{"lab":{"_id":"69ad52a3de79e566650fb66a","accr_number":"AB 1254","country":"PL","accr_body":"PCA","address":"ul. Kożuchowska 10 e, 65-364 Zielona Góra","categories":["water"],"city":"Zielona Góra","imported_at":"2026-03-08T10:42:43.265Z","methods_count":35,"name":"EKOSYSTEMY - JT JERZY TETERYCZ","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1254.pdf"],"scope_summary":"","search_text":"ekosystemy - jt jerzy teterycz ul. kożuchowska 10 e, 65-364 zielona góra water microbiology other pharma electronics food","status":"active","updated_at":"2026-03-08T14:50:25.623Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T07:58:55.985Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201254,podmiot.html","parse_date":"2026-08-13T07:58:55.985Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"C/28/P; C/29/P, C30/P","pl":"Badania chemiczne i pobieranie próbek wody, ścieków, wody przeznaczonej do spożycia przez ludzi","en":"Chemical tests and sampling of water, sewage, drinking water"},{"codes":"N/28/P; N/29/P, N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, ścieków, wody przeznaczonej do spożycia przez ludzi","en":"Tests of physical properties and sampling of water, sewage, drinking water"},{"codes":"N//31, N/32","pl":"Badania właściwości fizycznych gleb, osadów ściekowych","en":"Tests of physical properties of soil, sediments"},{"codes":"P/29","pl":"Pobieranie próbek wody do spożycia przez ludzi do badań mikrobiologicznych","en":"Sampling of drinking water for microbiological tests"}],"issue":{"no":"15","date":"21.01.2026"},"map_coord":[51.925261,15.508256],"map_geo":"nominatim-street","scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/2e3a58bf0726386904cc32f193884195/AB%201254.pdf","has_en":true,"category_counts":{"water":35,"petro":1,"microbiology":1,"materials":1},"category_scores":{"water":32.24,"petro":0.03,"microbiology":0.03,"materials":0.03},"has_zh":true},"methods":[{"_id":"6a7d79400636ba417e41a816","lab_id":"69ad52a3de79e566650fb66a","country":"PL","accr_number":"AB 1254","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań fizycznych, chemicznych i mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań fizycznych, chemicznych i mikrobiologicznych","reference":"PN-ISO 5667-5:2017-10 | PN-EN ISO 19458:2007","norm_bases":["PN-ISO 5667-5:2017-10","PN-EN ISO 19458:2007"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań fizycznych, chemicznych i mikrobiologicznych PN-ISO 5667-5:2017-10 | PN-EN ISO 19458:2007 Woda do spozycia przez ludzi Pobieranie probek do badan fizycznych, chemicznych i mikrobiologicznych PN-ISO 5667-5:2017-10 | PN-EN ISO 19458:2007","categories":["water","microbiology"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for physical, chemical and microbiological testing","search_en":"Water intended for human consumption Sampling for physical, chemical and microbiological testing PN-ISO 5667-5:2017-10 | PN-EN ISO 19458:2007","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 PN-ISO 5667-5:2017-10 | PN-EN ISO 19458:2007","test_object_zh":"生活饮用水"},{"_id":"6a7d79400636ba417e41a817","lab_id":"69ad52a3de79e566650fb66a","country":"PL","accr_number":"AB 1254","accr_body":"PCA","test_object":"Woda","methodology":"Pobieranie próbek do badań fizycznych i chemicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań fizycznych i chemicznych","reference":"PN-ISO 5667-11:2017-10","norm_bases":["PN-ISO 5667-11:2017-10"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Pobieranie próbek do badań fizycznych i chemicznych PN-ISO 5667-11:2017-10 Woda Pobieranie probek do badan fizycznych i chemicznych PN-ISO 5667-11:2017-10","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for physical and chemical testing","search_en":"Water Sampling for physical and chemical testing PN-ISO 5667-11:2017-10","test_object_en":"Water","methodology_zh":"物理与化学检测用样品采集","search_zh":"水 物理与化学检测用样品采集 PN-ISO 5667-11:2017-10","test_object_zh":"水"},{"_id":"6a7d79400636ba417e41a818","lab_id":"69ad52a3de79e566650fb66a","country":"PL","accr_number":"AB 1254","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań fizycznych i chemicznych","parameters":[{"name":"Temperatura"},{"name":"Zakres","range":"(2,0 – 60,0)oC"}],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań fizycznych i chemicznych\nZakres:\nTemperatura\nZakres (2,0 – 60,0)oC\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11 | PB-24 wydanie 01 z dnia 10.10.2025 r.","norm_bases":["PN-ISO 5667-10:2021-11","PB-24 wydanie 01 z dnia 10.10.2025 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań fizycznych i chemicznych\nZakres:\nTemperatura\nZakres (2,0 – 60,0)oC\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 | PB-24 wydanie 01 z dnia 10.10.2025 r. Scieki Pobieranie probek do badan fizycznych i chemicznych\nZakres:\nTemperatura\nZakres (2,0 – 60,0)oC\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 | PB-24 wydanie 01 z dnia 10.10.2025 r.","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for physical and chemical testing","parameters_en":[{"name":"Temperature"},{"name":"Range","range":"(2,0 – 60,0)oC"}],"search_en":"Wastewater Sampling for physical and chemical testing Manual method; Automatic method Temperature Range PN-ISO 5667-10:2021-11 | PB-24 wydanie 01 z dnia 10.10.2025 r.","technique_en":"Manual method; Automatic method","test_object_en":"Wastewater","methodology_zh":"物理与化学检测用样品采集","parameters_zh":[{"name":"温度"},{"name":"范围","range":"(2,0 – 60,0)oC"}],"search_zh":"污水 物理与化学检测用样品采集 手动法；自动法 温度 范围 PN-ISO 5667-10:2021-11 | PB-24 wydanie 01 z dnia 10.10.2025 r.","technique_zh":"手动法；自动法","test_object_zh":"污水"},{"_id":"6a7d79400636ba417e41a819","lab_id":"69ad52a3de79e566650fb66a","country":"PL","accr_number":"AB 1254","accr_body":"PCA","test_object":"Woda","methodology":"Twardość ogólna (Sumaryczna zawartość wapnia i magnezu)","parameters":[{"name":"Zakres","range":"(2,5 – 1000) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Twardość ogólna (Sumaryczna zawartość wapnia i magnezu)\nZakres (2,5 – 1000) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Twardość ogólna (Sumaryczna zawartość wapnia i magnezu)\nZakres (2,5 – 1000) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda Twardosc ogolna (Sumaryczna zawartosc wapnia i magnezu)\nZakres (2,5 – 1000) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total hardness (Total calcium and magnesium content)","parameters_en":[{"name":"Range","range":"(2,5 – 1000) mg/l CaCO3"}],"search_en":"Water Total hardness (Total calcium and magnesium content) Titrimetric method Range PN-ISO 6059:1999","technique_en":"Titrimetric method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(2,5 – 1000) mg/l CaCO3"}],"search_zh":"水 滴定法 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水"},{"_id":"6a7d79400636ba417e41a81a","lab_id":"69ad52a3de79e566650fb66a","country":"PL","accr_number":"AB 1254","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie wapnia","parameters":[{"name":"Zakres","range":"(2,0 – 400) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie wapnia\nZakres (2,0 – 400) mg/l\nMetoda miareczkowa","reference":"PN-ISO 6058:1999","norm_bases":["PN-ISO 6058:1999"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie wapnia\nZakres (2,0 – 400) mg/l\nMetoda miareczkowa PN-ISO 6058:1999 Woda Stezenie wapnia\nZakres (2,0 – 400) mg/l\nMetoda miareczkowa PN-ISO 6058:1999","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Calcium concentration","parameters_en":[{"name":"Range","range":"(2,0 – 400) mg/l"}],"search_en":"Water Calcium concentration Titrimetric method Range PN-ISO 6058:1999","technique_en":"Titrimetric method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(2,0 – 400) mg/l"}],"search_zh":"水 钙浓度 滴定法 范围 PN-ISO 6058:1999","technique_zh":"滴定法","test_object_zh":"水","methodology_zh":"钙浓度"},{"_id":"6a7d79400636ba417e41a81b","lab_id":"69ad52a3de79e566650fb66a","country":"PL","accr_number":"AB 1254","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie magnezu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie magnezu (z obliczeń)","reference":"PN-C-04554-4:1999","norm_bases":["PN-C-04554-4:1999"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie magnezu (z obliczeń) PN-C-04554-4:1999 Woda Stezenie magnezu (z obliczen) PN-C-04554-4:1999","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnesium concentration (calculated)","search_en":"Water Magnesium concentration (calculated) PN-C-04554-4:1999","test_object_en":"Water","search_zh":"水 镁浓度（计算值） PN-C-04554-4:1999","test_object_zh":"水","methodology_zh":"镁浓度（计算值）"},{"_id":"6a7d79400636ba417e41a81c","lab_id":"69ad52a3de79e566650fb66a","country":"PL","accr_number":"AB 1254","accr_body":"PCA","test_object":"Woda","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(147 – 1413) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (147 – 1413) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Przewodność elektryczna właściwa\nZakres (147 – 1413) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda Przewodnosc elektryczna wlasciwa\nZakres (147 – 1413) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(147 – 1413) μS/cm"}],"search_en":"Water Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(147 – 1413) μS/cm"}],"search_zh":"水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水"},{"_id":"6a7d79400636ba417e41a81d","lab_id":"69ad52a3de79e566650fb66a","country":"PL","accr_number":"AB 1254","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,05 - 25,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,05 - 25,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt 7 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt 7 +Ap1:2010+Ap2:2010"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie fosforu ogólnego\nZakres (0,05 - 25,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 7 +Ap1:2010+Ap2:2010 Woda Stezenie fosforu ogolnego\nZakres (0,05 - 25,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 7 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,05 - 25,0) mg/l"}],"search_en":"Water Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006 pkt 7 +Ap1:2010+Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,05 - 25,0) mg/l"}],"search_zh":"水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006 pkt 7 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a7d79400636ba417e41a81e","lab_id":"69ad52a3de79e566650fb66a","country":"PL","accr_number":"AB 1254","accr_body":"PCA","test_object":"Woda","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,2– 20) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,2– 20) NTU\nMetoda nefelometryczna","reference":"PN EN ISO 7027-1:2006-09","norm_bases":["PN EN ISO 7027-1:2006-09"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Mętność\nZakres (0,2– 20) NTU\nMetoda nefelometryczna PN EN ISO 7027-1:2006-09 Woda Metnosc\nZakres (0,2– 20) NTU\nMetoda nefelometryczna PN EN ISO 7027-1:2006-09","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,2– 20) NTU"}],"search_en":"Water Turbidity Nephelometric method Range PN EN ISO 7027-1:2006-09","technique_en":"Nephelometric method","test_object_en":"Water","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,2– 20) NTU"}],"search_zh":"水 浊度 浊度法（散射法） 范围 PN EN ISO 7027-1:2006-09","technique_zh":"浊度法（散射法）","test_object_zh":"水"},{"_id":"6a7d79400636ba417e41a81f","lab_id":"69ad52a3de79e566650fb66a","country":"PL","accr_number":"AB 1254","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie jonu amonowego","parameters":[{"name":"Zakres","range":"(0,06 – 1,58) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonu amonowego\nZakres (0,06 – 1,58) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie jonu amonowego\nZakres (0,06 – 1,58) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda Stezenie jonu amonowego\nZakres (0,06 – 1,58) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium ion concentration","parameters_en":[{"name":"Range","range":"(0,06 – 1,58) mg/l"}],"search_en":"Water Ammonium ion concentration Spectrophotometric method Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,06 – 1,58) mg/l"}],"search_zh":"水 铵离子浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a7d79400636ba417e41a820","lab_id":"69ad52a3de79e566650fb66a","country":"PL","accr_number":"AB 1254","accr_body":"PCA","test_object":"Woda","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(2 – 40) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa\nZakres (2 – 40) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 + Ap1:2015-06 metoda C","norm_bases":["PN-EN ISO 7887:2012 + Ap1:2015-06 metoda C"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Barwa\nZakres (2 – 40) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 + Ap1:2015-06 metoda C Woda Barwa\nZakres (2 – 40) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 + Ap1:2015-06 metoda C","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(2 – 40) mg/l Pt"}],"search_en":"Water Colour Spectrophotometric method Range PN-EN ISO 7887:2012 + Ap1:2015-06 metoda C","technique_en":"Spectrophotometric method","test_object_en":"Water","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(2 – 40) mg/l Pt"}],"search_zh":"水 色度 分光光度法 范围 PN-EN ISO 7887:2012 + Ap1:2015-06 metoda C","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a7d79400636ba417e41a821","lab_id":"69ad52a3de79e566650fb66a","country":"PL","accr_number":"AB 1254","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda na plywalniach pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 10,0"}],"search_en":"Swimming pool water pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Swimming pool water","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 10,0"}],"search_zh":"游泳池水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"游泳池水"},{"_id":"6a7d79400636ba417e41a822","lab_id":"69ad52a3de79e566650fb66a","country":"PL","accr_number":"AB 1254","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,05 – 20) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (0,05 – 20) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Stężenie azotu azotanowego\nZakres (0,05 – 20) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08 Woda na plywalniach Stezenie azotu azotanowego\nZakres (0,05 – 20) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,05 – 20) mg/l"}],"search_en":"Swimming pool water Nitrate nitrogen concentration Spectrophotometric method Range PN-82/C-04576.08","technique_en":"Spectrophotometric method","test_object_en":"Swimming pool