{"lab":{"_id":"69ad52a3de79e566650fb656","accr_number":"AB 1231","country":"PL","accr_body":"PCA","address":"DZIAŁ LABORATORIUM, ul. Opolska 51, 42-600 Tarnowskie Góry","categories":["water","microbiology"],"city":"Tarnowskie Góry","imported_at":"2026-03-08T10:42:43.265Z","methods_count":48,"name":"PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1231.pdf"],"scope_summary":"","search_text":"przedsiębiorstwo wodociągów i kanalizacji sp. z o.o. dział laboratorium, ul. opolska 51, 42-600 tarnowskie góry water other pharma electronics microbiology","status":"active","updated_at":"2026-03-08T14:50:24.768Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:24.768Z","email_confidence":"high","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%201231,plik.html","parse_date":"2026-07-17T16:19:00.278Z","parse_source":"m5-mistral-qa","fields_of_testing":[{"codes":"C/29/P; C/30/P","pl":"Badania chemiczne i pobieranie próbek wody do spożycia przez ludzi, ścieków","en":"Chemical tests and sampling of drinking water, sewage"},{"codes":"C/28","pl":"Badania chemiczne wody","en":"Chemical tests of water"},{"codes":"N/29/P; N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody do spożycia przez ludzi, ścieków","en":"Tests of physical properties and sampling of drinking water, sewage"},{"codes":"N/28","pl":"Badania właściwości fizycznych wody","en":"Tests of physical properties of water"},{"codes":"K/28/P; K/29/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody, wody do spożycia przez ludzi","en":"Microbiological tests and sampling of water, drinking water"}],"issue":{"no":"15","date":"02.09.2025"},"map_coord":[50.450287,18.843969],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":48,"microbiology":6},"category_scores":{"water":42.67,"microbiology":0.67},"has_zh":true},"methods":[{"_id":"6a5a55f49af9f73f382518db","lab_id":"69ad52a3de79e566650fb656","country":"PL","accr_number":"AB 1231","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody Zakres: (1,0 – 50) °C","methodology_en":"Sampling for chemical and physical testing Temperature of the water sample taken Range: (1,0 – 50) °C","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody Zakres: (1,0 – 50) °C","reference":"PN-ISO 5667-5:2017-10 PN-77/C-04584","norm_bases":["PN-ISO 5667-5:2017-10 PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody Zakres: (1,0 – 50) °C PN-ISO 5667-5:2017-10 PN-77/C-04584 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych Temperatura pobranej probki wody Zakres: (1,0 – 50) °C PN-ISO 5667-5:2017-10 PN-77/C-04584","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Sampling for chemical and physical testing Temperature of the water sample taken Range: (1,0 – 50) °C PN-ISO 5667-5:2017-10 PN-77/C-04584","search_zh":"生活饮用水 PN-ISO 5667-5:2017-10 PN-77/C-04584","test_object_zh":"生活饮用水"},{"_id":"6a5a55f49af9f73f382518dc","lab_id":"69ad52a3de79e566650fb656","country":"PL","accr_number":"AB 1231","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Barwa Zakres: (5 – 35) mg/l Pt Metoda spektrofotometryczna","methodology_en":"Colour Range: (5 – 35) mg/l Pt Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Barwa Zakres: (5 – 35) mg/l Pt Metoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06","norm_bases":["PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Barwa Zakres: (5 – 35) mg/l Pt Metoda spektrofotometryczna PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06 Woda do spozycia przez ludzi Barwa Zakres: (5 – 35) mg/l Pt Metoda spektrofotometryczna PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Colour Range: (5 – 35) mg/l Pt Spectrophotometric method PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06","search_zh":"生活饮用水 PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06","test_object_zh":"生活饮用水"},{"_id":"6a5a55f49af9f73f382518dd","lab_id":"69ad52a3de79e566650fb656","country":"PL","accr_number":"AB 1231","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie żelaza ogólnego Zakres: (20 – 2000) µg/l Metoda spektrofotometryczna","methodology_en":"Total iron concentration Range: (20 – 2000) µg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie żelaza ogólnego Zakres: (20 – 2000) µg/l Metoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie żelaza ogólnego Zakres: (20 – 2000) µg/l Metoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 Woda, woda do spozycia przez ludzi Stezenie zelaza ogolnego Zakres: (20 – 2000) µg/l Metoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Total iron concentration Range: (20 – 2000) µg/l Spectrophotometric method PN-ISO 6332:2001+Ap1:2016-06","search_zh":"水、生活饮用水 PN-ISO 6332:2001+Ap1:2016-06","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55f49af9f73f382518de","lab_id":"69ad52a3de79e566650fb656","country":"PL","accr_number":"AB 1231","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie azotynów Zakres: (0,01 – 0,75) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrite concentration Range: (0,01 – 0,75) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotynów Zakres: (0,01 – 0,75) mg/l Metoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie azotynów Zakres: (0,01 – 0,75) mg/l Metoda spektrofotometryczna PN-EN 26777:1999 Woda, woda do spozycia przez ludzi Stezenie azotynow Zakres: (0,01 – 0,75) mg/l Metoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Nitrite concentration Range: (0,01 – 0,75) mg/l Spectrophotometric method PN-EN 26777:1999","search_zh":"水、生活饮用水 PN-EN 26777:1999","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55f49af9f73f382518df","lab_id":"69ad52a3de79e566650fb656","country":"PL","accr_number":"AB 1231","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie azotanów Zakres: (2,0 – 60) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrate concentration Range: (2,0 – 60) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotanów Zakres: (2,0 – 60) mg/l Metoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie azotanów Zakres: (2,0 – 60) mg/l Metoda spektrofotometryczna PN-82/C-04576/08 Woda, woda do spozycia przez ludzi Stezenie azotanow Zakres: (2,0 – 60) mg/l Metoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Nitrate concentration Range: (2,0 – 60) mg/l Spectrophotometric method PN-82/C-04576/08","search_zh":"水、生活饮用水 