{"lab":{"_id":"69ad52a3de79e566650fb662","accr_number":"AB 1248","country":"PL","accr_body":"PCA","address":"ul. Daszyńskiego 10, 67-400 Wschowa, LABORATORIUM ZAKŁADOWE, ul. Kazimierza Wielkiego 24, 67-400 Wschowa","categories":["water"],"city":"Wschowa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":27,"name":"SPÓŁKA KOMUNALNA WSCHOWA Sp. z o.o.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1248.pdf"],"scope_summary":"","search_text":"spółka komunalna wschowa sp. z o.o. ul. daszyńskiego 10, 67-400 wschowa, laboratorium zakładowe, ul. kazimierza wielkiego 24, 67-400 wschowa water other pharma electronics metrology","status":"active","updated_at":"2026-03-08T14:50:25.321Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:25.321Z","email_confidence":"high","email_mx":true,"email_source":"https://skwschowa.pl/kontakt/","parse_date":"2026-07-20T19:34:22.130Z","parse_source":"script-pdfplumber","fields_of_testing":[{"codes":"C/30/P; C/29/P","pl":"Badania chemiczne i pobieranie próbek ścieków i wody do spożycia przez ludzi","en":"Chemical tests and sampling of sewage and drinking water"},{"codes":"C/28","pl":"Badania chemiczne wody","en":"Chemical tests of water"},{"codes":"N/30/P; N/29/P","pl":"Badania właściwości fizycznych i pobieranie próbek ścieków i wody do spożycia przez ludzi","en":"Tests of physical properties and sampling of sewage and drinking water"},{"codes":"N/28","pl":"Badania właściwości fizycznych wody","en":"Tests of physical properties of water"}],"issue":{"no":"14","date":"06.02.2026"},"map_coord":[51.807947,16.320967],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":27,"metrology":1},"category_scores":{"water":26.04,"metrology":0.04},"has_zh":true},"methods":[{"_id":"6a5e783e4cc76d93cba39abd","lab_id":"69ad52a3de79e566650fb662","country":"PL","accr_number":"AB 1248","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie manganu","methodology_en":"Manganese concentration","parameters":[{"name":"Zakres","range":"(0,010 – 1,00) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,010 – 1,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie manganu\nZakres (0,010 – 1,00) mg/l\nMetoda spektrofotometryczna","reference":"PN-92/C-04590/03","norm_bases":["PN-92/C-04590/03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie manganu\nZakres (0,010 – 1,00) mg/l\nMetoda spektrofotometryczna PN-92/C-04590/03 Woda, Woda do spozycia przez ludzi Stezenie manganu\nZakres (0,010 – 1,00) mg/l\nMetoda spektrofotometryczna PN-92/C-04590/03","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Manganese concentration Spectrophotometric method Range PN-92/C-04590/03","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 1,00) mg/l"}],"search_zh":"水、生活饮用水 锰浓度 分光光度法 范围 PN-92/C-04590/03","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5e783e4cc76d93cba39abe","lab_id":"69ad52a3de79e566650fb662","country":"PL","accr_number":"AB 1248","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Barwa","methodology_en":"Colour","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Barwa","reference":"PN-EN ISO 7887:2012 Metoda D | PN-EN ISO 7887:2012","norm_bases":["PN-EN ISO 7887:2012 Metoda D","PN-EN ISO 7887:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Barwa PN-EN ISO 7887:2012 Metoda D | PN-EN ISO 7887:2012 Woda, Woda do spozycia przez ludzi Barwa PN-EN ISO 7887:2012 Metoda D | PN-EN ISO 7887:2012","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Colour PN-EN ISO 7887:2012 Metoda D | PN-EN ISO 7887:2012","methodology_zh":"色度","search_zh":"水、生活饮用水 色度 PN-EN ISO 7887:2012 Metoda D | PN-EN ISO 7887:2012","test_object_zh":"水、生活饮用水"},{"_id":"6a5e783e4cc76d93cba39abf","lab_id":"69ad52a3de79e566650fb662","country":"PL","accr_number":"AB 1248","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"","methodology_en":null,"parameters":[{"name":"Zakres","range":"(5 – 50) mg/l Pt"}],"parameters_en":[{"name":"Range","range":"(5 – 50) mg/l Pt"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"technique_en":"Visual method","computed":[],"computed_en":[],"activity":"\nZakres (5 – 50) mg/l Pt\nMetoda wizualna","reference":"Metoda D","norm_bases":["Metoda