{"lab":{"_id":"69ad52a3de79e566650fb664","accr_number":"AB 1249","country":"PL","accr_body":"PCA","address":"LABORATORIUM ANALIZ ŚRODOWISKOWYCH, ul. Opolska 140, 52-014 Wrocław","categories":["water","environment","materials","petro"],"city":"Wrocław","imported_at":"2026-03-08T10:42:43.265Z","methods_count":29,"name":"DOROTA PRZĄDO DM","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1249.pdf"],"scope_summary":"","search_text":"dorota prządo dm laboratorium analiz środowiskowych, ul. opolska 140, 52-014 wrocław water other food petro materials pharma electronics environment","status":"active","updated_at":"2026-03-08T14:50:25.408Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:25.408Z","email_confidence":"high","email_mx":true,"email_source":"https://www.dmlaboratorium.pl/pl/kontakt","parse_date":"2026-07-17T16:19:00.601Z","parse_source":"m5-mistral-qa","fields_of_testing":[{"codes":"C/32; C/43","pl":"Badania chemiczne odpadów, nawozów","en":"Chemical tests of waste, fertilizers"},{"codes":"C/28/P; C/30/P; C/31/P","pl":"Badania chemiczne i pobieranie próbek wody, ścieków, gleby","en":"Chemical tests and sampling of water, sewage, soil"},{"codes":"N/43","pl":"Badania właściwości fizycznych nawozów","en":"Tests of physical properties fertilizers"},{"codes":"N/28/P; N/30/P; N/31/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, ścieków, gleby","en":"Tests of physical properties and sampling of water, sewage, soil"}],"issue":{"no":"16","date":"19.01.2026"},"map_coord":[51.070495,17.092611],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":18,"environment":13,"materials":4,"petro":3},"category_scores":{"water":8.53,"environment":4.45,"materials":0.42,"petro":0.24},"has_zh":true},"methods":[{"_id":"6a5a55f49af9f73f3825199a","lab_id":"69ad52a3de79e566650fb664","country":"PL","accr_number":"AB 1249","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie węglowodorów monoaromatycznych Zakres: benzen (1,0 – 1000) μg/dm3 toluen (1,0 – 1000) μg/dm3 etylobenzen (1,0 – 1000) μg/dm3 m+p-ksylen (1,0 – 2000) μg/dm3 o-ksylen (1,0 – 1000) μg/dm3 Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","methodology_en":"Concentration of monoaromatic hydrocarbons Range: benzene (1,0 – 1000) μg/dm3 toluene (1,0 – 1000) μg/dm3 ethylbenzene (1,0 – 1000) μg/dm3 m+p-xylene (1,0 – 2000) μg/dm3 o-xylene (1,0 – 1000) μg/dm3 Gas chromatography method with flame ionisation detection (GC-FID)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie węglowodorów monoaromatycznych Zakres: benzen (1,0 – 1000) μg/dm3 toluen (1,0 – 1000) μg/dm3 etylobenzen (1,0 – 1000) μg/dm3 m+p-ksylen (1,0 – 2000) μg/dm3 o-ksylen (1,0 – 1000) μg/dm3 Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Procedura badawcza PB-1 wydanie 4 z dnia 17.12.2019 r.","norm_bases":["Procedura badawcza PB-1 wydanie 4 z dnia 17.12.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie węglowodorów monoaromatycznych Zakres: benzen (1,0 – 1000) μg/dm3 toluen (1,0 – 1000) μg/dm3 etylobenzen (1,0 – 1000) μg/dm3 m+p-ksylen (1,0 – 2000) μg/dm3 o-ksylen (1,0 – 1000) μg/dm3 Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Procedura badawcza PB-1 wydanie 4 z dnia 17.12.2019 r. Woda, scieki Stezenie weglowodorow monoaromatycznych Zakres: benzen (1,0 – 1000) μg/dm3 toluen (1,0 – 1000) μg/dm3 etylobenzen (1,0 – 1000) μg/dm3 m+p-ksylen (1,0 – 2000) μg/dm3 o-ksylen (1,0 – 1000) μg/dm3 Metoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Procedura badawcza PB-1 wydanie 4 z dnia 17.12.2019 r.","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Concentration of monoaromatic hydrocarbons Range: benzene (1,0 – 1000) μg/dm3 toluene (1,0 – 1000) μg/dm3 ethylbenzene (1,0 – 1000) μg/dm3 m+p-xylene (1,0 – 2000) μg/dm3 o-xylene (1,0 – 1000) μg/dm3 Gas chromatography method with flame ionisation detection (GC-FID) Procedura badawcza PB-1 wydanie 4 z dnia 17.12.2019 r.","search_zh":"水、废水 Procedura badawcza PB-1 wydanie 4 z dnia 17.12.2019 r.","test_object_zh":"水、废水"},{"_id":"6a5a55f49af9f73f3825199b","lab_id":"69ad52a3de79e566650fb664","country":"PL","accr_number":"AB 1249","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Indeks oleju mineralnego Zakres: (0,10 – 100) mg/ dm3 Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","methodology_en":"Mineral oil index Range: (0,10 – 100) mg/ dm3 Gas chromatography with flame ionisation detection (GC-FID)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Indeks oleju mineralnego Zakres: (0,10 – 100) mg/ dm3 Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 9377-2:2003","norm_bases":["PN-EN ISO 9377-2:2003"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Indeks oleju mineralnego Zakres: (0,10 – 100) mg/ dm3 Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 9377-2:2003 Woda, scieki Indeks oleju mineralnego Zakres: (0,10 – 100) mg/ dm3 Metoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 9377-2:2003","categories":["water","petro"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Mineral oil index Range: (0,10 – 100) mg/ dm3 Gas chromatography with flame ionisation detection (GC-FID) PN-EN ISO 9377-2:2003","search_zh":"水、废水 PN-EN ISO 9377-2:2003","test_object_zh":"水、废水"},{"_id":"6a5a55f49af9f73f3825199c","lab_id":"69ad52a3de79e566650fb664","country":"PL","accr_number":"AB 1249","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie węglowodorów ropopochodnych Zakres: Benzyna C6-C12 (0,010 – 100) mg/dm3 Olej C12-C35 (0,80 – 100) mg/dm3 Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Stężenie węglowodorów ropopochodnych C6-C35 (z obliczeń)","methodology_en":"Concentration of petroleum hydrocarbons Range: Gasoline C6-C12 (0,010 – 100) mg/dm3 Oil C12-C35 (0,80 – 100) mg/dm3 Gas chromatography method with flame ionisation detection (GC-FID) Concentration of petroleum hydrocarbons C6-C35 (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie węglowodorów ropopochodnych Zakres: Benzyna C6-C12 (0,010 – 100) mg/dm3 Olej C12-C35 (0,80 – 100) mg/dm3 Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Stężenie węglowodorów ropopochodnych C6-C35 (z obliczeń)","reference":"Procedura badawcza PB-1 wydanie 4 z dnia 17.12.2019 r.","norm_bases":["Procedura badawcza PB-1 wydanie 4 z dnia 17.12.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie węglowodorów ropopochodnych Zakres: Benzyna C6-C12 (0,010 – 100) mg/dm3 Olej C12-C35 (0,80 – 100) mg/dm3 Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Stężenie węglowodorów ropopochodnych C6-C35 (z obliczeń) Procedura badawcza PB-1 wydanie 4 z dnia 17.12.2019 r. Woda, scieki Stezenie weglowodorow ropopochodnych Zakres: Benzyna C6-C12 (0,010 – 100) mg/dm3 Olej C12-C35 (0,80 – 100) mg/dm3 Metoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Stezenie weglowodorow ropopochodnych C6-C35 (z obliczen) Procedura badawcza PB-1 wydanie 4 z dnia 17.12.2019 r.","categories":["water","petro"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Concentration of petroleum hydrocarbons Range: Gasoline C6-C12 (0,010 – 100) mg/dm3 Oil C12-C35 (0,80 – 100) mg/dm3 Gas chromatography method with flame ionisation detection (GC-FID) Concentration of petroleum hydrocarbons C6-C35 (calculated) Procedura badawcza PB-1 wydanie 4 z dnia 17.12.2019 r.","search_zh":"水、废水 Procedura badawcza PB-1 wydanie 4 z dnia 17.12.2019 r.","test_object_zh":"水、废水"},{"_id":"6a5a55f49af9f73f3825199d","lab_id":"69ad52a3de79e566650fb664","country":"PL","accr_number":"AB 1249","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie anionów Zakres: fluorki (0,1 – 100) mg/dm3 chlorki (0,2 – 1000) mg/dm3 bromki (0,05 – 25) mg/dm3 fosforany (0,08 – 50) mg/dm3 siarczany (0,2 – 1000) mg/dm3 azotany (III) (0,02 – 10) mg/dm3 azotany (V) (0,02 – 25) mg/dm3 N-NO (0,005 – 3,04) mg/dm3 