PN-82/C-04576/08","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55f49af9f73f382518e0","lab_id":"69ad52a3de79e566650fb656","country":"PL","accr_number":"AB 1231","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie jonu amonowego Zakres: (0,26 – 1,0) mg/l Metoda spektrofotometryczna","methodology_en":"Ammonium ion concentration Range: (0,26 – 1,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie jonu amonowego Zakres: (0,26 – 1,0) mg/l Metoda spektrofotometryczna","reference":"PN-94/C-04576-4","norm_bases":["PN-94/C-04576-4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie jonu amonowego Zakres: (0,26 – 1,0) mg/l Metoda spektrofotometryczna PN-94/C-04576-4 Woda, woda do spozycia przez ludzi Stezenie jonu amonowego Zakres: (0,26 – 1,0) mg/l Metoda spektrofotometryczna PN-94/C-04576-4","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Ammonium ion concentration Range: (0,26 – 1,0) mg/l Spectrophotometric method PN-94/C-04576-4","search_zh":"水、生活饮用水 PN-94/C-04576-4","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55f49af9f73f382518e1","lab_id":"69ad52a3de79e566650fb656","country":"PL","accr_number":"AB 1231","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Mętność Zakres: (0,10 – 100) NTU Metoda nefelometryczna","methodology_en":"Turbidity Range: (0,10 – 100) NTU Nephelometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Mętność Zakres: (0,10 – 100) NTU Metoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Mętność Zakres: (0,10 – 100) NTU Metoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda, woda do spozycia przez ludzi Metnosc Zakres: (0,10 – 100) NTU Metoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Turbidity Range: (0,10 – 100) NTU Nephelometric method PN-EN ISO 7027-1:2016-09","search_zh":"水、生活饮用水 浊度 范围：(0,10 – 100) NTU 散射法 PN-EN ISO 7027-1:2016-09","test_object_zh":"水、生活饮用水","methodology_zh":"浊度 范围：(0,10 – 100) NTU 散射法"},{"_id":"6a5a55f49af9f73f382518e2","lab_id":"69ad52a3de79e566650fb656","country":"PL","accr_number":"AB 1231","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie manganu Zakres: (10 – 300) µg/l Metoda spektrofotometryczna","methodology_en":"Manganese concentration Range: (10 – 300) µg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie manganu Zakres: (10 – 300) µg/l Metoda spektrofotometryczna","reference":"PN-92/C-04590/02","norm_bases":["PN-92/C-04590/02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie manganu Zakres: (10 – 300) µg/l Metoda spektrofotometryczna PN-92/C-04590/02 Woda, woda do spozycia przez ludzi Stezenie manganu Zakres: (10 – 300) µg/l Metoda spektrofotometryczna PN-92/C-04590/02","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Manganese concentration Range: (10 – 300) µg/l Spectrophotometric method PN-92/C-04590/02","search_zh":"水、生活饮用水 PN-92/C-04590/02","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55f49af9f73f382518e3","lab_id":"69ad52a3de79e566650fb656","country":"PL","accr_number":"AB 1231","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna) Zakres: (10 – 700) mg/l CaCO 3 Metoda miareczkowa","methodology_en":"Total calcium and magnesium content (total hardness) Range: (10 – 700) mg/l CaCO 3 Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna) Zakres: (10 – 700) mg/l CaCO 3 Metoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Sumaryczna zawartość wapnia i magnezu (twardość ogólna) Zakres: (10 – 700) mg/l CaCO 3 Metoda miareczkowa PN-ISO 6059:1999 Woda, woda do spozycia przez ludzi Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna) Zakres: (10 – 700) mg/l CaCO 3 Metoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Total calcium and magnesium content (total hardness) Range: (10 – 700) mg/l CaCO 3 Titrimetric method PN-ISO 6059:1999","search_zh":"水、生活饮用水 PN-ISO 6059:1999","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55f49af9f73f382518e4","lab_id":"69ad52a3de79e566650fb656","country":"PL","accr_number":"AB 1231","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie wolnego chloru Zakres: (0,10 – 2,0) mg/l Metoda spektrofotometryczna","methodology_en":"Free chlorine concentration Range: (0,10 – 2,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie wolnego chloru Zakres: (0,10 – 2,0) mg/l Metoda spektrofotometryczna","reference":"Metoda HACH nr 8021 wydanie 1 z 04/2014","norm_bases":["Metoda HACH nr 8021 wydanie 1 z 04/2014"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie wolnego chloru Zakres: (0,10 – 2,0) mg/l Metoda spektrofotometryczna Metoda HACH nr 8021 wydanie 1 z 04/2014 Woda, woda do spozycia przez ludzi Stezenie wolnego chloru Zakres: (0,10 – 2,0) mg/l Metoda spektrofotometryczna Metoda HACH nr 8021 wydanie 1 z 04/2014","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Free chlorine concentration Range: (0,10 – 2,0) mg/l Spectrophotometric method Metoda HACH nr 8021 wydanie 1 z 04/2014","search_zh":"水、生活饮用水 Metoda HACH nr 8021 wydanie 1 z 04/2014","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55f49af9f73f382518e5","lab_id":"69ad52a3de79e566650fb656","country":"PL","accr_number":"AB 1231","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Indeks nadmanganianowy Zakres: (0,50 – 10) mg/l O 2 Metoda miareczkowa","methodology_en":"Permanganate index Range: (0,50 – 10) mg/l O 2 Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Indeks nadmanganianowy Zakres: (0,50 – 10) mg/l O 2 Metoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Indeks nadmanganianowy Zakres: (0,50 – 10) mg/l O 2 Metoda miareczkowa PN-EN ISO 8467:2001 Woda, woda do spozycia przez ludzi Indeks nadmanganianowy Zakres: (0,50 – 10) mg/l O 2 Metoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Permanganate index Range: (0,50 – 10) mg/l O 2 Titrimetric method PN-EN ISO 8467:2001","search_zh":"水、生活饮用水 高锰酸盐指数 范围：(0,50 – 10) mg/l O2 滴定法 PN-EN ISO 8467:2001","test_object_zh":"水、生活饮用水","methodology_zh":"高锰酸盐指数 范围：(0,50 – 10) mg/l O2 滴定法"},{"_id":"6a5a55f49af9f73f382518e6","lab_id":"69ad52a3de79e566650fb656","country":"PL","accr_number":"AB 1231","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Stężenie wolnego chloru Zakres: (0,10 – 2,0) mg/l Metoda spektrofotometryczna","methodology_en":"Free chlorine concentration Range: (0,10 – 2,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie wolnego chloru Zakres: (0,10 – 2,0) mg/l