D"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi \nZakres (5 – 50) mg/l Pt\nMetoda wizualna Metoda D Woda, Woda do spozycia przez ludzi \nZakres (5 – 50) mg/l Pt\nMetoda wizualna Metoda D","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Visual method Range Metoda D","parameters_zh":[{"name":"范围","range":"(5 – 50) mg/l Pt"}],"search_zh":"水、生活饮用水 目视法 范围 Metoda D","technique_zh":"目视法","test_object_zh":"水、生活饮用水"},{"_id":"6a5e783e4cc76d93cba39ac0","lab_id":"69ad52a3de79e566650fb662","country":"PL","accr_number":"AB 1248","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Przewodność elektryczna właściwa","methodology_en":"Electrical conductivity","parameters":[{"name":"Zakres","range":"(147 – 1417) μS/cm"}],"parameters_en":[{"name":"Range","range":"(147 – 1417) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"technique_en":"Conductometric method","computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa\nZakres (147 – 1417) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres (147 – 1417) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, Woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres (147 – 1417) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Electrical conductivity Conductometric method Range PN-EN 27888:1999","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(147 – 1417) μS/cm"}],"search_zh":"水、生活饮用水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、生活饮用水"},{"_id":"6a5e783e4cc76d93cba39ac1","lab_id":"69ad52a3de79e566650fb662","country":"PL","accr_number":"AB 1248","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Mętność","methodology_en":"Turbidity","parameters":[{"name":"Zakres","range":"(0,2 – 15) NTU"}],"parameters_en":[{"name":"Range","range":"(0,2 – 15) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"technique_en":"Nephelometric method","computed":[],"computed_en":[],"activity":"Mętność\nZakres (0,2 – 15) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Mętność\nZakres (0,2 – 15) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda, Woda do spozycia przez ludzi Metnosc\nZakres (0,2 – 15) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,2 – 15) NTU"}],"search_zh":"水、生活饮用水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水、生活饮用水"},{"_id":"6a5e783e4cc76d93cba39ac2","lab_id":"69ad52a3de79e566650fb662","country":"PL","accr_number":"AB 1248","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology":"Stężenie azotu amonowego","methodology_en":"Ammonium nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,080 – 130) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,080 – 130) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego\nZakres (0,080 – 130) mg/l\nMetoda spektrofotometryczna","reference":"PB-05 wyd.05 z dnia 27.01.2025 r. | na podstawie testu Hach Lange nr LCK 302, 303, 304","norm_bases":["PB-05 wyd.05 z dnia 27.01.2025 r.","na podstawie testu Hach Lange nr LCK 302, 303, 304"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie azotu amonowego\nZakres (0,080 – 130) mg/l\nMetoda spektrofotometryczna PB-05 wyd.05 z dnia 27.01.2025 r. | na podstawie testu Hach Lange nr LCK 302, 303, 304 Woda, Woda do spozycia przez ludzi, Scieki Stezenie azotu amonowego\nZakres (0,080 – 130) mg/l\nMetoda spektrofotometryczna PB-05 wyd.05 z dnia 27.01.2025 r. | na podstawie testu Hach Lange nr LCK 302, 303, 304","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption, Wastewater Ammonium nitrogen concentration Spectrophotometric method Range PB-05 wyd.05 z dnia 27.01.2025 r. | na podstawie testu Hach Lange nr LCK 302, 303, 304","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,080 – 130) mg/l"}],"search_zh":"水、生活饮用水、废水 氨氮浓度 分光光度法 范围 PB-05 wyd.05 z dnia 27.01.2025 r. | na podstawie testu Hach Lange nr LCK 302, 303, 304","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a5e783e4cc76d93cba39ac3","lab_id":"69ad52a3de79e566650fb662","country":"PL","accr_number":"AB 1248","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology":"Stężenie żelaza ogólnego","methodology_en":"Total iron concentration","parameters":[{"name":"Zakres","range":"(0,020 – 3,50) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,020 – 