{"lab":{"_id":"69ad52a3de79e566650fb12b","country":"PL","accr_number":"AB 124","accr_body":"PCA","address":"ul. Sowińskiego 5, 44-100 Gliwice, SIEĆ BADAWCZA ŁUKASIEWICZ – IMN ODDZIAŁ W POZNANIU, Laboratorium Badań Chemicznych Źródeł Prądu","categories":["construction"],"city":"Gliwice","imported_at":"2026-03-08T10:42:43.265Z","methods_count":39,"name":"SIEĆ BADAWCZA ŁUKASIEWICZ – INSTYTUT METALI NIEŻELAZNYCH","parse_status":"parsed","parse_version":2,"pdf_files":["AB_124.pdf"],"scope_summary":"","search_text":"sieć badawcza łukasiewicz – instytut metali nieżelaznych ul. sowińskiego 5, 44-100 gliwice, sieć badawcza łukasiewicz – imn oddział w poznaniu, laboratorium badań chemicznych źródeł prądu other pharma electronics water construction petro metrology","status":"active","updated_at":"2026-03-08T14:50:24.924Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T07:58:51.323Z","email_confidence":"high","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%20124,plik.html","parse_date":"2026-08-13T07:58:51.323Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"E/6","pl":"Badania elektryczne wyrobów elektrycznych","en":"Electric tests of electrical products"},{"codes":"N/6","pl":"Badania właściwości fizycznych wyrobów elektrycznych","en":"Tests of physical properties of electrical products"},{"codes":"J/6","pl":"Badania mechaniczne wyrobów elektrycznych","en":"Mechanical tests of electrical products"},{"codes":"H/6","pl":"Badania ogniowe wyrobów elektrycznych","en":"Fire tests of electrical products"}],"issue":{"no":"27","date":"27.07.2026"},"map_coord":[50.295789,18.633954],"map_geo":"nominatim-street","lab_locations":[{"name":"Laboratorium Badań Chemicznych Źródeł Prądu","address":"AB 124 ul. Forteczna 12","city":null,"postal":null},{"name":"punkt 4.1, 7.1","address":null,"city":null,"postal":null},{"name":"punkt 7.2.1, 7.3.6, 7.3.7","address":null,"city":null,"postal":null},{"name":"punkt 7.5, 7.6, 7.8","address":null,"city":null,"postal":null},{"name":"punkt 7.2.3, 7.2.4, 7.3.5","address":null,"city":null,"postal":null},{"name":"punkt 7.2.2, 7.3.4","address":null,"city":null,"postal":null},{"name":"punkt 6.4.2 (test T.2)","address":null,"city":null,"postal":null},{"name":"punkt 7.2.4, 8.2.4","address":null,"city":null,"postal":null},{"name":"punkt 6.4.2.2","address":null,"city":null,"postal":null},{"name":"punkt 7.3.1, 7.3.2","address":null,"city":null,"postal":null},{"name":"punkt 6.4.5 (Test T.5)","address":null,"city":null,"postal":null},{"name":"punkt 7.2.3, 7.3.3","address":null,"city":null,"postal":null},{"name":"punkt 7.9","address":null,"city":null,"postal":null},{"name":"punkt 6.1.5","address":null,"city":null,"postal":null},{"name":"punkt 6.4.3","address":null,"city":null,"postal":null},{"name":"punkt 6.5.1","address":null,"city":null,"postal":null},{"name":"punkt 6.6.2","address":null,"city":null,"postal":null},{"name":"punkt 6.6.3","address":null,"city":null,"postal":null},{"name":"punkt 6.6.4","address":null,"city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/6f057ce7dadf3dfd6a31df6c8255030b/AB%20124.pdf","has_en":true,"category_counts":{"other":37,"construction":1,"water":1},"category_scores":{"other":35.1,"construction":0.03,"water":0.03},"has_zh":true,"lab_locations_zh":[{"name":"化学电源检测实验室","address":"AB 124 ul. Forteczna 12","city":null,"postal":null},{"name":"punkt 4.1, 7.1","address":null,"city":null,"postal":null},{"name":"punkt 7.2.1, 7.3.6, 7.3.7","address":null,"city":null,"postal":null},{"name":"punkt 7.5, 7.6, 7.8","address":null,"city":null,"postal":null},{"name":"punkt 7.2.3, 7.2.4, 7.3.5","address":null,"city":null,"postal":null},{"name":"punkt 7.2.2, 7.3.4","address":null,"city":null,"postal":null},{"name":"punkt 6.4.2 (test T.2)","address":null,"city":null,"postal":null},{"name":"punkt 7.2.4, 8.2.4","address":null,"city":null,"postal":null},{"name":"punkt 6.4.2.2","address":null,"city":null,"postal":null},{"name":"punkt 7.3.1, 7.3.2","address":null,"city":null,"postal":null},{"name":"punkt 6.4.5 (Test T.5)","address":null,"city":null,"postal":null},{"name":"punkt 7.2.3, 7.3.3","address":null,"city":null,"postal":null},{"name":"punkt 7.9","address":null,"city":null,"postal":null},{"name":"punkt 6.1.5","address":null,"city":null,"postal":null},{"name":"punkt 6.4.3","address":null,"city":null,"postal":null},{"name":"punkt 6.5.1","address":null,"city":null,"postal":null},{"name":"punkt 6.6.2","address":null,"city":null,"postal":null},{"name":"punkt 6.6.3","address":null,"city":null,"postal":null},{"name":"punkt 6.6.4","address":null,"city":null,"postal":null}]},"methods":[{"_id":"6a7d793b0636ba417e41a7ae","lab_id":"69ad52a3de79e566650fb12b","country":"PL","accr_number":"AB 124","accr_body":"PCA","test_object":"Ogniwa i baterie pierwotne","methodology":"Wymiary","parameters":[{"name":"Zakres","range":"(0,5 - 630) mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Wymiary\nZakres (0,5 - 630) mm","reference":"PN-EN IEC 60086-2:2022-01 | PN-EN IEC 60086-2:2022-01/AC:2026-06 | PN-EN IEC 60086-3:2022-01 punkt 4.1, 7.1 | PN-EN IEC 60086-3:2022-01/AC:2023-10","norm_bases":["PN-EN IEC 60086-2:2022-01","PN-EN IEC 60086-2:2022-01/AC:2026-06","PN-EN IEC 60086-3:2022-01 punkt 4.1, 7.1","PN-EN IEC 60086-3:2022-01/AC:2023-10"],"lab_section":"Laboratorium Badań Chemicznych Źródeł Prądu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ogniwa i baterie pierwotne Wymiary\nZakres (0,5 - 630) mm PN-EN IEC 60086-2:2022-01 | PN-EN IEC 60086-2:2022-01/AC:2026-06 | PN-EN IEC 60086-3:2022-01 punkt 4.1, 7.1 | PN-EN IEC 60086-3:2022-01/AC:2023-10 Ogniwa i baterie pierwotne Wymiary\nZakres (0,5 - 630) mm PN-EN IEC 60086-2:2022-01 | PN-EN IEC 60086-2:2022-01/AC:2026-06 | PN-EN IEC 60086-3:2022-01 punkt 4.1, 7.1 | PN-EN IEC 60086-3:2022-01/AC:2023-10","categories":["other"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Power Sources Testing Laboratory","methodology_en":"Dimensions","parameters_en":[{"name":"Range","range":"(0,5 - 630) mm"}],"search_en":"Primary cells and batteries Dimensions Chemical Power Sources Testing Laboratory Range PN-EN IEC 60086-2:2022-01 | PN-EN IEC 60086-2:2022-01/AC:2026-06 | PN-EN IEC 60086-3:2022-01 punkt 4.1, 7.1 | PN-EN IEC 60086-3:2022-01/AC:2023-10","test_object_en":"Primary cells and batteries","parameters_zh":[{"name":"范围","range":"(0,5 - 630) mm"}],"search_zh":"原电池与电池组 尺寸 化学电源检测实验室 范围 PN-EN IEC 60086-2:2022-01 | PN-EN IEC 60086-2:2022-01/AC:2026-06 | PN-EN IEC 60086-3:2022-01 punkt 4.1, 7.1 | PN-EN IEC 60086-3:2022-01/AC:2023-10","methodology_zh":"尺寸","lab_section_zh":"化学电源检测实验室","test_object_zh":"原电池与电池组"},{"_id":"6a7d793b0636ba417e41a7af","lab_id":"69ad52a3de79e566650fb12b","country":"PL","accr_number":"AB 124","accr_body":"PCA","test_object":"Ogniwa i baterie pierwotne","methodology":"Maksymalne napięcie bez obciążenia","parameters":[{"name":"Zakres","range":"(0,1 - 100) V"}],"technique":null,"techniques":[],"computed":[],"activity":"Maksymalne napięcie bez obciążenia\nZakres (0,1 - 100) V","reference":"PN-EN IEC 60086-1:2022-01 punkt 5.5 | PN-EN IEC 60086-1:2022-01/AC:2022-10","norm_bases":["PN-EN IEC 60086-1:2022-01 punkt 5.5","PN-EN IEC 60086-1:2022-01/AC:2022-10"],"lab_section":"Laboratorium Badań Chemicznych Źródeł Prądu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ogniwa i baterie pierwotne Maksymalne napięcie bez obciążenia\nZakres (0,1 - 100) V PN-EN IEC 60086-1:2022-01 punkt 5.5 | PN-EN IEC 60086-1:2022-01/AC:2022-10 Ogniwa i baterie pierwotne Maksymalne napiecie bez obciazenia\nZakres (0,1 - 100) V PN-EN IEC 60086-1:2022-01 punkt 5.5 | PN-EN IEC 60086-1:2022-01/AC:2022-10","categories":["other"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Power Sources Testing Laboratory","methodology_en":"Maximum no-load voltage","parameters_en":[{"name":"Range","range":"(0,1 - 100) V"}],"search_en":"Primary cells and batteries Maximum no-load voltage Chemical Power Sources Testing Laboratory Range PN-EN IEC 60086-1:2022-01 punkt 5.5 | PN-EN IEC 60086-1:2022-01/AC:2022-10","test_object_en":"Primary cells and batteries","parameters_zh":[{"name":"范围","range":"(0,1 - 100) V"}],"search_zh":"原电池与电池组 化学电源检测实验室 范围 PN-EN IEC 60086-1:2022-01 punkt 5.5 | PN-EN IEC 60086-1:2022-01/AC:2022-10","lab_section_zh":"化学电源检测实验室","test_object_zh":"原电池与电池组"},{"_id":"6a7d793b0636ba417e41a7b0","lab_id":"69ad52a3de79e566650fb12b","country":"PL","accr_number":"AB 124","accr_body":"PCA","test_object":"Ogniwa i baterie pierwotne","methodology":"Wyładowanie","parameters":[{"name":"Zakres","range":"0,05 mA do 1500 A"}],"technique":null,"techniques":[],"computed":[],"activity":"Wyładowanie\nZakres 0,05 mA do 1500 A","reference":"PN-EN IEC 60086-1:2022-01 punkt 5.3 | PN-EN IEC 60086-1:2022-01/AC:2022-10 | PN-EN IEC 60086-2:2022-01 | PN-EN IEC 60086-2:2022-01/AC:2026-06 | PN-EN IEC 60086-3:2022-01 punkt 7.2 | PN-EN IEC 60086-3:2022-01/AC:2023-10","norm_bases":["PN-EN IEC 60086-1:2022-01 punkt 5.3","PN-EN IEC 60086-1:2022-01/AC:2022-10","PN-EN IEC 60086-2:2022-01","PN-EN IEC 60086-2:2022-01/AC:2026-06","PN-EN IEC 60086-3:2022-01 punkt 7.2","PN-EN IEC 60086-3:2022-01/AC:2023-10"],"lab_section":"Laboratorium Badań Chemicznych Źródeł Prądu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ogniwa i baterie pierwotne Wyładowanie\nZakres 0,05 mA do 1500 A PN-EN IEC 60086-1:2022-01 punkt 5.3 | PN-EN IEC 60086-1:2022-01/AC:2022-10 | PN-EN IEC 60086-2:2022-01 | PN-EN IEC 60086-2:2022-01/AC:2026-06 | PN-EN IEC 60086-3:2022-01 punkt 7.2 | PN-EN IEC 60086-3:2022-01/AC:2023-10 Ogniwa i baterie pierwotne Wyladowanie\nZakres 0,05 mA do 1500 A PN-EN IEC 60086-1:2022-01 punkt 5.3 | PN-EN IEC 60086-1:2022-01/AC:2022-10 | PN-EN IEC 60086-2:2022-01 | PN-EN IEC 60086-2:2022-01/AC:2026-06 | PN-EN IEC 60086-3:2022-01 punkt 7.2 | PN-EN IEC 60086-3:2022-01/AC:2023-10","categories":["other"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Power Sources Testing Laboratory","methodology_en":"Discharge","parameters_en":[{"name":"Range","range":"0,05 mA do 1500 A"}],"search_en":"Primary cells and batteries Discharge Chemical Power Sources Testing Laboratory Range PN-EN IEC 60086-1:2022-01 punkt 5.3 | PN-EN IEC 60086-1:2022-01/AC:2022-10 | PN-EN IEC 60086-2:2022-01 | PN-EN IEC 60086-2:2022-01/AC:2026-06 | PN-EN IEC 60086-3:2022-01 punkt 7.2 | PN-EN IEC 60086-3:2022-01/AC:2023-10","test_object_en":"Primary cells and batteries","parameters_zh":[{"name":"范围","range":"0,05 mA do 1500 A"}],"search_zh":"原电池与电池组 化学电源检测实验室 范围 PN-EN IEC 60086-1:2022-01 punkt 5.3 | PN-EN IEC 60086-1:2022-01/AC:2022-10 | PN-EN IEC 60086-2:2022-01 | PN-EN IEC 60086-2:2022-01/AC:2026-06 | PN-EN IEC 60086-3:2022-01 punkt 7.2 | PN-EN IEC 60086-3:2022-01/AC:2023-10","lab_section_zh":"化学电源检测实验室","test_object_zh":"原电池与电池组"},{"_id":"6a7d793b0636ba417e41a7b1","lab_id":"69ad52a3de79e566650fb12b","country":"PL","accr_number":"AB 124","accr_body":"PCA","test_object":"Ogniwa i baterie pierwotne","methodology":"Odporność na wyciekanie elektrolitu i deformację","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na wyciekanie elektrolitu i deformację","reference":"PN-EN IEC 60086-1:2022-01 punkt 5.8 | PN-EN IEC 60086-1:2022-01/AC:2022-10","norm_bases":["PN-EN IEC 60086-1:2022-01 punkt 5.8","PN-EN IEC 60086-1:2022-01/AC:2022-10"],"lab_section":"Laboratorium Badań Chemicznych Źródeł Prądu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ogniwa i baterie pierwotne Odporność na wyciekanie elektrolitu i deformację PN-EN IEC 60086-1:2022-01 punkt 5.8 | PN-EN IEC 60086-1:2022-01/AC:2022-10 Ogniwa i baterie pierwotne Odpornosc na wyciekanie elektrolitu i deformacje PN-EN IEC 60086-1:2022-01 punkt 5.8 | PN-EN IEC 60086-1:2022-01/AC:2022-10","categories":["other"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Power Sources Testing Laboratory","methodology_en":"Resistance to electrolyte leakage and deformation","search_en":"Primary cells and batteries Resistance to electrolyte leakage and deformation Chemical Power Sources Testing Laboratory PN-EN IEC 60086-1:2022-01 punkt 5.8 | PN-EN IEC 60086-1:2022-01/AC:2022-10","test_object_en":"Primary cells and batteries","lab_section_zh":"化学电源检测实验室","search_zh":"原电池与电池组 化学电源检测实验室 PN-EN IEC 60086-1:2022-01 punkt 5.8 | PN-EN IEC 