🇵🇱 PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o. PL

PCA AB 1231 • Tarnowskie Góry, Poland • 48 methods

Water & wastewaterMicrobiology

PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o. is a laboratory accredited by PCA under number AB 1231 (Tarnowskie Góry, Poland). Its accreditation scope covers 48 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water, water intended for human consumption, Swimming pool water, Wastewater, Water, water intended for human consumption, wastewater.

At a glance

  • Accreditation number: PCA AB 1231
  • Methods in scope: 48
  • Types of test objects: 6
  • City: Tarnowskie Góry, Poland
Accreditation number
AB 1231
Accreditation body
PCA
Address
DZIAŁ LABORATORIUM, ul. Opolska 51, 42-600 Tarnowskie Góry
City
Tarnowskie Góry, Poland

What this laboratory tests (6)

Accreditation scope — test methods (48)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Water intended for human consumption Sampling for chemical and physical testing Temperature of the water sample taken Range: (1,0 – 50) °C PN-ISO 5667-5:2017-10 PN-77/C-04584
2 Water intended for human consumption Colour Range: (5 – 35) mg/l Pt Spectrophotometric method PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06
3 Water, water intended for human consumption Total iron concentration Range: (20 – 2000) µg/l Spectrophotometric method PN-ISO 6332:2001+Ap1:2016-06
4 Water, water intended for human consumption Nitrite concentration Range: (0,01 – 0,75) mg/l Spectrophotometric method PN-EN 26777:1999
5 Water, water intended for human consumption Nitrate concentration Range: (2,0 – 60) mg/l Spectrophotometric method PN-82/C-04576/08
6 Water, water intended for human consumption Ammonium ion concentration Range: (0,26 – 1,0) mg/l Spectrophotometric method PN-94/C-04576-4
7 Water, water intended for human consumption Turbidity Range: (0,10 – 100) NTU Nephelometric method PN-EN ISO 7027-1:2016-09
8 Water, water intended for human consumption Manganese concentration Range: (10 – 300) µg/l Spectrophotometric method PN-92/C-04590/02
9 Water, water intended for human consumption Total calcium and magnesium content (total hardness) Range: (10 – 700) mg/l CaCO 3 Titrimetric method PN-ISO 6059:1999
10 Water, water intended for human consumption Free chlorine concentration Range: (0,10 – 2,0) mg/l Spectrophotometric method Metoda HACH nr 8021 wydanie 1 z 04/2014
11 Water, water intended for human consumption Permanganate index Range: (0,50 – 10) mg/l O 2 Titrimetric method PN-EN ISO 8467:2001
12 Swimming pool water Free chlorine concentration Range: (0,10 – 2,0) mg/l Spectrophotometric method Metoda HACH nr 8021 wydanie 1 z 04/2014
13 Swimming pool water Total chlorine concentration Range: (0,10 – 2,0) mg/l Spectrophotometric method Metoda HACH nr 8167 wydanie 1 z 04/2014
14 Swimming pool water Combined chlorine (calculated)
15 Swimming pool water Oxidation-reduction (redox) potential ref. to an Ag/AgCl 3,5 mol/l KCl electrode Range: (100 – 1000) mV Potentiometric method PB-10 wyd.1 z dnia 18.01.2017 r.
16 Swimming pool water Turbidity Range: (0,10 – 100) NTU Nephelometric method PN-EN ISO 7027-1:2016-09
17 Swimming pool water Nitrate concentration Range: (2,0 – 60) mg/l Spectrophotometric method PN-82/C-04576/08
18 Swimming pool water pH Range: 4,0 – 10,0 Potentiometric method PN-EN ISO 10523:2012
19 Swimming pool water Permanganate index Range: (0,50 – 10) mg/l O 2 Titrimetric method PN-EN ISO 8467:2001
20 Water, water intended for human consumption, wastewater pH Range: 4,0 – 10,0 Potentiometric method PN-EN ISO 10523:2012
21 Water, water intended for human consumption, wastewater Chloride concentration Range: (5,0 – 1000) mg/l Titrimetric method PN-ISO 9297:1994
22 Water, water intended for human consumption, wastewater Electrical conductivity Range: (10 – 12880) µS/cm Conductometric method PN-EN 27888:1999
23 Water, water intended for human consumption, wastewater Sulphate (VI) concentration Range: (10 – 1000) mg/l Gravimetric method PN-ISO 9280:2002
24 Wastewater Sampling for chemical and physical testing Manual method Automatic method Temperature of the wastewater sample taken Range: (1,0 – 50) °C PN-ISO 5667-10:2021-11 PN-77/C-04584
