{"lab":{"_id":"69ad52a3de79e566650fb658","accr_number":"AB 1237","country":"PL","accr_body":"PCA","address":"Jacek Kubiak, Gostyń 5, 72 - 405 Świerzno","categories":["water"],"city":"","imported_at":"2026-03-08T10:42:43.265Z","methods_count":21,"name":"ZAKŁAD BADANIA WÓD I ŚCIEKÓW","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1237.pdf"],"scope_summary":"","search_text":"zakład badania wód i ścieków jacek kubiak, gostyń 5, 72 - 405 świerzno water other pharma electronics","status":"active","updated_at":"2026-03-08T14:50:24.827Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:24.827Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201237,podmiot.html","parse_date":"2026-07-17T16:19:00.318Z","parse_source":"m5-mistral-qa","fields_of_testing":[{"codes":"C/28/P; C/29/P; C/30/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Chemical tests and sampling of water, drinking water, sewage"},{"codes":"N/28/P; N/29/P; N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Tests of physical properties and sampling of water, drinking water, sewage"}],"issue":{"no":"15","date":"29.01.2025"},"has_en":true,"category_counts":{"water":21},"category_scores":{"water":21},"has_zh":true},"methods":[{"_id":"6a5a55f49af9f73f3825190b","lab_id":"69ad52a3de79e566650fb658","country":"PL","accr_number":"AB 1237","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie tlenu rozpuszczonego Zakres: (0,2 – 20,0) mg/l Metoda miareczkowa","methodology_en":"Dissolved oxygen concentration Range: (0,2 – 20,0) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie tlenu rozpuszczonego Zakres: (0,2 – 20,0) mg/l Metoda miareczkowa","reference":"PN-EN 25813:1997","norm_bases":["PN-EN 25813:1997"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie tlenu rozpuszczonego Zakres: (0,2 – 20,0) mg/l Metoda miareczkowa PN-EN 25813:1997 Woda Scieki Stezenie tlenu rozpuszczonego Zakres: (0,2 – 20,0) mg/l Metoda miareczkowa PN-EN 25813:1997","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Dissolved oxygen concentration Range: (0,2 – 20,0) mg/l Titrimetric method PN-EN 25813:1997","search_zh":"水 废水 PN-EN 25813:1997","test_object_zh":"水 废水"},{"_id":"6a5a55f49af9f73f3825190c","lab_id":"69ad52a3de79e566650fb658","country":"PL","accr_number":"AB 1237","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie azotu amonowego Zakres: (0,05 – 2,0) mg/l Metoda spektrofotometryczna","methodology_en":"Ammonium nitrogen concentration Range: (0,05 – 2,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego Zakres: (0,05 – 2,0) mg/l Metoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie azotu amonowego Zakres: (0,05 – 2,0) mg/l Metoda spektrofotometryczna PN-ISO 7150-1:2002 Woda Scieki Stezenie azotu amonowego Zakres: (0,05 – 2,0) mg/l Metoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Ammonium nitrogen concentration Range: (0,05 – 2,0) mg/l Spectrophotometric method PN-ISO 7150-1:2002","search_zh":"水 废水 PN-ISO 7150-1:2002","test_object_zh":"水 废水"},{"_id":"6a5a55f49af9f73f3825190d","lab_id":"69ad52a3de79e566650fb658","country":"PL","accr_number":"AB 1237","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (1 – 6000) mg/l O 2 Metoda miareczkowa","methodology_en":"Biochemical oxygen demand - BOD 5 Range: (1 – 6000) mg/l O 2 Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (1 – 6000) mg/l O 2 Metoda miareczkowa","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (1 – 6000) mg/l O 2 Metoda miareczkowa PN-EN ISO 5815-1:2019-12 Woda Scieki Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (1 – 6000) mg/l O 2 Metoda miareczkowa PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Biochemical