🇵🇱 DOROTA PRZĄDO DM PL
Water & wastewaterEnvironmentMaterials & polymersPetrochemistry & fuels
DOROTA PRZĄDO DM is a laboratory accredited by PCA under number AB 1249 (Wrocław, Poland). Its accreditation scope covers 29 test methods in the following areas: Water & wastewater, Environment, Materials & polymers, Petrochemistry & fuels. Test objects include: Water, wastewater, Soil, Soil, fertilisers: compost, sewage sludge, Waste O): code 01 04 08, 01 04 10, 01 04 12, 10 01 02, 10 01 20, 10….
At a glance
- Accreditation number: PCA AB 1249
- Methods in scope: 29
- Types of test objects: 7
- City: Wrocław, Poland
- Accreditation number
- AB 1249
- Accreditation body
- PCA
- Address
- LABORATORIUM ANALIZ ŚRODOWISKOWYCH, ul. Opolska 140, 52-014 Wrocław
- City
- Wrocław, Poland
What this laboratory tests (7)
- Water, wastewater — 13 methods
- Soil — 8 methods
- Soil, fertilisers: compost, sewage sludge — 2 methods
- Waste O): code 01 04 08, 01 04 10, 01 04 12, 10 01 02, 10 01 20, 10 01 21, 10 02 01, 10 09 07, 10 09 08, 10 09 11, 10 09 12, 10 10 12, 10 10 11, 10 12 03, 10 12 08, 10 13 06, 12 01 17, 17 01 81 — 2 methods
- Water — 2 methods
- Waste O): code 01 01 02, 01 04 08, 01 04 09, 02 03 99, 04 02 09, 04 02 20, 07 01 99, 10 12 05, 12 01 03, 12 01 21, 16 03 06, 16 81 02, 17 05 03, 17 05 07, 17 05 08, 17 06 04, 17 09 04, 19 06 06, 19 08 01, 19 08 12, 19 08 14, 19 12 09, 19 12 12, 19 13 02 01 04 10, 01 04 12, 10 01 02, 10 01 20, 10 01 21, 10 02 01, 10 09 07, 10 09 08, 10 09 11, 10 09 12, 10 10 12, 10 10 11, 10 12 03, 10 12 08, 10 13 06, 12 01 17, 17 01 81 — 1 method
- Wastewater — 1 method
Accreditation scope — test methods (29)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Water, wastewater | Concentration of monoaromatic hydrocarbons Range: benzene (1,0 – 1000) μg/dm3 toluene (1,0 – 1000) μg/dm3 ethylbenzene (1,0 – 1000) μg/dm3 m+p-xylene (1,0 – 2000) μg/dm3 o-xylene (1,0 – 1000) μg/dm3 Gas chromatography method with flame ionisation detection (GC-FID) | Procedura badawcza PB-1 wydanie 4 z dnia 17.12.2019 r. | ||
| 2 | Water, wastewater | Mineral oil index Range: (0,10 – 100) mg/ dm3 Gas chromatography with flame ionisation detection (GC-FID) | PN-EN ISO 9377-2:2003 | ||
| 3 | Water, wastewater | Concentration of petroleum hydrocarbons Range: Gasoline C6-C12 (0,010 – 100) mg/dm3 Oil C12-C35 (0,80 – 100) mg/dm3 Gas chromatography method with flame ionisation detection (GC-FID) Concentration of petroleum hydrocarbons C6-C35 (calculated) | Procedura badawcza PB-1 wydanie 4 z dnia 17.12.2019 r. | ||
| 4 | Water, wastewater | Anion concentrations Range: fluorides (0,1 – 100) mg/dm3 chlorides (0,2 – 1000) mg/dm3 bromides (0,05 – 25) mg/dm3 phosphates (0,08 – 50) mg/dm3 sulfates (0,2 – 1000) mg/dm3 nitrates (III) (0,02 – 10) mg/dm3 nitrates (V) (0,02 – 25) mg/dm3 N-NO (0,005 – 3,04) mg/dm3 2 N-NO (0,005 – 5,65) mg/dm3 3 P-PO (0,03 – 16,3) mg/dm3 4 Ion chromatography with conductometric detection (IC-CD) | PN-EN ISO 10304-1:2009 | ||
