属浓度："},{"_id":"6a82dda1884ede9a1b2c33a7","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(0,5 – 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (0,5 – 100) mg/l\nMetoda spektrofotometryczna","reference":"PB-95/ZG wydanie 1 z dnia 20.01.2020 r.","norm_bases":["PB-95/ZG wydanie 1 z dnia 20.01.2020 r."],"lab_section":"Pracownia w Zielonej Górze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie azotu Kjeldahla\nZakres (0,5 – 100) mg/l\nMetoda spektrofotometryczna PB-95/ZG wydanie 1 z dnia 20.01.2020 r. Woda Stezenie azotu Kjeldahla\nZakres (0,5 – 100) mg/l\nMetoda spektrofotometryczna PB-95/ZG wydanie 1 z dnia 20.01.2020 r.","categories":["water"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,5 – 100) mg/l"}],"search_en":"Water Kjeldahl nitrogen concentration Spectrophotometric method Range PB-95/ZG wydanie 1 z dnia 20.01.2020 r.","technique_en":"Spectrophotometric method","test_object_en":"Water","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(0,5 – 100) mg/l"}],"search_zh":"水 凯氏氮浓度 分光光度法 范围 PB-95/ZG wydanie 1 z dnia 20.01.2020 r.","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a82dda1884ede9a1b2c33a8","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Woda","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","parameters":[{"name":"Zakres","range":"(0,5 – 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":"Pracownia w Zielonej Górze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand - BOD5","parameters_en":[{"name":"Range","range":"(0,5 – 6,0) mg/l O2"}],"search_en":"Water Biochemical oxygen demand - BOD5 Electrochemical method Range PN-EN 1899-2:2002","technique_en":"Electrochemical method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,5 – 6,0) mg/l O2"}],"search_zh":"水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a82dda1884ede9a1b2c33a9","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","parameters":[{"name":"Zakres","range":"(3,0 – 6000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (3,0 – 6000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Pracownia w Zielonej Górze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (3,0 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda, Scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (3,0 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand - BOD5","parameters_en":[{"name":"Range","range":"(3,0 – 6000) mg/l O2"}],"search_en":"Water, Wastewater Biochemical oxygen demand - BOD5 Electrochemical method Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(3,0 – 6000) mg/l O2"}],"search_zh":"水、污水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"水、污水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a82dda1884ede9a1b2c33aa","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,002 – 2,5) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,002 – 2,5) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Pracownia w Zielonej Górze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu azotynowego\nZakres (0,002 – 2,5) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, Scieki Stezenie azotu azotynowego\nZakres (0,002 – 2,5) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,002 – 2,5) mg/l"}],"search_en":"Water, Wastewater Nitrite nitrogen concentration Spectrophotometric method Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,002 – 2,5) mg/l"}],"search_zh":"水、污水 亚硝态氮浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a82dda1884ede9a1b2c33ab","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,01 – 8,2) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotynów\nZakres (0,01 – 8,2) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Pracownia w Zielonej Górze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotynów\nZakres (0,01 – 8,2) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, Scieki Stezenie azotynow\nZakres (0,01 – 8,2) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite concentration","parameters_en":[{"name":"Range","range":"(0,01 – 8,2) mg/l"}],"search_en":"Water, Wastewater Nitrite concentration Spectrophotometric method Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,01 – 8,2) mg/l"}],"search_zh":"水、污水 亚硝酸盐浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a82dda1884ede9a1b2c33ac","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,006 – 14,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,006 – 14,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 +Ap 1:2010 +Ap2: 2010","norm_bases":["PN-EN ISO 6878:2006 +Ap 1:2010 +Ap2: 2010"],"lab_section":"Pracownia w Zielonej Górze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie fosforu ogólnego\nZakres (0,006 – 14,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 +Ap 1:2010 +Ap2: 2010 Woda, Scieki Stezenie fosforu ogolnego\nZakres (0,006 – 14,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 +Ap 1:2010 +Ap2: 2010","categories":["water"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,006 – 14,0) mg/l"}],"search_en":"Water, Wastewater Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006 +Ap 1:2010 +Ap2: 2010","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,006 – 14,0) mg/l"}],"search_zh":"水、污水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006 +Ap 1:2010 +Ap2: 2010","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a82dda1884ede9a1b2c33ad","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr","parameters":[{"name":"Zakres","range":"(10 – 10000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (10 – 10000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Pracownia w Zielonej Górze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (10 – 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, Scieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (10 – 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand - COD-Cr","parameters_en":[{"name":"Range","range":"(10 – 10000) mg/l O2"}],"search_en":"Water, Wastewater Chemical oxygen demand - COD-Cr Spectrophotometric method Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(10 – 10000) mg/l O2"}],"search_zh":"水、污水 化学需氧量（COD-Cr） 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、污水","methodology_zh":"化学需氧量（COD-Cr）"},{"_id":"6a82dda1884ede9a1b2c33ae","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu ogólnego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PB-26/CLB wydanie 1 z dnia 16.01.2026","norm_bases":["PB-26/CLB wydanie 1 z dnia 16.01.2026"],"lab_section":"Pracownia w Zielonej Górze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu ogólnego (z obliczeń) PB-26/CLB wydanie 1 z dnia 16.01.2026 Woda, Scieki Stezenie azotu ogolnego (z obliczen) PB-26/CLB wydanie 1 z dnia 16.01.2026","categories":["water"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration (calculated)","search_en":"Water, Wastewater Total nitrogen concentration (calculated) PB-26/CLB wydanie 1 z dnia 16.01.2026","test_object_en":"Water, Wastewater","methodology_zh":"总氮浓度（计算值）","search_zh":"水、污水 总氮浓度（计算值） PB-26/CLB wydanie 1 z dnia 16.01.2026","test_object_zh":"水、污水"},{"_id":"6a82dda1884ede9a1b2c33af","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Pracownia w Zielonej Górze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Zawiesiny ogólne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, Scieki Zawiesiny ogolne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 1000) mg/l"}],"search_en":"Water, Wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, Wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 1000) mg/l"}],"search_zh":"水、污水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、污水"},{"_id":"6a82dda1884ede9a1b2c33b0","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie rtęci","parameters":[{"name":"Zakres","range":"(20 – 500) ng/l"}],"technique":"Metoda atomowej spektrometrii fluorescencyjnej (ASF)","techniques":["Metoda atomowej spektrometrii fluorescencyjnej (ASF)"],"computed":[],"activity":"Stężenie rtęci\nZakres (20 – 500) ng/l\nMetoda atomowej spektrometrii fluorescencyjnej (ASF)","reference":"PN-EN ISO 17852:2009","norm_bases":["PN-EN ISO 17852:2009"],"lab_section":"Pracownia w Zielonej Górze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie rtęci\nZakres (20 – 500) ng/l\nMetoda atomowej spektrometrii