🇵🇱 Laboratorium Badawcze EHS-LAB Sp. z o.o. PL
EnvironmentWater & wastewater
Laboratorium Badawcze EHS-LAB Sp. z o.o. is a laboratory accredited by PCA under number AB 1226 (Kraków, Poland). Its accreditation scope covers 101 test methods in the following areas: Environment, Water & wastewater. Test objects include: Workplace environment - air *, Water and wastewater, Water, Wastewater. Most frequently used techniques: Gas chromatography with flame ionization detection (GC – FID), Direct measurement method, Spectrophotometric method.
At a glance
- Accreditation number: PCA AB 1226
- Methods in scope: 101
- Types of test objects: 14
- Techniques used: 21
- City: Kraków, Poland
- Accreditation number
- AB 1226
- Accreditation body
- PCA
- Address
- ul. Okólna 11/69, 30-669 Kraków
- City
- Kraków, Poland
What this laboratory tests (14)
- Workplace environment - air * — 52 methods
- Water and wastewater — 15 methods
- Water — 7 methods
- Wastewater — 5 methods
- Środowisko pracy - hałas * — 4 methods
- General environment - noise from installations, equipment and industrial plants — 2 methods
- Środowisko pracy - drgania o działaniu ogólnym na organizm człowieka * — 2 methods
- Środowisko pracy - drgania przenoszone przez kończyny górne * — 2 methods
- Środowisko pracy - mikroklimat gorący * — 2 methods
- Środowisko pracy - mikroklimat zimny * — 2 methods
- Środowisko pracy - oświetlenie miejsce pracy światłem elektrycznym * — 2 methods
- Środowisko pracy – hałas ultradźwiękowy * — 2 methods
- Workplace environment - indoor electric lighting * — 2 methods
- Workplace environment - moderate microclimate * — 2 methods
Analytical techniques used (21)
- Gas chromatography with flame ionization detection (GC – FID) — 22 methods
- Direct measurement method — 10 methods
- Spectrophotometric method — 10 methods
- Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC –FID) — 5 methods
- Titrimetric method — 5 methods
- Gravimetric method — 4 methods
- Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC UV) — 4 methods
- Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC UV/DAD) — 3 methods
- Conductometric method — 2 methods
- Electrochemical method — 2 methods
- Gas chromatography with flame ionization detection (GC-FID) — 2 methods
- Manual method — 2 methods
- Metoda wysokosprawnej chromatografii cieczowej (HPLC - UV) — 2 methods
- Personal dosimetry method — 2 methods
- Potentiometric method — 2 methods
- and 6 more
Laboratory locations
- Laboratorium Badawcze EHS-LAB Sp. z o.o. — ul. Okólna 11/69
- Laboratorium Badawcze EHS-LAB — ul. Mogilska 80, 31-546 Kraków (działalność techniczna)
Accreditation scope — test methods (101)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Laboratorium Badawcze EHS-LAB | |||||
| 1 | Środowisko pracy - hałas * | A-weighted equivalent sound level Maximum A-weighted sound level Range (25 - 135) dB C-weighted peak sound pressure level Range (40 - 138) dB |
Direct measurement method | PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących strategię 2 i 3 – punkt 10 i 11 | PN-N-01307:1994 | |
| 2 | Środowisko pracy - hałas * | Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated) |
PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących strategię 2 i 3 – punkt 10 i 11 | PN-N-01307:1994 | ||
| 3 | Środowisko pracy – hałas ultradźwiękowy * | Równoważne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz Maksymalne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz Range (59 – 160) dB |
Direct measurement method | PN-Z-01339:2020-12 | |
| 4 | Środowisko pracy – hałas ultradźwiękowy * | Equivalent sound pressure levels in third-octave bands with centre frequencies from 10 kHz to 40 kHz referred to: an 8-hour daily working time the average weekly working time (calculated) |
