🇵🇱 SIEĆ BADAWCZA ŁUKASIEWICZ – INSTYTUT METALI NIEŻELAZNYCH PL
Water & wastewater
SIEĆ BADAWCZA ŁUKASIEWICZ – INSTYTUT METALI NIEŻELAZNYCH is a laboratory accredited by PCA under number AB 124 (Gliwice, Poland). Its accreditation scope covers 39 test methods in the following areas: Water & wastewater. Test objects include: Rechargeable electrical energy storage system (REESS), Cells and batteries, Primary cells and batteries, Primary cells and batteries, Secondary acid cells and batteries, Se…. Most frequently used techniques: Test method: exposure of the tested objects to the above conditions…, Direct measurement method, Test method: exposure of the tested objects to the above conditions….
At a glance
- Accreditation number: PCA AB 124
- Methods in scope: 39
- Types of test objects: 8
- Techniques used: 3
- City: Gliwice, Poland
- Accreditation number
- AB 124
- Accreditation body
- PCA
- Address
- ul. Sowińskiego 5, 44-100 Gliwice, SIEĆ BADAWCZA ŁUKASIEWICZ – IMN ODDZIAŁ W POZNANIU, Laboratorium Badań Chemicznych Źródeł Prądu
- City
- Gliwice, Poland
What this laboratory tests (8)
- Rechargeable electrical energy storage system (REESS) — 20 methods
- Cells and batteries — 5 methods
- Primary cells and batteries — 5 methods
- Primary cells and batteries, Secondary acid cells and batteries, Secondary alkaline cells and batteries — 3 methods
- Primary cells and batteries, Secondary alkaline cells and batteries — 2 methods
- Secondary alkaline cells and batteries — 2 methods
- Secondary acid (lead-acid) cells and batteries — 1 method
- Secondary acid cells and batteries, Secondary alkaline cells and batteries — 1 method
Analytical techniques used (3)
- Test method: exposure of the tested objects to the above conditions in a climatic chamber — 2 methods
- Direct measurement method — 1 method
- Test method: exposure of the tested objects to the above conditions in a vacuum chamber — 1 method
Laboratory locations
- Laboratorium Badań Chemicznych Źródeł Prądu — AB 124 ul. Forteczna 12
- punkt 4.1, 7.1 —
- punkt 7.2.1, 7.3.6, 7.3.7 —
- punkt 7.5, 7.6, 7.8 —
- punkt 7.2.3, 7.2.4, 7.3.5 —
- punkt 7.2.2, 7.3.4 —
- punkt 6.4.2 (test T.2) —
- punkt 7.2.4, 8.2.4 —
- punkt 6.4.2.2 —
- punkt 7.3.1, 7.3.2 —
- punkt 6.4.5 (Test T.5) —
- punkt 7.2.3, 7.3.3 —
- punkt 7.9 —
- punkt 6.1.5 —
- punkt 6.4.3 —
- punkt 6.5.1 —
- punkt 6.6.2 —
- punkt 6.6.3 —
- punkt 6.6.4 —
Accreditation scope — test methods (39)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Chemical Power Sources Testing Laboratory | |||||
| 1 | Primary cells and batteries | Dimensions Range (0,5 - 630) mm |
PN-EN IEC 60086-2:2022-01 | PN-EN IEC 60086-2:2022-01/AC:2026-06 | PN-EN IEC 60086-3:2022-01 punkt 4.1, 7.1 | PN-EN IEC 60086-3:2022-01/AC:2023-10 | ||
| 2 | Primary cells and batteries | Maximum no-load voltage Range (0,1 - 100) V |
PN-EN IEC 60086-1:2022-01 punkt 5.5 | PN-EN IEC 60086-1:2022-01/AC:2022-10 | ||