fluorescencyjnej (ASF) PN-EN ISO 17852:2009 Woda, Scieki Stezenie rteci\nZakres (20 – 500) ng/l\nMetoda atomowej spektrometrii fluorescencyjnej (ASF) PN-EN ISO 17852:2009","categories":["water"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury concentration","parameters_en":[{"name":"Range","range":"(20 – 500) ng/l"}],"search_en":"Water, Wastewater Mercury concentration Range PN-EN ISO 17852:2009","test_object_en":"Water, Wastewater","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(20 – 500) ng/l"}],"search_zh":"水、污水 汞浓度 范围 PN-EN ISO 17852:2009","test_object_zh":"水、污水"},{"_id":"6a82dda1884ede9a1b2c33b1","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie metali","parameters":[{"name":"arsen","range":"(0,010 – 10) mg/l"},{"name":"kadm","range":"(0,010 – 10) mg/l"},{"name":"miedź","range":"(0,020 – 10) mg/l"},{"name":"chrom","range":"(0,010 – 10) mg/l"},{"name":"nikiel","range":"(0,010 – 10) mg/l"},{"name":"ołów","range":"(0,010 – 10) mg/l"},{"name":"żelazo","range":"(0,010 – 10) mg/l"},{"name":"mangan","range":"(0,010-10) mg/l"},{"name":"cynk","range":"(0,050-10) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie metali\nZakres:\narsen (0,010 – 10) mg/l\nkadm (0,010 – 10) mg/l\nmiedź (0,020 – 10) mg/l\nchrom (0,010 – 10) mg/l\nnikiel (0,010 – 10) mg/l\nołów (0,010 – 10) mg/l\nżelazo (0,010 – 10) mg/l\nmangan (0,010-10) mg/l\ncynk (0,050-10) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":"Pracownia w Zielonej Górze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie metali\nZakres:\narsen (0,010 – 10) mg/l\nkadm (0,010 – 10) mg/l\nmiedź (0,020 – 10) mg/l\nchrom (0,010 – 10) mg/l\nnikiel (0,010 – 10) mg/l\nołów (0,010 – 10) mg/l\nżelazo (0,010 – 10) mg/l\nmangan (0,010-10) mg/l\ncynk (0,050-10) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Woda, Scieki Stezenie metali\nZakres:\narsen (0,010 – 10) mg/l\nkadm (0,010 – 10) mg/l\nmiedz (0,020 – 10) mg/l\nchrom (0,010 – 10) mg/l\nnikiel (0,010 – 10) mg/l\nolow (0,010 – 10) mg/l\nzelazo (0,010 – 10) mg/l\nmangan (0,010-10) mg/l\ncynk (0,050-10) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["materials","water"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal concentrations","parameters_en":[{"name":"arsenic","range":"(0,010 – 10) mg/l"},{"name":"cadmium","range":"(0,010 – 10) mg/l"},{"name":"copper","range":"(0,020 – 10) mg/l"},{"name":"chromium","range":"(0,010 – 10) mg/l"},{"name":"nickel","range":"(0,010 – 10) mg/l"},{"name":"lead","range":"(0,010 – 10) mg/l"},{"name":"iron","range":"(0,010 – 10) mg/l"},{"name":"manganese","range":"(0,010-10) mg/l"},{"name":"zinc","range":"(0,050-10) mg/l"}],"search_en":"Water, Wastewater Metal concentrations Inductively coupled plasma optical emission spectrometry (ICP-OES) arsenic cadmium copper chromium nickel lead iron manganese zinc PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Water, Wastewater","methodology_zh":"金属浓度","parameters_zh":[{"name":"砷","range":"(0,010 – 10) mg/l"},{"name":"镉","range":"(0,010 – 10) mg/l"},{"name":"铜","range":"(0,020 – 10) mg/l"},{"name":"铬","range":"(0,010 – 10) mg/l"},{"name":"镍","range":"(0,010 – 10) mg/l"},{"name":"铅","range":"(0,010 – 10) mg/l"},{"name":"铁","range":"(0,010 – 10) mg/l"},{"name":"锰","range":"(0,010-10) mg/l"},{"name":"锌","range":"(0,050-10) mg/l"}],"search_zh":"水、污水 金属浓度 电感耦合等离子体原子发射光谱法（ICP-OES） 砷 镉 铜 铬 镍 铅 铁 锰 锌 PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"水、污水"},{"_id":"6a82dda1884ede9a1b2c33b2","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,050-20) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,050-20) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":"Pracownia w Zielonej Górze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie fosforu ogólnego\nZakres (0,050-20) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Woda, Scieki Stezenie fosforu ogolnego\nZakres (0,050-20) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,050-20) mg/l"}],"search_en":"Water, Wastewater Total phosphorus concentration Inductively coupled plasma optical emission spectrometry (ICP-OES) Range PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Water, Wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,050-20) mg/l"}],"search_zh":"水、污水 总磷浓度 电感耦合等离子体原子发射光谱法（ICP-OES） 范围 PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"水、污水"},{"_id":"6a82dda1884ede9a1b2c33b3","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie jonu amonowego","parameters":[{"name":"Zakres","range":"(0,050 – 25,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonu amonowego\nZakres (0,050 – 25,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Pracownia w Zielonej Górze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie jonu amonowego\nZakres (0,050 – 25,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, Scieki Stezenie jonu amonowego\nZakres (0,050 – 25,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium ion concentration","parameters_en":[{"name":"Range","range":"(0,050 – 25,0) mg/l"}],"search_en":"Water, Wastewater Ammonium ion concentration Spectrophotometric method Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,050 – 25,0) mg/l"}],"search_zh":"水、污水 铵离子浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a82dda1884ede9a1b2c33b4","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,040 – 20,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,040 – 20,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Pracownia w Zielonej Górze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu amonowego\nZakres (0,040 – 20,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, Scieki Stezenie azotu amonowego\nZakres (0,040 – 20,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,040 – 20,0) mg/l"}],"search_en":"Water, Wastewater Ammonium nitrogen concentration Spectrophotometric method Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,040 – 20,0) mg/l"}],"search_zh":"水、污水 氨氮浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a82dda1884ede9a1b2c33b5","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie aldehydu mrówkowego","parameters":[{"name":"Zakres","range":"(0,015 – 1,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie aldehydu mrówkowego\nZakres (0,015 – 1,00) mg/l\nMetoda spektrofotometryczna","reference":"PB-114/ZG wydanie 1 z dnia 04.01.2021 | na podstawie testu kuwetowego Hach Lange nr LCS 325","norm_bases":["PB-114/ZG wydanie 1 z dnia 04.01.2021","na podstawie testu kuwetowego Hach Lange nr LCS 325"],"lab_section":"Pracownia w Zielonej Górze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie aldehydu mrówkowego\nZakres (0,015 – 1,00) mg/l\nMetoda spektrofotometryczna PB-114/ZG wydanie 1 z dnia 04.01.2021 | na podstawie testu kuwetowego Hach Lange nr LCS 325 Woda, Scieki Stezenie aldehydu mrowkowego\nZakres (0,015 – 1,00) mg/l\nMetoda spektrofotometryczna PB-114/ZG wydanie 1 z dnia 04.01.2021 | na podstawie testu kuwetowego Hach Lange nr LCS 325","categories":["water"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Formaldehyde concentration","parameters_en":[{"name":"Range","range":"(0,015 – 1,00) mg/l"}],"search_en":"Water, Wastewater Formaldehyde concentration Spectrophotometric method Range PB-114/ZG wydanie 1 z dnia 04.01.2021 | na podstawie testu kuwetowego Hach Lange nr LCS 325","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(0,015 – 1,00) mg/l"}],"search_zh":"水、污水 甲醛浓度 分光光度法 范围 PB-114/ZG wydanie 1 z dnia 04.01.2021 | na podstawie testu kuwetowego Hach Lange nr LCS 325","technique_zh":"分光光度法","test_object_zh":"水、污水","methodology_zh":"甲醛浓度"},{"_id":"6a82dda1884ede9a1b2c33b6","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(1,0 – 500) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (1,0 – 500) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Pracownia w Zielonej Górze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu Kjeldahla\nZakres (1,0 – 500) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Woda, Scieki Stezenie azotu Kjeldahla\nZakres (1,0 – 500) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(1,0 – 500) mg/l"}],"search_en":"Water, Wastewater Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Water, Wastewater","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(1,0 – 