2 N-NO (0,005 – 5,65) mg/dm3 3 P-PO (0,03 – 16,3) mg/dm3 4 Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","methodology_en":"Anion concentrations Range: fluorides (0,1 – 100) mg/dm3 chlorides (0,2 – 1000) mg/dm3 bromides (0,05 – 25) mg/dm3 phosphates (0,08 – 50) mg/dm3 sulfates (0,2 – 1000) mg/dm3 nitrates (III) (0,02 – 10) mg/dm3 nitrates (V) (0,02 – 25) mg/dm3 N-NO (0,005 – 3,04) mg/dm3 2 N-NO (0,005 – 5,65) mg/dm3 3 P-PO (0,03 – 16,3) mg/dm3 4 Ion chromatography with conductometric detection (IC-CD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie anionów Zakres: fluorki (0,1 – 100) mg/dm3 chlorki (0,2 – 1000) mg/dm3 bromki (0,05 – 25) mg/dm3 fosforany (0,08 – 50) mg/dm3 siarczany (0,2 – 1000) mg/dm3 azotany (III) (0,02 – 10) mg/dm3 azotany (V) (0,02 – 25) mg/dm3 N-NO (0,005 – 3,04) mg/dm3 2 N-NO (0,005 – 5,65) mg/dm3 3 P-PO (0,03 – 16,3) mg/dm3 4 Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009","norm_bases":["PN-EN ISO 10304-1:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie anionów Zakres: fluorki (0,1 – 100) mg/dm3 chlorki (0,2 – 1000) mg/dm3 bromki (0,05 – 25) mg/dm3 fosforany (0,08 – 50) mg/dm3 siarczany (0,2 – 1000) mg/dm3 azotany (III) (0,02 – 10) mg/dm3 azotany (V) (0,02 – 25) mg/dm3 N-NO (0,005 – 3,04) mg/dm3 2 N-NO (0,005 – 5,65) mg/dm3 3 P-PO (0,03 – 16,3) mg/dm3 4 Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009 Woda, scieki Stezenie anionow Zakres: fluorki (0,1 – 100) mg/dm3 chlorki (0,2 – 1000) mg/dm3 bromki (0,05 – 25) mg/dm3 fosforany (0,08 – 50) mg/dm3 siarczany (0,2 – 1000) mg/dm3 azotany (III) (0,02 – 10) mg/dm3 azotany (V) (0,02 – 25) mg/dm3 N-NO (0,005 – 3,04) mg/dm3 2 N-NO (0,005 – 5,65) mg/dm3 3 P-PO (0,03 – 16,3) mg/dm3 4 Metoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Anion concentrations Range: fluorides (0,1 – 100) mg/dm3 chlorides (0,2 – 1000) mg/dm3 bromides (0,05 – 25) mg/dm3 phosphates (0,08 – 50) mg/dm3 sulfates (0,2 – 1000) mg/dm3 nitrates (III) (0,02 – 10) mg/dm3 nitrates (V) (0,02 – 25) mg/dm3 N-NO (0,005 – 3,04) mg/dm3 2 N-NO (0,005 – 5,65) mg/dm3 3 P-PO (0,03 – 16,3) mg/dm3 4 Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009","search_zh":"水、废水 PN-EN ISO 10304-1:2009","test_object_zh":"水、废水"},{"_id":"6a5a55f49af9f73f3825199e","lab_id":"69ad52a3de79e566650fb664","country":"PL","accr_number":"AB 1249","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie metali Zakres: ołów (2,0 – 600) μg/dm3 kadm (0,2 – 40,0) μg/dm3 nikiel (2,5 – 600) μg/dm3 chrom (2,0 – 200) μg/dm3 miedź (3,0 – 600) μg/dm3 arsen (3,0 – 1200) μg/dm3 Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","methodology_en":"Metal concentrations Range: lead (2,0 – 600) μg/dm3 cadmium (0,2 – 40,0) μg/dm3 nickel (2,5 – 600) μg/dm3 chromium (2,0 – 200) μg/dm3 copper (3,0 – 600) μg/dm3 arsenic (3,0 – 1200) μg/dm3 Electrothermal atomization atomic absorption spectrometry (ETAAS)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie metali Zakres: ołów (2,0 – 600) μg/dm3 kadm (0,2 – 40,0) μg/dm3 nikiel (2,5 – 600) μg/dm3 chrom (2,0 – 200) μg/dm3 miedź (3,0 – 600) μg/dm3 arsen (3,0 – 1200) μg/dm3 Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","reference":"PN-EN ISO 15586:2005","norm_bases":["PN-EN ISO 15586:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie metali Zakres: ołów (2,0 – 600) μg/dm3 kadm (0,2 – 40,0) μg/dm3 nikiel (2,5 – 600) μg/dm3 chrom (2,0 – 200) μg/dm3 miedź (3,0 – 600) μg/dm3 arsen (3,0 – 1200) μg/dm3 Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS) PN-EN ISO 15586:2005 Woda, scieki Stezenie metali Zakres: olow (2,0 – 600) μg/dm3 kadm (0,2 – 40,0) μg/dm3 nikiel (2,5 – 600) μg/dm3 chrom (2,0 – 200) μg/dm3 miedz (3,0 – 600) μg/dm3 arsen (3,0 – 1200) μg/dm3 Metoda absorpcyjnej spektrometrii atomowej z atomizacja elektrotermiczna (ETAAS) PN-EN ISO 15586:2005","categories":["materials","water"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Metal concentrations Range: lead (2,0 – 600) μg/dm3 cadmium (0,2 – 40,0) μg/dm3 nickel (2,5 – 600) μg/dm3 chromium (2,0 – 200) μg/dm3 copper (3,0 – 600) μg/dm3 arsenic (3,0 – 1200) μg/dm3 Electrothermal atomization atomic absorption spectrometry (ETAAS) PN-EN ISO 15586:2005","search_zh":"水、废水 PN-EN ISO 15586:2005","test_object_zh":"水、废水"},{"_id":"6a5a55f49af9f73f3825199f","lab_id":"69ad52a3de79e566650fb664","country":"PL","accr_number":"AB 1249","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie pierwiastków Zakres: cynk (0,01 – 10) mg/dm3 kobalt (0,01 – 10) mg/dm3 mangan (0,005 – 10) mg/dm3 żelazo (0,01 – 20) mg/dm3 cyna (0,0020 – 50,0) mg/dm3 tal 0,050 – 50,0) mg/dm3 arsen (0,010 – 50,0) mg/dm3 selen 0,050 – 50,0) mg/dm3 molibden (0,0020 – 50,0) mg/dm3 antymon (0,050 – 50,0) mg/dm3 kadm (0,0020 – 50,0) mg/dm3 ołów (0,0040 – 50,0) mg/dm3 nikiel (0,0020 – 50,0) mg/dm3 chrom (0,0020 – 50,0) mg/dm3 wanad (0,0020 – 50,0) mg/dm3 beryl (0,0020 – 50,0) mg/dm3 miedź (0,0020 – 50,0) mg/dm3 srebro (0,0040 – 50,0) mg/dm3 glin (0,050 – 50,0) mg/dm3 bar (0,0020 – 50,0) mg/dm3 Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","methodology_en":"Element concentrations Range: zinc (0,01 – 10) mg/dm3 cobalt (0,01 – 10) mg/dm3 manganese (0,005 – 10) mg/dm3 iron (0,01 – 20) mg/dm3 tin (0,0020 – 50,0) mg/dm3 thallium 0,050 – 50,0) mg/dm3 arsenic (0,010 – 50,0) mg/dm3 selenium 0,050 – 50,0) mg/dm3 molybdenum (0,0020 – 50,0) mg/dm3 antimony (0,050 – 50,0) mg/dm3 cadmium (0,0020 – 50,0) mg/dm3 lead (0,0040 – 50,0) mg/dm3 nickel (0,0020 – 50,0) mg/dm3 chromium (0,0020 – 50,0) mg/dm3 vanadium (0,0020 – 50,0) mg/dm3 beryllium (0,0020 – 50,0) mg/dm3 copper (0,0020 – 50,0) mg/dm3 silver (0,0040 – 50,0) mg/dm3 aluminium (0,050 – 50,0) mg/dm3 barium (0,0020 – 50,0) mg/dm3 Inductively coupled plasma optical emission spectrometry (ICP-OES)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pierwiastków Zakres: cynk (0,01 – 10) mg/dm3 kobalt (0,01 – 10) mg/dm3 mangan (0,005 – 10) mg/dm3 żelazo (0,01 – 20) mg/dm3 cyna (0,0020 – 50,0) mg/dm3 tal 0,050 – 50,0) mg/dm3 arsen (0,010 – 50,0) mg/dm3 selen 0,050 – 50,0) mg/dm3 molibden (0,0020 – 50,0) mg/dm3 antymon (0,050 – 50,0) mg/dm3 kadm (0,0020 – 50,0) mg/dm3 ołów (0,0040 – 50,0) mg/dm3 nikiel (0,0020 – 50,0) mg/dm3 chrom (0,0020 – 50,0) mg/dm3 wanad (0,0020 – 50,0) mg/dm3 beryl (0,0020 – 50,0) mg/dm3 miedź (0,0020 – 50,0) mg/dm3 srebro (0,0040 – 50,0) mg/dm3 glin (0,050 – 50,0) mg/dm3 bar (0,0020 – 50,0) mg/dm3 Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie pierwiastków Zakres: cynk (0,01 – 10) mg/dm3 kobalt (0,01 – 10) mg/dm3 mangan (0,005 – 10) mg/dm3 żelazo (0,01 – 20) mg/dm3 cyna (0,0020 – 50,0) mg/dm3 tal 0,050 – 50,0) mg/dm3 arsen (0,010 – 50,0) mg/dm3 selen 0,050 – 50,0) mg/dm3 molibden (0,0020 – 50,0) mg/dm3 antymon (0,050 – 50,0) mg/dm3 kadm (0,0020 – 50,0) mg/dm3 ołów (0,0040 – 50,0) mg/dm3 nikiel (0,0020 – 50,0) mg/dm3 chrom (0,0020 – 50,0) mg/dm3 wanad (0,0020 – 50,0) mg/dm3 beryl (0,0020 – 50,0) mg/dm3 miedź (0,0020 – 50,0) mg/dm3 srebro (0,0040 – 50,0) mg/dm3 glin (0,050 – 50,0) mg/dm3 bar (0,0020 – 50,0) mg/dm3 Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Woda, scieki Stezenie pierwiastkow Zakres: cynk (0,01 – 10) mg/dm3 kobalt (0,01 – 10) mg/dm3 mangan (0,005 – 10) mg/dm3 zelazo (0,01 – 20) mg/dm3 cyna (0,0020 – 50,0) mg/dm3 tal 0,050 – 50,0) mg/dm3 arsen (0,010 – 50,0) mg/dm3 selen 0,050 – 50,0) mg/dm3 molibden (0,0020 – 50,0) mg/dm3 antymon (0,050 – 50,0) mg/dm3 kadm (0,0020 – 50,0) mg/dm3 olow (0,0040 – 50,0) mg/dm3 nikiel (0,0020 – 50,0) mg/dm3 chrom (0,0020 – 50,0) mg/dm3 wanad (0,0020 – 50,0) mg/dm3 beryl (0,0020 – 50,0) mg/dm3 miedz (0,0020 – 50,0) mg/dm3 srebro (0,0040 – 50,0) mg/dm3 glin (0,050 – 50,0) mg/dm3 bar (0,0020 – 50,0) mg/dm3 Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water","materials"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Element concentrations Range: zinc (0,01 – 10) mg/dm3 cobalt (0,01 – 10) mg/dm3 manganese (0,005 – 10) mg/dm3 iron (0,01 – 20) mg/dm3 tin (0,0020 – 50,0) mg/dm3 thallium 0,050 – 50,0) mg/dm3 arsenic (0,010 – 50,0) mg/dm3 selenium 0,050 – 50,0) mg/dm3 molybdenum (0,0020 – 50,0) mg/dm3 antimony (0,050 – 50,0) mg/dm3 cadmium (0,0020 – 50,0) mg/dm3 lead (0,0040 – 50,0) mg/dm3 nickel (0,0020 – 50,0) mg/dm3 chromium (0,0020 – 50,0) mg/dm3 vanadium (0,0020 – 50,0) mg/dm3 beryllium (0,0020 – 50,0) mg/dm3 copper (0,0020 – 50,0) mg/dm3 silver (0,0040 – 50,0) mg/dm3 aluminium (0,050 – 50,0) mg/dm3 barium (0,0020 – 50,0) mg/dm3 Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009","search_zh":"水、废水 PN-EN ISO 11885:2009","test_object_zh":"水、废水"},{"_id":"6a5a55f49af9f73f382519a0","lab_id":"69ad52a3de79e566650fb664","country":"PL","accr_number":"AB 1249","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie kationów Zakres: lit (5,0 – 1000) mg/dm3 sód (5,0 – 1000) mg/dm3 jon amonowy (0,15 – 10) mg/dm3 potas (5,0 – 500) mg/dm3 magnez (5,0 – 500) mg/dm3 wapń (5,0 – 1000) mg/dm3 azot amonowy (0,12 – 7,78) mg/dm3 Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","methodology_en":"Cation concentration Range: lithium (5,0 – 1000) mg/dm3 sodium (5,0 – 1000) mg/dm3 ammonium ion (0,15 – 10) mg/dm3 potassium (5,0 – 500) mg/dm3 magnesium (5,0 – 500) mg/dm3 calcium (5,0 – 1000) mg/dm3 ammonium nitrogen (0,12 – 7,78) mg/dm3 Ion chromatography with conductometric detection (IC-CD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie kationów Zakres: lit (5,0 – 1000) mg/dm3 sód (5,0 – 1000) mg/dm3 jon amonowy (0,15 – 10) mg/dm3 potas (5,0 – 500) mg/dm3 magnez (5,0 – 500) mg/dm3 wapń (5,0 – 1000) mg/dm3 azot amonowy (0,12 – 7,78) mg/dm3 Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 14911:2002","norm_bases":["PN-EN ISO 14911:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie kationów Zakres: lit (5,0 – 1000) mg/dm3 sód (5,0 – 1000) mg/dm3 jon amonowy (0,15 – 10) mg/dm3 potas (5,0 – 500) mg/dm3 magnez (5,0 – 500) mg/dm3 wapń (5,0 – 1000) mg/dm3 azot amonowy (0,12 – 7,78) mg/dm3 Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 14911:2002 Woda, scieki Stezenie kationow Zakres: lit (5,0 – 1000) mg/dm3 sod (5,0 – 1000) mg/dm3 jon amonowy (0,15 – 10) mg/dm3 potas (5,0 – 500) mg/dm3 magnez (5,0 – 500) mg/dm3 wapn (5,0 – 1000) mg/dm3 azot amonowy (0,12 – 7,78) mg/dm3 Metoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 14911:2002","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Cation concentration Range: lithium (5,0 – 1000) mg/dm3 sodium (5,0 – 1000) mg/dm3 ammonium ion (0,15 – 10) mg/dm3 potassium (5,0 – 500) mg/dm3 magnesium (5,0 – 500) mg/dm3 calcium (5,0 – 1000) mg/dm3 ammonium nitrogen (0,12 – 7,78) mg/dm3 Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 14911:2002","search_zh":"水、废水 PN-EN ISO 14911:2002","test_object_zh":"水、废水"},{"_id":"6a5a55f49af9f73f382519a1","lab_id":"69ad52a3de79e566650fb664","country":"PL","accr_number":"AB 1249","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"pH Zakres: 3,0 – 12,0 Metoda potencjometryczna","methodology_en":"pH Range: 3,0 – 12,0 Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH Zakres: 3,0 – 12,0 Metoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki pH Zakres: 3,0 – 12,0 Metoda potencjometryczna PN-EN ISO 10523:2012 Woda, scieki pH Zakres: 3,0 – 12,0 Metoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater pH Range: 3,0 – 12,0 Potentiometric method PN-EN ISO 10523:2012","search_zh":"水、废水 pH 范围：3,0 – 12,0 电位法 PN-EN ISO 10523:2012","test_object_zh":"水、废水","methodology_zh":"pH 范围：3,0 – 12,0 电位法"},{"_id":"6a5a55f49af9f73f382519a2","lab_id":"69ad52a3de79e566650fb664","country":"PL","accr_number":"AB 1249","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Przewodność elektryczna właściwa Zakres: (10 – 50000) µS/cm Metoda konduktometryczna","methodology_en":"Electrical conductivity Range: (10 – 50000) µS/cm Conductometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa Zakres: (10 – 50000) µS/cm Metoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Przewodność elektryczna właściwa Zakres: (10 – 50000) µS/cm Metoda konduktometryczna PN-EN 27888:1999 Woda, scieki Przewodnosc elektryczna wlasciwa Zakres: (10 – 50000) µS/cm Metoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Electrical conductivity Range: (10 – 50000) µS/cm Conductometric method PN-EN 27888:1999","search_zh":"水、废水 PN-EN 27888:1999","test_object_zh":"水、废水"},{"_id":"6a5a55f49af9f73f382519a3","lab_id":"69ad52a3de79e566650fb664","country":"PL","accr_number":"AB 1249","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA) Zakres: - benzo(a)antracen (3,0 – 1000) ng/dm3 - chryzen (3,0 – 1000) ng/dm3 - benzo(b)fluoranten (3,0 – 1000) ng/dm3 - benzo(k)fluoranten (3,0 – 1000) ng/dm3 - benzo(a)piren (3,0 – 1000) ng/dm3 - dibenzo(a,h)antracen (3,0 – 1000) ng/dm3 - benzo(g,h,i)perylen (3,0 – 1000) ng/dm3 - Indeno(1,2,3-cd)piren (3,0 – 1000) ng/dm3 Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) Suma WWA: (z obliczeń)","methodology_en":"Concentration of polycyclic aromatic hydrocarbons (PAH) Range: - benzo(a)anthracene (3,0 – 1000) ng/dm3 - chrysene (3,0 – 1000) ng/dm3 - benzo(b)fluoranthene (3,0 – 1000) ng/dm3 - benzo(k)fluoranthene (3,0 – 1000) ng/dm3 - benzo(a)pyrene (3,0 – 1000) ng/dm3 - dibenzo(a,h)anthracene (3,0 – 1000) ng/dm3 - benzo(g,h,i)perylene (3,0 – 1000) ng/dm3 - Indeno(1,2,3-cd)pyrene (3,0 – 1000) ng/dm3 High performance liquid chromatography method with fluorescence detection (HPLC-FLD) Sum of PAH: (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA) Zakres: - benzo(a)antracen (3,0 – 1000) ng/dm3 - chryzen (3,0 – 1000) ng/dm3 - benzo(b)fluoranten (3,0 – 1000) ng/dm3 - benzo(k)fluoranten (3,0 – 1000) ng/dm3 - benzo(a)piren (3,0 – 1000) ng/dm3 - dibenzo(a,h)antracen (3,0 – 1000) ng/dm3 - benzo(g,h,i)perylen (3,0 – 1000) ng/dm3 - Indeno(1,2,3-cd)piren (3,0 – 1000) ng/dm3 Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) Suma WWA: (z obliczeń)","reference":"PN-EN ISO 17993:2005","norm_bases":["PN-EN ISO 17993:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA) Zakres: - benzo(a)antracen (3,0 – 1000) ng/dm3 - chryzen (3,0 – 1000) ng/dm3 - benzo(b)fluoranten (3,0 – 1000) ng/dm3 - benzo(k)fluoranten (3,0 – 1000) ng/dm3 - benzo(a)piren (3,0 – 1000) ng/dm3 - dibenzo(a,h)antracen (3,0 – 1000) ng/dm3 - benzo(g,h,i)perylen (3,0 – 1000) ng/dm3 - Indeno(1,2,3-cd)piren (3,0 – 1000) ng/dm3 Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) Suma WWA: (z obliczeń) PN-EN ISO 17993:2005 Woda, scieki Stezenie wielopierscieniowych weglowodorow aromatycznych (WWA) Zakres: - benzo(a)antracen (3,0 – 1000) ng/dm3 - chryzen (3,0 – 1000) ng/dm3 - benzo(b)fluoranten (3,0 – 1000) ng/dm3 - benzo(k)fluoranten (3,0 – 1000) ng/dm3 - benzo(a)piren (3,0 – 1000) ng/dm3 - dibenzo(a,h)antracen (3,0 – 1000) ng/dm3 - benzo(g,h,i)perylen (3,0 – 1000) ng/dm3 - Indeno(1,2,3-cd)piren (3,0 – 1000) ng/dm3 Metoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) Suma WWA: (z obliczen) PN-EN ISO 17993:2005","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Concentration of polycyclic aromatic hydrocarbons (PAH) Range: - benzo(a)anthracene (3,0 – 1000) ng/dm3 - chrysene (3,0 – 1000) ng/dm3 - benzo(b)fluoranthene (3,0 – 1000) ng/dm3 - benzo(k)fluoranthene (3,0 – 1000) ng/dm3 - benzo(a)pyrene (3,0 – 1000) ng/dm3 - dibenzo(a,h)anthracene (3,0 – 1000) ng/dm3 - benzo(g,h,i)perylene (3,0 – 1000) ng/dm3 - Indeno(1,2,3-cd)pyrene (3,0 – 1000) ng/dm3 High performance liquid chromatography method with fluorescence detection (HPLC-FLD) Sum of PAH: (calculated) PN-EN ISO 