| 3 | Primary cells and batteries | Discharge Range 0,05 mA do 1500 A |
PN-EN IEC 60086-1:2022-01 punkt 5.3 | PN-EN IEC 60086-1:2022-01/AC:2022-10 | PN-EN IEC 60086-2:2022-01 | PN-EN IEC 60086-2:2022-01/AC:2026-06 | PN-EN IEC 60086-3:2022-01 punkt 7.2 | PN-EN IEC 60086-3:2022-01/AC:2023-10 | ||
| 4 | Primary cells and batteries | Resistance to electrolyte leakage and deformation | PN-EN IEC 60086-1:2022-01 punkt 5.8 | PN-EN IEC 60086-1:2022-01/AC:2022-10 | ||
| 5 | Primary cells and batteries | Electrical testing Measured quantities: current intensity voltage current 2 mA - 1500 A voltage (0,1 - 800) V Test technique consisting in discharging cells and batteries at constant current or constant voltage. Electrical characteristics: discharge forced discharge |
PN-EN IEC 60086-4:2026-02 punkt 6.5.5, 6.5.10 | PN-EN IEC 60086-5:2022-06 | PN-EN IEC 60086-5:2022-06/AC:2022-08 | PN-EN IEC 62281:2019-08 punkt 6.5.2 (Test T.8) | PN-EN IEC 62281:2019-08/A1:2021-11 | PN-EN IEC 62281:2019-08/A2:2023-12 | ||
| 6 | Secondary acid (lead-acid) cells and batteries | Electrical testing Measured quantities: current intensity voltage current 0,05 mA - 1500 A voltage (0,1 - 100) V Test technique consisting in charging batteries at constant current or constant voltage and discharging at constant current, constant voltage or constant power Electrical characteristics: max. permissible discharge current cyclic resistance (durability) corrosion resistance capacity (discharge) short-circuit current and internal resistance suitability for standby operation (charging) charge acceptance after deep discharge high-current discharge charge acceptance starting capability charge retention capability (self-discharge) water consumption (loading) |
PN-EN 50342-1:2016-01 punkt 6.1 ÷ 6.4, 6.6, 6.7, 6.9 | PN-EN 50342-1:2016-01/A1:2019-01 | IEC 60095-1:2018-11 punkt 9.1 ÷ 9.7 | PN-EN 60254-1:2010 punkt 5.2 ÷ 5.5 | PN-EN 60896-11:2007 punkt 14 ÷ 16,18,19 | PN-EN 60896-21:2007 punkt 6.3, 6.11 ÷ 6.14 | PN-EN 60896-22:2007 | PN-EN 61056-1:2013-05 punkt 7.1 ÷ 7.9 | PN-E-83013:1998 | ||
| 7 | Secondary alkaline cells and batteries | Electrical testing Measured quantities: current intensity voltage current 2 mA - 1500 A voltage (0,1 - 800) V Test technique consisting in charging cells and batteries at constant current or constant voltage and discharging at constant current, constant voltage or constant power Electrical characteristics: operation of the safety device constant voltage charging cyclic resistance (durability) current at declared power overcharging charge acceptance at constant voltage charge acceptance at constant current internal resistance charging stability discharge starting capability charge retention capability (self-discharge) |
