🇵🇱 SPÓŁKA KOMUNALNA WSCHOWA Sp. z o.o. PL

PCA AB 1248 • Wschowa, Poland • 27 methods

Water & wastewater

SPÓŁKA KOMUNALNA WSCHOWA Sp. z o.o. is a laboratory accredited by PCA under number AB 1248 (Wschowa, Poland). Its accreditation scope covers 27 test methods in the following areas: Water & wastewater. Test objects include: Wastewater, Water, Water intended for human consumption, Wastewater, Water, Water intended for human consumption, Water intended for human consumption. Most frequently used techniques: Spectrophotometric method, Electrochemical method, Conductometric method.

At a glance

  • Accreditation number: PCA AB 1248
  • Methods in scope: 27
  • Types of test objects: 4
  • Techniques used: 10
  • City: Wschowa, Poland
Accreditation number
AB 1248
Accreditation body
PCA
Address
ul. Daszyńskiego 10, 67-400 Wschowa, LABORATORIUM ZAKŁADOWE, ul. Kazimierza Wielkiego 24, 67-400 Wschowa
City
Wschowa, Poland

What this laboratory tests (4)

Analytical techniques used (10)

Accreditation scope — test methods (27)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Water, Water intended for human consumption Manganese concentration
Range (0,010 – 1,00) mg/l
Spectrophotometric method PN-92/C-04590/03
2 Water, Water intended for human consumption Colour PN-EN ISO 7887:2012 Metoda D | PN-EN ISO 7887:2012
3 Water, Water intended for human consumption
Range (5 – 50) mg/l Pt
Visual method Metoda D
4 Water, Water intended for human consumption Electrical conductivity
Range (147 – 1417) μS/cm
Conductometric method PN-EN 27888:1999
5 Water, Water intended for human consumption Turbidity
Range (0,2 – 15) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
6 Water, Water intended for human consumption, Wastewater Ammonium nitrogen concentration
Range (0,080 – 130) mg/l
Spectrophotometric method PB-05 wyd.05 z dnia 27.01.2025 r. | na podstawie testu Hach Lange nr LCK 302, 303, 304
7 Water, Water intended for human consumption, Wastewater Total iron concentration
Range (0,020 – 3,50) mg/l
Spectrophotometric method PN-ISO 6332:2001 + Ap1:2016-06
8 Water, Water intended for human consumption, Wastewater Ammonium nitrogen concentration
Range (0,080 – 130) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
9 Water, Water intended for human consumption, Wastewater Sulfate concentration
Range (5,0 – 250) mg/l
Spectrophotometric method P B - 0 3 w y d.04 z dnia 27.01.2025 r. | na podstawie testu Merck nr 14548
10 Water, Water intended for human consumption, Wastewater Nitrate nitrogen concentration
Range (0,050 – 40) mg/l
Spectrophotometric method PN-82/C-04576/08
11 Water, Water intended for human consumption, Wastewater Nitrite nitrogen concentration
Range 0,004 – 0,60 mg/l
Spectrophotometric method PN-EN 26777:1999
12 Water, Water intended for human consumption, Wastewater Chloride concentration
Range (5,0 – 500) mg/l
Titrimetric method P N - I S O 9 297:1994
13 Water, Water intended for human consumption, Wastewater pH
Range (4,0 – 10,0)
Potentiometric method PN-EN ISO 10523:2012
14 Wastewater Chemical oxygen demand PN-ISO 15705:2005
15 Wastewater COD-Cr
Range (15,0 – 10000) mg/l
Spectrophotometric method PN-ISO 15705:2005
16 Wastewater Biochemical oxygen demand - PN-EN ISO 5815-1:2019-12
17 Wastewater BOD5
Range (1 – 6000) mg/l O2
Electrochemical method PN-EN ISO 5815-1:2019-12
18 Wastewater Biochemical oxygen demand - PN-EN 1899-2:2002
19 Wastewater BOD5
Range (0,5 – 6,0) mg/l O2
Electrochemical method PN-EN 1899-2:2002
20 Wastewater Oxygen concentration
Range (0,5 – 15) mg/l O2
Electrochemical method PN-EN ISO 5814:2013-04
21 Wastewater Biochemical oxygen demand - PB-02 wyd. 04 z dnia 27.01.2025 r. | na podstawie metody Oxitop - control
22 Wastewater BOD5
Range (4,0 – 4000) mg/l O2
Manometric method PB-02 wyd. 04 z dnia 27.01.2025 r. | na podstawie metody Oxitop - control
23 Wastewater Total phosphorus concentration
Range (0,50 – 40) mg/l
Spectrophotometric method PB-04 wyd.07 z dnia 27.01.2025 r. | na podstawie testu Hach Lange nr LCK 348, 350
24 Wastewater Total suspended solids (TSS)
Range (2,0 – 1000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
25 Wastewater Total nitrogen concentration
Range (5,0 – 200) mg/l
Spectrophotometric method PB-08 wyd. 05 z dnia 27.01.2025 r. | na podstawie testu Hach Lange nr LCK 238, 338
26 Water intended for human consumption Sampling for chemical and physical testing Temperature
Range (5,0 – 25,0)°C
PN ISO 5667-5:2017-10 | PB-11 wyd. 04 z dnia 27.01.2025 r
27 Wastewater Sampling for chemical and physical testing
Temperature Range (5,0 – 25,0)°C
Manual method PN-ISO 5667-10:2021-11 | PB-11 wyd. 04 z dnia 27.01.2025 r.

Reference standards (31)

Metoda D
P B - 0 3 w y d.04 z dnia 27.01.2025 r.
P N - I S O 9 297:1994
PB-02 wyd. 04 z dnia 27.01.2025 r.
PB-04 wyd.07 z dnia 27.01.2025 r.
PB-05 wyd.05 z dnia 27.01.2025 r.
PB-08 wyd. 05 z dnia 27.01.2025 r.
PB-11 wyd. 04 z dnia 27.01.2025 r
PB-11 wyd. 04 z dnia 27.01.2025 r.
PN ISO 5667-5:2017-10
PN-82/C-04576/08
PN-92/C-04590/03
PN-EN 1899-2:2002
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 5814:2013-04
PN-EN ISO 5815-1:2019-12
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012
PN-EN ISO 7887:2012 Metoda D
PN-ISO 15705:2005
PN-ISO 5667-10:2021-11
PN-ISO 6332:2001 + Ap1:2016-06
PN-ISO 7150-1:2002
na podstawie metody Oxitop - control
na podstawie testu Hach Lange nr LCK 238, 338
na podstawie testu Hach Lange nr LCK 302, 303, 304
na podstawie testu Hach Lange nr LCK 348, 350
na podstawie testu Merck nr 14548