60086-1:2022-01/AC:2022-10","test_object_zh":"原电池与电池组"},{"_id":"6a7d793b0636ba417e41a7b2","lab_id":"69ad52a3de79e566650fb12b","country":"PL","accr_number":"AB 124","accr_body":"PCA","test_object":"Ogniwa i baterie pierwotne","methodology":"Badania elektryczne","parameters":[{"name":"Mierzone wielkości:"},{"name":"natężenie prądu"},{"name":"napięcie"},{"name":"natężenie 2 mA - 1500 A"},{"name":"napięcie","range":"(0,1 - 800) V"},{"name":"Technika badawcza polegająca na wyładowaniu ogniw i baterii stałym natężeniem prądu lub stałym napięciem. Charakterystyki elektryczne:"},{"name":"wyładowanie"},{"name":"wymuszone wyładowanie"}],"technique":null,"techniques":[],"computed":[],"activity":"Badania elektryczne\nZakres:\nMierzone wielkości:\nnatężenie prądu\nnapięcie\nnatężenie 2 mA - 1500 A\nnapięcie (0,1 - 800) V\nTechnika badawcza polegająca na wyładowaniu ogniw i baterii stałym natężeniem prądu lub stałym napięciem. Charakterystyki elektryczne:\nwyładowanie\nwymuszone wyładowanie","reference":"PN-EN IEC 60086-4:2026-02 punkt 6.5.5, 6.5.10 | PN-EN IEC 60086-5:2022-06 | PN-EN IEC 60086-5:2022-06/AC:2022-08 | PN-EN IEC 62281:2019-08 punkt 6.5.2 (Test T.8) | PN-EN IEC 62281:2019-08/A1:2021-11 | PN-EN IEC 62281:2019-08/A2:2023-12","norm_bases":["PN-EN IEC 60086-4:2026-02 punkt 6.5.5, 6.5.10","PN-EN IEC 60086-5:2022-06","PN-EN IEC 60086-5:2022-06/AC:2022-08","PN-EN IEC 62281:2019-08 punkt 6.5.2 (Test T.8)","PN-EN IEC 62281:2019-08/A1:2021-11","PN-EN IEC 62281:2019-08/A2:2023-12"],"lab_section":"Laboratorium Badań Chemicznych Źródeł Prądu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ogniwa i baterie pierwotne Badania elektryczne\nZakres:\nMierzone wielkości:\nnatężenie prądu\nnapięcie\nnatężenie 2 mA - 1500 A\nnapięcie (0,1 - 800) V\nTechnika badawcza polegająca na wyładowaniu ogniw i baterii stałym natężeniem prądu lub stałym napięciem. Charakterystyki elektryczne:\nwyładowanie\nwymuszone wyładowanie PN-EN IEC 60086-4:2026-02 punkt 6.5.5, 6.5.10 | PN-EN IEC 60086-5:2022-06 | PN-EN IEC 60086-5:2022-06/AC:2022-08 | PN-EN IEC 62281:2019-08 punkt 6.5.2 (Test T.8) | PN-EN IEC 62281:2019-08/A1:2021-11 | PN-EN IEC 62281:2019-08/A2:2023-12 Ogniwa i baterie pierwotne Badania elektryczne\nZakres:\nMierzone wielkosci:\nnatezenie pradu\nnapiecie\nnatezenie 2 mA - 1500 A\nnapiecie (0,1 - 800) V\nTechnika badawcza polegajaca na wyladowaniu ogniw i baterii stalym natezeniem pradu lub stalym napieciem. Charakterystyki elektryczne:\nwyladowanie\nwymuszone wyladowanie PN-EN IEC 60086-4:2026-02 punkt 6.5.5, 6.5.10 | PN-EN IEC 60086-5:2022-06 | PN-EN IEC 60086-5:2022-06/AC:2022-08 | PN-EN IEC 62281:2019-08 punkt 6.5.2 (Test T.8) | PN-EN IEC 62281:2019-08/A1:2021-11 | PN-EN IEC 62281:2019-08/A2:2023-12","categories":["other"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Power Sources Testing Laboratory","methodology_en":"Electrical testing","parameters_en":[{"name":"Measured quantities:"},{"name":"current intensity"},{"name":"voltage"},{"name":"current 2 mA - 1500 A"},{"name":"voltage","range":"(0,1 - 800) V"},{"name":"Test technique consisting in discharging cells and batteries at constant current or constant voltage. Electrical characteristics:"},{"name":"discharge"},{"name":"forced discharge"}],"search_en":"Primary cells and batteries Electrical testing Chemical Power Sources Testing Laboratory Measured quantities: current intensity voltage current 2 mA - 1500 A voltage Test technique consisting in discharging cells and batteries at constant current or constant voltage. Electrical characteristics: discharge forced discharge PN-EN IEC 60086-4:2026-02 punkt 6.5.5, 6.5.10 | PN-EN IEC 60086-5:2022-06 | PN-EN IEC 60086-5:2022-06/AC:2022-08 | PN-EN IEC 62281:2019-08 punkt 6.5.2 (Test T.8) | PN-EN IEC 62281:2019-08/A1:2021-11 | PN-EN IEC 62281:2019-08/A2:2023-12","test_object_en":"Primary cells and batteries","lab_section_zh":"化学电源检测实验室","search_zh":"原电池与电池组 电气检验 化学电源检测实验室 测量量： 电流强度 电压 电压 PN-EN IEC 60086-4:2026-02 punkt 6.5.5, 6.5.10 | PN-EN IEC 60086-5:2022-06 | PN-EN IEC 60086-5:2022-06/AC:2022-08 | PN-EN IEC 62281:2019-08 punkt 6.5.2 (Test T.8) | PN-EN IEC 62281:2019-08/A1:2021-11 | PN-EN IEC 62281:2019-08/A2:2023-12","parameters_zh":[{"name":"测量量："},{"name":"电流强度"},{"name":"电压"},{"name":"natężenie 2 mA - 1500 A"},{"name":"电压","range":"(0,1 - 800) V"},{"name":"Technika badawcza polegająca na wyładowaniu ogniw i baterii stałym natężeniem prądu lub stałym napięciem. Charakterystyki elektryczne:"},{"name":"wyładowanie"},{"name":"wymuszone wyładowanie"}],"test_object_zh":"原电池与电池组","methodology_zh":"电气检验"},{"_id":"6a7d793b0636ba417e41a7b3","lab_id":"69ad52a3de79e566650fb12b","country":"PL","accr_number":"AB 124","accr_body":"PCA","test_object":"Ogniwa i baterie wtórne kwasowe (ołowiowe)","methodology":"Badania elektryczne","parameters":[{"name":"Mierzone wielkości:"},{"name":"natężenie prądu"},{"name":"napięcie"},{"name":"natężenie 0,05 mA - 1500 A"},{"name":"napięcie","range":"(0,1 - 100) V"},{"name":"Technika badawcza polegająca na ładowaniu akumulatorów stałym natężeniem prądu lub stałym napięciem i wyładowaniu stałym natężeniem prądu, stałym napięciem lub stałą mocą Charakterystyki elektryczne:"},{"name":"max. dopuszczalne natężenie prądu wyładowania"},{"name":"odporność cykliczna (trwałość)"},{"name":"odporność na korozję"},{"name":"pojemność (wyładowanie)"},{"name":"prąd zwarcia i rezystancja wewnętrzna"},{"name":"przydatność do pracy rezerwowej (ładowanie)"},{"name":"przyjmowanie ładunku po głębokim wyładowaniu"},{"name":"wyładowanie wysokim prądem"},{"name":"zdolność przyjmowania ładunku"},{"name":"zdolność rozruchowa"},{"name":"zdolność zachowania ładunku (samowyładowanie)"},{"name":"zużycie wody (ładowanie)"}],"technique":null,"techniques":[],"computed":[],"activity":"Badania elektryczne\nZakres:\nMierzone wielkości:\nnatężenie prądu\nnapięcie\nnatężenie 0,05 mA - 1500 A\nnapięcie (0,1 - 100) V\nTechnika badawcza polegająca na ładowaniu akumulatorów stałym natężeniem prądu lub stałym napięciem i wyładowaniu stałym natężeniem prądu, stałym napięciem lub stałą mocą Charakterystyki elektryczne:\nmax. dopuszczalne natężenie prądu wyładowania\nodporność cykliczna (trwałość)\nodporność na korozję\npojemność (wyładowanie)\nprąd zwarcia i rezystancja wewnętrzna\nprzydatność do pracy rezerwowej (ładowanie)\nprzyjmowanie ładunku po głębokim wyładowaniu\nwyładowanie wysokim prądem\nzdolność przyjmowania ładunku\nzdolność rozruchowa\nzdolność zachowania ładunku (samowyładowanie)\nzużycie wody (ładowanie)","reference":"PN-EN 50342-1:2016-01 punkt 6.1 ÷ 6.4, 6.6, 6.7, 6.9 | PN-EN 50342-1:2016-01/A1:2019-01 | IEC 60095-1:2018-11 punkt 9.1 ÷ 9.7 | PN-EN 60254-1:2010 punkt 5.2 ÷ 5.5 | PN-EN 60896-11:2007 punkt 14 ÷ 16,18,19 | PN-EN 60896-21:2007 punkt 6.3, 6.11 ÷ 6.14 | PN-EN 60896-22:2007 | PN-EN 61056-1:2013-05 punkt 7.1 ÷ 7.9 | PN-E-83013:1998","norm_bases":["PN-EN 50342-1:2016-01 punkt 6.1 ÷ 6.4, 6.6, 6.7, 6.9","PN-EN 50342-1:2016-01/A1:2019-01","IEC 60095-1:2018-11 punkt 9.1 ÷ 9.7","PN-EN 60254-1:2010 punkt 5.2 ÷ 5.5","PN-EN 60896-11:2007 punkt 14 ÷ 16,18,19","PN-EN 60896-21:2007 punkt 6.3, 6.11 ÷ 6.14","PN-EN 60896-22:2007","PN-EN 61056-1:2013-05 punkt 7.1 ÷ 7.9","PN-E-83013:1998"],"lab_section":"Laboratorium Badań Chemicznych Źródeł Prądu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ogniwa i baterie wtórne kwasowe (ołowiowe) Badania elektryczne\nZakres:\nMierzone wielkości:\nnatężenie prądu\nnapięcie\nnatężenie 0,05 mA - 1500 A\nnapięcie (0,1 - 100) V\nTechnika badawcza polegająca na ładowaniu akumulatorów stałym natężeniem prądu lub stałym napięciem i wyładowaniu stałym natężeniem prądu, stałym napięciem lub stałą mocą Charakterystyki elektryczne:\nmax. dopuszczalne natężenie prądu wyładowania\nodporność cykliczna (trwałość)\nodporność na korozję\npojemność (wyładowanie)\nprąd zwarcia i rezystancja wewnętrzna\nprzydatność do pracy rezerwowej (ładowanie)\nprzyjmowanie ładunku po głębokim wyładowaniu\nwyładowanie wysokim prądem\nzdolność przyjmowania ładunku\nzdolność rozruchowa\nzdolność zachowania ładunku (samowyładowanie)\nzużycie wody (ładowanie) PN-EN 50342-1:2016-01 punkt 6.1 ÷ 6.4, 6.6, 6.7, 6.9 | PN-EN 50342-1:2016-01/A1:2019-01 | IEC 60095-1:2018-11 punkt 9.1 ÷ 9.7 | PN-EN 60254-1:2010 punkt 5.2 ÷ 5.5 | PN-EN 60896-11:2007 punkt 14 ÷ 16,18,19 | PN-EN 60896-21:2007 punkt 6.3, 6.11 ÷ 6.14 | PN-EN 60896-22:2007 | PN-EN 61056-1:2013-05 punkt 7.1 ÷ 7.9 | PN-E-83013:1998 Ogniwa i baterie wtorne kwasowe (olowiowe) Badania elektryczne\nZakres:\nMierzone wielkosci:\nnatezenie pradu\nnapiecie\nnatezenie 0,05 mA - 1500 A\nnapiecie (0,1 - 100) V\nTechnika badawcza polegajaca na ladowaniu akumulatorow stalym natezeniem pradu lub stalym napieciem i wyladowaniu stalym natezeniem pradu, stalym napieciem lub stala moca Charakterystyki elektryczne:\nmax. dopuszczalne natezenie pradu wyladowania\nodpornosc cykliczna (trwalosc)\nodpornosc na korozje\npojemnosc (wyladowanie)\nprad zwarcia i rezystancja wewnetrzna\nprzydatnosc do pracy rezerwowej (ladowanie)\nprzyjmowanie ladunku po glebokim wyladowaniu\nwyladowanie wysokim pradem\nzdolnosc przyjmowania ladunku\nzdolnosc rozruchowa\nzdolnosc zachowania ladunku (samowyladowanie)\nzuzycie wody (ladowanie) PN-EN 50342-1:2016-01 punkt 6.1 ÷ 6.4, 6.6, 6.7, 6.9 | PN-EN 50342-1:2016-01/A1:2019-01 | IEC 60095-1:2018-11 punkt 9.1 ÷ 9.7 | PN-EN 60254-1:2010 punkt 5.2 ÷ 5.5 | PN-EN 60896-11:2007 punkt 14 ÷ 16,18,19 | PN-EN 60896-21:2007 punkt 6.3, 6.11 ÷ 6.14 | PN-EN 60896-22:2007 | PN-EN 61056-1:2013-05 punkt 7.1 ÷ 7.9 | PN-E-83013:1998","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Power Sources Testing Laboratory","methodology_en":"Electrical testing","parameters_en":[{"name":"Measured quantities:"},{"name":"current intensity"},{"name":"voltage"},{"name":"current 0,05 mA - 1500 A"},{"name":"voltage","range":"(0,1 - 100) V"},{"name":"Test technique consisting in charging batteries at constant current or constant voltage and discharging at constant current, constant voltage or constant power Electrical characteristics:"},{"name":"max. permissible discharge current"},{"name":"cyclic resistance (durability)"},{"name":"corrosion resistance"},{"name":"capacity (discharge)"},{"name":"short-circuit current and internal resistance"},{"name":"suitability for standby operation (charging)"},{"name":"charge acceptance after deep discharge"},{"name":"high-current discharge"},{"name":"charge acceptance"},{"name":"starting capability"},{"name":"charge retention capability (self-discharge)"},{"name":"water consumption (loading)"}],"search_en":"Secondary acid (lead-acid) cells and batteries Electrical testing Chemical Power Sources Testing Laboratory Measured quantities: current intensity voltage current 0,05 mA - 1500 A voltage Test technique consisting in charging batteries at constant current or constant voltage and discharging at constant current, constant voltage or constant power Electrical characteristics: max. permissible discharge current cyclic resistance (durability) corrosion resistance capacity (discharge) short-circuit current and internal resistance suitability for standby operation (charging) charge acceptance after deep discharge high-current discharge charge acceptance starting capability charge retention capability (self-discharge) water consumption (loading) PN-EN 50342-1:2016-01 punkt 6.1 ÷ 6.4, 6.6, 6.7, 6.9 | PN-EN 50342-1:2016-01/A1:2019-01 | IEC 60095-1:2018-11 punkt 9.1 ÷ 9.7 | PN-EN 60254-1:2010 punkt 5.2 ÷ 5.5 | PN-EN 60896-11:2007 punkt 14 ÷ 16,18,19 | PN-EN 60896-21:2007 punkt 6.3, 6.11 ÷ 6.14 | PN-EN 60896-22:2007 | PN-EN 61056-1:2013-05 punkt 7.1 ÷ 7.9 | PN-E-83013:1998","test_object_en":"Secondary acid (lead-acid) cells and batteries","lab_section_zh":"化学电源检测实验室","search_zh":"电气检验 化学电源检测实验室 测量量： 电流强度 电压 电压 耐腐蚀性 PN-EN 50342-1:2016-01 punkt 6.1 ÷ 6.4, 6.6, 6.7, 6.9 | PN-EN 50342-1:2016-01/A1:2019-01 | IEC 60095-1:2018-11 punkt 9.1 ÷ 9.7 | PN-EN 60254-1:2010 punkt 5.2 ÷ 5.5 | PN-EN 60896-11:2007 punkt 14 ÷ 16,18,19 | PN-EN 60896-21:2007 punkt 6.3, 6.11 ÷ 6.14 | PN-EN 60896-22:2007 | PN-EN 61056-1:2013-05 punkt 7.1 ÷ 7.9 | PN-E-83013:1998","parameters_zh":[{"name":"测量量："},{"name":"电流强度"},{"name":"电压"},{"name":"natężenie 