| 5 | Water, wastewater | Metal concentrations Range: lead (2,0 – 600) μg/dm3 cadmium (0,2 – 40,0) μg/dm3 nickel (2,5 – 600) μg/dm3 chromium (2,0 – 200) μg/dm3 copper (3,0 – 600) μg/dm3 arsenic (3,0 – 1200) μg/dm3 Electrothermal atomization atomic absorption spectrometry (ETAAS) | PN-EN ISO 15586:2005 | ||
| 6 | Water, wastewater | Element concentrations Range: zinc (0,01 – 10) mg/dm3 cobalt (0,01 – 10) mg/dm3 manganese (0,005 – 10) mg/dm3 iron (0,01 – 20) mg/dm3 tin (0,0020 – 50,0) mg/dm3 thallium 0,050 – 50,0) mg/dm3 arsenic (0,010 – 50,0) mg/dm3 selenium 0,050 – 50,0) mg/dm3 molybdenum (0,0020 – 50,0) mg/dm3 antimony (0,050 – 50,0) mg/dm3 cadmium (0,0020 – 50,0) mg/dm3 lead (0,0040 – 50,0) mg/dm3 nickel (0,0020 – 50,0) mg/dm3 chromium (0,0020 – 50,0) mg/dm3 vanadium (0,0020 – 50,0) mg/dm3 beryllium (0,0020 – 50,0) mg/dm3 copper (0,0020 – 50,0) mg/dm3 silver (0,0040 – 50,0) mg/dm3 aluminium (0,050 – 50,0) mg/dm3 barium (0,0020 – 50,0) mg/dm3 Inductively coupled plasma optical emission spectrometry (ICP-OES) | PN-EN ISO 11885:2009 | ||
| 7 | Water, wastewater | Cation concentration Range: lithium (5,0 – 1000) mg/dm3 sodium (5,0 – 1000) mg/dm3 ammonium ion (0,15 – 10) mg/dm3 potassium (5,0 – 500) mg/dm3 magnesium (5,0 – 500) mg/dm3 calcium (5,0 – 1000) mg/dm3 ammonium nitrogen (0,12 – 7,78) mg/dm3 Ion chromatography with conductometric detection (IC-CD) | PN-EN ISO 14911:2002 | ||
| 8 | Water, wastewater | pH Range: 3,0 – 12,0 Potentiometric method | PN-EN ISO 10523:2012 | ||
| 9 | Water, wastewater | Electrical conductivity Range: (10 – 50000) µS/cm Conductometric method | PN-EN 27888:1999 | ||
| 10 | Water, wastewater | Concentration of polycyclic aromatic hydrocarbons (PAH) Range: - benzo(a)anthracene (3,0 – 1000) ng/dm3 - chrysene (3,0 – 1000) ng/dm3 - benzo(b)fluoranthene (3,0 – 1000) ng/dm3 - benzo(k)fluoranthene (3,0 – 1000) ng/dm3 - benzo(a)pyrene (3,0 – 1000) ng/dm3 - dibenzo(a,h)anthracene (3,0 – 1000) ng/dm3 - benzo(g,h,i)perylene (3,0 – 1000) ng/dm3 - Indeno(1,2,3-cd)pyrene (3,0 – 1000) ng/dm3 High performance liquid chromatography method with fluorescence detection (HPLC-FLD) Sum of PAH: (calculated) | PN-EN ISO 17993:2005 | ||
| 11 | Water, wastewater | Total suspended solids Range: (2,0 – 4000) mg/dm3 Gravimetric method | PN-EN 872:2007+Ap1:2007 | ||
| 12 | Water, wastewater | Total phosphorus concentration Range: (0,020 – 50,0) mg/dm3 Inductively coupled plasma optical emission spectrometry (ICP-OES) | PN-EN ISO 11885:2009 | ||
| 13 | Water, wastewater | Mercury concentration Range: (0,0040 – 5,0) mg/dm3 Inductively coupled plasma optical emission spectrometry (ICP-OES) | PN-EN ISO 11885:2009 | ||
| 14 | Water | Sampling for chemical and physical testing | PN-ISO 5667-11:2017-10 z wyłączeniem pkt. 5.2 | PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5 | PN-ISO 5667-4:2017-10 z wyłączeniem pkt. 13 | ||
| 15 | Water | Mercury concentration Range: (0,0010 – 0,050) mg/dm3 Inductively coupled plasma optical emission spectrometry with hydride generation (HG-ICP-OES) | PN-EN ISO 11885:2009 | ||
| 16 | Wastewater | Sampling for chemical and physical testing Manual method | PN-ISO 5667-10:2021-11 | ||