Metoda spektrofotometryczna","reference":"Metoda HACH nr 8021 wydanie 1 z 04/2014","norm_bases":["Metoda HACH nr 8021 wydanie 1 z 04/2014"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Stężenie wolnego chloru Zakres: (0,10 – 2,0) mg/l Metoda spektrofotometryczna Metoda HACH nr 8021 wydanie 1 z 04/2014 Woda na plywalniach Stezenie wolnego chloru Zakres: (0,10 – 2,0) mg/l Metoda spektrofotometryczna Metoda HACH nr 8021 wydanie 1 z 04/2014","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Swimming pool water Free chlorine concentration Range: (0,10 – 2,0) mg/l Spectrophotometric method Metoda HACH nr 8021 wydanie 1 z 04/2014","search_zh":"游泳池水 Metoda HACH nr 8021 wydanie 1 z 04/2014","test_object_zh":"游泳池水"},{"_id":"6a5a55f49af9f73f382518e7","lab_id":"69ad52a3de79e566650fb656","country":"PL","accr_number":"AB 1231","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Stężenie chloru ogólnego Zakres: (0,10 – 2,0) mg/l Metoda spektrofotometryczna","methodology_en":"Total chlorine concentration Range: (0,10 – 2,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chloru ogólnego Zakres: (0,10 – 2,0) mg/l Metoda spektrofotometryczna","reference":"Metoda HACH nr 8167 wydanie 1 z 04/2014","norm_bases":["Metoda HACH nr 8167 wydanie 1 z 04/2014"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Stężenie chloru ogólnego Zakres: (0,10 – 2,0) mg/l Metoda spektrofotometryczna Metoda HACH nr 8167 wydanie 1 z 04/2014 Woda na plywalniach Stezenie chloru ogolnego Zakres: (0,10 – 2,0) mg/l Metoda spektrofotometryczna Metoda HACH nr 8167 wydanie 1 z 04/2014","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Swimming pool water Total chlorine concentration Range: (0,10 – 2,0) mg/l Spectrophotometric method Metoda HACH nr 8167 wydanie 1 z 04/2014","search_zh":"游泳池水 Metoda HACH nr 8167 wydanie 1 z 04/2014","test_object_zh":"游泳池水"},{"_id":"6a5a55f49af9f73f382518e8","lab_id":"69ad52a3de79e566650fb656","country":"PL","accr_number":"AB 1231","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Chlor związany (z obliczeń)","methodology_en":"Combined chlorine (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Chlor związany (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Chlor związany (z obliczeń) Woda na plywalniach Chlor zwiazany (z obliczen)","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Swimming pool water Combined chlorine (calculated)","search_zh":"游泳池水 化合氯（由计算得出）","test_object_zh":"游泳池水","methodology_zh":"化合氯（由计算得出）"},{"_id":"6a5a55f49af9f73f382518e9","lab_id":"69ad52a3de79e566650fb656","country":"PL","accr_number":"AB 1231","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Potencjał utleniająco-redukujący (redoks) wzgl. elektrody Ag/AgCl 3,5 mol/l KCl Zakres: (100 – 1000) mV Metoda potencjometryczna","methodology_en":"Oxidation-reduction (redox) potential ref. to an Ag/AgCl 3,5 mol/l KCl electrode Range: (100 – 1000) mV Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Potencjał utleniająco-redukujący (redoks) wzgl. elektrody Ag/AgCl 3,5 mol/l KCl Zakres: (100 – 1000) mV Metoda potencjometryczna","reference":"PB-10 wyd.1 z dnia 18.01.2017 r.","norm_bases":["PB-10 wyd.1 z dnia 18.01.2017 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Potencjał utleniająco-redukujący (redoks) wzgl. elektrody Ag/AgCl 3,5 mol/l KCl Zakres: (100 – 1000) mV Metoda potencjometryczna PB-10 wyd.1 z dnia 18.01.2017 r. Woda na plywalniach Potencjal utleniajaco-redukujacy (redoks) wzgl. elektrody Ag/AgCl 3,5 mol/l KCl Zakres: (100 – 1000) mV Metoda potencjometryczna PB-10 wyd.1 z dnia 18.01.2017 r.","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Swimming pool water Oxidation-reduction (redox) potential ref. to an Ag/AgCl 3,5 mol/l KCl electrode Range: (100 – 1000) mV Potentiometric method PB-10 wyd.1 z dnia 18.01.2017 r.","search_zh":"游泳池水 PB-10 wyd.1 z dnia 18.01.2017 r.","test_object_zh":"游泳池水"},{"_id":"6a5a55f49af9f73f382518ea","lab_id":"69ad52a3de79e566650fb656","country":"PL","accr_number":"AB 1231","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Mętność Zakres: (0,10 – 100) NTU Metoda nefelometryczna","methodology_en":"Turbidity Range: (0,10 – 100) NTU Nephelometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Mętność Zakres: (0,10 – 100) NTU Metoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Mętność Zakres: (0,10 – 100) NTU Metoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda na plywalniach Metnosc Zakres: (0,10 – 100) NTU Metoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Swimming pool water Turbidity Range: (0,10 – 100) NTU Nephelometric method PN-EN ISO 7027-1:2016-09","search_zh":"游泳池水 浊度 范围：(0,10 – 100) NTU 散射法 PN-EN ISO 7027-1:2016-09","test_object_zh":"游泳池水","methodology_zh":"浊度 范围：(0,10 – 100) NTU 散射法"},{"_id":"6a5a55f49af9f73f382518eb","lab_id":"69ad52a3de79e566650fb656","country":"PL","accr_number":"AB 1231","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Stężenie azotanów Zakres: (2,0 – 60) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrate concentration Range: (2,0 – 60) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotanów Zakres: (2,0 – 60) mg/l Metoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Stężenie azotanów Zakres: (2,0 – 60) mg/l Metoda spektrofotometryczna PN-82/C-04576/08 Woda na plywalniach Stezenie azotanow Zakres: (2,0 – 60) mg/l Metoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Swimming pool water Nitrate concentration Range: (2,0 – 60) mg/l Spectrophotometric method PN-82/C-04576/08","search_zh":"游泳池水 PN-82/C-04576/08","test_object_zh":"游泳池水"},{"_id":"6a5a55f49af9f73f382518ec","lab_id":"69ad52a3de79e566650fb656","country":"PL","accr_number":"AB 1231","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"pH Zakres: 4,0 – 10,0 Metoda potencjometryczna","methodology_en":"pH Range: 4,0 – 10,0 Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH Zakres: 4,0 – 10,0 Metoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach pH Zakres: 4,0 – 10,0 Metoda potencjometryczna PN-EN ISO 10523:2012 Woda na plywalniach pH Zakres: 4,0 – 10,0 Metoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Swimming pool water pH Range: 4,0 – 10,0 Potentiometric method PN-EN ISO 10523:2012","search_zh":"游泳池水 pH 范围：4,0 – 10,0 电位法 PN-EN ISO 10523:2012","test_object_zh":"游泳池水","methodology_zh":"pH 