0,05 mA - 1500 A"},{"name":"电压","range":"(0,1 - 100) V"},{"name":"Technika badawcza polegająca na ładowaniu akumulatorów stałym natężeniem prądu lub stałym napięciem i wyładowaniu stałym natężeniem prądu, stałym napięciem lub stałą mocą Charakterystyki elektryczne:"},{"name":"max. dopuszczalne natężenie prądu wyładowania"},{"name":"odporność cykliczna (trwałość)"},{"name":"耐腐蚀性"},{"name":"pojemność (wyładowanie)"},{"name":"prąd zwarcia i rezystancja wewnętrzna"},{"name":"przydatność do pracy rezerwowej (ładowanie)"},{"name":"przyjmowanie ładunku po głębokim wyładowaniu"},{"name":"wyładowanie wysokim prądem"},{"name":"zdolność przyjmowania ładunku"},{"name":"zdolność rozruchowa"},{"name":"zdolność zachowania ładunku (samowyładowanie)"},{"name":"zużycie wody (ładowanie)"}],"methodology_zh":"电气检验"},{"_id":"6a7d793b0636ba417e41a7b4","lab_id":"69ad52a3de79e566650fb12b","country":"PL","accr_number":"AB 124","accr_body":"PCA","test_object":"Ogniwa i baterie wtórne zasadowe","methodology":"Badania elektryczne","parameters":[{"name":"Mierzone wielkości:"},{"name":"natężenie prądu"},{"name":"napięcie"},{"name":"natężenie 2 mA - 1500 A"},{"name":"napięcie","range":"(0,1 - 800) V"},{"name":"Technika badawcza polegająca na ładowaniu ogniw i baterii stałym natężeniem prądu lub stałym napięciem i wyładowaniu stałym natężeniem prądu, stałym napięciem lub stałą mocą Charakterystyki elektryczne:"},{"name":"działanie urządzenia zabezpieczającego"},{"name":"ładowanie stałym napięciem"},{"name":"odporność cykliczna (trwałość)"},{"name":"prąd deklarowanej mocy"},{"name":"przeładowanie"},{"name":"przyjmowanie ładunku przy stałej wartości napięcia"},{"name":"przyjmowanie ładunku przy stałej wartość natężenia prądu"},{"name":"rezystancja wewnętrzna"},{"name":"stabilność ładowania"},{"name":"wyładowanie"},{"name":"zdolność rozruchowa"},{"name":"zdolność zachowania ładunku (samowyładowanie)"}],"technique":null,"techniques":[],"computed":[],"activity":"Badania elektryczne\nZakres:\nMierzone wielkości:\nnatężenie prądu\nnapięcie\nnatężenie 2 mA - 1500 A\nnapięcie (0,1 - 800) V\nTechnika badawcza polegająca na ładowaniu ogniw i baterii stałym natężeniem prądu lub stałym napięciem i wyładowaniu stałym natężeniem prądu, stałym napięciem lub stałą mocą Charakterystyki elektryczne:\ndziałanie urządzenia zabezpieczającego\nładowanie stałym napięciem\nodporność cykliczna (trwałość)\nprąd deklarowanej mocy\nprzeładowanie\nprzyjmowanie ładunku przy stałej wartości napięcia\nprzyjmowanie ładunku przy stałej wartość natężenia prądu\nrezystancja wewnętrzna\nstabilność ładowania\nwyładowanie\nzdolność rozruchowa\nzdolność zachowania ładunku (samowyładowanie)","reference":"PN-EN 2570:2001 punkt 5.3.7, 5.4.1, 5.4.4, 5.4.5 | PN-EN 60622:2007 punkt 4 | PN-EN 60623:2017-07 punkt 7 | PN-EN 60952-1:2014-02 punkt 5 | PN-EN 61951-1:2017-10 punkt 7 | PN-EN 61951-1:2017-10/A1:2023-11 | PN-EN 61951-2:2017-10 punkt 7 | PN-EN 61951-2:2017-10/A1:2023-08 | PN-EN 61960-3:2017-08 punkt 7 | PN-EN 62133-1:2017-08 punkt 7.2.1, 7.3.8 , 7.3.9 | PN-EN 62133-2:2017-08 punkt 7.2.1, 7.3.6, 7.3.7 | PN-EN 62133-2:2017-08/A1:2022-04 | PN-EN 62259:2004 punkt 7.1, 7.2, 7.3, 7.4, 7.5, 7.7, 7.10 | PN-EN IEC 62281:2019-08 punkt 6.5.1 (test T.7) punkt 6.5.2 (test T.8) | PN-EN IEC 62281:2019-08/A1:2021-11 | PN-EN IEC 62281:2019-08/A2:2023-12 | PN-EN IEC 62619:2023-02 punkt 7.2.6, 8.2.2, 8.2.3 | PN-EN 62620:2015-05 punkt 6.3.1 6.4, 6.6.1, 6.6.2 | PN-EN 62620:2015-05/A1:2024-02 | PN-EN 62660-2:2019-04 punkt 6.4.2, 6.4.3 | PN-EN IEC 63056:2020-12 | PN-EN IEC 63056:2020-12/AC:2021-09 punkt 7.5, 7.6, 7.8","norm_bases":["PN-EN 2570:2001 punkt 5.3.7, 5.4.1, 5.4.4, 5.4.5","PN-EN 60622:2007 punkt 4","PN-EN 60623:2017-07 punkt 7","PN-EN 60952-1:2014-02 punkt 5","PN-EN 61951-1:2017-10 punkt 7","PN-EN 61951-1:2017-10/A1:2023-11","PN-EN 61951-2:2017-10 punkt 7","PN-EN 61951-2:2017-10/A1:2023-08","PN-EN 61960-3:2017-08 punkt 7","PN-EN 62133-1:2017-08 punkt 7.2.1, 7.3.8 , 7.3.9","PN-EN 62133-2:2017-08 punkt 7.2.1, 7.3.6, 7.3.7","PN-EN 62133-2:2017-08/A1:2022-04","PN-EN 62259:2004 punkt 7.1, 7.2, 7.3, 7.4, 7.5, 7.7, 7.10","PN-EN IEC 62281:2019-08 punkt 6.5.1 (test T.7) punkt 6.5.2 (test T.8)","PN-EN IEC 62281:2019-08/A1:2021-11","PN-EN IEC 62281:2019-08/A2:2023-12","PN-EN IEC 62619:2023-02 punkt 7.2.6, 8.2.2, 8.2.3","PN-EN 62620:2015-05 punkt 6.3.1 6.4, 6.6.1, 6.6.2","PN-EN 62620:2015-05/A1:2024-02","PN-EN 62660-2:2019-04 punkt 6.4.2, 6.4.3","PN-EN IEC 63056:2020-12","PN-EN IEC 63056:2020-12/AC:2021-09 punkt 7.5, 7.6, 7.8"],"lab_section":"Laboratorium Badań Chemicznych Źródeł Prądu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ogniwa i baterie wtórne zasadowe Badania elektryczne\nZakres:\nMierzone wielkości:\nnatężenie prądu\nnapięcie\nnatężenie 2 mA - 1500 A\nnapięcie (0,1 - 800) V\nTechnika badawcza polegająca na ładowaniu ogniw i baterii stałym natężeniem prądu lub stałym napięciem i wyładowaniu stałym natężeniem prądu, stałym napięciem lub stałą mocą Charakterystyki elektryczne:\ndziałanie urządzenia zabezpieczającego\nładowanie stałym napięciem\nodporność cykliczna (trwałość)\nprąd deklarowanej mocy\nprzeładowanie\nprzyjmowanie ładunku przy stałej wartości napięcia\nprzyjmowanie ładunku przy stałej wartość natężenia prądu\nrezystancja wewnętrzna\nstabilność ładowania\nwyładowanie\nzdolność rozruchowa\nzdolność zachowania ładunku (samowyładowanie) PN-EN 2570:2001 punkt 5.3.7, 5.4.1, 5.4.4, 5.4.5 | PN-EN 60622:2007 punkt 4 | PN-EN 60623:2017-07 punkt 7 | PN-EN 60952-1:2014-02 punkt 5 | PN-EN 61951-1:2017-10 punkt 7 | PN-EN 61951-1:2017-10/A1:2023-11 | PN-EN 61951-2:2017-10 punkt 7 | PN-EN 61951-2:2017-10/A1:2023-08 | PN-EN 61960-3:2017-08 punkt 7 | PN-EN 62133-1:2017-08 punkt 7.2.1, 7.3.8 , 7.3.9 | PN-EN 62133-2:2017-08 punkt 7.2.1, 7.3.6, 7.3.7 | PN-EN 62133-2:2017-08/A1:2022-04 | PN-EN 62259:2004 punkt 7.1, 7.2, 7.3, 7.4, 7.5, 7.7, 7.10 | PN-EN IEC 62281:2019-08 punkt 6.5.1 (test T.7) punkt 6.5.2 (test T.8) | PN-EN IEC 62281:2019-08/A1:2021-11 | PN-EN IEC 62281:2019-08/A2:2023-12 | PN-EN IEC 62619:2023-02 punkt 7.2.6, 8.2.2, 8.2.3 | PN-EN 62620:2015-05 punkt 6.3.1 6.4, 6.6.1, 6.6.2 | PN-EN 62620:2015-05/A1:2024-02 | PN-EN 62660-2:2019-04 punkt 6.4.2, 6.4.3 | PN-EN IEC 63056:2020-12 | PN-EN IEC 63056:2020-12/AC:2021-09 punkt 7.5, 7.6, 7.8 Ogniwa i baterie wtorne zasadowe Badania elektryczne\nZakres:\nMierzone wielkosci:\nnatezenie pradu\nnapiecie\nnatezenie 2 mA - 1500 A\nnapiecie (0,1 - 800) V\nTechnika badawcza polegajaca na ladowaniu ogniw i baterii stalym natezeniem pradu lub stalym napieciem i wyladowaniu stalym natezeniem pradu, stalym napieciem lub stala moca Charakterystyki elektryczne:\ndzialanie urzadzenia zabezpieczajacego\nladowanie stalym napieciem\nodpornosc cykliczna (trwalosc)\nprad deklarowanej mocy\nprzeladowanie\nprzyjmowanie ladunku przy stalej wartosci napiecia\nprzyjmowanie ladunku przy stalej wartosc natezenia pradu\nrezystancja wewnetrzna\nstabilnosc ladowania\nwyladowanie\nzdolnosc rozruchowa\nzdolnosc zachowania ladunku (samowyladowanie) PN-EN 2570:2001 punkt 5.3.7, 5.4.1, 5.4.4, 5.4.5 | PN-EN 60622:2007 punkt 4 | PN-EN 60623:2017-07 punkt 7 | PN-EN 60952-1:2014-02 punkt 5 | PN-EN 61951-1:2017-10 punkt 7 | PN-EN 61951-1:2017-10/A1:2023-11 | PN-EN 61951-2:2017-10 punkt 7 | PN-EN 61951-2:2017-10/A1:2023-08 | PN-EN 61960-3:2017-08 punkt 7 | PN-EN 62133-1:2017-08 punkt 7.2.1, 7.3.8 , 7.3.9 | PN-EN 62133-2:2017-08 punkt 7.2.1, 7.3.6, 7.3.7 | PN-EN 62133-2:2017-08/A1:2022-04 | PN-EN 62259:2004 punkt 7.1, 7.2, 7.3, 7.4, 7.5, 7.7, 7.10 | PN-EN IEC 62281:2019-08 punkt 6.5.1 (test T.7) punkt 6.5.2 (test T.8) | PN-EN IEC 62281:2019-08/A1:2021-11 | PN-EN IEC 62281:2019-08/A2:2023-12 | PN-EN IEC 62619:2023-02 punkt 7.2.6, 8.2.2, 8.2.3 | PN-EN 62620:2015-05 punkt 6.3.1 6.4, 6.6.1, 6.6.2 | PN-EN 62620:2015-05/A1:2024-02 | PN-EN 62660-2:2019-04 punkt 6.4.2, 6.4.3 | PN-EN IEC 63056:2020-12 | PN-EN IEC 63056:2020-12/AC:2021-09 punkt 7.5, 7.6, 7.8","categories":["other"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Power Sources Testing Laboratory","methodology_en":"Electrical testing","parameters_en":[{"name":"Measured quantities:"},{"name":"current intensity"},{"name":"voltage"},{"name":"current 2 mA - 1500 A"},{"name":"voltage","range":"(0,1 - 800) V"},{"name":"Test technique consisting in charging cells and batteries at constant current or constant voltage and discharging at constant current, constant voltage or constant power Electrical characteristics:"},{"name":"operation of the safety device"},{"name":"constant voltage charging"},{"name":"cyclic resistance (durability)"},{"name":"current at declared power"},{"name":"overcharging"},{"name":"charge acceptance at constant voltage"},{"name":"charge acceptance at constant current"},{"name":"internal resistance"},{"name":"charging stability"},{"name":"discharge"},{"name":"starting capability"},{"name":"charge retention capability (self-discharge)"}],"search_en":"Secondary alkaline cells and batteries Electrical testing Chemical Power Sources Testing Laboratory Measured quantities: current intensity voltage current 2 mA - 1500 A voltage Test technique consisting in charging cells and batteries at constant current or constant voltage and discharging at constant current, constant voltage or constant power Electrical characteristics: operation of the safety device constant voltage charging cyclic resistance (durability) current at declared power overcharging charge acceptance at constant voltage charge acceptance at constant current internal resistance charging stability discharge starting capability charge retention capability (self-discharge) PN-EN 2570:2001 punkt 5.3.7, 5.4.1, 5.4.4, 5.4.5 | PN-EN 60622:2007 punkt 4 | PN-EN 60623:2017-07 punkt 7 | PN-EN 60952-1:2014-02 punkt 5 | PN-EN 61951-1:2017-10 punkt 7 | PN-EN 61951-1:2017-10/A1:2023-11 | PN-EN 61951-2:2017-10 punkt 7 | PN-EN 61951-2:2017-10/A1:2023-08 | PN-EN 61960-3:2017-08 punkt 7 | PN-EN 62133-1:2017-08 punkt 7.2.1, 7.3.8 , 7.3.9 | PN-EN 62133-2:2017-08 punkt 7.2.1, 7.3.6, 7.3.7 | PN-EN 62133-2:2017-08/A1:2022-04 | PN-EN 62259:2004 punkt 7.1, 7.2, 7.3, 7.4, 7.5, 7.7, 7.10 | PN-EN IEC 62281:2019-08 punkt 6.5.1 (test T.7) punkt 6.5.2 (test T.8) | PN-EN IEC 62281:2019-08/A1:2021-11 | PN-EN IEC 62281:2019-08/A2:2023-12 | PN-EN IEC 62619:2023-02 punkt 7.2.6, 8.2.2, 8.2.3 | PN-EN 62620:2015-05 punkt 6.3.1 6.4, 6.6.1, 6.6.2 | PN-EN 62620:2015-05/A1:2024-02 | PN-EN 62660-2:2019-04 punkt 6.4.2, 6.4.3 | PN-EN IEC 63056:2020-12 | PN-EN IEC 63056:2020-12/AC:2021-09 punkt 7.5, 7.6, 7.8","test_object_en":"Secondary alkaline cells and batteries","lab_section_zh":"化学电源检测实验室","search_zh":"电气检验 化学电源检测实验室 测量量： 电流强度 电压 电压 PN-EN 2570:2001 punkt 5.3.7, 5.4.1, 5.4.4, 5.4.5 | PN-EN 60622:2007 punkt 4 | PN-EN 60623:2017-07 punkt 7 | PN-EN 60952-1:2014-02 punkt 5 | PN-EN 61951-1:2017-10 punkt 7 | PN-EN 61951-1:2017-10/A1:2023-11 | PN-EN 61951-2:2017-10 punkt 7 | PN-EN 61951-2:2017-10/A1:2023-08 | PN-EN 61960-3:2017-08 punkt 7 | PN-EN 62133-1:2017-08 punkt 7.2.1, 7.3.8 , 7.3.9 | PN-EN 62133-2:2017-08 punkt 7.2.1, 7.3.6, 7.3.7 | PN-EN 62133-2:2017-08/A1:2022-04 | PN-EN 62259:2004 punkt 7.1, 7.2, 7.3, 7.4, 7.5, 7.7, 7.10 | PN-EN IEC 62281:2019-08 punkt 6.5.1 (test T.7) punkt 6.5.2 (test T.8) | PN-EN IEC 62281:2019-08/A1:2021-11 | PN-EN IEC 62281:2019-08/A2:2023-12 | PN-EN IEC 62619:2023-02 punkt 7.2.6, 8.2.2, 8.2.3 | PN-EN 62620:2015-05 punkt 6.3.1 6.4, 6.6.1, 6.6.2 | PN-EN 62620:2015-05/A1:2024-02 | PN-EN 62660-2:2019-04 punkt 6.4.2, 6.4.3 | PN-EN IEC 63056:2020-12 | PN-EN IEC 63056:2020-12/AC:2021-09 punkt 7.5, 7.6, 7.8","parameters_zh":[{"name":"测量量："},{"name":"电流强度"},{"name":"电压"},{"name":"natężenie 2 mA - 1500 A"},{"name":"电压","range":"(0,1 - 800) V"},{"name":"Technika badawcza polegająca na ładowaniu ogniw i baterii stałym natężeniem prądu lub stałym napięciem i wyładowaniu stałym natężeniem prądu, stałym napięciem lub stałą mocą Charakterystyki elektryczne:"},{"name":"działanie urządzenia zabezpieczającego"},{"name":"ładowanie stałym napięciem"},{"name":"odporność cykliczna (trwałość)"},{"name":"prąd deklarowanej mocy"},{"name":"przeładowanie"},{"name":"przyjmowanie ładunku przy stałej