17993:2005","search_zh":"水、废水 PN-EN ISO 17993:2005","test_object_zh":"水、废水"},{"_id":"6a5a55f49af9f73f382519a4","lab_id":"69ad52a3de79e566650fb664","country":"PL","accr_number":"AB 1249","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Zawiesiny ogólne Zakres: (2,0 – 4000) mg/dm3 Metoda wagowa","methodology_en":"Total suspended solids Range: (2,0 – 4000) mg/dm3 Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawiesiny ogólne Zakres: (2,0 – 4000) mg/dm3 Metoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Zawiesiny ogólne Zakres: (2,0 – 4000) mg/dm3 Metoda wagowa PN-EN 872:2007+Ap1:2007 Woda, scieki Zawiesiny ogolne Zakres: (2,0 – 4000) mg/dm3 Metoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Total suspended solids Range: (2,0 – 4000) mg/dm3 Gravimetric method PN-EN 872:2007+Ap1:2007","search_zh":"水、废水 PN-EN 872:2007+Ap1:2007","test_object_zh":"水、废水"},{"_id":"6a5a55f49af9f73f382519a5","lab_id":"69ad52a3de79e566650fb664","country":"PL","accr_number":"AB 1249","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie fosforu ogólnego Zakres: (0,020 – 50,0) mg/dm3 Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","methodology_en":"Total phosphorus concentration Range: (0,020 – 50,0) mg/dm3 Inductively coupled plasma optical emission spectrometry (ICP-OES)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego Zakres: (0,020 – 50,0) mg/dm3 Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie fosforu ogólnego Zakres: (0,020 – 50,0) mg/dm3 Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Woda, scieki Stezenie fosforu ogolnego Zakres: (0,020 – 50,0) mg/dm3 Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Total phosphorus concentration Range: (0,020 – 50,0) mg/dm3 Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009","search_zh":"水、废水 PN-EN ISO 11885:2009","test_object_zh":"水、废水"},{"_id":"6a5a55f49af9f73f382519a6","lab_id":"69ad52a3de79e566650fb664","country":"PL","accr_number":"AB 1249","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie rtęci Zakres: (0,0040 – 5,0) mg/dm3 Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","methodology_en":"Mercury concentration Range: (0,0040 – 5,0) mg/dm3 Inductively coupled plasma optical emission spectrometry (ICP-OES)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie rtęci Zakres: (0,0040 – 5,0) mg/dm3 Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie rtęci Zakres: (0,0040 – 5,0) mg/dm3 Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Woda, scieki Stezenie rteci Zakres: (0,0040 – 5,0) mg/dm3 Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Mercury concentration Range: (0,0040 – 5,0) mg/dm3 Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009","search_zh":"水、废水 PN-EN ISO 11885:2009","test_object_zh":"水、废水"},{"_id":"6a5a55f49af9f73f382519a7","lab_id":"69ad52a3de79e566650fb664","country":"PL","accr_number":"AB 1249","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-11:2017-10 z wyłączeniem pkt. 5.2 | PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5 | PN-ISO 5667-4:2017-10 z wyłączeniem pkt. 13","norm_bases":["PN-ISO 5667-11:2017-10 z wyłączeniem pkt. 5.2","PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5","PN-ISO 5667-4:2017-10 z wyłączeniem pkt. 13"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-11:2017-10 z wyłączeniem pkt. 5.2 | PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5 | PN-ISO 5667-4:2017-10 z wyłączeniem pkt. 13 Woda Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-11:2017-10 z wylaczeniem pkt. 5.2 | PN-EN ISO 5667-6:2016-12 z wylaczeniem pkt. 7.5 | PN-ISO 5667-4:2017-10 z wylaczeniem pkt. 13","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Sampling for chemical and physical testing PN-ISO 5667-11:2017-10 z wyłączeniem pkt. 5.2 | PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5 | PN-ISO 5667-4:2017-10 z wyłączeniem pkt. 13","methodology_zh":"化学与物理检测用样品采集","search_zh":"水 化学与物理检测用样品采集 PN-ISO 5667-11:2017-10 z wyłączeniem pkt. 5.2 | PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5 | PN-ISO 5667-4:2017-10 z wyłączeniem pkt. 13","test_object_zh":"水"},{"_id":"6a5a55f49af9f73f382519a8","lab_id":"69ad52a3de79e566650fb664","country":"PL","accr_number":"AB 1249","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie rtęci Zakres: (0,0010 – 0,050) mg/dm3 Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)","methodology_en":"Mercury concentration Range: (0,0010 – 0,050) mg/dm3 Inductively coupled plasma optical emission spectrometry with hydride generation (HG-ICP-OES)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie rtęci Zakres: (0,0010 – 0,050) mg/dm3 Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie rtęci Zakres: (0,0010 – 0,050) mg/dm3 Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES) PN-EN ISO 11885:2009 Woda Stezenie rteci Zakres: (0,0010 – 0,050) mg/dm3 Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej z generowaniem wodorkow (HG-ICP-OES) PN-EN ISO 11885:2009","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Mercury concentration Range: (0,0010 – 0,050) mg/dm3 Inductively coupled plasma optical emission spectrometry with hydride generation (HG-ICP-OES) PN-EN ISO 11885:2009","search_zh":"水 PN-EN ISO 11885:2009","test_object_zh":"水"},{"_id":"6a5a55f49af9f73f382519a9","lab_id":"69ad52a3de79e566650fb664","country":"PL","accr_number":"AB 1249","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna","methodology_en":"Sampling for chemical and physical testing Manual method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych Metoda manualna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Sampling for chemical and physical testing Manual method PN-ISO 5667-10:2021-11","search_zh":"污水 用于化学与物理检验的采样 手工法 PN-ISO 5667-10:2021-11","test_object_zh":"污水","methodology_zh":"用于化学与物理检验的采样 手工法"},{"_id":"6a5a55f49af9f73f382519aa","lab_id":"69ad52a3de79e566650fb664","country":"PL","accr_number":"AB 1249","accr_body":"PCA","test_object":"Odpady O): kod 01 01 02, 01 04 08, 01 04 09, 02 03 99, 04 02 09, 04 02 20, 07 01 99, 10 12 05, 12 01 03, 12 01 21, 16 03 06, 16 81 02, 17 05 03, 17 05 07, 17 05 08, 17 06 04, 17 09 04, 19 06 06, 19 08 01, 19 08 12, 19 08 14, 19 12 09, 19 12 12, 19 13 02 01 04 10, 01 04 12, 10 01 02, 10 01 20, 10 01 21, 10 02 01, 10 09 07, 10 09 08, 10 09 11, 10 09 12, 10 10 12, 10 10 11, 10 12 03, 10 12 08, 10 13 06, 12 01 17, 17 01 81","test_object_en":"Waste O): code 01 01 02, 01 04 08, 01 04 09, 02 03 99, 04 02 09, 04 02 20, 07 01 99, 10 12 05, 12 01 03, 12 01 21, 16 03 06, 16 81 02, 17 05 03, 17 05 07, 17 05 08, 17 06 04, 17 09 04, 19 06 06, 19 08 01, 19 08 12, 19 08 14, 19 12 09, 19 12 12, 19 13 02 01 04 10, 01 04 12, 10 01 02, 10 01 20, 10 01 21, 10 02 01, 10 09 07, 10 09 08, 10 09 11, 10 09 12, 10 10 12, 10 10 11, 10 12 03, 10 12 08, 10 13 06, 12 01 17, 17 01 81","methodology":"Zawartość anionów Zakres: fluorki (1,0 – 1000) mg/kg chlorki (2,0 – 100000) mg/kg siarczany (2,0 – 100000) mg/kg Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","methodology_en":"Anion content Range: fluorides (1,0 – 1000) mg/kg chlorides (2,0 – 100000) mg/kg sulphates (2,0 – 100000) mg/kg Ion chromatography method with conductometric detection (IC-CD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość anionów Zakres: fluorki (1,0 – 1000) mg/kg chlorki (2,0 – 100000) mg/kg siarczany (2,0 – 100000) mg/kg Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN 12457-2:2006 PN-EN ISO 10304-1:2009","norm_bases":["PN-EN 12457-2:2006 PN-EN ISO 10304-1:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O): kod 01 01 02, 01 04 08, 01 04 09, 02 03 99, 04 02 09, 04 02 20, 07 01 99, 10 12 05, 12 01 03, 12 01 21, 16 03 06, 16 81 02, 17 05 03, 17 05 07, 17 05 08, 17 06 04, 17 09 04, 19 06 06, 19 08 