3,50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie żelaza ogólnego\nZakres (0,020 – 3,50) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001 + Ap1:2016-06","norm_bases":["PN-ISO 6332:2001 + Ap1:2016-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie żelaza ogólnego\nZakres (0,020 – 3,50) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 + Ap1:2016-06 Woda, Woda do spozycia przez ludzi, Scieki Stezenie zelaza ogolnego\nZakres (0,020 – 3,50) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 + Ap1:2016-06","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption, Wastewater Total iron concentration Spectrophotometric method Range PN-ISO 6332:2001 + Ap1:2016-06","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(0,020 – 3,50) mg/l"}],"search_zh":"水、生活饮用水、废水 总铁浓度 分光光度法 范围 PN-ISO 6332:2001 + Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a5e783e4cc76d93cba39ac4","lab_id":"69ad52a3de79e566650fb662","country":"PL","accr_number":"AB 1248","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology":"Stężenie azotu amonowego","methodology_en":"Ammonium nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,080 – 130) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,080 – 130) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego\nZakres (0,080 – 130) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie azotu amonowego\nZakres (0,080 – 130) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, Woda do spozycia przez ludzi, Scieki Stezenie azotu amonowego\nZakres (0,080 – 130) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption, Wastewater Ammonium nitrogen concentration Spectrophotometric method Range PN-ISO 7150-1:2002","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,080 – 130) mg/l"}],"search_zh":"水、生活饮用水、废水 氨氮浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a5e783e4cc76d93cba39ac5","lab_id":"69ad52a3de79e566650fb662","country":"PL","accr_number":"AB 1248","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology":"Stężenie siarczanów","methodology_en":"Sulfate concentration","parameters":[{"name":"Zakres","range":"(5,0 – 250) mg/l"}],"parameters_en":[{"name":"Range","range":"(5,0 – 250) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie siarczanów\nZakres (5,0 – 250) mg/l\nMetoda spektrofotometryczna","reference":"P B - 0 3 w y d.04 z dnia 27.01.2025 r. | na podstawie testu Merck nr 14548","norm_bases":["P B - 0 3 w y d.04 z dnia 27.01.2025 r.","na podstawie testu Merck nr 14548"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie siarczanów\nZakres (5,0 – 250) mg/l\nMetoda spektrofotometryczna P B - 0 3 w y d.04 z dnia 27.01.2025 r. | na podstawie testu Merck nr 14548 Woda, Woda do spozycia przez ludzi, Scieki Stezenie siarczanow\nZakres (5,0 – 250) mg/l\nMetoda spektrofotometryczna P B - 0 3 w y d.04 z dnia 27.01.2025 r. | na podstawie testu Merck nr 14548","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption, Wastewater Sulfate concentration Spectrophotometric method Range P B - 0 3 w y d.04 z dnia 27.01.2025 r. | na podstawie testu Merck nr 14548","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 250) mg/l"}],"search_zh":"水、生活饮用水、废水 硫酸盐浓度 分光光度法 范围 P B - 0 3 w y d.04 z dnia 27.01.2025 r. | na podstawie testu Merck nr 14548","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a5e783e4cc76d93cba39ac6","lab_id":"69ad52a3de79e566650fb662","country":"PL","accr_number":"AB 1248","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology":"Stężenie azotu azotanowego","methodology_en":"Nitrate nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,050 – 40) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,050 – 40) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotanowego\nZakres (0,050 – 40) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie azotu azotanowego\nZakres (0,050 – 40) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08 Woda, Woda do spozycia przez ludzi, Scieki Stezenie azotu azotanowego\nZakres (0,050 – 40) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption, Wastewater Nitrate nitrogen concentration Spectrophotometric method Range PN-82/C-04576/08","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,050 – 40) mg/l"}],"search_zh":"水、生活饮用水、废水 硝态氮浓度 分光光度法 范围 PN-82/C-04576/08","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a5e783e4cc76d93cba39ac7","lab_id":"69ad52a3de79e566650fb662","country":"PL","accr_number":"AB 1248","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology":"Stężenie azotu azotynowego","methodology_en":"Nitrite nitrogen concentration","parameters":[{"name":"Zakres","range":"0,004 – 0,60 mg/l"}],"parameters_en":[{"name":"Range","range":"0,004 – 0,60 mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego\nZakres 0,004 – 0,60 mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie azotu azotynowego\nZakres 0,004 – 0,60 mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, Woda do spozycia przez ludzi, Scieki Stezenie azotu azotynowego\nZakres 0,004 – 0,60 mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption, Wastewater Nitrite nitrogen concentration Spectrophotometric method Range PN-EN 26777:1999","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"0,004 – 0,60 mg/l"}],"search_zh":"水、生活饮用水、废水 亚硝态氮浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a5e783e4cc76d93cba39ac8","lab_id":"69ad52a3de79e566650fb662","country":"PL","accr_number":"AB 1248","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(5,0 – 500) mg/l"}],"parameters_en":[{"name":"Range","range":"(5,0 – 500) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (5,0 – 500) mg/l\nMetoda miareczkowa","reference":"P N - I S O 9 297:1994","norm_bases":["P N - I S O 9 297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie chlorków\nZakres (5,0 – 500) mg/l\nMetoda miareczkowa P N - I S O 9 297:1994 Woda, Woda do spozycia przez ludzi, Scieki Stezenie chlorkow\nZakres (5,0 – 500) mg/l\nMetoda miareczkowa P N - I S O 9 297:1994","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption, Wastewater Chloride concentration Titrimetric method Range P N - I S O 9 297:1994","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 500) mg/l"}],"search_zh":"水、生活饮用水、废水 氯化物浓度 滴定法 范围 P N - I S O 9 297:1994","technique_zh":"滴定法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a5e783e4cc76d93cba39ac9","lab_id":"69ad52a3de79e566650fb662","country":"PL","accr_number":"AB 1248","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"(4,0 – 10,0)"}],"parameters_en":[{"name":"Range","range":"(4,0 – 10,0)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres (4,0 – 10,0)\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki pH\nZakres (4,0 – 10,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, Woda do spozycia przez ludzi, Scieki pH\nZakres (4,0 – 10,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption, Wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"(4,0 – 10,0)"}],"search_zh":"水、生活饮用水、废水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a5e783e4cc76d93cba39aca","lab_id":"69ad52a3de79e566650fb662","country":"PL","accr_number":"AB 1248","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Chemiczne zapotrzebowanie tlenu","methodology_en":"Chemical oxygen demand","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu PN-ISO 15705:2005 Scieki Chemiczne zapotrzebowanie tlenu PN-ISO 15705:2005","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Chemical oxygen demand PN-ISO 15705:2005","search_zh":"污水 化学需氧量（COD） PN-ISO 15705:2005","test_object_zh":"污水","methodology_zh":"化学需氧量（COD）"},{"_id":"6a5e783e4cc76d93cba39acb","lab_id":"69ad52a3de79e566650fb662","country":"PL","accr_number":"AB 1248","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"ChZT-Cr","methodology_en":"COD-Cr","parameters":[{"name":"Zakres","range":"(15,0 – 10000) mg/l"}],"parameters_en":[{"name":"Range","range":"(15,0 – 10000) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"ChZT-Cr\nZakres (15,0 – 10000) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki ChZT-Cr\nZakres (15,0 – 10000) mg/l\nMetoda spektrofotometryczna PN-ISO 15705:2005 Scieki ChZT-Cr\nZakres (15,0 – 10000) mg/l\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater COD-Cr Spectrophotometric method Range PN-ISO 15705:2005","parameters_zh":[{"name":"范围","range":"(15,0 – 10000) mg/l"}],"search_zh":"污水 化学需氧量（COD-Cr） 