water","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 20) mg/l"}],"search_zh":"游泳池水 硝态氮浓度 分光光度法 范围 PN-82/C-04576.08","technique_zh":"分光光度法","test_object_zh":"游泳池水"},{"_id":"6a7d79400636ba417e41a823","lab_id":"69ad52a3de79e566650fb66a","country":"PL","accr_number":"AB 1254","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Stężenie żelaza","parameters":[{"name":"Zakres","range":"(0,150 – 20,0) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie żelaza\nZakres (0,150 – 20,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-92/C-04570/01","norm_bases":["PN-92/C-04570/01"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Stężenie żelaza\nZakres (0,150 – 20,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-92/C-04570/01 Woda na plywalniach Stezenie zelaza\nZakres (0,150 – 20,0) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-92/C-04570/01","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Iron concentration","parameters_en":[{"name":"Range","range":"(0,150 – 20,0) mg/l"}],"search_en":"Swimming pool water Iron concentration Flame atomic absorption spectrometry (FAAS) Range PN-92/C-04570/01","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Swimming pool water","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(0,150 – 20,0) mg/l"}],"search_zh":"游泳池水 铁浓度 火焰原子吸收光谱法（FAAS） 范围 PN-92/C-04570/01","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"游泳池水"},{"_id":"6a7d79400636ba417e41a824","lab_id":"69ad52a3de79e566650fb66a","country":"PL","accr_number":"AB 1254","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, Scieki pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 10,0"}],"search_en":"Water, Wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, Wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 10,0"}],"search_zh":"水、污水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、污水"},{"_id":"6a7d79400636ba417e41a825","lab_id":"69ad52a3de79e566650fb66a","country":"PL","accr_number":"AB 1254","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie tlenu rozpuszczonego","parameters":[{"name":"Zakres","range":"(0,5 – 14) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Stężenie tlenu rozpuszczonego\nZakres (0,5 – 14) mg/l O2\nMetoda optyczna","reference":"ISO 17289:2014","norm_bases":["ISO 17289:2014"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie tlenu rozpuszczonego\nZakres (0,5 – 14) mg/l O2\nMetoda optyczna ISO 17289:2014 Woda, Scieki Stezenie tlenu rozpuszczonego\nZakres (0,5 – 14) mg/l O2\nMetoda optyczna ISO 17289:2014","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved oxygen concentration","parameters_en":[{"name":"Range","range":"(0,5 – 14) mg/l O2"}],"search_en":"Water, Wastewater Dissolved oxygen concentration Optical method Range ISO 17289:2014","technique_en":"Optical method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(0,5 – 14) mg/l O2"}],"search_zh":"水、污水 溶解氧浓度 光学法 范围 ISO 17289:2014","technique_zh":"光学法","test_object_zh":"水、污水","methodology_zh":"溶解氧浓度"},{"_id":"6a7d79400636ba417e41a826","lab_id":"69ad52a3de79e566650fb66a","country":"PL","accr_number":"AB 1254","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,25 – 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,25 – 100) mg/l\nMetoda spektrofotometryczna","reference":"PN-C-04576-4:1994","norm_bases":["PN-C-04576-4:1994"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu amonowego\nZakres (0,25 – 100) mg/l\nMetoda spektrofotometryczna PN-C-04576-4:1994 Woda, Scieki Stezenie azotu amonowego\nZakres (0,25 – 100) mg/l\nMetoda spektrofotometryczna PN-C-04576-4:1994","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,25 – 100) mg/l"}],"search_en":"Water, Wastewater Ammonium nitrogen concentration Spectrophotometric method Range PN-C-04576-4:1994","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,25 – 100) mg/l"}],"search_zh":"水、污水 氨氮浓度 分光光度法 范围 PN-C-04576-4:1994","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a7d79400636ba417e41a827","lab_id":"69ad52a3de79e566650fb66a","country":"PL","accr_number":"AB 1254","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,002 – 10) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,002 – 10) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu azotynowego\nZakres (0,002 – 10) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, Scieki Stezenie azotu azotynowego\nZakres (0,002 – 10) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,002 – 10) mg/l"}],"search_en":"Water, Wastewater Nitrite nitrogen concentration Spectrophotometric method Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,002 – 10) mg/l"}],"search_zh":"水、污水 亚硝态氮浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a7d79400636ba417e41a828","lab_id":"69ad52a3de79e566650fb66a","country":"PL","accr_number":"AB 1254","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,05 – 20) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (0,05 – 20) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu azotanowego\nZakres (0,05 – 20) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08 Woda, Scieki Stezenie azotu azotanowego\nZakres (0,05 – 20) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,05 – 20) mg/l"}],"search_en":"Water, Wastewater Nitrate nitrogen concentration Spectrophotometric method Range PN-82/C-04576.08","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 20) mg/l"}],"search_zh":"水、污水 硝态氮浓度 分光光度法 范围 PN-82/C-04576.08","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a7d79400636ba417e41a829","lab_id":"69ad52a3de79e566650fb66a","country":"PL","accr_number":"AB 1254","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Zawiesiny ogólne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, Scieki Zawiesiny ogolne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 1000) mg/l"}],"search_en":"Water, Wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, Wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 1000) mg/l"}],"search_zh":"水、污水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、污水"},{"_id":"6a7d79400636ba417e41a82a","lab_id":"69ad52a3de79e566650fb66a","country":"PL","accr_number":"AB 1254","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(10 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie siarczanów\nZakres (10 – 1000) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie siarczanów\nZakres (10 – 1000) mg/l\nMetoda wagowa PN-ISO 9280:2002 Woda, Scieki Stezenie siarczanow\nZakres (10 – 1000) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(10 – 1000) mg/l"}],"search_en":"Water, Wastewater Sulfate concentration Gravimetric method Range PN-ISO 9280:2002","technique_en":"Gravimetric method","test_object_en":"Water, Wastewater","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10 – 1000) mg/l"}],"search_zh":"水、污水 硫酸盐浓度 重量法 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"水、污水"},{"_id":"6a7d79400636ba417e41a82b","lab_id":"69ad52a3de79e566650fb66a","country":"PL","accr_number":"AB 1254","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,0 – 2000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,0 – 2000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie chlorków\nZakres (5,0 – 2000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, Scieki Stezenie chlorkow\nZakres (5,0 – 2000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,0 – 2000) mg/l"}],"search_en":"Water, Wastewater Chloride concentration Titrimetric method Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water, Wastewater","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 2000) mg/l"}],"search_zh":"水、污水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、污水"},{"_id":"6a7d79400636ba417e41a82c","lab_id":"69ad52a3de79e566650fb66a","country":"PL","accr_number":"AB 1254","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(1,0 – 6000) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1,0 – 6000) mg/l O2\nMetoda optyczna","reference":"PN ISO 5815-1:2019","norm_bases":["PN ISO 5815-1:2019"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1,0 – 6000) mg/l O2\nMetoda optyczna PN ISO 5815-1:2019 Woda, Scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1,0 – 6000) mg/l O2\nMetoda optyczna PN ISO 5815-1:2019","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(1,0 – 6000) mg/l O2"}],"search_en":"Water, Wastewater Biochemical oxygen demand Optical method BOD5 Range PN ISO 5815-1:2019","technique_en":"Optical method","test_object_en":"Water, Wastewater","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(1,0 – 6000) mg/l O2"}],"search_zh":"水、污水 生化需氧量 光学法 BZT5（BOD5） 范围 PN ISO 5815-1:2019","technique_zh":"光学法","test_object_zh":"水、污水"},{"_id":"6a7d79400636ba417e41a82d","lab_id":"69ad52a3de79e566650fb66a","country":"PL","accr_number":"AB 1254","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu","parameters":[{"name":"ChZT-Cr"},{"name":"Zakres","range":"(30 – 7000) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (30 – 7000) mg/l O2\nMetoda miareczkowa","reference":"PN-ISO 6060:2006","norm_bases":["PN-ISO 6060:2006"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (30 – 7000) mg/l O2\nMetoda miareczkowa PN-ISO 6060:2006 Woda, Scieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (30 – 7000) mg/l O2\nMetoda miareczkowa PN-ISO 6060:2006","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand","parameters_en":[{"name":"COD-Cr"},{"name":"Range","range":"(30 – 7000) mg/l O2"}],"search_en":"Water, Wastewater Chemical oxygen demand Titrimetric method COD-Cr Range PN-ISO 6060:2006","technique_en":"Titrimetric method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"化学需氧量（COD-Cr）"},{"name":"范围","range":"(30 – 7000) mg/l O2"}],"search_zh":"水、污水 化学需氧量（COD） 滴定法 