01, 19 08 12, 19 08 14, 19 12 09, 19 12 12, 19 13 02 01 04 10, 01 04 12, 10 01 02, 10 01 20, 10 01 21, 10 02 01, 10 09 07, 10 09 08, 10 09 11, 10 09 12, 10 10 12, 10 10 11, 10 12 03, 10 12 08, 10 13 06, 12 01 17, 17 01 81 Zawartość anionów Zakres: fluorki (1,0 – 1000) mg/kg chlorki (2,0 – 100000) mg/kg siarczany (2,0 – 100000) mg/kg Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN 12457-2:2006 PN-EN ISO 10304-1:2009 Odpady O): kod 01 01 02, 01 04 08, 01 04 09, 02 03 99, 04 02 09, 04 02 20, 07 01 99, 10 12 05, 12 01 03, 12 01 21, 16 03 06, 16 81 02, 17 05 03, 17 05 07, 17 05 08, 17 06 04, 17 09 04, 19 06 06, 19 08 01, 19 08 12, 19 08 14, 19 12 09, 19 12 12, 19 13 02 01 04 10, 01 04 12, 10 01 02, 10 01 20, 10 01 21, 10 02 01, 10 09 07, 10 09 08, 10 09 11, 10 09 12, 10 10 12, 10 10 11, 10 12 03, 10 12 08, 10 13 06, 12 01 17, 17 01 81 Zawartosc anionow Zakres: fluorki (1,0 – 1000) mg/kg chlorki (2,0 – 100000) mg/kg siarczany (2,0 – 100000) mg/kg Metoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN 12457-2:2006 PN-EN ISO 10304-1:2009","categories":["environment"],"row_index":16,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste O): code 01 01 02, 01 04 08, 01 04 09, 02 03 99, 04 02 09, 04 02 20, 07 01 99, 10 12 05, 12 01 03, 12 01 21, 16 03 06, 16 81 02, 17 05 03, 17 05 07, 17 05 08, 17 06 04, 17 09 04, 19 06 06, 19 08 01, 19 08 12, 19 08 14, 19 12 09, 19 12 12, 19 13 02 01 04 10, 01 04 12, 10 01 02, 10 01 20, 10 01 21, 10 02 01, 10 09 07, 10 09 08, 10 09 11, 10 09 12, 10 10 12, 10 10 11, 10 12 03, 10 12 08, 10 13 06, 12 01 17, 17 01 81 Anion content Range: fluorides (1,0 – 1000) mg/kg chlorides (2,0 – 100000) mg/kg sulphates (2,0 – 100000) mg/kg Ion chromatography method with conductometric detection (IC-CD) PN-EN 12457-2:2006 PN-EN ISO 10304-1:2009"},{"_id":"6a5a55f49af9f73f382519ab","lab_id":"69ad52a3de79e566650fb664","country":"PL","accr_number":"AB 1249","accr_body":"PCA","test_object":"Odpady O): kod 01 04 08, 01 04 10, 01 04 12, 10 01 02, 10 01 20, 10 01 21, 10 02 01, 10 09 07, 10 09 08, 10 09 11, 10 09 12, 10 10 12, 10 10 11, 10 12 03, 10 12 08, 10 13 06, 12 01 17, 17 01 81","test_object_en":"Waste O): code 01 04 08, 01 04 10, 01 04 12, 10 01 02, 10 01 20, 10 01 21, 10 02 01, 10 09 07, 10 09 08, 10 09 11, 10 09 12, 10 10 12, 10 10 11, 10 12 03, 10 12 08, 10 13 06, 12 01 17, 17 01 81","methodology":"Zawartość pierwiastków Zakres: arsen (0,10 – 500,0) mg/kg molibden (0,020 – 500,0) mg/kg kadm (0,020 – 500,0) mg/kg ołów (0,040 – 500,0) mg/kg nikiel (0,020 – 500,0) mg/kg chrom (0,020 – 500,0) mg/kg miedź (0,020 – 500,0) mg/kg bar (0,020 – 500,0) mg/kg rtęć (0,040 – 50,0) mg/kg cynk (0,10 – 100,0) mg/kg selen (0,060 – 500,0) mg/kg antymon (0,060 – 500,0) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","methodology_en":"Content of elements Range: arsenic (0,10 – 500,0) mg/kg molybdenum (0,020 – 500,0) mg/kg cadmium (0,020 – 500,0) mg/kg lead (0,040 – 500,0) mg/kg nickel (0,020 – 500,0) mg/kg chromium (0,020 – 500,0) mg/kg copper (0,020 – 500,0) mg/kg barium (0,020 – 500,0) mg/kg mercury (0,040 – 50,0) mg/kg zinc (0,10 – 100,0) mg/kg selenium (0,060 – 500,0) mg/kg antimony (0,060 – 500,0) mg/kg Inductively coupled plasma atomic emission spectrometry (ICP-OES) method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość pierwiastków Zakres: arsen (0,10 – 500,0) mg/kg molibden (0,020 – 500,0) mg/kg kadm (0,020 – 500,0) mg/kg ołów (0,040 – 500,0) mg/kg nikiel (0,020 – 500,0) mg/kg chrom (0,020 – 500,0) mg/kg miedź (0,020 – 500,0) mg/kg bar (0,020 – 500,0) mg/kg rtęć (0,040 – 50,0) mg/kg cynk (0,10 – 100,0) mg/kg selen (0,060 – 500,0) mg/kg antymon (0,060 – 500,0) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN 12457-2:2006 PN-EN ISO 11885:2009","norm_bases":["PN-EN 12457-2:2006 PN-EN ISO 11885:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O): kod 01 04 08, 01 04 10, 01 04 12, 10 01 02, 10 01 20, 10 01 21, 10 02 01, 10 09 07, 10 09 08, 10 09 11, 10 09 12, 10 10 12, 10 10 11, 10 12 03, 10 12 08, 10 13 06, 12 01 17, 17 01 81 Zawartość pierwiastków Zakres: arsen (0,10 – 500,0) mg/kg molibden (0,020 – 500,0) mg/kg kadm (0,020 – 500,0) mg/kg ołów (0,040 – 500,0) mg/kg nikiel (0,020 – 500,0) mg/kg chrom (0,020 – 500,0) mg/kg miedź (0,020 – 500,0) mg/kg bar (0,020 – 500,0) mg/kg rtęć (0,040 – 50,0) mg/kg cynk (0,10 – 100,0) mg/kg selen (0,060 – 500,0) mg/kg antymon (0,060 – 500,0) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN 12457-2:2006 PN-EN ISO 11885:2009 Odpady O): kod 01 04 08, 01 04 10, 01 04 12, 10 01 02, 10 01 20, 10 01 21, 10 02 01, 10 09 07, 10 09 08, 10 09 11, 10 09 12, 10 10 12, 10 10 11, 10 12 03, 10 12 08, 10 13 06, 12 01 17, 17 01 81 Zawartosc pierwiastkow Zakres: arsen (0,10 – 500,0) mg/kg molibden (0,020 – 500,0) mg/kg kadm (0,020 – 500,0) mg/kg olow (0,040 – 500,0) mg/kg nikiel (0,020 – 500,0) mg/kg chrom (0,020 – 500,0) mg/kg miedz (0,020 – 500,0) mg/kg bar (0,020 – 500,0) mg/kg rtec (0,040 – 50,0) mg/kg cynk (0,10 – 100,0) mg/kg selen (0,060 – 500,0) mg/kg antymon (0,060 – 500,0) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN 12457-2:2006 PN-EN ISO 11885:2009","categories":["environment","materials"],"row_index":17,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste O): code 01 04 08, 01 04 10, 01 04 12, 10 01 02, 10 01 20, 10 01 21, 10 02 01, 10 09 07, 10 09 08, 10 09 11, 10 09 12, 10 10 12, 10 10 11, 10 12 03, 10 12 08, 10 13 06, 12 01 17, 17 01 81 Content of elements Range: arsenic (0,10 – 500,0) mg/kg molybdenum (0,020 – 500,0) mg/kg cadmium (0,020 – 500,0) mg/kg lead (0,040 – 500,0) mg/kg nickel (0,020 – 500,0) mg/kg chromium (0,020 – 500,0) mg/kg copper (0,020 – 500,0) mg/kg barium (0,020 – 500,0) mg/kg mercury (0,040 – 50,0) mg/kg zinc (0,10 – 100,0) mg/kg selenium (0,060 – 500,0) mg/kg antimony (0,060 – 500,0) mg/kg Inductively coupled plasma atomic emission spectrometry (ICP-OES) method PN-EN 12457-2:2006 PN-EN ISO 11885:2009"},{"_id":"6a5a55f49af9f73f382519ac","lab_id":"69ad52a3de79e566650fb664","country":"PL","accr_number":"AB 1249","accr_body":"PCA","test_object":"Odpady O): kod 01 04 08, 01 04 10, 01 04 12, 10 01 02, 10 01 20, 10 01 21, 10 02 01, 10 09 07, 10 09 08, 10 09 11, 10 09 12, 10 10 12, 10 10 11, 10 12 03, 10 12 08, 10 13 06, 12 01 17, 17 01 81","test_object_en":"Waste O): code 01 04 08, 01 04 10, 01 04 12, 10 01 02, 10 01 20, 10 01 21, 10 02 01, 10 09 07, 10 09 08, 10 09 11, 10 09 12, 10 10 12, 10 10 11, 10 12 03, 10 12 08, 10 13 06, 12 01 17, 17 01 81","methodology":"Zawartość pierwiastków Zakres: rtęć (0,010 – 0,50) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)","methodology_en":"Content of elements Range: mercury (0,010 – 0,50) mg/kg Hydride generation inductively coupled plasma atomic emission spectrometry (HG-ICP-OES) method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość pierwiastków Zakres: rtęć (0,010 – 0,50) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)","reference":"PN-EN 12457-2:2006 PN-EN ISO 11885:2009","norm_bases":["PN-EN 12457-2:2006 PN-EN ISO 11885:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O): kod 01 04 08, 01 04 10, 01 04 12, 10 01 02, 10 01 20, 10 01 21, 10 02 01, 10 09 07, 10 09 08, 10 09 11, 10 09 12, 10 10 12, 10 10 11, 10 12 03, 10 12 08, 10 13 06, 12 01 17, 17 01 81 Zawartość pierwiastków Zakres: rtęć (0,010 – 0,50) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES) PN-EN 12457-2:2006 PN-EN ISO 11885:2009 Odpady O): kod 01 04 08, 01 04 10, 01 04 12, 10 01 02, 10 01 20, 10 01 21, 10 02 01, 10 09 07, 10 09 08, 10 09 11, 10 09 12, 10 10 12, 10 10 11, 10 12 03, 10 12 08, 10 13 06, 12 01 17, 17 01 81 Zawartosc pierwiastkow Zakres: rtec (0,010 – 0,50) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej z generowaniem wodorkow (HG-ICP-OES) PN-EN 12457-2:2006 PN-EN ISO 11885:2009","categories":["environment"],"row_index":18,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste O): code 01 04 08, 01 04 10, 01 04 12, 10 01 02, 10 01 20, 10 01 21, 10 02 01, 10 09 07, 10 09 08, 10 09 11, 10 09 12, 10 10 12, 10 10 11, 10 12 03, 10 12 08, 10 13 06, 12 01 17, 17 01 81 Content of elements Range: mercury (0,010 – 0,50) mg/kg Hydride generation inductively coupled plasma atomic emission spectrometry (HG-ICP-OES) method PN-EN 12457-2:2006 PN-EN ISO 11885:2009"},{"_id":"6a5a55f49af9f73f382519ad","lab_id":"69ad52a3de79e566650fb664","country":"PL","accr_number":"AB 1249","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Zawartość węglowodorów monoaromatycznych Zakres: benzen (0,10 – 20) mg/kg toluen (0,10 – 20) mg/kg etylobenzen (0,10 – 20) mg/kg m+p-ksylen (0,10 – 40) mg/kg o-ksylen (0,10 – 20) mg/kg Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","methodology_en":"Content of monoaromatic hydrocarbons Range: benzene (0,10 – 20) mg/kg toluene (0,10 – 20) mg/kg ethylbenzene (0,10 – 20) mg/kg m+p-xylene (0,10 – 40) mg/kg o-xylene (0,10 – 20) mg/kg Gas chromatography with flame ionization detection (GC-FID) method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość węglowodorów monoaromatycznych Zakres: benzen (0,10 – 20) mg/kg toluen (0,10 – 20) mg/kg etylobenzen (0,10 – 20) mg/kg m+p-ksylen (0,10 – 40) mg/kg o-ksylen (0,10 – 20) mg/kg Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Procedura badawcza PB-1 wydanie 4 z dnia 17.12.2019 r.","norm_bases":["Procedura badawcza PB-1 wydanie 4 z dnia 17.12.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Zawartość węglowodorów monoaromatycznych Zakres: benzen (0,10 – 20) mg/kg toluen (0,10 – 20) mg/kg etylobenzen (0,10 – 20) mg/kg m+p-ksylen (0,10 – 40) mg/kg o-ksylen (0,10 – 20) mg/kg Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Procedura badawcza PB-1 wydanie 4 z dnia 17.12.2019 r. Gleba Zawartosc weglowodorow monoaromatycznych Zakres: benzen (0,10 – 20) mg/kg toluen (0,10 – 20) mg/kg etylobenzen (0,10 – 20) mg/kg m+p-ksylen (0,10 – 40) mg/kg o-ksylen (0,10 – 20) mg/kg Metoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Procedura badawcza PB-1 wydanie 4 z dnia 17.12.2019 r.","categories":["environment"],"row_index":19,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil Content of monoaromatic hydrocarbons Range: benzene (0,10 – 20) mg/kg toluene (0,10 – 20) mg/kg ethylbenzene (0,10 – 20) mg/kg m+p-xylene (0,10 – 40) mg/kg o-xylene (0,10 – 20) mg/kg Gas chromatography with flame ionization detection (GC-FID) method Procedura badawcza PB-1 wydanie 4 z dnia 17.12.2019 r.","search_zh":"土壤 Procedura badawcza PB-1 wydanie 4 z dnia 17.12.2019 r.","test_object_zh":"土壤"},{"_id":"6a5a55f49af9f73f382519ae","lab_id":"69ad52a3de79e566650fb664","country":"PL","accr_number":"AB 1249","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Zawartość węglowodorów ropopochodnych Zakres: Benzyna C6-C12 (0,30 – 10000) mg/kg Olej C12-C35 (8,0 – 10000) mg/kg Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Zawartość węglowodorów ropopochodnych C6-C35 (z obliczeń)","methodology_en":"Content of petroleum hydrocarbons Range: Petrol C6-C12 (0,30 – 10000) mg/kg Oil C12-C35 (8,0 – 10000) mg/kg Gas chromatography with flame ionization detection (GC-FID) method Content of petroleum hydrocarbons C6-C35 (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość węglowodorów ropopochodnych Zakres: Benzyna C6-C12 (0,30 – 10000) mg/kg Olej C12-C35 (8,0 – 10000) mg/kg Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Zawartość węglowodorów ropopochodnych C6-C35 (z obliczeń)","reference":"Procedura badawcza PB-1 wydanie 4 z dnia 17.12.2019 r.","norm_bases":["Procedura badawcza PB-1 wydanie 4 z dnia 17.12.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Zawartość węglowodorów ropopochodnych Zakres: Benzyna C6-C12 (0,30 – 10000) mg/kg Olej C12-C35 (8,0 – 10000) mg/kg Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Zawartość węglowodorów ropopochodnych C6-C35 (z obliczeń) Procedura badawcza PB-1 wydanie 4 z dnia 17.12.2019 r. Gleba Zawartosc weglowodorow ropopochodnych Zakres: Benzyna C6-C12 (0,30 – 10000) mg/kg Olej C12-C35 (8,0 – 10000) mg/kg Metoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Zawartosc weglowodorow ropopochodnych C6-C35 (z obliczen) Procedura badawcza PB-1 wydanie 4 z dnia 17.12.2019 r.","categories":["petro","environment"],"row_index":20,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil Content of petroleum hydrocarbons Range: Petrol C6-C12 (0,30 – 10000) mg/kg Oil C12-C35 (8,0 – 10000) mg/kg Gas chromatography with flame ionization detection (GC-FID) method Content of petroleum hydrocarbons C6-C35 (calculated) Procedura badawcza PB-1 wydanie 4 z dnia 17.12.2019 r.","search_zh":"土壤 Procedura badawcza PB-1 wydanie 4 z dnia 17.12.2019 r.","test_object_zh":"土壤"},{"_id":"6a5a55f49af9f73f382519af","lab_id":"69ad52a3de79e566650fb664","country":"PL","accr_number":"AB 1249","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Sucha masa Zakres: (0,1 – 99,9) % Metoda wagowa","methodology_en":"Dry matter Range: (0,1 – 99,9) % Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Sucha masa Zakres: (0,1 – 99,9) % Metoda wagowa","reference":"PN-ISO 11465:1999","norm_bases":["PN-ISO 11465:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Sucha masa Zakres: (0,1 – 99,9) % Metoda wagowa PN-ISO 11465:1999 Gleba Sucha masa Zakres: (0,1 – 99,9) % Metoda wagowa PN-ISO 11465:1999","categories":["environment"],"row_index":21,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil Dry matter Range: (0,1 – 99,9) % Gravimetric method PN-ISO 11465:1999","search_zh":"土壤 PN-ISO 11465:1999","test_object_zh":"土壤"},{"_id":"6a5a55f49af9f73f382519b0","lab_id":"69ad52a3de79e566650fb664","country":"PL","accr_number":"AB 1249","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Przewodność elektryczna właściwa Zakres: (10 – 50000) µS/cm Metoda konduktometryczna","methodology_en":"Electrical conductivity Range: (10 – 50000) µS/cm Conductometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa Zakres: (10 – 50000) µS/cm Metoda konduktometryczna","reference":"PN-ISO 11265+AC1:1997","norm_bases":["PN-ISO 11265+AC1:1997"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Przewodność elektryczna właściwa Zakres: (10 – 50000) µS/cm Metoda konduktometryczna PN-ISO 11265+AC1:1997 Gleba Przewodnosc elektryczna wlasciwa Zakres: (10 – 50000) µS/cm Metoda konduktometryczna PN-ISO 11265+AC1:1997","categories":["environment"],"row_index":22,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil Electrical conductivity Range: (10 – 50000) µS/cm Conductometric method PN-ISO 11265+AC1:1997","search_zh":"土壤 PN-ISO 11265+AC1:1997","test_object_zh":"土壤"},{"_id":"6a5a55f49af9f73f382519b1","lab_id":"69ad52a3de79e566650fb664","country":"PL","accr_number":"AB 1249","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA) Zakres: Naftalen (0,015 – 1000) mg/kg Acenaftylen (10 – 1000) mg/kg Acenaften (10 – 1000) mg/kg Fluoren (0,50 – 1000) mg/kg Fenantren (0,010 – 500) mg/kg Antracen (0,010 – 1000) mg/kg Fluoranten (0,050 – 500) mg/kg Piren (0,010 – 500) mg/kg Benzo(a)antracen (0,010 – 500) mg/kg Chryzen (0,010 – 500) mg/kg Benzo(b)fluoranten (0,010 – 500) mg/kg Benzo(k)fluoranten (0,010 – 500) mg/kg Benzo(a)piren (0,0060 – 500) mg/kg Dibenzo(a,h)antracen (0,010 – 500) mg/kg Benzo(g,h,i)perylen (0,010 – 500) mg/kg Indeno(1,2,3-cd)piren (0,010 – 500) mg/kg Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) oraz z detekcją UV (HPLC-UV) Suma WWA (z obliczeń)","methodology_en":"Content of polycyclic aromatic hydrocarbons (PAH) Range: Naphthalene (0,015 – 1000) mg/kg Acenaphthylene (10 – 1000) mg/kg Acenaphthene (10 – 1000) mg/kg Fluorene (0,50 – 1000) mg/kg Phenanthrene (0,010 – 500) mg/kg Anthracene (0,010 – 1000) mg/kg Fluoranthene (0,050 – 500) mg/kg Pyrene (0,010 – 500) mg/kg Benzo(a)anthracene (0,010 – 500) mg/kg Chrysene (0,010 – 500) mg/kg Benzo(b)fluoranthene (0,010 – 500) mg/kg Benzo(k)fluoranthene (0,010 – 500) mg/kg Benzo(a)pyrene (0,0060 – 500) mg/kg Dibenzo(a,h)anthracene (0,010 – 500) mg/kg Benzo(g,h,i)perylene (0,010 – 500) mg/kg Indeno(1,2,3-cd)pyrene (0,010 – 500) mg/kg High performance liquid chromatography with fluorescence detection (HPLC-FLD) and with UV detection (HPLC-UV) method Sum of PAH (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA) Zakres: Naftalen (0,015 – 1000) mg/kg Acenaftylen (10 – 1000) mg/kg Acenaften (10 – 1000) mg/kg Fluoren (0,50 – 1000) mg/kg Fenantren (0,010 – 500) mg/kg Antracen (0,010 – 1000) mg/kg Fluoranten (0,050 – 500) mg/kg Piren (0,010 – 500) mg/kg Benzo(a)antracen (0,010 – 500) mg/kg Chryzen (0,010 – 500) mg/kg Benzo(b)fluoranten (0,010 – 500) mg/kg Benzo(k)fluoranten (0,010 – 500) mg/kg Benzo(a)piren (0,0060 – 500) mg/kg Dibenzo(a,h)antracen (0,010 – 500) mg/kg Benzo(g,h,i)perylen (0,010 – 500) mg/kg Indeno(1,2,3-cd)piren (0,010 – 500) mg/kg Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) oraz z detekcją UV (HPLC-UV) Suma WWA (z obliczeń)","reference":"PN-ISO 13877:2004 z wyłączeniem pkt. 7 Instrukcja I-13 wydanie 4 z dnia 17.12.2019 r.","norm_bases":["PN-ISO 13877:2004 z wyłączeniem pkt. 7 Instrukcja I-13 wydanie 4 z dnia 17.12.2019 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA) Zakres: Naftalen (0,015 – 1000) mg/kg Acenaftylen (10 – 1000) mg/kg Acenaften (10 – 1000) mg/kg Fluoren (0,50 – 1000) mg/kg Fenantren (0,010 – 500) mg/kg Antracen (0,010 – 1000) mg/kg Fluoranten (0,050 – 500) mg/kg Piren (0,010 – 500) mg/kg Benzo(a)antracen (0,010 – 500) mg/kg Chryzen (0,010 – 500) mg/kg Benzo(b)fluoranten (0,010 – 500) mg/kg Benzo(k)fluoranten (0,010 – 500) mg/kg Benzo(a)piren (0,0060 – 500) mg/kg Dibenzo(a,h)antracen (0,010 – 500) mg/kg Benzo(g,h,i)perylen (0,010 – 500) mg/kg Indeno(1,2,3-cd)piren (0,010 – 500) mg/kg Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) oraz z detekcją UV (HPLC-UV) Suma WWA (z obliczeń) PN-ISO 13877:2004 z wyłączeniem pkt. 7 Instrukcja I-13 wydanie 4 z dnia 17.12.2019 r. Gleba Zawartosc wielopierscieniowych weglowodorow aromatycznych (WWA) Zakres: Naftalen (0,015 – 1000) mg/kg Acenaftylen (10 – 1000) mg/kg Acenaften (10 – 1000) mg/kg Fluoren (0,50 – 1000) mg/kg Fenantren (0,010 – 500) mg/kg Antracen (0,010 – 1000) mg/kg Fluoranten (0,050 – 500) mg/kg Piren (0,010 – 500) mg/kg Benzo(a)antracen (0,010 – 500) mg/kg Chryzen (0,010 – 500) mg/kg Benzo(b)fluoranten (0,010 – 500) mg/kg Benzo(k)fluoranten (0,010 – 500) mg/kg Benzo(a)piren (0,0060 – 500) mg/kg Dibenzo(a,h)antracen (0,010 – 500) mg/kg Benzo(g,h,i)perylen (0,010 – 500) mg/kg Indeno(1,2,3-cd)piren (0,010 – 500) mg/kg Metoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) oraz z detekcja UV (HPLC-UV) Suma WWA (z obliczen) PN-ISO 13877:2004 z wylaczeniem pkt. 7 Instrukcja I-13 wydanie 4 z dnia 17.12.2019 r.","categories":["environment"],"row_index":23,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil Content of polycyclic aromatic hydrocarbons (PAH) Range: Naphthalene (0,015 – 1000) mg/kg Acenaphthylene (10 – 1000) mg/kg Acenaphthene (10 – 1000) mg/kg Fluorene (0,50 – 1000) mg/kg Phenanthrene (0,010 – 500) mg/kg Anthracene (0,010 – 1000) mg/kg Fluoranthene (0,050 – 500) mg/kg Pyrene (0,010 – 500) mg/kg Benzo(a)anthracene (0,010 – 500) mg/kg Chrysene (0,010 – 500) mg/kg Benzo(b)fluoranthene (0,010 – 500) mg/kg Benzo(k)fluoranthene (0,010 – 500) mg/kg Benzo(a)pyrene (0,0060 – 500) mg/kg Dibenzo(a,h)anthracene (0,010 – 500) mg/kg Benzo(g,h,i)perylene (0,010 – 500) mg/kg Indeno(1,2,3-cd)pyrene (0,010 – 500) mg/kg High performance liquid chromatography with fluorescence detection (HPLC-FLD) and with UV detection (HPLC-UV) method Sum of PAH (calculated) PN-ISO 13877:2004 z wyłączeniem pkt. 7 Instrukcja I-13 wydanie 4 z dnia 17.12.2019 r.","search_zh":"土壤 PN-ISO 13877:2004 z wyłączeniem pkt. 7 Instrukcja I-13 wydanie 4 z dnia 17.12.2019 r.","test_object_zh":"土壤"},{"_id":"6a5a55f49af9f73f382519b2","lab_id":"69ad52a3de79e566650fb664","country":"PL","accr_number":"AB 1249","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 10381-5:2009","norm_bases":["PN-ISO 10381-5:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 10381-5:2009 Gleba Pobieranie probek do badan chemicznych i fizycznych PN-ISO 10381-5:2009","categories":["environment"],"row_index":24,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil Sampling for chemical and physical testing PN-ISO 10381-5:2009","methodology_zh":"化学与物理检测用样品采集","search_zh":"土壤 化学与物理检测用样品采集 PN-ISO 10381-5:2009","test_object_zh":"土壤"},{"_id":"6a5a55f49af9f73f382519b3","lab_id":"69ad52a3de79e566650fb664","country":"PL","accr_number":"AB 1249","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Zawartość anionów Zakres: fluorki (0,5 – 500) mg/kg chlorki (1,0 – 5000) mg/kg bromki (0,25 – 125) mg/kg fosforany (0,4 – 250) mg/kg siarczany (1,0 – 5000) mg/kg azotany (III) (0,1 – 50) mg/kg azotany (V) (0,10 – 125) mg/kg N-NO (0,025 – 15) mg/kg 2 N-NO (0,025 – 28) mg/kg 3 P-PO (0,15 – 82) mg/kg 4 Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","methodology_en":"Anion content Range: fluorides (0,5 – 500) mg/kg chlorides (1,0 – 5000) mg/kg bromides (0,25 – 125) mg/kg phosphates (0,4 – 250) mg/kg sulphates (1,0 – 5000) mg/kg nitrites (III) (0,1 – 50) mg/kg nitrates (V) (0,10 – 125) mg/kg N-NO (0,025 – 15) mg/kg 2 N-NO (0,025 – 28) mg/kg 3 P-PO (0,15 – 82) mg/kg 4 Ion chromatography method with conductometric detection (IC-CD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość anionów Zakres: fluorki (0,5 – 500) mg/kg chlorki (1,0 – 5000) mg/kg bromki (0,25 – 125) mg/kg fosforany (0,4 – 250) mg/kg siarczany (1,0 – 5000) mg/kg azotany (III) (0,1 – 50) mg/kg azotany (V) (0,10 – 125) mg/kg N-NO (0,025 – 15) mg/kg 2 N-NO (0,025 – 28) mg/kg 3 P-PO (0,15 – 82) mg/kg 4 Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"Procedura badawcza PB-3 wydanie 6 z dnia 10.01.2020 r. PN-EN ISO 10304-1:2009","norm_bases":["Procedura badawcza PB-3 wydanie 6 z dnia 10.01.2020 r. PN-EN ISO 10304-1:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Zawartość anionów Zakres: fluorki (0,5 – 500) mg/kg chlorki (1,0 – 5000) mg/kg bromki (0,25 – 125) mg/kg fosforany (0,4 – 250) mg/kg siarczany (1,0 – 5000) mg/kg azotany (III) (0,1 – 50) mg/kg azotany (V) (0,10 – 125) mg/kg N-NO (0,025 – 15) mg/kg 2 N-NO (0,025 – 28) mg/kg 3 P-PO (0,15 – 82) mg/kg 4 Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Procedura badawcza PB-3 wydanie 6 z dnia 10.01.2020 r. PN-EN ISO 10304-1:2009 Gleba Zawartosc anionow Zakres: fluorki (0,5 – 500) mg/kg chlorki (1,0 – 5000) mg/kg bromki (0,25 – 125) mg/kg fosforany (0,4 – 250) mg/kg siarczany (1,0 – 5000) mg/kg azotany (III) (0,1 – 50) mg/kg azotany (V) (0,10 – 125) mg/kg N-NO (0,025 – 15) mg/kg 2 N-NO (0,025 – 28) mg/kg 3 P-PO (0,15 – 82) mg/kg 4 Metoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) Procedura badawcza PB-3 wydanie 6 z dnia 10.01.2020 r. PN-EN ISO 10304-1:2009","categories":["environment"],"row_index":25,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil Anion content Range: fluorides (0,5 – 500) mg/kg chlorides (1,0 – 5000) mg/kg bromides (0,25 – 125) mg/kg phosphates (0,4 – 250) mg/kg sulphates (1,0 – 5000) mg/kg nitrites (III) (0,1 – 50) mg/kg nitrates (V) (0,10 – 125) mg/kg N-NO (0,025 – 15) mg/kg 2 N-NO (0,025 – 28) mg/kg 3 P-PO (0,15 – 82) mg/kg 4 Ion chromatography method with conductometric detection (IC-CD) Procedura