wartości napięcia"},{"name":"przyjmowanie ładunku przy stałej wartość natężenia prądu"},{"name":"rezystancja wewnętrzna"},{"name":"stabilność ładowania"},{"name":"wyładowanie"},{"name":"zdolność rozruchowa"},{"name":"zdolność zachowania ładunku (samowyładowanie)"}],"methodology_zh":"电气检验"},{"_id":"6a7d793b0636ba417e41a7b5","lab_id":"69ad52a3de79e566650fb12b","country":"PL","accr_number":"AB 124","accr_body":"PCA","test_object":"Ogniwa i baterie pierwotne, Ogniwa i baterie wtórne kwasowe, Ogniwa i baterie wtórne zasadowe","methodology":"Badania klimatyczne / termiczne Odporność na:","parameters":[{"name":"cykliczne zmiany temperatury"},{"name":"obniżoną temperaturę"},{"name":"podwyższoną temperaturę"},{"name":"udar termiczny"},{"name":"Zakres","range":"(-70 do + 180)oC"}],"technique":"Metoda badawcza: poddanie badanych obiektów działaniu ww. warunków w komorze klimatycznej","techniques":["Metoda badawcza: poddanie badanych obiektów działaniu ww. warunków w komorze klimatycznej"],"computed":[],"activity":"Badania klimatyczne / termiczne Odporność na:\nZakres:\ncykliczne zmiany temperatury\nobniżoną temperaturę\npodwyższoną temperaturę\nudar termiczny\nZakres (-70 do + 180)oC\nMetoda badawcza: poddanie badanych obiektów działaniu ww. warunków w komorze klimatycznej","reference":"PN-EN 2570:2001 punkt 5.3.1 | PN-EN IEC 60086-3:2022-01 punkt 7.3.2 | PN-EN IEC 60086-3:2022-01/AC:2023-10 | PN-EN IEC 60086-4:2026-02 punkt 6.4.2, 6.5.8 | PN-EN IEC 60086-5:2022-06 punkt 6.3.2.4 | PN-EN IEC 60086-5:2022-06/AC:2022-08 | PN-EN 60068-2-1:2009 | PN-EN 60068-2-2:2009 | PN-EN IEC 60068-2-14:2024-04 | PN-EN 62133-1:2017-08 punkt 7.2.3, 7.2.4, 7.3.5 | PN-EN 62133-2:2017-08 punkt 7.2.2, 7.3.4 | PN-EN 62133-2:2017-08/A1:2022-04 | PN-EN IEC 62281:2019-08 punkt 6.4.2 (test T.2) | PN-EN IEC 62281:2019-08/A1:2021-11 | PN-EN IEC 62281:2019-08/A2:2023-12 | PN-EN IEC 62619:2023-02 punkt 7.2.4, 8.2.4 | PN-EN IEC 62660-2:2019-04 punkt 6.3.1","norm_bases":["PN-EN 2570:2001 punkt 5.3.1","PN-EN IEC 60086-3:2022-01 punkt 7.3.2","PN-EN IEC 60086-3:2022-01/AC:2023-10","PN-EN IEC 60086-4:2026-02 punkt 6.4.2, 6.5.8","PN-EN IEC 60086-5:2022-06 punkt 6.3.2.4","PN-EN IEC 60086-5:2022-06/AC:2022-08","PN-EN 60068-2-1:2009","PN-EN 60068-2-2:2009","PN-EN IEC 60068-2-14:2024-04","PN-EN 62133-1:2017-08 punkt 7.2.3, 7.2.4, 7.3.5","PN-EN 62133-2:2017-08 punkt 7.2.2, 7.3.4","PN-EN 62133-2:2017-08/A1:2022-04","PN-EN IEC 62281:2019-08 punkt 6.4.2 (test T.2)","PN-EN IEC 62281:2019-08/A1:2021-11","PN-EN IEC 62281:2019-08/A2:2023-12","PN-EN IEC 62619:2023-02 punkt 7.2.4, 8.2.4","PN-EN IEC 62660-2:2019-04 punkt 6.3.1"],"lab_section":"Laboratorium Badań Chemicznych Źródeł Prądu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ogniwa i baterie pierwotne, Ogniwa i baterie wtórne kwasowe, Ogniwa i baterie wtórne zasadowe Badania klimatyczne / termiczne Odporność na:\nZakres:\ncykliczne zmiany temperatury\nobniżoną temperaturę\npodwyższoną temperaturę\nudar termiczny\nZakres (-70 do + 180)oC\nMetoda badawcza: poddanie badanych obiektów działaniu ww. warunków w komorze klimatycznej PN-EN 2570:2001 punkt 5.3.1 | PN-EN IEC 60086-3:2022-01 punkt 7.3.2 | PN-EN IEC 60086-3:2022-01/AC:2023-10 | PN-EN IEC 60086-4:2026-02 punkt 6.4.2, 6.5.8 | PN-EN IEC 60086-5:2022-06 punkt 6.3.2.4 | PN-EN IEC 60086-5:2022-06/AC:2022-08 | PN-EN 60068-2-1:2009 | PN-EN 60068-2-2:2009 | PN-EN IEC 60068-2-14:2024-04 | PN-EN 62133-1:2017-08 punkt 7.2.3, 7.2.4, 7.3.5 | PN-EN 62133-2:2017-08 punkt 7.2.2, 7.3.4 | PN-EN 62133-2:2017-08/A1:2022-04 | PN-EN IEC 62281:2019-08 punkt 6.4.2 (test T.2) | PN-EN IEC 62281:2019-08/A1:2021-11 | PN-EN IEC 62281:2019-08/A2:2023-12 | PN-EN IEC 62619:2023-02 punkt 7.2.4, 8.2.4 | PN-EN IEC 62660-2:2019-04 punkt 6.3.1 Ogniwa i baterie pierwotne, Ogniwa i baterie wtorne kwasowe, Ogniwa i baterie wtorne zasadowe Badania klimatyczne / termiczne Odpornosc na:\nZakres:\ncykliczne zmiany temperatury\nobnizona temperature\npodwyzszona temperature\nudar termiczny\nZakres (-70 do + 180)oC\nMetoda badawcza: poddanie badanych obiektow dzialaniu ww. warunkow w komorze klimatycznej PN-EN 2570:2001 punkt 5.3.1 | PN-EN IEC 60086-3:2022-01 punkt 7.3.2 | PN-EN IEC 60086-3:2022-01/AC:2023-10 | PN-EN IEC 60086-4:2026-02 punkt 6.4.2, 6.5.8 | PN-EN IEC 60086-5:2022-06 punkt 6.3.2.4 | PN-EN IEC 60086-5:2022-06/AC:2022-08 | PN-EN 60068-2-1:2009 | PN-EN 60068-2-2:2009 | PN-EN IEC 60068-2-14:2024-04 | PN-EN 62133-1:2017-08 punkt 7.2.3, 7.2.4, 7.3.5 | PN-EN 62133-2:2017-08 punkt 7.2.2, 7.3.4 | PN-EN 62133-2:2017-08/A1:2022-04 | PN-EN IEC 62281:2019-08 punkt 6.4.2 (test T.2) | PN-EN IEC 62281:2019-08/A1:2021-11 | PN-EN IEC 62281:2019-08/A2:2023-12 | PN-EN IEC 62619:2023-02 punkt 7.2.4, 8.2.4 | PN-EN IEC 62660-2:2019-04 punkt 6.3.1","categories":["other"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Power Sources Testing Laboratory","methodology_en":"Climatic / thermal testing Resistance to:","parameters_en":[{"name":"cyclic temperature changes"},{"name":"reduced temperature"},{"name":"elevated temperature"},{"name":"thermal shock"},{"name":"Range","range":"(-70 do + 180)oC"}],"search_en":"Primary cells and batteries, Secondary acid cells and batteries, Secondary alkaline cells and batteries Climatic / thermal testing Resistance to: Test method: exposure of the tested objects to the above conditions in a climatic chamber Chemical Power Sources Testing Laboratory cyclic temperature changes reduced temperature elevated temperature thermal shock Range PN-EN 2570:2001 punkt 5.3.1 | PN-EN IEC 60086-3:2022-01 punkt 7.3.2 | PN-EN IEC 60086-3:2022-01/AC:2023-10 | PN-EN IEC 60086-4:2026-02 punkt 6.4.2, 6.5.8 | PN-EN IEC 60086-5:2022-06 punkt 6.3.2.4 | PN-EN IEC 60086-5:2022-06/AC:2022-08 | PN-EN 60068-2-1:2009 | PN-EN 60068-2-2:2009 | PN-EN IEC 60068-2-14:2024-04 | PN-EN 62133-1:2017-08 punkt 7.2.3, 7.2.4, 7.3.5 | PN-EN 62133-2:2017-08 punkt 7.2.2, 7.3.4 | PN-EN 62133-2:2017-08/A1:2022-04 | PN-EN IEC 62281:2019-08 punkt 6.4.2 (test T.2) | PN-EN IEC 62281:2019-08/A1:2021-11 | PN-EN IEC 62281:2019-08/A2:2023-12 | PN-EN IEC 62619:2023-02 punkt 7.2.4, 8.2.4 | PN-EN IEC 62660-2:2019-04 punkt 6.3.1","technique_en":"Test method: exposure of the tested objects to the above conditions in a climatic chamber","test_object_en":"Primary cells and batteries, Secondary acid cells and batteries, Secondary alkaline cells and batteries","parameters_zh":[{"name":"cykliczne zmiany temperatury"},{"name":"obniżoną temperaturę"},{"name":"podwyższoną temperaturę"},{"name":"udar termiczny"},{"name":"范围","range":"(-70 do + 180)oC"}],"search_zh":"原电池与电池组、酸性蓄电池与蓄电池组、碱性蓄电池与蓄电池组 化学电源检测实验室 范围 PN-EN 2570:2001 punkt 5.3.1 | PN-EN IEC 60086-3:2022-01 punkt 7.3.2 | PN-EN IEC 60086-3:2022-01/AC:2023-10 | PN-EN IEC 60086-4:2026-02 punkt 6.4.2, 6.5.8 | PN-EN IEC 60086-5:2022-06 punkt 6.3.2.4 | PN-EN IEC 60086-5:2022-06/AC:2022-08 | PN-EN 60068-2-1:2009 | PN-EN 60068-2-2:2009 | PN-EN IEC 60068-2-14:2024-04 | PN-EN 62133-1:2017-08 punkt 7.2.3, 7.2.4, 7.3.5 | PN-EN 62133-2:2017-08 punkt 7.2.2, 7.3.4 | PN-EN 62133-2:2017-08/A1:2022-04 | PN-EN IEC 62281:2019-08 punkt 6.4.2 (test T.2) | PN-EN IEC 62281:2019-08/A1:2021-11 | PN-EN IEC 62281:2019-08/A2:2023-12 | PN-EN IEC 62619:2023-02 punkt 7.2.4, 8.2.4 | PN-EN IEC 62660-2:2019-04 punkt 6.3.1","lab_section_zh":"化学电源检测实验室","test_object_zh":"原电池与电池组、酸性蓄电池与蓄电池组、碱性蓄电池与蓄电池组"},{"_id":"6a7d793b0636ba417e41a7b6","lab_id":"69ad52a3de79e566650fb12b","country":"PL","accr_number":"AB 124","accr_body":"PCA","test_object":"Ogniwa i baterie pierwotne, Ogniwa i baterie wtórne kwasowe, Ogniwa i baterie wtórne zasadowe","methodology":"Badania klimatyczne / wilgotność Odporność na:","parameters":[{"name":"zwiększoną wilgotność"},{"name":"Zakres","range":"(20 - 98)% wilgotności"}],"technique":"Metoda badawcza: poddanie badanych obiektów działaniu ww. warunków w komorze klimatycznej","techniques":["Metoda badawcza: poddanie badanych obiektów działaniu ww. warunków w komorze klimatycznej"],"computed":[],"activity":"Badania klimatyczne / wilgotność Odporność na:\nZakres:\nzwiększoną wilgotność\nZakres (20 - 98)% wilgotności\nMetoda badawcza: poddanie badanych obiektów działaniu ww. warunków w komorze klimatycznej","reference":"PN-EN 2570:2001 punkt 5.3.4","norm_bases":["PN-EN 2570:2001 punkt 5.3.4"],"lab_section":"Laboratorium Badań Chemicznych Źródeł Prądu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ogniwa i baterie pierwotne, Ogniwa i baterie wtórne kwasowe, Ogniwa i baterie wtórne zasadowe Badania klimatyczne / wilgotność Odporność na:\nZakres:\nzwiększoną wilgotność\nZakres (20 - 98)% wilgotności\nMetoda badawcza: poddanie badanych obiektów działaniu ww. warunków w komorze klimatycznej PN-EN 2570:2001 punkt 5.3.4 Ogniwa i baterie pierwotne, Ogniwa i baterie wtorne kwasowe, Ogniwa i baterie wtorne zasadowe Badania klimatyczne / wilgotnosc Odpornosc na:\nZakres:\nzwiekszona wilgotnosc\nZakres (20 - 98)% wilgotnosci\nMetoda badawcza: poddanie badanych obiektow dzialaniu ww. warunkow w komorze klimatycznej PN-EN 2570:2001 punkt 5.3.4","categories":["other"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Power Sources Testing Laboratory","methodology_en":"Climatic testing / humidity Resistance to:","parameters_en":[{"name":"increased humidity"},{"name":"Range","range":"(20 - 98)% wilgotności"}],"search_en":"Primary cells and batteries, Secondary acid cells and batteries, Secondary alkaline cells and batteries Climatic testing / humidity Resistance to: Test method: exposure of the tested objects to the above conditions in a climatic chamber Chemical Power Sources Testing Laboratory increased humidity Range PN-EN 2570:2001 punkt 5.3.4","technique_en":"Test method: exposure of the tested objects to the above conditions in a climatic chamber","test_object_en":"Primary cells and batteries, Secondary acid cells and batteries, Secondary alkaline cells and batteries","parameters_zh":[{"name":"zwiększoną wilgotność"},{"name":"范围","range":"(20 - 98)% wilgotności"}],"search_zh":"原电池与电池组、酸性蓄电池与蓄电池组、碱性蓄电池与蓄电池组 化学电源检测实验室 范围 PN-EN 2570:2001 punkt 5.3.4","lab_section_zh":"化学电源检测实验室","test_object_zh":"原电池与电池组、酸性蓄电池与蓄电池组、碱性蓄电池与蓄电池组"},{"_id":"6a7d793b0636ba417e41a7b7","lab_id":"69ad52a3de79e566650fb12b","country":"PL","accr_number":"AB 124","accr_body":"PCA","test_object":"Ogniwa i baterie pierwotne, Ogniwa i baterie wtórne kwasowe, Ogniwa i baterie wtórne zasadowe","methodology":"Badania klimatyczne / ciśnienie Odporność na:","parameters":[{"name":"obniżone ciśnienie"},{"name":"Zakres","range":"(2 - 20) kPa"}],"technique":"Metoda badawcza: poddanie badanych obiektów działaniu ww. warunków w komorze próżniowej","techniques":["Metoda badawcza: poddanie badanych obiektów działaniu ww. warunków w komorze próżniowej"],"computed":[],"activity":"Badania klimatyczne / ciśnienie Odporność na:\nZakres:\nobniżone ciśnienie\nZakres (2 - 20) kPa\nMetoda badawcza: poddanie badanych obiektów działaniu ww. warunków w komorze próżniowej","reference":"PN-EN 2570:2001 punkt 5.3.2 | PN-EN IEC 60086-4:2026-02 punkt 6.4.1 | PN-EN 62133-1:2017-08 punkt 7.3.7 | PN-EN IEC 62281:2019-08 punkt 6.4.1 (Test T.1) | PN-EN IEC 62281:2019-08/A1:2021-11 | PN-EN IEC 62281:2019-08/A2:2023-12","norm_bases":["PN-EN 2570:2001 punkt 5.3.2","PN-EN IEC 60086-4:2026-02 punkt 6.4.1","PN-EN 62133-1:2017-08 punkt 7.3.7","PN-EN IEC 62281:2019-08 punkt 6.4.1 (Test T.1)","PN-EN IEC 62281:2019-08/A1:2021-11","PN-EN IEC 62281:2019-08/A2:2023-12"],"lab_section":"Laboratorium Badań Chemicznych Źródeł Prądu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ogniwa i baterie pierwotne, Ogniwa i baterie wtórne kwasowe, Ogniwa i baterie wtórne zasadowe Badania klimatyczne / ciśnienie Odporność na:\nZakres:\nobniżone ciśnienie\nZakres (2 - 20) kPa\nMetoda badawcza: poddanie badanych obiektów działaniu ww. warunków w komorze próżniowej PN-EN 2570:2001 punkt 5.3.2 | PN-EN IEC 60086-4:2026-02 punkt 6.4.1 | PN-EN 62133-1:2017-08 punkt 7.3.7 | PN-EN IEC 62281:2019-08 punkt 6.4.1 (Test T.1) | PN-EN IEC 62281:2019-08/A1:2021-11 | PN-EN IEC 62281:2019-08/A2:2023-12 Ogniwa i baterie pierwotne, Ogniwa i baterie wtorne kwasowe, Ogniwa i baterie wtorne zasadowe Badania klimatyczne / cisnienie Odpornosc