范围：4,0 – 10,0 电位法"},{"_id":"6a5a55f49af9f73f382518ed","lab_id":"69ad52a3de79e566650fb656","country":"PL","accr_number":"AB 1231","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Indeks nadmanganianowy Zakres: (0,50 – 10) mg/l O 2 Metoda miareczkowa","methodology_en":"Permanganate index Range: (0,50 – 10) mg/l O 2 Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Indeks nadmanganianowy Zakres: (0,50 – 10) mg/l O 2 Metoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Indeks nadmanganianowy Zakres: (0,50 – 10) mg/l O 2 Metoda miareczkowa PN-EN ISO 8467:2001 Woda na plywalniach Indeks nadmanganianowy Zakres: (0,50 – 10) mg/l O 2 Metoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":18,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Swimming pool water Permanganate index Range: (0,50 – 10) mg/l O 2 Titrimetric method PN-EN ISO 8467:2001","search_zh":"游泳池水 高锰酸盐指数 范围：(0,50 – 10) mg/l O2 滴定法 PN-EN ISO 8467:2001","test_object_zh":"游泳池水","methodology_zh":"高锰酸盐指数 范围：(0,50 – 10) mg/l O2 滴定法"},{"_id":"6a5a55f49af9f73f382518ee","lab_id":"69ad52a3de79e566650fb656","country":"PL","accr_number":"AB 1231","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"pH Zakres: 4,0 – 10,0 Metoda potencjometryczna","methodology_en":"pH Range: 4,0 – 10,0 Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH Zakres: 4,0 – 10,0 Metoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki pH Zakres: 4,0 – 10,0 Metoda potencjometryczna PN-EN ISO 10523:2012 Woda, woda do spozycia przez ludzi, scieki pH Zakres: 4,0 – 10,0 Metoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":19,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption, wastewater pH Range: 4,0 – 10,0 Potentiometric method PN-EN ISO 10523:2012","search_zh":"水、生活饮用水、污水 pH 范围：4,0 – 10,0 电位法 PN-EN ISO 10523:2012","test_object_zh":"水、生活饮用水、污水","methodology_zh":"pH 范围：4,0 – 10,0 电位法"},{"_id":"6a5a55f49af9f73f382518ef","lab_id":"69ad52a3de79e566650fb656","country":"PL","accr_number":"AB 1231","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Stężenie chlorków Zakres: (5,0 – 1000) mg/l Metoda miareczkowa","methodology_en":"Chloride concentration Range: (5,0 – 1000) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chlorków Zakres: (5,0 – 1000) mg/l Metoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie chlorków Zakres: (5,0 – 1000) mg/l Metoda miareczkowa PN-ISO 9297:1994 Woda, woda do spozycia przez ludzi, scieki Stezenie chlorkow Zakres: (5,0 – 1000) mg/l Metoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":20,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption, wastewater Chloride concentration Range: (5,0 – 1000) mg/l Titrimetric method PN-ISO 9297:1994","search_zh":"水、生活饮用水、污水 氯化物浓度 范围：(5,0 – 1000) mg/l 滴定法 PN-ISO 9297:1994","test_object_zh":"水、生活饮用水、污水","methodology_zh":"氯化物浓度 范围：(5,0 – 1000) mg/l 滴定法"},{"_id":"6a5a55f49af9f73f382518f0","lab_id":"69ad52a3de79e566650fb656","country":"PL","accr_number":"AB 1231","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Przewodność elektryczna właściwa Zakres: (10 – 12880) µS/cm Metoda konduktometryczna","methodology_en":"Electrical conductivity Range: (10 – 12880) µS/cm Conductometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa Zakres: (10 – 12880) µS/cm Metoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Przewodność elektryczna właściwa Zakres: (10 – 12880) µS/cm Metoda konduktometryczna PN-EN 27888:1999 Woda, woda do spozycia przez ludzi, scieki Przewodnosc elektryczna wlasciwa Zakres: (10 – 12880) µS/cm Metoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":21,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption, wastewater Electrical conductivity Range: (10 – 12880) µS/cm Conductometric method PN-EN 27888:1999","search_zh":"水、生活饮用水、污水 PN-EN 27888:1999","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5a55f49af9f73f382518f1","lab_id":"69ad52a3de79e566650fb656","country":"PL","accr_number":"AB 1231","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Stężenie siarczanów (VI) Zakres: (10 – 1000) mg/l Metoda wagowa","methodology_en":"Sulphate (VI) concentration Range: (10 – 1000) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie siarczanów (VI) Zakres: (10 – 1000) mg/l Metoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie siarczanów (VI) Zakres: (10 – 1000) mg/l Metoda wagowa PN-ISO 9280:2002 Woda, woda do spozycia przez ludzi, scieki Stezenie siarczanow (VI) Zakres: (10 – 1000) mg/l Metoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":22,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption, wastewater Sulphate (VI) concentration Range: (10 – 1000) mg/l Gravimetric method PN-ISO 9280:2002","search_zh":"水、生活饮用水、污水 PN-ISO 9280:2002","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5a55f49af9f73f382518f2","lab_id":"69ad52a3de79e566650fb656","country":"PL","accr_number":"AB 1231","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna Metoda automatyczna Temperatura pobranej próbki ścieków Zakres: (1,0 – 50) °C","methodology_en":"Sampling for chemical and physical testing Manual method Automatic method Temperature of the wastewater sample taken Range: (1,0 – 50) °C","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna Metoda automatyczna Temperatura pobranej próbki ścieków Zakres: (1,0 – 50) °C","reference":"PN-ISO 5667-10:2021-11 PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11 PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna Metoda automatyczna Temperatura pobranej próbki ścieków Zakres: (1,0 – 50) °C PN-ISO 5667-10:2021-11 PN-77/C-04584 Scieki Pobieranie probek do badan chemicznych i fizycznych Metoda manualna Metoda automatyczna Temperatura pobranej probki sciekow Zakres: (1,0 – 50) °C PN-ISO 5667-10:2021-11 PN-77/C-04584","categories":["water"],"row_index":23,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Sampling for chemical and physical testing Manual method Automatic method Temperature of the wastewater sample taken Range: (1,0 – 50) °C PN-ISO 5667-10:2021-11 PN-77/C-04584","search_zh":"污水 PN-ISO 5667-10:2021-11 PN-77/C-04584","test_object_zh":"污水"},{"_id":"6a5a55f49af9f73f382518f3","lab_id":"69ad52a3de79e566650fb656","country":"PL","accr_number":"AB 1231","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Zawiesiny ogólne Zakres: (5,0 – 