{"lab":{"_id":"69ad52a3de79e566650fb674","accr_number":"AB 1261","country":"PL","accr_body":"PCA","address":"LABORATORIUM OCHRONY ŚRODOWISKA, ul. Kujawska 2, 80-550 Gdańsk","categories":["environment","water","construction"],"city":"Gdańsk","imported_at":"2026-03-08T10:42:43.265Z","methods_count":29,"name":"Grupa Azoty Zakłady Fosforowe Gdańsk Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1261.pdf"],"scope_summary":"","search_text":"grupa azoty zakłady fosforowe gdańsk sp. z o.o. laboratorium ochrony środowiska, ul. kujawska 2, 80-550 gdańsk environment materials construction electronics other automotive metrology water","status":"active","updated_at":"2026-03-08T14:50:26.038Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T07:58:54.265Z","email_confidence":"high","email_mx":true,"email_source":"https://www.fosfory.pl/kontakt/","parse_date":"2026-08-13T07:58:54.265Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"C/33/P","pl":"Badania chemiczne i pobieranie próbek – środowisko pracy (czynniki szkodliwe – powietrze)","en":"Chemical tests and sampling – working environment (harmful factors – air)"},{"codes":"G/33; G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) środowisko pracy (czynniki szkodliwe i uciążliwe – hałas), środowisko ogólne (czynniki fizyczne - hałas)","en":"Tests concerning environmental engineering (environmental and climatic) – working environment (harmful and nuisance factors – noise), general environment (physical factors - noise)"},{"codes":"N/28/P; N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody i ścieków","en":"Tests of physical properties and sampling of water and sewage"},{"codes":"N/33/P","pl":"Badania właściwości fizycznych i pobieranie próbek – środowisko pracy (czynniki szkodliwe – powietrze)","en":"Tests of physical properties and sampling – working environment (harmful factors – air)"},{"codes":"P/28; P/30; P/33","pl":"Pobieranie próbek powietrza, wody i ścieków","en":"Sampling of air, water and sewage"}],"issue":{"no":"21","date":"23.04.2026"},"map_coord":[54.377898,18.669012],"map_geo":"nominatim-street","lab_locations":[{"name":"LABORATORIUM OCHRONY ŚRODOWISKA","address":"ul. Kujawska 2","city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/fe0408142493c7c06991866b6a9b9c5c/AB%201261.pdf","has_en":true,"category_counts":{"environment":25,"water":4,"construction":2,"materials":1},"category_scores":{"environment":19.53,"water":0.5,"construction":0.13,"materials":0.03},"has_zh":true},"methods":[{"_id":"6a7d793e0636ba417e41a7e0","lab_id":"69ad52a3de79e566650fb674","country":"PL","accr_number":"AB 1261","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","parameters":[{"name":"pyły przemysłowe:"},{"name":"frakcja wdychalna,"},{"name":"frakcja respirabilna,"},{"name":"metale i ich związki, w tym:"},{"name":"frakcja wdychalna,"},{"name":"frakcja respirabilna,"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\npyły przemysłowe:\nfrakcja wdychalna,\nfrakcja respirabilna,\nmetale i ich związki, w tym:\nfrakcja wdychalna,\nfrakcja respirabilna,\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002+ Az1:2004","norm_bases":["PN-Z-04008-7:2002+ Az1:2004"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\npyły przemysłowe:\nfrakcja wdychalna,\nfrakcja respirabilna,\nmetale i ich związki, w tym:\nfrakcja wdychalna,\nfrakcja respirabilna,\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+ Az1:2004 Srodowisko pracy - powietrze Pobieranie probek do oceny narazenia zawodowego na:\nZakres:\npyly przemyslowe:\nfrakcja wdychalna,\nfrakcja respirabilna,\nmetale i ich zwiazki, w tym:\nfrakcja wdychalna,\nfrakcja respirabilna,\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+ Az1:2004","categories":["materials","environment"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"industrial dusts:"},{"name":"inhalable fraction,"},{"name":"respirable fraction,"},{"name":"metals and their compounds, including:"},{"name":"inhalable fraction,"},{"name":"respirable fraction,"}],"search_en":"Workplace environment - air Sampling for the assessment of occupational exposure to: Personal dosimetry method Environmental Protection Laboratory industrial dusts: inhalable fraction, respirable fraction, metals and their compounds, including: inhalable fraction, respirable fraction, PN-Z-04008-7:2002+ Az1:2004","technique_en":"Personal dosimetry method","test_object_en":"Workplace environment - air","methodology_zh":"职业接触评估采样，针对：","search_zh":"工作场所环境 — 空气 职业接触评估采样，针对： 个体剂量测定法 环境保护实验室 可吸入性粉尘， 呼吸性粉尘， 金属及其化合物，其中包括： 可吸入性粉尘， 呼吸性粉尘， PN-Z-04008-7:2002+ Az1:2004","technique_zh":"个体剂量测定法","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"环境保护实验室","parameters_zh":[{"name":"pyły przemysłowe:"},{"name":"可吸入性粉尘，"},{"name":"呼吸性粉尘，"},{"name":"金属及其化合物，其中包括："},{"name":"可吸入性粉尘，"},{"name":"呼吸性粉尘，"}]},{"_id":"6a7d793e0636ba417e41a7e1","lab_id":"69ad52a3de79e566650fb674","country":"PL","accr_number":"AB 1261","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","parameters":[{"name":"substancje nieorganiczne, w tym"},{"name":"frakcja wdychalna,"},{"name":"frakcja torakalna"},{"name":"frakcja respirabilna"}],"technique":"Metoda dozymetrii indywidualnej; Metoda stacjonarna","techniques":["Metoda dozymetrii indywidualnej","Metoda stacjonarna"],"computed":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nsubstancje nieorganiczne, w tym\nfrakcja wdychalna,\nfrakcja torakalna\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej; Metoda stacjonarna","reference":"PN-Z-04008-7:2002+ Az1:2004","norm_bases":["PN-Z-04008-7:2002+ Az1:2004"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nsubstancje nieorganiczne, w tym\nfrakcja wdychalna,\nfrakcja torakalna\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej; Metoda stacjonarna PN-Z-04008-7:2002+ Az1:2004 Srodowisko pracy - powietrze Pobieranie probek do oceny narazenia zawodowego na:\nZakres:\nsubstancje nieorganiczne, w tym\nfrakcja wdychalna,\nfrakcja torakalna\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej; Metoda stacjonarna PN-Z-04008-7:2002+ Az1:2004","categories":["environment"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"inorganic substances, including"},{"name":"inhalable fraction,"},{"name":"thoracic fraction"},{"name":"respirable fraction"}],"search_en":"Workplace environment - air Sampling for the assessment of occupational exposure to: Personal dosimetry method; Stationary method Environmental Protection Laboratory inorganic substances, including inhalable fraction, thoracic fraction respirable fraction PN-Z-04008-7:2002+ Az1:2004","technique_en":"Personal dosimetry method; Stationary method","test_object_en":"Workplace environment - air","methodology_zh":"职业接触评估采样，针对：","parameters_zh":[{"name":"无机物质，包括"},{"name":"可吸入性粉尘，"},{"name":"胸腔组分"},{"name":"呼吸性组分"}],"search_zh":"工作场所环境 — 空气 职业接触评估采样，针对： 个体剂量测定法；定点测定法 环境保护实验室 无机物质，包括 可吸入性粉尘， 胸腔组分 呼吸性组分 PN-Z-04008-7:2002+ Az1:2004","test_object_zh":"工作场所环境 — 空气","technique_zh":"个体剂量测定法；定点测定法","lab_section_zh":"环境保护实验室"},{"_id":"6a7d793e0636ba417e41a7e2","lab_id":"69ad52a3de79e566650fb674","country":"PL","accr_number":"AB 1261","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002+ Az1:2004","norm_bases":["PN-Z-04008-7:2002+ Az1:2004"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002+ Az1:2004 Srodowisko pracy - powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002+ Az1:2004","categories":["environment"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Exposure index (calculated)","search_en":"Workplace environment - air Exposure index (calculated) Environmental Protection Laboratory PN-Z-04008-7:2002+ Az1:2004","test_object_en":"Workplace environment - air","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出） 环境保护实验室 PN-Z-04008-7:2002+ Az1:2004","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"环境保护实验室"},{"_id":"6a7d793e0636ba417e41a7e3","lab_id":"69ad52a3de79e566650fb674","country":"PL","accr_number":"AB 1261","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna:","parameters":[{"name":"Apatyty i fosforyty"},{"name":"Cement portlandzki"},{"name":"Ditlenek tytanu"},{"name":"Grafit syntetyczny"},{"name":"Kaolin"},{"name":"Pyły drewna"},{"name":"Pyły mąki"},{"name":"Pyły niesklasyfikowane ze względu na toksyczność"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Sadza techniczna"},{"name":"Siarczan (VI) wapnia (gips)"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Węglan magnezu, wapnia (dolomit)"},{"name":"Węglik krzemu, niewłóknisty"},{"name":"Zakres","range":"(0,20 - 81,67) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit syntetyczny\nKaolin\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSadza techniczna\nSiarczan (VI) wapnia (gips)\nWęgiel (kamienny, brunatny)\nWęglan magnezu, wapnia (dolomit)\nWęglik krzemu, niewłóknisty\nZakres (0,20 - 81,67) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05+Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05+Ap1:2022-08"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit syntetyczny\nKaolin\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSadza techniczna\nSiarczan (VI) wapnia (gips)\nWęgiel (kamienny, brunatny)\nWęglan magnezu, wapnia (dolomit)\nWęglik krzemu, niewłóknisty\nZakres (0,20 - 81,67) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05+Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia – frakcja wdychalna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit syntetyczny\nKaolin\nPyly drewna\nPyly maki\nPyly niesklasyfikowane ze wzgledu na toksycznosc\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nSadza techniczna\nSiarczan (VI) wapnia (gips)\nWegiel (kamienny, brunatny)\nWeglan magnezu, wapnia (dolomit)\nWeglik krzemu, niewloknisty\nZakres (0,20 - 81,67) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05+Ap1:2022-08","categories":["environment","construction"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Concentration of harmful dust agents – inhalable fraction:","parameters_en":[{"name":"Apatites and phosphorites"},{"name":"Portland cement"},{"name":"Titanium dioxide"},{"name":"Synthetic graphite"},{"name":"Kaolin"},{"name":"Wood dusts"},{"name":"Flour dusts"},{"name":"Dusts not classified according to toxicity"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Carbon black"},{"name":"Calcium sulfate (VI) (gypsum)"},{"name":"Coal (hard, brown)"},{"name":"Magnesium, calcium carbonate (dolomite)"},{"name":"Silicon carbide, non-fibrous"},{"name":"Range","range":"(0,20 - 81,67) mg/m3"}],"search_en":"Workplace environment - air Concentration of harmful dust agents – inhalable fraction: Gravimetric method Environmental Protection Laboratory Apatites and phosphorites Portland cement Titanium dioxide Synthetic graphite Kaolin Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Carbon black Calcium sulfate (VI) (gypsum) Coal (hard, brown) Magnesium, calcium carbonate (dolomite) Silicon carbide, non-fibrous Range PN-Z-04507:2022-05+Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"二氧化钛"},{"name":"合成石墨"},{"name":"高岭土"},{"name":"木粉尘"},{"name":"面粉粉尘"},{"name":"未按毒性分类的粉尘"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"炭黑"},{"name":"硫酸钙（VI）（石膏）"},{"name":"煤（烟煤、褐煤）"},{"name":"镁钙碳酸盐（白云石）"},{"name":"碳化硅，非纤维状"},{"name":"范围","range":"(0,20 - 81,67) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 可吸入组分： 重量法 环境保护实验室 磷灰石与磷块岩 硅酸盐水泥 二氧化钛 合成石墨 高岭土 木粉尘 面粉粉尘 未按毒性分类的粉尘 动植物来源有机粉尘，木粉和面粉除外 炭黑 硫酸钙（VI）（石膏） 煤（烟煤、褐煤） 镁钙碳酸盐（白云石） 碳化硅，非纤维状 范围 PN-Z-04507:2022-05+Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"环境保护实验室","methodology_zh":"有害粉尘因素浓度 — 可吸入组分："},{"_id":"6a7d793e0636ba417e41a7e4","lab_id":"69ad52a3de79e566650fb674","country":"PL","accr_number":"AB 1261","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna:","parameters":[{"name":"Apatyty i fosforyty"},{"name":"Cement portlandzki"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Zakres","range":"(0,20 - 87,72) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nWęgiel (kamienny, brunatny)\nZakres (0,20 - 87,72) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04508:2022-05+Ap1:2022-08","norm_bases":["PN-Z-04508:2022-05+Ap1:2022-08"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nWęgiel (kamienny, brunatny)\nZakres (0,20 - 87,72) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05+Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia – frakcja respirabilna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nWegiel (kamienny, brunatny)\nZakres (0,20 - 87,72) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05+Ap1:2022-08","categories":["environment","construction"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Concentration of harmful dust agents – respirable fraction:","parameters_en":[{"name":"Apatites and phosphorites"},{"name":"Portland cement"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Coal (hard, brown)"},{"name":"Range","range":"(0,20 - 87,72) mg/m3"}],"search_en":"Workplace environment - air Concentration of harmful dust agents – respirable fraction: Gravimetric method Environmental Protection Laboratory Apatites and phosphorites Portland cement Organic dusts of animal and plant origin, excluding wood and flour dusts Coal (hard, brown) Range PN-Z-04508:2022-05+Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"煤（烟煤、褐煤）"},{"name":"范围","range":"(0,20 - 87,72) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 呼吸性组分： 重量法 环境保护实验室 磷灰石与磷块岩 