🇵🇱 PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o. PL
Water & wastewaterMicrobiology
PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o. is a laboratory accredited by PCA under number AB 1231 (Tarnowskie Góry, Poland). Its accreditation scope covers 48 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water, water intended for human consumption, Swimming pool water, Wastewater, Water, water intended for human consumption, wastewater.
At a glance
- Accreditation number: PCA AB 1231
- Methods in scope: 48
- Types of test objects: 6
- City: Tarnowskie Góry, Poland
- Accreditation number
- AB 1231
- Accreditation body
- PCA
- Address
- DZIAŁ LABORATORIUM, ul. Opolska 51, 42-600 Tarnowskie Góry
- City
- Tarnowskie Góry, Poland
What this laboratory tests (6)
- Water, water intended for human consumption — 17 methods
- Swimming pool water — 12 methods
- Wastewater — 11 methods
- Water, water intended for human consumption, wastewater — 5 methods
- Water intended for human consumption — 2 methods
- Water, water intended for human consumption, swimming pool water — 1 method
Accreditation scope — test methods (48)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Water intended for human consumption | Sampling for chemical and physical testing Temperature of the water sample taken Range: (1,0 – 50) °C | PN-ISO 5667-5:2017-10 PN-77/C-04584 | ||
| 2 | Water intended for human consumption | Colour Range: (5 – 35) mg/l Pt Spectrophotometric method | PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06 | ||
| 3 | Water, water intended for human consumption | Total iron concentration Range: (20 – 2000) µg/l Spectrophotometric method | PN-ISO 6332:2001+Ap1:2016-06 | ||
| 4 | Water, water intended for human consumption | Nitrite concentration Range: (0,01 – 0,75) mg/l Spectrophotometric method | PN-EN 26777:1999 | ||
| 5 | Water, water intended for human consumption | Nitrate concentration Range: (2,0 – 60) mg/l Spectrophotometric method | PN-82/C-04576/08 | ||
| 6 | Water, water intended for human consumption | Ammonium ion concentration Range: (0,26 – 1,0) mg/l Spectrophotometric method | PN-94/C-04576-4 | ||
| 7 | Water, water intended for human consumption | Turbidity Range: (0,10 – 100) NTU Nephelometric method | PN-EN ISO 7027-1:2016-09 | ||
| 8 | Water, water intended for human consumption | Manganese concentration Range: (10 – 300) µg/l Spectrophotometric method | PN-92/C-04590/02 | ||
| 9 | Water, water intended for human consumption | Total calcium and magnesium content (total hardness) Range: (10 – 700) mg/l CaCO 3 Titrimetric method | PN-ISO 6059:1999 | ||
| 10 | Water, water intended for human consumption | Free chlorine concentration Range: (0,10 – 2,0) mg/l Spectrophotometric method | Metoda HACH nr 8021 wydanie 1 z 04/2014 | ||
| 11 | Water, water intended for human consumption | Permanganate index Range: (0,50 – 10) mg/l O 2 Titrimetric method | PN-EN ISO 8467:2001 | ||
| 12 | Swimming pool water | Free chlorine concentration Range: (0,10 – 2,0) mg/l Spectrophotometric method | Metoda HACH nr 8021 wydanie 1 z 04/2014 | ||
| 13 | Swimming pool water | Total chlorine concentration Range: (0,10 – 2,0) mg/l Spectrophotometric method | Metoda HACH nr 8167 wydanie 1 z 04/2014 | ||
| 14 | Swimming pool water | Combined chlorine (calculated) | |||
| 15 | Swimming pool water | Oxidation-reduction (redox) potential ref. to an Ag/AgCl 3,5 mol/l KCl electrode Range: (100 – 1000) mV Potentiometric method | PB-10 wyd.1 z dnia 18.01.2017 r. | ||
| 16 | Swimming pool water | Turbidity Range: (0,10 – 100) NTU Nephelometric method | PN-EN ISO 7027-1:2016-09 | ||
| 17 | Swimming pool water | Nitrate concentration Range: (2,0 – 60) mg/l Spectrophotometric method | PN-82/C-04576/08 | ||
| 18 | Swimming pool water | pH Range: 4,0 – 10,0 Potentiometric method | PN-EN ISO 10523:2012 | ||
| 19 | Swimming pool water | Permanganate index Range: (0,50 – 10) mg/l O 2 Titrimetric method | PN-EN ISO 8467:2001 | ||
| 20 | Water, water intended for human consumption, wastewater | pH Range: 4,0 – 10,0 Potentiometric method | PN-EN ISO 10523:2012 | ||
| 21 | Water, water intended for human consumption, wastewater | Chloride concentration Range: (5,0 – 1000) mg/l Titrimetric method | PN-ISO 9297:1994 | ||
| 22 | Water, water intended for human consumption, wastewater | Electrical conductivity Range: (10 – 12880) µS/cm Conductometric method | PN-EN 27888:1999 | ||
| 23 | Water, water intended for human consumption, wastewater | Sulphate (VI) concentration Range: (10 – 1000) mg/l Gravimetric method | PN-ISO 9280:2002 | ||
| 24 | Wastewater | Sampling for chemical and physical testing Manual method Automatic method Temperature of the wastewater sample taken Range: (1,0 – 50) °C | PN-ISO 5667-10:2021-11 PN-77/C-04584 | ||