PN-Z-01339:2020-12 | ||
| 5 | General environment - noise from installations, equipment and industrial plants | A-weighted equivalent sound pressure level Range (25 – 135) dB |
Direct measurement method | Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023, poz. 1706) z wyłączeniem punktu F | |
| 6 | General environment - noise from installations, equipment and industrial plants | A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) | Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023, poz. 1706) z wyłączeniem punktu F | ||
| 7 | Środowisko pracy - drgania o działaniu ogólnym na organizm człowieka * | Frequency-weighted r.m.s. vibration acceleration Range (0,01 – 40) m/s2 |
Direct measurement method; Sampling method | PN-EN 14253+A1:2011 | |
| 8 | Środowisko pracy - drgania o działaniu ogólnym na organizm człowieka * | Daily exposure, expressed as the 8-hour energy-equivalent frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1.4awx, 1.4awy, awz)., Exposure lasting 30 minutes and less, expressed as the frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1.4awx, 1.4awy, awz) (calculated) | PN-EN 14253+A1:2011 | ||
| 9 | Środowisko pracy - drgania przenoszone przez kończyny górne * | Frequency-weighted r.m.s. vibration acceleration Range (0,06 – 60) m/s2 |
Direct measurement method | PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 | |
| 10 | Środowisko pracy - drgania przenoszone przez kończyny górne * | Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz)., Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych. (ahwx, ahwy, ahwz). (z obliczeń) | PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 | ||
| 11 | Środowisko pracy - mikroklimat zimny * | Air temperature Range (-10 – 10) °C Black globe temperature Range (-10 – 10) °C Air humidity Range (25 – 75) % Air velocity Range (0,15 – 5) m/s |
Direct measurement method | PN-EN ISO 11079:2008 | |
| 12 | Środowisko pracy - mikroklimat zimny * | IREQmin index, IREQneutral index, twc index (calculated) | PN-EN ISO 11079:2008 | ||
| 13 | Workplace environment - moderate microclimate * | Air temperature Range (10 – 40) °C Black globe temperature Range (10 – 40) °C Air humidity Range (25 – 75) % Air velocity Range (0,15 – 5) m/s |
Direct measurement method | PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006+Ap2:2016-04 | |
| 14 | Workplace environment - moderate microclimate * | PMV index, PPD index (calculated) | PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006+Ap2:2016-04 | ||
| 15 | Środowisko pracy - mikroklimat gorący * | Air temperature Range (15 – 40) °C Natural wet bulb temperature Range (15 – 40) °C Black globe temperature Range (15 – 50) °C |
Direct measurement method | PN-EN ISO 7243:2018-01 | |
| 16 | Środowisko pracy - mikroklimat gorący * | WBGT index, WBGTeff index (calculated) | PN-EN ISO 7243:2018-01 | ||
| 17 | Workplace environment - indoor electric lighting * | Illuminance Range (5 – 5000) lx |
Direct measurement method | PN-83/E-04040.03 | |
| 18 | Workplace environment - indoor electric lighting * | Illuminance uniformity (calculated) | PN-83/E-04040.03 | ||
| 19 | Workplace environment - air * | Gas concentrations: CO (2,3 – 200) mg/m3 |
Electrochemical method | EHS-PB-43 wyd. 3 z 01.06.2022 | |
| 20 | Workplace environment - air * | Exposure index (calculated) | EHS-PB-43 wyd. 3 z 01.06.2022 | ||
| 21 | Workplace environment - air * | Sampling for the assessment of occupational exposure to: dust agents inhalable fraction respirable fraction |
Personal dosimetry method | PN-Z-04008-7:2002+Az1:2004 | |