硅酸盐水泥 动植物来源有机粉尘，木粉和面粉除外 煤（烟煤、褐煤） 范围 PN-Z-04508:2022-05+Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"环境保护实验室","methodology_zh":"有害粉尘因素浓度 — 呼吸性组分："},{"_id":"6a7d793e0636ba417e41a7e5","lab_id":"69ad52a3de79e566650fb674","country":"PL","accr_number":"AB 1261","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie fluorków w przeliczeniu na F -","parameters":[{"name":"Zakres","range":"(0,028- 4,166) mg/m3"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"Stężenie fluorków w przeliczeniu na F -\nZakres (0,028- 4,166) mg/m3\nMetoda potencjometryczna","reference":"NIOSH method 7902 Issue 2, date 15 August 1994","norm_bases":["NIOSH method 7902 Issue 2, date 15 August 1994"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie fluorków w przeliczeniu na F -\nZakres (0,028- 4,166) mg/m3\nMetoda potencjometryczna NIOSH method 7902 Issue 2, date 15 August 1994 Srodowisko pracy - powietrze Stezenie fluorkow w przeliczeniu na F -\nZakres (0,028- 4,166) mg/m3\nMetoda potencjometryczna NIOSH method 7902 Issue 2, date 15 August 1994","categories":["environment"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Fluoride concentration calculated as F -","parameters_en":[{"name":"Range","range":"(0,028- 4,166) mg/m3"}],"search_en":"Workplace environment - air Fluoride concentration calculated as F - Potentiometric method Environmental Protection Laboratory Range NIOSH method 7902 Issue 2, date 15 August 1994","technique_en":"Potentiometric method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"范围","range":"(0,028- 4,166) mg/m3"}],"search_zh":"工作场所环境 — 空气 电位法 环境保护实验室 范围 NIOSH method 7902 Issue 2, date 15 August 1994","technique_zh":"电位法","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"环境保护实验室"},{"_id":"6a7d793e0636ba417e41a7e6","lab_id":"69ad52a3de79e566650fb674","country":"PL","accr_number":"AB 1261","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie fluorowodoru","parameters":[{"name":"Zakres","range":"(0,015 – 4,387) mg/m3"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"Stężenie fluorowodoru\nZakres (0,015 – 4,387) mg/m3\nMetoda potencjometryczna","reference":"NIOSH method 7902 Issue 2, date 15 August 1994","norm_bases":["NIOSH method 7902 Issue 2, date 15 August 1994"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie fluorowodoru\nZakres (0,015 – 4,387) mg/m3\nMetoda potencjometryczna NIOSH method 7902 Issue 2, date 15 August 1994 Srodowisko pracy - powietrze Stezenie fluorowodoru\nZakres (0,015 – 4,387) mg/m3\nMetoda potencjometryczna NIOSH method 7902 Issue 2, date 15 August 1994","categories":["environment"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Hydrogen fluoride concentration","parameters_en":[{"name":"Range","range":"(0,015 – 4,387) mg/m3"}],"search_en":"Workplace environment - air Hydrogen fluoride concentration Potentiometric method Environmental Protection Laboratory Range NIOSH method 7902 Issue 2, date 15 August 1994","technique_en":"Potentiometric method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"范围","range":"(0,015 – 4,387) mg/m3"}],"search_zh":"工作场所环境 — 空气 氟化氢浓度 电位法 环境保护实验室 范围 NIOSH method 7902 Issue 2, date 15 August 1994","technique_zh":"电位法","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"环境保护实验室","methodology_zh":"氟化氢浓度"},{"_id":"6a7d793e0636ba417e41a7e7","lab_id":"69ad52a3de79e566650fb674","country":"PL","accr_number":"AB 1261","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie amoniaku","parameters":[{"name":"Zakres","range":"(0,75 - 50,00) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie amoniaku\nZakres (0,75 - 50,00) mg/m3\nMetoda spektrofotometryczna","reference":"PN-71/Z-04041","norm_bases":["PN-71/Z-04041"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie amoniaku\nZakres (0,75 - 50,00) mg/m3\nMetoda spektrofotometryczna PN-71/Z-04041 Srodowisko pracy - powietrze Stezenie amoniaku\nZakres (0,75 - 50,00) mg/m3\nMetoda spektrofotometryczna PN-71/Z-04041","categories":["environment"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Ammonia concentration","parameters_en":[{"name":"Range","range":"(0,75 - 50,00) mg/m3"}],"search_en":"Workplace environment - air Ammonia concentration Spectrophotometric method Environmental Protection Laboratory Range PN-71/Z-04041","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"范围","range":"(0,75 - 50,00) mg/m3"}],"search_zh":"工作场所环境 — 空气 氨浓度 分光光度法 环境保护实验室 范围 PN-71/Z-04041","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"氨浓度","lab_section_zh":"环境保护实验室"},{"_id":"6a7d793e0636ba417e41a7e8","lab_id":"69ad52a3de79e566650fb674","country":"PL","accr_number":"AB 1261","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie chlorowodoru","parameters":[{"name":"Zakres","range":"(0,50 - 50,00) mg/m3"}],"technique":"Metoda turbidymetryczna","techniques":["Metoda turbidymetryczna"],"computed":[],"activity":"Stężenie chlorowodoru\nZakres (0,50 - 50,00) mg/m3\nMetoda turbidymetryczna","reference":"PN-Z-04450:2014-08","norm_bases":["PN-Z-04450:2014-08"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie chlorowodoru\nZakres (0,50 - 50,00) mg/m3\nMetoda turbidymetryczna PN-Z-04450:2014-08 Srodowisko pracy - powietrze Stezenie chlorowodoru\nZakres (0,50 - 50,00) mg/m3\nMetoda turbidymetryczna PN-Z-04450:2014-08","categories":["environment"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Hydrogen chloride concentration","parameters_en":[{"name":"Range","range":"(0,50 - 50,00) mg/m3"}],"search_en":"Workplace environment - air Hydrogen chloride concentration Turbidimetric method Environmental Protection Laboratory Range PN-Z-04450:2014-08","technique_en":"Turbidimetric method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"范围","range":"(0,50 - 50,00) mg/m3"}],"search_zh":"工作场所环境 — 空气 氯化氢浓度 浊度法 环境保护实验室 范围 PN-Z-04450:2014-08","test_object_zh":"工作场所环境 — 空气","technique_zh":"浊度法","lab_section_zh":"环境保护实验室","methodology_zh":"氯化氢浓度"},{"_id":"6a7d793e0636ba417e41a7e9","lab_id":"69ad52a3de79e566650fb674","country":"PL","accr_number":"AB 1261","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie dwutlenku siarki","parameters":[{"name":"Zakres","range":"(0,16 - 6,40) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie dwutlenku siarki\nZakres (0,16 - 6,40) mg/m3\nMetoda spektrofotometryczna","reference":"PN-Z-04015-12:1996+Ap1:2001","norm_bases":["PN-Z-04015-12:1996+Ap1:2001"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie dwutlenku siarki\nZakres (0,16 - 6,40) mg/m3\nMetoda spektrofotometryczna PN-Z-04015-12:1996+Ap1:2001 Srodowisko pracy - powietrze Stezenie dwutlenku siarki\nZakres (0,16 - 6,40) mg/m3\nMetoda spektrofotometryczna PN-Z-04015-12:1996+Ap1:2001","categories":["environment"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Sulphur