PN-EN 2570:2001 punkt 5.3.7, 5.4.1, 5.4.4, 5.4.5 | PN-EN 60622:2007 punkt 4 | PN-EN 60623:2017-07 punkt 7 | PN-EN 60952-1:2014-02 punkt 5 | PN-EN 61951-1:2017-10 punkt 7 | PN-EN 61951-1:2017-10/A1:2023-11 | PN-EN 61951-2:2017-10 punkt 7 | PN-EN 61951-2:2017-10/A1:2023-08 | PN-EN 61960-3:2017-08 punkt 7 | PN-EN 62133-1:2017-08 punkt 7.2.1, 7.3.8 , 7.3.9 | PN-EN 62133-2:2017-08 punkt 7.2.1, 7.3.6, 7.3.7 | PN-EN 62133-2:2017-08/A1:2022-04 | PN-EN 62259:2004 punkt 7.1, 7.2, 7.3, 7.4, 7.5, 7.7, 7.10 | PN-EN IEC 62281:2019-08 punkt 6.5.1 (test T.7) punkt 6.5.2 (test T.8) | PN-EN IEC 62281:2019-08/A1:2021-11 | PN-EN IEC 62281:2019-08/A2:2023-12 | PN-EN IEC 62619:2023-02 punkt 7.2.6, 8.2.2, 8.2.3 | PN-EN 62620:2015-05 punkt 6.3.1 6.4, 6.6.1, 6.6.2 | PN-EN 62620:2015-05/A1:2024-02 | PN-EN 62660-2:2019-04 punkt 6.4.2, 6.4.3 | PN-EN IEC 63056:2020-12 | PN-EN IEC 63056:2020-12/AC:2021-09 punkt 7.5, 7.6, 7.8 | ||
| 8 | Primary cells and batteries, Secondary acid cells and batteries, Secondary alkaline cells and batteries | Climatic / thermal testing Resistance to: cyclic temperature changes reduced temperature elevated temperature thermal shock Range (-70 do + 180)oC |
Test method: exposure of the tested objects to the above conditions in a climatic chamber | PN-EN 2570:2001 punkt 5.3.1 | PN-EN IEC 60086-3:2022-01 punkt 7.3.2 | PN-EN IEC 60086-3:2022-01/AC:2023-10 | PN-EN IEC 60086-4:2026-02 punkt 6.4.2, 6.5.8 | PN-EN IEC 60086-5:2022-06 punkt 6.3.2.4 | PN-EN IEC 60086-5:2022-06/AC:2022-08 | PN-EN 60068-2-1:2009 | PN-EN 60068-2-2:2009 | PN-EN IEC 60068-2-14:2024-04 | PN-EN 62133-1:2017-08 punkt 7.2.3, 7.2.4, 7.3.5 | PN-EN 62133-2:2017-08 punkt 7.2.2, 7.3.4 | PN-EN 62133-2:2017-08/A1:2022-04 | PN-EN IEC 62281:2019-08 punkt 6.4.2 (test T.2) | PN-EN IEC 62281:2019-08/A1:2021-11 | PN-EN IEC 62281:2019-08/A2:2023-12 | PN-EN IEC 62619:2023-02 punkt 7.2.4, 8.2.4 | PN-EN IEC 62660-2:2019-04 punkt 6.3.1 | |
| 9 | Primary cells and batteries, Secondary acid cells and batteries, Secondary alkaline cells and batteries | Climatic testing / humidity Resistance to: increased humidity Range (20 - 98)% wilgotności |
Test method: exposure of the tested objects to the above conditions in a climatic chamber | PN-EN 2570:2001 punkt 5.3.4 | |
| 10 | Primary cells and batteries, Secondary acid cells and batteries, Secondary alkaline cells and batteries | Climatic testing / pressure Resistance to: reduced pressure Range (2 - 20) kPa |
Test method: exposure of the tested objects to the above conditions in a vacuum chamber | PN-EN 2570:2001 punkt 5.3.2 | PN-EN IEC 60086-4:2026-02 punkt 6.4.1 | PN-EN 62133-1:2017-08 punkt 7.3.7 | PN-EN IEC 62281:2019-08 punkt 6.4.1 (Test T.1) | PN-EN IEC 62281:2019-08/A1:2021-11 | PN-EN IEC 62281:2019-08/A2:2023-12 | |
| 11 | Secondary alkaline cells and batteries | Dimensions Range (0,5 - 630) mm |
PN-EN 2570:2001 punkt 5.2.1.3 | PN-EN 60622:2007 punkt 3 | PN-EN 60623:2017-07 punkt 6 | PN-EN 61951-1:2017-10 punkt 6 | PN-EN 61951-1 :2017-10/A1:2023-11 | PN-EN 61951-2 :2017-10 punkt 6 | PN-EN 61951-2 :2017-10/A1:2023-08 | ||