| 22 | Workplace environment - air * | Sampling for the assessment of occupational exposure to: organic substances, including inhalable fraction inorganic substances, including inhalable fraction respirable fraction thoracic fraction metals and their compounds, including inhalable fraction respirable fraction |
Personal dosimetry method; Stationary method | PN-Z-04008-7:2002+Az1:2004 | |
| 23 | Workplace environment - air * | Exposure index (calculated) | PN-Z-04008-7:2002+Az1:2004 | ||
| 24 | Workplace environment - air * | Concentration of harmful dust agents – inhalable fraction apatites and phosphorites portland cement titanium dioxide natural graphite synthetic graphite kaolin amorphous and synthetic silica wood dusts flour dusts dusts not classified according to toxicity organic dusts of animal and plant origin, excluding wood and flour dusts carbon black calcium sulfate (VI) (gypsum) talc coal (hard, brown) calcium magnesium carbonate (dolomite) silicon carbide, non-fibrous Range (0,5 – 68,0) mg/m3 |
Gravimetric method | PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 | |
| 25 | Workplace environment - air * | Concentration of harmful dust agents – respirable fraction apatites and phosphorites portland cement natural graphite amorphous and synthetic silica organic dusts of animal and plant origin, excluding wood and flour dusts talc coal (hard, brown) Range (0,3 – 14,6) mg/m3 |
Gravimetric method | PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 | |
| 26 | Workplace environment - air * | Stężenie/zawartość acetonitrylu, N,N-dimetyloformamidu acetonitryl: (2,2 – 250) mg/m3 Range (0,04 – 0,88) mg w próbce N,N-dimetyloformamid: (0,5 – 60) mg/m3 (0,09 – 1,8) mg w próbce |
Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC –FID) | EHS-PB-1 wyd. 5 z 17.04.2019 | |
| 27 | Workplace environment - air * | Stężenie/zawartość n-heksanu, n-heptanu n-hexane (5,0 – 200) mg/m3 Range (0,03 – 1,2) mg w próbce n-heptane (66,7 – 2667) mg/m3 (0,40 – 16,0) mg w próbce |
Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC –FID) | NIOSH Method 1500 Issue 3 (2003) | |
| 28 | Workplace environment - air * | Stężenie/zawartość etanolu, propan-2-olu ethanol (180 – 4050) mg/m3 Range (0,18 – 4,05) mg w próbce propan-2-ol (80 – 1800) mg/m3 (0,24 – 5,40) mg w próbce |
Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC –FID) | NIOSH Method 1400 Issue 2 (1994) | |
| 29 | Workplace environment - air * | Concentration/content of tetrahydrofuran Range (15 – 300) mg/m3 Range (0,075 – 1,5) mg w próbce |
Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC –FID) | PN-Z-04481:2017-10 | |
| 30 | Workplace environment - air * | Methanol concentration/content Range (10 – 200) mg/m3 Range (0,05 – 1,00) mg w próbce |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04476:2016-10 | |
| 31 | Workplace environment - air * | Acetic acid concentration/content Range (1,0 – 50) mg/m3 Range (0,025 – 1,25) mg w próbce |
Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC –FID) | PN-Z-04323:2004 | |
| 32 | Workplace environment - air * | Methyl acetate concentration/content methyl acetate (20 – 500) mg/m3 Range (0,20 – 5,0) mg w próbce |
Gas chromatography with flame ionization detection (GC – FID) | NIOSH Method 1458 Issue 2 (1994) EHS-PB-10 wyd. 5 z 29.05.2019 | |
| 33 | Workplace environment - air * | Ethyl acetate concentration/content Range (60 – 1500) mg/m3 Range (0,60 – 15) mg w próbce |
Gas chromatography with flame ionization detection (GC-FID) | NIOSH Method 1457 Issue 1 (1994) EHS-PB-10 wyd. 5 z 29.05.2019 | |