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"化学需氧量（COD-Cr）"},{"_id":"6a5e783e4cc76d93cba39acc","lab_id":"69ad52a3de79e566650fb662","country":"PL","accr_number":"AB 1248","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu -","methodology_en":"Biochemical oxygen demand -","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu -","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu - PN-EN ISO 5815-1:2019-12 Scieki Biochemiczne zapotrzebowanie tlenu - PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Biochemical oxygen demand - PN-EN ISO 5815-1:2019-12","search_zh":"污水 生化需氧量 － PN-EN ISO 5815-1:2019-12","test_object_zh":"污水","methodology_zh":"生化需氧量 －"},{"_id":"6a5e783e4cc76d93cba39acd","lab_id":"69ad52a3de79e566650fb662","country":"PL","accr_number":"AB 1248","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"BZT5","methodology_en":"BOD5","parameters":[{"name":"Zakres","range":"(1 – 6000) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(1 – 6000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"BZT5\nZakres (1 – 6000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki BZT5\nZakres (1 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Scieki BZT5\nZakres (1 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater BOD5 Electrochemical method Range PN-EN ISO 5815-1:2019-12","methodology_zh":"BZT5（BOD5）","parameters_zh":[{"name":"范围","range":"(1 – 6000) mg/l O2"}],"search_zh":"污水 BZT5（BOD5） 电化学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"污水"},{"_id":"6a5e783e4cc76d93cba39ace","lab_id":"69ad52a3de79e566650fb662","country":"PL","accr_number":"AB 1248","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu -","methodology_en":"Biochemical oxygen demand -","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu -","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu - PN-EN 1899-2:2002 Scieki Biochemiczne zapotrzebowanie tlenu - PN-EN 1899-2:2002","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Biochemical oxygen demand - PN-EN 1899-2:2002","search_zh":"污水 生化需氧量 － PN-EN 1899-2:2002","test_object_zh":"污水","methodology_zh":"生化需氧量 －"},{"_id":"6a5e783e4cc76d93cba39acf","lab_id":"69ad52a3de79e566650fb662","country":"PL","accr_number":"AB 1248","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"BZT5","methodology_en":"BOD5","parameters":[{"name":"Zakres","range":"(0,5 – 6,0) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(0,5 – 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Scieki BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater BOD5 Electrochemical method Range PN-EN 1899-2:2002","methodology_zh":"BZT5（BOD5）","parameters_zh":[{"name":"范围","range":"(0,5 – 6,0) mg/l O2"}],"search_zh":"污水 BZT5（BOD5） 电化学法 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"污水"},{"_id":"6a5e783e4cc76d93cba39ad0","lab_id":"69ad52a3de79e566650fb662","country":"PL","accr_number":"AB 1248","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie tlenu","methodology_en":"Oxygen concentration","parameters":[{"name":"Zakres","range":"(0,5 – 15) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(0,5 – 15) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Stężenie tlenu\nZakres (0,5 – 15) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5814:2013-04","norm_bases":["PN-EN ISO 5814:2013-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie tlenu\nZakres (0,5 – 15) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5814:2013-04 Scieki Stezenie tlenu\nZakres (0,5 – 15) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5814:2013-04","categories":["water"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Oxygen concentration Electrochemical method Range PN-EN ISO 5814:2013-04","parameters_zh":[{"name":"范围","range":"(0,5 – 15) mg/l O2"}],"search_zh":"污水 氧浓度 电化学法 范围 PN-EN ISO 5814:2013-04","technique_zh":"电化学法","test_object_zh":"污水","methodology_zh":"氧浓度"},{"_id":"6a5e783e4cc76d93cba39ad1","lab_id":"69ad52a3de79e566650fb662","country":"PL","accr_number":"AB 1248","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu -","methodology_en":"Biochemical oxygen demand -","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu -","reference":"PB-02 wyd. 04 z