| 12 | Secondary acid cells and batteries, Secondary alkaline cells and batteries | Insulation resistance Range (1 - 100) MΩ |
PN-EN 60952-1:2014-02 punkt 5.9 | PN-EN 2570:2001 punkt 5.4.8 | ||
| 13 | Primary cells and batteries, Secondary alkaline cells and batteries | Resistance to external short circuit | PN-EN IEC 60086-4:2026-02 punkt 6.5.2 | PN-EN IEC 60086-5:2022-06 punkt 6.4.2.2 | PN-EN IEC 60086-5:2022-06/AC:2022-08 | PN-EN 62133-1:2017-08 punkt 7.3.2 | PN-EN 62133-2:2017-08 punkt 7.3.1, 7.3.2 | PN-EN 62133-2:2017-08/A1:2022-04 | PN-EN IEC 62281:2019-08 punkt 6.4.5 (Test T.5) | PN-EN IEC 62281:2019-08/A1:2021-11 | PN-EN IEC 62281:2019-08/A2:2023-12 | PN-EN IEC 62619:2023-02 punkt 7.2.1 | PN-EN IEC 62660-2:2019-04 punkt 6.4.1 | ||
| 14 | Primary cells and batteries, Secondary alkaline cells and batteries | Mechanical testing: free fall |
Direct measurement method | PN-EN IEC 60086-4:2026-02 punkt 6.5.7 | PN-EN 60086-5:2022-06 punkt 6.4.2.4 | PN-EN 60086-5:2022-06/AC:2022-08 | PN-EN 62133-1:2017-08 punkt 7.3.3 | PN-EN 62133-2:2017-08 punkt 7.3.3 | PN-EN 62133-2:2017-08/A1:2022-04 | PN-EN IEC 62619:2023-02 punkt 7.2.3, 7.3.3 | PN-EN IEC 63056:2020-12 | PN-EN IEC 63056:2020-12/AC:2021-09 punkt 7.9 | |
| 15 | Rechargeable electrical energy storage system (REESS) | Standard cycle | Regulamin EKG ONZ nr 100 Załącznik 9 | ||
| 16 | Rechargeable electrical energy storage system (REESS) | Resistance to rapid temperature changes and thermal cycling test | Regulamin EKG ONZ nr 100 Załącznik 9B | ||
| 17 | Rechargeable electrical energy storage system (REESS) | Fire resistance | Regulamin EKG ONZ nr 100 Załącznik 9E | ||
| 18 | Rechargeable electrical energy storage system (REESS) | Resistance to external short circuit | Regulamin EKG ONZ nr 100 Załącznik 9F | ||
| 19 | Rechargeable electrical energy storage system (REESS) | Resistance to overcharging | Regulamin EKG ONZ nr 100 Załącznik 9G | ||
| 20 | Rechargeable electrical energy storage system (REESS) | Protection against excessive discharge | Regulamin EKG ONZ nr 100 Załącznik 9H | ||
| 21 | Rechargeable electrical energy storage system (REESS) | Standard cycle | Regulamin EKG ONZ nr 136 Załącznik 8 | ||
| 22 | Rechargeable electrical energy storage system (REESS) | Resistance to rapid temperature changes and thermal cycling test | Regulamin EKG ONZ nr 136 Załącznik 8B | ||
| 23 | Rechargeable electrical energy storage system (REESS) | Resistance to the mechanical drop test of a rented REESS | Regulamin EKG ONZ nr 136 Załącznik 8C | ||
| 24 | Rechargeable electrical energy storage system (REESS) | Fire resistance | Regulamin EKG ONZ nr 136 Załącznik 8E | ||
| 25 | Rechargeable electrical energy storage system (REESS) | Resistance to external short circuit | Regulamin EKG ONZ nr 136 Załącznik 8F | ||
| 26 | Rechargeable electrical energy storage system (REESS) | Resistance to overcharging | Regulamin EKG ONZ nr 136 Załącznik 8G | ||