na:\nZakres:\nobnizone cisnienie\nZakres (2 - 20) kPa\nMetoda badawcza: poddanie badanych obiektow dzialaniu ww. warunkow w komorze prozniowej PN-EN 2570:2001 punkt 5.3.2 | PN-EN IEC 60086-4:2026-02 punkt 6.4.1 | PN-EN 62133-1:2017-08 punkt 7.3.7 | PN-EN IEC 62281:2019-08 punkt 6.4.1 (Test T.1) | PN-EN IEC 62281:2019-08/A1:2021-11 | PN-EN IEC 62281:2019-08/A2:2023-12","categories":["other"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Power Sources Testing Laboratory","methodology_en":"Climatic testing / pressure Resistance to:","parameters_en":[{"name":"reduced pressure"},{"name":"Range","range":"(2 - 20) kPa"}],"search_en":"Primary cells and batteries, Secondary acid cells and batteries, Secondary alkaline cells and batteries Climatic testing / pressure Resistance to: Test method: exposure of the tested objects to the above conditions in a vacuum chamber Chemical Power Sources Testing Laboratory reduced pressure Range PN-EN 2570:2001 punkt 5.3.2 | PN-EN IEC 60086-4:2026-02 punkt 6.4.1 | PN-EN 62133-1:2017-08 punkt 7.3.7 | PN-EN IEC 62281:2019-08 punkt 6.4.1 (Test T.1) | PN-EN IEC 62281:2019-08/A1:2021-11 | PN-EN IEC 62281:2019-08/A2:2023-12","technique_en":"Test method: exposure of the tested objects to the above conditions in a vacuum chamber","test_object_en":"Primary cells and batteries, Secondary acid cells and batteries, Secondary alkaline cells and batteries","parameters_zh":[{"name":"obniżone ciśnienie"},{"name":"范围","range":"(2 - 20) kPa"}],"search_zh":"原电池与电池组、酸性蓄电池与蓄电池组、碱性蓄电池与蓄电池组 化学电源检测实验室 范围 PN-EN 2570:2001 punkt 5.3.2 | PN-EN IEC 60086-4:2026-02 punkt 6.4.1 | PN-EN 62133-1:2017-08 punkt 7.3.7 | PN-EN IEC 62281:2019-08 punkt 6.4.1 (Test T.1) | PN-EN IEC 62281:2019-08/A1:2021-11 | PN-EN IEC 62281:2019-08/A2:2023-12","lab_section_zh":"化学电源检测实验室","test_object_zh":"原电池与电池组、酸性蓄电池与蓄电池组、碱性蓄电池与蓄电池组"},{"_id":"6a7d793b0636ba417e41a7b8","lab_id":"69ad52a3de79e566650fb12b","country":"PL","accr_number":"AB 124","accr_body":"PCA","test_object":"Ogniwa i baterie wtórne zasadowe","methodology":"Wymiary","parameters":[{"name":"Zakres","range":"(0,5 - 630) mm"}],"technique":null,"techniques":[],"computed":[],"activity":"Wymiary\nZakres (0,5 - 630) mm","reference":"PN-EN 2570:2001 punkt 5.2.1.3 | PN-EN 60622:2007 punkt 3 | PN-EN 60623:2017-07 punkt 6 | PN-EN 61951-1:2017-10 punkt 6 | PN-EN 61951-1 :2017-10/A1:2023-11 | PN-EN 61951-2 :2017-10 punkt 6 | PN-EN 61951-2 :2017-10/A1:2023-08","norm_bases":["PN-EN 2570:2001 punkt 5.2.1.3","PN-EN 60622:2007 punkt 3","PN-EN 60623:2017-07 punkt 6","PN-EN 61951-1:2017-10 punkt 6","PN-EN 61951-1 :2017-10/A1:2023-11","PN-EN 61951-2 :2017-10 punkt 6","PN-EN 61951-2 :2017-10/A1:2023-08"],"lab_section":"Laboratorium Badań Chemicznych Źródeł Prądu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ogniwa i baterie wtórne zasadowe Wymiary\nZakres (0,5 - 630) mm PN-EN 2570:2001 punkt 5.2.1.3 | PN-EN 60622:2007 punkt 3 | PN-EN 60623:2017-07 punkt 6 | PN-EN 61951-1:2017-10 punkt 6 | PN-EN 61951-1 :2017-10/A1:2023-11 | PN-EN 61951-2 :2017-10 punkt 6 | PN-EN 61951-2 :2017-10/A1:2023-08 Ogniwa i baterie wtorne zasadowe Wymiary\nZakres (0,5 - 630) mm PN-EN 2570:2001 punkt 5.2.1.3 | PN-EN 60622:2007 punkt 3 | PN-EN 60623:2017-07 punkt 6 | PN-EN 61951-1:2017-10 punkt 6 | PN-EN 61951-1 :2017-10/A1:2023-11 | PN-EN 61951-2 :2017-10 punkt 6 | PN-EN 61951-2 :2017-10/A1:2023-08","categories":["other"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Power Sources Testing Laboratory","methodology_en":"Dimensions","parameters_en":[{"name":"Range","range":"(0,5 - 630) mm"}],"search_en":"Secondary alkaline cells and batteries Dimensions Chemical Power Sources Testing Laboratory Range PN-EN 2570:2001 punkt 5.2.1.3 | PN-EN 60622:2007 punkt 3 | PN-EN 60623:2017-07 punkt 6 | PN-EN 61951-1:2017-10 punkt 6 | PN-EN 61951-1 :2017-10/A1:2023-11 | PN-EN 61951-2 :2017-10 punkt 6 | PN-EN 61951-2 :2017-10/A1:2023-08","test_object_en":"Secondary alkaline cells and batteries","parameters_zh":[{"name":"范围","range":"(0,5 - 630) mm"}],"search_zh":"尺寸 化学电源检测实验室 范围 PN-EN 2570:2001 punkt 5.2.1.3 | PN-EN 60622:2007 punkt 3 | PN-EN 60623:2017-07 punkt 6 | PN-EN 61951-1:2017-10 punkt 6 | PN-EN 61951-1 :2017-10/A1:2023-11 | PN-EN 61951-2 :2017-10 punkt 6 | PN-EN 61951-2 :2017-10/A1:2023-08","methodology_zh":"尺寸","lab_section_zh":"化学电源检测实验室"},{"_id":"6a7d793b0636ba417e41a7b9","lab_id":"69ad52a3de79e566650fb12b","country":"PL","accr_number":"AB 124","accr_body":"PCA","test_object":"Ogniwa i baterie wtórne kwasowe, Ogniwa i baterie wtórne zasadowe","methodology":"Rezystancja izolacji","parameters":[{"name":"Zakres","range":"(1 - 100) MΩ"}],"technique":null,"techniques":[],"computed":[],"activity":"Rezystancja izolacji\nZakres (1 - 100) MΩ","reference":"PN-EN 60952-1:2014-02 punkt 5.9 | PN-EN 2570:2001 punkt 5.4.8","norm_bases":["PN-EN 60952-1:2014-02 punkt 5.9","PN-EN 2570:2001 punkt 5.4.8"],"lab_section":"Laboratorium Badań Chemicznych Źródeł Prądu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ogniwa i baterie wtórne kwasowe, Ogniwa i baterie wtórne zasadowe Rezystancja izolacji\nZakres (1 - 100) MΩ PN-EN 60952-1:2014-02 punkt 5.9 | PN-EN 2570:2001 punkt 5.4.8 Ogniwa i baterie wtorne kwasowe, Ogniwa i baterie wtorne zasadowe Rezystancja izolacji\nZakres (1 - 100) MΩ PN-EN 60952-1:2014-02 punkt 5.9 | PN-EN 2570:2001 punkt 5.4.8","categories":["construction"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Power Sources Testing Laboratory","methodology_en":"Insulation resistance","parameters_en":[{"name":"Range","range":"(1 - 100) MΩ"}],"search_en":"Secondary acid cells and batteries, Secondary alkaline cells and batteries Insulation resistance Chemical Power Sources Testing Laboratory Range PN-EN 60952-1:2014-02 punkt 5.9 | PN-EN 2570:2001 punkt 5.4.8","test_object_en":"Secondary acid cells and batteries, Secondary alkaline cells and batteries","parameters_zh":[{"name":"范围","range":"(1 - 100) MΩ"}],"search_zh":"绝缘电阻 化学电源检测实验室 范围 PN-EN 60952-1:2014-02 punkt 5.9 | PN-EN 2570:2001 punkt 5.4.8","lab_section_zh":"化学电源检测实验室","methodology_zh":"绝缘电阻"},{"_id":"6a7d793b0636ba417e41a7ba","lab_id":"69ad52a3de79e566650fb12b","country":"PL","accr_number":"AB 124","accr_body":"PCA","test_object":"Ogniwa i baterie pierwotne, Ogniwa i baterie wtórne zasadowe","methodology":"Odporność na zwarcie zewnętrzne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na zwarcie zewnętrzne","reference":"PN-EN IEC 60086-4:2026-02 punkt 6.5.2 | PN-EN IEC 60086-5:2022-06 punkt 6.4.2.2 | PN-EN IEC 60086-5:2022-06/AC:2022-08 | PN-EN 62133-1:2017-08 punkt 7.3.2 | PN-EN 62133-2:2017-08 punkt 7.3.1, 7.3.2 | PN-EN 62133-2:2017-08/A1:2022-04 | PN-EN IEC 62281:2019-08 punkt 6.4.5 (Test T.5) | PN-EN IEC 62281:2019-08/A1:2021-11 | PN-EN IEC 62281:2019-08/A2:2023-12 | PN-EN IEC 62619:2023-02 punkt 7.2.1 | PN-EN IEC 62660-2:2019-04 punkt 6.4.1","norm_bases":["PN-EN IEC 60086-4:2026-02 punkt 6.5.2","PN-EN IEC 60086-5:2022-06 punkt 6.4.2.2","PN-EN IEC 60086-5:2022-06/AC:2022-08","PN-EN 62133-1:2017-08 punkt 7.3.2","PN-EN 62133-2:2017-08 punkt 7.3.1, 7.3.2","PN-EN 62133-2:2017-08/A1:2022-04","PN-EN IEC 62281:2019-08 punkt 6.4.5 (Test T.5)","PN-EN IEC 62281:2019-08/A1:2021-11","PN-EN IEC 62281:2019-08/A2:2023-12","PN-EN IEC 62619:2023-02 punkt 7.2.1","PN-EN IEC 62660-2:2019-04 punkt 6.4.1"],"lab_section":"Laboratorium Badań Chemicznych Źródeł Prądu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ogniwa i baterie pierwotne, Ogniwa i baterie wtórne zasadowe Odporność na zwarcie zewnętrzne PN-EN IEC 60086-4:2026-02 punkt 6.5.2 | PN-EN IEC 60086-5:2022-06 punkt 6.4.2.2 | PN-EN IEC 60086-5:2022-06/AC:2022-08 | PN-EN 62133-1:2017-08 punkt 7.3.2 | PN-EN 62133-2:2017-08 punkt 7.3.1, 7.3.2 | PN-EN 62133-2:2017-08/A1:2022-04 | PN-EN IEC 62281:2019-08 punkt 6.4.5 (Test T.5) | PN-EN IEC 62281:2019-08/A1:2021-11 | PN-EN IEC 62281:2019-08/A2:2023-12 | PN-EN IEC 62619:2023-02 punkt 7.2.1 | PN-EN IEC 62660-2:2019-04 punkt 6.4.1 Ogniwa i baterie pierwotne, Ogniwa i baterie wtorne zasadowe Odpornosc na zwarcie zewnetrzne PN-EN IEC 60086-4:2026-02 punkt 6.5.2 | PN-EN IEC 60086-5:2022-06 punkt 6.4.2.2 | PN-EN IEC 60086-5:2022-06/AC:2022-08 | PN-EN 62133-1:2017-08 punkt 7.3.2 | PN-EN 62133-2:2017-08 punkt 7.3.1, 7.3.2 | PN-EN 62133-2:2017-08/A1:2022-04 | PN-EN IEC 62281:2019-08 punkt 6.4.5 (Test T.5) | PN-EN IEC 62281:2019-08/A1:2021-11 | PN-EN IEC 62281:2019-08/A2:2023-12 | PN-EN IEC 62619:2023-02 punkt 7.2.1 | PN-EN IEC 62660-2:2019-04 punkt 6.4.1","categories":["other"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Power Sources Testing Laboratory","methodology_en":"Resistance to external short circuit","search_en":"Primary cells and batteries, Secondary alkaline cells and batteries Resistance to external short circuit Chemical Power Sources Testing Laboratory PN-EN IEC 60086-4:2026-02 punkt 6.5.2 | PN-EN IEC 60086-5:2022-06 punkt 6.4.2.2 | PN-EN IEC 60086-5:2022-06/AC:2022-08 | PN-EN 62133-1:2017-08 punkt 7.3.2 | PN-EN 62133-2:2017-08 punkt 7.3.1, 7.3.2 | PN-EN 62133-2:2017-08/A1:2022-04 | PN-EN IEC 62281:2019-08 punkt 6.4.5 (Test T.5) | PN-EN IEC 62281:2019-08/A1:2021-11 | PN-EN IEC 62281:2019-08/A2:2023-12 | PN-EN IEC 62619:2023-02 punkt 7.2.1 | PN-EN IEC 62660-2:2019-04 punkt 6.4.1","test_object_en":"Primary cells and batteries, Secondary alkaline cells and batteries","lab_section_zh":"化学电源检测实验室","search_zh":"耐外部短路性 化学电源检测实验室 PN-EN IEC 60086-4:2026-02 punkt 6.5.2 | PN-EN IEC 60086-5:2022-06 punkt 6.4.2.2 | PN-EN IEC 60086-5:2022-06/AC:2022-08 | PN-EN 62133-1:2017-08 punkt 7.3.2 | PN-EN 62133-2:2017-08 punkt 7.3.1, 7.3.2 | PN-EN 62133-2:2017-08/A1:2022-04 | PN-EN IEC 62281:2019-08 punkt 6.4.5 (Test T.5) | PN-EN IEC 62281:2019-08/A1:2021-11 | PN-EN IEC 62281:2019-08/A2:2023-12 | PN-EN IEC 62619:2023-02 punkt 7.2.1 | PN-EN IEC 62660-2:2019-04 punkt 6.4.1","methodology_zh":"耐外部短路性"},{"_id":"6a7d793b0636ba417e41a7bb","lab_id":"69ad52a3de79e566650fb12b","country":"PL","accr_number":"AB 124","accr_body":"PCA","test_object":"Ogniwa i baterie pierwotne, Ogniwa i baterie wtórne zasadowe","methodology":"Badania mechaniczne:","parameters":[{"name":"swobodny upadek"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Badania mechaniczne:\nswobodny upadek\nMetoda pomiarowa bezpośrednia","reference":"PN-EN IEC 60086-4:2026-02 punkt 6.5.7 | PN-EN 60086-5:2022-06 punkt 6.4.2.4 | PN-EN 60086-5:2022-06/AC:2022-08 | PN-EN 62133-1:2017-08 punkt 7.3.3 | PN-EN 62133-2:2017-08 punkt 7.3.3 | PN-EN 62133-2:2017-08/A1:2022-04 | PN-EN IEC 62619:2023-02 punkt 7.2.3, 7.3.3 | PN-EN IEC 63056:2020-12 | PN-EN IEC 63056:2020-12/AC:2021-09 punkt 7.9","norm_bases":["PN-EN IEC 60086-4:2026-02 punkt 6.5.7","PN-EN 60086-5:2022-06 punkt 6.4.2.4","PN-EN 60086-5:2022-06/AC:2022-08","PN-EN 62133-1:2017-08 punkt 7.3.3","PN-EN 62133-2:2017-08 punkt 7.3.3","PN-EN 62133-2:2017-08/A1:2022-04","PN-EN IEC 62619:2023-02 punkt 7.2.3, 7.3.3","PN-EN IEC 63056:2020-12","PN-EN IEC 63056:2020-12/AC:2021-09 punkt 7.9"],"lab_section":"Laboratorium Badań Chemicznych Źródeł Prądu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ogniwa i baterie pierwotne, Ogniwa i baterie wtórne zasadowe Badania mechaniczne:\nswobodny upadek\nMetoda pomiarowa bezpośrednia PN-EN IEC 60086-4:2026-02 punkt 6.5.7 | PN-EN 60086-5:2022-06 punkt 6.4.2.4 | PN-EN 60086-5:2022-06/AC:2022-08 | PN-EN 62133-1:2017-08 punkt 7.3.3 | PN-EN 62133-2:2017-08 punkt 7.3.3 | PN-EN 62133-2:2017-08/A1:2022-04 | PN-EN IEC 62619:2023-02 punkt 7.2.3, 7.3.3 | PN-EN IEC 63056:2020-12 | PN-EN IEC 63056:2020-12/AC:2021-09 punkt 7.9 Ogniwa i baterie pierwotne, Ogniwa i baterie wtorne zasadowe Badania mechaniczne:\nswobodny upadek\nMetoda pomiarowa bezposrednia PN-EN IEC 60086-4:2026-02 punkt 6.5.7 | PN-EN 60086-5:2022-06 punkt 6.4.2.4 | PN-EN 60086-5:2022-06/AC:2022-08 | PN-EN 62133-1:2017-08 punkt 7.3.3 | PN-EN 62133-2:2017-08 punkt 7.3.3 | PN-EN 62133-2:2017-08/A1:2022-04 | PN-EN IEC 62619:2023-02 punkt 7.2.3, 7.3.3 | PN-EN IEC 63056:2020-12 | PN-EN IEC 63056:2020-12/AC:2021-09 punkt 7.9","categories":["other"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Power Sources Testing Laboratory","methodology_en":"Mechanical testing:","parameters_en":[{"name":"free fall"}],"search_en":"Primary cells