| 34 | Workplace environment - air * | Stężenie/zawartość octanu n-propylu, octanu n-butylu, octanu n-amylu octan n-propylu (20 - 500) mg/m3 Range (0,20 – 5,0) mg w próbce n-butyl acetate (20 - 500) mg/m3 (0,20 – 5,0) mg w próbce pentyl acetate (20 – 500) mg/m3 (0,20 – 5,0) mg w próbce |
Gas chromatography with flame ionization detection (GC – FID) | NIOSH Method 1450 Issue 3 (2003) EHS-PB-10 wyd. 5 z 29.05.2019 | |
| 35 | Workplace environment - air * | Extraction naphtha concentration/content Range (12,5 – 1500) mg/m3 Range (0,125 – 6,0) mg w próbce |
Gas chromatography with flame ionization detection (GC – FID) | PN-Z-04134-02:1981 | |
| 36 | Workplace environment - air * | Stężenie/zawartość benzenu, toluenu, etylobenzenu, o-ksylenu, m-ksylenu, p-ksylenu benzene (0,10 – 4,0) mg/m3 Range (0,003 – 0,12) mg w próbce toluene (5,0 – 200) mg/m3 (0,04 – 1,6) mg w próbce ethylbenzene (10 – 400) mg/m3 (0,24 – 9,6) mg w próbce o-xylene (7,5 – 300) mg/m3 (0,18 – 7,2) mg w próbce m-xylene (7,5 – 300) mg/m3 (0,18 – 7,2) mg w próbce p-xylene (7,5 – 300) mg/m3 (0,18 – 7,2) mg w próbce |
Gas chromatography with flame ionization detection (GC – FID) | NIOSH Method 1501 Issue 3 (2003) | |
| 37 | Workplace environment - air * | Stężenie/zawartość acetonu, 4-metylopentan-2-onu acetone (60 – 2400) mg/m3 Range (0,18 – 7,2) mg w próbce 4-methylpentan-2-one (6,0 – 240) mg/m3 (0,06 – 2,4) mg w próbce |
Gas chromatography with flame ionization detection (GC – FID) | NIOSH Method 1300 Issue 2 (1994) | |
| 38 | Workplace environment - air * | Dichloromethane concentration/content dichloromethane (8,8 – 176) mg/m3 Range (0,0528 – 1,056) mg w próbce |
Gas chromatography with flame ionization detection (GC – FID) | PN-Z-04437:2011 | |
| 39 | Workplace environment - air * | Concentration/content of chloroform Range (0,40 – 16) mg/m3 Range (0,02 – 0,80) mg w próbce |
Gas chromatography with flame ionization detection (GC – FID) | NIOSH Method 1003 Issue 3 (2003) | |
| 40 | Workplace environment - air * | Stężenie/zawartość 1-butanolu Range (5,0 – 300) mg/m3 Range (0,05 – 3,0) mg w próbce |
Gas chromatography with flame ionization detection (GC – FID) | NIOSH Method 1405 Issue 1 (2003) | |
| 41 | Workplace environment - air * | White spirit concentration/content Range (2,78 – 614,7) mg/m3 Range (0,10 – 22,13) mg w próbce |
Gas chromatography with flame ionization detection (GC – FID) | PN-81/Z-04134.03 | |
| 42 | Workplace environment - air * | Turpentine concentration/content Range (10 – 300) mg/m3 Range (0,10 – 3,0) mg w próbce |
Gas chromatography with flame ionization detection (GC – FID) | NIOSH Method 1551 Issue 2 (1994) | |
| 43 | Workplace environment - air * | Concentration/content of 1,4-dioxane Range (1,4 – 115) mg/m3 Range (0,05 – 4,13) mg w próbce |
Gas chromatography with flame ionization detection (GC – FID) | Podstawy i Metody Oceny Środowiska Pracy 2009, nr 1(59), s. 141–146 | |
| 44 | Workplace environment - air * | Kerosene concentration/content Range (10,00 – 4800) mg/m3 Range (0,36 – 7,2) mg w próbce |
Gas chromatography with flame ionization detection (GC – FID) | PN-Z-04227-02:1992 | |
| 45 | Workplace environment - air * | Stężenie/zawartość trimetylobenzenów, styrenu, cykloheksanu, cykloheksanonu, butan-2-onu 1,2,3-trimethylbenzene Range (9 – 4330) mg/m3 Range (0,32 – 6,5) mg w próbce 1,2,4-trimethylbenzene (10 – 4767) mg/m3 (0,36 – 7,2) mg w próbce 1,3,5-trimethylbenzene (10 – 4767) mg/m3 (0,36 – 7,2) mg w próbce Suma trimetylobenzenów (z obliczeń) styrene (5,3 – 2480) mg/m3 (0,19 – 3,7) mg w próbce cyclohexane (30 – 14400) mg/m3 (1,1 – 21,6) mg w próbce cyclohexanone (3,9 – 1920) mg/m3 (0,14 – 2,88) mg w próbce butan-2-one (45 – 22000) mg/m3 (1,6 – 32,5) mg w próbce |
