🇵🇱 EKOSYSTEMY - JT JERZY TETERYCZ PL

PCA AB 1254 • Zielona Góra, Poland • 35 methods

Water & wastewater

EKOSYSTEMY - JT JERZY TETERYCZ is a laboratory accredited by PCA under number AB 1254 (Zielona Góra, Poland). Its accreditation scope covers 35 test methods in the following areas: Water & wastewater. Test objects include: Water, Wastewater, Water, Swimming pool water, Wastewater. Most frequently used techniques: Spectrophotometric method, Titrimetric method, Flame atomic absorption spectrometry (FAAS).

At a glance

  • Accreditation number: PCA AB 1254
  • Methods in scope: 35
  • Types of test objects: 6
  • Techniques used: 12
  • City: Zielona Góra, Poland
Accreditation number
AB 1254
Accreditation body
PCA
Address
ul. Kożuchowska 10 e, 65-364 Zielona Góra
City
Zielona Góra, Poland

What this laboratory tests (6)

Analytical techniques used (12)

Accreditation scope — test methods (35)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Water intended for human consumption Sampling for physical, chemical and microbiological testing PN-ISO 5667-5:2017-10 | PN-EN ISO 19458:2007
2 Water Sampling for physical and chemical testing PN-ISO 5667-11:2017-10
3 Wastewater Sampling for physical and chemical testing
Temperature Range (2,0 – 60,0)oC
Manual method; Automatic method PN-ISO 5667-10:2021-11 | PB-24 wydanie 01 z dnia 10.10.2025 r.
4 Water Total hardness (Total calcium and magnesium content)
Range (2,5 – 1000) mg/l CaCO3
Titrimetric method PN-ISO 6059:1999
5 Water Calcium concentration
Range (2,0 – 400) mg/l
Titrimetric method PN-ISO 6058:1999
6 Water Magnesium concentration (calculated) PN-C-04554-4:1999
7 Water Electrical conductivity
Range (147 – 1413) μS/cm
Conductometric method PN-EN 27888:1999
8 Water Total phosphorus concentration
Range (0,05 - 25,0) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 pkt 7 +Ap1:2010+Ap2:2010
9 Water Turbidity
Range (0,2– 20) NTU
Nephelometric method PN EN ISO 7027-1:2006-09
10 Water Ammonium ion concentration
Range (0,06 – 1,58) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
11 Water Colour
Range (2 – 40) mg/l Pt
Spectrophotometric method PN-EN ISO 7887:2012 + Ap1:2015-06 metoda C
12 Swimming pool water pH
Range 2,0 – 10,0
Potentiometric method PN-EN ISO 10523:2012
13 Swimming pool water Nitrate nitrogen concentration
Range (0,05 – 20) mg/l
Spectrophotometric method PN-82/C-04576.08
14 Swimming pool water Iron concentration
Range (0,150 – 20,0) mg/l
Flame atomic absorption spectrometry (FAAS) PN-92/C-04570/01
15 Water, Wastewater pH
Range 2,0 – 10,0
Potentiometric method PN-EN ISO 10523:2012
16 Water, Wastewater Dissolved oxygen concentration
Range (0,5 – 14) mg/l O2
Optical method ISO 17289:2014
17 Water, Wastewater Ammonium nitrogen concentration
Range (0,25 – 100) mg/l
Spectrophotometric method PN-C-04576-4:1994
18 Water, Wastewater Nitrite nitrogen concentration
Range (0,002 – 10) mg/l
Spectrophotometric method PN-EN 26777:1999
19 Water, Wastewater Nitrate nitrogen concentration
Range (0,05 – 20) mg/l
Spectrophotometric method PN-82/C-04576.08
20 Water, Wastewater Total suspended solids (TSS)
Range (2,0 – 1000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
21 Water, Wastewater Sulfate concentration
Range (10 – 1000) mg/l
Gravimetric method PN-ISO 9280:2002
22 Water, Wastewater Chloride concentration
Range (5,0 – 2000) mg/l
Titrimetric method PN-ISO 9297:1994
23 Water, Wastewater Biochemical oxygen demand
BOD5 Range (1,0 – 6000) mg/l O2
Optical method PN ISO 5815-1:2019
24 Water, Wastewater Chemical oxygen demand
COD-Cr Range (30 – 7000) mg/l O2
Titrimetric method PN-ISO 6060:2006
25 Water, Wastewater Chemical oxygen demand
COD-Cr Range (5 – 700) mg/l O2
Titrimetric method PN-74/C-04578.03
26 Water, Wastewater Element concentrations,
Copper (0,003 – 0,400) mg/l Cadmium (0,0004 – 0,400) mg/l Chromium (0,002 – 20,0) mg/l Lead (0,0025 – 0,400) mg/l Nickel (0,007 – 0,500) mg/l
Electrothermal atomization atomic absorption spectrometry (ETAAS) PN-EN ISO 15586:2005
27 Water, Wastewater Element concentration
Sodium (0,10 – 400) mg/l Potassium (0,10 – 50,0) mg/l
Flame atomic emission spectrometry (FEAS) PN-ISO 9964-3:1994+Ak:1997
28 Water, Wastewater Zinc concentration
Range (0,05 – 40,0) mg/l
Flame atomic absorption spectrometry (FAAS) PN-ISO 8288:2002 metoda A
29 Water, Wastewater Element concentration
Iron (0,150 – 20,0) mg/l Manganese (0,030 – 10,0) mg/l
Flame atomic absorption spectrometry (FAAS) PN-92/C-04570/01
30 Water, Wastewater Mineral oil index
Range (0,1 – 50) mg/l
Gas chromatography with flame ionization detection (GC-FID) PN-EN ISO 9377-2:2003
31 Water, Wastewater Orthophosphate concentration
Range (0,02 – 20,0) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 p. 4 +Ap1:2010+Ap2:2010
32 Water, Wastewater Kjeldahl nitrogen concentration
Range (1,0 – 1000) mg/l
Titrimetric method PN-EN 25663:2001
33 Water, Wastewater Total nitrogen concentration (calculated) PB-22 wydanie I z dn. 01.09.2015 r.
34 Wastewater Total phosphorus concentration
Range (0,05 – 25,0) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 pkt 8 +Ap1:2010+Ap2:2010
35 Sewage sludge, Soils pH in H2O
Range 2,0 – 11,0
Potentiometric method PN-EN ISO 10390:2022