dioxide concentration","parameters_en":[{"name":"Range","range":"(0,16 - 6,40) mg/m3"}],"search_en":"Workplace environment - air Sulphur dioxide concentration Spectrophotometric method Environmental Protection Laboratory Range PN-Z-04015-12:1996+Ap1:2001","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"范围","range":"(0,16 - 6,40) mg/m3"}],"search_zh":"工作场所环境 — 空气 二氧化硫浓度 分光光度法 环境保护实验室 范围 PN-Z-04015-12:1996+Ap1:2001","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"环境保护实验室","methodology_zh":"二氧化硫浓度"},{"_id":"6a7d793e0636ba417e41a7ea","lab_id":"69ad52a3de79e566650fb674","country":"PL","accr_number":"AB 1261","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie manganu i jego związków nieorganicznych w przeliczeniu na Mn","parameters":[{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(0,02 - 0,40) mg/m3"},{"name":"frakcja respirabilna"},{"name":"Zakres","range":"(0,005 - 0,100) mg/m3"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie manganu i jego związków nieorganicznych w przeliczeniu na Mn\nZakres:\nfrakcja wdychalna\nZakres (0,02 - 0,40) mg/m3\nfrakcja respirabilna\nZakres (0,005 - 0,100) mg/m3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04472:2015-10+Ap1:2015-12","norm_bases":["PN-Z-04472:2015-10+Ap1:2015-12"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie manganu i jego związków nieorganicznych w przeliczeniu na Mn\nZakres:\nfrakcja wdychalna\nZakres (0,02 - 0,40) mg/m3\nfrakcja respirabilna\nZakres (0,005 - 0,100) mg/m3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04472:2015-10+Ap1:2015-12 Srodowisko pracy - powietrze Stezenie manganu i jego zwiazkow nieorganicznych w przeliczeniu na Mn\nZakres:\nfrakcja wdychalna\nZakres (0,02 - 0,40) mg/m3\nfrakcja respirabilna\nZakres (0,005 - 0,100) mg/m3\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04472:2015-10+Ap1:2015-12","categories":["environment"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Concentration of manganese and its inorganic compounds calculated as Mn","parameters_en":[{"name":"inhalable fraction"},{"name":"Range","range":"(0,02 - 0,40) mg/m3"},{"name":"respirable fraction"},{"name":"Range","range":"(0,005 - 0,100) mg/m3"}],"search_en":"Workplace environment - air Concentration of manganese and its inorganic compounds calculated as Mn Flame atomic absorption spectrometry (FAAS) Environmental Protection Laboratory inhalable fraction Range respirable fraction Range PN-Z-04472:2015-10+Ap1:2015-12","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"可吸入组分"},{"name":"范围","range":"(0,02 - 0,40) mg/m3"},{"name":"呼吸性组分"},{"name":"范围","range":"(0,005 - 0,100) mg/m3"}],"search_zh":"工作场所环境 — 空气 锰及其无机化合物浓度（以 Mn 计） 火焰原子吸收光谱法（FAAS） 环境保护实验室 可吸入组分 范围 呼吸性组分 范围 PN-Z-04472:2015-10+Ap1:2015-12","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"环境保护实验室","methodology_zh":"锰及其无机化合物浓度（以 Mn 计）"},{"_id":"6a7d793e0636ba417e41a7eb","lab_id":"69ad52a3de79e566650fb674","country":"PL","accr_number":"AB 1261","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie tlenków żelaza w przeliczeniu na Fe","parameters":[{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(0,50 – 20,00) mg/m3"},{"name":"frakcja respirabilna"},{"name":"Zakres","range":"(0,25 - 10,00) mg/m3"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie tlenków żelaza w przeliczeniu na Fe\nZakres:\nfrakcja wdychalna\nZakres (0,50 – 20,00) mg/m3\nfrakcja respirabilna\nZakres (0,25 - 10,00) mg/m3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04469:2025-02","norm_bases":["PN-Z-04469:2025-02"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie tlenków żelaza w przeliczeniu na Fe\nZakres:\nfrakcja wdychalna\nZakres (0,50 – 20,00) mg/m3\nfrakcja respirabilna\nZakres (0,25 - 10,00) mg/m3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04469:2025-02 Srodowisko pracy - powietrze Stezenie tlenkow zelaza w przeliczeniu na Fe\nZakres:\nfrakcja wdychalna\nZakres (0,50 – 20,00) mg/m3\nfrakcja respirabilna\nZakres (0,25 - 10,00) mg/m3\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04469:2025-02","categories":["environment"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Concentration of iron oxides calculated as Fe","parameters_en":[{"name":"inhalable fraction"},{"name":"Range","range":"(0,50 – 20,00) mg/m3"},{"name":"respirable fraction"},{"name":"Range","range":"(0,25 - 10,00) mg/m3"}],"search_en":"Workplace environment - air Concentration of iron oxides calculated as Fe Flame atomic absorption spectrometry (FAAS) Environmental Protection Laboratory inhalable fraction Range respirable fraction Range PN-Z-04469:2025-02","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"可吸入组分"},{"name":"范围","range":"(0,50 – 20,00) mg/m3"},{"name":"呼吸性组分"},{"name":"范围","range":"(0,25 - 10,00) mg/m3"}],"search_zh":"工作场所环境 — 空气 铁氧化物浓度（以 Fe 计） 火焰原子吸收光谱法（FAAS） 环境保护实验室 可吸入组分 范围 呼吸性组分 范围 PN-Z-04469:2025-02","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"环境保护实验室","methodology_zh":"铁氧化物浓度（以 Fe 计）"},{"_id":"6a7d793e0636ba417e41a7ec","lab_id":"69ad52a3de79e566650fb674","country":"PL","accr_number":"AB 1261","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie kwasu fosforowego (V)","parameters":[{"name":"Zakres","range":"(0,10 - 10,32) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie kwasu fosforowego (V)\nZakres (0,10 - 10,32) mg/m3\nMetoda spektrofotometryczna","reference":"PN-Z-04073-1:2014-08","norm_bases":["PN-Z-04073-1:2014-08"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie kwasu fosforowego (V)\nZakres (0,10 - 10,32) mg/m3\nMetoda spektrofotometryczna PN-Z-04073-1:2014-08 Srodowisko pracy - powietrze Stezenie kwasu fosforowego (V)\nZakres (0,10 - 10,32) mg/m3\nMetoda spektrofotometryczna PN-Z-04073-1:2014-08","categories":["environment"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Phosphoric (V) acid concentration","parameters_en":[{"name":"Range","range":"(0,10 - 10,32) mg/m3"}],"search_en":"Workplace environment - air Phosphoric (V) acid concentration Spectrophotometric method Environmental Protection Laboratory Range PN-Z-04073-1:2014-08","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"范围","range":"(0,10 - 10,32) mg/m3"}],"search_zh":"工作场所环境 — 空气 磷酸(V)浓度 分光光度法 环境保护实验室 范围 PN-Z-04073-1:2014-08","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"环境保护实验室","methodology_zh":"磷酸(V)浓度"},{"_id":"6a7d793e0636ba417e41a7ed","lab_id":"69ad52a3de79e566650fb674","country":"PL","accr_number":"AB 1261","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtry","methodology":"Zawartość fluorków w przeliczeniu na F -","parameters":[{"name":"Zakres","range":"(0,020-0,300) mg w próbce"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"Zawartość fluorków