500) mg/l"}],"search_zh":"水、污水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"水、污水"},{"_id":"6a82dda1884ede9a1b2c33b7","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Indeks oleju mineralnego","parameters":[{"name":"Zakres","range":"(0,05 – 100) mg/l"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Indeks oleju mineralnego\nZakres (0,05 – 100) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 9377-2:2003","norm_bases":["PN-EN ISO 9377-2:2003"],"lab_section":"Pracownia w Zielonej Górze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Indeks oleju mineralnego\nZakres (0,05 – 100) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 9377-2:2003 Woda, Scieki Indeks oleju mineralnego\nZakres (0,05 – 100) mg/l\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 9377-2:2003","categories":["water","petro"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mineral oil index","parameters_en":[{"name":"Range","range":"(0,05 – 100) mg/l"}],"search_en":"Water, Wastewater Mineral oil index Gas chromatography with flame ionization detection (GC-FID) Range PN-EN ISO 9377-2:2003","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(0,05 – 100) mg/l"}],"search_zh":"水、污水 矿物油指数 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN ISO 9377-2:2003","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"水、污水","methodology_zh":"矿物油指数"},{"_id":"6a82dda1884ede9a1b2c33b8","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Gleba","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 11,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 11,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":"Pracownia w Zielonej Górze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba pH\nZakres 2,0 – 11,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Gleba pH\nZakres 2,0 – 11,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["environment"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 11,0"}],"search_en":"Soil pH Potentiometric method Range PN-EN ISO 10390:2022-09","technique_en":"Potentiometric method","test_object_en":"Soil","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 11,0"}],"search_zh":"土壤 pH 值 电位法 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法","test_object_zh":"土壤"},{"_id":"6a82dda1884ede9a1b2c33b9","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Gleba","methodology":"Sucha masa/zawartość wody","parameters":[{"name":"Zakres","range":"(1,0 – 99) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha masa/zawartość wody\nZakres (1,0 – 99) %\nMetoda wagowa","reference":"PN-EN ISO 11465:2026-03 Metoda A","norm_bases":["PN-EN ISO 11465:2026-03 Metoda A"],"lab_section":"Pracownia w Zielonej Górze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Sucha masa/zawartość wody\nZakres (1,0 – 99) %\nMetoda wagowa PN-EN ISO 11465:2026-03 Metoda A Gleba Sucha masa/zawartosc wody\nZakres (1,0 – 99) %\nMetoda wagowa PN-EN ISO 11465:2026-03 Metoda A","categories":["water","environment"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry matter/water content","parameters_en":[{"name":"Range","range":"(1,0 – 99) %"}],"search_en":"Soil Dry matter/water content Gravimetric method Range PN-EN ISO 11465:2026-03 Metoda A","technique_en":"Gravimetric method","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(1,0 – 99) %"}],"search_zh":"土壤 重量法 范围 PN-EN ISO 11465:2026-03 Metoda A","technique_zh":"重量法","test_object_zh":"土壤"},{"_id":"6a82dda1884ede9a1b2c33ba","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość metali:","parameters":[{"name":"kadm","range":"(1,0-20) mg/kg"},{"name":"miedź","range":"(20 – 1000) mg/kg"},{"name":"chrom","range":"(50 – 2000) mg/kg"},{"name":"nikiel","range":"(20 – 1000) mg/kg"},{"name":"ołów","range":"(40 – 1000) mg/kg"},{"name":"cynk","range":"(50 – 2500) mg/kg"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość metali:\nZakres:\nkadm (1,0-20) mg/kg\nmiedź (20 – 1000) mg/kg\nchrom (50 – 2000) mg/kg\nnikiel (20 – 1000) mg/kg\nołów (40 – 1000) mg/kg\ncynk (50 – 2500) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009 | PN-EN ISO 54321:2021-07","norm_bases":["PN-EN ISO 11885:2009","PN-EN ISO 54321:2021-07"],"lab_section":"Pracownia w Zielonej Górze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość metali:\nZakres:\nkadm (1,0-20) mg/kg\nmiedź (20 – 1000) mg/kg\nchrom (50 – 2000) mg/kg\nnikiel (20 – 1000) mg/kg\nołów (40 – 1000) mg/kg\ncynk (50 – 2500) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 | PN-EN ISO 54321:2021-07 Gleba Zawartosc metali:\nZakres:\nkadm (1,0-20) mg/kg\nmiedz (20 – 1000) mg/kg\nchrom (50 – 2000) mg/kg\nnikiel (20 – 1000) mg/kg\nolow (40 – 1000) mg/kg\ncynk (50 – 2500) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009 | PN-EN ISO 54321:2021-07","categories":["materials","environment"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal content:","parameters_en":[{"name":"cadmium","range":"(1,0-20) mg/kg"},{"name":"copper","range":"(20 – 1000) mg/kg"},{"name":"chromium","range":"(50 – 2000) mg/kg"},{"name":"nickel","range":"(20 – 1000) mg/kg"},{"name":"lead","range":"(40 – 1000) mg/kg"},{"name":"zinc","range":"(50 – 2500) mg/kg"}],"search_en":"Soil Metal content: Inductively coupled plasma optical emission spectrometry (ICP-OES) cadmium copper chromium nickel lead zinc PN-EN ISO 11885:2009 | PN-EN ISO 54321:2021-07","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Soil","parameters_zh":[{"name":"镉","range":"(1,0-20) mg/kg"},{"name":"铜","range":"(20 – 1000) mg/kg"},{"name":"铬","range":"(50 – 2000) mg/kg"},{"name":"镍","range":"(20 – 1000) mg/kg"},{"name":"铅","range":"(40 – 1000) mg/kg"},{"name":"锌","range":"(50 – 2500) mg/kg"}],"search_zh":"土壤 金属含量： 电感耦合等离子体原子发射光谱法（ICP-OES） 镉 铜 铬 镍 铅 锌 PN-EN ISO 11885:2009 | PN-EN ISO 54321:2021-07","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"土壤","methodology_zh":"金属含量："},{"_id":"6a82dda1884ede9a1b2c33bb","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość węglowodorów ropopochodnych od C12 do C35","parameters":[{"name":"Zakres","range":"(30,0 – 10000) mg/kg"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość węglowodorów ropopochodnych od C12 do C35\nZakres (30,0 – 10000) mg/kg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 16703:2011","norm_bases":["PN-EN ISO 16703:2011"],"lab_section":"Pracownia w Zielonej Górze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość węglowodorów ropopochodnych od C12 do C35\nZakres (30,0 – 10000) mg/kg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 16703:2011 Gleba Zawartosc weglowodorow ropopochodnych od C12 do C35\nZakres (30,0 – 10000) mg/kg\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 16703:2011","categories":["environment"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(30,0 – 10000) mg/kg"}],"search_en":"Soil Gas chromatography with flame ionization detection (GC-FID) Range PN-EN ISO 16703:2011","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(30,0 – 10000) mg/kg"}],"search_zh":"土壤 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN ISO 16703:2011","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"土壤"},{"_id":"6a82dda1884ede9a1b2c33bc","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Gleba","methodology":"Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)","parameters":[{"name":"Antracen"},{"name":"Fluoranten"},{"name":"Benzo(a)antracen"},{"name":"Benzo(b)fluoranten"},{"name":"Benzo(k)fluoranten"},{"name":"Benzo(a)piren"},{"name":"Dibenzo(a,h)antracen"},{"name":"Indeno(123-cd)piren"},{"name":"Chryzen"},{"name":"Fenantren"},{"name":"Benzo(g,h,i)perylen"},{"name":"Zakres","range":"(0,020 – 10) mg/kg"},{"name":"Naftalen"},{"name":"Zakres","range":"(0,20 – 10) mg/kg"},{"name":"Suma WWA (z obliczeń)"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluoroscencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluoroscencyjną (HPLC-FLD)"],"computed":[],"activity":"Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nAntracen\nFluoranten\nBenzo(a)antracen\nBenzo(b)fluoranten\nBenzo(k)fluoranten\nBenzo(a)piren\nDibenzo(a,h)antracen\nIndeno(123-cd)piren\nChryzen\nFenantren\nBenzo(g,h,i)perylen\nZakres (0,020 – 10) mg/kg\nNaftalen\nZakres (0,20 – 10) mg/kg\nSuma WWA (z