🇵🇱 Grupa Azoty Zakłady Fosforowe Gdańsk Sp. z o.o. PL
EnvironmentWater & wastewaterConstruction
Grupa Azoty Zakłady Fosforowe Gdańsk Sp. z o.o. is a laboratory accredited by PCA under number AB 1261 (Gdańsk, Poland). Its accreditation scope covers 29 test methods in the following areas: Environment, Water & wastewater, Construction. Test objects include: Workplace environment - air, Workplace environment - air samples collected on filters, Workplace environment - air samples collected into absorbing solution, General environment - noise from installations, equipment and indus…. Most frequently used techniques: Spectrophotometric method, Potentiometric method, Flame atomic absorption spectrometry (FAAS).
At a glance
- Accreditation number: PCA AB 1261
- Methods in scope: 29
- Types of test objects: 8
- Techniques used: 9
- City: Gdańsk, Poland
- Accreditation number
- AB 1261
- Accreditation body
- PCA
- Address
- LABORATORIUM OCHRONY ŚRODOWISKA, ul. Kujawska 2, 80-550 Gdańsk
- City
- Gdańsk, Poland
What this laboratory tests (8)
- Workplace environment - air — 13 methods
- Workplace environment - air samples collected on filters — 5 methods
- Workplace environment - air samples collected into absorbing solution — 3 methods
- General environment - noise from installations, equipment and industrial plants — 2 methods
- Water, wastewater, Rainwater and snowmelt water — 2 methods
- Workplace environment – noise — 2 methods
- Wastewater, Rainwater and snowmelt water — 1 method
- Water — 1 method
Analytical techniques used (9)
- Spectrophotometric method — 6 methods
- Potentiometric method — 5 methods
- Flame atomic absorption spectrometry (FAAS) — 4 methods
- Gravimetric method — 3 methods
- Direct measurement method — 2 methods
- Manual method — 2 methods
- Turbidimetric method — 2 methods
- Personal dosimetry method — 1 method
- Personal dosimetry method; Stationary method — 1 method
Laboratory locations
- LABORATORIUM OCHRONY ŚRODOWISKA — ul. Kujawska 2
Accreditation scope — test methods (29)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Environmental Protection Laboratory | |||||
| 1 | Workplace environment - air | Sampling for the assessment of occupational exposure to: industrial dusts: inhalable fraction, respirable fraction, metals and their compounds, including: inhalable fraction, respirable fraction, |
Personal dosimetry method | PN-Z-04008-7:2002+ Az1:2004 | |
| 2 | Workplace environment - air | Sampling for the assessment of occupational exposure to: inorganic substances, including inhalable fraction, thoracic fraction respirable fraction |
Personal dosimetry method; Stationary method | PN-Z-04008-7:2002+ Az1:2004 | |
| 3 | Workplace environment - air | Exposure index (calculated) | PN-Z-04008-7:2002+ Az1:2004 | ||
| 4 | Workplace environment - air | Concentration of harmful dust agents – inhalable fraction: Apatites and phosphorites Portland cement Titanium dioxide Synthetic graphite Kaolin Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Carbon black Calcium sulfate (VI) (gypsum) Coal (hard, brown) Magnesium, calcium carbonate (dolomite) Silicon carbide, non-fibrous Range (0,20 - 81,67) mg/m3 |
Gravimetric method | PN-Z-04507:2022-05+Ap1:2022-08 | |
| 5 | Workplace environment - air | Concentration of harmful dust agents – respirable fraction: Apatites and phosphorites Portland cement Organic dusts of animal and plant origin, excluding wood and flour dusts Coal (hard, brown) Range (0,20 - 87,72) mg/m3 |
Gravimetric method | PN-Z-04508:2022-05+Ap1:2022-08 | |
| 6 | Workplace environment - air | Fluoride concentration calculated as F - Range (0,028- 4,166) mg/m3 |
Potentiometric method | NIOSH method 7902 Issue 2, date 15 August 1994 | |
| 7 | Workplace environment - air | Hydrogen fluoride concentration Range (0,015 – 4,387) mg/m3 |
Potentiometric method | NIOSH method 7902 Issue 2, date 15 August 1994 | |
| 8 | Workplace environment - air | Ammonia concentration Range (0,75 - 50,00) mg/m3 |
Spectrophotometric method | PN-71/Z-04041 | |
| 9 | Workplace environment - air | Hydrogen chloride concentration Range (0,50 - 50,00) mg/m3 |
Turbidimetric method | PN-Z-04450:2014-08 | |
| 10 | Workplace environment - air | Sulphur dioxide concentration Range (0,16 - 6,40) mg/m3 |
Spectrophotometric method | PN-Z-04015-12:1996+Ap1:2001 | |
| 11 | Workplace environment - air | Concentration of manganese and its inorganic compounds calculated as Mn inhalable fraction Range (0,02 - 0,40) mg/m3 respirable fraction Range (0,005 - 0,100) mg/m3 |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04472:2015-10+Ap1:2015-12 | |