25 Wastewater Total suspended solids (TSS) Range: (5,0 – 2000) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007
26 Wastewater Biochemical oxygen demand - BOD 5 Range: (3 – 2000) mg/l O 2 Electrochemical method PN-EN ISO 5815-1:2019-12
27 Wastewater Chemical oxygen demand - COD-Cr Range: (10 – 10000) mg/l O 2 Spectrophotometric method PN-ISO 15705:2005
28 Wastewater Kjeldahl nitrogen concentration Range: (1,0 – 500) mg/l Titrimetric method PN-EN 25663:2001
29 Wastewater Ammonium nitrogen concentration Range: (0,50 – 200) mg/l Titrimetric method PN-ISO 5664:2002
30 Wastewater Nitrate nitrogen concentration Range: (0,10 – 60) mg/l Spectrophotometric method PN-82/C-04576/08
31 Wastewater Nitrite nitrogen concentration Range: (0,050 – 6,0) mg/l Spectrophotometric method PN-EN 26777:1999
32 Wastewater Total nitrogen concentration (calculated) PN-73/C-04576/14
33 Wastewater Total phosphorus concentration Range: (0,040 – 50,0) mg/l Spectrophotometric method PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010
34 Wastewater Substances extractable with petroleum ether Range: (5,0 – 1000) mg/l Gravimetric method PB-04 wyd.4 z dnia 24.03.2025 r.
35 Water, water intended for human consumption Cation concentration Range: potassium (1,0 − 50) mg/l sodium (1,0 − 200) mg/l ammonium ion (0,050 – 2,0) mg/l calcium (1,0 − 100) mg/l magnesium (1,0 − 150) mg/l Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 14911:2002
36 Water, water intended for human consumption, wastewater Anion concentrations Range: fluorides (0,10 − 2,00) mg/l chlorides (5,0 − 1000) mg/l phosphates (0,10 – 10,0) mg/l sulfates (5,0 − 1000) mg/l nitrites (0,050 – 5,0) mg/l nitrates (0,50 – 100) mg/l Ion chromatography with conductometric detection (IC-CD) Nitrite nitrogen concentration (calculated) Nitrate nitrogen concentration (calculated) PN-EN ISO 10304-1:2009+AC:2012
37 Water, water intended for human consumption, swimming pool water Sampling for microbiological testing PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.4
38 Water, water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
39 Water, water intended for human consumption Escherichia coli bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
40 Water, water intended for human consumption Total count of microorganisms at 36ºC Plate method (pour plate) PN-EN ISO 6222:2004
41 Water, water intended for human consumption Total count of microorganisms at 22ºC Plate method (pour plate) PN-EN ISO 6222:2004
42 Water, water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
43 Water, water intended for human consumption Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009
44 Water, water intended for human consumption Count of bacteria of the genus Legionella Membrane filtration method Matrix A Procedure 5 (medium A), 7 (medium C-GVPC) PN-EN ISO 11731:2017-08 +Ap1:2019-12
45 Swimming pool water Escherichia coli bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
46 Swimming pool water Total count of microorganisms at 36ºC Plate method (pour plate) PN-EN ISO 6222:2004
47 Swimming pool water Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009
48 Swimming pool water Count of bacteria of the genus Legionella Membrane filtration method Matrix A Procedure 5 (medium A), 7 (medium C-GVPC) PN-EN ISO 11731:2017-08 +Ap1:2019-12

Reference standards (34)

Metoda HACH nr 8021 wydanie 1 z 04/2014
Metoda HACH nr 8167 wydanie 1 z 04/2014
PB-04 wyd.4 z dnia 24.03.2025 r.
PB-10 wyd.1 z dnia 18.01.2017 r.
PN-73/C-04576/14
PN-82/C-04576/08
PN-92/C-04590/02
PN-94/C-04576-4
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10304-1:2009+AC:2012
PN-EN ISO 10523:2012
PN-EN ISO 11731:2017-08 +Ap1:2019-12
PN-EN ISO 14911:2002
PN-EN ISO 16266:2009
PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.4
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06
PN-EN ISO 7899-2:2004
PN-EN ISO 8467:2001
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11 PN-77/C-04584
PN-ISO 5667-5:2017-10 PN-77/C-04584
PN-ISO 6059:1999
PN-ISO 6332:2001+Ap1:2016-06
PN-ISO 9280:2002
PN-ISO 9297:1994