| 17 | Waste O): code 01 01 02, 01 04 08, 01 04 09, 02 03 99, 04 02 09, 04 02 20, 07 01 99, 10 12 05, 12 01 03, 12 01 21, 16 03 06, 16 81 02, 17 05 03, 17 05 07, 17 05 08, 17 06 04, 17 09 04, 19 06 06, 19 08 01, 19 08 12, 19 08 14, 19 12 09, 19 12 12, 19 13 02 01 04 10, 01 04 12, 10 01 02, 10 01 20, 10 01 21, 10 02 01, 10 09 07, 10 09 08, 10 09 11, 10 09 12, 10 10 12, 10 10 11, 10 12 03, 10 12 08, 10 13 06, 12 01 17, 17 01 81 | Anion content Range: fluorides (1,0 – 1000) mg/kg chlorides (2,0 – 100000) mg/kg sulphates (2,0 – 100000) mg/kg Ion chromatography method with conductometric detection (IC-CD) | PN-EN 12457-2:2006 PN-EN ISO 10304-1:2009 | ||
| 18 | Waste O): code 01 04 08, 01 04 10, 01 04 12, 10 01 02, 10 01 20, 10 01 21, 10 02 01, 10 09 07, 10 09 08, 10 09 11, 10 09 12, 10 10 12, 10 10 11, 10 12 03, 10 12 08, 10 13 06, 12 01 17, 17 01 81 | Content of elements Range: arsenic (0,10 – 500,0) mg/kg molybdenum (0,020 – 500,0) mg/kg cadmium (0,020 – 500,0) mg/kg lead (0,040 – 500,0) mg/kg nickel (0,020 – 500,0) mg/kg chromium (0,020 – 500,0) mg/kg copper (0,020 – 500,0) mg/kg barium (0,020 – 500,0) mg/kg mercury (0,040 – 50,0) mg/kg zinc (0,10 – 100,0) mg/kg selenium (0,060 – 500,0) mg/kg antimony (0,060 – 500,0) mg/kg Inductively coupled plasma atomic emission spectrometry (ICP-OES) method | PN-EN 12457-2:2006 PN-EN ISO 11885:2009 | ||
| 19 | Waste O): code 01 04 08, 01 04 10, 01 04 12, 10 01 02, 10 01 20, 10 01 21, 10 02 01, 10 09 07, 10 09 08, 10 09 11, 10 09 12, 10 10 12, 10 10 11, 10 12 03, 10 12 08, 10 13 06, 12 01 17, 17 01 81 | Content of elements Range: mercury (0,010 – 0,50) mg/kg Hydride generation inductively coupled plasma atomic emission spectrometry (HG-ICP-OES) method | PN-EN 12457-2:2006 PN-EN ISO 11885:2009 | ||
| 20 | Soil | Content of monoaromatic hydrocarbons Range: benzene (0,10 – 20) mg/kg toluene (0,10 – 20) mg/kg ethylbenzene (0,10 – 20) mg/kg m+p-xylene (0,10 – 40) mg/kg o-xylene (0,10 – 20) mg/kg Gas chromatography with flame ionization detection (GC-FID) method | Procedura badawcza PB-1 wydanie 4 z dnia 17.12.2019 r. | ||
| 21 | Soil | Content of petroleum hydrocarbons Range: Petrol C6-C12 (0,30 – 10000) mg/kg Oil C12-C35 (8,0 – 10000) mg/kg Gas chromatography with flame ionization detection (GC-FID) method Content of petroleum hydrocarbons C6-C35 (calculated) | Procedura badawcza PB-1 wydanie 4 z dnia 17.12.2019 r. | ||
| 22 | Soil | Dry matter Range: (0,1 – 99,9) % Gravimetric method | PN-ISO 11465:1999 | ||
| 23 | Soil | Electrical conductivity Range: (10 – 50000) µS/cm Conductometric method | PN-ISO 11265+AC1:1997 | ||
