{"lab":{"_id":"69ad52a3de79e566650fb676","accr_number":"AB 1263","country":"PL","accr_body":"PCA","address":"PRZEDSIĘBIORSTWO USŁUGOWE „LAB-TOP”, Daszewice, ul. Pogodna 7/3, 61-160 Poznań","categories":["environment","automotive"],"city":"Poznań","imported_at":"2026-03-08T10:42:43.265Z","methods_count":23,"name":"KATARZYNA ROKOSSOWSKA","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1263.pdf"],"scope_summary":"","search_text":"katarzyna rokossowska przedsiębiorstwo usługowe „lab-top”, daszewice, ul. pogodna 7/3, 61-160 poznań environment metrology pharma electronics other materials automotive","status":"active","updated_at":"2026-03-08T14:50:26.111Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T09:13:05.905Z","email_confidence":"high","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%201263,podmiot.html","parse_date":"2026-08-17T09:13:05.905Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe – pole elektromagnetyczne)","en":"Tests concerning environmental engineering (environmental and climatic) – working environment (harmful factors – electromagnetic field)"},{"codes":"G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko ogólne (czynniki fizyczne – pole elektromagnetyczne)","en":"Tests concerning environmental engineering (environmental and climatic) – general environment (physical factors - electromagnetic field)"}],"issue":{"no":"20","date":"07.08.2026"},"map_coord":[52.29275,16.96062],"map_geo":"nominatim-street","lab_locations":[{"name":"Laboratorium Badań Czynników Fizycznych LAB-TOP","address":"ul. Forteczna 17","city":"Poznań","postal":"61-362"}],"scope_format":"PCA::pracownie+siatka5","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/ecff03cd2c9f8e2a14f8a327cd51853c/AB%201263.pdf","has_en":true,"category_counts":{"environment":23,"automotive":4},"category_scores":{"environment":19.59,"automotive":0.59},"has_zh":true},"methods":[{"_id":"6a82d0a1884ede9a1b2c30d4","lab_id":"69ad52a3de79e566650fb676","country":"PL","accr_number":"AB 1263","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"w zakresie częstotliwości","range":"50 Hz"},{"name":"Zakres","range":"0,1 kV/m – 50 kV/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości 50 Hz\nZakres 0,1 kV/m – 50 kV/m\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":"Laboratorium Badań Czynników Fizycznych LAB-TOP","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości 50 Hz\nZakres 0,1 kV/m – 50 kV/m\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci 50 Hz\nZakres 0,1 kV/m – 50 kV/m\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength:","parameters_en":[{"name":"in the frequency range","range":"50 Hz"},{"name":"Range","range":"0,1 kV/m – 50 kV/m"}],"search_en":"Environment – electromagnetic field in the vicinity of electric power substations and power lines Electric field strength: Direct measurement method in the frequency range Range Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_en":"Direct measurement method","test_object_en":"Environment – electromagnetic field in the vicinity of electric power substations and power lines","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围","range":"50 Hz"},{"name":"范围","range":"0,1 kV/m – 50 kV/m"}],"search_zh":"环境 — 变电站与输电线路周围的电磁场 电场强度： 直接测量法 频率范围 范围 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_zh":"直接测量法","test_object_zh":"环境 — 变电站与输电线路周围的电磁场"},{"_id":"6a82d0a1884ede9a1b2c30d5","lab_id":"69ad52a3de79e566650fb676","country":"PL","accr_number":"AB 1263","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych","methodology":"Indukcja magnetyczna:","parameters":[{"name":"w zakresie częstotliwości","range":"50 Hz"},{"name":"Zakres","range":"0,02 µT – 10 mT"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości 50 Hz\nZakres 0,02 µT – 10 mT\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":"Laboratorium Badań Czynników Fizycznych LAB-TOP","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości 50 Hz\nZakres 0,02 µT – 10 mT\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Indukcja magnetyczna:\nZakres:\nw zakresie czestotliwosci 50 Hz\nZakres 0,02 µT – 10 mT\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic flux density:","parameters_en":[{"name":"in the frequency range","range":"50 Hz"},{"name":"Range","range":"0,02 µT – 10 mT"}],"search_en":"Environment – electromagnetic field in the vicinity of electric power substations and power lines Magnetic flux density: Direct measurement method in the frequency range Range Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_en":"Direct measurement method","test_object_en":"Environment – electromagnetic field in the vicinity of electric power substations and power lines","parameters_zh":[{"name":"频率范围","range":"50 Hz"},{"name":"范围","range":"0,02 µT – 10 mT"}],"search_zh":"环境 — 变电站与输电线路周围的电磁场 磁感应强度： 直接测量法 频率范围 范围 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_zh":"直接测量法","test_object_zh":"环境 — 变电站与输电线路周围的电磁场","methodology_zh":"磁感应强度："},{"_id":"6a82d0a1884ede9a1b2c30d6","lab_id":"69ad52a3de79e566650fb676","country":"PL","accr_number":"AB 1263","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości","range":"50 Hz"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości 50 Hz\n(z obliczeń)","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":"Laboratorium Badań Czynników Fizycznych LAB-TOP","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości 50 Hz\n(z obliczeń) Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci 50 Hz\n(z obliczen) Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"in the frequency range","range":"50 Hz"},{"name":"(calculated)"}],"search_en":"Environment – electromagnetic field in the vicinity of electric power substations and power lines Magnetic field strength: in the frequency range (calculated) Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","test_object_en":"Environment – electromagnetic field in the vicinity of electric power substations and power lines","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围","range":"50 Hz"},{"name":"（计算得出）"}],"search_zh":"环境 — 变电站与输电线路周围的电磁场 磁场强度： 频率范围 （计算得出） Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","test_object_zh":"环境 — 变电站与输电线路周围的电磁场"},{"_id":"6a82d0a1884ede9a1b2c30d7","lab_id":"69ad52a3de79e566650fb676","country":"PL","accr_number":"AB 1263","accr_body":"PCA","test_object":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas użytkowania systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"w zakresie częstotliwości","range":"od 5 Hz do 1000 Hz"},{"name":"Zakres","range":"1 V/m – 50 kV/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 5 Hz do 1000 Hz\nZakres 1 V/m – 50 kV/m\nMetoda pomiarowa bezpośrednia","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91–150","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91–150"],"lab_section":"Laboratorium Badań Czynników Fizycznych LAB-TOP","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331).","flexible":false,"search_text":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas użytkowania systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 5 Hz do 1000 Hz\nZakres 1 V/m – 50 kV/m\nMetoda pomiarowa bezpośrednia Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91–150 Srodowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas uzytkowania systemow elektroenergetycznych i elektrycznych instalacji zasilajacych pradu przemiennego w energetyce Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 5 Hz do 1000 Hz\nZakres 1 V/m – 50 kV/m\nMetoda pomiarowa bezposrednia Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4 (90), s. 91–150","categories":["environment"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength:","parameters_en":[{"name":"in the frequency range","range":"od 5 Hz do 1000 Hz"},{"name":"Range","range":"1 V/m – 50 kV/m"}],"search_en":"Workplace environment – electromagnetic field in the workspace during the use of power systems and alternating current electrical supply installations in the power industry Electric field strength: Direct measurement method in the frequency range Range Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91–150","technique_en":"Direct measurement method","test_object_en":"Workplace environment – electromagnetic field in the workspace during the use of power systems and alternating current electrical supply installations in the power industry","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围","range":"od 5 Hz do 1000 Hz"},{"name":"范围","range":"1 V/m – 50 kV/m"}],"search_zh":"工作环境 － 使用电力系统与电力行业交流供电电气装置时作业空间内的电磁场 电场强度： 直接测量法 频率范围 范围 Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91–150","technique_zh":"直接测量法","test_object_zh":"工作环境 － 