🇵🇱 DOROTA PRZĄDO DM PL

PCA AB 1249 • Wrocław, Poland • 29 methods

Water & wastewaterEnvironmentMaterials & polymersPetrochemistry & fuels

DOROTA PRZĄDO DM is a laboratory accredited by PCA under number AB 1249 (Wrocław, Poland). Its accreditation scope covers 29 test methods in the following areas: Water & wastewater, Environment, Materials & polymers, Petrochemistry & fuels. Test objects include: Water, wastewater, Soil, Soil, fertilisers: compost, sewage sludge, Waste O): code 01 04 08, 01 04 10, 01 04 12, 10 01 02, 10 01 20, 10….

At a glance

  • Accreditation number: PCA AB 1249
  • Methods in scope: 29
  • Types of test objects: 7
  • City: Wrocław, Poland
Accreditation number
AB 1249
Accreditation body
PCA
Address
LABORATORIUM ANALIZ ŚRODOWISKOWYCH, ul. Opolska 140, 52-014 Wrocław
City
Wrocław, Poland

What this laboratory tests (7)

Accreditation scope — test methods (29)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Water, wastewater Concentration of monoaromatic hydrocarbons Range: benzene (1,0 – 1000) μg/dm3 toluene (1,0 – 1000) μg/dm3 ethylbenzene (1,0 – 1000) μg/dm3 m+p-xylene (1,0 – 2000) μg/dm3 o-xylene (1,0 – 1000) μg/dm3 Gas chromatography method with flame ionisation detection (GC-FID) Procedura badawcza PB-1 wydanie 4 z dnia 17.12.2019 r.
2 Water, wastewater Mineral oil index Range: (0,10 – 100) mg/ dm3 Gas chromatography with flame ionisation detection (GC-FID) PN-EN ISO 9377-2:2003
3 Water, wastewater Concentration of petroleum hydrocarbons Range: Gasoline C6-C12 (0,010 – 100) mg/dm3 Oil C12-C35 (0,80 – 100) mg/dm3 Gas chromatography method with flame ionisation detection (GC-FID) Concentration of petroleum hydrocarbons C6-C35 (calculated) Procedura badawcza PB-1 wydanie 4 z dnia 17.12.2019 r.
4 Water, wastewater Anion concentrations Range: fluorides (0,1 – 100) mg/dm3 chlorides (0,2 – 1000) mg/dm3 bromides (0,05 – 25) mg/dm3 phosphates (0,08 – 50) mg/dm3 sulfates (0,2 – 1000) mg/dm3 nitrates (III) (0,02 – 10) mg/dm3 nitrates (V) (0,02 – 25) mg/dm3 N-NO (0,005 – 3,04) mg/dm3 2 N-NO (0,005 – 5,65) mg/dm3 3 P-PO (0,03 – 16,3) mg/dm3 4 Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009
5 Water, wastewater Metal concentrations Range: lead (2,0 – 600) μg/dm3 cadmium (0,2 – 40,0) μg/dm3 nickel (2,5 – 600) μg/dm3 chromium (2,0 – 200) μg/dm3 copper (3,0 – 600) μg/dm3 arsenic (3,0 – 1200) μg/dm3 Electrothermal atomization atomic absorption spectrometry (ETAAS) PN-EN ISO 15586:2005
6 Water, wastewater Element concentrations Range: zinc (0,01 – 10) mg/dm3 cobalt (0,01 – 10) mg/dm3 manganese (0,005 – 10) mg/dm3 iron (0,01 – 20) mg/dm3 tin (0,0020 – 50,0) mg/dm3 thallium 0,050 – 50,0) mg/dm3 arsenic (0,010 – 50,0) mg/dm3 selenium 0,050 – 50,0) mg/dm3 molybdenum (0,0020 – 50,0) mg/dm3 antimony (0,050 – 50,0) mg/dm3 cadmium (0,0020 – 50,0) mg/dm3 lead (0,0040 – 50,0) mg/dm3 nickel (0,0020 – 50,0) mg/dm3 chromium (0,0020 – 50,0) mg/dm3 vanadium (0,0020 – 50,0) mg/dm3 beryllium (0,0020 – 50,0) mg/dm3 copper (0,0020 – 50,0) mg/dm3 silver (0,0040 – 50,0) mg/dm3 aluminium (0,050 – 50,0) mg/dm3 barium (0,0020 – 50,0) mg/dm3 Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009
7 Water, wastewater Cation concentration Range: lithium (5,0 – 1000) mg/dm3 sodium (5,0 – 1000) mg/dm3 ammonium ion (0,15 – 10) mg/dm3 potassium (5,0 – 500) mg/dm3 magnesium (5,0 – 500) mg/dm3 calcium (5,0 – 1000) mg/dm3 ammonium nitrogen (0,12 – 7,78) mg/dm3 Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 14911:2002