| 27 | Rechargeable electrical energy storage system (REESS) | Protection against excessive discharge | Regulamin EKG ONZ nr 136 Załącznik 8H | ||
| 28 | Rechargeable electrical energy storage system (REESS) | Standard cycle | ISO 6469-1:2019-04 | ISO 6469-1:2019/Amd.1:2022-11 punkt 6.1.5 | ||
| 29 | Rechargeable electrical energy storage system (REESS) | Resistance to rapid temperature changes and thermal cycling test | ISO 6469-1:2019-04 | ISO 6469-1:2019/Amd.1:2022-11 punkt 6.3.1 | ||
| 30 | Rechargeable electrical energy storage system (REESS) | Fire resistance | ISO 6469-1:2019-04 | ISO 6469-1:2019/Amd.1:2022-11 punkt 6.4.3 | ||
| 31 | Rechargeable electrical energy storage system (REESS) | Resistance to external short circuit | ISO 6469-1:2019-04 | ISO 6469-1:2019/Amd.1:2022-11 punkt 6.5.1 | ||
| 32 | Rechargeable electrical energy storage system (REESS) | Resistance to overcharging | ISO 6469-1:2019-04 | ISO 6469-1:2019/Amd.1:2022-11 punkt 6.6.2 | ||
| 33 | Rechargeable electrical energy storage system (REESS) | Protection against excessive discharge | ISO 6469-1:2019-04 | ISO 6469-1:2019/Amd.1:2022-11 punkt 6.6.3 | ||
| 34 | Rechargeable electrical energy storage system (REESS) | Protection against internal overheating | ISO 6469-1:2019-04 | ISO 6469-1:2019/Amd.1:2022-11 punkt 6.6.4 | ||
| 35 | Cells and batteries | T.1 Altitude simulation | Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8/Amed.1 | ||
| 36 | Cells and batteries | T.2 Thermal test | Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8/Amed.1 | ||
| 37 | Cells and batteries | T.5 External short circuit | Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8/Amed.1 | ||
| 38 | Cells and batteries | T.7 Overcharge | Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8/Amed.1 | ||
| 39 | Cells and batteries | T.8 Forced discharge | Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8/Amed.1 | ||
Reference standards (106)
IEC 60095-1:2018-11 punkt 9.1 ÷ 9.7
ISO 6469-1:2019-04
ISO 6469-1:2019/Amd.1:2022-11 punkt 6.1.5
ISO 6469-1:2019/Amd.1:2022-11 punkt 6.3.1
ISO 6469-1:2019/Amd.1:2022-11 punkt 6.4.3
ISO 6469-1:2019/Amd.1:2022-11 punkt 6.5.1
ISO 6469-1:2019/Amd.1:2022-11 punkt 6.6.2
ISO 6469-1:2019/Amd.1:2022-11 punkt 6.6.3
ISO 6469-1:2019/Amd.1:2022-11 punkt 6.6.4
PN-E-83013:1998
PN-EN 2570:2001 punkt 5.2.1.3
PN-EN 2570:2001 punkt 5.3.1
PN-EN 2570:2001 punkt 5.3.2
PN-EN 2570:2001 punkt 5.3.4
PN-EN 2570:2001 punkt 5.3.7, 5.4.1, 5.4.4, 5.4.5
PN-EN 2570:2001 punkt 5.4.8
PN-EN 50342-1:2016-01 punkt 6.1 ÷ 6.4, 6.6, 6.7, 6.9
PN-EN 50342-1:2016-01/A1:2019-01
PN-EN 60068-2-1:2009
PN-EN 60068-2-2:2009
PN-EN 60086-5:2022-06 punkt 6.4.2.4
PN-EN 60086-5:2022-06/AC:2022-08
PN-EN 60254-1:2010 punkt 5.2 ÷ 5.5
PN-EN 60622:2007 punkt 3
PN-EN 60622:2007 punkt 4
PN-EN 60623:2017-07 punkt 6
PN-EN 60623:2017-07 punkt 7
PN-EN 60896-11:2007 punkt 14 ÷ 16,18,19
PN-EN 60896-21:2007 punkt 6.3, 6.11 ÷ 6.14
PN-EN 60896-22:2007
PN-EN 60952-1:2014-02 punkt 5
