🇵🇱 KATARZYNA ROKOSSOWSKA PL

PCA AB 1263 • Poznań, Poland • 23 methods

EnvironmentElectronics & EMCAutomotive

KATARZYNA ROKOSSOWSKA is a laboratory accredited by PCA under number AB 1263 (Poznań, Poland). Its accreditation scope covers 23 test methods in the following areas: Environment, Electronics & EMC, Automotive. Test objects include: Workplace environment − electromagnetic field from equipment used i…, Workplace environment − electromagnetic field from industrial insta…, Workplace environment − electromagnetic field originating from radi…, Environment – electromagnetic field in the vicinity of electric pow…. Most frequently used techniques: Direct measurement method, Calculation method.

At a glance

  • Accreditation number: PCA AB 1263
  • Methods in scope: 23
  • Types of test objects: 7
  • Techniques used: 2
  • City: Poznań, Poland
Accreditation number
AB 1263
Accreditation body
PCA
Address
PRZEDSIĘBIORSTWO USŁUGOWE „LAB-TOP”, Daszewice, ul. Pogodna 7/3, 61-160 Poznań
City
Poznań, Poland

What this laboratory tests (7)

Analytical techniques used (2)

Laboratory locations

Accreditation scope — test methods (23)

No. Test object Methodology / Parameters Technique Reference document
Laboratorium Badań Czynników Fizycznych LAB-TOP
1 Environment – electromagnetic field in the vicinity of electric power substations and power lines Electric field strength:
in the frequency range 50 Hz Range 0,1 kV/m – 50 kV/m
Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Direct measurement method Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
2 Environment – electromagnetic field in the vicinity of electric power substations and power lines Magnetic flux density:
in the frequency range 50 Hz Range 0,02 µT – 10 mT
Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Direct measurement method Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
3 Environment – electromagnetic field in the vicinity of electric power substations and power lines Magnetic field strength:
in the frequency range 50 Hz (calculated)
Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
4 Workplace environment – electromagnetic field in the workspace during the use of power systems and alternating current electrical supply installations in the power industry Electric field strength:
in the frequency range od 5 Hz do 1000 Hz Range 1 V/m – 50 kV/m
Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331).
Direct measurement method Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91–150
5 Workplace environment – electromagnetic field in the workspace during the use of power systems and alternating current electrical supply installations in the power industry Magnetic flux density:
in the frequency range od 5 Hz do 1000 Hz Range 0,02 µT – 10 mT
Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331).
Direct measurement method Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91–150
6 Workplace environment – electromagnetic field in the workspace during the use of power systems and alternating current electrical supply installations in the power industry Magnetic field strength:
in the frequency range od 5 Hz do 1000 Hz (calculated)
Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331).
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91–150
7 Workplace environment – electromagnetic field in the workspace during the use of magnetotherapy or magnetostimulation devices Electric field strength:
in the frequency range od 5 Hz do 400 kHz Range 1 V/m – 50 kV/m
Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331).
Direct measurement method Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151–180
8 Workplace environment – electromagnetic field in the workspace during the use of magnetotherapy or magnetostimulation devices Magnetic flux density:
in the frequency range od 5 Hz do 400 kHz Range 0,02 µT – 10 mT
Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331).
Direct measurement method Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151–180
9 Workplace environment – electromagnetic field in the workspace during the use of magnetotherapy or magnetostimulation devices Magnetic field strength:
in the frequency range od 5 Hz do 400 kHz (calculated)
Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331).
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151–180
10 Workplace environment − electromagnetic field from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters - industrial static field sources Electric field strength:
in the frequency range od 5 Hz do 400 kHz Range 1 V/m – 50 kV/m in the frequency range od 100 kHz do 18 GHz Range (0,5 – 900) V/m
Direct measurement method PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-01 wydanie 5 z dnia 31.07.2026 r.
11 Workplace environment − electromagnetic field from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters - industrial static field sources Magnetic flux density:
in the frequency range 0 Hz Range 200 µT – 1200 mT in the frequency range od 5 Hz do 400 kHz Range 0,02 µT – 12 mT
