🇵🇱 KATARZYNA ROKOSSOWSKA PL
EnvironmentElectronics & EMCAutomotive
KATARZYNA ROKOSSOWSKA is a laboratory accredited by PCA under number AB 1263 (Poznań, Poland). Its accreditation scope covers 23 test methods in the following areas: Environment, Electronics & EMC, Automotive. Test objects include: Workplace environment − electromagnetic field from equipment used i…, Workplace environment − electromagnetic field from industrial insta…, Workplace environment − electromagnetic field originating from radi…, Environment – electromagnetic field in the vicinity of electric pow…. Most frequently used techniques: Direct measurement method, Calculation method.
At a glance
- Accreditation number: PCA AB 1263
- Methods in scope: 23
- Types of test objects: 7
- Techniques used: 2
- City: Poznań, Poland
- Accreditation number
- AB 1263
- Accreditation body
- PCA
- Address
- PRZEDSIĘBIORSTWO USŁUGOWE „LAB-TOP”, Daszewice, ul. Pogodna 7/3, 61-160 Poznań
- City
- Poznań, Poland
What this laboratory tests (7)
- Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units - magnetic resonance scanners — 4 methods
- Workplace environment − electromagnetic field from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters - industrial static field sources — 4 methods
- Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: - handheld radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) — 4 methods
- Environment – electromagnetic field in the vicinity of electric power substations and power lines — 3 methods
- Workplace environment – electromagnetic field in the workspace during the use of magnetotherapy or magnetostimulation devices — 3 methods
- Workplace environment – electromagnetic field in the workspace during the use of power systems and alternating current electrical supply installations in the power industry — 3 methods
- Environment – electromagnetic field (electromagnetic overhead lines without voltage limitation) — 2 methods
Analytical techniques used (2)
- Direct measurement method — 15 methods
- Calculation method — 2 methods
Laboratory locations
- Laboratorium Badań Czynników Fizycznych LAB-TOP — ul. Forteczna 17
Accreditation scope — test methods (23)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Laboratorium Badań Czynników Fizycznych LAB-TOP | |||||
| 1 | Environment – electromagnetic field in the vicinity of electric power substations and power lines | Electric field strength: in the frequency range 50 Hz Range 0,1 kV/m – 50 kV/m Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | |
| 2 | Environment – electromagnetic field in the vicinity of electric power substations and power lines | Magnetic flux density: in the frequency range 50 Hz Range 0,02 µT – 10 mT Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | |
| 3 | Environment – electromagnetic field in the vicinity of electric power substations and power lines | Magnetic field strength: in the frequency range 50 Hz (calculated) Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | ||
| 4 | Workplace environment – electromagnetic field in the workspace during the use of power systems and alternating current electrical supply installations in the power industry | Electric field strength: in the frequency range od 5 Hz do 1000 Hz Range 1 V/m – 50 kV/m Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331). |
Direct measurement method | Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91–150 | |
| 5 | Workplace environment – electromagnetic field in the workspace during the use of power systems and alternating current electrical supply installations in the power industry | Magnetic flux density: in the frequency range od 5 Hz do 1000 Hz Range 0,02 µT – 10 mT Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331). |
Direct measurement method | Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91–150 | |
| 6 | Workplace environment – electromagnetic field in the workspace during the use of power systems and alternating current electrical supply installations in the power industry | Magnetic field strength: in the frequency range od 5 Hz do 1000 Hz (calculated) Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331). |
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91–150 | ||
| 7 | Workplace environment – electromagnetic field in the workspace during the use of magnetotherapy or magnetostimulation devices | Electric field strength: in the frequency range od 5 Hz do 400 kHz Range 1 V/m – 50 kV/m Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331). |
Direct measurement method | Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151–180 | |
| 8 | Workplace environment – electromagnetic field in the workspace during the use of magnetotherapy or magnetostimulation devices | Magnetic flux density: in the frequency range od 5 Hz do 400 kHz Range 0,02 µT – 10 mT Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331). |
Direct measurement method | Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151–180 | |
| 9 | Workplace environment – electromagnetic field in the workspace during the use of magnetotherapy or magnetostimulation devices | Magnetic field strength: in the frequency range od 5 Hz do 400 kHz (calculated) Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331). |
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151–180 | ||