oxygen demand - BOD 5 Range: (1 – 6000) mg/l O 2 Titrimetric method PN-EN ISO 5815-1:2019-12","search_zh":"水 废水 PN-EN ISO 5815-1:2019-12","test_object_zh":"水 废水"},{"_id":"6a5a55f49af9f73f3825190e","lab_id":"69ad52a3de79e566650fb658","country":"PL","accr_number":"AB 1237","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie chlorków Zakres: (5 – 400) mg/l Metoda miareczkowa","methodology_en":"Chloride concentration Range: (5 – 400) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chlorków Zakres: (5 – 400) mg/l Metoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie chlorków Zakres: (5 – 400) mg/l Metoda miareczkowa PN-ISO 9297:1994 Woda Scieki Stezenie chlorkow Zakres: (5 – 400) mg/l Metoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Chloride concentration Range: (5 – 400) mg/l Titrimetric method PN-ISO 9297:1994","search_zh":"水 废水 氯化物浓度 范围：(5 – 400) mg/l 滴定法 PN-ISO 9297:1994","test_object_zh":"水 废水","methodology_zh":"氯化物浓度 范围：(5 – 400) mg/l 滴定法"},{"_id":"6a5a55f49af9f73f3825190f","lab_id":"69ad52a3de79e566650fb658","country":"PL","accr_number":"AB 1237","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr Zakres: (30 – 700) mg/l O 2 Metoda miareczkowa","methodology_en":"Chemical oxygen demand - COD-Cr Range: (30 – 700) mg/l O 2 Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr Zakres: (30 – 700) mg/l O 2 Metoda miareczkowa","reference":"PN-ISO 6060:2006","norm_bases":["PN-ISO 6060:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr Zakres: (30 – 700) mg/l O 2 Metoda miareczkowa PN-ISO 6060:2006 Woda Scieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr Zakres: (30 – 700) mg/l O 2 Metoda miareczkowa PN-ISO 6060:2006","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Chemical oxygen demand - COD-Cr Range: (30 – 700) mg/l O 2 Titrimetric method PN-ISO 6060:2006","search_zh":"水 废水 PN-ISO 6060:2006","test_object_zh":"水 废水"},{"_id":"6a5a55f49af9f73f38251910","lab_id":"69ad52a3de79e566650fb658","country":"PL","accr_number":"AB 1237","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie fosforu fosforanowego i fosforu ogólnego Zakres: (0,01 – 1,0) mg/l P PO4 (0,05 – 7,0) mg/l P og. Metoda spektrofotometryczna","methodology_en":"Phosphate phosphorus and total phosphorus concentration Range: (0,01 – 1,0) mg/l P PO4 (0,05 – 7,0) mg/l P total Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie fosforu fosforanowego i fosforu ogólnego Zakres: (0,01 – 1,0) mg/l P PO4 (0,05 – 7,0) mg/l P og. Metoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie fosforu fosforanowego i fosforu ogólnego Zakres: (0,01 – 1,0) mg/l P PO4 (0,05 – 7,0) mg/l P og. Metoda spektrofotometryczna PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010 Woda Scieki Stezenie fosforu fosforanowego i fosforu ogolnego Zakres: (0,01 – 1,0) mg/l P PO4 (0,05 – 7,0) mg/l P og. Metoda spektrofotometryczna PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Phosphate phosphorus and total phosphorus concentration Range: (0,01 – 1,0) mg/l P PO4 (0,05 – 7,0) mg/l P total Spectrophotometric method PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010","search_zh":"水 废水 PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010","test_object_zh":"水 废水"},{"_id":"6a5a55f49af9f73f38251911","lab_id":"69ad52a3de79e566650fb658","country":"PL","accr_number":"AB 1237","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Zawiesiny ogólne Zakres: (2,0 – 2000) mg/l Metoda wagowa","methodology_en":"Total suspended solids (TSS) Range: (2,0 – 2000) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawiesiny ogólne Zakres: (2,0 – 