Direct measurement method PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-01 wydanie 5 z dnia 31.07.2026 r.
12 Workplace environment − electromagnetic field from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters - industrial static field sources Magnetic field strength:
in the frequency range od 20 Hz do 20 kHz Range 1,6 A/m – 7 kA/m in the frequency range od 0,3 MHz do 30 MHz Range (0,0105 – 16) A/m in the frequency range od 0,026 GHz do 1,0 GHz Range (0,013 – 4,2) A/m
Direct measurement method PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-01 wydanie 5 z dnia 31.07.2026 r.
13 Workplace environment − electromagnetic field from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters - industrial static field sources Magnetic field strength:
in the frequency range 0 Hz in the frequency range od 5 Hz do 400 kHz in the frequency range od 1 GHz do 18 GHz (calculated)
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-01 wydanie 5 z dnia 31.07.2026 r.
14 Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: - handheld radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) Electric field strength:
in the frequency range od 5 Hz do 400 kHz Range 1 V/m – 50 kV/m in the frequency range od 100 kHz do 18 GHz Range (0,5 – 900) V/m
Direct measurement method PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-04 wydanie 2 z dnia 31.07.2026 r.
15 Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: - handheld radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) Magnetic flux density:
in the frequency range 0 Hz Range 200 µT – 1200 mT in the frequency range od 5 Hz do 400 kHz Range 0,02 µT – 12 mT
Direct measurement method PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-04 wydanie 2 z dnia 31.07.2026 r.
16 Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: - handheld radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) Magnetic field strength:
in the frequency range od 20 Hz do 20 kHz Range 1,6 A/m – 7 kA/m in the frequency range od 0,3 MHz do 30 MHz Range (0,0105 – 16) A/m in the frequency range od 0,026 GHz do 1,0 GHz Range (0,013 – 4,2) A/m
Direct measurement method PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-04 wydanie 2 z dnia 31.07.2026 r.
17 Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: - handheld radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) Magnetic field strength:
in the frequency range 0 Hz in the frequency range od 5 Hz do 400 kHz in the frequency range od 1 GHz do 18 GHz (calculated)
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-04 wydanie 2 z dnia 31.07.2026 r.
18 Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units - magnetic resonance scanners Electric field strength:
in the frequency range od 5 Hz do 400 kHz Range 1 V/m – 50 kV/m in the frequency range od 100 kHz do 18 GHz Range (0,5 – 900) V/m
Direct measurement method PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-02 wydanie 5 z dnia 31.07.2026 r.
19 Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units - magnetic resonance scanners Magnetic flux density:
in the frequency range 0 Hz Range 200 µT – 1200 mT in the frequency range od 5 Hz do 400 kHz Range 0,02 µT – 12 mT
Direct measurement method PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-02 wydanie 5 z dnia 31.07.2026 r.
20 Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units - magnetic resonance scanners Magnetic field strength:
in the frequency range od 20 Hz do 20 kHz Range 1,6 A/m – 7 kA/m in the frequency range od 0,3 MHz do 30 MHz Range (0,0105 – 16) A/m in the frequency range od 0,026 GHz do 1,0 GHz Range (0,013 – 4,2) A/m
Direct measurement method PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-02 wydanie 5 z dnia 31.07.2026 r.
21 Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units - magnetic resonance scanners Magnetic field strength:
in the frequency range 0 Hz in the frequency range od 5 Hz do 400 kHz in the frequency range od 1 GHz do 18 GHz (calculated)
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-02 wydanie 5 z dnia 31.07.2026 r.
22 Environment – electromagnetic field (electromagnetic overhead lines without voltage limitation) Electric field strength
o częstotliwości 50 Hz
Calculation method Procedura badawcza PB-02 wydanie 3 z dnia 31.07.2026 r.
23 Environment – electromagnetic field (electromagnetic overhead lines without voltage limitation) Magnetic field strength
o częstotliwości 50 Hz
Calculation method Procedura badawcza PB-02 wydanie 3 z dnia 31.07.2026 r.

Reference standards (8)

Instrukcja IB-02_Z-01 wydanie 5 z dnia 31.07.2026 r.
Instrukcja IB-02_Z-02 wydanie 5 z dnia 31.07.2026 r.
Instrukcja IB-02_Z-04 wydanie 2 z dnia 31.07.2026 r.
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151–180
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91–150
Procedura badawcza PB-02 wydanie 3 z dnia 31.07.2026 r.
Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)