obliczeń)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluoroscencyjną (HPLC-FLD)","reference":"PN-ISO 13877:2004","norm_bases":["PN-ISO 13877:2004"],"lab_section":"Pracownia w Zielonej Górze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nAntracen\nFluoranten\nBenzo(a)antracen\nBenzo(b)fluoranten\nBenzo(k)fluoranten\nBenzo(a)piren\nDibenzo(a,h)antracen\nIndeno(123-cd)piren\nChryzen\nFenantren\nBenzo(g,h,i)perylen\nZakres (0,020 – 10) mg/kg\nNaftalen\nZakres (0,20 – 10) mg/kg\nSuma WWA (z obliczeń)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluoroscencyjną (HPLC-FLD) PN-ISO 13877:2004 Gleba Zawartosc wielopierscieniowych weglowodorow aromatycznych (WWA)\nZakres:\nAntracen\nFluoranten\nBenzo(a)antracen\nBenzo(b)fluoranten\nBenzo(k)fluoranten\nBenzo(a)piren\nDibenzo(a,h)antracen\nIndeno(123-cd)piren\nChryzen\nFenantren\nBenzo(g,h,i)perylen\nZakres (0,020 – 10) mg/kg\nNaftalen\nZakres (0,20 – 10) mg/kg\nSuma WWA (z obliczen)\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluoroscencyjna (HPLC-FLD) PN-ISO 13877:2004","categories":["environment"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Polycyclic aromatic hydrocarbons (PAH) content","parameters_en":[{"name":"Anthracene"},{"name":"Fluoranthene"},{"name":"Benzo(a)anthracene"},{"name":"Benzo(b)fluoranthene"},{"name":"Benzo(k)fluoranthene"},{"name":"Benzo(a)pyrene"},{"name":"Dibenzo(a,h)anthracene"},{"name":"Indeno(123-cd)piren"},{"name":"Chrysene"},{"name":"Phenanthrene"},{"name":"Benzo(g,h,i)perylene"},{"name":"Range","range":"(0,020 – 10) mg/kg"},{"name":"Naphthalene"},{"name":"Range","range":"(0,20 – 10) mg/kg"},{"name":"Sum of PAH (calculated)"}],"search_en":"Soil Polycyclic aromatic hydrocarbons (PAH) content High-performance liquid chromatography with fluorescence detection (HPLC-FLD) Anthracene Fluoranthene Benzo(a)anthracene Benzo(b)fluoranthene Benzo(k)fluoranthene Benzo(a)pyrene Dibenzo(a,h)anthracene Chrysene Phenanthrene Benzo(g,h,i)perylene Range Naphthalene Range Sum of PAH (calculated) PN-ISO 13877:2004","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","test_object_en":"Soil","parameters_zh":[{"name":"蒽"},{"name":"荧蒽"},{"name":"苯并(a)蒽"},{"name":"苯并(b)荧蒽"},{"name":"苯并(k)荧蒽"},{"name":"苯并(a)芘"},{"name":"二苯并(a,h)蒽"},{"name":"Indeno(123-cd)piren"},{"name":"䓛"},{"name":"菲"},{"name":"苯并(g,h,i)苝"},{"name":"范围","range":"(0,020 – 10) mg/kg"},{"name":"萘"},{"name":"范围","range":"(0,20 – 10) mg/kg"},{"name":"多环芳烃总量（计算值）"}],"search_zh":"土壤 多环芳烃（PAHs）含量 蒽 荧蒽 苯并(a)蒽 苯并(b)荧蒽 苯并(k)荧蒽 苯并(a)芘 二苯并(a,h)蒽 䓛 菲 苯并(g,h,i)苝 范围 萘 范围 多环芳烃总量（计算值） PN-ISO 13877:2004","test_object_zh":"土壤","methodology_zh":"多环芳烃（PAHs）含量"},{"_id":"6a82dda1884ede9a1b2c33bd","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie anionów","parameters":[{"name":"chlorki","range":"(1,0 – 1000) mg/l"},{"name":"siarczany","range":"(1,0 – 1000) mg/l"},{"name":"azotany","range":"(1,0 – 500) mg/l"},{"name":"azot azotanowy","range":"(0,2 – 115) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów\nZakres:\nchlorki (1,0 – 1000) mg/l\nsiarczany (1,0 – 1000) mg/l\nazotany (1,0 – 500) mg/l\nazot azotanowy (0,2 – 115) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Pracownia w Zielonej Górze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie anionów\nZakres:\nchlorki (1,0 – 1000) mg/l\nsiarczany (1,0 – 1000) mg/l\nazotany (1,0 – 500) mg/l\nazot azotanowy (0,2 – 115) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Scieki Stezenie anionow\nZakres:\nchlorki (1,0 – 1000) mg/l\nsiarczany (1,0 – 1000) mg/l\nazotany (1,0 – 500) mg/l\nazot azotanowy (0,2 – 115) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anion concentrations","parameters_en":[{"name":"chlorides","range":"(1,0 – 1000) mg/l"},{"name":"sulfates","range":"(1,0 – 1000) mg/l"},{"name":"nitrates","range":"(1,0 – 500) mg/l"},{"name":"nitrate nitrogen","range":"(0,2 – 115) mg/l"}],"search_en":"Wastewater Anion concentrations Ion chromatography with conductometric detection (IC-CD) chlorides sulfates nitrates nitrate nitrogen PN-EN ISO 10304-1:2009+AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Wastewater","methodology_zh":"阴离子浓度","search_zh":"污水 阴离子浓度 离子色谱-电导检测法（IC-CD） 氯化物 硫酸盐 硝酸盐 硝酸盐氮 PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"污水","parameters_zh":[{"name":"氯化物","range":"(1,0 – 1000) mg/l"},{"name":"硫酸盐","range":"(1,0 – 1000) mg/l"},{"name":"硝酸盐","range":"(1,0 – 500) mg/l"},{"name":"硝酸盐氮","range":"(0,2 – 115) mg/l"}]},{"_id":"6a82dda1884ede9a1b2c33be","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość metali","parameters":[{"name":"miedź","range":"(50 – 2500) mg/kg"},{"name":"kadm","range":"(10 – 100) mg/kg"},{"name":"chrom","range":"(100 – 3000) mg/kg"},{"name":"nikiel","range":"(50 – 2000) mg/kg"},{"name":"ołów","range":"(100 – 2000) mg/kg"},{"name":"cynk","range":"(100 – 5000) mg/kg"},{"name":"wapń","range":"(0,05-20) %"},{"name":"magnez","range":"(0,01-10) %"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość metali\nZakres:\nmiedź (50 – 2500) mg/kg\nkadm (10 – 100) mg/kg\nchrom (100 – 3000) mg/kg\nnikiel (50 – 2000) mg/kg\nołów (100 – 2000) mg/kg\ncynk (100 – 5000) mg/kg\nwapń (0,05-20) %\nmagnez (0,01-10) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 54321:2021-07 | PN-EN ISO 22036:2024-07","norm_bases":["PN-EN ISO 54321:2021-07","PN-EN ISO 22036:2024-07"],"lab_section":"Pracownia w Zielonej Górze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość metali\nZakres:\nmiedź (50 – 2500) mg/kg\nkadm (10 – 100) mg/kg\nchrom (100 – 3000) mg/kg\nnikiel (50 – 2000) mg/kg\nołów (100 – 2000) mg/kg\ncynk (100 – 5000) mg/kg\nwapń (0,05-20) %\nmagnez (0,01-10) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 54321:2021-07 | PN-EN ISO 22036:2024-07 Osady sciekowe Zawartosc metali\nZakres:\nmiedz (50 – 2500) mg/kg\nkadm (10 – 100) mg/kg\nchrom (100 – 3000) mg/kg\nnikiel (50 – 2000) mg/kg\nolow (100 – 2000) mg/kg\ncynk (100 – 5000) mg/kg\nwapn (0,05-20) %\nmagnez (0,01-10) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 54321:2021-07 | PN-EN ISO 22036:2024-07","categories":["materials","water"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal content","parameters_en":[{"name":"copper","range":"(50 – 2500) mg/kg"},{"name":"cadmium","range":"(10 – 100) mg/kg"},{"name":"chromium","range":"(100 – 3000) mg/kg"},{"name":"nickel","range":"(50 – 2000) mg/kg"},{"name":"lead","range":"(100 – 2000) mg/kg"},{"name":"zinc","range":"(100 – 5000) mg/kg"},{"name":"calcium","range":"(0,05-20) %"},{"name":"magnesium","range":"(0,01-10) %"}],"search_en":"Sewage sludge Metal content Inductively coupled plasma optical emission spectrometry (ICP-OES) copper cadmium chromium nickel lead zinc calcium magnesium PN-EN ISO 54321:2021-07 | PN-EN ISO 22036:2024-07","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Sewage sludge","parameters_zh":[{"name":"铜","range":"(50 – 2500) mg/kg"},{"name":"镉","range":"(10 – 100) mg/kg"},{"name":"铬","range":"(100 – 3000) mg/kg"},{"name":"镍","range":"(50 – 2000) mg/kg"},{"name":"铅","range":"(100 – 2000) mg/kg"},{"name":"锌","range":"(100 – 5000) mg/kg"},{"name":"钙","range":"(0,05-20) %"},{"name":"镁","range":"(0,01-10) %"}],"search_zh":"污泥 金属含量 电感耦合等离子体原子发射光谱法（ICP-OES） 铜 镉 铬 镍 铅 锌 钙 镁 PN-EN ISO 54321:2021-07 | PN-EN ISO 22036:2024-07","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"污泥","methodology_zh":"金属含量"},{"_id":"6a82dda1884ede9a1b2c33bf","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 11,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 11,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":"Pracownia w Zielonej Górze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe pH\nZakres 2,0 – 11,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Osady sciekowe pH\nZakres 2,0 – 11,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["water"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 11,0"}],"search_en":"Sewage sludge pH Potentiometric method Range PN-EN ISO 10390:2022-09","technique_en":"Potentiometric method","test_object_en":"Sewage sludge","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 11,0"}],"search_zh":"污泥 pH 值 电位法 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法","test_object_zh":"污泥"},{"_id":"6a82dda1884ede9a1b2c33c0","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Sucha