2000) mg/l Metoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Zawiesiny ogólne Zakres: (2,0 – 2000) mg/l Metoda wagowa PN-EN 872:2007+Ap1:2007 Woda Scieki Zawiesiny ogolne Zakres: (2,0 – 2000) mg/l Metoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Total suspended solids (TSS) Range: (2,0 – 2000) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007","search_zh":"水 废水 总悬浮物 范围：(2,0 – 2000) mg/l 重量法 PN-EN 872:2007+Ap1:2007","test_object_zh":"水 废水","methodology_zh":"总悬浮物 范围：(2,0 – 2000) mg/l 重量法"},{"_id":"6a5a55f49af9f73f38251912","lab_id":"69ad52a3de79e566650fb658","country":"PL","accr_number":"AB 1237","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"pH Zakres: 2,0 – 12,0 Metoda potencjometryczna","methodology_en":"pH Range: 2,0 – 12,0 Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH Zakres: 2,0 – 12,0 Metoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki pH Zakres: 2,0 – 12,0 Metoda potencjometryczna PN-EN ISO 10523:2012 Woda Scieki pH Zakres: 2,0 – 12,0 Metoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater pH Range: 2,0 – 12,0 Potentiometric method PN-EN ISO 10523:2012","search_zh":"水 废水 pH 范围：2,0 – 12,0 电位法 PN-EN ISO 10523:2012","test_object_zh":"水 废水","methodology_zh":"pH 范围：2,0 – 12,0 电位法"},{"_id":"6a5a55f49af9f73f38251913","lab_id":"69ad52a3de79e566650fb658","country":"PL","accr_number":"AB 1237","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Przewodność elektryczna właściwa Zakres: (100 – 3000) µS/cm Metoda konduktometryczna","methodology_en":"Electrical conductivity Range: (100 – 3000) µS/cm Conductometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa Zakres: (100 – 3000) µS/cm Metoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Przewodność elektryczna właściwa Zakres: (100 – 3000) µS/cm Metoda konduktometryczna PN-EN 27888:1999 Woda Scieki Przewodnosc elektryczna wlasciwa Zakres: (100 – 3000) µS/cm Metoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Electrical conductivity Range: (100 – 3000) µS/cm Conductometric method PN-EN 27888:1999","search_zh":"水 废水 电导率 范围：(100 – 3000) µS/cm 电导法 PN-EN 27888:1999","test_object_zh":"水 废水","methodology_zh":"电导率 范围：(100 – 3000) µS/cm 电导法"},{"_id":"6a5a55f49af9f73f38251914","lab_id":"69ad52a3de79e566650fb658","country":"PL","accr_number":"AB 1237","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie azotu azotanowego Zakres: (0,05 – 20,0) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrate nitrogen concentration Range: (0,05 – 20,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu azotanowego Zakres: (0,05 – 20,0) mg/l Metoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie azotu azotanowego Zakres: (0,05 – 20,0) mg/l Metoda spektrofotometryczna PN-82/C-04576.08 Woda Scieki Stezenie azotu azotanowego Zakres: (0,05 – 20,0) mg/l Metoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Nitrate nitrogen concentration Range: (0,05 – 20,0) mg/l Spectrophotometric method PN-82/C-04576.08","search_zh":"水 废水 PN-82/C-04576.08","test_object_zh":"水 废水"},{"_id":"6a5a55f49af9f73f38251915","lab_id":"69ad52a3de79e566650fb658","country":"PL","accr_number":"AB 1237","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie azotu azotynowego Zakres: (0,002 – 0,25) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrite nitrogen concentration Range: (0,002 – 0,25) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego Zakres: (0,002 – 0,25) mg/l Metoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie azotu azotynowego Zakres: (0,002 – 0,25) mg/l Metoda spektrofotometryczna PN-EN 26777:1999 Woda Scieki Stezenie azotu azotynowego Zakres: (0,002 – 0,25) mg/l Metoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Nitrite nitrogen concentration Range: (0,002 – 0,25) mg/l Spectrophotometric method PN-EN 26777:1999","search_zh":"水 废水 PN-EN 26777:1999","test_object_zh":"水 废水"},{"_id":"6a5a55f49af9f73f38251916","lab_id":"69ad52a3de79e566650fb658","country":"PL","accr_number":"AB 1237","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie siarczanów Zakres: (0,5 – 50,0) mg/l Metoda turbidymetryczna","methodology_en":"Sulphate concentration Range: (0,5 – 50,0) mg/l Turbidimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie siarczanów Zakres: (0,5 – 50,0) mg/l Metoda turbidymetryczna","reference":"PN-79/C-04566.10","norm_bases":["PN-79/C-04566.10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie siarczanów Zakres: (0,5 – 50,0) mg/l Metoda turbidymetryczna PN-79/C-04566.10 Woda Scieki Stezenie siarczanow Zakres: (0,5 – 50,0) mg/l Metoda turbidymetryczna PN-79/C-04566.10","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Sulphate concentration Range: (0,5 – 50,0) mg/l Turbidimetric method PN-79/C-04566.10","search_zh":"水 废水 PN-79/C-04566.10","test_object_zh":"水 废水"},{"_id":"6a5a55f49af9f73f38251917","lab_id":"69ad52a3de79e566650fb658","country":"PL","accr_number":"AB 1237","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie azotu ogólnego Zakres: (0,5 – 150) mg/l Metoda spektrofotometryczna","methodology_en":"Total nitrogen concentration Range: (0,5 – 150) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego Zakres: (0,5 – 150) mg/l Metoda spektrofotometryczna","reference":"PB-01/2012 wyd. I z dnia 01.08.2012 r. na podstawie testu kuwetowego Merck 1.14537.0001","norm_bases":["PB-01/2012 wyd. I z dnia 01.08.2012 r. na podstawie testu kuwetowego Merck 1.14537.0001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie azotu ogólnego Zakres: (0,5 – 150) mg/l Metoda spektrofotometryczna PB-01/2012 wyd. I z dnia 01.08.2012 r. na podstawie testu kuwetowego Merck 1.14537.0001 Woda Scieki Stezenie azotu ogolnego Zakres: (0,5 – 150) mg/l Metoda spektrofotometryczna PB-01/2012 wyd. I z dnia 01.08.2012 r. na podstawie testu kuwetowego Merck 1.14537.0001","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Total nitrogen concentration Range: (0,5 – 150) mg/l Spectrophotometric method PB-01/2012 wyd. I z dnia 01.08.2012 r. na podstawie testu kuwetowego Merck 1.14537.0001","search_zh":"水 废水 PB-01/2012 wyd. I z dnia 01.08.2012 r. na podstawie testu kuwetowego Merck 1.14537.0001","test_object_zh":"水 废水"},{"_id":"6a5a55f49af9f73f38251918","lab_id":"69ad52a3de79e566650fb658","country":"PL","accr_number":"AB 1237","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna Temperatura pobranej próbki ścieków Zakres: (0,5 – 30,0) ºC","methodology_en":"Sampling for chemical and physical testing Manual method Temperature of the wastewater sample taken Range: (0,5 – 30,0) ºC","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna Temperatura pobranej próbki ścieków Zakres: (0,5 – 30,0) ºC","reference":"PN-ISO 5667-10:2021-11 PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11 PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna Temperatura pobranej próbki ścieków Zakres: (0,5 – 30,0) ºC PN-ISO 5667-10:2021-11 PN-77/C-04584 Scieki Pobieranie probek do badan chemicznych i fizycznych Metoda manualna Temperatura pobranej probki sciekow Zakres: (0,5 – 30,0) ºC PN-ISO 5667-10:2021-11 PN-77/C-04584","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Sampling for chemical and physical testing Manual method Temperature of the wastewater sample taken Range: (0,5 – 30,0) ºC PN-ISO 