| 25 | Wastewater | Total suspended solids (TSS) Range: (5,0 – 2000) mg/l Gravimetric method | PN-EN 872:2007+Ap1:2007 | ||
| 26 | Wastewater | Biochemical oxygen demand - BOD 5 Range: (3 – 2000) mg/l O 2 Electrochemical method | PN-EN ISO 5815-1:2019-12 | ||
| 27 | Wastewater | Chemical oxygen demand - COD-Cr Range: (10 – 10000) mg/l O 2 Spectrophotometric method | PN-ISO 15705:2005 | ||
| 28 | Wastewater | Kjeldahl nitrogen concentration Range: (1,0 – 500) mg/l Titrimetric method | PN-EN 25663:2001 | ||
| 29 | Wastewater | Ammonium nitrogen concentration Range: (0,50 – 200) mg/l Titrimetric method | PN-ISO 5664:2002 | ||
| 30 | Wastewater | Nitrate nitrogen concentration Range: (0,10 – 60) mg/l Spectrophotometric method | PN-82/C-04576/08 | ||
| 31 | Wastewater | Nitrite nitrogen concentration Range: (0,050 – 6,0) mg/l Spectrophotometric method | PN-EN 26777:1999 | ||
| 32 | Wastewater | Total nitrogen concentration (calculated) | PN-73/C-04576/14 | ||
| 33 | Wastewater | Total phosphorus concentration Range: (0,040 – 50,0) mg/l Spectrophotometric method | PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010 | ||
| 34 | Wastewater | Substances extractable with petroleum ether Range: (5,0 – 1000) mg/l Gravimetric method | PB-04 wyd.4 z dnia 24.03.2025 r. | ||
| 35 | Water, water intended for human consumption | Cation concentration Range: potassium (1,0 − 50) mg/l sodium (1,0 − 200) mg/l ammonium ion (0,050 – 2,0) mg/l calcium (1,0 − 100) mg/l magnesium (1,0 − 150) mg/l Ion chromatography with conductometric detection (IC-CD) | PN-EN ISO 14911:2002 | ||
| 36 | Water, water intended for human consumption, wastewater | Anion concentrations Range: fluorides (0,10 − 2,00) mg/l chlorides (5,0 − 1000) mg/l phosphates (0,10 – 10,0) mg/l sulfates (5,0 − 1000) mg/l nitrites (0,050 – 5,0) mg/l nitrates (0,50 – 100) mg/l Ion chromatography with conductometric detection (IC-CD) Nitrite nitrogen concentration (calculated) Nitrate nitrogen concentration (calculated) | PN-EN ISO 10304-1:2009+AC:2012 | ||
| 37 | Water, water intended for human consumption, swimming pool water | Sampling for microbiological testing | PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.4 | ||
| 38 | Water, water intended for human consumption | Coliform bacteria count Membrane filtration method | PN-EN ISO 9308-1:2014-12 +A1:2017-04 | ||
| 39 | Water, water intended for human consumption | Escherichia coli bacteria count Membrane filtration method | PN-EN ISO 9308-1:2014-12 +A1:2017-04 | ||
| 40 | Water, water intended for human consumption | Total count of microorganisms at 36ºC Plate method (pour plate) | PN-EN ISO 6222:2004 | ||
| 41 | Water, water intended for human consumption | Total count of microorganisms at 22ºC Plate method (pour plate) | PN-EN ISO 6222:2004 | ||
| 42 | Water, water intended for human consumption | Intestinal enterococci count Membrane filtration method | PN-EN ISO 7899-2:2004 | ||
| 43 | Water, water intended for human consumption | Pseudomonas aeruginosa count Membrane filtration method | PN-EN ISO 16266:2009 | ||
| 44 | Water, water intended for human consumption | Count of bacteria of the genus Legionella Membrane filtration method Matrix A Procedure 5 (medium A), 7 (medium C-GVPC) | PN-EN ISO 11731:2017-08 +Ap1:2019-12 | ||
| 45 | Swimming pool water | Escherichia coli bacteria count Membrane filtration method | PN-EN ISO 9308-1:2014-12 +A1:2017-04 | ||
| 46 | Swimming pool water | Total count of microorganisms at 36ºC Plate method (pour plate) | PN-EN ISO 6222:2004 | ||
| 47 | Swimming pool water | Pseudomonas aeruginosa count Membrane filtration method | PN-EN ISO 16266:2009 | ||
| 48 | Swimming pool water | Count of bacteria of the genus Legionella Membrane filtration method Matrix A Procedure 5 (medium A), 7 (medium C-GVPC) | PN-EN ISO 11731:2017-08 +Ap1:2019-12 | ||
Reference standards (34)
Metoda HACH nr 8021 wydanie 1 z 04/2014
Metoda HACH nr 8167 wydanie 1 z 04/2014
PB-04 wyd.4 z dnia 24.03.2025 r.
PB-10 wyd.1 z dnia 18.01.2017 r.
PN-73/C-04576/14
PN-82/C-04576/08
PN-92/C-04590/02
PN-94/C-04576-4
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10304-1:2009+AC:2012
PN-EN ISO 10523:2012
PN-EN ISO 11731:2017-08 +Ap1:2019-12
PN-EN ISO 14911:2002
PN-EN ISO 16266:2009
PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.4
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06
PN-EN ISO 7899-2:2004
PN-EN ISO 8467:2001
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11 PN-77/C-04584
PN-ISO 5667-5:2017-10 PN-77/C-04584
PN-ISO 6059:1999
PN-ISO 6332:2001+Ap1:2016-06
PN-ISO 9280:2002
PN-ISO 9297:1994