| 10 | Workplace environment − electromagnetic field from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters - industrial static field sources | Electric field strength: in the frequency range od 5 Hz do 400 kHz Range 1 V/m – 50 kV/m in the frequency range od 100 kHz do 18 GHz Range (0,5 – 900) V/m |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-01 wydanie 5 z dnia 31.07.2026 r. | |
| 11 | Workplace environment − electromagnetic field from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters - industrial static field sources | Magnetic flux density: in the frequency range 0 Hz Range 200 µT – 1200 mT in the frequency range od 5 Hz do 400 kHz Range 0,02 µT – 12 mT |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-01 wydanie 5 z dnia 31.07.2026 r. | |
| 12 | Workplace environment − electromagnetic field from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters - industrial static field sources | Magnetic field strength: in the frequency range od 20 Hz do 20 kHz Range 1,6 A/m – 7 kA/m in the frequency range od 0,3 MHz do 30 MHz Range (0,0105 – 16) A/m in the frequency range od 0,026 GHz do 1,0 GHz Range (0,013 – 4,2) A/m |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-01 wydanie 5 z dnia 31.07.2026 r. | |
| 13 | Workplace environment − electromagnetic field from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters - industrial static field sources | Magnetic field strength: in the frequency range 0 Hz in the frequency range od 5 Hz do 400 kHz in the frequency range od 1 GHz do 18 GHz (calculated) |
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-01 wydanie 5 z dnia 31.07.2026 r. | ||
| 14 | Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: - handheld radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) | Electric field strength: in the frequency range od 5 Hz do 400 kHz Range 1 V/m – 50 kV/m in the frequency range od 100 kHz do 18 GHz Range (0,5 – 900) V/m |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-04 wydanie 2 z dnia 31.07.2026 r. | |
| 15 | Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: - handheld radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) | Magnetic flux density: in the frequency range 0 Hz Range 200 µT – 1200 mT in the frequency range od 5 Hz do 400 kHz Range 0,02 µT – 12 mT |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-04 wydanie 2 z dnia 31.07.2026 r. | |
| 16 | Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: - handheld radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) | Magnetic field strength: in the frequency range od 20 Hz do 20 kHz Range 1,6 A/m – 7 kA/m in the frequency range od 0,3 MHz do 30 MHz Range (0,0105 – 16) A/m in the frequency range od 0,026 GHz do 1,0 GHz Range (0,013 – 4,2) A/m |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-04 wydanie 2 z dnia 31.07.2026 r. | |
| 17 | Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: - handheld radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) | Magnetic field strength: in the frequency range 0 Hz in the frequency range od 5 Hz do 400 kHz in the frequency range od 1 GHz do 18 GHz (calculated) |
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-04 wydanie 2 z dnia 31.07.2026 r. | ||
| 18 | Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units - magnetic resonance scanners | Electric field strength: in the frequency range od 5 Hz do 400 kHz Range 1 V/m – 50 kV/m in the frequency range od 100 kHz do 18 GHz Range (0,5 – 900) V/m |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-02 wydanie 5 z dnia 31.07.2026 r. | |
| 19 | Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units - magnetic resonance scanners | Magnetic flux density: in the frequency range 0 Hz Range 200 µT – 1200 mT in the frequency range od 5 Hz do 400 kHz Range 0,02 µT – 12 mT |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-02 wydanie 5 z dnia 31.07.2026 r. | |
| 20 | Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units - magnetic resonance scanners | Magnetic field strength: in the frequency range od 20 Hz do 20 kHz Range 1,6 A/m – 7 kA/m in the frequency range od 0,3 MHz do 30 MHz Range (0,0105 – 16) A/m in the frequency range od 0,026 GHz do 1,0 GHz Range (0,013 – 4,2) A/m |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-02 wydanie 5 z dnia 31.07.2026 r. | |
| 21 | Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units - magnetic resonance scanners | Magnetic field strength: in the frequency range 0 Hz in the frequency range od 5 Hz do 400 kHz in the frequency range od 1 GHz do 18 GHz (calculated) |
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-02 wydanie 5 z dnia 31.07.2026 r. | ||
| 22 | Environment – electromagnetic field (electromagnetic overhead lines without voltage limitation) | Electric field strength o częstotliwości 50 Hz |
Calculation method | Procedura badawcza PB-02 wydanie 3 z dnia 31.07.2026 r. | |
| 23 | Environment – electromagnetic field (electromagnetic overhead lines without voltage limitation) | Magnetic field strength o częstotliwości 50 Hz |
Calculation method | Procedura badawcza PB-02 wydanie 3 z dnia 31.07.2026 r. | |
Reference standards (8)
Instrukcja IB-02_Z-01 wydanie 5 z dnia 31.07.2026 r.
Instrukcja IB-02_Z-02 wydanie 5 z dnia 31.07.2026 r.
Instrukcja IB-02_Z-04 wydanie 2 z dnia 31.07.2026 r.
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151–180
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91–150
Procedura badawcza PB-02 wydanie 3 z dnia 31.07.2026 r.
Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)