使用电力系统与电力行业交流供电电气装置时作业空间内的电磁场"},{"_id":"6a82d0a1884ede9a1b2c30d8","lab_id":"69ad52a3de79e566650fb676","country":"PL","accr_number":"AB 1263","accr_body":"PCA","test_object":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas użytkowania systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce","methodology":"Indukcja magnetyczna:","parameters":[{"name":"w zakresie częstotliwości","range":"od 5 Hz do 1000 Hz"},{"name":"Zakres","range":"0,02 µT – 10 mT"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości od 5 Hz do 1000 Hz\nZakres 0,02 µT – 10 mT\nMetoda pomiarowa bezpośrednia","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91–150","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91–150"],"lab_section":"Laboratorium Badań Czynników Fizycznych LAB-TOP","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331).","flexible":false,"search_text":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas użytkowania systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości od 5 Hz do 1000 Hz\nZakres 0,02 µT – 10 mT\nMetoda pomiarowa bezpośrednia Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91–150 Srodowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas uzytkowania systemow elektroenergetycznych i elektrycznych instalacji zasilajacych pradu przemiennego w energetyce Indukcja magnetyczna:\nZakres:\nw zakresie czestotliwosci od 5 Hz do 1000 Hz\nZakres 0,02 µT – 10 mT\nMetoda pomiarowa bezposrednia Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4 (90), s. 91–150","categories":["environment"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic flux density:","parameters_en":[{"name":"in the frequency range","range":"od 5 Hz do 1000 Hz"},{"name":"Range","range":"0,02 µT – 10 mT"}],"search_en":"Workplace environment – electromagnetic field in the workspace during the use of power systems and alternating current electrical supply installations in the power industry Magnetic flux density: Direct measurement method in the frequency range Range Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91–150","technique_en":"Direct measurement method","test_object_en":"Workplace environment – electromagnetic field in the workspace during the use of power systems and alternating current electrical supply installations in the power industry","parameters_zh":[{"name":"频率范围","range":"od 5 Hz do 1000 Hz"},{"name":"范围","range":"0,02 µT – 10 mT"}],"search_zh":"工作环境 － 使用电力系统与电力行业交流供电电气装置时作业空间内的电磁场 磁感应强度： 直接测量法 频率范围 范围 Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91–150","technique_zh":"直接测量法","methodology_zh":"磁感应强度：","test_object_zh":"工作环境 － 使用电力系统与电力行业交流供电电气装置时作业空间内的电磁场"},{"_id":"6a82d0a1884ede9a1b2c30d9","lab_id":"69ad52a3de79e566650fb676","country":"PL","accr_number":"AB 1263","accr_body":"PCA","test_object":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas użytkowania systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości","range":"od 5 Hz do 1000 Hz"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 5 Hz do 1000 Hz\n(z obliczeń)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91–150","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91–150"],"lab_section":"Laboratorium Badań Czynników Fizycznych LAB-TOP","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331).","flexible":false,"search_text":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas użytkowania systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 5 Hz do 1000 Hz\n(z obliczeń) Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91–150 Srodowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas uzytkowania systemow elektroenergetycznych i elektrycznych instalacji zasilajacych pradu przemiennego w energetyce Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 5 Hz do 1000 Hz\n(z obliczen) Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4 (90), s. 91–150","categories":["environment"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"in the frequency range","range":"od 5 Hz do 1000 Hz"},{"name":"(calculated)"}],"search_en":"Workplace environment – electromagnetic field in the workspace during the use of power systems and alternating current electrical supply installations in the power industry Magnetic field strength: in the frequency range (calculated) Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91–150","test_object_en":"Workplace environment – electromagnetic field in the workspace during the use of power systems and alternating current electrical supply installations in the power industry","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围","range":"od 5 Hz do 1000 Hz"},{"name":"（计算得出）"}],"search_zh":"工作环境 － 使用电力系统与电力行业交流供电电气装置时作业空间内的电磁场 磁场强度： 频率范围 （计算得出） Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91–150","test_object_zh":"工作环境 － 使用电力系统与电力行业交流供电电气装置时作业空间内的电磁场"},{"_id":"6a82d0a1884ede9a1b2c30da","lab_id":"69ad52a3de79e566650fb676","country":"PL","accr_number":"AB 1263","accr_body":"PCA","test_object":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas użytkowania urządzeń do magnetoterapii lub magnetostymulacji","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"w zakresie częstotliwości","range":"od 5 Hz do 400 kHz"},{"name":"Zakres","range":"1 V/m – 50 kV/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 5 Hz do 400 kHz\nZakres 1 V/m – 50 kV/m\nMetoda pomiarowa bezpośrednia","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151–180","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151–180"],"lab_section":"Laboratorium Badań Czynników Fizycznych LAB-TOP","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331).","flexible":false,"search_text":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas użytkowania urządzeń do magnetoterapii lub magnetostymulacji Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 5 Hz do 400 kHz\nZakres 1 V/m – 50 kV/m\nMetoda pomiarowa bezpośrednia Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151–180 Srodowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas uzytkowania urzadzen do magnetoterapii lub magnetostymulacji Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 5 Hz do 400 kHz\nZakres 1 V/m – 50 kV/m\nMetoda pomiarowa bezposrednia Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4 (90), s. 151–180","categories":["environment"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength:","parameters_en":[{"name":"in the frequency range","range":"od 5 Hz do 400 kHz"},{"name":"Range","range":"1 V/m – 50 kV/m"}],"search_en":"Workplace environment – electromagnetic field in the workspace during the use of magnetotherapy or magnetostimulation devices Electric field strength: Direct measurement method in the frequency range Range Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151–180","technique_en":"Direct measurement method","test_object_en":"Workplace environment – electromagnetic field in the workspace during the use of magnetotherapy or magnetostimulation devices","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围","range":"od 5 Hz do 400 kHz"},{"name":"范围","range":"1 V/m – 50 kV/m"}],"search_zh":"工作环境 － 使用磁疗或磁刺激设备时作业空间内的电磁场 电场强度： 直接测量法 频率范围 范围 Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151–180","technique_zh":"直接测量法","test_object_zh":"工作环境 － 使用磁疗或磁刺激设备时作业空间内的电磁场"},{"_id":"6a82d0a1884ede9a1b2c30db","lab_id":"69ad52a3de79e566650fb676","country":"PL","accr_number":"AB 1263","accr_body":"PCA","test_object":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas użytkowania urządzeń do magnetoterapii lub magnetostymulacji","methodology":"Indukcja magnetyczna:","parameters":[{"name":"w zakresie częstotliwości","range":"od 5 Hz do 400 kHz"},{"name":"Zakres","range":"0,02 µT – 10 mT"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości od 5 Hz do 400 kHz\nZakres 0,02 µT – 10 mT\nMetoda pomiarowa bezpośrednia","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151–180","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151–180"],"lab_section":"Laboratorium Badań Czynników Fizycznych LAB-TOP","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331).","flexible":false,"search_text":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas użytkowania urządzeń do magnetoterapii lub magnetostymulacji Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości od 5 Hz do 400 kHz\nZakres 0,02 µT – 10 mT\nMetoda pomiarowa bezpośrednia Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151–180 Srodowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas uzytkowania urzadzen do magnetoterapii lub magnetostymulacji Indukcja magnetyczna:\nZakres:\nw zakresie czestotliwosci od 5 Hz do 400 kHz\nZakres 0,02 µT – 10 mT\nMetoda pomiarowa bezposrednia Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4 (90), s. 151–180","categories":["environment"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic flux density:","parameters_en":[{"name":"in the frequency range","range":"od 5 Hz do 400 kHz"},{"name":"Range","range":"0,02 µT – 10 mT"}],"search_en":"Workplace environment – electromagnetic field in the workspace during the use of magnetotherapy or magnetostimulation devices Magnetic flux density: Direct measurement method in the frequency range Range Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151–180","technique_en":"Direct measurement method","test_object_en":"Workplace environment – electromagnetic field in the workspace during the use of magnetotherapy or magnetostimulation devices","parameters_zh":[{"name":"频率范围","range":"od 5 Hz do 400 kHz"},{"name":"范围","range":"0,02 µT – 10 mT"}],"search_zh":"工作环境 － 使用磁疗或磁刺激设备时作业空间内的电磁场 磁感应强度： 直接测量法 频率范围 范围 Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151–180","technique_zh":"直接测量法","methodology_zh":"磁感应强度：","test_object_zh":"工作环境 － 使用磁疗或磁刺激设备时作业空间内的电磁场"},{"_id":"6a82d0a1884ede9a1b2c30dc","lab_id":"69ad52a3de79e566650fb676","country":"PL","accr_number":"AB 1263","accr_body":"PCA","test_object":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas użytkowania urządzeń do magnetoterapii lub magnetostymulacji","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości","range":"od 5 Hz do 400 kHz"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 5 Hz do 400 kHz\n(z obliczeń)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151–180","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151–180"],"lab_section":"Laboratorium Badań Czynników Fizycznych LAB-TOP","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331).","flexible":false,"search_text":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas użytkowania urządzeń do magnetoterapii lub magnetostymulacji Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 5 Hz do 400 kHz\n(z obliczeń) Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151–180 Srodowisko pracy – pole elektromagnetyczne w przestrzeni pracy podczas uzytkowania urzadzen do magnetoterapii lub magnetostymulacji Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 5 Hz do 400 kHz\n(z obliczen) Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4 (90), s. 151–180","categories":["environment"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"in the frequency range","range":"od 5 Hz do 400 kHz"},{"name":"(calculated)"}],"search_en":"Workplace environment – electromagnetic field in the workspace during the use of magnetotherapy or magnetostimulation devices Magnetic field strength: in the frequency range (calculated) Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151–180","test_object_en":"Workplace environment – electromagnetic field in the workspace during the use of magnetotherapy or magnetostimulation devices","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围","range":"od 5 Hz do 400 kHz"},{"name":"（计算得出）"}],"search_zh":"工作环境 － 使用磁疗或磁刺激设备时作业空间内的电磁场 磁场强度： 频率范围 （计算得出） Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151–180","test_object_zh":"工作环境 － 使用磁疗或磁刺激设备时作业空间内的电磁场"},{"_id":"6a82d0a1884ede9a1b2c30dd","lab_id":"69ad52a3de79e566650fb676","country":"PL","accr_number":"AB 1263","accr_body":"PCA","test_object":"Środowisko pracy − pole elektromagnetyczne od instalacji i urządzeń przemysłowych: - urządzenia do spawania łukowego - zgrzewarki rezystancyjne - przemysłowe magnetyzery i demagnetyzatory - instalacje elekrolityczne - spektrometry NMR - urządzenia do grzania dielektrycznego - urządzenia do grzania indukcyjnego - przemysłowe piece, nagrzewnice i suszarki mikrofalowe, - urządzenia do wytwarzania i przetwarzania tworzyw sztucznych - pojazdy elektryczne - urządzenia do lutowania - elektrodrążarki - piece oporowe i łukowe - generatory i silniki elektryczne - falowniki - przemysłowe źródła pola stałego","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"w zakresie częstotliwości","range":"od 5 Hz do 400 kHz"},{"name":"Zakres","range":"1 V/m – 50 kV/m"},{"name":"w zakresie częstotliwości","range":"od 100 kHz do 18 GHz"},{"name":"Zakres","range":"(0,5 – 900) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 5 Hz do 400 kHz\nZakres 1 V/m – 50 kV/m\nw zakresie częstotliwości od 100 kHz do 18 GHz\nZakres (0,5 – 900) V/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-01 wydanie 5 z dnia 31.07.2026 r.","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","Instrukcja IB-02_Z-01 wydanie 5 z dnia 31.07.2026 r."],"lab_section":"Laboratorium Badań Czynników Fizycznych LAB-TOP","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − pole elektromagnetyczne od instalacji i urządzeń przemysłowych: - urządzenia do spawania łukowego - zgrzewarki rezystancyjne - przemysłowe magnetyzery i demagnetyzatory - instalacje elekrolityczne - spektrometry NMR - urządzenia do grzania dielektrycznego - urządzenia do grzania indukcyjnego - przemysłowe piece, nagrzewnice i suszarki mikrofalowe, - urządzenia do wytwarzania i przetwarzania tworzyw sztucznych - pojazdy elektryczne - urządzenia do lutowania - elektrodrążarki - piece oporowe i łukowe - generatory i silniki elektryczne - falowniki - przemysłowe źródła pola stałego Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 5 Hz do 400 kHz\nZakres 1 V/m – 50 kV/m\nw zakresie częstotliwości od 100 kHz do 18 GHz\nZakres (0,5 – 900) V/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-01 wydanie 5 z dnia 31.07.2026 r. Srodowisko pracy − pole elektromagnetyczne od instalacji i urzadzen przemyslowych: - urzadzenia do spawania lukowego - zgrzewarki rezystancyjne - przemyslowe magnetyzery i demagnetyzatory - instalacje elekrolityczne - spektrometry NMR - urzadzenia do grzania dielektrycznego - urzadzenia do grzania indukcyjnego - przemyslowe piece, nagrzewnice i suszarki mikrofalowe, - urzadzenia do wytwarzania i przetwarzania tworzyw sztucznych - pojazdy elektryczne - urzadzenia do lutowania - elektrodrazarki - piece oporowe i lukowe - generatory i silniki elektryczne - falowniki - przemyslowe zrodla pola stalego Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 5 Hz do 400 kHz\nZakres 1 V/m – 50 kV/m\nw zakresie czestotliwosci od 100 kHz do 18 GHz\nZakres (0,5 – 900) V/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-01 wydanie 5 z dnia 31.07.2026 r.","categories":["environment","automotive"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength:","parameters_en":[{"name":"in the frequency range","range":"od 5 Hz do 400 kHz"},{"name":"Range","range":"1 V/m – 50 kV/m"},{"name":"in the frequency range","range":"od 100 kHz do 18 GHz"},{"name":"Range","range":"(0,5 – 900) V/m"}],"search_en":"Workplace environment − electromagnetic field from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters - industrial static field sources Electric field strength: Direct measurement method in the frequency range Range in the frequency range Range PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-01 wydanie 5 z dnia 31.07.2026 r.","technique_en":"Direct measurement method","test_object_en":"Workplace environment − electromagnetic field from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters - industrial static field sources","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围","range":"od 5 Hz do 400 kHz"},{"name":"范围","range":"1 V/m – 50 kV/m"},{"name":"频率范围","range":"od 100 kHz do 18 GHz"},{"name":"范围","range":"(0,5 – 900) V/m"}],"search_zh":"工作环境 － 来自工业装置与设备的电磁场：－ 弧焊设备 － 电阻焊机 － 工业充磁与退磁装置 － 电解装置 － 核磁共振波谱仪 － 介电加热设备 电场强度： 直接测量法 频率范围 范围 频率范围 范围 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-01 wydanie 5 z dnia 31.07.2026 r.","technique_zh":"直接测量法","test_object_zh":"工作环境 － 来自工业装置与设备的电磁场：－ 弧焊设备 － 电阻焊机 － 工业充磁与退磁装置 － 电解装置 － 核磁共振波谱仪 － 介电加热设备"},{"_id":"6a82d0a1884ede9a1b2c30de","lab_id":"69ad52a3de79e566650fb676","country":"PL","accr_number":"AB 1263","accr_body":"PCA","test_object":"Środowisko pracy − pole elektromagnetyczne od instalacji i urządzeń przemysłowych: - urządzenia do spawania łukowego - zgrzewarki rezystancyjne - przemysłowe magnetyzery i demagnetyzatory - instalacje elekrolityczne - spektrometry NMR - urządzenia do grzania dielektrycznego - urządzenia do grzania indukcyjnego - przemysłowe piece, nagrzewnice i suszarki mikrofalowe, - urządzenia do wytwarzania i przetwarzania tworzyw sztucznych - pojazdy elektryczne - urządzenia do lutowania - elektrodrążarki - piece oporowe i łukowe - generatory i silniki elektryczne - falowniki - przemysłowe źródła pola stałego","methodology":"Indukcja magnetyczna:","parameters":[{"name":"w zakresie częstotliwości","range":"0 Hz"},{"name":"Zakres","range":"200 µT – 1200 mT"},{"name":"w zakresie