| 12 | Workplace environment - air | Concentration of iron oxides calculated as Fe inhalable fraction Range (0,50 – 20,00) mg/m3 respirable fraction Range (0,25 - 10,00) mg/m3 |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04469:2025-02 | |
| 13 | Workplace environment - air | Phosphoric (V) acid concentration Range (0,10 - 10,32) mg/m3 |
Spectrophotometric method | PN-Z-04073-1:2014-08 | |
| 14 | Workplace environment - air samples collected on filters | Fluoride content calculated as F - Range (0,020-0,300) mg w próbce |
Potentiometric method | NIOSH method 7902 Issue 2, date 15 August 1994 | |
| 15 | Workplace environment - air samples collected on filters | Content of manganese and its inorganic compounds calculated as Mn inhalable fraction Range (0,012 - 0,240) mg w próbce respirable fraction Range (0,003 - 0,060) mg w próbce |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04472:2015-10+Ap1:2015-12 | |
| 16 | Workplace environment - air samples collected on filters | Content of iron oxides expressed as Fe - inhalable fraction Range (0,36 - 14,40) mg w próbce respirable fraction Range (0,18 - 7,20) mg w próbce |
Flame atomic absorption spectrometry (FAAS) | PN-Z-04469:2025-02 | |
| 17 | Workplace environment - air samples collected on filters | Hydrogen chloride content Range (0,20 - 20,00) mg w próbce |
Turbidimetric method | PN-Z-04450:2014-08 | |
| 18 | Workplace environment - air samples collected on filters | Hydrogen fluoride content Range (0,011 – 0,315) mg w próbce |
Potentiometric method | NIOSH method 7902 Issue 2, date 15 August 1994 | |
| 19 | Workplace environment - air samples collected into absorbing solution | Ammonia content Range (0,045 - 3,000) mg w próbce |
Spectrophotometric method | PN-71/Z-04041 | |
| 20 | Workplace environment - air samples collected into absorbing solution | Sulfur dioxide content Range (0,0016 - 0,0640) mg w sample |
Spectrophotometric method | PN-Z-04015-12:1996+Ap1:2001 | |
| 21 | Workplace environment - air samples collected into absorbing solution | Phosphoric (V) acid content Range (0,00206 - 0,10316) mg w sample |
Spectrophotometric method | PN-Z-04073-1:2014-08 | |
| 22 | Workplace environment – noise | A-weighted equivalent sound level Maximum A-weighted sound level Range (25,0 - 137,0) dB C-weighted peak sound pressure level Range (25,0 - 137) dB |
Direct measurement method | PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i 3 - punkt 10 i 11 | |
| 23 | Workplace environment – noise | Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated) |
PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i 3 - punkt 10 i 11 | ||
| 24 | General environment - noise from installations, equipment and industrial plants | A-weighted equivalent sound pressure level Range (25,0 - 137,0) dB |
Direct measurement method | Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j.Dz.U.2023 poz.1706) z wyłączeniem punktu F | |
| 25 | General environment - noise from installations, equipment and industrial plants | A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) | Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j.Dz.U.2023 poz.1706) z wyłączeniem punktu F | ||
| 26 | Water | Sampling for physical testing Temperature Range (0,5 - 40,0) 0C |
Manual method | PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2; 7.3; 7.5; 7.6 P N-77/C-04584 | |
| 27 | Wastewater, Rainwater and snowmelt water | Sampling for physical testing Temperature Range (0,5 - 40,0) 0C |
Manual method | PN-ISO 5667-10:2021-11 | PN-77/C-04584 | |
| 28 | Water, wastewater, Rainwater and snowmelt water | pH Range 2,0 - 10,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 29 | Water, wastewater, Rainwater and snowmelt water | Total suspended solids (TSS) Range (2,0 - 1000) mg/l |
Gravimetric method | PN-EN 872:2007 + Ap1:2007 | |
Reference standards (18)
NIOSH method 7902 Issue 2, date 15 August 1994
PN-71/Z-04041
PN-77/C-04584
PN-EN 872:2007 + Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2; 7.3; 7.5; 7.6 P N-77/C-04584
PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i 3 - punkt 10 i 11
PN-ISO 5667-10:2021-11
PN-N-01307:1994
PN-Z-04008-7:2002+ Az1:2004
PN-Z-04015-12:1996+Ap1:2001
PN-Z-04073-1:2014-08
PN-Z-04450:2014-08
PN-Z-04469:2025-02
PN-Z-04472:2015-10+Ap1:2015-12
PN-Z-04507:2022-05+Ap1:2022-08
PN-Z-04508:2022-05+Ap1:2022-08
Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j.Dz.U.2023 poz.1706) z wyłączeniem punktu F