2000) mg/l Metoda wagowa","methodology_en":"Total suspended solids (TSS) Range: (5,0 – 2000) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawiesiny ogólne Zakres: (5,0 – 2000) mg/l Metoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Zawiesiny ogólne Zakres: (5,0 – 2000) mg/l Metoda wagowa PN-EN 872:2007+Ap1:2007 Scieki Zawiesiny ogolne Zakres: (5,0 – 2000) mg/l Metoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":24,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Total suspended solids (TSS) Range: (5,0 – 2000) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007","methodology_zh":"总悬浮物 范围：(5,0 – 2000) mg/l 重量法","search_zh":"污水 总悬浮物 范围：(5,0 – 2000) mg/l 重量法 PN-EN 872:2007+Ap1:2007","test_object_zh":"污水"},{"_id":"6a5a55f49af9f73f382518f4","lab_id":"69ad52a3de79e566650fb656","country":"PL","accr_number":"AB 1231","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (3 – 2000) mg/l O 2 Metoda elektrochemiczna","methodology_en":"Biochemical oxygen demand - BOD 5 Range: (3 – 2000) mg/l O 2 Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (3 – 2000) mg/l O 2 Metoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (3 – 2000) mg/l O 2 Metoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Scieki Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (3 – 2000) mg/l O 2 Metoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":25,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Biochemical oxygen demand - BOD 5 Range: (3 – 2000) mg/l O 2 Electrochemical method PN-EN ISO 5815-1:2019-12","search_zh":"污水 五日生化需氧量 BZT 5 范围：(3 – 2000) mg/l O2 电化学法 PN-EN ISO 5815-1:2019-12","test_object_zh":"污水","methodology_zh":"五日生化需氧量 BZT 5 范围：(3 – 2000) mg/l O2 电化学法"},{"_id":"6a5a55f49af9f73f382518f5","lab_id":"69ad52a3de79e566650fb656","country":"PL","accr_number":"AB 1231","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr Zakres: (10 – 10000) mg/l O 2 Metoda spektrofotometryczna","methodology_en":"Chemical oxygen demand - COD-Cr Range: (10 – 10000) mg/l O 2 Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr Zakres: (10 – 10000) mg/l O 2 Metoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr Zakres: (10 – 10000) mg/l O 2 Metoda spektrofotometryczna PN-ISO 15705:2005 Scieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr Zakres: (10 – 10000) mg/l O 2 Metoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":26,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Chemical oxygen demand - COD-Cr Range: (10 – 10000) mg/l O 2 Spectrophotometric method PN-ISO 15705:2005","search_zh":"污水 PN-ISO 15705:2005","test_object_zh":"污水"},{"_id":"6a5a55f49af9f73f382518f6","lab_id":"69ad52a3de79e566650fb656","country":"PL","accr_number":"AB 1231","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu Kjeldahla Zakres: (1,0 – 500) mg/l Metoda miareczkowa","methodology_en":"Kjeldahl nitrogen concentration Range: (1,0 – 500) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla Zakres: (1,0 – 500) mg/l Metoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu Kjeldahla Zakres: (1,0 – 500) mg/l Metoda miareczkowa PN-EN 25663:2001 Scieki Stezenie azotu Kjeldahla Zakres: (1,0 – 500) mg/l Metoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":27,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Kjeldahl nitrogen concentration Range: (1,0 – 500) mg/l Titrimetric method PN-EN 25663:2001","search_zh":"污水 凯氏氮浓度 范围：(1,0 – 500) mg/l 滴定法 PN-EN 25663:2001","test_object_zh":"污水","methodology_zh":"凯氏氮浓度 范围：(1,0 – 500) mg/l 滴定法"},{"_id":"6a5a55f49af9f73f382518f7","lab_id":"69ad52a3de79e566650fb656","country":"PL","accr_number":"AB 1231","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu amonowego Zakres: (0,50 – 200) mg/l Metoda miareczkowa","methodology_en":"Ammonium nitrogen concentration Range: (0,50 – 200) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego Zakres: (0,50 – 200) mg/l Metoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu amonowego Zakres: (0,50 – 200) mg/l Metoda miareczkowa PN-ISO 5664:2002 Scieki Stezenie azotu amonowego Zakres: (0,50 – 200) mg/l Metoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":28,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Ammonium nitrogen concentration Range: (0,50 – 200) mg/l Titrimetric method PN-ISO 5664:2002","search_zh":"污水 PN-ISO 5664:2002","test_object_zh":"污水"},{"_id":"6a5a55f49af9f73f382518f8","lab_id":"69ad52a3de79e566650fb656","country":"PL","accr_number":"AB 1231","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu azotanowego Zakres: (0,10 – 60) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrate nitrogen concentration Range: (0,10 – 60) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu azotanowego Zakres: (0,10 – 60) mg/l Metoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu azotanowego Zakres: (0,10 – 60) mg/l Metoda spektrofotometryczna PN-82/C-04576/08 Scieki Stezenie azotu azotanowego Zakres: (0,10 – 60) mg/l Metoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":29,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Nitrate nitrogen concentration Range: (0,10 – 60) mg/l Spectrophotometric method PN-82/C-04576/08","search_zh":"污水 PN-82/C-04576/08","test_object_zh":"污水"},{"_id":"6a5a55f49af9f73f382518f9","lab_id":"69ad52a3de79e566650fb656","country":"PL","accr_number":"AB 1231","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu azotynowego Zakres: (0,050 – 6,0) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrite nitrogen concentration Range: (0,050 – 6,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego Zakres: (0,050 – 6,0) mg/l Metoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu azotynowego Zakres: (0,050 – 6,0) mg/l Metoda spektrofotometryczna PN-EN 26777:1999 Scieki Stezenie azotu azotynowego Zakres: (0,050 – 6,0) mg/l Metoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":30,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Nitrite nitrogen concentration Range: (0,050 – 6,0) mg/l Spectrophotometric method PN-EN 26777:1999","search_zh":"污水 PN-EN 26777:1999","test_object_zh":"污水"},{"_id":"6a5a55f49af9f73f382518fa","lab_id":"69ad52a3de79e566650fb656","country":"PL","accr_number":"AB 1231","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu ogólnego (z obliczeń)","methodology_en":"Total nitrogen concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PN-73/C-04576/14","norm_bases":["PN-73/C-04576/14"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu ogólnego (z obliczeń) PN-73/C-04576/14 Scieki Stezenie azotu ogolnego (z obliczen) PN-73/C-04576/14","categories":["water"],"row_index":31,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Total nitrogen concentration (calculated) PN-73/C-04576/14","methodology_zh":"总氮浓度（计算值）","search_zh":"污水 总氮浓度（计算值） PN-73/C-04576/14","test_object_zh":"污水"},{"_id":"6a5a55f49af9f73f382518fb","lab_id":"69ad52a3de79e566650fb656","country":"PL","accr_number":"AB 1231","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie fosforu ogólnego Zakres: (0,040 – 50,0) mg/l Metoda spektrofotometryczna","methodology_en":"Total phosphorus concentration Range: (0,040 – 50,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego Zakres: (0,040 – 50,0) mg/l Metoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie fosforu ogólnego Zakres: (0,040 – 50,0) mg/l Metoda spektrofotometryczna PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010 Scieki Stezenie fosforu ogolnego Zakres: (0,040 – 50,0) mg/l Metoda spektrofotometryczna PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":32,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Total phosphorus concentration Range: (0,040 – 50,0) mg/l Spectrophotometric method PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010","search_zh":"污水 PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010","test_object_zh":"污水"},{"_id":"6a5a55f49af9f73f382518fc","lab_id":"69ad52a3de79e566650fb656","country":"PL","accr_number":"AB 1231","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Substancje ekstrahujące się eterem naftowym Zakres: (5,0 – 1000) mg/l Metoda wagowa","methodology_en":"Substances extractable with petroleum ether Range: (5,0 – 1000) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Substancje ekstrahujące się eterem naftowym Zakres: (5,0 – 1000) mg/l Metoda wagowa","reference":"PB-04 wyd.4 z dnia 24.03.2025 r.","norm_bases":["PB-04 wyd.4 z dnia 24.03.2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Substancje ekstrahujące się eterem naftowym Zakres: (5,0 – 1000) mg/l Metoda wagowa PB-04 wyd.4 z dnia 24.03.2025 r. Scieki Substancje ekstrahujace sie eterem naftowym Zakres: (5,0 – 1000) mg/l Metoda wagowa PB-04 wyd.4 z dnia 24.03.2025 r.","categories":["water"],"row_index":33,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Substances extractable with petroleum ether Range: (5,0 – 1000) mg/l Gravimetric method PB-04 wyd.4 z dnia 24.03.2025 r.","search_zh":"污水 石油醚可萃取物质 范围：(5,0 – 1000) mg/l 重量法 PB-04 wyd.4 z dnia 24.03.2025 r.","test_object_zh":"污水","methodology_zh":"石油醚可萃取物质 范围：(5,0 – 1000) mg/l 重量法"},{"_id":"6a5a55f49af9f73f382518fd","lab_id":"69ad52a3de79e566650fb656","country":"PL","accr_number":"AB 1231","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie kationów Zakres: potas (1,0 − 50) mg/l sód (1,0 − 200) mg/l jon amonowy (0,050 – 2,0) mg/l wapń (1,0 − 100) mg/l magnez (1,0 − 150) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","methodology_en":"Cation concentration Range: potassium (1,0 − 50) mg/l sodium (1,0 − 200) mg/l ammonium ion (0,050 – 2,0) mg/l calcium (1,0 − 100) mg/l magnesium (1,0 − 150) mg/l Ion chromatography with conductometric detection (IC-CD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie kationów Zakres: potas (1,0 − 50) mg/l sód (1,0 − 200) mg/l jon amonowy (0,050 – 2,0) mg/l wapń (1,0 − 100) mg/l magnez (1,0 − 150) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 14911:2002","norm_bases":["PN-EN ISO 14911:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie kationów Zakres: potas (1,0 − 50) mg/l sód (1,0 − 200) mg/l jon amonowy (0,050 – 2,0) mg/l wapń (1,0 − 100) mg/l magnez (1,0 − 150) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 14911:2002 Woda, woda do spozycia przez ludzi Stezenie kationow Zakres: potas (1,0 − 50) mg/l sod (1,0 − 200) mg/l jon amonowy (0,050 – 2,0) mg/l wapn (1,0 − 100) mg/l magnez (1,0 − 150) mg/l Metoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 14911:2002","categories":["water"],"row_index":34,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Cation concentration Range: potassium (1,0 − 50) mg/l sodium (1,0 − 200) mg/l ammonium ion (0,050 – 2,0) mg/l calcium (1,0 − 100) mg/l magnesium (1,0 − 150) mg/l Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 14911:2002","search_zh":"水、生活饮用水 PN-EN ISO 14911:2002","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55f49af9f73f382518fe","lab_id":"69ad52a3de79e566650fb656","country":"PL","accr_number":"AB 1231","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Stężenie anionów Zakres: fluorki (0,10 − 2,00) mg/l chlorki (5,0 − 1000) mg/l fosforany (0,10 – 10,0) mg/l siarczany (5,0 − 1000) mg/l azotyny (0,050 – 5,0) mg/l azotany (0,50 – 100) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Stężenie azotu azotynowego (z obliczeń) Stężenie azotu azotanowego (z obliczeń)","methodology_en":"Anion concentrations Range: fluorides (0,10 − 2,00) mg/l chlorides (5,0 − 1000) mg/l phosphates (0,10 – 10,0) mg/l sulfates (5,0 − 1000) mg/l nitrites (0,050 – 5,0) mg/l nitrates (0,50 – 100) mg/l Ion chromatography with conductometric detection (IC-CD) Nitrite nitrogen concentration (calculated) Nitrate nitrogen concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie anionów Zakres: fluorki (0,10 − 2,00) mg/l chlorki (5,0 − 1000) mg/l fosforany (0,10 – 10,0) mg/l siarczany (5,0 − 1000) mg/l azotyny (0,050 – 5,0) mg/l azotany (0,50 – 100) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Stężenie azotu azotynowego (z obliczeń) Stężenie azotu azotanowego (z obliczeń)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie anionów Zakres: fluorki (0,10 − 2,00) mg/l chlorki (5,0 − 1000) mg/l fosforany (0,10 – 10,0) mg/l siarczany (5,0 − 1000) mg/l azotyny (0,050 – 5,0) mg/l azotany (0,50 – 100) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) Stężenie azotu azotynowego (z obliczeń) Stężenie azotu azotanowego (z obliczeń) PN-EN ISO 10304-1:2009+AC:2012 Woda, woda do spozycia przez ludzi, scieki Stezenie anionow Zakres: fluorki (0,10 − 2,00) mg/l chlorki (5,0 − 1000) mg/l fosforany (0,10 – 10,0) mg/l siarczany (5,0 − 1000) mg/l azotyny (0,050 – 5,0) mg/l