częstotliwości","range":"od 5 Hz do 400 kHz"},{"name":"Zakres","range":"0,02 µT – 12 mT"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości 0 Hz\nZakres 200 µT – 1200 mT\nw zakresie częstotliwości od 5 Hz do 400 kHz\nZakres 0,02 µT – 12 mT\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-01 wydanie 5 z dnia 31.07.2026 r.","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","Instrukcja IB-02_Z-01 wydanie 5 z dnia 31.07.2026 r."],"lab_section":"Laboratorium Badań Czynników Fizycznych LAB-TOP","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − pole elektromagnetyczne od instalacji i urządzeń przemysłowych: - urządzenia do spawania łukowego - zgrzewarki rezystancyjne - przemysłowe magnetyzery i demagnetyzatory - instalacje elekrolityczne - spektrometry NMR - urządzenia do grzania dielektrycznego - urządzenia do grzania indukcyjnego - przemysłowe piece, nagrzewnice i suszarki mikrofalowe, - urządzenia do wytwarzania i przetwarzania tworzyw sztucznych - pojazdy elektryczne - urządzenia do lutowania - elektrodrążarki - piece oporowe i łukowe - generatory i silniki elektryczne - falowniki - przemysłowe źródła pola stałego Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości 0 Hz\nZakres 200 µT – 1200 mT\nw zakresie częstotliwości od 5 Hz do 400 kHz\nZakres 0,02 µT – 12 mT\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-01 wydanie 5 z dnia 31.07.2026 r. Srodowisko pracy − pole elektromagnetyczne od instalacji i urzadzen przemyslowych: - urzadzenia do spawania lukowego - zgrzewarki rezystancyjne - przemyslowe magnetyzery i demagnetyzatory - instalacje elekrolityczne - spektrometry NMR - urzadzenia do grzania dielektrycznego - urzadzenia do grzania indukcyjnego - przemyslowe piece, nagrzewnice i suszarki mikrofalowe, - urzadzenia do wytwarzania i przetwarzania tworzyw sztucznych - pojazdy elektryczne - urzadzenia do lutowania - elektrodrazarki - piece oporowe i lukowe - generatory i silniki elektryczne - falowniki - przemyslowe zrodla pola stalego Indukcja magnetyczna:\nZakres:\nw zakresie czestotliwosci 0 Hz\nZakres 200 µT – 1200 mT\nw zakresie czestotliwosci od 5 Hz do 400 kHz\nZakres 0,02 µT – 12 mT\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-01 wydanie 5 z dnia 31.07.2026 r.","categories":["environment","automotive"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic flux density:","parameters_en":[{"name":"in the frequency range","range":"0 Hz"},{"name":"Range","range":"200 µT – 1200 mT"},{"name":"in the frequency range","range":"od 5 Hz do 400 kHz"},{"name":"Range","range":"0,02 µT – 12 mT"}],"search_en":"Workplace environment − electromagnetic field from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters - industrial static field sources Magnetic flux density: Direct measurement method in the frequency range Range in the frequency range Range PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-01 wydanie 5 z dnia 31.07.2026 r.","technique_en":"Direct measurement method","test_object_en":"Workplace environment − electromagnetic field from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters - industrial static field sources","parameters_zh":[{"name":"频率范围","range":"0 Hz"},{"name":"范围","range":"200 µT – 1200 mT"},{"name":"频率范围","range":"od 5 Hz do 400 kHz"},{"name":"范围","range":"0,02 µT – 12 mT"}],"search_zh":"工作环境 － 来自工业装置与设备的电磁场：－ 弧焊设备 － 电阻焊机 － 工业充磁与退磁装置 － 电解装置 － 核磁共振波谱仪 － 介电加热设备 磁感应强度： 直接测量法 频率范围 范围 频率范围 范围 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-01 wydanie 5 z dnia 31.07.2026 r.","technique_zh":"直接测量法","methodology_zh":"磁感应强度：","test_object_zh":"工作环境 － 来自工业装置与设备的电磁场：－ 弧焊设备 － 电阻焊机 － 工业充磁与退磁装置 － 电解装置 － 核磁共振波谱仪 － 介电加热设备"},{"_id":"6a82d0a1884ede9a1b2c30df","lab_id":"69ad52a3de79e566650fb676","country":"PL","accr_number":"AB 1263","accr_body":"PCA","test_object":"Środowisko pracy − pole elektromagnetyczne od instalacji i urządzeń przemysłowych: - urządzenia do spawania łukowego - zgrzewarki rezystancyjne - przemysłowe magnetyzery i demagnetyzatory - instalacje elekrolityczne - spektrometry NMR - urządzenia do grzania dielektrycznego - urządzenia do grzania indukcyjnego - przemysłowe piece, nagrzewnice i suszarki mikrofalowe, - urządzenia do wytwarzania i przetwarzania tworzyw sztucznych - pojazdy elektryczne - urządzenia do lutowania - elektrodrążarki - piece oporowe i łukowe - generatory i silniki elektryczne - falowniki - przemysłowe źródła pola stałego","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości","range":"od 20 Hz do 20 kHz"},{"name":"Zakres","range":"1,6 A/m – 7 kA/m"},{"name":"w zakresie częstotliwości","range":"od 0,3 MHz do 30 MHz"},{"name":"Zakres","range":"(0,0105 – 16) A/m"},{"name":"w zakresie częstotliwości","range":"od 0,026 GHz do 1,0 GHz"},{"name":"Zakres","range":"(0,013 – 4,2) A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 20 Hz do 20 kHz\nZakres 1,6 A/m – 7 kA/m\nw zakresie częstotliwości od 0,3 MHz do 30 MHz\nZakres (0,0105 – 16) A/m\nw zakresie częstotliwości od 0,026 GHz do 1,0 GHz\nZakres (0,013 – 4,2) A/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-01 wydanie 5 z dnia 31.07.2026 r.","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","Instrukcja IB-02_Z-01 wydanie 5 z dnia 31.07.2026 r."],"lab_section":"Laboratorium Badań Czynników Fizycznych LAB-TOP","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − pole elektromagnetyczne od instalacji i urządzeń przemysłowych: - urządzenia do spawania łukowego - zgrzewarki rezystancyjne - przemysłowe magnetyzery i demagnetyzatory - instalacje elekrolityczne - spektrometry NMR - urządzenia do grzania dielektrycznego - urządzenia do grzania indukcyjnego - przemysłowe piece, nagrzewnice i suszarki mikrofalowe, - urządzenia do wytwarzania i przetwarzania tworzyw sztucznych - pojazdy elektryczne - urządzenia do lutowania - elektrodrążarki - piece oporowe i łukowe - generatory i silniki elektryczne - falowniki - przemysłowe źródła pola stałego Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 20 Hz do 20 kHz\nZakres 1,6 A/m – 7 kA/m\nw zakresie częstotliwości od 0,3 MHz do 30 MHz\nZakres (0,0105 – 16) A/m\nw zakresie częstotliwości od 0,026 GHz do 1,0 GHz\nZakres (0,013 – 4,2) A/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-01 wydanie 5 z dnia 31.07.2026 r. Srodowisko pracy − pole elektromagnetyczne od instalacji i urzadzen przemyslowych: - urzadzenia do spawania lukowego - zgrzewarki rezystancyjne - przemyslowe magnetyzery i demagnetyzatory - instalacje elekrolityczne - spektrometry NMR - urzadzenia do grzania dielektrycznego - urzadzenia do grzania indukcyjnego - przemyslowe piece, nagrzewnice i suszarki mikrofalowe, - urzadzenia do wytwarzania i przetwarzania tworzyw sztucznych - pojazdy elektryczne - urzadzenia do lutowania - elektrodrazarki - piece oporowe i lukowe - generatory i silniki elektryczne - falowniki - przemyslowe zrodla pola stalego Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 20 Hz do 20 kHz\nZakres 1,6 A/m – 7 kA/m\nw zakresie czestotliwosci od 0,3 MHz do 30 MHz\nZakres (0,0105 – 16) A/m\nw zakresie czestotliwosci od 0,026 GHz do 1,0 GHz\nZakres (0,013 – 4,2) A/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-01 wydanie 5 z dnia 31.07.2026 r.","categories":["environment","automotive"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"in the frequency range","range":"od 20 Hz do 20 kHz"},{"name":"Range","range":"1,6 A/m – 7 kA/m"},{"name":"in the frequency range","range":"od 0,3 MHz do 30 MHz"},{"name":"Range","range":"(0,0105 – 16) A/m"},{"name":"in the frequency range","range":"od 0,026 GHz do 1,0 GHz"},{"name":"Range","range":"(0,013 – 4,2) A/m"}],"search_en":"Workplace environment − electromagnetic field from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters - industrial static field sources Magnetic field strength: Direct measurement method in the frequency range Range in the frequency range Range in the frequency range Range PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-01 wydanie 5 z dnia 31.07.2026 r.","technique_en":"Direct measurement method","test_object_en":"Workplace environment − electromagnetic field from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters - industrial static field sources","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围","range":"od 20 Hz do 20 kHz"},{"name":"范围","range":"1,6 A/m – 7 kA/m"},{"name":"频率范围","range":"od 0,3 MHz do 30 MHz"},{"name":"范围","range":"(0,0105 – 16) A/m"},{"name":"频率范围","range":"od 0,026 GHz do 1,0 GHz"},{"name":"范围","range":"(0,013 – 4,2) A/m"}],"search_zh":"工作环境 － 来自工业装置与设备的电磁场：－ 弧焊设备 － 电阻焊机 － 工业充磁与退磁装置 － 电解装置 － 核磁共振波谱仪 － 介电加热设备 磁场强度： 直接测量法 频率范围 范围 频率范围 范围 频率范围 范围 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-01 wydanie 