Gas chromatography with flame ionization detection (GC – FID) | Podstawy i Metody Oceny Środowiska Pracy 2007, nr 1 (51), s. 141 - 147 | |
| 46 | Workplace environment - air * | Stężenie/zawartość adypinianu bis(2-etyloheksylu) Range (40 – 800) mg/m3 Range (6 – 120) mg w próbce |
Gas chromatography with flame ionization detection (GC – FID) | PN-Z-04461:2015-10 | |
| 47 | Workplace environment - air * | Stężenie/zawartość N,N-dimetyloacetamidu Range (2,0 – 160) mg/m3 Range (0,020 – 1,6) mg w próbce |
Gas chromatography with flame ionization detection (GC – FID) | PN-Z-04491:2017-10 | |
| 48 | Workplace environment - air * | Ethylene glycol concentration/content Range (1,50 – 100) mg/m3 Range (0,030 – 2,0) mg w próbce |
Gas chromatography with flame ionization detection (GC – FID) | Podstawy i Metody Oceny Środowiska Pracy 1997, nr 17, s. 55-59 | |
| 49 | Workplace environment - air * | 2-methoxy-1-methylethyl acetate concentration/content Range (26 – 1200) mg/m3 Range (0,26 – 12) mg w próbce |
Gas chromatography with flame ionization detection (GC – FID) | PN-Z-04119-10:2008 | |
| 50 | Workplace environment - air * | Stężenie/zawartość octanu 2-metoksypropylu Range (10 – 400) mg/m3 Range (0,050 – 2,0) mg w próbce |
Gas chromatography with flame ionization detection (GC – FID) | PN-Z-04305:2003 | |
| 51 | Workplace environment - air * | Stężenie/zawartość glicerolu – frakcja wdychalna Range (1,01 – 20,20) mg/m3 Range (0,20 – 4,00) mg w próbce |
Gas chromatography with flame ionization detection (GC – FID) | PN-Z-04374:2009 | |
| 52 | Workplace environment - air * | Phenol concentration/content Range (0,71 – 30,30) mg/m3 Range (0,014 – 0,600) mg w próbce |
Gas chromatography with flame ionization detection (GC – FID) | NIOSH Method 2546 Issue 1:1994 | |
| 53 | Workplace environment - air * | Concentration/content of 1,2-dichloroethane Range (0,82 – 16,40) mg/m3 Range (0,010 – 0,197) mg w próbce |
Gas chromatography with flame ionization detection (GC – FID) | PN-Z-04501:2019-10 | |
| 54 | Workplace environment - air * | Stężenie/zawartość 1,2-dichloroetenu – izomerów: cis -, trans - cis 1,2-dichloroethene Range (70,70 – 1414,14) mg/m3 Range (0,70 – 14,00) mg w próbce trans 1,2-dichloroethene (70,70 – 1414,14) mg/m3 (0,70 – 14,00) mg w próbce |
Gas chromatography with flame ionization detection (GC – FID) | PN-Z-04270:2000 | |
| 55 | Workplace environment - air * | Acrylic acid concentration/content Range (1,0 – 40) mg/m3 Range (0,02 – 0,8) mg w próbce |
Metoda wysokosprawnej chromatografii cieczowej (HPLC - UV) | PN-Z-04460:2014-09 | |
| 56 | Workplace environment - air * | Concentration/content of hydroquinone Range (0,1 – 2) mg/m3 Range (0,0018 – 0,036) mg w próbce |
Metoda wysokosprawnej chromatografii cieczowej (HPLC - UV) | PN-Z-04479:2016 | |
| 57 | Workplace environment - air * | Stężenie/zawartość nadtlenku dibenzoilowego Range (0,505 – 20,0) mg/m3 Range (0,050 – 2,0) mg w próbce |
Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC UV/DAD) | Podstawy i Metody Oceny Środowiska Pracy 2016, nr 17, s. 97-100 | |
| 58 | Workplace environment - air * | Concentration/content of phenolphthalein Range (0,33 – 16,7) mg/m3 Range (0,08 – 4,0) mg w próbce |
Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC UV/DAD) | PN-Z-04506:2019-10 | |
| 59 | Workplace environment - air * | Concentration/content of ethyl 2-cyanoacrylate Range (0,10 – 4,0) mg/m3 Range (0,0012 – 0,048) mg w próbce |
Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC UV/DAD) | PN-Z-04467:2016-10 | |
| 60 | Workplace environment - air * | Stężenie/zawartość N-hydroksymocznika Range (0,001 – 0,08) mg/m3 Range (0,48 – 38,4) μg w próbce |
Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC UV) | Podstawy i Metody Oceny Środowiska Pracy 2010, nr 1 (63), s. 155-162 | |
| 61 | Workplace environment - air * | Stężenie/zawartość fluorouracyl – frakcja wdychalna Range (0,00015 – 0,00733) mg/m3 Range (0,000105 – 0,00528) mg w próbce |
Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC UV) | Podstawy i Metody Oceny Środowiska Pracy 2020, nr 2 (104), s. 63-77 | |
| 62 | Workplace environment - air * | Concentration/content of acrylamide Range (0,0070 – 0,14) mg/m3 Range (0,00084 – 0,017) mg w próbce |
Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC UV) | PN-Z-04486:2017-10 | |
| 63 | Workplace environment - air * | Stężenie/zawartość hydrazyny Range (0,00125 – 0,0769) mg/m3 Range (0,00094 – 0,0568) ppm Range (0,00030 – 0,0070) mg w próbce Range (0,00023 – 0,053) ppm |
Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC UV) | PN-Z-04523:2020-12 | |
| 64 | Workplace environment - air * | Formaldehyde concentration/content Range (0,0133 – 60) mg/m3 Range (0,00040 – 0,0600) mg w próbce UV |
Metoda wysokosprawnej chromatografii cieczowej z detekcją | Podstawy i Metody Oceny Środowiska Pracy 1999, nr 22, s. 96 - 100 | |
| 65 | Workplace environment - air * | Chlorine concentration/content Range (0,12 – 8) mg/m3 Range (0,0005 – 0,008) mg w próbce |
Spectrophotometric method | PN-75/Z-04037/03 | |
| 66 | Workplace environment - air * | Hydrogen chloride concentration/content Range (0,5 – 10) mg/m3 Range (0,20 – 4,0) mg w próbce |
Turbidimetric method | PN-Z-04450:2014-08 | |
| 67 | Workplace environment - air * | Ammonia concentration/content Range (1,25– 60) mg/m3 Range (0,015 – 0,30) mg w próbce |
Spectrophotometric method | PN-Z-04041:1971 | |
| 68 | Workplace environment - air * | Concentration/content of highly refined mineral oils excluding metalworking fluids Range (0,42 – 41,7) mg/m3 Range (0,30 – 10,0) mg w próbce |
Spectrophotometric method | PN-Z-04108-6:2006 | PN-Z-04108-6:2006/Az1:2009 | |
| 69 | Wastewater | Sampling for chemical and physical testing Temperature of the collected wastewater sample Range (0,5 – 50) oC |
Manual method | PN-ISO 5667-10:2021-11 | PN-77/C-04584 | |
| 70 | Wastewater | Total suspended solids (TSS) Range (2,0 – 1000) mg/l |
Gravimetric method | PN-EN 872:2007 + Ap1:2007 | |
| 71 | Wastewater | Concentration of substances extractable with petroleum ether Range (2,0 – 100) mg/l |
Gravimetric method | EHS-PB-3 wyd. 2 z 20.08.15 | |
| 72 | Wastewater | Settleable solids Range (0,5 – 100) ml/l |
Volumetric method | PN-C-04559-03:1972 | |
| 73 | Water | Sampling for chemical and physical testing Temperature of the water sample taken Range (0,5 – 50) oC |
PN-ISO 5667-6:2016-12 | PN-77/C-04584 | ||
| 74 | Water | Total alkalinity Range (0,4 – 40) mmol/l Range (20 – 2000) mg/l CaCO3 |
Titrimetric method | PN-EN ISO 9963-1:2001+Ap1:2004 | |
| 75 | Water and wastewater | pH Range (2,0 – 12,0) |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 76 | Water and wastewater | Electrical conductivity Range (10 – 12880) μS/cm |
Conductometric method | PN-EN 27888:1999 | |
| 77 | Water and wastewater | Chloride concentration Range (5,0 – 1000) mg/I |
Titrimetric method | PN-ISO 9297:1994 | |
| 78 | Water and wastewater | Total iron concentration Range (0,01 – 20) mg/l |
Spectrophotometric method | PN-ISO 6332:2001+Ap1:2016-06 | |
| 79 | Water and wastewater | Nitrite concentration Range (0,01 – 40) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 80 | Water and wastewater | Phenol index Range (0,01 – 50) mg/l |
Spectrophotometric method | PN-ISO 6439:1994, pkt 4 | |
