🇵🇱 ZAKŁAD BADANIA WÓD I ŚCIEKÓW PL

PCA AB 1237 • Poland • 21 methods

Water & wastewater

ZAKŁAD BADANIA WÓD I ŚCIEKÓW is a laboratory accredited by PCA under number AB 1237 (Poland). Its accreditation scope covers 21 test methods in the following areas: Water & wastewater. Test objects include: Water Wastewater, Water, Wastewater.

At a glance

  • Accreditation number: PCA AB 1237
  • Methods in scope: 21
  • Types of test objects: 3
Accreditation number
AB 1237
Accreditation body
PCA
Address
Jacek Kubiak, Gostyń 5, 72 - 405 Świerzno
City
Poland

What this laboratory tests (3)

Accreditation scope — test methods (21)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Water Wastewater Dissolved oxygen concentration Range: (0,2 – 20,0) mg/l Titrimetric method PN-EN 25813:1997
2 Water Wastewater Ammonium nitrogen concentration Range: (0,05 – 2,0) mg/l Spectrophotometric method PN-ISO 7150-1:2002
3 Water Wastewater Biochemical oxygen demand - BOD 5 Range: (1 – 6000) mg/l O 2 Titrimetric method PN-EN ISO 5815-1:2019-12
4 Water Wastewater Chloride concentration Range: (5 – 400) mg/l Titrimetric method PN-ISO 9297:1994
5 Water Wastewater Chemical oxygen demand - COD-Cr Range: (30 – 700) mg/l O 2 Titrimetric method PN-ISO 6060:2006
6 Water Wastewater Phosphate phosphorus and total phosphorus concentration Range: (0,01 – 1,0) mg/l P PO4 (0,05 – 7,0) mg/l P total Spectrophotometric method PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010
7 Water Wastewater Total suspended solids (TSS) Range: (2,0 – 2000) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007
8 Water Wastewater pH Range: 2,0 – 12,0 Potentiometric method PN-EN ISO 10523:2012
9 Water Wastewater Electrical conductivity Range: (100 – 3000) µS/cm Conductometric method PN-EN 27888:1999
10 Water Wastewater Nitrate nitrogen concentration Range: (0,05 – 20,0) mg/l Spectrophotometric method PN-82/C-04576.08
11 Water Wastewater Nitrite nitrogen concentration Range: (0,002 – 0,25) mg/l Spectrophotometric method PN-EN 26777:1999
12 Water Wastewater Sulphate concentration Range: (0,5 – 50,0) mg/l Turbidimetric method PN-79/C-04566.10
13 Water Wastewater Total nitrogen concentration Range: (0,5 – 150) mg/l Spectrophotometric method PB-01/2012 wyd. I z dnia 01.08.2012 r. na podstawie testu kuwetowego Merck 1.14537.0001
14 Wastewater Sampling for chemical and physical testing Manual method Temperature of the wastewater sample taken Range: (0,5 – 30,0) ºC PN-ISO 5667-10:2021-11 PN-77/C-04584
15 Water Sampling for chemical and physical testing Temperature of the water sample taken Range: (0,5 – 30,0) ºC PN-ISO 5667-4:2017-10 PN-ISO 5667-5:2017-10 PN-EN ISO 5667-6:2016-12 PN-77/C-04584
16 Water Turbidity Range: (0,10 – 10) NTU Nephelometric method PN-EN ISO 7027-1:2016-09
17 Water Colour Range: (5 – 25) mg/l Pt Spectrophotometric method PN-EN ISO 7887:2012 p. 6 +Ap1:2015
18 Water Total calcium and magnesium content (total hardness) Range: (0,05 – 20,0) mmol/l Titrimetric method PN-ISO 6059:1999
19 Water Permanganate index Range: (0,5 – 500) mg/l O 2 Titrimetric method PN-EN ISO 8467:2001
20 Water Iron concentration Range: (0,05 – 5,0) mg/l Spectrophotometric method PB-02 z dn. 15.10.2020 na podstawie testu Merck 1.14761
21 Water Manganese concentration Range: (0,010 – 2,0) mg/l Spectrophotometric method PB-03 z dn. 15.10.2020 na podstawie testu Merck 1.01846

Reference standards (21)

PB-01/2012 wyd. I z dnia 01.08.2012 r. na podstawie testu kuwetowego Merck 1.14537.0001
PB-02 z dn. 15.10.2020 na podstawie testu Merck 1.14761
PB-03 z dn. 15.10.2020 na podstawie testu Merck 1.01846
PN-79/C-04566.10
PN-82/C-04576.08
PN-EN 25813:1997
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 p. 6 +Ap1:2015
PN-EN ISO 8467:2001
PN-ISO 5667-10:2021-11 PN-77/C-04584
PN-ISO 5667-4:2017-10 PN-ISO 5667-5:2017-10 PN-EN ISO 5667-6:2016-12 PN-77/C-04584
PN-ISO 6059:1999
PN-ISO 6060:2006
PN-ISO 7150-1:2002
PN-ISO 9297:1994