8 Water, wastewater pH Range: 3,0 – 12,0 Potentiometric method PN-EN ISO 10523:2012
9 Water, wastewater Electrical conductivity Range: (10 – 50000) µS/cm Conductometric method PN-EN 27888:1999
10 Water, wastewater Concentration of polycyclic aromatic hydrocarbons (PAH) Range: - benzo(a)anthracene (3,0 – 1000) ng/dm3 - chrysene (3,0 – 1000) ng/dm3 - benzo(b)fluoranthene (3,0 – 1000) ng/dm3 - benzo(k)fluoranthene (3,0 – 1000) ng/dm3 - benzo(a)pyrene (3,0 – 1000) ng/dm3 - dibenzo(a,h)anthracene (3,0 – 1000) ng/dm3 - benzo(g,h,i)perylene (3,0 – 1000) ng/dm3 - Indeno(1,2,3-cd)pyrene (3,0 – 1000) ng/dm3 High performance liquid chromatography method with fluorescence detection (HPLC-FLD) Sum of PAH: (calculated) PN-EN ISO 17993:2005
11 Water, wastewater Total suspended solids Range: (2,0 – 4000) mg/dm3 Gravimetric method PN-EN 872:2007+Ap1:2007
12 Water, wastewater Total phosphorus concentration Range: (0,020 – 50,0) mg/dm3 Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009
13 Water, wastewater Mercury concentration Range: (0,0040 – 5,0) mg/dm3 Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009
14 Water Sampling for chemical and physical testing PN-ISO 5667-11:2017-10 z wyłączeniem pkt. 5.2 | PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5 | PN-ISO 5667-4:2017-10 z wyłączeniem pkt. 13
15 Water Mercury concentration Range: (0,0010 – 0,050) mg/dm3 Inductively coupled plasma optical emission spectrometry with hydride generation (HG-ICP-OES) PN-EN ISO 11885:2009
16 Wastewater Sampling for chemical and physical testing Manual method PN-ISO 5667-10:2021-11
17 Waste O): code 01 01 02, 01 04 08, 01 04 09, 02 03 99, 04 02 09, 04 02 20, 07 01 99, 10 12 05, 12 01 03, 12 01 21, 16 03 06, 16 81 02, 17 05 03, 17 05 07, 17 05 08, 17 06 04, 17 09 04, 19 06 06, 19 08 01, 19 08 12, 19 08 14, 19 12 09, 19 12 12, 19 13 02 01 04 10, 01 04 12, 10 01 02, 10 01 20, 10 01 21, 10 02 01, 10 09 07, 10 09 08, 10 09 11, 10 09 12, 10 10 12, 10 10 11, 10 12 03, 10 12 08, 10 13 06, 12 01 17, 17 01 81 Anion content Range: fluorides (1,0 – 1000) mg/kg chlorides (2,0 – 100000) mg/kg sulphates (2,0 – 100000) mg/kg Ion chromatography method with conductometric detection (IC-CD) PN-EN 12457-2:2006 PN-EN ISO 10304-1:2009
18 Waste O): code 01 04 08, 01 04 10, 01 04 12, 10 01 02, 10 01 20, 10 01 21, 10 02 01, 10 09 07, 10 09 08, 10 09 11, 10 09 12, 10 10 12, 10 10 11, 10 12 03, 10 12 08, 10 13 06, 12 01 17, 17 01 81 Content of elements Range: arsenic (0,10 – 500,0) mg/kg molybdenum (0,020 – 500,0) mg/kg cadmium (0,020 – 500,0) mg/kg lead (0,040 – 500,0) mg/kg nickel (0,020 – 500,0) mg/kg chromium (0,020 – 500,0) mg/kg copper (0,020 – 500,0) mg/kg barium (0,020 – 500,0) mg/kg mercury (0,040 – 50,0) mg/kg zinc (0,10 – 100,0) mg/kg selenium (0,060 – 500,0) mg/kg antimony (0,060 – 500,0) mg/kg Inductively coupled plasma atomic emission spectrometry (ICP-OES) method PN-EN 12457-2:2006 PN-EN ISO 11885:2009
19 Waste O): code 01 04 08, 01 04 10, 01 04 12, 10 01 02, 10 01 20, 10 01 21, 10 02 01, 10 09 07, 10 09 08, 10 09 11, 10 09 12, 10 10 12, 10 10 11, 10 12 03, 10 12 08, 10 13 06, 12 01 17, 17 01 81 Content of elements Range: mercury (0,010 – 0,50) mg/kg Hydride generation inductively coupled plasma atomic emission spectrometry (HG-ICP-OES) method PN-EN 12457-2:2006 PN-EN ISO 11885:2009
