🇵🇱 EKOSYSTEMY - JT JERZY TETERYCZ PL
Water & wastewater
EKOSYSTEMY - JT JERZY TETERYCZ is a laboratory accredited by PCA under number AB 1254 (Zielona Góra, Poland). Its accreditation scope covers 35 test methods in the following areas: Water & wastewater. Test objects include: Water, Wastewater, Water, Swimming pool water, Wastewater. Most frequently used techniques: Spectrophotometric method, Titrimetric method, Flame atomic absorption spectrometry (FAAS).
At a glance
- Accreditation number: PCA AB 1254
- Methods in scope: 35
- Types of test objects: 6
- Techniques used: 12
- City: Zielona Góra, Poland
- Accreditation number
- AB 1254
- Accreditation body
- PCA
- Address
- ul. Kożuchowska 10 e, 65-364 Zielona Góra
- City
- Zielona Góra, Poland
What this laboratory tests (6)
- Water, Wastewater — 19 methods
- Water — 9 methods
- Swimming pool water — 3 methods
- Wastewater — 2 methods
- Sewage sludge, Soils — 1 method
- Water intended for human consumption — 1 method
Analytical techniques used (12)
- Spectrophotometric method — 9 methods
- Titrimetric method — 6 methods
- Flame atomic absorption spectrometry (FAAS) — 3 methods
- Potentiometric method — 3 methods
- Gravimetric method — 2 methods
- Optical method — 2 methods
- Conductometric method — 1 method
- Electrothermal atomization atomic absorption spectrometry (ETAAS) — 1 method
- Flame atomic emission spectrometry (FEAS) — 1 method
- Gas chromatography with flame ionization detection (GC-FID) — 1 method
- Manual method; Automatic method — 1 method
- Nephelometric method — 1 method
Accreditation scope — test methods (35)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Water intended for human consumption | Sampling for physical, chemical and microbiological testing | PN-ISO 5667-5:2017-10 | PN-EN ISO 19458:2007 | ||
| 2 | Water | Sampling for physical and chemical testing | PN-ISO 5667-11:2017-10 | ||
| 3 | Wastewater | Sampling for physical and chemical testing Temperature Range (2,0 – 60,0)oC |
Manual method; Automatic method | PN-ISO 5667-10:2021-11 | PB-24 wydanie 01 z dnia 10.10.2025 r. | |
| 4 | Water | Total hardness (Total calcium and magnesium content) Range (2,5 – 1000) mg/l CaCO3 |
Titrimetric method | PN-ISO 6059:1999 | |
| 5 | Water | Calcium concentration Range (2,0 – 400) mg/l |
Titrimetric method | PN-ISO 6058:1999 | |
| 6 | Water | Magnesium concentration (calculated) | PN-C-04554-4:1999 | ||
| 7 | Water | Electrical conductivity Range (147 – 1413) μS/cm |
Conductometric method | PN-EN 27888:1999 | |
| 8 | Water | Total phosphorus concentration Range (0,05 - 25,0) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006 pkt 7 +Ap1:2010+Ap2:2010 | |
| 9 | Water | Turbidity Range (0,2– 20) NTU |
Nephelometric method | PN EN ISO 7027-1:2006-09 | |
| 10 | Water | Ammonium ion concentration Range (0,06 – 1,58) mg/l |
Spectrophotometric method | PN-ISO 7150-1:2002 | |
| 11 | Water | Colour Range (2 – 40) mg/l Pt |
Spectrophotometric method | PN-EN ISO 7887:2012 + Ap1:2015-06 metoda C | |
| 12 | Swimming pool water | pH Range 2,0 – 10,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 13 | Swimming pool water | Nitrate nitrogen concentration Range (0,05 – 20) mg/l |
Spectrophotometric method | PN-82/C-04576.08 | |
| 14 | Swimming pool water | Iron concentration Range (0,150 – 20,0) mg/l |
Flame atomic absorption spectrometry (FAAS) | PN-92/C-04570/01 | |
| 15 | Water, Wastewater | pH Range 2,0 – 10,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 16 | Water, Wastewater | Dissolved oxygen concentration Range (0,5 – 14) mg/l O2 |
