🇵🇱 ZAKŁAD BADANIA WÓD I ŚCIEKÓW PL
Water & wastewater
ZAKŁAD BADANIA WÓD I ŚCIEKÓW is a laboratory accredited by PCA under number AB 1237 (Poland). Its accreditation scope covers 21 test methods in the following areas: Water & wastewater. Test objects include: Water Wastewater, Water, Wastewater.
At a glance
- Accreditation number: PCA AB 1237
- Methods in scope: 21
- Types of test objects: 3
- Accreditation number
- AB 1237
- Accreditation body
- PCA
- Address
- Jacek Kubiak, Gostyń 5, 72 - 405 Świerzno
- City
- Poland
What this laboratory tests (3)
- Water Wastewater — 13 methods
- Water — 7 methods
- Wastewater — 1 method
Accreditation scope — test methods (21)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Water Wastewater | Dissolved oxygen concentration Range: (0,2 – 20,0) mg/l Titrimetric method | PN-EN 25813:1997 | ||
| 2 | Water Wastewater | Ammonium nitrogen concentration Range: (0,05 – 2,0) mg/l Spectrophotometric method | PN-ISO 7150-1:2002 | ||
| 3 | Water Wastewater | Biochemical oxygen demand - BOD 5 Range: (1 – 6000) mg/l O 2 Titrimetric method | PN-EN ISO 5815-1:2019-12 | ||
| 4 | Water Wastewater | Chloride concentration Range: (5 – 400) mg/l Titrimetric method | PN-ISO 9297:1994 | ||
| 5 | Water Wastewater | Chemical oxygen demand - COD-Cr Range: (30 – 700) mg/l O 2 Titrimetric method | PN-ISO 6060:2006 | ||
| 6 | Water Wastewater | Phosphate phosphorus and total phosphorus concentration Range: (0,01 – 1,0) mg/l P PO4 (0,05 – 7,0) mg/l P total Spectrophotometric method | PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010 | ||
| 7 | Water Wastewater | Total suspended solids (TSS) Range: (2,0 – 2000) mg/l Gravimetric method | PN-EN 872:2007+Ap1:2007 | ||
| 8 | Water Wastewater | pH Range: 2,0 – 12,0 Potentiometric method | PN-EN ISO 10523:2012 | ||
| 9 | Water Wastewater | Electrical conductivity Range: (100 – 3000) µS/cm Conductometric method | PN-EN 27888:1999 | ||
| 10 | Water Wastewater | Nitrate nitrogen concentration Range: (0,05 – 20,0) mg/l Spectrophotometric method | PN-82/C-04576.08 | ||
| 11 | Water Wastewater | Nitrite nitrogen concentration Range: (0,002 – 0,25) mg/l Spectrophotometric method | PN-EN 26777:1999 | ||
| 12 | Water Wastewater | Sulphate concentration Range: (0,5 – 50,0) mg/l Turbidimetric method | PN-79/C-04566.10 | ||
| 13 | Water Wastewater | Total nitrogen concentration Range: (0,5 – 150) mg/l Spectrophotometric method | PB-01/2012 wyd. I z dnia 01.08.2012 r. na podstawie testu kuwetowego Merck 1.14537.0001 | ||
| 14 | Wastewater | Sampling for chemical and physical testing Manual method Temperature of the wastewater sample taken Range: (0,5 – 30,0) ºC | PN-ISO 5667-10:2021-11 PN-77/C-04584 | ||
| 15 | Water | Sampling for chemical and physical testing Temperature of the water sample taken Range: (0,5 – 30,0) ºC | PN-ISO 5667-4:2017-10 PN-ISO 5667-5:2017-10 PN-EN ISO 5667-6:2016-12 PN-77/C-04584 | ||
| 16 | Water | Turbidity Range: (0,10 – 10) NTU Nephelometric method | PN-EN ISO 7027-1:2016-09 | ||
| 17 | Water | Colour Range: (5 – 25) mg/l Pt Spectrophotometric method | PN-EN ISO 7887:2012 p. 6 +Ap1:2015 | ||
| 18 | Water | Total calcium and magnesium content (total hardness) Range: (0,05 – 20,0) mmol/l Titrimetric method | PN-ISO 6059:1999 | ||
| 19 | Water | Permanganate index Range: (0,5 – 500) mg/l O 2 Titrimetric method | PN-EN ISO 8467:2001 | ||
| 20 | Water | Iron concentration Range: (0,05 – 5,0) mg/l Spectrophotometric method | PB-02 z dn. 15.10.2020 na podstawie testu Merck 1.14761 | ||
| 21 | Water | Manganese concentration Range: (0,010 – 2,0) mg/l Spectrophotometric method | PB-03 z dn. 15.10.2020 na podstawie testu Merck 1.01846 | ||
Reference standards (21)
PB-01/2012 wyd. I z dnia 01.08.2012 r. na podstawie testu kuwetowego Merck 1.14537.0001
PB-02 z dn. 15.10.2020 na podstawie testu Merck 1.14761
PB-03 z dn. 15.10.2020 na podstawie testu Merck 1.01846
PN-79/C-04566.10
PN-82/C-04576.08
PN-EN 25813:1997
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 p. 6 +Ap1:2015
PN-EN ISO 8467:2001
PN-ISO 5667-10:2021-11 PN-77/C-04584
PN-ISO 5667-4:2017-10 PN-ISO 5667-5:2017-10 PN-EN ISO 5667-6:2016-12 PN-77/C-04584
PN-ISO 6059:1999
PN-ISO 6060:2006
PN-ISO 7150-1:2002
PN-ISO 9297:1994