20 Soil Content of monoaromatic hydrocarbons Range: benzene (0,10 – 20) mg/kg toluene (0,10 – 20) mg/kg ethylbenzene (0,10 – 20) mg/kg m+p-xylene (0,10 – 40) mg/kg o-xylene (0,10 – 20) mg/kg Gas chromatography with flame ionization detection (GC-FID) method Procedura badawcza PB-1 wydanie 4 z dnia 17.12.2019 r.
21 Soil Content of petroleum hydrocarbons Range: Petrol C6-C12 (0,30 – 10000) mg/kg Oil C12-C35 (8,0 – 10000) mg/kg Gas chromatography with flame ionization detection (GC-FID) method Content of petroleum hydrocarbons C6-C35 (calculated) Procedura badawcza PB-1 wydanie 4 z dnia 17.12.2019 r.
22 Soil Dry matter Range: (0,1 – 99,9) % Gravimetric method PN-ISO 11465:1999
23 Soil Electrical conductivity Range: (10 – 50000) µS/cm Conductometric method PN-ISO 11265+AC1:1997
24 Soil Content of polycyclic aromatic hydrocarbons (PAH) Range: Naphthalene (0,015 – 1000) mg/kg Acenaphthylene (10 – 1000) mg/kg Acenaphthene (10 – 1000) mg/kg Fluorene (0,50 – 1000) mg/kg Phenanthrene (0,010 – 500) mg/kg Anthracene (0,010 – 1000) mg/kg Fluoranthene (0,050 – 500) mg/kg Pyrene (0,010 – 500) mg/kg Benzo(a)anthracene (0,010 – 500) mg/kg Chrysene (0,010 – 500) mg/kg Benzo(b)fluoranthene (0,010 – 500) mg/kg Benzo(k)fluoranthene (0,010 – 500) mg/kg Benzo(a)pyrene (0,0060 – 500) mg/kg Dibenzo(a,h)anthracene (0,010 – 500) mg/kg Benzo(g,h,i)perylene (0,010 – 500) mg/kg Indeno(1,2,3-cd)pyrene (0,010 – 500) mg/kg High performance liquid chromatography with fluorescence detection (HPLC-FLD) and with UV detection (HPLC-UV) method Sum of PAH (calculated) PN-ISO 13877:2004 z wyłączeniem pkt. 7 Instrukcja I-13 wydanie 4 z dnia 17.12.2019 r.
25 Soil Sampling for chemical and physical testing PN-ISO 10381-5:2009
26 Soil Anion content Range: fluorides (0,5 – 500) mg/kg chlorides (1,0 – 5000) mg/kg bromides (0,25 – 125) mg/kg phosphates (0,4 – 250) mg/kg sulphates (1,0 – 5000) mg/kg nitrites (III) (0,1 – 50) mg/kg nitrates (V) (0,10 – 125) mg/kg N-NO (0,025 – 15) mg/kg 2 N-NO (0,025 – 28) mg/kg 3 P-PO (0,15 – 82) mg/kg 4 Ion chromatography method with conductometric detection (IC-CD) Procedura badawcza PB-3 wydanie 6 z dnia 10.01.2020 r. PN-EN ISO 10304-1:2009
27 Soil Cation content Range: lithium (25 – 500) mg/kg sodium (25 – 5000) mg/kg ammonium ion (0,75 – 50) mg/kg potassium (25 – 5000) mg/kg magnesium (25 – 2500) mg/kg calcium (25 – 5000) mg/kg ammonium nitrogen (0,60 – 39) mg/kg Ion chromatography method with conductometric detection (IC-CD) Procedura badawcza PB-3 wydanie 6 z dnia 10.01.2020 r. PN-EN ISO 14911:2002
28 Soil, fertilisers: compost, sewage sludge pH - in H O, in KCl, in CaCl 2 2 Range: 3,0 – 12,0 Potentiometric method PN-ISO 10390:2022-09
29 Soil, fertilisers: compost, sewage sludge Content of elements Range: arsenic (3,0 – 5000) mg/kg barium (1,0 – 5000) mg/kg chromium (1,0 – 5000) mg/kg tin (1,0 – 5000) mg/kg zinc (1,0 – 5000) mg/kg cadmium (0,25 – 5000) mg/kg cobalt (1,0 – 5000) mg/kg copper (1,0 – 5000) mg/kg manganese (1,0 – 5000) mg/kg molybdenum (1,0 – 5000) mg/kg nickel (1,0 – 5000) mg/kg lead (1,0 – 5000) mg/kg mercury (0,50 – 2500) mg/kg phosphorus (5,0 – 5000) mg/kg magnesium (1,0 – 5000) mg/kg calcium (125 – 25000) mg/kg potassium (125 – 25000) mg/kg Inductively coupled plasma atomic emission spectrometry (ICP-OES) method PN-EN 16170:2017-02