PN-EN 60952-1:2014-02 punkt 5.9
PN-EN 61056-1:2013-05 punkt 7.1 ÷ 7.9
PN-EN 61951-1 :2017-10/A1:2023-11
PN-EN 61951-1:2017-10 punkt 6
PN-EN 61951-1:2017-10 punkt 7
PN-EN 61951-1:2017-10/A1:2023-11
PN-EN 61951-2 :2017-10 punkt 6
PN-EN 61951-2 :2017-10/A1:2023-08
PN-EN 61951-2:2017-10 punkt 7
PN-EN 61951-2:2017-10/A1:2023-08
PN-EN 61960-3:2017-08 punkt 7
PN-EN 62133-1:2017-08 punkt 7.2.1, 7.3.8 , 7.3.9
PN-EN 62133-1:2017-08 punkt 7.2.3, 7.2.4, 7.3.5
PN-EN 62133-1:2017-08 punkt 7.3.2
PN-EN 62133-1:2017-08 punkt 7.3.3
PN-EN 62133-1:2017-08 punkt 7.3.7
PN-EN 62133-2:2017-08 punkt 7.2.1, 7.3.6, 7.3.7
PN-EN 62133-2:2017-08 punkt 7.2.2, 7.3.4
PN-EN 62133-2:2017-08 punkt 7.3.1, 7.3.2
PN-EN 62133-2:2017-08 punkt 7.3.3
PN-EN 62133-2:2017-08/A1:2022-04
PN-EN 62259:2004 punkt 7.1, 7.2, 7.3, 7.4, 7.5, 7.7, 7.10
PN-EN 62620:2015-05 punkt 6.3.1 6.4, 6.6.1, 6.6.2
PN-EN 62620:2015-05/A1:2024-02
PN-EN 62660-2:2019-04 punkt 6.4.2, 6.4.3
PN-EN IEC 60068-2-14:2024-04
PN-EN IEC 60086-1:2022-01 punkt 5.3
PN-EN IEC 60086-1:2022-01 punkt 5.5
PN-EN IEC 60086-1:2022-01 punkt 5.8
PN-EN IEC 60086-1:2022-01/AC:2022-10
PN-EN IEC 60086-2:2022-01
PN-EN IEC 60086-2:2022-01/AC:2026-06
PN-EN IEC 60086-3:2022-01 punkt 4.1, 7.1
PN-EN IEC 60086-3:2022-01 punkt 7.2
PN-EN IEC 60086-3:2022-01 punkt 7.3.2
PN-EN IEC 60086-3:2022-01/AC:2023-10
PN-EN IEC 60086-4:2026-02 punkt 6.4.1
PN-EN IEC 60086-4:2026-02 punkt 6.4.2, 6.5.8
PN-EN IEC 60086-4:2026-02 punkt 6.5.2
PN-EN IEC 60086-4:2026-02 punkt 6.5.5, 6.5.10
PN-EN IEC 60086-4:2026-02 punkt 6.5.7
PN-EN IEC 60086-5:2022-06
PN-EN IEC 60086-5:2022-06 punkt 6.3.2.4
PN-EN IEC 60086-5:2022-06 punkt 6.4.2.2
PN-EN IEC 60086-5:2022-06/AC:2022-08
PN-EN IEC 62281:2019-08 punkt 6.4.1 (Test T.1)
PN-EN IEC 62281:2019-08 punkt 6.4.2 (test T.2)
PN-EN IEC 62281:2019-08 punkt 6.4.5 (Test T.5)
PN-EN IEC 62281:2019-08 punkt 6.5.1 (test T.7) punkt 6.5.2 (test T.8)
PN-EN IEC 62281:2019-08 punkt 6.5.2 (Test T.8)
PN-EN IEC 62281:2019-08/A1:2021-11
PN-EN IEC 62281:2019-08/A2:2023-12
PN-EN IEC 62619:2023-02 punkt 7.2.1
PN-EN IEC 62619:2023-02 punkt 7.2.3, 7.3.3
PN-EN IEC 62619:2023-02 punkt 7.2.4, 8.2.4
PN-EN IEC 62619:2023-02 punkt 7.2.6, 8.2.2, 8.2.3
PN-EN IEC 62660-2:2019-04 punkt 6.3.1
PN-EN IEC 62660-2:2019-04 punkt 6.4.1
PN-EN IEC 63056:2020-12
PN-EN IEC 63056:2020-12/AC:2021-09 punkt 7.5, 7.6, 7.8
PN-EN IEC 63056:2020-12/AC:2021-09 punkt 7.9
Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8/Amed.1
Regulamin EKG ONZ nr 100 Załącznik 9
Regulamin EKG ONZ nr 100 Załącznik 9B
Regulamin EKG ONZ nr 100 Załącznik 9E
Regulamin EKG ONZ nr 100 Załącznik 9F
Regulamin EKG ONZ nr 100 Załącznik 9G
Regulamin EKG ONZ nr 100 Załącznik 9H
Regulamin EKG ONZ nr 136 Załącznik 8
Regulamin EKG ONZ nr 136 Załącznik 8B
Regulamin EKG ONZ nr 136 Załącznik 8C
Regulamin EKG ONZ nr 136 Załącznik 8E
Regulamin EKG ONZ nr 136 Załącznik 8F
Regulamin EKG ONZ nr 136 Załącznik 8G
Regulamin EKG ONZ nr 136 Załącznik 8H