and batteries, Secondary alkaline cells and batteries Mechanical testing: Direct measurement method Chemical Power Sources Testing Laboratory free fall PN-EN IEC 60086-4:2026-02 punkt 6.5.7 | PN-EN 60086-5:2022-06 punkt 6.4.2.4 | PN-EN 60086-5:2022-06/AC:2022-08 | PN-EN 62133-1:2017-08 punkt 7.3.3 | PN-EN 62133-2:2017-08 punkt 7.3.3 | PN-EN 62133-2:2017-08/A1:2022-04 | PN-EN IEC 62619:2023-02 punkt 7.2.3, 7.3.3 | PN-EN IEC 63056:2020-12 | PN-EN IEC 63056:2020-12/AC:2021-09 punkt 7.9","technique_en":"Direct measurement method","test_object_en":"Primary cells and batteries, Secondary alkaline cells and batteries","search_zh":"直接测量法 化学电源检测实验室 PN-EN IEC 60086-4:2026-02 punkt 6.5.7 | PN-EN 60086-5:2022-06 punkt 6.4.2.4 | PN-EN 60086-5:2022-06/AC:2022-08 | PN-EN 62133-1:2017-08 punkt 7.3.3 | PN-EN 62133-2:2017-08 punkt 7.3.3 | PN-EN 62133-2:2017-08/A1:2022-04 | PN-EN IEC 62619:2023-02 punkt 7.2.3, 7.3.3 | PN-EN IEC 63056:2020-12 | PN-EN IEC 63056:2020-12/AC:2021-09 punkt 7.9","technique_zh":"直接测量法","lab_section_zh":"化学电源检测实验室"},{"_id":"6a7d793b0636ba417e41a7bc","lab_id":"69ad52a3de79e566650fb12b","country":"PL","accr_number":"AB 124","accr_body":"PCA","test_object":"Układ magazynowania energii wielokrotnego ładowania (REESS)","methodology":"Cykl standardowy","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cykl standardowy","reference":"Regulamin EKG ONZ nr 100 Załącznik 9","norm_bases":["Regulamin EKG ONZ nr 100 Załącznik 9"],"lab_section":"Laboratorium Badań Chemicznych Źródeł Prądu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Układ magazynowania energii wielokrotnego ładowania (REESS) Cykl standardowy Regulamin EKG ONZ nr 100 Załącznik 9 Uklad magazynowania energii wielokrotnego ladowania (REESS) Cykl standardowy Regulamin EKG ONZ nr 100 Zalacznik 9","categories":["other"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Power Sources Testing Laboratory","methodology_en":"Standard cycle","search_en":"Rechargeable electrical energy storage system (REESS) Standard cycle Chemical Power Sources Testing Laboratory Regulamin EKG ONZ nr 100 Załącznik 9","test_object_en":"Rechargeable electrical energy storage system (REESS)","lab_section_zh":"化学电源检测实验室","search_zh":"可充电电能存储系统（REESS） 标准循环 化学电源检测实验室 Regulamin EKG ONZ nr 100 Załącznik 9","test_object_zh":"可充电电能存储系统（REESS）","methodology_zh":"标准循环"},{"_id":"6a7d793b0636ba417e41a7bd","lab_id":"69ad52a3de79e566650fb12b","country":"PL","accr_number":"AB 124","accr_body":"PCA","test_object":"Układ magazynowania energii wielokrotnego ładowania (REESS)","methodology":"Odporność na gwałtowne zmiany temperatury i próba cyklu termicznego","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na gwałtowne zmiany temperatury i próba cyklu termicznego","reference":"Regulamin EKG ONZ nr 100 Załącznik 9B","norm_bases":["Regulamin EKG ONZ nr 100 Załącznik 9B"],"lab_section":"Laboratorium Badań Chemicznych Źródeł Prądu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Układ magazynowania energii wielokrotnego ładowania (REESS) Odporność na gwałtowne zmiany temperatury i próba cyklu termicznego Regulamin EKG ONZ nr 100 Załącznik 9B Uklad magazynowania energii wielokrotnego ladowania (REESS) Odpornosc na gwaltowne zmiany temperatury i proba cyklu termicznego Regulamin EKG ONZ nr 100 Zalacznik 9B","categories":["other"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Power Sources Testing Laboratory","methodology_en":"Resistance to rapid temperature changes and thermal cycling test","search_en":"Rechargeable electrical energy storage system (REESS) Resistance to rapid temperature changes and thermal cycling test Chemical Power Sources Testing Laboratory Regulamin EKG ONZ nr 100 Załącznik 9B","test_object_en":"Rechargeable electrical energy storage system (REESS)","lab_section_zh":"化学电源检测实验室","search_zh":"可充电电能存储系统（REESS） 耐急剧温度变化性与热循环试验 化学电源检测实验室 Regulamin EKG ONZ nr 100 Załącznik 9B","test_object_zh":"可充电电能存储系统（REESS）","methodology_zh":"耐急剧温度变化性与热循环试验"},{"_id":"6a7d793b0636ba417e41a7be","lab_id":"69ad52a3de79e566650fb12b","country":"PL","accr_number":"AB 124","accr_body":"PCA","test_object":"Układ magazynowania energii wielokrotnego ładowania (REESS)","methodology":"Ognioodporność","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ognioodporność","reference":"Regulamin EKG ONZ nr 100 Załącznik 9E","norm_bases":["Regulamin EKG ONZ nr 100 Załącznik 9E"],"lab_section":"Laboratorium Badań Chemicznych Źródeł Prądu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Układ magazynowania energii wielokrotnego ładowania (REESS) Ognioodporność Regulamin EKG ONZ nr 100 Załącznik 9E Uklad magazynowania energii wielokrotnego ladowania (REESS) Ognioodpornosc Regulamin EKG ONZ nr 100 Zalacznik 9E","categories":["other"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Power Sources Testing Laboratory","methodology_en":"Fire resistance","search_en":"Rechargeable electrical energy storage system (REESS) Fire resistance Chemical Power Sources Testing Laboratory Regulamin EKG ONZ nr 100 Załącznik 9E","test_object_en":"Rechargeable electrical energy storage system (REESS)","lab_section_zh":"化学电源检测实验室","search_zh":"可充电电能存储系统（REESS） 耐火性 化学电源检测实验室 Regulamin EKG ONZ nr 100 Załącznik 9E","test_object_zh":"可充电电能存储系统（REESS）","methodology_zh":"耐火性"},{"_id":"6a7d793b0636ba417e41a7bf","lab_id":"69ad52a3de79e566650fb12b","country":"PL","accr_number":"AB 124","accr_body":"PCA","test_object":"Układ magazynowania energii wielokrotnego ładowania (REESS)","methodology":"Odporność na zwarcie zewnętrzne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na zwarcie zewnętrzne","reference":"Regulamin EKG ONZ nr 100 Załącznik 9F","norm_bases":["Regulamin EKG ONZ nr 100 Załącznik 9F"],"lab_section":"Laboratorium Badań Chemicznych Źródeł Prądu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Układ magazynowania energii wielokrotnego ładowania (REESS) Odporność na zwarcie zewnętrzne Regulamin EKG ONZ nr 100 Załącznik 9F Uklad magazynowania energii wielokrotnego ladowania (REESS) Odpornosc na zwarcie zewnetrzne Regulamin EKG ONZ nr 100 Zalacznik 9F","categories":["other"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Power Sources Testing Laboratory","methodology_en":"Resistance to external short circuit","search_en":"Rechargeable electrical energy storage system (REESS) Resistance to external short circuit Chemical Power Sources Testing Laboratory Regulamin EKG ONZ nr 100 Załącznik 9F","test_object_en":"Rechargeable electrical energy storage system (REESS)","lab_section_zh":"化学电源检测实验室","search_zh":"可充电电能存储系统（REESS） 耐外部短路性 化学电源检测实验室 Regulamin EKG ONZ nr 100 Załącznik 9F","test_object_zh":"可充电电能存储系统（REESS）","methodology_zh":"耐外部短路性"},{"_id":"6a7d793b0636ba417e41a7c0","lab_id":"69ad52a3de79e566650fb12b","country":"PL","accr_number":"AB 124","accr_body":"PCA","test_object":"Układ magazynowania energii wielokrotnego ładowania (REESS)","methodology":"Odporność na przeładowanie","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na przeładowanie","reference":"Regulamin EKG ONZ nr 100 Załącznik 9G","norm_bases":["Regulamin EKG ONZ nr 100 Załącznik 9G"],"lab_section":"Laboratorium Badań Chemicznych Źródeł Prądu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Układ magazynowania energii wielokrotnego ładowania (REESS) Odporność na przeładowanie Regulamin EKG ONZ nr 100 Załącznik 9G Uklad magazynowania energii wielokrotnego ladowania (REESS) Odpornosc na przeladowanie Regulamin EKG ONZ nr 100 Zalacznik 9G","categories":["other"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Power Sources Testing Laboratory","methodology_en":"Resistance to overcharging","search_en":"Rechargeable electrical energy storage system (REESS) Resistance to overcharging Chemical Power Sources Testing Laboratory Regulamin EKG ONZ nr 100 Załącznik 9G","test_object_en":"Rechargeable electrical energy storage system (REESS)","lab_section_zh":"化学电源检测实验室","search_zh":"可充电电能存储系统（REESS） 耐过充电性 化学电源检测实验室 Regulamin EKG ONZ nr 100 Załącznik 9G","test_object_zh":"可充电电能存储系统（REESS）","methodology_zh":"耐过充电性"},{"_id":"6a7d793b0636ba417e41a7c1","lab_id":"69ad52a3de79e566650fb12b","country":"PL","accr_number":"AB 124","accr_body":"PCA","test_object":"Układ magazynowania energii wielokrotnego ładowania (REESS)","methodology":"Odporność przed nadmiernym rozładowaniem","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność przed nadmiernym rozładowaniem","reference":"Regulamin EKG ONZ nr 100 Załącznik 9H","norm_bases":["Regulamin EKG ONZ nr 100 Załącznik 9H"],"lab_section":"Laboratorium Badań Chemicznych Źródeł Prądu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Układ magazynowania energii wielokrotnego ładowania (REESS) Odporność przed nadmiernym rozładowaniem Regulamin EKG ONZ nr 100 Załącznik 9H Uklad magazynowania energii wielokrotnego ladowania (REESS) Odpornosc przed nadmiernym rozladowaniem Regulamin EKG ONZ nr 100 Zalacznik 9H","categories":["other"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Power Sources Testing Laboratory","methodology_en":"Protection against excessive discharge","search_en":"Rechargeable electrical energy storage system (REESS) Protection against excessive discharge Chemical Power Sources Testing Laboratory Regulamin EKG ONZ nr 100 Załącznik 9H","test_object_en":"Rechargeable electrical energy storage system (REESS)","lab_section_zh":"化学电源检测实验室","search_zh":"可充电电能存储系统（REESS） 耐过放电性 化学电源检测实验室 Regulamin EKG ONZ nr 100 Załącznik 9H","test_object_zh":"可充电电能存储系统（REESS）","methodology_zh":"耐过放电性"},{"_id":"6a7d793b0636ba417e41a7c2","lab_id":"69ad52a3de79e566650fb12b","country":"PL","accr_number":"AB 124","accr_body":"PCA","test_object":"Układ magazynowania energii wielokrotnego ładowania (REESS)","methodology":"Cykl standardowy","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cykl standardowy","reference":"Regulamin EKG ONZ nr 136 Załącznik 8","norm_bases":["Regulamin EKG ONZ nr 136 Załącznik 8"],"lab_section":"Laboratorium Badań Chemicznych Źródeł Prądu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Układ magazynowania energii wielokrotnego ładowania (REESS) Cykl standardowy Regulamin EKG ONZ nr 136 Załącznik 8 Uklad magazynowania energii wielokrotnego ladowania (REESS) Cykl standardowy Regulamin EKG ONZ nr 136 Zalacznik 8","categories":["other"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Power Sources Testing Laboratory","methodology_en":"Standard cycle","search_en":"Rechargeable electrical energy storage system (REESS) Standard cycle Chemical Power Sources Testing Laboratory Regulamin EKG ONZ nr 136 Załącznik 8","test_object_en":"Rechargeable electrical energy storage system (REESS)","lab_section_zh":"化学电源检测实验室","search_zh":"可充电电能存储系统（REESS） 标准循环 化学电源检测实验室 Regulamin EKG ONZ nr 136 Załącznik 8","test_object_zh":"可充电电能存储系统（REESS）","methodology_zh":"标准循环"},{"_id":"6a7d793b0636ba417e41a7c3","lab_id":"69ad52a3de79e566650fb12b","country":"PL","accr_number":"AB 124","accr_body":"PCA","test_object":"Układ magazynowania energii wielokrotnego ładowania (REESS)","methodology":"Odporność na gwałtowne zmiany temperatury i próba cyklu termicznego","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na gwałtowne zmiany temperatury i próba cyklu termicznego","reference":"Regulamin EKG ONZ nr 136 Załącznik 8B","norm_bases":["Regulamin EKG ONZ nr 136 Załącznik 8B"],"lab_section":"Laboratorium Badań Chemicznych Źródeł Prądu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Układ magazynowania energii wielokrotnego ładowania (REESS) Odporność na gwałtowne zmiany temperatury i próba cyklu termicznego Regulamin EKG ONZ nr 136 Załącznik 8B Uklad magazynowania energii wielokrotnego ladowania (REESS) Odpornosc na gwaltowne zmiany temperatury i proba cyklu termicznego Regulamin EKG ONZ nr 136 Zalacznik 8B","categories":["other"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Power Sources Testing Laboratory","methodology_en":"Resistance to rapid temperature changes and thermal cycling test","search_en":"Rechargeable electrical energy storage system (REESS) Resistance to rapid temperature changes and thermal cycling test Chemical Power Sources Testing Laboratory Regulamin EKG ONZ nr 136 Załącznik 8B","test_object_en":"Rechargeable