5 z dnia 31.07.2026 r.","technique_zh":"直接测量法","test_object_zh":"工作环境 － 来自工业装置与设备的电磁场：－ 弧焊设备 － 电阻焊机 － 工业充磁与退磁装置 － 电解装置 － 核磁共振波谱仪 － 介电加热设备"},{"_id":"6a82d0a1884ede9a1b2c30e0","lab_id":"69ad52a3de79e566650fb676","country":"PL","accr_number":"AB 1263","accr_body":"PCA","test_object":"Środowisko pracy − pole elektromagnetyczne od instalacji i urządzeń przemysłowych: - urządzenia do spawania łukowego - zgrzewarki rezystancyjne - przemysłowe magnetyzery i demagnetyzatory - instalacje elekrolityczne - spektrometry NMR - urządzenia do grzania dielektrycznego - urządzenia do grzania indukcyjnego - przemysłowe piece, nagrzewnice i suszarki mikrofalowe, - urządzenia do wytwarzania i przetwarzania tworzyw sztucznych - pojazdy elektryczne - urządzenia do lutowania - elektrodrążarki - piece oporowe i łukowe - generatory i silniki elektryczne - falowniki - przemysłowe źródła pola stałego","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości","range":"0 Hz"},{"name":"w zakresie częstotliwości","range":"od 5 Hz do 400 kHz"},{"name":"w zakresie częstotliwości","range":"od 1 GHz do 18 GHz"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości 0 Hz\nw zakresie częstotliwości od 5 Hz do 400 kHz\nw zakresie częstotliwości od 1 GHz do 18 GHz\n(z obliczeń)","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-01 wydanie 5 z dnia 31.07.2026 r.","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","Instrukcja IB-02_Z-01 wydanie 5 z dnia 31.07.2026 r."],"lab_section":"Laboratorium Badań Czynników Fizycznych LAB-TOP","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − pole elektromagnetyczne od instalacji i urządzeń przemysłowych: - urządzenia do spawania łukowego - zgrzewarki rezystancyjne - przemysłowe magnetyzery i demagnetyzatory - instalacje elekrolityczne - spektrometry NMR - urządzenia do grzania dielektrycznego - urządzenia do grzania indukcyjnego - przemysłowe piece, nagrzewnice i suszarki mikrofalowe, - urządzenia do wytwarzania i przetwarzania tworzyw sztucznych - pojazdy elektryczne - urządzenia do lutowania - elektrodrążarki - piece oporowe i łukowe - generatory i silniki elektryczne - falowniki - przemysłowe źródła pola stałego Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości 0 Hz\nw zakresie częstotliwości od 5 Hz do 400 kHz\nw zakresie częstotliwości od 1 GHz do 18 GHz\n(z obliczeń) PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-01 wydanie 5 z dnia 31.07.2026 r. Srodowisko pracy − pole elektromagnetyczne od instalacji i urzadzen przemyslowych: - urzadzenia do spawania lukowego - zgrzewarki rezystancyjne - przemyslowe magnetyzery i demagnetyzatory - instalacje elekrolityczne - spektrometry NMR - urzadzenia do grzania dielektrycznego - urzadzenia do grzania indukcyjnego - przemyslowe piece, nagrzewnice i suszarki mikrofalowe, - urzadzenia do wytwarzania i przetwarzania tworzyw sztucznych - pojazdy elektryczne - urzadzenia do lutowania - elektrodrazarki - piece oporowe i lukowe - generatory i silniki elektryczne - falowniki - przemyslowe zrodla pola stalego Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci 0 Hz\nw zakresie czestotliwosci od 5 Hz do 400 kHz\nw zakresie czestotliwosci od 1 GHz do 18 GHz\n(z obliczen) PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-01 wydanie 5 z dnia 31.07.2026 r.","categories":["environment","automotive"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"in the frequency range","range":"0 Hz"},{"name":"in the frequency range","range":"od 5 Hz do 400 kHz"},{"name":"in the frequency range","range":"od 1 GHz do 18 GHz"},{"name":"(calculated)"}],"search_en":"Workplace environment − electromagnetic field from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters - industrial static field sources Magnetic field strength: in the frequency range in the frequency range in the frequency range (calculated) PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-01 wydanie 5 z dnia 31.07.2026 r.","test_object_en":"Workplace environment − electromagnetic field from industrial installations and equipment: - arc welding equipment - resistance welding machines - industrial magnetisers and demagnetisers - electrolytic installations - NMR spectrometers - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - electric vehicles - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters - industrial static field sources","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围","range":"0 Hz"},{"name":"频率范围","range":"od 5 Hz do 400 kHz"},{"name":"频率范围","range":"od 1 GHz do 18 GHz"},{"name":"（计算得出）"}],"search_zh":"工作环境 － 来自工业装置与设备的电磁场：－ 弧焊设备 － 电阻焊机 － 工业充磁与退磁装置 － 电解装置 － 核磁共振波谱仪 － 介电加热设备 磁场强度： 频率范围 频率范围 频率范围 （计算得出） PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-01 wydanie 5 z dnia 31.07.2026 r.","test_object_zh":"工作环境 － 来自工业装置与设备的电磁场：－ 弧焊设备 － 电阻焊机 － 工业充磁与退磁装置 － 电解装置 － 核磁共振波谱仪 － 介电加热设备"},{"_id":"6a82d0a1884ede9a1b2c30e1","lab_id":"69ad52a3de79e566650fb676","country":"PL","accr_number":"AB 1263","accr_body":"PCA","test_object":"Środowisko pracy − pole elektromagnetyczne pochodzące od systemów radiokomunikacyjnych i antykradzieżowych: - radiotelefony doręczne, terminale i urządzenia bezprzewodowe krótkiego zasięgu, radiostacje (radiotelefony) nasobne i przewoźne","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"w zakresie częstotliwości","range":"od 5 Hz do 400 kHz"},{"name":"Zakres","range":"1 V/m – 50 kV/m"},{"name":"w zakresie częstotliwości","range":"od 100 kHz do 18 GHz"},{"name":"Zakres","range":"(0,5 – 900) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 5 Hz do 400 kHz\nZakres 1 V/m – 50 kV/m\nw zakresie częstotliwości od 100 kHz do 18 GHz\nZakres (0,5 – 900) V/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-04 wydanie 2 z dnia 31.07.2026 r.","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","Instrukcja IB-02_Z-04 wydanie 2 z dnia 31.07.2026 r."],"lab_section":"Laboratorium Badań Czynników Fizycznych LAB-TOP","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − pole elektromagnetyczne pochodzące od systemów radiokomunikacyjnych i antykradzieżowych: - radiotelefony doręczne, terminale i urządzenia bezprzewodowe krótkiego zasięgu, radiostacje (radiotelefony) nasobne i przewoźne Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 5 Hz do 400 kHz\nZakres 1 V/m – 50 kV/m\nw zakresie częstotliwości od 100 kHz do 18 GHz\nZakres (0,5 – 900) V/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-04 wydanie 2 z dnia 31.07.2026 r. Srodowisko pracy − pole elektromagnetyczne pochodzace od systemow radiokomunikacyjnych i antykradziezowych: - radiotelefony doreczne, terminale i urzadzenia bezprzewodowe krotkiego zasiegu, radiostacje (radiotelefony) nasobne i przewozne Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 5 Hz do 400 kHz\nZakres 1 V/m – 50 kV/m\nw zakresie czestotliwosci od 100 kHz do 18 GHz\nZakres (0,5 – 900) V/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-04 wydanie 2 z dnia 31.07.2026 r.","categories":["environment"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength:","parameters_en":[{"name":"in the frequency range","range":"od 5 Hz do 400 kHz"},{"name":"Range","range":"1 V/m – 50 kV/m"},{"name":"in the frequency range","range":"od 100 kHz do 18 GHz"},{"name":"Range","range":"(0,5 – 900) V/m"}],"search_en":"Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: - handheld radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) Electric field strength: Direct measurement method in the frequency range Range in the frequency range Range PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-04 wydanie 2 z dnia 31.07.2026 r.","technique_en":"Direct measurement method","test_object_en":"Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: - handheld radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones)","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围","range":"od 5 Hz do 400 kHz"},{"name":"范围","range":"1 V/m – 50 kV/m"},{"name":"频率范围","range":"od 100 kHz do 18 GHz"},{"name":"范围","range":"(0,5 – 900) V/m"}],"search_zh":"工作环境 － 无线电通信与防盗系统产生的电磁场：－ 手持对讲机、终端与短距离无线设备、随身与车载电台（对讲机） 电场强度： 直接测量法 频率范围 范围 频率范围 范围 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-04 wydanie 2 z dnia 31.07.2026 r.","technique_zh":"直接测量法","test_object_zh":"工作环境 － 无线电通信与防盗系统产生的电磁场：－ 手持对讲机、终端与短距离无线设备、随身与车载电台（对讲机）"},{"_id":"6a82d0a1884ede9a1b2c30e2","lab_id":"69ad52a3de79e566650fb676","country":"PL","accr_number":"AB 1263","accr_body":"PCA","test_object":"Środowisko pracy − pole elektromagnetyczne pochodzące od systemów radiokomunikacyjnych i antykradzieżowych: - radiotelefony doręczne, terminale i urządzenia bezprzewodowe krótkiego zasięgu, radiostacje (radiotelefony) nasobne i przewoźne","methodology":"Indukcja