5667-10:2021-11 PN-77/C-04584","search_zh":"污水 PN-ISO 5667-10:2021-11 PN-77/C-04584","test_object_zh":"污水"},{"_id":"6a5a55f49af9f73f38251919","lab_id":"69ad52a3de79e566650fb658","country":"PL","accr_number":"AB 1237","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody Zakres: (0,5 – 30,0) ºC","methodology_en":"Sampling for chemical and physical testing Temperature of the water sample taken Range: (0,5 – 30,0) ºC","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody Zakres: (0,5 – 30,0) ºC","reference":"PN-ISO 5667-4:2017-10 PN-ISO 5667-5:2017-10 PN-EN ISO 5667-6:2016-12 PN-77/C-04584","norm_bases":["PN-ISO 5667-4:2017-10 PN-ISO 5667-5:2017-10 PN-EN ISO 5667-6:2016-12 PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody Zakres: (0,5 – 30,0) ºC PN-ISO 5667-4:2017-10 PN-ISO 5667-5:2017-10 PN-EN ISO 5667-6:2016-12 PN-77/C-04584 Woda Pobieranie probek do badan chemicznych i fizycznych Temperatura pobranej probki wody Zakres: (0,5 – 30,0) ºC PN-ISO 5667-4:2017-10 PN-ISO 5667-5:2017-10 PN-EN ISO 5667-6:2016-12 PN-77/C-04584","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Sampling for chemical and physical testing Temperature of the water sample taken Range: (0,5 – 30,0) ºC PN-ISO 5667-4:2017-10 PN-ISO 5667-5:2017-10 PN-EN ISO 5667-6:2016-12 PN-77/C-04584","search_zh":"水 PN-ISO 5667-4:2017-10 PN-ISO 5667-5:2017-10 PN-EN ISO 5667-6:2016-12 PN-77/C-04584","test_object_zh":"水"},{"_id":"6a5a55f49af9f73f3825191a","lab_id":"69ad52a3de79e566650fb658","country":"PL","accr_number":"AB 1237","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Mętność Zakres: (0,10 – 10) NTU Metoda nefelometryczna","methodology_en":"Turbidity Range: (0,10 – 10) NTU Nephelometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Mętność Zakres: (0,10 – 10) NTU Metoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Mętność Zakres: (0,10 – 10) NTU Metoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda Metnosc Zakres: (0,10 – 10) NTU Metoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Turbidity Range: (0,10 – 10) NTU Nephelometric method PN-EN ISO 7027-1:2016-09","search_zh":"水 PN-EN ISO 7027-1:2016-09","test_object_zh":"水"},{"_id":"6a5a55f49af9f73f3825191b","lab_id":"69ad52a3de79e566650fb658","country":"PL","accr_number":"AB 1237","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Barwa Zakres: (5 – 25) mg/l Pt Metoda spektrofotometryczna","methodology_en":"Colour Range: (5 – 25) mg/l Pt Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Barwa Zakres: (5 – 25) mg/l Pt Metoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 p. 6 +Ap1:2015","norm_bases":["PN-EN ISO 7887:2012 p. 6 +Ap1:2015"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Barwa Zakres: (5 – 25) mg/l Pt Metoda spektrofotometryczna PN-EN ISO 7887:2012 p. 6 +Ap1:2015 Woda Barwa Zakres: (5 – 25) mg/l Pt Metoda spektrofotometryczna PN-EN ISO 7887:2012 p. 6 +Ap1:2015","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Colour Range: (5 – 25) mg/l Pt Spectrophotometric method PN-EN ISO 7887:2012 p. 6 +Ap1:2015","search_zh":"水 PN-EN ISO 7887:2012 p. 6 +Ap1:2015","test_object_zh":"水"},{"_id":"6a5a55f49af9f73f3825191c","lab_id":"69ad52a3de79e566650fb658","country":"PL","accr_number":"AB 1237","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna) Zakres: (0,05 – 20,0) mmol/l Metoda miareczkowa","methodology_en":"Total calcium and magnesium content (total hardness) Range: (0,05 – 20,0) mmol/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna) Zakres: (0,05 – 20,0) mmol/l Metoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Sumaryczna zawartość wapnia i magnezu (twardość