化学需氧量（COD-Cr） 范围 PN-ISO 6060:2006","technique_zh":"滴定法","test_object_zh":"水、污水","methodology_zh":"化学需氧量（COD）"},{"_id":"6a7d79400636ba417e41a82e","lab_id":"69ad52a3de79e566650fb66a","country":"PL","accr_number":"AB 1254","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu","parameters":[{"name":"ChZT-Cr"},{"name":"Zakres","range":"(5 – 700) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (5 – 700) mg/l O2\nMetoda miareczkowa","reference":"PN-74/C-04578.03","norm_bases":["PN-74/C-04578.03"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (5 – 700) mg/l O2\nMetoda miareczkowa PN-74/C-04578.03 Woda, Scieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (5 – 700) mg/l O2\nMetoda miareczkowa PN-74/C-04578.03","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand","parameters_en":[{"name":"COD-Cr"},{"name":"Range","range":"(5 – 700) mg/l O2"}],"search_en":"Water, Wastewater Chemical oxygen demand Titrimetric method COD-Cr Range PN-74/C-04578.03","technique_en":"Titrimetric method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"化学需氧量（COD-Cr）"},{"name":"范围","range":"(5 – 700) mg/l O2"}],"search_zh":"水、污水 化学需氧量（COD） 滴定法 化学需氧量（COD-Cr） 范围 PN-74/C-04578.03","technique_zh":"滴定法","test_object_zh":"水、污水","methodology_zh":"化学需氧量（COD）"},{"_id":"6a7d79400636ba417e41a82f","lab_id":"69ad52a3de79e566650fb66a","country":"PL","accr_number":"AB 1254","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie pierwiastków,","parameters":[{"name":"Miedź","range":"(0,003 – 0,400) mg/l"},{"name":"Kadm","range":"(0,0004 – 0,400) mg/l"},{"name":"Chrom","range":"(0,002 – 20,0) mg/l"},{"name":"Ołów","range":"(0,0025 – 0,400) mg/l"},{"name":"Nikiel","range":"(0,007 – 0,500) mg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)"],"computed":[],"activity":"Stężenie pierwiastków,\nZakres:\nMiedź (0,003 – 0,400) mg/l\nKadm (0,0004 – 0,400) mg/l\nChrom (0,002 – 20,0) mg/l\nOłów (0,0025 – 0,400) mg/l\nNikiel (0,007 – 0,500) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","reference":"PN-EN ISO 15586:2005","norm_bases":["PN-EN ISO 15586:2005"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie pierwiastków,\nZakres:\nMiedź (0,003 – 0,400) mg/l\nKadm (0,0004 – 0,400) mg/l\nChrom (0,002 – 20,0) mg/l\nOłów (0,0025 – 0,400) mg/l\nNikiel (0,007 – 0,500) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS) PN-EN ISO 15586:2005 Woda, Scieki Stezenie pierwiastkow,\nZakres:\nMiedz (0,003 – 0,400) mg/l\nKadm (0,0004 – 0,400) mg/l\nChrom (0,002 – 20,0) mg/l\nOlow (0,0025 – 0,400) mg/l\nNikiel (0,007 – 0,500) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacja elektrotermiczna (ETAAS) PN-EN ISO 15586:2005","categories":["water","materials"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element concentrations,","parameters_en":[{"name":"Copper","range":"(0,003 – 0,400) mg/l"},{"name":"Cadmium","range":"(0,0004 – 0,400) mg/l"},{"name":"Chromium","range":"(0,002 – 20,0) mg/l"},{"name":"Lead","range":"(0,0025 – 0,400) mg/l"},{"name":"Nickel","range":"(0,007 – 0,500) mg/l"}],"search_en":"Water, Wastewater Element concentrations, Electrothermal atomization atomic absorption spectrometry (ETAAS) Copper Cadmium Chromium Lead Nickel PN-EN ISO 15586:2005","technique_en":"Electrothermal atomization atomic absorption spectrometry (ETAAS)","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"铜","range":"(0,003 – 0,400) mg/l"},{"name":"镉","range":"(0,0004 – 0,400) mg/l"},{"name":"铬","range":"(0,002 – 20,0) mg/l"},{"name":"铅","range":"(0,0025 – 0,400) mg/l"},{"name":"镍","range":"(0,007 – 0,500) mg/l"}],"search_zh":"水、污水 电热原子化原子吸收光谱法（ETAAS） 铜 镉 铬 铅 镍 PN-EN ISO 15586:2005","technique_zh":"电热原子化原子吸收光谱法（ETAAS）","test_object_zh":"水、污水"},{"_id":"6a7d79400636ba417e41a830","lab_id":"69ad52a3de79e566650fb66a","country":"PL","accr_number":"AB 1254","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie pierwiastków","parameters":[{"name":"Sód","range":"(0,10 – 400) mg/l"},{"name":"Potas","range":"(0,10 – 50,0) mg/l"}],"technique":"Metoda płomieniowej emisyjnej spektrometrii atomowej (FEAS)","techniques":["Metoda płomieniowej emisyjnej spektrometrii atomowej (FEAS)"],"computed":[],"activity":"Stężenie pierwiastków\nZakres:\nSód (0,10 – 400) mg/l\nPotas (0,10 – 50,0) mg/l\nMetoda płomieniowej emisyjnej spektrometrii atomowej (FEAS)","reference":"PN-ISO 9964-3:1994+Ak:1997","norm_bases":["PN-ISO 9964-3:1994+Ak:1997"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie pierwiastków\nZakres:\nSód (0,10 – 400) mg/l\nPotas (0,10 – 50,0) mg/l\nMetoda płomieniowej emisyjnej spektrometrii atomowej (FEAS) PN-ISO 9964-3:1994+Ak:1997 Woda, Scieki Stezenie pierwiastkow\nZakres:\nSod (0,10 – 400) mg/l\nPotas (0,10 – 50,0) mg/l\nMetoda plomieniowej emisyjnej spektrometrii atomowej (FEAS) PN-ISO 9964-3:1994+Ak:1997","categories":["water"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element