magnetyczna:","parameters":[{"name":"w zakresie częstotliwości","range":"0 Hz"},{"name":"Zakres","range":"200 µT – 1200 mT"},{"name":"w zakresie częstotliwości","range":"od 5 Hz do 400 kHz"},{"name":"Zakres","range":"0,02 µT – 12 mT"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości 0 Hz\nZakres 200 µT – 1200 mT\nw zakresie częstotliwości od 5 Hz do 400 kHz\nZakres 0,02 µT – 12 mT\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-04 wydanie 2 z dnia 31.07.2026 r.","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","Instrukcja IB-02_Z-04 wydanie 2 z dnia 31.07.2026 r."],"lab_section":"Laboratorium Badań Czynników Fizycznych LAB-TOP","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − pole elektromagnetyczne pochodzące od systemów radiokomunikacyjnych i antykradzieżowych: - radiotelefony doręczne, terminale i urządzenia bezprzewodowe krótkiego zasięgu, radiostacje (radiotelefony) nasobne i przewoźne Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości 0 Hz\nZakres 200 µT – 1200 mT\nw zakresie częstotliwości od 5 Hz do 400 kHz\nZakres 0,02 µT – 12 mT\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-04 wydanie 2 z dnia 31.07.2026 r. Srodowisko pracy − pole elektromagnetyczne pochodzace od systemow radiokomunikacyjnych i antykradziezowych: - radiotelefony doreczne, terminale i urzadzenia bezprzewodowe krotkiego zasiegu, radiostacje (radiotelefony) nasobne i przewozne Indukcja magnetyczna:\nZakres:\nw zakresie czestotliwosci 0 Hz\nZakres 200 µT – 1200 mT\nw zakresie czestotliwosci od 5 Hz do 400 kHz\nZakres 0,02 µT – 12 mT\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-04 wydanie 2 z dnia 31.07.2026 r.","categories":["environment"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic flux density:","parameters_en":[{"name":"in the frequency range","range":"0 Hz"},{"name":"Range","range":"200 µT – 1200 mT"},{"name":"in the frequency range","range":"od 5 Hz do 400 kHz"},{"name":"Range","range":"0,02 µT – 12 mT"}],"search_en":"Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: - handheld radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) Magnetic flux density: Direct measurement method in the frequency range Range in the frequency range Range PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-04 wydanie 2 z dnia 31.07.2026 r.","technique_en":"Direct measurement method","test_object_en":"Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: - handheld radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones)","parameters_zh":[{"name":"频率范围","range":"0 Hz"},{"name":"范围","range":"200 µT – 1200 mT"},{"name":"频率范围","range":"od 5 Hz do 400 kHz"},{"name":"范围","range":"0,02 µT – 12 mT"}],"search_zh":"工作环境 － 无线电通信与防盗系统产生的电磁场：－ 手持对讲机、终端与短距离无线设备、随身与车载电台（对讲机） 磁感应强度： 直接测量法 频率范围 范围 频率范围 范围 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-04 wydanie 2 z dnia 31.07.2026 r.","technique_zh":"直接测量法","methodology_zh":"磁感应强度：","test_object_zh":"工作环境 － 无线电通信与防盗系统产生的电磁场：－ 手持对讲机、终端与短距离无线设备、随身与车载电台（对讲机）"},{"_id":"6a82d0a1884ede9a1b2c30e3","lab_id":"69ad52a3de79e566650fb676","country":"PL","accr_number":"AB 1263","accr_body":"PCA","test_object":"Środowisko pracy − pole elektromagnetyczne pochodzące od systemów radiokomunikacyjnych i antykradzieżowych: - radiotelefony doręczne, terminale i urządzenia bezprzewodowe krótkiego zasięgu, radiostacje (radiotelefony) nasobne i przewoźne","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości","range":"od 20 Hz do 20 kHz"},{"name":"Zakres","range":"1,6 A/m – 7 kA/m"},{"name":"w zakresie częstotliwości","range":"od 0,3 MHz do 30 MHz"},{"name":"Zakres","range":"(0,0105 – 16) A/m"},{"name":"w zakresie częstotliwości","range":"od 0,026 GHz do 1,0 GHz"},{"name":"Zakres","range":"(0,013 – 4,2) A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 20 Hz do 20 kHz\nZakres 1,6 A/m – 7 kA/m\nw zakresie częstotliwości od 0,3 MHz do 30 MHz\nZakres (0,0105 – 16) A/m\nw zakresie częstotliwości od 0,026 GHz do 1,0 GHz\nZakres (0,013 – 4,2) A/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-04 wydanie 2 z dnia 31.07.2026 r.","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","Instrukcja IB-02_Z-04 wydanie 2 z dnia 31.07.2026 r."],"lab_section":"Laboratorium Badań Czynników Fizycznych LAB-TOP","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − pole elektromagnetyczne pochodzące od systemów radiokomunikacyjnych i antykradzieżowych: - radiotelefony doręczne, terminale i urządzenia bezprzewodowe krótkiego zasięgu, radiostacje (radiotelefony) nasobne i przewoźne Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 20 Hz do 20 kHz\nZakres 1,6 A/m – 7 kA/m\nw zakresie częstotliwości od 0,3 MHz do 30 MHz\nZakres (0,0105 – 16) A/m\nw zakresie częstotliwości od 0,026 GHz do 1,0 GHz\nZakres (0,013 – 4,2) A/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-04 wydanie 2 z dnia 31.07.2026 r. Srodowisko pracy − pole elektromagnetyczne pochodzace od systemow radiokomunikacyjnych i antykradziezowych: - radiotelefony doreczne, terminale i urzadzenia bezprzewodowe krotkiego zasiegu, radiostacje (radiotelefony) nasobne i przewozne Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 20 Hz do 20 kHz\nZakres 1,6 A/m – 7 kA/m\nw zakresie czestotliwosci od 0,3 MHz do 30 MHz\nZakres (0,0105 – 16) A/m\nw zakresie czestotliwosci od 0,026 GHz do 1,0 GHz\nZakres (0,013 – 4,2) A/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-04 wydanie 2 z dnia 31.07.2026 r.","categories":["environment"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"in the frequency range","range":"od 20 Hz do 20 kHz"},{"name":"Range","range":"1,6 A/m – 7 kA/m"},{"name":"in the frequency range","range":"od 0,3 MHz do 30 MHz"},{"name":"Range","range":"(0,0105 – 16) A/m"},{"name":"in the frequency range","range":"od 0,026 GHz do 1,0 GHz"},{"name":"Range","range":"(0,013 – 4,2) A/m"}],"search_en":"Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: - handheld radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) Magnetic field strength: Direct measurement method in the frequency range Range in the frequency range Range in the frequency range Range PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-04 wydanie 2 z dnia 31.07.2026 r.","technique_en":"Direct measurement method","test_object_en":"Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: - handheld radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones)","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围","range":"od 20 Hz do 20 kHz"},{"name":"范围","range":"1,6 A/m – 7 kA/m"},{"name":"频率范围","range":"od 0,3 MHz do 30 MHz"},{"name":"范围","range":"(0,0105 – 16) A/m"},{"name":"频率范围","range":"od 0,026 GHz do 1,0 GHz"},{"name":"范围","range":"(0,013 – 4,2) A/m"}],"search_zh":"工作环境 － 无线电通信与防盗系统产生的电磁场：－ 手持对讲机、终端与短距离无线设备、随身与车载电台（对讲机） 磁场强度： 直接测量法 频率范围 范围 频率范围 范围 频率范围 范围 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-04 wydanie 2 z dnia 31.07.2026 r.","technique_zh":"直接测量法","test_object_zh":"工作环境 － 无线电通信与防盗系统产生的电磁场：－ 手持对讲机、终端与短距离无线设备、随身与车载电台（对讲机）"},{"_id":"6a82d0a1884ede9a1b2c30e4","lab_id":"69ad52a3de79e566650fb676","country":"PL","accr_number":"AB 1263","accr_body":"PCA","test_object":"Środowisko pracy − pole elektromagnetyczne pochodzące od systemów radiokomunikacyjnych i antykradzieżowych: - radiotelefony doręczne, terminale i urządzenia bezprzewodowe krótkiego zasięgu, radiostacje (radiotelefony) nasobne i przewoźne","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości","range":"0 Hz"},{"name":"w zakresie częstotliwości","range":"od 5 Hz do 400 kHz"},{"name":"w zakresie częstotliwości","range":"od 1 GHz do 18 GHz"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości 0 Hz\nw zakresie częstotliwości od 5 Hz do 400 kHz\nw zakresie częstotliwości od 1 GHz do 18 GHz\n(z obliczeń)","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-04 wydanie 2 z dnia 31.07.2026 r.","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","Instrukcja IB-02_Z-04 wydanie 2 z dnia 31.07.2026 r."],"lab_section":"Laboratorium Badań Czynników Fizycznych LAB-TOP","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − pole elektromagnetyczne pochodzące od systemów radiokomunikacyjnych i antykradzieżowych: - radiotelefony doręczne, terminale i urządzenia bezprzewodowe krótkiego zasięgu, radiostacje (radiotelefony) nasobne i przewoźne Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości 0 Hz\nw zakresie częstotliwości od 5 Hz do 400 kHz\nw zakresie częstotliwości od 1 GHz do 18 GHz\n(z obliczeń) PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-04 wydanie 2 z dnia 31.07.2026 r. Srodowisko pracy − pole elektromagnetyczne pochodzace od systemow radiokomunikacyjnych i antykradziezowych: - radiotelefony doreczne, terminale i