pozostałość / zawartość wody","parameters":[{"name":"Zakres","range":"(1,0 – 99) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha pozostałość / zawartość wody\nZakres (1,0 – 99) %\nMetoda wagowa","reference":"PN-EN ISO 11465:2026-03 Metoda A","norm_bases":["PN-EN ISO 11465:2026-03 Metoda A"],"lab_section":"Pracownia w Zielonej Górze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Sucha pozostałość / zawartość wody\nZakres (1,0 – 99) %\nMetoda wagowa PN-EN ISO 11465:2026-03 Metoda A Osady sciekowe Sucha pozostalosc / zawartosc wody\nZakres (1,0 – 99) %\nMetoda wagowa PN-EN ISO 11465:2026-03 Metoda A","categories":["water"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry residue / water content","parameters_en":[{"name":"Range","range":"(1,0 – 99) %"}],"search_en":"Sewage sludge Dry residue / water content Gravimetric method Range PN-EN ISO 11465:2026-03 Metoda A","technique_en":"Gravimetric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(1,0 – 99) %"}],"search_zh":"污泥 干残渣/水分含量 重量法 范围 PN-EN ISO 11465:2026-03 Metoda A","technique_zh":"重量法","test_object_zh":"污泥","methodology_zh":"干残渣/水分含量"},{"_id":"6a82dda1884ede9a1b2c33c1","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Straty przy prażeniu suchej masy (LOI)","parameters":[{"name":"Zakres","range":"(10,0 – 90,0)%"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Straty przy prażeniu suchej masy (LOI)\nZakres (10,0 – 90,0)%\nMetoda wagowa","reference":"PN-EN ISO 15935:2022-01 z wyłączeniem pkt 7.4 i 8.2","norm_bases":["PN-EN ISO 15935:2022-01 z wyłączeniem pkt 7.4 i 8.2"],"lab_section":"Pracownia w Zielonej Górze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Straty przy prażeniu suchej masy (LOI)\nZakres (10,0 – 90,0)%\nMetoda wagowa PN-EN ISO 15935:2022-01 z wyłączeniem pkt 7.4 i 8.2 Osady sciekowe Straty przy prazeniu suchej masy (LOI)\nZakres (10,0 – 90,0)%\nMetoda wagowa PN-EN ISO 15935:2022-01 z wylaczeniem pkt 7.4 i 8.2","categories":["water"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Loss on ignition of dry matter (LOI)","parameters_en":[{"name":"Range","range":"(10,0 – 90,0)%"}],"search_en":"Sewage sludge Loss on ignition of dry matter (LOI) Gravimetric method Range PN-EN ISO 15935:2022-01 z wyłączeniem pkt 7.4 i 8.2","technique_en":"Gravimetric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(10,0 – 90,0)%"}],"search_zh":"污泥 干物质烧失量（LOI） 重量法 范围 PN-EN ISO 15935:2022-01 z wyłączeniem pkt 7.4 i 8.2","technique_zh":"重量法","test_object_zh":"污泥","methodology_zh":"干物质烧失量（LOI）"},{"_id":"6a82dda1884ede9a1b2c33c2","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość fosforu ogólnego","parameters":[{"name":"Zakres","range":"(1,5 – 50,0) g/kg"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość fosforu ogólnego\nZakres (1,5 – 50,0) g/kg\nMetoda spektrofotometryczna","reference":"PN-EN 14672:2006 | PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010","norm_bases":["PN-EN 14672:2006","PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010"],"lab_section":"Pracownia w Zielonej Górze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość fosforu ogólnego\nZakres (1,5 – 50,0) g/kg\nMetoda spektrofotometryczna PN-EN 14672:2006 | PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010 Osady sciekowe Zawartosc fosforu ogolnego\nZakres (1,5 – 50,0) g/kg\nMetoda spektrofotometryczna PN-EN 14672:2006 | PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010","categories":["water"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus content","parameters_en":[{"name":"Range","range":"(1,5 – 50,0) g/kg"}],"search_en":"Sewage sludge Total phosphorus content Spectrophotometric method Range PN-EN 14672:2006 | PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(1,5 – 50,0) g/kg"}],"search_zh":"污泥 总磷含量 分光光度法 范围 PN-EN 14672:2006 | PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"污泥","methodology_zh":"总磷含量"},{"_id":"6a82dda1884ede9a1b2c33c3","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość azotu ogólnego Kjeldahla","parameters":[{"name":"Zakres","range":"(1,0 – 100) g/kg"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu ogólnego Kjeldahla\nZakres (1,0 – 100) g/kg\nMetoda miareczkowa","reference":"PN-EN 13342:2002 | PN-EN 25663:2001","norm_bases":["PN-EN 13342:2002","PN-EN 25663:2001"],"lab_section":"Pracownia w Zielonej Górze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość azotu ogólnego Kjeldahla\nZakres (1,0 – 100) g/kg\nMetoda miareczkowa PN-EN 13342:2002 | PN-EN 25663:2001 Osady sciekowe Zawartosc azotu ogolnego Kjeldahla\nZakres (1,0 – 100) g/kg\nMetoda miareczkowa PN-EN 13342:2002 | PN-EN 25663:2001","categories":["water"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total Kjeldahl nitrogen content","parameters_en":[{"name":"Range","range":"(1,0 – 100) g/kg"}],"search_en":"Sewage sludge Total Kjeldahl nitrogen content Titrimetric method Range PN-EN 13342:2002 | PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(1,0 – 100) g/kg"}],"search_zh":"污泥 凯氏总氮含量 滴定法 范围 PN-EN 13342:2002 | PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"污泥","methodology_zh":"凯氏总氮含量"},{"_id":"6a82dda1884ede9a1b2c33c4","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Odpady kod O): 19 08 05","methodology":"Zawartość metali","parameters":[{"name":"miedź","range":"(50 – 2500) mg/kg"},{"name":"kadm","range":"(10 – 100) mg/kg"},{"name":"chrom","range":"(100 – 3000) mg/kg"},{"name":"nikiel","range":"(50 – 2000) mg/kg"},{"name":"ołów","range":"(100 – 2000) mg/kg"},{"name":"cynk","range":"(100 – 5000) mg/kg"},{"name":"wapń","range":"(0,05-20) %"},{"name":"magnez","range":"(0,01-10) %"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość metali\nZakres:\nmiedź (50 – 2500) mg/kg\nkadm (10 – 100) mg/kg\nchrom (100 – 3000) mg/kg\nnikiel (50 – 2000) mg/kg\nołów (100 – 2000) mg/kg\ncynk (100 – 5000) mg/kg\nwapń (0,05-20) %\nmagnez (0,01-10) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 54321:2021-07 | PN-EN ISO 22036:2024-07","norm_bases":["PN-EN ISO 54321:2021-07","PN-EN ISO 22036:2024-07"],"lab_section":"Pracownia w Zielonej Górze","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie stosowania komunalnych osadów ściekowych (tekst jednolity Dz. U. 2023, poz. 23) O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady kod O): 19 08 05 Zawartość metali\nZakres:\nmiedź (50 – 2500) mg/kg\nkadm (10 – 100) mg/kg\nchrom (100 – 3000) mg/kg\nnikiel (50 – 2000) mg/kg\nołów (100 – 2000) mg/kg\ncynk (100 – 5000) mg/kg\nwapń (0,05-20) %\nmagnez (0,01-10) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 54321:2021-07 | PN-EN ISO 22036:2024-07 Odpady kod O): 19 08 05 Zawartosc metali\nZakres:\nmiedz (50 – 2500) mg/kg\nkadm (10 – 100) mg/kg\nchrom (100 – 3000) mg/kg\nnikiel (50 – 2000) mg/kg\nolow (100 – 2000) mg/kg\ncynk (100 – 5000) mg/kg\nwapn (0,05-20) %\nmagnez (0,01-10) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 54321:2021-07 | PN-EN ISO 22036:2024-07","categories":["materials","environment"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal content","parameters_en":[{"name":"copper","range":"(50 – 2500) mg/kg"},{"name":"cadmium","range":"(10 – 100) mg/kg"},{"name":"chromium","range":"(100 – 3000) mg/kg"},{"name":"nickel","range":"(50 – 2000) mg/kg"},{"name":"lead","range":"(100 – 2000) mg/kg"},{"name":"zinc","range":"(100 – 5000) mg/kg"},{"name":"calcium","range":"(0,05-20) %"},{"name":"magnesium","range":"(0,01-10) %"}],"search_en":"Waste code O): 19 08 05 Metal content Inductively coupled plasma optical emission spectrometry (ICP-OES) copper cadmium chromium nickel lead zinc calcium magnesium PN-EN ISO 54321:2021-07 | PN-EN ISO 22036:2024-07","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Waste code O): 19 08 05","parameters_zh":[{"name":"铜","range":"(50 – 2500) mg/kg"},{"name":"镉","range":"(10 – 100) mg/kg"},{"name":"铬","range":"(100 – 3000) mg/kg"},{"name":"镍","range":"(50 – 2000) mg/kg"},{"name":"铅","range":"(100 – 2000) mg/kg"},{"name":"锌","range":"(100 – 5000) mg/kg"},{"name":"钙","range":"(0,05-20) %"},{"name":"镁","range":"(0,01-10) %"}],"search_zh":"废物代码 O)：19 08 05 金属含量 电感耦合等离子体原子发射光谱法（ICP-OES） 铜 镉 铬 镍 铅 锌 钙 镁 PN-EN ISO 54321:2021-07 | PN-EN ISO 