w przeliczeniu na F -\nZakres (0,020-0,300) mg w próbce\nMetoda potencjometryczna","reference":"NIOSH method 7902 Issue 2, date 15 August 1994","norm_bases":["NIOSH method 7902 Issue 2, date 15 August 1994"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtry Zawartość fluorków w przeliczeniu na F -\nZakres (0,020-0,300) mg w próbce\nMetoda potencjometryczna NIOSH method 7902 Issue 2, date 15 August 1994 Srodowisko pracy - probki powietrza pobrane na filtry Zawartosc fluorkow w przeliczeniu na F -\nZakres (0,020-0,300) mg w probce\nMetoda potencjometryczna NIOSH method 7902 Issue 2, date 15 August 1994","categories":["environment"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Fluoride content calculated as F -","parameters_en":[{"name":"Range","range":"(0,020-0,300) mg w próbce"}],"search_en":"Workplace environment - air samples collected on filters Fluoride content calculated as F - Potentiometric method Environmental Protection Laboratory Range NIOSH method 7902 Issue 2, date 15 August 1994","technique_en":"Potentiometric method","test_object_en":"Workplace environment - air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,020-0,300) mg w próbce"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 电位法 环境保护实验室 范围 NIOSH method 7902 Issue 2, date 15 August 1994","technique_zh":"电位法","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品","lab_section_zh":"环境保护实验室"},{"_id":"6a7d793e0636ba417e41a7ee","lab_id":"69ad52a3de79e566650fb674","country":"PL","accr_number":"AB 1261","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtry","methodology":"Zawartość manganu i jego związków nieorganicznych w przeliczeniu na Mn","parameters":[{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(0,012 - 0,240) mg w próbce"},{"name":"frakcja respirabilna"},{"name":"Zakres","range":"(0,003 - 0,060) mg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość manganu i jego związków nieorganicznych w przeliczeniu na Mn\nZakres:\nfrakcja wdychalna\nZakres (0,012 - 0,240) mg w próbce\nfrakcja respirabilna\nZakres (0,003 - 0,060) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04472:2015-10+Ap1:2015-12","norm_bases":["PN-Z-04472:2015-10+Ap1:2015-12"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtry Zawartość manganu i jego związków nieorganicznych w przeliczeniu na Mn\nZakres:\nfrakcja wdychalna\nZakres (0,012 - 0,240) mg w próbce\nfrakcja respirabilna\nZakres (0,003 - 0,060) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04472:2015-10+Ap1:2015-12 Srodowisko pracy - probki powietrza pobrane na filtry Zawartosc manganu i jego zwiazkow nieorganicznych w przeliczeniu na Mn\nZakres:\nfrakcja wdychalna\nZakres (0,012 - 0,240) mg w probce\nfrakcja respirabilna\nZakres (0,003 - 0,060) mg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04472:2015-10+Ap1:2015-12","categories":["environment"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Content of manganese and its inorganic compounds calculated as Mn","parameters_en":[{"name":"inhalable fraction"},{"name":"Range","range":"(0,012 - 0,240) mg w próbce"},{"name":"respirable fraction"},{"name":"Range","range":"(0,003 - 0,060) mg w próbce"}],"search_en":"Workplace environment - air samples collected on filters Content of manganese and its inorganic compounds calculated as Mn Flame atomic absorption spectrometry (FAAS) Environmental Protection Laboratory inhalable fraction Range respirable fraction Range PN-Z-04472:2015-10+Ap1:2015-12","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment - air samples collected on filters","parameters_zh":[{"name":"可吸入组分"},{"name":"范围","range":"(0,012 - 0,240) mg w próbce"},{"name":"呼吸性组分"},{"name":"范围","range":"(0,003 - 0,060) mg w próbce"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 锰及其无机化合物含量（以 Mn 计） 火焰原子吸收光谱法（FAAS） 环境保护实验室 可吸入组分 范围 呼吸性组分 范围 PN-Z-04472:2015-10+Ap1:2015-12","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品","lab_section_zh":"环境保护实验室","methodology_zh":"锰及其无机化合物含量（以 Mn 计）"},{"_id":"6a7d793e0636ba417e41a7ef","lab_id":"69ad52a3de79e566650fb674","country":"PL","accr_number":"AB 1261","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtry","methodology":"Zawartość tlenków żelaza w przeliczeniu na Fe - frakcja wdychalna","parameters":[{"name":"Zakres","range":"(0,36 - 14,40) mg w próbce"},{"name":"frakcja respirabilna"},{"name":"Zakres","range":"(0,18 - 7,20) mg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość tlenków żelaza w przeliczeniu na Fe - frakcja wdychalna\nZakres:\nZakres (0,36 - 14,40) mg w próbce\nfrakcja respirabilna\nZakres (0,18 - 7,20) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04469:2025-02","norm_bases":["PN-Z-04469:2025-02"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtry Zawartość tlenków żelaza w przeliczeniu na Fe - frakcja wdychalna\nZakres:\nZakres (0,36 - 14,40) mg w próbce\nfrakcja respirabilna\nZakres (0,18 - 7,20) mg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04469:2025-02 Srodowisko pracy - probki powietrza pobrane na filtry Zawartosc tlenkow zelaza w przeliczeniu na Fe - frakcja wdychalna\nZakres:\nZakres (0,36 - 14,40) mg w probce\nfrakcja respirabilna\nZakres (0,18 - 7,20) mg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04469:2025-02","categories":["environment"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Content of iron oxides expressed as Fe - inhalable fraction","parameters_en":[{"name":"Range","range":"(0,36 - 14,40) mg w próbce"},{"name":"respirable fraction"},{"name":"Range","range":"(0,18 - 7,20) mg w próbce"}],"search_en":"Workplace environment - air samples collected on filters Content of iron oxides expressed as Fe - inhalable fraction Flame atomic absorption spectrometry (FAAS) Environmental Protection Laboratory Range respirable fraction Range PN-Z-04469:2025-02","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment - air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,36 - 14,40) mg w próbce"},{"name":"呼吸性组分"},{"name":"范围","range":"(0,18 - 7,20) mg w próbce"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 火焰原子吸收光谱法（FAAS） 环境保护实验室 范围 呼吸性组分 范围 PN-Z-04469:2025-02","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品","lab_section_zh":"环境保护实验室"},{"_id":"6a7d793e0636ba417e41a7f0","lab_id":"69ad52a3de79e566650fb674","country":"PL","accr_number":"AB 1261","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtry","methodology":"Zawartość chlorowodoru","parameters":[{"name":"Zakres","range":"(0,20 - 20,00) mg w próbce"}],"technique":"Metoda turbidymetryczna","techniques":["Metoda turbidymetryczna"],"computed":[],"activity":"Zawartość chlorowodoru\nZakres (0,20 - 20,00) mg w próbce\nMetoda