| 24 | Soil | Content of polycyclic aromatic hydrocarbons (PAH) Range: Naphthalene (0,015 – 1000) mg/kg Acenaphthylene (10 – 1000) mg/kg Acenaphthene (10 – 1000) mg/kg Fluorene (0,50 – 1000) mg/kg Phenanthrene (0,010 – 500) mg/kg Anthracene (0,010 – 1000) mg/kg Fluoranthene (0,050 – 500) mg/kg Pyrene (0,010 – 500) mg/kg Benzo(a)anthracene (0,010 – 500) mg/kg Chrysene (0,010 – 500) mg/kg Benzo(b)fluoranthene (0,010 – 500) mg/kg Benzo(k)fluoranthene (0,010 – 500) mg/kg Benzo(a)pyrene (0,0060 – 500) mg/kg Dibenzo(a,h)anthracene (0,010 – 500) mg/kg Benzo(g,h,i)perylene (0,010 – 500) mg/kg Indeno(1,2,3-cd)pyrene (0,010 – 500) mg/kg High performance liquid chromatography with fluorescence detection (HPLC-FLD) and with UV detection (HPLC-UV) method Sum of PAH (calculated) | PN-ISO 13877:2004 z wyłączeniem pkt. 7 Instrukcja I-13 wydanie 4 z dnia 17.12.2019 r. | ||
| 25 | Soil | Sampling for chemical and physical testing | PN-ISO 10381-5:2009 | ||
| 26 | Soil | Anion content Range: fluorides (0,5 – 500) mg/kg chlorides (1,0 – 5000) mg/kg bromides (0,25 – 125) mg/kg phosphates (0,4 – 250) mg/kg sulphates (1,0 – 5000) mg/kg nitrites (III) (0,1 – 50) mg/kg nitrates (V) (0,10 – 125) mg/kg N-NO (0,025 – 15) mg/kg 2 N-NO (0,025 – 28) mg/kg 3 P-PO (0,15 – 82) mg/kg 4 Ion chromatography method with conductometric detection (IC-CD) | Procedura badawcza PB-3 wydanie 6 z dnia 10.01.2020 r. PN-EN ISO 10304-1:2009 | ||
| 27 | Soil | Cation content Range: lithium (25 – 500) mg/kg sodium (25 – 5000) mg/kg ammonium ion (0,75 – 50) mg/kg potassium (25 – 5000) mg/kg magnesium (25 – 2500) mg/kg calcium (25 – 5000) mg/kg ammonium nitrogen (0,60 – 39) mg/kg Ion chromatography method with conductometric detection (IC-CD) | Procedura badawcza PB-3 wydanie 6 z dnia 10.01.2020 r. PN-EN ISO 14911:2002 | ||
| 28 | Soil, fertilisers: compost, sewage sludge | pH - in H O, in KCl, in CaCl 2 2 Range: 3,0 – 12,0 Potentiometric method | PN-ISO 10390:2022-09 | ||
| 29 | Soil, fertilisers: compost, sewage sludge | Content of elements Range: arsenic (3,0 – 5000) mg/kg barium (1,0 – 5000) mg/kg chromium (1,0 – 5000) mg/kg tin (1,0 – 5000) mg/kg zinc (1,0 – 5000) mg/kg cadmium (0,25 – 5000) mg/kg cobalt (1,0 – 5000) mg/kg copper (1,0 – 5000) mg/kg manganese (1,0 – 5000) mg/kg molybdenum (1,0 – 5000) mg/kg nickel (1,0 – 5000) mg/kg lead (1,0 – 5000) mg/kg mercury (0,50 – 2500) mg/kg phosphorus (5,0 – 5000) mg/kg magnesium (1,0 – 5000) mg/kg calcium (125 – 25000) mg/kg potassium (125 – 25000) mg/kg Inductively coupled plasma atomic emission spectrometry (ICP-OES) method | PN-EN 16170:2017-02 | ||
Reference standards (24)
PN-EN 12457-2:2006 PN-EN ISO 10304-1:2009
PN-EN 12457-2:2006 PN-EN ISO 11885:2009
PN-EN 16170:2017-02
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10304-1:2009
PN-EN ISO 10523:2012
PN-EN ISO 11885:2009
PN-EN ISO 14911:2002
PN-EN ISO 15586:2005
PN-EN ISO 17993:2005
PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5
PN-EN ISO 9377-2:2003
PN-ISO 10381-5:2009
PN-ISO 10390:2022-09
PN-ISO 11265+AC1:1997
PN-ISO 11465:1999
PN-ISO 13877:2004 z wyłączeniem pkt. 7 Instrukcja I-13 wydanie 4 z dnia 17.12.2019 r.
PN-ISO 5667-10:2021-11
PN-ISO 5667-11:2017-10 z wyłączeniem pkt. 5.2
PN-ISO 5667-4:2017-10 z wyłączeniem pkt. 13
Procedura badawcza PB-1 wydanie 4 z dnia 17.12.2019 r.
Procedura badawcza PB-3 wydanie 6 z dnia 10.01.2020 r. PN-EN ISO 10304-1:2009
Procedura badawcza PB-3 wydanie 6 z dnia 10.01.2020 r. PN-EN ISO 14911:2002