urzadzenia bezprzewodowe krotkiego zasiegu, radiostacje (radiotelefony) nasobne i przewozne Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci 0 Hz\nw zakresie czestotliwosci od 5 Hz do 400 kHz\nw zakresie czestotliwosci od 1 GHz do 18 GHz\n(z obliczen) PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-04 wydanie 2 z dnia 31.07.2026 r.","categories":["environment"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"in the frequency range","range":"0 Hz"},{"name":"in the frequency range","range":"od 5 Hz do 400 kHz"},{"name":"in the frequency range","range":"od 1 GHz do 18 GHz"},{"name":"(calculated)"}],"search_en":"Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: - handheld radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) Magnetic field strength: in the frequency range in the frequency range in the frequency range (calculated) PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-04 wydanie 2 z dnia 31.07.2026 r.","test_object_en":"Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: - handheld radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones)","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围","range":"0 Hz"},{"name":"频率范围","range":"od 5 Hz do 400 kHz"},{"name":"频率范围","range":"od 1 GHz do 18 GHz"},{"name":"（计算得出）"}],"search_zh":"工作环境 － 无线电通信与防盗系统产生的电磁场：－ 手持对讲机、终端与短距离无线设备、随身与车载电台（对讲机） 磁场强度： 频率范围 频率范围 频率范围 （计算得出） PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-04 wydanie 2 z dnia 31.07.2026 r.","test_object_zh":"工作环境 － 无线电通信与防盗系统产生的电磁场：－ 手持对讲机、终端与短距离无线设备、随身与车载电台（对讲机）"},{"_id":"6a82d0a1884ede9a1b2c30e5","lab_id":"69ad52a3de79e566650fb676","country":"PL","accr_number":"AB 1263","accr_body":"PCA","test_object":"Środowisko pracy − pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne - skanery rezonansu magnetycznego","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"w zakresie częstotliwości","range":"od 5 Hz do 400 kHz"},{"name":"Zakres","range":"1 V/m – 50 kV/m"},{"name":"w zakresie częstotliwości","range":"od 100 kHz do 18 GHz"},{"name":"Zakres","range":"(0,5 – 900) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 5 Hz do 400 kHz\nZakres 1 V/m – 50 kV/m\nw zakresie częstotliwości od 100 kHz do 18 GHz\nZakres (0,5 – 900) V/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-02 wydanie 5 z dnia 31.07.2026 r.","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","Instrukcja IB-02_Z-02 wydanie 5 z dnia 31.07.2026 r."],"lab_section":"Laboratorium Badań Czynników Fizycznych LAB-TOP","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne - skanery rezonansu magnetycznego Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 5 Hz do 400 kHz\nZakres 1 V/m – 50 kV/m\nw zakresie częstotliwości od 100 kHz do 18 GHz\nZakres (0,5 – 900) V/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-02 wydanie 5 z dnia 31.07.2026 r. Srodowisko pracy − pole elektromagnetyczne pochodzace od urzadzen stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne - skanery rezonansu magnetycznego Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 5 Hz do 400 kHz\nZakres 1 V/m – 50 kV/m\nw zakresie czestotliwosci od 100 kHz do 18 GHz\nZakres (0,5 – 900) V/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-02 wydanie 5 z dnia 31.07.2026 r.","categories":["environment"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength:","parameters_en":[{"name":"in the frequency range","range":"od 5 Hz do 400 kHz"},{"name":"Range","range":"1 V/m – 50 kV/m"},{"name":"in the frequency range","range":"od 100 kHz do 18 GHz"},{"name":"Range","range":"(0,5 – 900) V/m"}],"search_en":"Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units - magnetic resonance scanners Electric field strength: Direct measurement method in the frequency range Range in the frequency range Range PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-02 wydanie 5 z dnia 31.07.2026 r.","technique_en":"Direct measurement method","test_object_en":"Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units - magnetic resonance scanners","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围","range":"od 5 Hz do 400 kHz"},{"name":"范围","range":"1 V/m – 50 kV/m"},{"name":"频率范围","range":"od 100 kHz do 18 GHz"},{"name":"范围","range":"(0,5 – 900) V/m"}],"search_zh":"工作环境 － 医疗技术设备产生的电磁场：－ 外科电刀 － 理疗透热治疗仪 － 磁共振扫描仪 电场强度： 直接测量法 频率范围 范围 频率范围 范围 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-02 wydanie 5 z dnia 31.07.2026 r.","technique_zh":"直接测量法","test_object_zh":"工作环境 － 医疗技术设备产生的电磁场：－ 外科电刀 － 理疗透热治疗仪 － 磁共振扫描仪"},{"_id":"6a82d0a1884ede9a1b2c30e6","lab_id":"69ad52a3de79e566650fb676","country":"PL","accr_number":"AB 1263","accr_body":"PCA","test_object":"Środowisko pracy − pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne - skanery rezonansu magnetycznego","methodology":"Indukcja magnetyczna:","parameters":[{"name":"w zakresie częstotliwości","range":"0 Hz"},{"name":"Zakres","range":"200 µT – 1200 mT"},{"name":"w zakresie częstotliwości","range":"od 5 Hz do 400 kHz"},{"name":"Zakres","range":"0,02 µT – 12 mT"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości 0 Hz\nZakres 200 µT – 1200 mT\nw zakresie częstotliwości od 5 Hz do 400 kHz\nZakres 0,02 µT – 12 mT\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-02 wydanie 5 z dnia 31.07.2026 r.","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","Instrukcja IB-02_Z-02 wydanie 5 z dnia 31.07.2026 r."],"lab_section":"Laboratorium Badań Czynników Fizycznych LAB-TOP","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne - skanery rezonansu magnetycznego Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości 0 Hz\nZakres 200 µT – 1200 mT\nw zakresie częstotliwości od 5 Hz do 400 kHz\nZakres 0,02 µT – 12 mT\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-02 wydanie 5 z dnia 31.07.2026 r. Srodowisko pracy − pole elektromagnetyczne pochodzace od urzadzen stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne - skanery rezonansu magnetycznego Indukcja magnetyczna:\nZakres:\nw zakresie czestotliwosci 0 Hz\nZakres 200 µT – 1200 mT\nw zakresie czestotliwosci od 5 Hz do 400 kHz\nZakres 0,02 µT – 12 mT\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-02 wydanie 5 z dnia 31.07.2026 r.","categories":["environment"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic flux density:","parameters_en":[{"name":"in the frequency range","range":"0 Hz"},{"name":"Range","range":"200 µT – 1200 mT"},{"name":"in the frequency range","range":"od 5 Hz do 400 kHz"},{"name":"Range","range":"0,02 µT – 12 mT"}],"search_en":"Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units - magnetic resonance scanners Magnetic flux density: Direct measurement method in the frequency range Range in the frequency range Range PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-02 wydanie 5 z dnia 31.07.2026 r.","technique_en":"Direct measurement method","test_object_en":"Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units - magnetic resonance scanners","parameters_zh":[{"name":"频率范围","range":"0 Hz"},{"name":"范围","range":"200 µT – 1200 mT"},{"name":"频率范围","range":"od 5 Hz do 400 kHz"},{"name":"范围","range":"0,02 µT – 12 mT"}],"search_zh":"工作环境 － 医疗技术设备产生的电磁场：－ 外科电刀 － 理疗透热治疗仪 － 磁共振扫描仪 磁感应强度： 直接测量法 频率范围 范围 频率范围 范围 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-02 wydanie 5 z dnia 31.07.2026 r.","technique_zh":"直接测量法","methodology_zh":"磁感应强度：","test_object_zh":"工作环境 － 医疗技术设备产生的电磁场：－ 外科电刀 － 理疗透热治疗仪 － 磁共振扫描仪"},{"_id":"6a82d0a1884ede9a1b2c30e7","lab_id":"69ad52a3de79e566650fb676","country":"PL","accr_number":"AB 1263","accr_body":"PCA","test_object":"Środowisko pracy − pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne - skanery rezonansu magnetycznego","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości","range":"od 20 Hz do 20 kHz"},{"name":"Zakres","range":"1,6 A/m – 7 kA/m"},{"name":"w zakresie częstotliwości","range":"od 0,3 MHz do 30 MHz"},{"name":"Zakres","range":"(0,0105 – 16) A/m"},{"name":"w zakresie częstotliwości","range":"od 0,026 GHz do 1,0 GHz"},{"name":"Zakres","range":"(0,013 – 4,2) A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 20 Hz do 20 kHz\nZakres 1,6 A/m – 7 kA/m\nw zakresie częstotliwości od 0,3 MHz do 30 MHz\nZakres (0,0105 – 16) A/m\nw zakresie częstotliwości od 0,026 GHz do 1,0 GHz\nZakres (0,013 – 4,2) A/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-02 wydanie 5 z dnia 31.07.2026 r.","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","Instrukcja IB-02_Z-02 wydanie 5 z dnia 31.07.2026 r."],"lab_section":"Laboratorium Badań Czynników Fizycznych LAB-TOP","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne - skanery rezonansu magnetycznego Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 20 Hz do 