ogólna) Zakres: (0,05 – 20,0) mmol/l Metoda miareczkowa PN-ISO 6059:1999 Woda Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna) Zakres: (0,05 – 20,0) mmol/l Metoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Total calcium and magnesium content (total hardness) Range: (0,05 – 20,0) mmol/l Titrimetric method PN-ISO 6059:1999","search_zh":"水 PN-ISO 6059:1999","test_object_zh":"水"},{"_id":"6a5a55f49af9f73f3825191d","lab_id":"69ad52a3de79e566650fb658","country":"PL","accr_number":"AB 1237","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Indeks nadmanganianowy Zakres: (0,5 – 500) mg/l O 2 Metoda miareczkowa","methodology_en":"Permanganate index Range: (0,5 – 500) mg/l O 2 Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Indeks nadmanganianowy Zakres: (0,5 – 500) mg/l O 2 Metoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Indeks nadmanganianowy Zakres: (0,5 – 500) mg/l O 2 Metoda miareczkowa PN-EN ISO 8467:2001 Woda Indeks nadmanganianowy Zakres: (0,5 – 500) mg/l O 2 Metoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":18,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Permanganate index Range: (0,5 – 500) mg/l O 2 Titrimetric method PN-EN ISO 8467:2001","search_zh":"水 PN-EN ISO 8467:2001","test_object_zh":"水"},{"_id":"6a5a55f49af9f73f3825191e","lab_id":"69ad52a3de79e566650fb658","country":"PL","accr_number":"AB 1237","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie żelaza Zakres: (0,05 – 5,0) mg/l Metoda spektrofotometryczna","methodology_en":"Iron concentration Range: (0,05 – 5,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie żelaza Zakres: (0,05 – 5,0) mg/l Metoda spektrofotometryczna","reference":"PB-02 z dn. 15.10.2020 na podstawie testu Merck 1.14761","norm_bases":["PB-02 z dn. 15.10.2020 na podstawie testu Merck 1.14761"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie żelaza Zakres: (0,05 – 5,0) mg/l Metoda spektrofotometryczna PB-02 z dn. 15.10.2020 na podstawie testu Merck 1.14761 Woda Stezenie zelaza Zakres: (0,05 – 5,0) mg/l Metoda spektrofotometryczna PB-02 z dn. 15.10.2020 na podstawie testu Merck 1.14761","categories":["water"],"row_index":19,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Iron concentration Range: (0,05 – 5,0) mg/l Spectrophotometric method PB-02 z dn. 15.10.2020 na podstawie testu Merck 1.14761","search_zh":"水 PB-02 z dn. 15.10.2020 na podstawie testu Merck 1.14761","test_object_zh":"水"},{"_id":"6a5a55f49af9f73f3825191f","lab_id":"69ad52a3de79e566650fb658","country":"PL","accr_number":"AB 1237","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie manganu Zakres: (0,010 – 2,0) mg/l Metoda spektrofotometryczna","methodology_en":"Manganese concentration Range: (0,010 – 2,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie manganu Zakres: (0,010 – 2,0) mg/l Metoda spektrofotometryczna","reference":"PB-03 z dn. 15.10.2020 na podstawie testu Merck 1.01846","norm_bases":["PB-03 z dn. 15.10.2020 na podstawie testu Merck 1.01846"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie manganu Zakres: (0,010 – 2,0) mg/l Metoda spektrofotometryczna PB-03 z dn. 15.10.2020 na podstawie testu Merck 1.01846 Woda Stezenie manganu Zakres: (0,010 – 2,0) mg/l Metoda spektrofotometryczna PB-03 z dn. 15.10.2020 na podstawie testu Merck 1.01846","categories":["water"],"row_index":20,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Manganese concentration Range: (0,010 – 2,0) mg/l Spectrophotometric method PB-03 z dn. 15.10.2020 na podstawie testu Merck 1.01846","search_zh":"水 PB-03 z dn. 15.10.2020 na podstawie testu Merck 1.01846","test_object_zh":"水"}],"has_pdf":true}