turbidymetryczna","reference":"PN-Z-04450:2014-08","norm_bases":["PN-Z-04450:2014-08"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtry Zawartość chlorowodoru\nZakres (0,20 - 20,00) mg w próbce\nMetoda turbidymetryczna PN-Z-04450:2014-08 Srodowisko pracy - probki powietrza pobrane na filtry Zawartosc chlorowodoru\nZakres (0,20 - 20,00) mg w probce\nMetoda turbidymetryczna PN-Z-04450:2014-08","categories":["environment"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Hydrogen chloride content","parameters_en":[{"name":"Range","range":"(0,20 - 20,00) mg w próbce"}],"search_en":"Workplace environment - air samples collected on filters Hydrogen chloride content Turbidimetric method Environmental Protection Laboratory Range PN-Z-04450:2014-08","technique_en":"Turbidimetric method","test_object_en":"Workplace environment - air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,20 - 20,00) mg w próbce"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 氯化氢含量 浊度法 环境保护实验室 范围 PN-Z-04450:2014-08","technique_zh":"浊度法","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品","lab_section_zh":"环境保护实验室","methodology_zh":"氯化氢含量"},{"_id":"6a7d793e0636ba417e41a7f1","lab_id":"69ad52a3de79e566650fb674","country":"PL","accr_number":"AB 1261","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na filtry","methodology":"Zawartość fluorowodoru","parameters":[{"name":"Zakres","range":"(0,011 – 0,315) mg w próbce"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"Zawartość fluorowodoru\nZakres (0,011 – 0,315) mg w próbce\nMetoda potencjometryczna","reference":"NIOSH method 7902 Issue 2, date 15 August 1994","norm_bases":["NIOSH method 7902 Issue 2, date 15 August 1994"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na filtry Zawartość fluorowodoru\nZakres (0,011 – 0,315) mg w próbce\nMetoda potencjometryczna NIOSH method 7902 Issue 2, date 15 August 1994 Srodowisko pracy - probki powietrza pobrane na filtry Zawartosc fluorowodoru\nZakres (0,011 – 0,315) mg w probce\nMetoda potencjometryczna NIOSH method 7902 Issue 2, date 15 August 1994","categories":["environment"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Hydrogen fluoride content","parameters_en":[{"name":"Range","range":"(0,011 – 0,315) mg w próbce"}],"search_en":"Workplace environment - air samples collected on filters Hydrogen fluoride content Potentiometric method Environmental Protection Laboratory Range NIOSH method 7902 Issue 2, date 15 August 1994","technique_en":"Potentiometric method","test_object_en":"Workplace environment - air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,011 – 0,315) mg w próbce"}],"search_zh":"工作场所环境 — 用滤膜采集的空气样品 氟化氢含量 电位法 环境保护实验室 范围 NIOSH method 7902 Issue 2, date 15 August 1994","technique_zh":"电位法","test_object_zh":"工作场所环境 — 用滤膜采集的空气样品","lab_section_zh":"环境保护实验室","methodology_zh":"氟化氢含量"},{"_id":"6a7d793e0636ba417e41a7f2","lab_id":"69ad52a3de79e566650fb674","country":"PL","accr_number":"AB 1261","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane do roztworu pochłaniającego","methodology":"Zawartość amoniaku","parameters":[{"name":"Zakres","range":"(0,045 - 3,000) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość amoniaku\nZakres (0,045 - 3,000) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-71/Z-04041","norm_bases":["PN-71/Z-04041"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane do roztworu pochłaniającego Zawartość amoniaku\nZakres (0,045 - 3,000) mg w próbce\nMetoda spektrofotometryczna PN-71/Z-04041 Srodowisko pracy - probki powietrza pobrane do roztworu pochlaniajacego Zawartosc amoniaku\nZakres (0,045 - 3,000) mg w probce\nMetoda spektrofotometryczna PN-71/Z-04041","categories":["environment"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Ammonia content","parameters_en":[{"name":"Range","range":"(0,045 - 3,000) mg w próbce"}],"search_en":"Workplace environment - air samples collected into absorbing solution Ammonia content Spectrophotometric method Environmental Protection Laboratory Range PN-71/Z-04041","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment - air samples collected into absorbing solution","parameters_zh":[{"name":"范围","range":"(0,045 - 3,000) mg w próbce"}],"search_zh":"工作环境 － 采集于吸收液中的空气样品 氨含量 分光光度法 环境保护实验室 范围 PN-71/Z-04041","technique_zh":"分光光度法","lab_section_zh":"环境保护实验室","methodology_zh":"氨含量","test_object_zh":"工作环境 － 采集于吸收液中的空气样品"},{"_id":"6a7d793e0636ba417e41a7f3","lab_id":"69ad52a3de79e566650fb674","country":"PL","accr_number":"AB 1261","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane do roztworu pochłaniającego","methodology":"Zawartość ditlenku siarki","parameters":[{"name":"Zakres","range":"(0,0016 - 0,0640) mg w"},{"name":"próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość ditlenku siarki\nZakres:\nZakres (0,0016 - 0,0640) mg w\npróbce\nMetoda spektrofotometryczna","reference":"PN-Z-04015-12:1996+Ap1:2001","norm_bases":["PN-Z-04015-12:1996+Ap1:2001"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane do roztworu pochłaniającego Zawartość ditlenku siarki\nZakres:\nZakres (0,0016 - 0,0640) mg w\npróbce\nMetoda spektrofotometryczna PN-Z-04015-12:1996+Ap1:2001 Srodowisko pracy - probki powietrza pobrane do roztworu pochlaniajacego Zawartosc ditlenku siarki\nZakres:\nZakres (0,0016 - 0,0640) mg w\nprobce\nMetoda spektrofotometryczna PN-Z-04015-12:1996+Ap1:2001","categories":["environment"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Sulfur dioxide content","parameters_en":[{"name":"Range","range":"(0,0016 - 0,0640) mg w"},{"name":"sample"}],"search_en":"Workplace environment - air samples collected into absorbing solution Sulfur dioxide content Spectrophotometric method Environmental Protection Laboratory Range sample PN-Z-04015-12:1996+Ap1:2001","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment - air samples collected into absorbing solution","parameters_zh":[{"name":"范围","range":"(0,0016 - 0,0640) mg w"},{"name":"样品中"}],"search_zh":"工作环境 － 采集于吸收液中的空气样品 二氧化硫含量 分光光度法 环境保护实验室 范围 样品中 PN-Z-04015-12:1996+Ap1:2001","technique_zh":"分光光度法","lab_section_zh":"环境保护实验室","test_object_zh":"工作环境 － 采集于吸收液中的空气样品","methodology_zh":"二氧化硫含量"},{"_id":"6a7d793e0636ba417e41a7f4","lab_id":"69ad52a3de79e566650fb674","country":"PL","accr_number":"AB 1261","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane do roztworu pochłaniającego","methodology":"Zawartość kwasu fosforowego (V)","parameters":[{"name":"Zakres","range":"(0,00206 - 0,10316) mg w"},{"name":"próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość kwasu fosforowego (V)\nZakres:\nZakres (0,00206 - 0,10316) mg w\npróbce\nMetoda spektrofotometryczna","reference":"PN-Z-04073-1:2014-08","norm_bases":["PN-Z-04073-1:2014-08"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane do roztworu pochłaniającego Zawartość kwasu fosforowego (V)\nZakres:\nZakres (0,00206 - 0,10316) mg w\npróbce\nMetoda spektrofotometryczna PN-Z-04073-1:2014-08 Srodowisko pracy - probki powietrza pobrane do roztworu pochlaniajacego Zawartosc kwasu fosforowego (V)\nZakres:\nZakres (0,00206 - 0,10316) mg w\nprobce\nMetoda spektrofotometryczna PN-Z-04073-1:2014-08","categories":["environment"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Phosphoric (V) acid content","parameters_en":[{"name":"Range","range":"(0,00206 - 0,10316) mg w"},{"name":"sample"}],"search_en":"Workplace environment - air samples collected into absorbing solution Phosphoric (V) acid content Spectrophotometric method Environmental Protection Laboratory Range sample PN-Z-04073-1:2014-08","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment - air samples collected into absorbing solution","parameters_zh":[{"name":"范围","range":"(0,00206 - 0,10316) mg w"},{"name":"样品中"}],"search_zh":"工作环境 － 采集于吸收液中的空气样品 分光光度法 环境保护实验室 范围 样品中 PN-Z-04073-1:2014-08","technique_zh":"分光光度法","lab_section_zh":"环境保护实验室","test_object_zh":"工作环境 － 采集于吸收液中的空气样品"},{"_id":"6a7d793e0636ba417e41a7f5","lab_id":"69ad52a3de79e566650fb674","country":"PL","accr_number":"AB 1261","accr_body":"PCA","test_object":"Środowisko pracy – hałas","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(25,0 - 137,0) dB"},{"name":"Szczytowy poziom dźwięku C"},{"name":"Zakres","range":"(25,0 - 137) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (25,0 - 137,0) dB\nSzczytowy poziom dźwięku C\nZakres (25,0 - 137) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i 3 - punkt 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i 3 - punkt 10 i 11"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (25,0 - 137,0) dB\nSzczytowy poziom dźwięku C\nZakres (25,0 - 137) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i 3 - punkt 10 i 11 Srodowisko pracy – halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres:\nZakres (25,0 - 137,0) dB\nSzczytowy poziom dzwieku C\nZakres (25,0 - 137) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej Strategie 2 i 3 - punkt 10 i 11","categories":["environment"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters_en":[{"name":"Range","range":"(25,0 - 137,0) dB"},{"name":"C-weighted peak sound pressure level"},{"name":"Range","range":"(25,0 - 137) dB"}],"search_en":"Workplace environment – noise A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method Environmental Protection Laboratory Range C-weighted peak sound pressure level Range PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i 3 - punkt 10 i 11","technique_en":"Direct measurement method","test_object_en":"Workplace environment – noise","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(25,0 - 137,0) dB"},{"name":"C 计权峰值声级"},{"name":"范围","range":"(25,0 - 137) dB"}],"search_zh":"工作场所环境 — 噪声 A 计权等效声级 A 计权最大声级 直接测量法 环境保护实验室 范围 C 计权峰值声级 范围 PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i 3 - punkt 10 i 11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声","lab_section_zh":"环境保护实验室"},{"_id":"6a7d793e0636ba417e41a7f6","lab_id":"69ad52a3de79e566650fb674","country":"PL","accr_number":"AB 1261","accr_body":"PCA","test_object":"Środowisko pracy – hałas","methodology":"Poziom ekspozycji na hałas odniesiony do:","parameters":[{"name":"8-godz. dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i 3 - punkt 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i 3 - punkt 10 i 11"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i 3 - punkt 10 i 11 Srodowisko pracy – halas Poziom ekspozycji na halas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej Strategie 2 i 3 - punkt 10 i 11","categories":["environment"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Noise exposure level referred to:","parameters_en":[{"name":"an 8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"search_en":"Workplace environment – noise Noise exposure level referred to: Environmental Protection Laboratory an 8-hour daily working time the average weekly working time (calculated) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i 3 - punkt 10 i 11","test_object_en":"Workplace environment – noise","methodology_zh":"噪声暴露级，参照：","parameters_zh":[{"name":"8 小时日工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作场所环境 — 噪声 噪声暴露级，参照： 环境保护实验室 8 小时日工作时间 平均每周工作时间（计算值） PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 i 3 - punkt 10 i 11","test_object_zh":"工作场所环境 — 噪声","lab_section_zh":"环境保护实验室"},{"_id":"6a7d793e0636ba417e41a7f7","lab_id":"69ad52a3de79e566650fb674","country":"PL","accr_number":"AB 1261","accr_body":"PCA","test_object":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(25,0 - 137,0) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres (25,0 - 137,0) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j.Dz.U.2023 poz.1706) z wyłączeniem punktu F","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j.Dz.U.2023 poz.1706) z wyłączeniem punktu F"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A\nZakres (25,0 - 137,0) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j.Dz.U.2023 poz.1706) z wyłączeniem punktu F Srodowisko ogolne - halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A\nZakres (25,0 - 137,0) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j.Dz.U.2023 poz.1706) z wylaczeniem punktu F","categories":["environment"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"A-weighted equivalent sound pressure level","parameters_en":[{"name":"Range","range":"(25,0 - 137,0) dB"}],"search_en":"General environment - noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level Direct measurement method Environmental Protection Laboratory Range Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j.Dz.U.2023 poz.1706) z wyłączeniem punktu F","technique_en":"Direct measurement method","test_object_en":"General environment - noise from installations, equipment and industrial plants","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(25,0 - 137,0) dB"}],"search_zh":"一般环境 — 来自装置、设备和工业企业的噪声 A 计权等效声级 直接测量法 环境保护实验室 范围 Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j.Dz.U.2023 poz.1706) z wyłączeniem punktu F","technique_zh":"直接测量法","test_object_zh":"一般环境 — 来自装置、设备和工业企业的噪声","lab_section_zh":"环境保护实验室"},{"_id":"6a7d793e0636ba417e41a7f8","lab_id":"69ad52a3de79e566650fb674","country":"PL","accr_number":"AB 1261","accr_body":"PCA","test_object":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j.Dz.U.2023 poz.1706) z wyłączeniem punktu F","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j.Dz.U.2023 poz.1706) z wyłączeniem punktu F"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j.Dz.U.2023 