20 kHz\nZakres 1,6 A/m – 7 kA/m\nw zakresie częstotliwości od 0,3 MHz do 30 MHz\nZakres (0,0105 – 16) A/m\nw zakresie częstotliwości od 0,026 GHz do 1,0 GHz\nZakres (0,013 – 4,2) A/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-02 wydanie 5 z dnia 31.07.2026 r. Srodowisko pracy − pole elektromagnetyczne pochodzace od urzadzen stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne - skanery rezonansu magnetycznego Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 20 Hz do 20 kHz\nZakres 1,6 A/m – 7 kA/m\nw zakresie czestotliwosci od 0,3 MHz do 30 MHz\nZakres (0,0105 – 16) A/m\nw zakresie czestotliwosci od 0,026 GHz do 1,0 GHz\nZakres (0,013 – 4,2) A/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-02 wydanie 5 z dnia 31.07.2026 r.","categories":["environment"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"in the frequency range","range":"od 20 Hz do 20 kHz"},{"name":"Range","range":"1,6 A/m – 7 kA/m"},{"name":"in the frequency range","range":"od 0,3 MHz do 30 MHz"},{"name":"Range","range":"(0,0105 – 16) A/m"},{"name":"in the frequency range","range":"od 0,026 GHz do 1,0 GHz"},{"name":"Range","range":"(0,013 – 4,2) A/m"}],"search_en":"Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units - magnetic resonance scanners Magnetic field strength: Direct measurement method in the frequency range Range in the frequency range Range in the frequency range Range PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-02 wydanie 5 z dnia 31.07.2026 r.","technique_en":"Direct measurement method","test_object_en":"Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units - magnetic resonance scanners","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围","range":"od 20 Hz do 20 kHz"},{"name":"范围","range":"1,6 A/m – 7 kA/m"},{"name":"频率范围","range":"od 0,3 MHz do 30 MHz"},{"name":"范围","range":"(0,0105 – 16) A/m"},{"name":"频率范围","range":"od 0,026 GHz do 1,0 GHz"},{"name":"范围","range":"(0,013 – 4,2) A/m"}],"search_zh":"工作环境 － 医疗技术设备产生的电磁场：－ 外科电刀 － 理疗透热治疗仪 － 磁共振扫描仪 磁场强度： 直接测量法 频率范围 范围 频率范围 范围 频率范围 范围 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-02 wydanie 5 z dnia 31.07.2026 r.","technique_zh":"直接测量法","test_object_zh":"工作环境 － 医疗技术设备产生的电磁场：－ 外科电刀 － 理疗透热治疗仪 － 磁共振扫描仪"},{"_id":"6a82d0a1884ede9a1b2c30e8","lab_id":"69ad52a3de79e566650fb676","country":"PL","accr_number":"AB 1263","accr_body":"PCA","test_object":"Środowisko pracy − pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne - skanery rezonansu magnetycznego","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości","range":"0 Hz"},{"name":"w zakresie częstotliwości","range":"od 5 Hz do 400 kHz"},{"name":"w zakresie częstotliwości","range":"od 1 GHz do 18 GHz"},{"name":"(z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości 0 Hz\nw zakresie częstotliwości od 5 Hz do 400 kHz\nw zakresie częstotliwości od 1 GHz do 18 GHz\n(z obliczeń)","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-02 wydanie 5 z dnia 31.07.2026 r.","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","Instrukcja IB-02_Z-02 wydanie 5 z dnia 31.07.2026 r."],"lab_section":"Laboratorium Badań Czynników Fizycznych LAB-TOP","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne - skanery rezonansu magnetycznego Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości 0 Hz\nw zakresie częstotliwości od 5 Hz do 400 kHz\nw zakresie częstotliwości od 1 GHz do 18 GHz\n(z obliczeń) PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-02 wydanie 5 z dnia 31.07.2026 r. Srodowisko pracy − pole elektromagnetyczne pochodzace od urzadzen stosowanych w technice medycznej: - diatermie chirurgiczne - diatermie fizykoterapeutyczne - skanery rezonansu magnetycznego Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci 0 Hz\nw zakresie czestotliwosci od 5 Hz do 400 kHz\nw zakresie czestotliwosci od 1 GHz do 18 GHz\n(z obliczen) PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-02 wydanie 5 z dnia 31.07.2026 r.","categories":["environment"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"in the frequency range","range":"0 Hz"},{"name":"in the frequency range","range":"od 5 Hz do 400 kHz"},{"name":"in the frequency range","range":"od 1 GHz do 18 GHz"},{"name":"(calculated)"}],"search_en":"Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units - magnetic resonance scanners Magnetic field strength: in the frequency range in the frequency range in the frequency range (calculated) PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-02 wydanie 5 z dnia 31.07.2026 r.","test_object_en":"Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units - magnetic resonance scanners","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围","range":"0 Hz"},{"name":"频率范围","range":"od 5 Hz do 400 kHz"},{"name":"频率范围","range":"od 1 GHz do 18 GHz"},{"name":"（计算得出）"}],"search_zh":"工作环境 － 医疗技术设备产生的电磁场：－ 外科电刀 － 理疗透热治疗仪 － 磁共振扫描仪 磁场强度： 频率范围 频率范围 频率范围 （计算得出） PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | Instrukcja IB-02_Z-02 wydanie 5 z dnia 31.07.2026 r.","test_object_zh":"工作环境 － 医疗技术设备产生的电磁场：－ 外科电刀 － 理疗透热治疗仪 － 磁共振扫描仪"},{"_id":"6a82d0a1884ede9a1b2c30e9","lab_id":"69ad52a3de79e566650fb676","country":"PL","accr_number":"AB 1263","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne (elektromagnetyczne linie napowietrzne bez ograniczenia napięcia)","methodology":"Natężenie pola elektrycznego","parameters":[{"name":"o częstotliwości","range":"50 Hz"}],"technique":"Metoda obliczeniowa","techniques":["Metoda obliczeniowa"],"computed":[],"activity":"Natężenie pola elektrycznego\no częstotliwości 50 Hz\nMetoda obliczeniowa","reference":"Procedura badawcza PB-02 wydanie 3 z dnia 31.07.2026 r.","norm_bases":["Procedura badawcza PB-02 wydanie 3 z dnia 31.07.2026 r."],"lab_section":"Laboratorium Badań Czynników Fizycznych LAB-TOP","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko – pole elektromagnetyczne (elektromagnetyczne linie napowietrzne bez ograniczenia napięcia) Natężenie pola elektrycznego\no częstotliwości 50 Hz\nMetoda obliczeniowa Procedura badawcza PB-02 wydanie 3 z dnia 31.07.2026 r. Srodowisko – pole elektromagnetyczne (elektromagnetyczne linie napowietrzne bez ograniczenia napiecia) Natezenie pola elektrycznego\no czestotliwosci 50 Hz\nMetoda obliczeniowa Procedura badawcza PB-02 wydanie 3 z dnia 31.07.2026 r.","categories":["environment"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength","search_en":"Environment – electromagnetic field (electromagnetic overhead lines without voltage limitation) Electric field strength Calculation method Procedura badawcza PB-02 wydanie 3 z dnia 31.07.2026 r.","technique_en":"Calculation method","test_object_en":"Environment – electromagnetic field (electromagnetic overhead lines without voltage limitation)","search_zh":"电场强度 计算法 Procedura badawcza PB-02 wydanie 3 z dnia 31.07.2026 r.","technique_zh":"计算法","methodology_zh":"电场强度"},{"_id":"6a82d0a1884ede9a1b2c30ea","lab_id":"69ad52a3de79e566650fb676","country":"PL","accr_number":"AB 1263","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne (elektromagnetyczne linie napowietrzne bez ograniczenia napięcia)","methodology":"Natężenie pola magnetycznego","parameters":[{"name":"o częstotliwości","range":"50 Hz"}],"technique":"Metoda obliczeniowa","techniques":["Metoda obliczeniowa"],"computed":[],"activity":"Natężenie pola magnetycznego\no częstotliwości 50 Hz\nMetoda obliczeniowa","reference":"Procedura badawcza PB-02 wydanie 3 z dnia 31.07.2026 r.","norm_bases":["Procedura badawcza PB-02 wydanie 3 z dnia 31.07.2026 r."],"lab_section":"Laboratorium Badań Czynników Fizycznych LAB-TOP","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko – pole elektromagnetyczne (elektromagnetyczne linie napowietrzne bez ograniczenia napięcia) Natężenie pola magnetycznego\no częstotliwości 50 Hz\nMetoda obliczeniowa Procedura badawcza PB-02 wydanie 3 z dnia 31.07.2026 r. Srodowisko – pole elektromagnetyczne (elektromagnetyczne linie napowietrzne bez ograniczenia napiecia) Natezenie pola magnetycznego\no czestotliwosci 50 Hz\nMetoda obliczeniowa Procedura badawcza PB-02 wydanie 3 z dnia 31.07.2026 r.","categories":["environment"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength","search_en":"Environment – electromagnetic field (electromagnetic overhead lines without voltage limitation) Magnetic field strength Calculation method Procedura badawcza PB-02 wydanie 3 z dnia 31.07.2026 r.","technique_en":"Calculation method","test_object_en":"Environment – electromagnetic field (electromagnetic overhead lines without voltage limitation)","search_zh":"磁场强度 计算法 Procedura badawcza PB-02 wydanie 3 z dnia 31.07.2026 r.","technique_zh":"计算法","methodology_zh":"磁场强度"}],"has_pdf":true}