| 81 | Water and wastewater | Chemical oxygen demand – COD Range (10,0 – 1000) mg/I O2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 82 | Water and wastewater | Phosphate concentration Range (0,01 – 50) mg/l Range (0,03 – 153) mg/l P-PO4 |
Spectrophotometric method | PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010 | |
| 83 | Water and wastewater | Total phosphorus concentration Range (0,04 – 30) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010 | |
| 84 | Water and wastewater | Stężenie azotu amonowego, jonu amonowego ammonium nitrogen Range (0,050 – 325) mg/l ammonium ion Range (0,064 – 418) mg/l |
Spectrophotometric method | PN-ISO 7150-1:2002 | |
| 85 | Water and wastewater | Sulfate concentration Range (5 – 600) mg/l |
Turbidimetric method | EHS-PB-50 wyd. 1 z 05.06.2017 r. | na podstawie metody HACH nr 8051 | |
| 86 | Water and wastewater | Biochemical oxygen demand - BOD5 Range (1 – 6000) mg/I O2 |
Electrochemical method | PN-EN ISO 5815-1:2019-12 | |
| 87 | Water and wastewater | Mineral oil index Range (0,10 – 50) mg/I GC-FID |
Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną | PN-EN ISO 9377-2:2003 | |
| 88 | Środowisko pracy - hałas * | A-weighted equivalent sound level Maximum A-weighted sound level Range (24 - 135) dB C-weighted peak sound pressure level Range (40 - 138) dB |
Direct measurement method | PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących strategię 2 i 3 – punkt 10 i 11 | PN-N-01307:1994 | |
| 89 | Środowisko pracy - hałas * | Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated) |
PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących strategię 2 i 3 – punkt 10 i 11 | PN-N-01307:1994 | ||
| 90 | Środowisko pracy - oświetlenie miejsce pracy światłem elektrycznym * | Illuminance Range (5 – 5000) lx |
Direct measurement method | PN-83/E-04040.03 | |
| 91 | Środowisko pracy - oświetlenie miejsce pracy światłem elektrycznym * | Illuminance uniformity (calculated) | PN-83/E-04040.03 | ||
| 92 | Workplace environment - air * | Sampling for the assessment of occupational exposure to: industrial dusts inhalable fraction respirable fraction organic substances, including inhalable fraction inorganic substances, including inhalable fraction respirable fraction metals and their compounds, including inhalable fraction respirable fraction |
Personal dosimetry method | PN-Z-04008-7:2002+Az1:2004 | |
| 93 | Workplace environment - air * | Exposure index (calculated) | PN-Z-04008-7:2002+Az1:2004 | ||
| 94 | Wastewater | Sampling for chemical and physical testing Temperature of the collected wastewater sample Range (0,5 – 50) oC |
Manual method | PN-ISO 5667-10:2021-11 | PN-77/C-04584 | |
| 95 | Water | Sampling for chemical and physical testing Temperature of the water sample taken Range (0,5 – 50) oC |
PN-ISO 5667-6:2016-02 | PN-77/C-04584 | ||
| 96 | Water | Total alkalinity Range (0,4 – 40) mmol/l Range (20 – 2000) mg/l CaCO3 |
Titrimetric method | PN-EN ISO 9963-1:2001+Ap1:2004 | |
| 97 | Water | Zasadowość złożona Range (0,2 – 20) mmol/l |
Titrimetric method | PN-EN ISO 9963-1:2001+Ap1:2004 | |
| 98 | Water | Bicarbonate concentration (calculated) | PN-EN ISO 9963-1:2001+Ap1:2004 | ||
| 99 | Water | Total content of calcium and magnesium (total hardness) Range (5 – 500) mg/l CaCO3 |
Titrimetric method | PN-ISO 6059:1999 | |
| 100 | Water and wastewater | pH Range (2,0 – 12,0) |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 101 | Water and wastewater | Electrical conductivity Range (10 – 12880) μS/cm |
Conductometric method | PN-EN 27888:1999 | |
Reference standards (85)
EHS-PB-1 wyd. 5 z 17.04.2019
EHS-PB-3 wyd. 2 z 20.08.15
EHS-PB-43 wyd. 3 z 01.06.2022
EHS-PB-50 wyd. 1 z 05.06.2017 r.