poz.1706) z wyłączeniem punktu F Srodowisko ogolne - halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j.Dz.U.2023 poz.1706) z wylaczeniem punktu F","categories":["environment"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","search_en":"General environment - noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Environmental Protection Laboratory Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j.Dz.U.2023 poz.1706) z wyłączeniem punktu F","test_object_en":"General environment - noise from installations, equipment and industrial plants","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 — 来自装置、设备和工业企业的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） 环境保护实验室 Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j.Dz.U.2023 poz.1706) z wyłączeniem punktu F","test_object_zh":"一般环境 — 来自装置、设备和工业企业的噪声","lab_section_zh":"环境保护实验室"},{"_id":"6a7d793e0636ba417e41a7f9","lab_id":"69ad52a3de79e566650fb674","country":"PL","accr_number":"AB 1261","accr_body":"PCA","test_object":"Woda","methodology":"Pobieranie próbek do badań fizycznych","parameters":[{"name":"Temperatura"},{"name":"Zakres","range":"(0,5 - 40,0) 0C"}],"technique":"Metoda manualna","techniques":["Metoda manualna"],"computed":[],"activity":"Pobieranie próbek do badań fizycznych\nZakres:\nTemperatura\nZakres (0,5 - 40,0) 0C\nMetoda manualna","reference":"PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2; 7.3; 7.5; 7.6 P N-77/C-04584","norm_bases":["PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2; 7.3; 7.5; 7.6 P N-77/C-04584"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Pobieranie próbek do badań fizycznych\nZakres:\nTemperatura\nZakres (0,5 - 40,0) 0C\nMetoda manualna PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2; 7.3; 7.5; 7.6 P N-77/C-04584 Woda Pobieranie probek do badan fizycznych\nZakres:\nTemperatura\nZakres (0,5 - 40,0) 0C\nMetoda manualna PN-EN ISO 5667-6:2016-12 z wylaczeniem pkt. 7.2; 7.3; 7.5; 7.6 P N-77/C-04584","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Sampling for physical testing","parameters_en":[{"name":"Temperature"},{"name":"Range","range":"(0,5 - 40,0) 0C"}],"search_en":"Water Sampling for physical testing Manual method Environmental Protection Laboratory Temperature Range PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2; 7.3; 7.5; 7.6 P N-77/C-04584","technique_en":"Manual method","test_object_en":"Water","parameters_zh":[{"name":"温度"},{"name":"范围","range":"(0,5 - 40,0) 0C"}],"search_zh":"水 手工法 环境保护实验室 温度 范围 PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2; 7.3; 7.5; 7.6 P N-77/C-04584","test_object_zh":"水","technique_zh":"手工法","lab_section_zh":"环境保护实验室"},{"_id":"6a7d793e0636ba417e41a7fa","lab_id":"69ad52a3de79e566650fb674","country":"PL","accr_number":"AB 1261","accr_body":"PCA","test_object":"Ścieki, Wody opadowe i roztopowe","methodology":"Pobieranie próbek do badań fizycznych","parameters":[{"name":"Temperatura"},{"name":"Zakres","range":"(0,5 - 40,0) 0C"}],"technique":"Metoda manualna","techniques":["Metoda manualna"],"computed":[],"activity":"Pobieranie próbek do badań fizycznych\nZakres:\nTemperatura\nZakres (0,5 - 40,0) 0C\nMetoda manualna","reference":"PN-ISO 5667-10:2021-11 | PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11","PN-77/C-04584"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, Wody opadowe i roztopowe Pobieranie próbek do badań fizycznych\nZakres:\nTemperatura\nZakres (0,5 - 40,0) 0C\nMetoda manualna PN-ISO 5667-10:2021-11 | PN-77/C-04584 Scieki, Wody opadowe i roztopowe Pobieranie probek do badan fizycznych\nZakres:\nTemperatura\nZakres (0,5 - 40,0) 0C\nMetoda manualna PN-ISO 5667-10:2021-11 | PN-77/C-04584","categories":["water"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Sampling for physical testing","parameters_en":[{"name":"Temperature"},{"name":"Range","range":"(0,5 - 40,0) 0C"}],"search_en":"Wastewater, Rainwater and snowmelt water Sampling for physical testing Manual method Environmental Protection Laboratory Temperature Range PN-ISO 5667-10:2021-11 | PN-77/C-04584","technique_en":"Manual method","test_object_en":"Wastewater, Rainwater and snowmelt water","parameters_zh":[{"name":"温度"},{"name":"范围","range":"(0,5 - 40,0) 0C"}],"search_zh":"废水、雨水与融雪水 手工法 环境保护实验室 温度 范围 PN-ISO 5667-10:2021-11 | PN-77/C-04584","technique_zh":"手工法","lab_section_zh":"环境保护实验室","test_object_zh":"废水、雨水与融雪水"},{"_id":"6a7d793e0636ba417e41a7fb","lab_id":"69ad52a3de79e566650fb674","country":"PL","accr_number":"AB 1261","accr_body":"PCA","test_object":"Woda, ścieki, Wody opadowe i roztopowe","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 - 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 - 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki, Wody opadowe i roztopowe pH\nZakres 2,0 - 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, scieki, Wody opadowe i roztopowe pH\nZakres 2,0 - 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 - 10,0"}],"search_en":"Water, wastewater, Rainwater and snowmelt water pH Potentiometric method Environmental Protection Laboratory Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, wastewater, Rainwater and snowmelt water","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 - 10,0"}],"search_zh":"pH 值 电位法 环境保护实验室 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","lab_section_zh":"环境保护实验室"},{"_id":"6a7d793e0636ba417e41a7fc","lab_id":"69ad52a3de79e566650fb674","country":"PL","accr_number":"AB 1261","accr_body":"PCA","test_object":"Woda, ścieki, Wody opadowe i roztopowe","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 - 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 - 1000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007 + Ap1:2007","norm_bases":["PN-EN 872:2007 + Ap1:2007"],"lab_section":"Laboratorium Ochrony Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki, Wody opadowe i roztopowe Zawiesiny ogólne\nZakres (2,0 - 1000) mg/l\nMetoda wagowa PN-EN 872:2007 + Ap1:2007 Woda, scieki, Wody opadowe i roztopowe Zawiesiny ogolne\nZakres (2,0 - 1000) mg/l\nMetoda wagowa PN-EN 872:2007 + Ap1:2007","categories":["water"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Protection Laboratory","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 - 1000) mg/l"}],"search_en":"Water, wastewater, Rainwater and snowmelt water Total suspended solids (TSS) Gravimetric method Environmental Protection Laboratory Range PN-EN 872:2007 + Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, wastewater, Rainwater and snowmelt water","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 - 1000) mg/l"}],"search_zh":"总悬浮物 重量法 环境保护实验室 范围 PN-EN 872:2007 + Ap1:2007","technique_zh":"重量法","lab_section_zh":"环境保护实验室"}],"has_pdf":true}