electrical energy storage system (REESS)","lab_section_zh":"化学电源检测实验室","search_zh":"可充电电能存储系统（REESS） 耐急剧温度变化性与热循环试验 化学电源检测实验室 Regulamin EKG ONZ nr 136 Załącznik 8B","test_object_zh":"可充电电能存储系统（REESS）","methodology_zh":"耐急剧温度变化性与热循环试验"},{"_id":"6a7d793b0636ba417e41a7c4","lab_id":"69ad52a3de79e566650fb12b","country":"PL","accr_number":"AB 124","accr_body":"PCA","test_object":"Układ magazynowania energii wielokrotnego ładowania (REESS)","methodology":"Odporność na mechaniczną próbę zrzutową wynajmowanego REESS","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na mechaniczną próbę zrzutową wynajmowanego REESS","reference":"Regulamin EKG ONZ nr 136 Załącznik 8C","norm_bases":["Regulamin EKG ONZ nr 136 Załącznik 8C"],"lab_section":"Laboratorium Badań Chemicznych Źródeł Prądu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Układ magazynowania energii wielokrotnego ładowania (REESS) Odporność na mechaniczną próbę zrzutową wynajmowanego REESS Regulamin EKG ONZ nr 136 Załącznik 8C Uklad magazynowania energii wielokrotnego ladowania (REESS) Odpornosc na mechaniczna probe zrzutowa wynajmowanego REESS Regulamin EKG ONZ nr 136 Zalacznik 8C","categories":["other"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Power Sources Testing Laboratory","methodology_en":"Resistance to the mechanical drop test of a rented REESS","search_en":"Rechargeable electrical energy storage system (REESS) Resistance to the mechanical drop test of a rented REESS Chemical Power Sources Testing Laboratory Regulamin EKG ONZ nr 136 Załącznik 8C","test_object_en":"Rechargeable electrical energy storage system (REESS)","lab_section_zh":"化学电源检测实验室","search_zh":"可充电电能存储系统（REESS） 化学电源检测实验室 Regulamin EKG ONZ nr 136 Załącznik 8C","test_object_zh":"可充电电能存储系统（REESS）"},{"_id":"6a7d793b0636ba417e41a7c5","lab_id":"69ad52a3de79e566650fb12b","country":"PL","accr_number":"AB 124","accr_body":"PCA","test_object":"Układ magazynowania energii wielokrotnego ładowania (REESS)","methodology":"Ognioodporność","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ognioodporność","reference":"Regulamin EKG ONZ nr 136 Załącznik 8E","norm_bases":["Regulamin EKG ONZ nr 136 Załącznik 8E"],"lab_section":"Laboratorium Badań Chemicznych Źródeł Prądu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Układ magazynowania energii wielokrotnego ładowania (REESS) Ognioodporność Regulamin EKG ONZ nr 136 Załącznik 8E Uklad magazynowania energii wielokrotnego ladowania (REESS) Ognioodpornosc Regulamin EKG ONZ nr 136 Zalacznik 8E","categories":["other"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Power Sources Testing Laboratory","methodology_en":"Fire resistance","search_en":"Rechargeable electrical energy storage system (REESS) Fire resistance Chemical Power Sources Testing Laboratory Regulamin EKG ONZ nr 136 Załącznik 8E","test_object_en":"Rechargeable electrical energy storage system (REESS)","lab_section_zh":"化学电源检测实验室","search_zh":"可充电电能存储系统（REESS） 耐火性 化学电源检测实验室 Regulamin EKG ONZ nr 136 Załącznik 8E","test_object_zh":"可充电电能存储系统（REESS）","methodology_zh":"耐火性"},{"_id":"6a7d793b0636ba417e41a7c6","lab_id":"69ad52a3de79e566650fb12b","country":"PL","accr_number":"AB 124","accr_body":"PCA","test_object":"Układ magazynowania energii wielokrotnego ładowania (REESS)","methodology":"Odporność na zwarcie zewnętrzne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na zwarcie zewnętrzne","reference":"Regulamin EKG ONZ nr 136 Załącznik 8F","norm_bases":["Regulamin EKG ONZ nr 136 Załącznik 8F"],"lab_section":"Laboratorium Badań Chemicznych Źródeł Prądu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Układ magazynowania energii wielokrotnego ładowania (REESS) Odporność na zwarcie zewnętrzne Regulamin EKG ONZ nr 136 Załącznik 8F Uklad magazynowania energii wielokrotnego ladowania (REESS) Odpornosc na zwarcie zewnetrzne Regulamin EKG ONZ nr 136 Zalacznik 8F","categories":["other"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Power Sources Testing Laboratory","methodology_en":"Resistance to external short circuit","search_en":"Rechargeable electrical energy storage system (REESS) Resistance to external short circuit Chemical Power Sources Testing Laboratory Regulamin EKG ONZ nr 136 Załącznik 8F","test_object_en":"Rechargeable electrical energy storage system (REESS)","lab_section_zh":"化学电源检测实验室","search_zh":"可充电电能存储系统（REESS） 耐外部短路性 化学电源检测实验室 Regulamin EKG ONZ nr 136 Załącznik 8F","test_object_zh":"可充电电能存储系统（REESS）","methodology_zh":"耐外部短路性"},{"_id":"6a7d793b0636ba417e41a7c7","lab_id":"69ad52a3de79e566650fb12b","country":"PL","accr_number":"AB 124","accr_body":"PCA","test_object":"Układ magazynowania energii wielokrotnego ładowania (REESS)","methodology":"Odporność na przeładowanie","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na przeładowanie","reference":"Regulamin EKG ONZ nr 136 Załącznik 8G","norm_bases":["Regulamin EKG ONZ nr 136 Załącznik 8G"],"lab_section":"Laboratorium Badań Chemicznych Źródeł Prądu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Układ magazynowania energii wielokrotnego ładowania (REESS) Odporność na przeładowanie Regulamin EKG ONZ nr 136 Załącznik 8G Uklad magazynowania energii wielokrotnego ladowania (REESS) Odpornosc na przeladowanie Regulamin EKG ONZ nr 136 Zalacznik 8G","categories":["other"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Power Sources Testing Laboratory","methodology_en":"Resistance to overcharging","search_en":"Rechargeable electrical energy storage system (REESS) Resistance to overcharging Chemical Power Sources Testing Laboratory Regulamin EKG ONZ nr 136 Załącznik 8G","test_object_en":"Rechargeable electrical energy storage system (REESS)","lab_section_zh":"化学电源检测实验室","search_zh":"可充电电能存储系统（REESS） 耐过充电性 化学电源检测实验室 Regulamin EKG ONZ nr 136 Załącznik 8G","test_object_zh":"可充电电能存储系统（REESS）","methodology_zh":"耐过充电性"},{"_id":"6a7d793b0636ba417e41a7c8","lab_id":"69ad52a3de79e566650fb12b","country":"PL","accr_number":"AB 124","accr_body":"PCA","test_object":"Układ magazynowania energii wielokrotnego ładowania (REESS)","methodology":"Odporność przed nadmiernym rozładowaniem","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność przed nadmiernym rozładowaniem","reference":"Regulamin EKG ONZ nr 136 Załącznik 8H","norm_bases":["Regulamin EKG ONZ nr 136 Załącznik 8H"],"lab_section":"Laboratorium Badań Chemicznych Źródeł Prądu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Układ magazynowania energii wielokrotnego ładowania (REESS) Odporność przed nadmiernym rozładowaniem Regulamin EKG ONZ nr 136 Załącznik 8H Uklad magazynowania energii wielokrotnego ladowania (REESS) Odpornosc przed nadmiernym rozladowaniem Regulamin EKG ONZ nr 136 Zalacznik 8H","categories":["other"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Power Sources Testing Laboratory","methodology_en":"Protection against excessive discharge","search_en":"Rechargeable electrical energy storage system (REESS) Protection against excessive discharge Chemical Power Sources Testing Laboratory Regulamin EKG ONZ nr 136 Załącznik 8H","test_object_en":"Rechargeable electrical energy storage system (REESS)","lab_section_zh":"化学电源检测实验室","search_zh":"可充电电能存储系统（REESS） 耐过放电性 化学电源检测实验室 Regulamin EKG ONZ nr 136 Załącznik 8H","test_object_zh":"可充电电能存储系统（REESS）","methodology_zh":"耐过放电性"},{"_id":"6a7d793b0636ba417e41a7c9","lab_id":"69ad52a3de79e566650fb12b","country":"PL","accr_number":"AB 124","accr_body":"PCA","test_object":"Układ magazynowania energii wielokrotnego ładowania (REESS)","methodology":"Cykl standardowy","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Cykl standardowy","reference":"ISO 6469-1:2019-04 | ISO 6469-1:2019/Amd.1:2022-11 punkt 6.1.5","norm_bases":["ISO 6469-1:2019-04","ISO 6469-1:2019/Amd.1:2022-11 punkt 6.1.5"],"lab_section":"Laboratorium Badań Chemicznych Źródeł Prądu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Układ magazynowania energii wielokrotnego ładowania (REESS) Cykl standardowy ISO 6469-1:2019-04 | ISO 6469-1:2019/Amd.1:2022-11 punkt 6.1.5 Uklad magazynowania energii wielokrotnego ladowania (REESS) Cykl standardowy ISO 6469-1:2019-04 | ISO 6469-1:2019/Amd.1:2022-11 punkt 6.1.5","categories":["other"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Power Sources Testing Laboratory","methodology_en":"Standard cycle","search_en":"Rechargeable electrical energy storage system (REESS) Standard cycle Chemical Power Sources Testing Laboratory ISO 6469-1:2019-04 | ISO 6469-1:2019/Amd.1:2022-11 punkt 6.1.5","test_object_en":"Rechargeable electrical energy storage system (REESS)","lab_section_zh":"化学电源检测实验室","search_zh":"可充电电能存储系统（REESS） 标准循环 化学电源检测实验室 ISO 6469-1:2019-04 | ISO 6469-1:2019/Amd.1:2022-11 punkt 6.1.5","test_object_zh":"可充电电能存储系统（REESS）","methodology_zh":"标准循环"},{"_id":"6a7d793b0636ba417e41a7ca","lab_id":"69ad52a3de79e566650fb12b","country":"PL","accr_number":"AB 124","accr_body":"PCA","test_object":"Układ magazynowania energii wielokrotnego ładowania (REESS)","methodology":"Odporność na gwałtowne zmiany temperatury i próba cyklu termicznego","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na gwałtowne zmiany temperatury i próba cyklu termicznego","reference":"ISO 6469-1:2019-04 | ISO 6469-1:2019/Amd.1:2022-11 punkt 6.3.1","norm_bases":["ISO 6469-1:2019-04","ISO 6469-1:2019/Amd.1:2022-11 punkt 6.3.1"],"lab_section":"Laboratorium Badań Chemicznych Źródeł Prądu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Układ magazynowania energii wielokrotnego ładowania (REESS) Odporność na gwałtowne zmiany temperatury i próba cyklu termicznego ISO 6469-1:2019-04 | ISO 6469-1:2019/Amd.1:2022-11 punkt 6.3.1 Uklad magazynowania energii wielokrotnego ladowania (REESS) Odpornosc na gwaltowne zmiany temperatury i proba cyklu termicznego ISO 6469-1:2019-04 | ISO 6469-1:2019/Amd.1:2022-11 punkt 6.3.1","categories":["other"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Power Sources Testing Laboratory","methodology_en":"Resistance to rapid temperature changes and thermal cycling test","search_en":"Rechargeable electrical energy storage system (REESS) Resistance to rapid temperature changes and thermal cycling test Chemical Power Sources Testing Laboratory ISO 6469-1:2019-04 | ISO 6469-1:2019/Amd.1:2022-11 punkt 6.3.1","test_object_en":"Rechargeable electrical energy storage system (REESS)","lab_section_zh":"化学电源检测实验室","search_zh":"可充电电能存储系统（REESS） 耐急剧温度变化性与热循环试验 化学电源检测实验室 ISO 6469-1:2019-04 | ISO 6469-1:2019/Amd.1:2022-11 punkt 6.3.1","test_object_zh":"可充电电能存储系统（REESS）","methodology_zh":"耐急剧温度变化性与热循环试验"},{"_id":"6a7d793b0636ba417e41a7cb","lab_id":"69ad52a3de79e566650fb12b","country":"PL","accr_number":"AB 124","accr_body":"PCA","test_object":"Układ magazynowania energii wielokrotnego ładowania (REESS)","methodology":"Ognioodporność","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ognioodporność","reference":"ISO 6469-1:2019-04 | ISO 6469-1:2019/Amd.1:2022-11 punkt 6.4.3","norm_bases":["ISO 6469-1:2019-04","ISO 6469-1:2019/Amd.1:2022-11 punkt 6.4.3"],"lab_section":"Laboratorium Badań Chemicznych Źródeł Prądu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Układ magazynowania energii wielokrotnego ładowania (REESS) Ognioodporność ISO 6469-1:2019-04 | ISO 6469-1:2019/Amd.1:2022-11 punkt 6.4.3 Uklad magazynowania energii wielokrotnego ladowania (REESS) Ognioodpornosc ISO 6469-1:2019-04 | ISO 6469-1:2019/Amd.1:2022-11 punkt 6.4.3","categories":["other"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Power Sources Testing Laboratory","methodology_en":"Fire resistance","search_en":"Rechargeable electrical energy storage system (REESS) Fire resistance Chemical Power Sources Testing Laboratory ISO 6469-1:2019-04 | ISO 6469-1:2019/Amd.1:2022-11 punkt 6.4.3","test_object_en":"Rechargeable electrical energy storage system (REESS)","lab_section_zh":"化学电源检测实验室","search_zh":"可充电电能存储系统（REESS） 耐火性 化学电源检测实验室 ISO 6469-1:2019-04 | ISO 6469-1:2019/Amd.1:2022-11 punkt 6.4.3","test_object_zh":"可充电电能存储系统（REESS）","methodology_zh":"耐火性"},{"_id":"6a7d793b0636ba417e41a7cc","lab_id":"69ad52a3de79e566650fb12b","country":"PL","accr_number":"AB 124","accr_body":"PCA","test_object":"Układ magazynowania energii wielokrotnego ładowania (REESS)","methodology":"Odporność na zwarcie zewnętrzne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na zwarcie zewnętrzne","reference":"ISO 6469-1:2019-04 | ISO 6469-1:2019/Amd.1:2022-11 punkt 6.5.1","norm_bases":["ISO 6469-1:2019-04","ISO 6469-1:2019/Amd.1:2022-11 punkt 6.5.1"],"lab_section":"Laboratorium Badań Chemicznych Źródeł Prądu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Układ magazynowania energii wielokrotnego ładowania (REESS) Odporność na zwarcie zewnętrzne ISO 6469-1:2019-04 | ISO 6469-1:2019/Amd.1:2022-11 punkt 6.5.1 Uklad magazynowania energii wielokrotnego ladowania (REESS) Odpornosc na zwarcie zewnetrzne ISO 6469-1:2019-04 | ISO 6469-1:2019/Amd.1:2022-11 punkt 6.5.1","categories":["other"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Power Sources Testing Laboratory","methodology_en":"Resistance to external short circuit","search_en":"Rechargeable electrical energy storage system (REESS) Resistance to external short circuit Chemical Power Sources Testing Laboratory ISO 6469-1:2019-04 | ISO 6469-1:2019/Amd.1:2022-11 punkt 6.5.1","test_object_en":"Rechargeable electrical energy storage system (REESS)","lab_section_zh":"化学电源检测实验室","search_zh":"可充电电能存储系统（REESS） 耐外部短路性 化学电源检测实验室 ISO 6469-1:2019-04 | ISO 6469-1:2019/Amd.1:2022-11 punkt 6.5.1","test_object_zh":"可充电电能存储系统（REESS）","methodology_zh":"耐外部短路性"},{"_id":"6a7d793b0636ba417e41a7cd","lab_id":"69ad52a3de79e566650fb12b","country":"PL","accr_number":"AB 124","accr_body":"PCA","test_object":"Układ magazynowania energii wielokrotnego ładowania (REESS)","methodology":"Odporność na przeładowanie","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność na przeładowanie","reference":"ISO 6469-1:2019-04 | ISO 6469-1:2019/Amd.1:2022-11 punkt 6.6.2","norm_bases":["ISO 6469-1:2019-04","ISO 6469-1:2019/Amd.1:2022-11 punkt 6.6.2"],"lab_section":"Laboratorium Badań Chemicznych Źródeł Prądu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Układ magazynowania energii wielokrotnego ładowania (REESS) Odporność na przeładowanie ISO 6469-1:2019-04 | ISO 6469-1:2019/Amd.1:2022-11 punkt 6.6.2 Uklad magazynowania energii wielokrotnego ladowania (REESS) Odpornosc na przeladowanie ISO 6469-1:2019-04 | ISO 6469-1:2019/Amd.1:2022-11 punkt 6.6.2","categories":["other"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Power Sources Testing Laboratory","methodology_en":"Resistance to overcharging","search_en":"Rechargeable electrical energy storage system (REESS) Resistance to overcharging Chemical Power Sources Testing Laboratory ISO 6469-1:2019-04 | ISO 6469-1:2019/Amd.1:2022-11 punkt 6.6.2","test_object_en":"Rechargeable electrical energy storage system (REESS)","lab_section_zh":"化学电源检测实验室","search_zh":"可充电电能存储系统（REESS） 耐过充电性 化学电源检测实验室 ISO 6469-1:2019-04 | ISO 6469-1:2019/Amd.1:2022-11 punkt 6.6.2","test_object_zh":"可充电电能存储系统（REESS）","methodology_zh":"耐过充电性"},{"_id":"6a7d793b0636ba417e41a7ce","lab_id":"69ad52a3de79e566650fb12b","country":"PL","accr_number":"AB 124","accr_body":"PCA","test_object":"Układ magazynowania energii wielokrotnego ładowania (REESS)","methodology":"Odporność przed nadmiernym rozładowaniem","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność przed nadmiernym rozładowaniem","reference":"ISO 6469-1:2019-04 | ISO 6469-1:2019/Amd.1:2022-11 punkt 6.6.3","norm_bases":["ISO 6469-1:2019-04","ISO 6469-1:2019/Amd.1:2022-11 punkt 6.6.3"],"lab_section":"Laboratorium Badań Chemicznych Źródeł Prądu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Układ magazynowania energii wielokrotnego ładowania (REESS) Odporność przed nadmiernym rozładowaniem ISO 6469-1:2019-04 | ISO 6469-1:2019/Amd.1:2022-11 punkt 6.6.3 Uklad magazynowania energii wielokrotnego ladowania (REESS) Odpornosc przed nadmiernym rozladowaniem ISO 6469-1:2019-04 | ISO 6469-1:2019/Amd.1:2022-11 punkt 6.6.3","categories":["other"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Power Sources Testing Laboratory","methodology_en":"Protection against excessive discharge","search_en":"Rechargeable electrical energy storage system (REESS) Protection against excessive discharge Chemical Power Sources Testing Laboratory ISO 6469-1:2019-04 | ISO 6469-1:2019/Amd.1:2022-11 punkt 6.6.3","test_object_en":"Rechargeable electrical energy storage system (REESS)","lab_section_zh":"化学电源检测实验室","search_zh":"可充电电能存储系统（REESS） 耐过放电性 化学电源检测实验室 ISO 6469-1:2019-04 | ISO 6469-1:2019/Amd.1:2022-11 punkt 6.6.3","test_object_zh":"可充电电能存储系统（REESS）","methodology_zh":"耐过放电性"},{"_id":"6a7d793b0636ba417e41a7cf","lab_id":"69ad52a3de79e566650fb12b","country":"PL","accr_number":"AB 124","accr_body":"PCA","test_object":"Układ magazynowania energii wielokrotnego ładowania (REESS)","methodology":"Odporność przed wewnętrznym przegrzaniem","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Odporność przed wewnętrznym przegrzaniem","reference":"ISO 6469-1:2019-04 | ISO 6469-1:2019/Amd.1:2022-11 punkt 6.6.4","norm_bases":["ISO 6469-1:2019-04","ISO 6469-1:2019/Amd.1:2022-11 punkt 6.6.4"],"lab_section":"Laboratorium Badań Chemicznych Źródeł Prądu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Układ magazynowania energii wielokrotnego ładowania (REESS) Odporność przed wewnętrznym przegrzaniem ISO 6469-1:2019-04 | ISO 6469-1:2019/Amd.1:2022-11 punkt 6.6.4 Uklad magazynowania energii wielokrotnego ladowania (REESS) Odpornosc przed wewnetrznym przegrzaniem ISO 6469-1:2019-04 | ISO 6469-1:2019/Amd.1:2022-11 punkt 6.6.4","categories":["other"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Power Sources Testing Laboratory","methodology_en":"Protection against internal overheating","search_en":"Rechargeable electrical energy storage system (REESS) Protection against internal overheating Chemical Power Sources Testing Laboratory ISO 6469-1:2019-04 | ISO 6469-1:2019/Amd.1:2022-11 punkt 6.6.4","test_object_en":"Rechargeable electrical energy storage system (REESS)","lab_section_zh":"化学电源检测实验室","search_zh":"可充电电能存储系统（REESS） 化学电源检测实验室 ISO 6469-1:2019-04 | ISO 6469-1:2019/Amd.1:2022-11 punkt 6.6.4","test_object_zh":"可充电电能存储系统（REESS）"},{"_id":"6a7d793b0636ba417e41a7d0","lab_id":"69ad52a3de79e566650fb12b","country":"PL","accr_number":"AB 124","accr_body":"PCA","test_object":"Ogniwa i baterie","methodology":"T.1 Symulacja wysokości","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"T.1 Symulacja wysokości","reference":"Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8/Amed.1","norm_bases":["Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8/Amed.1"],"lab_section":"Laboratorium Badań Chemicznych Źródeł Prądu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ogniwa i baterie T.1 Symulacja wysokości Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8/Amed.1 Ogniwa i baterie T.1 Symulacja wysokosci Podrecznik UN TEST Nr ST/SG/AC.10/11/Rev.8/Amed.1","categories":["other"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Power Sources Testing Laboratory","methodology_en":"T.1 Altitude simulation","search_en":"Cells and batteries T.1 Altitude simulation Chemical Power Sources Testing Laboratory Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8/Amed.1","test_object_en":"Cells and batteries","lab_section_zh":"化学电源检测实验室","search_zh":"电池与电池组 化学电源检测实验室 Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8/Amed.1","test_object_zh":"电池与电池组"},{"_id":"6a7d793b0636ba417e41a7d1","lab_id":"69ad52a3de79e566650fb12b","country":"PL","accr_number":"AB 124","accr_body":"PCA","test_object":"Ogniwa i baterie","methodology":"T.2 Test termiczny","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"T.2 Test termiczny","reference":"Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8/Amed.1","norm_bases":["Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8/Amed.1"],"lab_section":"Laboratorium Badań Chemicznych Źródeł Prądu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ogniwa i baterie T.2 Test termiczny Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8/Amed.1 Ogniwa i baterie T.2 Test termiczny Podrecznik UN TEST Nr ST/SG/AC.10/11/Rev.8/Amed.1","categories":["other"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Power Sources Testing Laboratory","methodology_en":"T.2 Thermal test","search_en":"Cells and batteries T.2 Thermal test Chemical Power Sources Testing Laboratory Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8/Amed.1","test_object_en":"Cells and batteries","lab_section_zh":"化学电源检测实验室","search_zh":"电池与电池组 化学电源检测实验室 Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8/Amed.1","test_object_zh":"电池与电池组"},{"_id":"6a7d793b0636ba417e41a7d2","lab_id":"69ad52a3de79e566650fb12b","country":"PL","accr_number":"AB 124","accr_body":"PCA","test_object":"Ogniwa i baterie","methodology":"T.5 Zwarcie zewnętrzne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"T.5 Zwarcie zewnętrzne","reference":"Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8/Amed.1","norm_bases":["Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8/Amed.1"],"lab_section":"Laboratorium Badań Chemicznych Źródeł Prądu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ogniwa i baterie T.5 Zwarcie zewnętrzne Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8/Amed.1 Ogniwa i baterie T.5 Zwarcie zewnetrzne Podrecznik UN TEST Nr ST/SG/AC.10/11/Rev.8/Amed.1","categories":["other"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Power Sources Testing Laboratory","methodology_en":"T.5 External short circuit","search_en":"Cells and batteries T.5 External short circuit Chemical Power Sources Testing Laboratory Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8/Amed.1","test_object_en":"Cells and batteries","lab_section_zh":"化学电源检测实验室","search_zh":"电池与电池组 化学电源检测实验室 Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8/Amed.1","test_object_zh":"电池与电池组"},{"_id":"6a7d793b0636ba417e41a7d3","lab_id":"69ad52a3de79e566650fb12b","country":"PL","accr_number":"AB 124","accr_body":"PCA","test_object":"Ogniwa i baterie","methodology":"T.7 Przeładowanie","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"T.7 Przeładowanie","reference":"Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8/Amed.1","norm_bases":["Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8/Amed.1"],"lab_section":"Laboratorium Badań Chemicznych Źródeł Prądu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ogniwa i baterie T.7 Przeładowanie Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8/Amed.1 Ogniwa i baterie T.7 Przeladowanie Podrecznik UN TEST Nr ST/SG/AC.10/11/Rev.8/Amed.1","categories":["other"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Power Sources Testing Laboratory","methodology_en":"T.7 Overcharge","search_en":"Cells and batteries T.7 Overcharge Chemical Power Sources Testing Laboratory Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8/Amed.1","test_object_en":"Cells and batteries","lab_section_zh":"化学电源检测实验室","search_zh":"电池与电池组 化学电源检测实验室 Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8/Amed.1","test_object_zh":"电池与电池组"},{"_id":"6a7d793b0636ba417e41a7d4","lab_id":"69ad52a3de79e566650fb12b","country":"PL","accr_number":"AB 124","accr_body":"PCA","test_object":"Ogniwa i baterie","methodology":"T.8 Wymuszone wyładowanie","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"T.8 Wymuszone wyładowanie","reference":"Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8/Amed.1","norm_bases":["Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8/Amed.1"],"lab_section":"Laboratorium Badań Chemicznych Źródeł Prądu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ogniwa i baterie T.8 Wymuszone wyładowanie Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8/Amed.1 Ogniwa i baterie T.8 Wymuszone wyladowanie Podrecznik UN TEST Nr ST/SG/AC.10/11/Rev.8/Amed.1","categories":["other"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Power Sources Testing Laboratory","methodology_en":"T.8 Forced discharge","search_en":"Cells and batteries T.8 Forced discharge Chemical Power Sources Testing Laboratory Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8/Amed.1","test_object_en":"Cells and batteries","lab_section_zh":"化学电源检测实验室","search_zh":"电池与电池组 化学电源检测实验室 Podręcznik UN TEST Nr ST/SG/AC.10/11/Rev.8/Amed.1","test_object_zh":"电池与电池组"}],"has_pdf":true}