22036:2024-07","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","methodology_zh":"金属含量","test_object_zh":"废物代码 O)：19 08 05"},{"_id":"6a82dda1884ede9a1b2c33c5","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Odpady kod O): 19 08 05","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 11,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 11,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":"Pracownia w Zielonej Górze","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie stosowania komunalnych osadów ściekowych (tekst jednolity Dz. U. 2023, poz. 23) O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady kod O): 19 08 05 pH\nZakres 2,0 – 11,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Odpady kod O): 19 08 05 pH\nZakres 2,0 – 11,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["environment"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 11,0"}],"search_en":"Waste code O): 19 08 05 pH Potentiometric method Range PN-EN ISO 10390:2022-09","technique_en":"Potentiometric method","test_object_en":"Waste code O): 19 08 05","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 11,0"}],"search_zh":"废物代码 O)：19 08 05 pH 值 电位法 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法","test_object_zh":"废物代码 O)：19 08 05"},{"_id":"6a82dda1884ede9a1b2c33c6","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Odpady kod O): 19 08 05","methodology":"Sucha pozostałość / zawartość wody","parameters":[{"name":"Zakres","range":"(1,0 – 99) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha pozostałość / zawartość wody\nZakres (1,0 – 99) %\nMetoda wagowa","reference":"PN-EN ISO 11465:2026-03 Metoda A","norm_bases":["PN-EN ISO 11465:2026-03 Metoda A"],"lab_section":"Pracownia w Zielonej Górze","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie stosowania komunalnych osadów ściekowych (tekst jednolity Dz. U. 2023, poz. 23) O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady kod O): 19 08 05 Sucha pozostałość / zawartość wody\nZakres (1,0 – 99) %\nMetoda wagowa PN-EN ISO 11465:2026-03 Metoda A Odpady kod O): 19 08 05 Sucha pozostalosc / zawartosc wody\nZakres (1,0 – 99) %\nMetoda wagowa PN-EN ISO 11465:2026-03 Metoda A","categories":["environment","water"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry residue / water content","parameters_en":[{"name":"Range","range":"(1,0 – 99) %"}],"search_en":"Waste code O): 19 08 05 Dry residue / water content Gravimetric method Range PN-EN ISO 11465:2026-03 Metoda A","technique_en":"Gravimetric method","test_object_en":"Waste code O): 19 08 05","parameters_zh":[{"name":"范围","range":"(1,0 – 99) %"}],"search_zh":"废物代码 O)：19 08 05 干残渣/水分含量 重量法 范围 PN-EN ISO 11465:2026-03 Metoda A","technique_zh":"重量法","methodology_zh":"干残渣/水分含量","test_object_zh":"废物代码 O)：19 08 05"},{"_id":"6a82dda1884ede9a1b2c33c7","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Odpady kod O): 19 08 05","methodology":"Straty przy prażeniu suchej masy (LOI)","parameters":[{"name":"Zakres","range":"(10,0 – 90,0)%"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Straty przy prażeniu suchej masy (LOI)\nZakres (10,0 – 90,0)%\nMetoda wagowa","reference":"PN-EN ISO 15935:2022-01 z wyłączeniem pkt 7.4 i 8.2","norm_bases":["PN-EN ISO 15935:2022-01 z wyłączeniem pkt 7.4 i 8.2"],"lab_section":"Pracownia w Zielonej Górze","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie stosowania komunalnych osadów ściekowych (tekst jednolity Dz. U. 2023, poz. 23) O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady kod O): 19 08 05 Straty przy prażeniu suchej masy (LOI)\nZakres (10,0 – 90,0)%\nMetoda wagowa PN-EN ISO 15935:2022-01 z wyłączeniem pkt 7.4 i 8.2 Odpady kod O): 19 08 05 Straty przy prazeniu suchej masy (LOI)\nZakres (10,0 – 90,0)%\nMetoda wagowa PN-EN ISO 15935:2022-01 z wylaczeniem pkt 7.4 i 8.2","categories":["environment"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Loss on ignition of dry matter (LOI)","parameters_en":[{"name":"Range","range":"(10,0 – 90,0)%"}],"search_en":"Waste code O): 19 08 05 Loss on ignition of dry matter (LOI) Gravimetric method Range PN-EN ISO 15935:2022-01 z wyłączeniem pkt 7.4 i 8.2","technique_en":"Gravimetric method","test_object_en":"Waste code O): 19 08 05","parameters_zh":[{"name":"范围","range":"(10,0 – 90,0)%"}],"search_zh":"废物代码 O)：19 08 05 干物质烧失量（LOI） 重量法 范围 PN-EN ISO 15935:2022-01 z wyłączeniem pkt 7.4 i 8.2","technique_zh":"重量法","methodology_zh":"干物质烧失量（LOI）","test_object_zh":"废物代码 O)：19 08 05"},{"_id":"6a82dda1884ede9a1b2c33c8","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Odpady kod O): 19 08 05","methodology":"Zawartość fosforu ogólnego","parameters":[{"name":"Zakres","range":"(1,5 – 50,0) g/kg"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość fosforu ogólnego\nZakres (1,5 – 50,0) g/kg\nMetoda spektrofotometryczna","reference":"PN-EN 14672:2006 | PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010","norm_bases":["PN-EN 14672:2006","PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010"],"lab_section":"Pracownia w Zielonej Górze","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie stosowania komunalnych osadów ściekowych (tekst jednolity Dz. U. 2023, poz. 23) O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady kod O): 19 08 05 Zawartość fosforu ogólnego\nZakres (1,5 – 50,0) g/kg\nMetoda spektrofotometryczna PN-EN 14672:2006 | PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010 Odpady kod O): 19 08 05 Zawartosc fosforu ogolnego\nZakres (1,5 – 50,0) g/kg\nMetoda spektrofotometryczna PN-EN 14672:2006 | PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010","categories":["environment"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus content","parameters_en":[{"name":"Range","range":"(1,5 – 50,0) g/kg"}],"search_en":"Waste code O): 19 08 05 Total phosphorus content Spectrophotometric method Range PN-EN 14672:2006 | PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Waste code O): 19 08 05","parameters_zh":[{"name":"范围","range":"(1,5 – 50,0) g/kg"}],"search_zh":"废物代码 O)：19 08 05 总磷含量 分光光度法 范围 PN-EN 14672:2006 | PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010","technique_zh":"分光光度法","methodology_zh":"总磷含量","test_object_zh":"废物代码 O)：19 08 05"},{"_id":"6a82dda1884ede9a1b2c33c9","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Odpady kod O): 19 08 05","methodology":"Zawartość azotu ogólnego Kjeldahla","parameters":[{"name":"Zakres","range":"(1,0 – 100) g/kg"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu ogólnego Kjeldahla\nZakres (1,0 – 100) g/kg\nMetoda miareczkowa","reference":"PN-EN 13342:2002 | PN-EN 25663:2001","norm_bases":["PN-EN 13342:2002","PN-EN 25663:2001"],"lab_section":"Pracownia w Zielonej Górze","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie stosowania komunalnych osadów ściekowych (tekst jednolity Dz. U. 2023, poz. 23) O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady kod O): 19 08 05 Zawartość azotu ogólnego Kjeldahla\nZakres (1,0 – 100) g/kg\nMetoda miareczkowa PN-EN 13342:2002 | PN-EN 25663:2001 Odpady kod O): 19 08 05 Zawartosc azotu ogolnego Kjeldahla\nZakres (1,0 – 100) g/kg\nMetoda miareczkowa PN-EN 13342:2002 | PN-EN 25663:2001","categories":["environment"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total Kjeldahl nitrogen content","parameters_en":[{"name":"Range","range":"(1,0 – 100) g/kg"}],"search_en":"Waste code O): 19 08 05 Total Kjeldahl nitrogen content Titrimetric method Range PN-EN 13342:2002 | PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Waste code O): 19 08 05","parameters_zh":[{"name":"范围","range":"(1,0 – 100) g/kg"}],"search_zh":"废物代码 O)：19 08 05 凯氏总氮含量 滴定法 范围 PN-EN 13342:2002 | PN-EN 25663:2001","technique_zh":"滴定法","methodology_zh":"凯氏总氮含量","test_object_zh":"废物代码 O)：19 08 05"},{"_id":"6a82dda1884ede9a1b2c33ca","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Woda","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-4:2017-10 | PN-EN ISO 5667-6:2016-12 (z wyłączeniem p. 7.5.) | PN-ISO 5667-11:2017-10 (z wyłączeniem p.5.2)","norm_bases":["PN-ISO 5667-4:2017-10","PN-EN ISO 5667-6:2016-12 (z wyłączeniem p. 7.5.)","PN-ISO 5667-11:2017-10 (z wyłączeniem p.5.2)"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-4:2017-10 | PN-EN