Reference standards (24)

PN-EN 12457-2:2006 PN-EN ISO 10304-1:2009
PN-EN 12457-2:2006 PN-EN ISO 11885:2009
PN-EN 16170:2017-02
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10304-1:2009
PN-EN ISO 10523:2012
PN-EN ISO 11885:2009
PN-EN ISO 14911:2002
PN-EN ISO 15586:2005
PN-EN ISO 17993:2005
PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5
PN-EN ISO 9377-2:2003
PN-ISO 10381-5:2009
PN-ISO 10390:2022-09
PN-ISO 11265+AC1:1997
PN-ISO 11465:1999
PN-ISO 13877:2004 z wyłączeniem pkt. 7 Instrukcja I-13 wydanie 4 z dnia 17.12.2019 r.
PN-ISO 5667-10:2021-11
PN-ISO 5667-11:2017-10 z wyłączeniem pkt. 5.2
PN-ISO 5667-4:2017-10 z wyłączeniem pkt. 13
Procedura badawcza PB-1 wydanie 4 z dnia 17.12.2019 r.
Procedura badawcza PB-3 wydanie 6 z dnia 10.01.2020 r. PN-EN ISO 10304-1:2009
Procedura badawcza PB-3 wydanie 6 z dnia 10.01.2020 r. PN-EN ISO 14911:2002