concentration","parameters_en":[{"name":"Sodium","range":"(0,10 – 400) mg/l"},{"name":"Potassium","range":"(0,10 – 50,0) mg/l"}],"search_en":"Water, Wastewater Element concentration Flame atomic emission spectrometry (FEAS) Sodium Potassium PN-ISO 9964-3:1994+Ak:1997","technique_en":"Flame atomic emission spectrometry (FEAS)","test_object_en":"Water, Wastewater","methodology_zh":"元素浓度","search_zh":"水、污水 元素浓度 火焰原子发射光谱法（FEAS） 钠 钾 PN-ISO 9964-3:1994+Ak:1997","test_object_zh":"水、污水","parameters_zh":[{"name":"钠","range":"(0,10 – 400) mg/l"},{"name":"钾","range":"(0,10 – 50,0) mg/l"}],"technique_zh":"火焰原子发射光谱法（FEAS）"},{"_id":"6a7d79400636ba417e41a831","lab_id":"69ad52a3de79e566650fb66a","country":"PL","accr_number":"AB 1254","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie cynku","parameters":[{"name":"Zakres","range":"(0,05 – 40,0) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie cynku\nZakres (0,05 – 40,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 8288:2002 metoda A","norm_bases":["PN-ISO 8288:2002 metoda A"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie cynku\nZakres (0,05 – 40,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 metoda A Woda, Scieki Stezenie cynku\nZakres (0,05 – 40,0) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 metoda A","categories":["water"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Zinc concentration","parameters_en":[{"name":"Range","range":"(0,05 – 40,0) mg/l"}],"search_en":"Water, Wastewater Zinc concentration Flame atomic absorption spectrometry (FAAS) Range PN-ISO 8288:2002 metoda A","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(0,05 – 40,0) mg/l"}],"search_zh":"水、污水 锌浓度 火焰原子吸收光谱法（FAAS） 范围 PN-ISO 8288:2002 metoda A","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水、污水","methodology_zh":"锌浓度"},{"_id":"6a7d79400636ba417e41a832","lab_id":"69ad52a3de79e566650fb66a","country":"PL","accr_number":"AB 1254","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie pierwiastków","parameters":[{"name":"Żelazo","range":"(0,150 – 20,0) mg/l"},{"name":"Mangan","range":"(0,030 – 10,0) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie pierwiastków\nZakres:\nŻelazo (0,150 – 20,0) mg/l\nMangan (0,030 – 10,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-92/C-04570/01","norm_bases":["PN-92/C-04570/01"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie pierwiastków\nZakres:\nŻelazo (0,150 – 20,0) mg/l\nMangan (0,030 – 10,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-92/C-04570/01 Woda, Scieki Stezenie pierwiastkow\nZakres:\nZelazo (0,150 – 20,0) mg/l\nMangan (0,030 – 10,0) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-92/C-04570/01","categories":["water"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element concentration","parameters_en":[{"name":"Iron","range":"(0,150 – 20,0) mg/l"},{"name":"Manganese","range":"(0,030 – 10,0) mg/l"}],"search_en":"Water, Wastewater Element concentration Flame atomic absorption spectrometry (FAAS) Iron Manganese PN-92/C-04570/01","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Water, Wastewater","methodology_zh":"元素浓度","search_zh":"水、污水 元素浓度 火焰原子吸收光谱法（FAAS） 铁 锰 PN-92/C-04570/01","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水、污水","parameters_zh":[{"name":"铁","range":"(0,150 – 20,0) mg/l"},{"name":"锰","range":"(0,030 – 10,0) mg/l"}]},{"_id":"6a7d79400636ba417e41a833","lab_id":"69ad52a3de79e566650fb66a","country":"PL","accr_number":"AB 1254","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Indeks oleju mineralnego","parameters":[{"name":"Zakres","range":"(0,1 – 50) mg/l"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Indeks oleju mineralnego\nZakres (0,1 – 50) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 9377-2:2003","norm_bases":["PN-EN ISO 9377-2:2003"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Indeks oleju mineralnego\nZakres (0,1 – 50) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 9377-2:2003 Woda, Scieki Indeks oleju mineralnego\nZakres (0,1 – 50) mg/l\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 9377-2:2003","categories":["water","petro"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mineral oil index","parameters_en":[{"name":"Range","range":"(0,1 – 50) mg/l"}],"search_en":"Water, Wastewater Mineral oil index Gas chromatography with flame ionization detection (GC-FID) Range PN-EN ISO 9377-2:2003","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(0,1 – 50) mg/l"}],"search_zh":"水、污水 矿物油指数 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN ISO 9377-2:2003","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"水、污水","methodology_zh":"矿物油指数"},{"_id":"6a7d79400636ba417e41a834","lab_id":"69ad52a3de79e566650fb66a","country":"PL","accr_number":"AB 1254","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie ortofosforanów","parameters":[{"name":"Zakres","range":"(0,02 – 20,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie ortofosforanów\nZakres (0,02 – 20,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 p. 4 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 p. 4 +Ap1:2010+Ap2:2010"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie ortofosforanów\nZakres (0,02 – 20,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p. 4 +Ap1:2010+Ap2:2010 Woda, Scieki Stezenie ortofosforanow\nZakres (0,02 – 20,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p. 4 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Orthophosphate concentration","parameters_en":[{"name":"Range","range":"(0,02 – 20,0) mg/l"}],"search_en":"Water, Wastewater Orthophosphate concentration Spectrophotometric method Range PN-EN ISO 6878:2006 p. 4 +Ap1:2010+Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(0,02 – 20,0) mg/l"}],"search_zh":"水、污水 正磷酸盐浓度 分光光度法 范围 PN-EN ISO 6878:2006 p. 4 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、污水","methodology_zh":"正磷酸盐浓度"},{"_id":"6a7d79400636ba417e41a835","lab_id":"69ad52a3de79e566650fb66a","country":"PL","accr_number":"AB 1254","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(1,0 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (1,0 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu Kjeldahla\nZakres (1,0 – 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Woda, Scieki Stezenie azotu Kjeldahla\nZakres (1,0 – 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(1,0 – 1000) mg/l"}],"search_en":"Water, Wastewater Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Water, Wastewater","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(1,0 – 1000) mg/l"}],"search_zh":"水、污水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"水、污水"},{"_id":"6a7d79400636ba417e41a836","lab_id":"69ad52a3de79e566650fb66a","country":"PL","accr_number":"AB 1254","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu ogólnego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PB-22 wydanie I z dn. 01.09.2015 r.","norm_bases":["PB-22 wydanie I z dn. 01.09.2015 r."],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu ogólnego (z obliczeń) PB-22 wydanie I z dn. 01.09.2015 r. Woda, Scieki Stezenie azotu ogolnego (z obliczen) PB-22 wydanie I z dn. 01.09.2015 r.","categories":["water"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration (calculated)","search_en":"Water, Wastewater Total nitrogen concentration (calculated) PB-22 wydanie I z dn. 01.09.2015 r.","test_object_en":"Water, Wastewater","methodology_zh":"总氮浓度（计算值）","search_zh":"水、污水 总氮浓度（计算值） PB-22 wydanie I z dn. 01.09.2015 r.","test_object_zh":"水、污水"},{"_id":"6a7d79400636ba417e41a837","lab_id":"69ad52a3de79e566650fb66a","country":"PL","accr_number":"AB 1254","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,05 – 25,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,05 – 25,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt 8 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt 8 +Ap1:2010+Ap2:2010"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie fosforu ogólnego\nZakres (0,05 – 25,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 8 +Ap1:2010+Ap2:2010 Scieki Stezenie fosforu ogolnego\nZakres (0,05 – 25,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 8 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,05 – 25,0) mg/l"}],"search_en":"Wastewater Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006 pkt 8 +Ap1:2010+Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 25,0) mg/l"}],"search_zh":"污水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006 pkt 8 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a7d79400636ba417e41a838","lab_id":"69ad52a3de79e566650fb66a","country":"PL","accr_number":"AB 1254","accr_body":"PCA","test_object":"Osady ściekowe, Gleby","methodology":"pH w H2O","parameters":[{"name":"Zakres","range":"2,0 – 11,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH w H2O\nZakres 2,0 – 11,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022","norm_bases":["PN-EN ISO 10390:2022"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe, Gleby pH w H2O\nZakres 2,0 – 11,0\nMetoda potencjometryczna PN-EN ISO 10390:2022 Osady sciekowe, Gleby pH w H2O\nZakres 2,0 – 11,0\nMetoda potencjometryczna PN-EN ISO 10390:2022","categories":["water"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH in H2O","parameters_en":[{"name":"Range","range":"2,0 – 11,0"}],"search_en":"Sewage sludge, Soils pH in H2O Potentiometric method Range PN-EN ISO 10390:2022","technique_en":"Potentiometric method","test_object_en":"Sewage sludge, Soils","methodology_zh":"水中 pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 11,0"}],"search_zh":"水中 pH 值 电位法 范围 PN-EN ISO 10390:2022","technique_zh":"电位法"}],"has_pdf":true}