ISO 5667-6:2016-12 (z wyłączeniem p. 7.5.) | PN-ISO 5667-11:2017-10 (z wyłączeniem p.5.2) Woda Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-4:2017-10 | PN-EN ISO 5667-6:2016-12 (z wylaczeniem p. 7.5.) | PN-ISO 5667-11:2017-10 (z wylaczeniem p.5.2)","categories":["water"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Water Sampling for chemical and physical testing PN-ISO 5667-4:2017-10 | PN-EN ISO 5667-6:2016-12 (z wyłączeniem p. 7.5.) | PN-ISO 5667-11:2017-10 (z wyłączeniem p.5.2)","test_object_en":"Water","methodology_zh":"化学与物理检测用样品采集","search_zh":"水 化学与物理检测用样品采集 PN-ISO 5667-4:2017-10 | PN-EN ISO 5667-6:2016-12 (z wyłączeniem p. 7.5.) | PN-ISO 5667-11:2017-10 (z wyłączeniem p.5.2)","test_object_zh":"水"},{"_id":"6a82dda1884ede9a1b2c33cb","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Woda","methodology":"Temperatura","parameters":[{"name":"Zakres","range":"(0,0 – 50,0) ºC"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura\nZakres (0,0 – 50,0) ºC","reference":"PN-77/C-04584","norm_bases":["PN-77/C-04584"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Temperatura\nZakres (0,0 – 50,0) ºC PN-77/C-04584 Woda Temperatura\nZakres (0,0 – 50,0) ºC PN-77/C-04584","categories":["water"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature","parameters_en":[{"name":"Range","range":"(0,0 – 50,0) ºC"}],"search_en":"Water Temperature Range PN-77/C-04584","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,0 – 50,0) ºC"}],"search_zh":"水 温度 范围 PN-77/C-04584","test_object_zh":"水","methodology_zh":"温度"},{"_id":"6a82dda1884ede9a1b2c33cc","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie tlenu rozpuszczonego","parameters":[{"name":"Zakres","range":"(0,5-19,9) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie tlenu rozpuszczonego\nZakres (0,5-19,9) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5814:2013-04","norm_bases":["PN-EN ISO 5814:2013-04"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie tlenu rozpuszczonego\nZakres (0,5-19,9) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5814:2013-04 Woda Stezenie tlenu rozpuszczonego\nZakres (0,5-19,9) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5814:2013-04","categories":["water"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved oxygen concentration","parameters_en":[{"name":"Range","range":"(0,5-19,9) mg/l O2"}],"search_en":"Water Dissolved oxygen concentration Electrochemical method Range PN-EN ISO 5814:2013-04","technique_en":"Electrochemical method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,5-19,9) mg/l O2"}],"search_zh":"水 溶解氧浓度 电化学法 范围 PN-EN ISO 5814:2013-04","technique_zh":"电化学法","test_object_zh":"水","methodology_zh":"溶解氧浓度"},{"_id":"6a82dda1884ede9a1b2c33cd","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie tlenu rozpuszczonego","parameters":[{"name":"Zakres","range":"(0,5-19,9) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Stężenie tlenu rozpuszczonego\nZakres (0,5-19,9) mg/l O2\nMetoda optyczna","reference":"ISO 17289:2014","norm_bases":["ISO 17289:2014"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie tlenu rozpuszczonego\nZakres (0,5-19,9) mg/l O2\nMetoda optyczna ISO 17289:2014 Woda Stezenie tlenu rozpuszczonego\nZakres (0,5-19,9) mg/l O2\nMetoda optyczna ISO 17289:2014","categories":["water"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved oxygen concentration","parameters_en":[{"name":"Range","range":"(0,5-19,9) mg/l O2"}],"search_en":"Water Dissolved oxygen concentration Optical method Range ISO 17289:2014","technique_en":"Optical method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,5-19,9) mg/l O2"}],"search_zh":"水 溶解氧浓度 光学法 范围 ISO 17289:2014","technique_zh":"光学法","test_object_zh":"水","methodology_zh":"溶解氧浓度"},{"_id":"6a82dda1884ede9a1b2c33ce","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Woda","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(10-20000) µS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (10-20000) µS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Przewodność elektryczna właściwa\nZakres (10-20000) µS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda Przewodnosc elektryczna wlasciwa\nZakres (10-20000) µS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(10-20000) µS/cm"}],"search_en":"Water Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(10-20000) µS/cm"}],"search_zh":"水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水"},{"_id":"6a82dda1884ede9a1b2c33cf","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":"Metoda manualna i automatyczna","techniques":["Metoda manualna i automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna i automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna i automatyczna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna i automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":73,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Wastewater Sampling for chemical and physical testing Manual and automatic method PN-ISO 5667-10:2021-11","technique_en":"Manual and automatic method","test_object_en":"Wastewater","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水 化学与物理检测用样品采集 手工与自动法 PN-ISO 5667-10:2021-11","test_object_zh":"污水","technique_zh":"手工与自动法"},{"_id":"6a82dda1884ede9a1b2c33d0","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Ścieki","methodology":"Temperatura","parameters":[{"name":"Zakres","range":"(0,0 – 50,0) ºC"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura\nZakres (0,0 – 50,0) ºC","reference":"PN-77/C-04584","norm_bases":["PN-77/C-04584"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Temperatura\nZakres (0,0 – 50,0) ºC PN-77/C-04584 Scieki Temperatura\nZakres (0,0 – 50,0) ºC PN-77/C-04584","categories":["water"],"row_index":74,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature","parameters_en":[{"name":"Range","range":"(0,0 – 50,0) ºC"}],"search_en":"Wastewater Temperature Range PN-77/C-04584","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(0,0 – 50,0) ºC"}],"search_zh":"污水 温度 范围 PN-77/C-04584","test_object_zh":"污水","methodology_zh":"温度"},{"_id":"6a82dda1884ede9a1b2c33d1","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0-12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0-12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki pH\nZakres 2,0-12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, Scieki pH\nZakres 2,0-12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":75,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0-12,0"}],"search_en":"Water, Wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, Wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0-12,0"}],"search_zh":"水、污水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、污水"},{"_id":"6a82dda1884ede9a1b2c33d2","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Gleba","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009","norm_bases":["PN-ISO 10381-4:2007","PN-ISO 10381-5:2009"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009 Gleba Pobieranie probek do badan chemicznych i fizycznych PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009","categories":["environment"],"row_index":76,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Soil Sampling for chemical and physical testing PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009","test_object_en":"Soil","methodology_zh":"化学与物理检测用样品采集","search_zh":"土壤 化学与物理检测用样品采集 PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009","test_object_zh":"土壤"},{"_id":"6a82dda1884ede9a1b2c33d3","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Pobieranie próbek do badań chemicznych, fizycznych, mikrobiologicznych i parazytologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych, fizycznych, mikrobiologicznych i parazytologicznych","reference":"PN-EN ISO 5667-13:2011 z wyłączeniem p. 6.3.4, p.6.3.5, p.6.3.10","norm_bases":["PN-EN ISO 5667-13:2011 z wyłączeniem p. 6.3.4, p.6.3.5, p.6.3.10"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Pobieranie próbek do badań chemicznych, fizycznych, mikrobiologicznych i parazytologicznych PN-EN ISO 5667-13:2011 z wyłączeniem p. 6.3.4, p.6.3.5, p.6.3.10 Osady sciekowe Pobieranie probek do badan chemicznych, fizycznych, mikrobiologicznych i