NIOSH Method 1003 Issue 3 (2003)
NIOSH Method 1300 Issue 2 (1994)
NIOSH Method 1400 Issue 2 (1994)
NIOSH Method 1405 Issue 1 (2003)
NIOSH Method 1450 Issue 3 (2003) EHS-PB-10 wyd. 5 z 29.05.2019
NIOSH Method 1457 Issue 1 (1994) EHS-PB-10 wyd. 5 z 29.05.2019
NIOSH Method 1458 Issue 2 (1994) EHS-PB-10 wyd. 5 z 29.05.2019
NIOSH Method 1500 Issue 3 (2003)
NIOSH Method 1501 Issue 3 (2003)
NIOSH Method 1551 Issue 2 (1994)
NIOSH Method 2546 Issue 1:1994
PN-75/Z-04037/03
PN-77/C-04584
PN-81/Z-04134.03
PN-83/E-04040.03
PN-C-04559-03:1972
PN-EN 14253+A1:2011
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007 + Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 11079:2008
PN-EN ISO 5349-1:2004
PN-EN ISO 5349-2:2004
PN-EN ISO 5349-2:2004/A1:2015-11
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010
PN-EN ISO 7243:2018-01
PN-EN ISO 7730:2006
PN-EN ISO 7730:2006+Ap2:2016-04
PN-EN ISO 9377-2:2003
PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących strategię 2 i 3 – punkt 10 i 11
PN-EN ISO 9963-1:2001+Ap1:2004
PN-ISO 15705:2005
PN-ISO 5667-10:2021-11
PN-ISO 5667-6:2016-02
PN-ISO 5667-6:2016-12
PN-ISO 6059:1999
PN-ISO 6332:2001+Ap1:2016-06
PN-ISO 6439:1994, pkt 4
PN-ISO 7150-1:2002
PN-ISO 9297:1994
PN-N-01307:1994
PN-Z-01339:2020-12
PN-Z-04008-7:2002+Az1:2004
PN-Z-04041:1971
PN-Z-04108-6:2006
PN-Z-04108-6:2006/Az1:2009
PN-Z-04119-10:2008
PN-Z-04134-02:1981
PN-Z-04227-02:1992
PN-Z-04270:2000
PN-Z-04305:2003
PN-Z-04323:2004
PN-Z-04374:2009
PN-Z-04437:2011
PN-Z-04450:2014-08
PN-Z-04460:2014-09
PN-Z-04461:2015-10
PN-Z-04467:2016-10
PN-Z-04476:2016-10
PN-Z-04479:2016
PN-Z-04481:2017-10
PN-Z-04486:2017-10
PN-Z-04491:2017-10
PN-Z-04501:2019-10
PN-Z-04506:2019-10
PN-Z-04507:2022-05
PN-Z-04507:2022-05/Ap1:2022-08
PN-Z-04508:2022-05
PN-Z-04508:2022-05/Ap1:2022-08
PN-Z-04523:2020-12
Podstawy i Metody Oceny Środowiska Pracy 1997, nr 17, s. 55-59
Podstawy i Metody Oceny Środowiska Pracy 1999, nr 22, s. 96 - 100
Podstawy i Metody Oceny Środowiska Pracy 2007, nr 1 (51), s. 141 - 147
Podstawy i Metody Oceny Środowiska Pracy 2009, nr 1(59), s. 141–146
Podstawy i Metody Oceny Środowiska Pracy 2010, nr 1 (63), s. 155-162
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 17, s. 97-100
Podstawy i Metody Oceny Środowiska Pracy 2020, nr 2 (104), s. 63-77
Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023, poz. 1706) z wyłączeniem punktu F
na podstawie metody HACH nr 8051