🇵🇱 SPÓŁKA KOMUNALNA WSCHOWA Sp. z o.o. PL
Water & wastewater
SPÓŁKA KOMUNALNA WSCHOWA Sp. z o.o. is a laboratory accredited by PCA under number AB 1248 (Wschowa, Poland). Its accreditation scope covers 27 test methods in the following areas: Water & wastewater. Test objects include: Wastewater, Water, Water intended for human consumption, Wastewater, Water, Water intended for human consumption, Water intended for human consumption. Most frequently used techniques: Spectrophotometric method, Electrochemical method, Conductometric method.
At a glance
- Accreditation number: PCA AB 1248
- Methods in scope: 27
- Types of test objects: 4
- Techniques used: 10
- City: Wschowa, Poland
- Accreditation number
- AB 1248
- Accreditation body
- PCA
- Address
- ul. Daszyńskiego 10, 67-400 Wschowa, LABORATORIUM ZAKŁADOWE, ul. Kazimierza Wielkiego 24, 67-400 Wschowa
- City
- Wschowa, Poland
What this laboratory tests (4)
- Wastewater — 13 methods
- Water, Water intended for human consumption, Wastewater — 8 methods
- Water, Water intended for human consumption — 5 methods
- Water intended for human consumption — 1 method
Analytical techniques used (10)
- Spectrophotometric method — 10 methods
- Electrochemical method — 3 methods
- Conductometric method — 1 method
- Gravimetric method — 1 method
- Manometric method — 1 method
- Manual method — 1 method
- Nephelometric method — 1 method
- Potentiometric method — 1 method
- Titrimetric method — 1 method
- Visual method — 1 method
Accreditation scope — test methods (27)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Water, Water intended for human consumption | Manganese concentration Range (0,010 – 1,00) mg/l |
Spectrophotometric method | PN-92/C-04590/03 | |
| 2 | Water, Water intended for human consumption | Colour | PN-EN ISO 7887:2012 Metoda D | PN-EN ISO 7887:2012 | ||
| 3 | Water, Water intended for human consumption | Range (5 – 50) mg/l Pt |
Visual method | Metoda D | |
| 4 | Water, Water intended for human consumption | Electrical conductivity Range (147 – 1417) μS/cm |
Conductometric method | PN-EN 27888:1999 | |
| 5 | Water, Water intended for human consumption | Turbidity Range (0,2 – 15) NTU |
Nephelometric method | PN-EN ISO 7027-1:2016-09 | |
| 6 | Water, Water intended for human consumption, Wastewater | Ammonium nitrogen concentration Range (0,080 – 130) mg/l |
Spectrophotometric method | PB-05 wyd.05 z dnia 27.01.2025 r. | na podstawie testu Hach Lange nr LCK 302, 303, 304 | |
| 7 | Water, Water intended for human consumption, Wastewater | Total iron concentration Range (0,020 – 3,50) mg/l |
Spectrophotometric method | PN-ISO 6332:2001 + Ap1:2016-06 | |
| 8 | Water, Water intended for human consumption, Wastewater | Ammonium nitrogen concentration Range (0,080 – 130) mg/l |
Spectrophotometric method | PN-ISO 7150-1:2002 | |
| 9 | Water, Water intended for human consumption, Wastewater | Sulfate concentration Range (5,0 – 250) mg/l |
Spectrophotometric method | P B - 0 3 w y d.04 z dnia 27.01.2025 r. | na podstawie testu Merck nr 14548 | |
| 10 | Water, Water intended for human consumption, Wastewater | Nitrate nitrogen concentration Range (0,050 – 40) mg/l |