azotany (0,50 – 100) mg/l Metoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) Stezenie azotu azotynowego (z obliczen) Stezenie azotu azotanowego (z obliczen) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":35,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption, wastewater Anion concentrations Range: fluorides (0,10 − 2,00) mg/l chlorides (5,0 − 1000) mg/l phosphates (0,10 – 10,0) mg/l sulfates (5,0 − 1000) mg/l nitrites (0,050 – 5,0) mg/l nitrates (0,50 – 100) mg/l Ion chromatography with conductometric detection (IC-CD) Nitrite nitrogen concentration (calculated) Nitrate nitrogen concentration (calculated) PN-EN ISO 10304-1:2009+AC:2012","search_zh":"水、生活饮用水、污水 PN-EN ISO 10304-1:2009+AC:2012","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5a55f49af9f73f382518ff","lab_id":"69ad52a3de79e566650fb656","country":"PL","accr_number":"AB 1231","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, woda na pływalniach","test_object_en":"Water, water intended for human consumption, swimming pool water","methodology":"Pobieranie próbek do badań mikrobiologicznych","methodology_en":"Sampling for microbiological testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.4","norm_bases":["PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, woda na pływalniach Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.4 Woda, woda do spozycia przez ludzi, woda na plywalniach Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007 z wylaczeniem pkt. 4.4.4","categories":["water","microbiology"],"row_index":36,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption, swimming pool water Sampling for microbiological testing PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.4","methodology_zh":"微生物检测用样品采集","search_zh":"水、生活饮用水、游泳池水 微生物检测用样品采集 PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.4","test_object_zh":"水、生活饮用水、游泳池水"},{"_id":"6a5a55f49af9f73f38251900","lab_id":"69ad52a3de79e566650fb656","country":"PL","accr_number":"AB 1231","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Liczba bakterii grupy coli Metoda filtracji membranowej","methodology_en":"Coliform bacteria count Membrane filtration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba bakterii grupy coli Metoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Liczba bakterii grupy coli Metoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda, woda do spozycia przez ludzi Liczba bakterii grupy coli Metoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":37,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","methodology_zh":"大肠菌群计数 膜过滤法","search_zh":"水、生活饮用水 大肠菌群计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55f49af9f73f38251901","lab_id":"69ad52a3de79e566650fb656","country":"PL","accr_number":"AB 1231","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Liczba bakterii Escherichia coli Metoda filtracji membranowej","methodology_en":"Escherichia coli bacteria count Membrane filtration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba bakterii Escherichia coli Metoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Liczba bakterii Escherichia coli Metoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda, woda do spozycia przez ludzi Liczba bakterii Escherichia coli Metoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["microbiology","water"],"row_index":38,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Escherichia coli bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","search_zh":"水、生活饮用水 大肠埃希氏菌数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","test_object_zh":"水、生活饮用水","methodology_zh":"大肠埃希氏菌数 膜过滤法"},{"_id":"6a5a55f49af9f73f38251902","lab_id":"69ad52a3de79e566650fb656","country":"PL","accr_number":"AB 1231","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Ogólna liczba mikroorganizmów w temp. 36ºC Metoda płytkowa (posiew wgłębny)","methodology_en":"Total count of microorganisms at 36ºC Plate method (pour plate)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w temp. 36ºC Metoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temp. 36ºC Metoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda, woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temp. 36ºC Metoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":39,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Total count of microorganisms at 36ºC Plate method (pour plate) PN-EN ISO 6222:2004","search_zh":"水、生活饮用水 PN-EN ISO 6222:2004","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55f49af9f73f38251903","lab_id":"69ad52a3de79e566650fb656","country":"PL","accr_number":"AB 1231","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Ogólna liczba mikroorganizmów w temp. 22ºC Metoda płytkowa (posiew wgłębny)","methodology_en":"Total count of microorganisms at 22ºC Plate method (pour plate)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w temp. 22ºC Metoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temp. 22ºC Metoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda, woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temp. 22ºC Metoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":40,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Total count of microorganisms at 22ºC Plate method (pour plate) PN-EN ISO 6222:2004","search_zh":"水、生活饮用水 PN-EN ISO 6222:2004","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55f49af9f73f38251904","lab_id":"69ad52a3de79e566650fb656","country":"PL","accr_number":"AB 1231","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Liczba enterokoków kałowych Metoda filtracji membranowej","methodology_en":"Intestinal enterococci count Membrane filtration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba enterokoków kałowych Metoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Liczba enterokoków kałowych Metoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda, woda do spozycia przez ludzi Liczba enterokokow kalowych Metoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":41,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004","search_zh":"水、生活饮用水 肠球菌计数 膜过滤法 PN-EN ISO 7899-2:2004","test_object_zh":"水、生活饮用水","methodology_zh":"肠球菌计数 膜过滤法"},{"_id":"6a5a55f49af9f73f38251905","lab_id":"69ad52a3de79e566650fb656","country":"PL","accr_number":"AB 1231","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Liczba