badawcza PB-3 wydanie 6 z dnia 10.01.2020 r. PN-EN ISO 10304-1:2009","search_zh":"土壤 Procedura badawcza PB-3 wydanie 6 z dnia 10.01.2020 r. PN-EN ISO 10304-1:2009","test_object_zh":"土壤"},{"_id":"6a5a55f49af9f73f382519b4","lab_id":"69ad52a3de79e566650fb664","country":"PL","accr_number":"AB 1249","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Zawartość kationów Zakres: lit (25 – 500) mg/kg sód (25 – 5000) mg/kg jon amonowy (0,75 – 50) mg/kg potas (25 – 5000) mg/kg magnez (25 – 2500) mg/kg wapń (25 – 5000) mg/kg azot amonowy (0,60 – 39) mg/kg Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","methodology_en":"Cation content Range: lithium (25 – 500) mg/kg sodium (25 – 5000) mg/kg ammonium ion (0,75 – 50) mg/kg potassium (25 – 5000) mg/kg magnesium (25 – 2500) mg/kg calcium (25 – 5000) mg/kg ammonium nitrogen (0,60 – 39) mg/kg Ion chromatography method with conductometric detection (IC-CD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość kationów Zakres: lit (25 – 500) mg/kg sód (25 – 5000) mg/kg jon amonowy (0,75 – 50) mg/kg potas (25 – 5000) mg/kg magnez (25 – 2500) mg/kg wapń (25 – 5000) mg/kg azot amonowy (0,60 – 39) mg/kg Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"Procedura badawcza PB-3 wydanie 6 z dnia 10.01.2020 r. PN-EN ISO 14911:2002","norm_bases":["Procedura badawcza PB-3 wydanie 6 z dnia 10.01.2020 r. PN-EN ISO 14911:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Zawartość kationów Zakres: lit (25 – 500) mg/kg sód (25 – 5000) mg/kg jon amonowy (0,75 – 50) mg/kg potas (25 – 5000) mg/kg magnez (25 – 2500) mg/kg wapń (25 – 5000) mg/kg azot amonowy (0,60 – 39) mg/kg Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Procedura badawcza PB-3 wydanie 6 z dnia 10.01.2020 r. PN-EN ISO 14911:2002 Gleba Zawartosc kationow Zakres: lit (25 – 500) mg/kg sod (25 – 5000) mg/kg jon amonowy (0,75 – 50) mg/kg potas (25 – 5000) mg/kg magnez (25 – 2500) mg/kg wapn (25 – 5000) mg/kg azot amonowy (0,60 – 39) mg/kg Metoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) Procedura badawcza PB-3 wydanie 6 z dnia 10.01.2020 r. PN-EN ISO 14911:2002","categories":["environment"],"row_index":26,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil Cation content Range: lithium (25 – 500) mg/kg sodium (25 – 5000) mg/kg ammonium ion (0,75 – 50) mg/kg potassium (25 – 5000) mg/kg magnesium (25 – 2500) mg/kg calcium (25 – 5000) mg/kg ammonium nitrogen (0,60 – 39) mg/kg Ion chromatography method with conductometric detection (IC-CD) Procedura badawcza PB-3 wydanie 6 z dnia 10.01.2020 r. PN-EN ISO 14911:2002","search_zh":"土壤 Procedura badawcza PB-3 wydanie 6 z dnia 10.01.2020 r. PN-EN ISO 14911:2002","test_object_zh":"土壤"},{"_id":"6a5a55f49af9f73f382519b5","lab_id":"69ad52a3de79e566650fb664","country":"PL","accr_number":"AB 1249","accr_body":"PCA","test_object":"Gleba, nawozy: kompost, osady ściekowe","test_object_en":"Soil, fertilisers: compost, sewage sludge","methodology":"pH - w H O, w KCl, w CaCl 2 2 Zakres: 3,0 – 12,0 Metoda potencjometryczna","methodology_en":"pH - in H O, in KCl, in CaCl 2 2 Range: 3,0 – 12,0 Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH - w H O, w KCl, w CaCl 2 2 Zakres: 3,0 – 12,0 Metoda potencjometryczna","reference":"PN-ISO 10390:2022-09","norm_bases":["PN-ISO 10390:2022-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba, nawozy: kompost, osady ściekowe pH - w H O, w KCl, w CaCl 2 2 Zakres: 3,0 – 12,0 Metoda potencjometryczna PN-ISO 10390:2022-09 Gleba, nawozy: kompost, osady sciekowe pH - w H O, w KCl, w CaCl 2 2 Zakres: 3,0 – 12,0 Metoda potencjometryczna PN-ISO 10390:2022-09","categories":["water","environment"],"row_index":27,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil, fertilisers: compost, sewage sludge pH - in H O, in KCl, in CaCl 2 2 Range: 3,0 – 12,0 Potentiometric method PN-ISO 10390:2022-09"},{"_id":"6a5a55f49af9f73f382519b6","lab_id":"69ad52a3de79e566650fb664","country":"PL","accr_number":"AB 1249","accr_body":"PCA","test_object":"Gleba, nawozy: kompost, osady ściekowe","test_object_en":"Soil, fertilisers: compost, sewage sludge","methodology":"Zawartość pierwiastków Zakres: arsen (3,0 – 5000) mg/kg bar (1,0 – 5000) mg/kg chrom (1,0 – 5000) mg/kg cyna (1,0 – 5000) mg/kg cynk (1,0 – 5000) mg/kg kadm (0,25 – 5000) mg/kg kobalt (1,0 – 5000) mg/kg miedź (1,0 – 5000) mg/kg mangan (1,0 – 5000) mg/kg molibden (1,0 – 5000) mg/kg nikiel (1,0 – 5000) mg/kg ołów (1,0 – 5000) mg/kg rtęć (0,50 – 2500) mg/kg fosfor (5,0 – 5000) mg/kg magnez (1,0 – 5000) mg/kg wapń (125 – 25000) mg/kg potas (125 – 25000) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","methodology_en":"Content of elements Range: arsenic (3,0 – 5000) mg/kg barium (1,0 – 5000) mg/kg chromium (1,0 – 5000) mg/kg tin (1,0 – 5000) mg/kg zinc (1,0 – 5000) mg/kg cadmium (0,25 – 5000) mg/kg cobalt (1,0 – 5000) mg/kg copper (1,0 – 5000) mg/kg manganese (1,0 – 5000) mg/kg molybdenum (1,0 – 5000) mg/kg nickel (1,0 – 5000) mg/kg lead (1,0 – 5000) mg/kg mercury (0,50 – 2500) mg/kg phosphorus (5,0 – 5000) mg/kg magnesium (1,0 – 5000) mg/kg calcium (125 – 25000) mg/kg potassium (125 – 25000) mg/kg Inductively coupled plasma atomic emission spectrometry (ICP-OES) method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość pierwiastków Zakres: arsen (3,0 – 5000) mg/kg bar (1,0 – 5000) mg/kg chrom (1,0 – 5000) mg/kg cyna (1,0 – 5000) mg/kg cynk (1,0 – 5000) mg/kg kadm (0,25 – 5000) mg/kg kobalt (1,0 – 5000) mg/kg miedź (1,0 – 5000) mg/kg mangan (1,0 – 5000) mg/kg molibden (1,0 – 5000) mg/kg nikiel (1,0 – 5000) mg/kg ołów (1,0 – 5000) mg/kg rtęć (0,50 – 2500) mg/kg fosfor (5,0 – 5000) mg/kg magnez (1,0 – 5000) mg/kg wapń (125 – 25000) mg/kg potas (125 – 25000) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN 16170:2017-02","norm_bases":["PN-EN 16170:2017-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba, nawozy: kompost, osady ściekowe Zawartość pierwiastków Zakres: arsen (3,0 – 5000) mg/kg bar (1,0 – 5000) mg/kg chrom (1,0 – 5000) mg/kg cyna (1,0 – 5000) mg/kg cynk (1,0 – 5000) mg/kg kadm (0,25 – 5000) mg/kg kobalt (1,0 – 5000) mg/kg miedź (1,0 – 5000) mg/kg mangan (1,0 – 5000) mg/kg molibden (1,0 – 5000) mg/kg nikiel (1,0 – 5000) mg/kg ołów (1,0 – 5000) mg/kg rtęć (0,50 – 2500) mg/kg fosfor (5,0 – 5000) mg/kg magnez (1,0 – 5000) mg/kg wapń (125 – 25000) mg/kg potas (125 – 25000) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN 16170:2017-02 Gleba, nawozy: kompost, osady sciekowe Zawartosc pierwiastkow Zakres: arsen (3,0 – 5000) mg/kg bar (1,0 – 5000) mg/kg chrom (1,0 – 5000) mg/kg cyna (1,0 – 5000) mg/kg cynk (1,0 – 5000) mg/kg kadm (0,25 – 5000) mg/kg kobalt (1,0 – 5000) mg/kg miedz (1,0 – 5000) mg/kg mangan (1,0 – 5000) mg/kg molibden (1,0 – 5000) mg/kg nikiel (1,0 – 5000) mg/kg olow (1,0 – 5000) mg/kg rtec (0,50 – 2500) mg/kg fosfor (5,0 – 5000) mg/kg magnez (1,0 – 5000) mg/kg wapn (125 – 25000) mg/kg potas (125 – 25000) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN 16170:2017-02","categories":["water","materials","environment"],"row_index":28,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil, fertilisers: compost, sewage sludge Content of elements Range: arsenic (3,0 – 5000) mg/kg barium (1,0 – 5000) mg/kg chromium (1,0 – 5000) mg/kg tin (1,0 – 5000) mg/kg zinc (1,0 – 5000) mg/kg cadmium (0,25 – 5000) mg/kg cobalt (1,0 – 5000) mg/kg copper (1,0 – 5000) mg/kg manganese (1,0 – 5000) mg/kg molybdenum (1,0 – 5000) mg/kg nickel (1,0 – 5000) mg/kg lead (1,0 – 5000) mg/kg mercury (0,50 – 2500) mg/kg phosphorus (5,0 – 5000) mg/kg magnesium (1,0 – 5000) mg/kg calcium (125 – 25000) mg/kg potassium (125 – 25000) mg/kg Inductively coupled plasma atomic emission spectrometry (ICP-OES) method PN-EN 16170:2017-02"}],"has_pdf":true}