Spectrophotometric method | PN-82/C-04576/08 | |
| 11 | Water, Water intended for human consumption, Wastewater | Nitrite nitrogen concentration Range 0,004 – 0,60 mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 12 | Water, Water intended for human consumption, Wastewater | Chloride concentration Range (5,0 – 500) mg/l |
Titrimetric method | P N - I S O 9 297:1994 | |
| 13 | Water, Water intended for human consumption, Wastewater | pH Range (4,0 – 10,0) |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 14 | Wastewater | Chemical oxygen demand | PN-ISO 15705:2005 | ||
| 15 | Wastewater | COD-Cr Range (15,0 – 10000) mg/l |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 16 | Wastewater | Biochemical oxygen demand - | PN-EN ISO 5815-1:2019-12 | ||
| 17 | Wastewater | BOD5 Range (1 – 6000) mg/l O2 |
Electrochemical method | PN-EN ISO 5815-1:2019-12 | |
| 18 | Wastewater | Biochemical oxygen demand - | PN-EN 1899-2:2002 | ||
| 19 | Wastewater | BOD5 Range (0,5 – 6,0) mg/l O2 |
Electrochemical method | PN-EN 1899-2:2002 | |
| 20 | Wastewater | Oxygen concentration Range (0,5 – 15) mg/l O2 |
Electrochemical method | PN-EN ISO 5814:2013-04 | |
| 21 | Wastewater | Biochemical oxygen demand - | PB-02 wyd. 04 z dnia 27.01.2025 r. | na podstawie metody Oxitop - control | ||
| 22 | Wastewater | BOD5 Range (4,0 – 4000) mg/l O2 |
Manometric method | PB-02 wyd. 04 z dnia 27.01.2025 r. | na podstawie metody Oxitop - control | |
| 23 | Wastewater | Total phosphorus concentration Range (0,50 – 40) mg/l |
Spectrophotometric method | PB-04 wyd.07 z dnia 27.01.2025 r. | na podstawie testu Hach Lange nr LCK 348, 350 | |
| 24 | Wastewater | Total suspended solids (TSS) Range (2,0 – 1000) mg/l |
Gravimetric method | PN-EN 872:2007+Ap1:2007 | |
| 25 | Wastewater | Total nitrogen concentration Range (5,0 – 200) mg/l |
Spectrophotometric method | PB-08 wyd. 05 z dnia 27.01.2025 r. | na podstawie testu Hach Lange nr LCK 238, 338 | |
| 26 | Water intended for human consumption | Sampling for chemical and physical testing Temperature Range (5,0 – 25,0)°C |
PN ISO 5667-5:2017-10 | PB-11 wyd. 04 z dnia 27.01.2025 r | ||
| 27 | Wastewater | Sampling for chemical and physical testing Temperature Range (5,0 – 25,0)°C |
Manual method | PN-ISO 5667-10:2021-11 | PB-11 wyd. 04 z dnia 27.01.2025 r. | |
Reference standards (31)
Metoda D
P B - 0 3 w y d.04 z dnia 27.01.2025 r.
P N - I S O 9 297:1994
PB-02 wyd. 04 z dnia 27.01.2025 r.
PB-04 wyd.07 z dnia 27.01.2025 r.
PB-05 wyd.05 z dnia 27.01.2025 r.
PB-08 wyd. 05 z dnia 27.01.2025 r.
PB-11 wyd. 04 z dnia 27.01.2025 r
PB-11 wyd. 04 z dnia 27.01.2025 r.
PN ISO 5667-5:2017-10
PN-82/C-04576/08
PN-92/C-04590/03
PN-EN 1899-2:2002
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 5814:2013-04
PN-EN ISO 5815-1:2019-12
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012
PN-EN ISO 7887:2012 Metoda D
PN-ISO 15705:2005
PN-ISO 5667-10:2021-11
PN-ISO 6332:2001 + Ap1:2016-06
PN-ISO 7150-1:2002
na podstawie metody Oxitop - control
na podstawie testu Hach Lange nr LCK 238, 338
na podstawie testu Hach Lange nr LCK 302, 303, 304
na podstawie testu Hach Lange nr LCK 348, 350
na podstawie testu Merck nr 14548