Reference standards (34)

ISO 17289:2014
PB-22 wydanie I z dn. 01.09.2015 r.
PB-24 wydanie 01 z dnia 10.10.2025 r.
PN EN ISO 7027-1:2006-09
PN ISO 5815-1:2019
PN-74/C-04578.03
PN-82/C-04576.08
PN-92/C-04570/01
PN-C-04554-4:1999
PN-C-04576-4:1994
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10390:2022
PN-EN ISO 10523:2012
PN-EN ISO 15586:2005
PN-EN ISO 19458:2007
PN-EN ISO 6878:2006 p. 4 +Ap1:2010+Ap2:2010
PN-EN ISO 6878:2006 pkt 7 +Ap1:2010+Ap2:2010
PN-EN ISO 6878:2006 pkt 8 +Ap1:2010+Ap2:2010
PN-EN ISO 7887:2012 + Ap1:2015-06 metoda C
PN-EN ISO 9377-2:2003
PN-ISO 5667-10:2021-11
PN-ISO 5667-11:2017-10
PN-ISO 5667-5:2017-10
PN-ISO 6058:1999
PN-ISO 6059:1999
PN-ISO 6060:2006
PN-ISO 7150-1:2002
PN-ISO 8288:2002 metoda A
PN-ISO 9280:2002
PN-ISO 9297:1994
PN-ISO 9964-3:1994+Ak:1997