dnia 27.01.2025 r. | na podstawie metody Oxitop - control","norm_bases":["PB-02 wyd. 04 z dnia 27.01.2025 r.","na podstawie metody Oxitop - control"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu - PB-02 wyd. 04 z dnia 27.01.2025 r. | na podstawie metody Oxitop - control Scieki Biochemiczne zapotrzebowanie tlenu - PB-02 wyd. 04 z dnia 27.01.2025 r. | na podstawie metody Oxitop - control","categories":["water"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Biochemical oxygen demand - PB-02 wyd. 04 z dnia 27.01.2025 r. | na podstawie metody Oxitop - control","search_zh":"污水 生化需氧量 － PB-02 wyd. 04 z dnia 27.01.2025 r. | na podstawie metody Oxitop - control","test_object_zh":"污水","methodology_zh":"生化需氧量 －"},{"_id":"6a5e783e4cc76d93cba39ad2","lab_id":"69ad52a3de79e566650fb662","country":"PL","accr_number":"AB 1248","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"BZT5","methodology_en":"BOD5","parameters":[{"name":"Zakres","range":"(4,0 – 4000) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(4,0 – 4000) mg/l O2"}],"technique":"Metoda manometryczna","techniques":["Metoda manometryczna"],"technique_en":"Manometric method","computed":[],"computed_en":[],"activity":"BZT5\nZakres (4,0 – 4000) mg/l O2\nMetoda manometryczna","reference":"PB-02 wyd. 04 z dnia 27.01.2025 r. | na podstawie metody Oxitop - control","norm_bases":["PB-02 wyd. 04 z dnia 27.01.2025 r.","na podstawie metody Oxitop - control"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki BZT5\nZakres (4,0 – 4000) mg/l O2\nMetoda manometryczna PB-02 wyd. 04 z dnia 27.01.2025 r. | na podstawie metody Oxitop - control Scieki BZT5\nZakres (4,0 – 4000) mg/l O2\nMetoda manometryczna PB-02 wyd. 04 z dnia 27.01.2025 r. | na podstawie metody Oxitop - control","categories":["water","metrology"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater BOD5 Manometric method Range PB-02 wyd. 04 z dnia 27.01.2025 r. | na podstawie metody Oxitop - control","methodology_zh":"BZT5（BOD5）","parameters_zh":[{"name":"范围","range":"(4,0 – 4000) mg/l O2"}],"search_zh":"污水 BZT5（BOD5） 压力计法 范围 PB-02 wyd. 04 z dnia 27.01.2025 r. | na podstawie metody Oxitop - control","test_object_zh":"污水","technique_zh":"压力计法"},{"_id":"6a5e783e4cc76d93cba39ad3","lab_id":"69ad52a3de79e566650fb662","country":"PL","accr_number":"AB 1248","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie fosforu ogólnego","methodology_en":"Total phosphorus concentration","parameters":[{"name":"Zakres","range":"(0,50 – 40) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,50 – 40) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,50 – 40) mg/l\nMetoda spektrofotometryczna","reference":"PB-04 wyd.07 z dnia 27.01.2025 r. | na podstawie testu Hach Lange nr LCK 348, 350","norm_bases":["PB-04 wyd.07 z dnia 27.01.2025 r.","na podstawie testu Hach Lange nr LCK 348, 350"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie fosforu ogólnego\nZakres (0,50 – 40) mg/l\nMetoda spektrofotometryczna PB-04 wyd.07 z dnia 27.01.2025 r. | na podstawie testu Hach Lange nr LCK 348, 350 Scieki Stezenie fosforu ogolnego\nZakres (0,50 – 40) mg/l\nMetoda spektrofotometryczna PB-04 wyd.07 z dnia 27.01.2025 r. | na podstawie testu Hach Lange nr LCK 348, 350","categories":["water"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Total phosphorus concentration Spectrophotometric method Range PB-04 wyd.07 z dnia 27.01.2025 r. | na podstawie testu Hach Lange nr LCK 348, 350","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,50 – 40) mg/l"}],"search_zh":"污水 总磷浓度 分光光度法 范围 PB-04 wyd.07 z dnia 27.01.2025 r. | na podstawie testu Hach Lange nr LCK 348, 350","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a5e783e4cc76d93cba39ad4","lab_id":"69ad52a3de79e566650fb662","country":"PL","accr_number":"AB 1248","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(2,0 – 1000) mg/l"}],"parameters_en":[{"name":"Range","range":"(2,0 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Zawiesiny ogólne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Scieki Zawiesiny ogolne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 