Optical method | ISO 17289:2014 | |
| 17 | Water, Wastewater | Ammonium nitrogen concentration Range (0,25 – 100) mg/l |
Spectrophotometric method | PN-C-04576-4:1994 | |
| 18 | Water, Wastewater | Nitrite nitrogen concentration Range (0,002 – 10) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 19 | Water, Wastewater | Nitrate nitrogen concentration Range (0,05 – 20) mg/l |
Spectrophotometric method | PN-82/C-04576.08 | |
| 20 | Water, Wastewater | Total suspended solids (TSS) Range (2,0 – 1000) mg/l |
Gravimetric method | PN-EN 872:2007+Ap1:2007 | |
| 21 | Water, Wastewater | Sulfate concentration Range (10 – 1000) mg/l |
Gravimetric method | PN-ISO 9280:2002 | |
| 22 | Water, Wastewater | Chloride concentration Range (5,0 – 2000) mg/l |
Titrimetric method | PN-ISO 9297:1994 | |
| 23 | Water, Wastewater | Biochemical oxygen demand BOD5 Range (1,0 – 6000) mg/l O2 |
Optical method | PN ISO 5815-1:2019 | |
| 24 | Water, Wastewater | Chemical oxygen demand COD-Cr Range (30 – 7000) mg/l O2 |
Titrimetric method | PN-ISO 6060:2006 | |
| 25 | Water, Wastewater | Chemical oxygen demand COD-Cr Range (5 – 700) mg/l O2 |
Titrimetric method | PN-74/C-04578.03 | |
| 26 | Water, Wastewater | Element concentrations, Copper (0,003 – 0,400) mg/l Cadmium (0,0004 – 0,400) mg/l Chromium (0,002 – 20,0) mg/l Lead (0,0025 – 0,400) mg/l Nickel (0,007 – 0,500) mg/l |
Electrothermal atomization atomic absorption spectrometry (ETAAS) | PN-EN ISO 15586:2005 | |
| 27 | Water, Wastewater | Element concentration Sodium (0,10 – 400) mg/l Potassium (0,10 – 50,0) mg/l |
Flame atomic emission spectrometry (FEAS) | PN-ISO 9964-3:1994+Ak:1997 | |
| 28 | Water, Wastewater | Zinc concentration Range (0,05 – 40,0) mg/l |
Flame atomic absorption spectrometry (FAAS) | PN-ISO 8288:2002 metoda A | |
| 29 | Water, Wastewater | Element concentration Iron (0,150 – 20,0) mg/l Manganese (0,030 – 10,0) mg/l |
Flame atomic absorption spectrometry (FAAS) | PN-92/C-04570/01 | |
| 30 | Water, Wastewater | Mineral oil index Range (0,1 – 50) mg/l |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN ISO 9377-2:2003 | |
| 31 | Water, Wastewater | Orthophosphate concentration Range (0,02 – 20,0) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006 p. 4 +Ap1:2010+Ap2:2010 | |
| 32 | Water, Wastewater | Kjeldahl nitrogen concentration Range (1,0 – 1000) mg/l |
Titrimetric method | PN-EN 25663:2001 | |
| 33 | Water, Wastewater | Total nitrogen concentration (calculated) | PB-22 wydanie I z dn. 01.09.2015 r. | ||
| 34 | Wastewater | Total phosphorus concentration Range (0,05 – 25,0) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006 pkt 8 +Ap1:2010+Ap2:2010 | |
| 35 | Sewage sludge, Soils | pH in H2O Range 2,0 – 11,0 |
Potentiometric method | PN-EN ISO 10390:2022 | |
Reference standards (34)
ISO 17289:2014
PB-22 wydanie I z dn. 01.09.2015 r.
PB-24 wydanie 01 z dnia 10.10.2025 r.
PN EN ISO 7027-1:2006-09
PN ISO 5815-1:2019
PN-74/C-04578.03
PN-82/C-04576.08
PN-92/C-04570/01
PN-C-04554-4:1999
PN-C-04576-4:1994
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10390:2022
PN-EN ISO 10523:2012
PN-EN ISO 15586:2005
PN-EN ISO 19458:2007
PN-EN ISO 6878:2006 p. 4 +Ap1:2010+Ap2:2010
PN-EN ISO 6878:2006 pkt 7 +Ap1:2010+Ap2:2010
PN-EN ISO 6878:2006 pkt 8 +Ap1:2010+Ap2:2010
PN-EN ISO 7887:2012 + Ap1:2015-06 metoda C
PN-EN ISO 9377-2:2003
PN-ISO 5667-10:2021-11
PN-ISO 5667-11:2017-10
PN-ISO 5667-5:2017-10
PN-ISO 6058:1999
PN-ISO 6059:1999
PN-ISO 6060:2006
PN-ISO 7150-1:2002
PN-ISO 8288:2002 metoda A
PN-ISO 9280:2002
PN-ISO 9297:1994
PN-ISO 9964-3:1994+Ak:1997