parazytologicznych PN-EN ISO 5667-13:2011 z wylaczeniem p. 6.3.4, p.6.3.5, p.6.3.10","categories":["water","microbiology"],"row_index":77,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical, physical, microbiological and parasitological testing","search_en":"Sewage sludge Sampling for chemical, physical, microbiological and parasitological testing PN-EN ISO 5667-13:2011 z wyłączeniem p. 6.3.4, p.6.3.5, p.6.3.10","test_object_en":"Sewage sludge","search_zh":"污泥 用于化学、物理、微生物与寄生虫学检验的采样 PN-EN ISO 5667-13:2011 z wyłączeniem p. 6.3.4, p.6.3.5, p.6.3.10","test_object_zh":"污泥","methodology_zh":"用于化学、物理、微生物与寄生虫学检验的采样"},{"_id":"6a82dda1884ede9a1b2c33d4","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(30 – 130) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres (30 – 130) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz. U. z 2023 r., poz. 1706) z wyłączeniem punktu F","norm_bases":["Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz. U. z 2023 r., poz. 1706) z wyłączeniem punktu F"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A\nZakres (30 – 130) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz. U. z 2023 r., poz. 1706) z wyłączeniem punktu F Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A\nZakres (30 – 130) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 7 do rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (tj. Dz. U. z 2023 r., poz. 1706) z wylaczeniem punktu F","categories":["environment"],"row_index":78,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level","parameters_en":[{"name":"Range","range":"(30 – 130) dB"}],"search_en":"General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level Direct measurement method Range Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz. U. z 2023 r., poz. 1706) z wyłączeniem punktu F","technique_en":"Direct measurement method","test_object_en":"General environment – noise from installations, equipment and industrial plants","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(30 – 130) dB"}],"search_zh":"一般环境 – 来自设施、设备与工业企业的噪声 A 计权等效声级 直接测量法 范围 Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz. U. z 2023 r., poz. 1706) z wyłączeniem punktu F","technique_zh":"直接测量法","test_object_zh":"一般环境 – 来自设施、设备与工业企业的噪声"},{"_id":"6a82dda1884ede9a1b2c33d5","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz. U. z 2023 r., poz. 1706) z wyłączeniem punktu F","norm_bases":["Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz. U. z 2023 r., poz. 1706) z wyłączeniem punktu F"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz. U. z 2023 r., poz. 1706) z wyłączeniem punktu F Srodowisko ogolne – halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik nr 7 do rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (tj. Dz. U. z 2023 r., poz. 1706) z wylaczeniem punktu F","categories":["environment"],"row_index":79,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","search_en":"General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz. U. z 2023 r., poz. 1706) z wyłączeniem punktu F","test_object_en":"General environment – noise from installations, equipment and industrial plants","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 – 来自设施、设备与工业企业的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz. U. z 2023 r., poz. 1706) z wyłączeniem punktu F","test_object_zh":"一般环境 – 来自设施、设备与工业企业的噪声"},{"_id":"6a82dda1884ede9a1b2c33d6","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Odpady kod O): 19 08 05","methodology":"Pobieranie próbek do badań chemicznych, fizycznych, mikrobiologicznych i parazytologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych, fizycznych, mikrobiologicznych i parazytologicznych","reference":"PN-EN ISO 5667-13:2011 z wyłączeniem p. 6.3.4, p.6.3.5, p.6.3.10","norm_bases":["PN-EN ISO 5667-13:2011 z wyłączeniem p. 6.3.4, p.6.3.5, p.6.3.10"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 roku w sprawie stosowania komunalnych osadów ściekowych (tekst jednolity Dz. U. 2023, poz. 23) O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","flexible":false,"search_text":"Odpady kod O): 19 08 05 Pobieranie próbek do badań chemicznych, fizycznych, mikrobiologicznych i parazytologicznych PN-EN ISO 5667-13:2011 z wyłączeniem p. 6.3.4, p.6.3.5, p.6.3.10 Odpady kod O): 19 08 05 Pobieranie probek do badan chemicznych, fizycznych, mikrobiologicznych i parazytologicznych PN-EN ISO 5667-13:2011 z wylaczeniem p. 6.3.4, p.6.3.5, p.6.3.10","categories":["environment","microbiology"],"row_index":80,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical, physical, microbiological and parasitological testing","search_en":"Waste code O): 19 08 05 Sampling for chemical, physical, microbiological and parasitological testing PN-EN ISO 5667-13:2011 z wyłączeniem p. 6.3.4, p.6.3.5, p.6.3.10","test_object_en":"Waste code O): 19 08 05","methodology_zh":"用于化学、物理、微生物与寄生虫学检验的采样","search_zh":"废物代码 O)：19 08 05 用于化学、物理、微生物与寄生虫学检验的采样 PN-EN ISO 5667-13:2011 z wyłączeniem p. 6.3.4, p.6.3.5, p.6.3.10","test_object_zh":"废物代码 O)：19 08 05"},{"_id":"6a82dda1884ede9a1b2c33d7","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe)","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"- w zakresie częstotliwości","range":"od 80 MHz do 60000 MHz"},{"name":"Zakres","range":"(0,5 – 200) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\n- w zakresie częstotliwości od 80 MHz do 60000 MHz\nZakres (0,5 – 200) V/m\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natężenie pola elektrycznego:\nZakres:\n- w zakresie częstotliwości od 80 MHz do 60000 MHz\nZakres (0,5 – 200) V/m\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natezenie pola elektrycznego:\nZakres:\n- w zakresie czestotliwosci od 80 MHz do 60000 MHz\nZakres (0,5 – 200) V/m\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","categories":["environment"],"row_index":81,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength:","parameters_en":[{"name":"- w zakresie częstotliwości","range":"od 80 MHz do 60000 MHz"},{"name":"Range","range":"(0,5 – 200) V/m"}],"search_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Electric field strength: Direct measurement method Range Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","technique_en":"Direct measurement method","test_object_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements)","methodology_zh":"电场强度：","parameters_zh":[{"name":"- w zakresie częstotliwości","range":"od 80 MHz do 60000 MHz"},{"name":"范围","range":"(0,5 – 200) V/m"}],"search_zh":"环境 – 无线电通信设施周围的电磁场（宽带测量） 电场强度： 直接测量法 范围 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","technique_zh":"直接测量法","test_object_zh":"环境 – 无线电通信设施周围的电磁场（宽带测量）"},{"_id":"6a82dda1884ede9a1b2c33d8","lab_id":"69ad52a3de79e566650fb12d","country":"PL","accr_number":"AB 127","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe)","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"- w zakresie częstotliwości","range":"od 80 MHz do 60000 MHz"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\n- w zakresie częstotliwości od 80 MHz do 60000 MHz\n(z obliczeń)","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natężenie pola magnetycznego:\nZakres:\n- w zakresie częstotliwości od 80 MHz do 60000 MHz\n(z obliczeń) Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych (pomiary szerokopasmowe) Natezenie pola magnetycznego:\nZakres:\n- w zakresie czestotliwosci od 80 MHz do 60000 MHz\n(z obliczen) Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","categories":["environment"],"row_index":82,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"- w zakresie częstotliwości","range":"od 80 MHz do 60000 MHz"},{"name":"(calculated)"}],"search_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements) Magnetic field strength: (calculated) Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","test_object_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations (broadband measurements)","methodology_zh":"磁场强度：","parameters_zh":[{"name":"- w zakresie częstotliwości","range":"od 80 MHz do 60000 MHz"},{"name":"（计算得出）"}],"search_zh":"环境 – 无线电通信设施周围的电磁场（宽带测量） 磁场强度： （计算得出） Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","test_object_zh":"环境 – 无线电通信设施周围的电磁场（宽带测量）"}],"has_pdf":true}