1000) mg/l"}],"search_zh":"污水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"污水"},{"_id":"6a5e783e4cc76d93cba39ad5","lab_id":"69ad52a3de79e566650fb662","country":"PL","accr_number":"AB 1248","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu ogólnego","methodology_en":"Total nitrogen concentration","parameters":[{"name":"Zakres","range":"(5,0 – 200) mg/l"}],"parameters_en":[{"name":"Range","range":"(5,0 – 200) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego\nZakres (5,0 – 200) mg/l\nMetoda spektrofotometryczna","reference":"PB-08 wyd. 05 z dnia 27.01.2025 r. | na podstawie testu Hach Lange nr LCK 238, 338","norm_bases":["PB-08 wyd. 05 z dnia 27.01.2025 r.","na podstawie testu Hach Lange nr LCK 238, 338"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu ogólnego\nZakres (5,0 – 200) mg/l\nMetoda spektrofotometryczna PB-08 wyd. 05 z dnia 27.01.2025 r. | na podstawie testu Hach Lange nr LCK 238, 338 Scieki Stezenie azotu ogolnego\nZakres (5,0 – 200) mg/l\nMetoda spektrofotometryczna PB-08 wyd. 05 z dnia 27.01.2025 r. | na podstawie testu Hach Lange nr LCK 238, 338","categories":["water"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Total nitrogen concentration Spectrophotometric method Range PB-08 wyd. 05 z dnia 27.01.2025 r. | na podstawie testu Hach Lange nr LCK 238, 338","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 200) mg/l"}],"search_zh":"污水 总氮浓度 分光光度法 范围 PB-08 wyd. 05 z dnia 27.01.2025 r. | na podstawie testu Hach Lange nr LCK 238, 338","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a5e783e4cc76d93cba39ad6","lab_id":"69ad52a3de79e566650fb662","country":"PL","accr_number":"AB 1248","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura","methodology_en":"Sampling for chemical and physical testing Temperature","parameters":[{"name":"Zakres","range":"(5,0 – 25,0)°C"}],"parameters_en":[{"name":"Range","range":"(5,0 – 25,0)°C"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura\nZakres (5,0 – 25,0)°C","reference":"PN ISO 5667-5:2017-10 | PB-11 wyd. 04 z dnia 27.01.2025 r","norm_bases":["PN ISO 5667-5:2017-10","PB-11 wyd. 04 z dnia 27.01.2025 r"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych Temperatura\nZakres (5,0 – 25,0)°C PN ISO 5667-5:2017-10 | PB-11 wyd. 04 z dnia 27.01.2025 r Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych Temperatura\nZakres (5,0 – 25,0)°C PN ISO 5667-5:2017-10 | PB-11 wyd. 04 z dnia 27.01.2025 r","categories":["water"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Sampling for chemical and physical testing Temperature Range PN ISO 5667-5:2017-10 | PB-11 wyd. 04 z dnia 27.01.2025 r","parameters_zh":[{"name":"范围","range":"(5,0 – 25,0)°C"}],"search_zh":"生活饮用水 化学和物理检测采样 温度 范围 PN ISO 5667-5:2017-10 | PB-11 wyd. 04 z dnia 27.01.2025 r","test_object_zh":"生活饮用水","methodology_zh":"化学和物理检测采样 温度"},{"_id":"6a5e783e4cc76d93cba39ad7","lab_id":"69ad52a3de79e566650fb662","country":"PL","accr_number":"AB 1248","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[{"name":"Temperatura"},{"name":"Zakres","range":"(5,0 – 25,0)°C"}],"parameters_en":[{"name":"Temperature"},{"name":"Range","range":"(5,0 – 25,0)°C"}],"technique":"Metoda manualna","techniques":["Metoda manualna"],"technique_en":"Manual method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (5,0 – 25,0)°C\nMetoda manualna","reference":"PN-ISO 5667-10:2021-11 | PB-11 wyd. 04 z dnia 27.01.2025 r.","norm_bases":["PN-ISO 5667-10:2021-11","PB-11 wyd. 04 z dnia 27.01.2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (5,0 – 25,0)°C\nMetoda manualna PN-ISO 5667-10:2021-11 | PB-11 wyd. 04 z dnia 27.01.2025 r. Scieki Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (5,0 – 25,0)°C\nMetoda manualna PN-ISO 5667-10:2021-11 | PB-11 wyd. 04 z dnia 27.01.2025 r.","categories":["water"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Sampling for chemical and physical testing Manual method Temperature Range PN-ISO 5667-10:2021-11 | PB-11 wyd. 04 z dnia 27.01.2025 r.","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"温度"},{"name":"范围","range":"(5,0 – 25,0)°C"}],"search_zh":"污水 化学与物理检测用样品采集 手工法 温度 范围 PN-ISO 5667-10:2021-11 | PB-11 wyd. 04 z dnia 27.01.2025 r.","test_object_zh":"污水","technique_zh":"手工法"}],"has_pdf":true}