Pseudomonas aeruginosa Metoda filtracji membranowej","methodology_en":"Pseudomonas aeruginosa count Membrane filtration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba Pseudomonas aeruginosa Metoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Liczba Pseudomonas aeruginosa Metoda filtracji membranowej PN-EN ISO 16266:2009 Woda, woda do spozycia przez ludzi Liczba Pseudomonas aeruginosa Metoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":42,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009","search_zh":"水、生活饮用水 铜绿假单胞菌计数 膜过滤法 PN-EN ISO 16266:2009","test_object_zh":"水、生活饮用水","methodology_zh":"铜绿假单胞菌计数 膜过滤法"},{"_id":"6a5a55f49af9f73f38251906","lab_id":"69ad52a3de79e566650fb656","country":"PL","accr_number":"AB 1231","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Liczba bakterii z rodzaju Legionella Metoda filtracji membranowej Matryca A Procedura 5 (pożywka A), 7 (pożywka C-GVPC)","methodology_en":"Count of bacteria of the genus Legionella Membrane filtration method Matrix A Procedure 5 (medium A), 7 (medium C-GVPC)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba bakterii z rodzaju Legionella Metoda filtracji membranowej Matryca A Procedura 5 (pożywka A), 7 (pożywka C-GVPC)","reference":"PN-EN ISO 11731:2017-08 +Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08 +Ap1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Liczba bakterii z rodzaju Legionella Metoda filtracji membranowej Matryca A Procedura 5 (pożywka A), 7 (pożywka C-GVPC) PN-EN ISO 11731:2017-08 +Ap1:2019-12 Woda, woda do spozycia przez ludzi Liczba bakterii z rodzaju Legionella Metoda filtracji membranowej Matryca A Procedura 5 (pozywka A), 7 (pozywka C-GVPC) PN-EN ISO 11731:2017-08 +Ap1:2019-12","categories":["microbiology","water"],"row_index":43,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Count of bacteria of the genus Legionella Membrane filtration method Matrix A Procedure 5 (medium A), 7 (medium C-GVPC) PN-EN ISO 11731:2017-08 +Ap1:2019-12","search_zh":"水、生活饮用水 PN-EN ISO 11731:2017-08 +Ap1:2019-12","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55f49af9f73f38251907","lab_id":"69ad52a3de79e566650fb656","country":"PL","accr_number":"AB 1231","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Liczba bakterii Escherichia coli Metoda filtracji membranowej","methodology_en":"Escherichia coli bacteria count Membrane filtration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba bakterii Escherichia coli Metoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Liczba bakterii Escherichia coli Metoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda na plywalniach Liczba bakterii Escherichia coli Metoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["microbiology","water"],"row_index":44,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Swimming pool water Escherichia coli bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","search_zh":"游泳池水 大肠埃希氏菌数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","test_object_zh":"游泳池水","methodology_zh":"大肠埃希氏菌数 膜过滤法"},{"_id":"6a5a55f49af9f73f38251908","lab_id":"69ad52a3de79e566650fb656","country":"PL","accr_number":"AB 1231","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Ogólna liczba mikroorganizmów w temp. 36ºC Metoda płytkowa (posiew wgłębny)","methodology_en":"Total count of microorganisms at 36ºC Plate method (pour plate)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w temp. 36ºC Metoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Ogólna liczba mikroorganizmów w temp. 36ºC Metoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda na plywalniach Ogolna liczba mikroorganizmow w temp. 36ºC Metoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":45,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Swimming pool water Total count of microorganisms at 36ºC Plate method (pour plate) PN-EN ISO 6222:2004","search_zh":"游泳池水 PN-EN ISO 6222:2004","test_object_zh":"游泳池水"},{"_id":"6a5a55f49af9f73f38251909","lab_id":"69ad52a3de79e566650fb656","country":"PL","accr_number":"AB 1231","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Liczba Pseudomonas aeruginosa Metoda filtracji membranowej","methodology_en":"Pseudomonas aeruginosa count Membrane filtration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba Pseudomonas aeruginosa Metoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Liczba Pseudomonas aeruginosa Metoda filtracji membranowej PN-EN ISO 16266:2009 Woda na plywalniach Liczba Pseudomonas aeruginosa Metoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":46,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Swimming pool water Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009","search_zh":"游泳池水 铜绿假单胞菌计数 膜过滤法 PN-EN ISO 16266:2009","test_object_zh":"游泳池水","methodology_zh":"铜绿假单胞菌计数 膜过滤法"},{"_id":"6a5a55f49af9f73f3825190a","lab_id":"69ad52a3de79e566650fb656","country":"PL","accr_number":"AB 1231","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Liczba bakterii z rodzaju Legionella Metoda filtracji membranowej Matryca A Procedura 5 (pożywka A), 7 (pożywka C-GVPC)","methodology_en":"Count of bacteria of the genus Legionella Membrane filtration method Matrix A Procedure 5 (medium A), 7 (medium C-GVPC)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba bakterii z rodzaju Legionella Metoda filtracji membranowej Matryca A Procedura 5 (pożywka A), 7 (pożywka C-GVPC)","reference":"PN-EN ISO 11731:2017-08 +Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08 +Ap1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Liczba bakterii z rodzaju Legionella Metoda filtracji membranowej Matryca A Procedura 5 (pożywka A), 7 (pożywka C-GVPC) PN-EN ISO 11731:2017-08 +Ap1:2019-12 Woda na plywalniach Liczba bakterii z rodzaju Legionella Metoda filtracji membranowej Matryca A Procedura 5 (pozywka A), 7 (pozywka C-GVPC) PN-EN ISO 11731:2017-08 +Ap1:2019-12","categories":["microbiology","water"],"row_index":47,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Swimming pool water Count of bacteria of the genus Legionella Membrane filtration method Matrix A Procedure 5 (medium A), 7 (medium C-GVPC) PN-EN ISO 11731:2017-08 +Ap1:2019-12","search_zh":"游泳池水 PN-EN ISO 11731:2017-08 +Ap1:2019-12","test_object_zh":"游泳池水"}],"has_pdf":true}