{"lab":{"_id":"69ad52a3de79e566650fb64e","accr_number":"AB 1226","country":"PL","accr_body":"PCA","address":"ul. Okólna 11/69, 30-669 Kraków","categories":["environment","water"],"city":"Kraków","imported_at":"2026-03-08T10:42:43.265Z","methods_count":101,"name":"Laboratorium Badawcze EHS-LAB Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1226.pdf"],"scope_summary":"","search_text":"laboratorium badawcze ehs-lab sp. z o.o. ul. okólna 11/69, 30-669 kraków environment other metrology pharma electronics materials petro automotive food water","status":"active","updated_at":"2026-03-08T14:50:24.472Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T09:05:41.064Z","email_confidence":"high","email_mx":true,"email_source":"http://www.ehs-lab.pl/index.php/pl/ehs-lab-kontakt","parse_date":"2026-08-17T09:05:41.064Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"– C/33/P, C/30/P","pl":"Badania chemiczne i pobieranie próbek - powietrze, ścieki","en":"Chemical tests and sampling - air, sewage"},{"codes":"– N/33/P, N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek – powietrze, ścieki","en":"Tests of physical properties and sampling - air, sewage"},{"codes":"– N/28","pl":"Badania właściwości fizycznych wody","en":"Tests of physical properties of water"},{"codes":"– C/28","pl":"Badania chemiczne wody","en":"Chemical tests of water"},{"codes":"– G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe i uciążliwe – hałas, hałas ultradźwiękowy, oświetlenie, drgania, mikroklimat)","en":"Tests concerning environmental engineering (environmental and climatic) - working environment (harmful and nuisance factors noise, ultrasonic noise, lighting, vibration, microclimate)"},{"codes":"– G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko ogólne (czynniki fizyczne – hałas)","en":"Tests concerning environmental engineering (environmental and climatic) - general environment (physical factors - noise)"}],"issue":{"no":"25","date":"10.06.2026"},"map_coord":[50.016878,19.985021],"map_geo":"nominatim-street","lab_locations":[{"name":"Laboratorium Badawcze EHS-LAB Sp. z o.o.","address":"ul. Okólna 11/69","city":null,"postal":null},{"name":"Laboratorium Badawcze EHS-LAB","address":"ul. Mogilska 80, 31-546 Kraków (działalność techniczna)","city":"Kraków","postal":"31-546"}],"scope_format":"PCA::pracownie+siatka5","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/3bf228377978b30176f1b2259bcc7ca6/AB%201226.pdf","has_en":true,"category_counts":{"environment":74,"water":27,"materials":2,"construction":2,"petro":2,"automotive":1},"category_scores":{"environment":50.7,"water":6.75,"materials":0.04,"construction":0.04,"petro":0.04,"automotive":0.01},"has_zh":true},"methods":[{"_id":"6a82cee5884ede9a1b2c2e9d","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - hałas *","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(25 - 135) dB"},{"name":"Szczytowy poziom dźwięku C"},{"name":"Zakres","range":"(40 - 138) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (25 - 135) dB\nSzczytowy poziom dźwięku C\nZakres (40 - 138) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących strategię 2 i 3 – punkt 10 i 11 | PN-N-01307:1994","norm_bases":["PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących strategię 2 i 3 – punkt 10 i 11","PN-N-01307:1994"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas * Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (25 - 135) dB\nSzczytowy poziom dźwięku C\nZakres (40 - 138) dB\nMetoda pomiarowa bezpośrednia PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących strategię 2 i 3 – punkt 10 i 11 | PN-N-01307:1994 Srodowisko pracy - halas * Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres:\nZakres (25 - 135) dB\nSzczytowy poziom dzwieku C\nZakres (40 - 138) dB\nMetoda pomiarowa bezposrednia PN-EN ISO 9612:2011 z wylaczeniem metod obejmujacych strategie 2 i 3 – punkt 10 i 11 | PN-N-01307:1994","categories":["environment"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters_en":[{"name":"Range","range":"(25 - 135) dB"},{"name":"C-weighted peak sound pressure level"},{"name":"Range","range":"(40 - 138) dB"}],"search_en":"A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method Range C-weighted peak sound pressure level Range PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących strategię 2 i 3 – punkt 10 i 11 | PN-N-01307:1994","technique_en":"Direct measurement method","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(25 - 135) dB"},{"name":"C 计权峰值声级"},{"name":"范围","range":"(40 - 138) dB"}],"search_zh":"A 计权等效声级 A 计权最大声级 直接测量法 范围 C 计权峰值声级 范围 PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących strategię 2 i 3 – punkt 10 i 11 | PN-N-01307:1994","technique_zh":"直接测量法"},{"_id":"6a82cee5884ede9a1b2c2e9e","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - hałas *","methodology":"Poziom ekspozycji na hałas odniesiony do:","parameters":[{"name":"8-godz. dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących strategię 2 i 3 – punkt 10 i 11 | PN-N-01307:1994","norm_bases":["PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących strategię 2 i 3 – punkt 10 i 11","PN-N-01307:1994"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas * Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących strategię 2 i 3 – punkt 10 i 11 | PN-N-01307:1994 Srodowisko pracy - halas * Poziom ekspozycji na halas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-EN ISO 9612:2011 z wylaczeniem metod obejmujacych strategie 2 i 3 – punkt 10 i 11 | PN-N-01307:1994","categories":["environment"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Noise exposure level referred to:","parameters_en":[{"name":"an 8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"search_en":"Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated) PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących strategię 2 i 3 – punkt 10 i 11 | PN-N-01307:1994","methodology_zh":"噪声暴露级，参照：","parameters_zh":[{"name":"8 小时日工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"噪声暴露级，参照： 8 小时日工作时间 平均每周工作时间（计算值） PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących strategię 2 i 3 – punkt 10 i 11 | PN-N-01307:1994"},{"_id":"6a82cee5884ede9a1b2c2e9f","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy – hałas ultradźwiękowy *","methodology":"Równoważne poziomy ciśnienia akustycznego w pasmach","parameters":[{"name":"tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz Maksymalne poziomy ciśnienia akustycznego w pasmach"},{"name":"tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz"},{"name":"Zakres","range":"(59 – 160) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważne poziomy ciśnienia akustycznego w pasmach\nZakres:\ntercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz Maksymalne poziomy ciśnienia akustycznego w pasmach\ntercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz\nZakres (59 – 160) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-Z-01339:2020-12","norm_bases":["PN-Z-01339:2020-12"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas ultradźwiękowy * Równoważne poziomy ciśnienia akustycznego w pasmach\nZakres:\ntercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz Maksymalne poziomy ciśnienia akustycznego w pasmach\ntercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz\nZakres (59 – 160) dB\nMetoda pomiarowa bezpośrednia PN-Z-01339:2020-12 Srodowisko pracy – halas ultradzwiekowy * Rownowazne poziomy cisnienia akustycznego w pasmach\nZakres:\ntercjowych o czestotliwosciach srodkowych od 10 kHz do 40 kHz Maksymalne poziomy cisnienia akustycznego w pasmach\ntercjowych o czestotliwosciach srodkowych od 10 kHz do 40 kHz\nZakres (59 – 160) dB\nMetoda pomiarowa bezposrednia PN-Z-01339:2020-12","categories":["environment"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz Maksymalne poziomy ciśnienia akustycznego w pasmach"},{"name":"tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz"},{"name":"Range","range":"(59 – 160) dB"}],"search_en":"Direct measurement method Range PN-Z-01339:2020-12","technique_en":"Direct measurement method","parameters_zh":[{"name":"tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz Maksymalne poziomy ciśnienia akustycznego w pasmach"},{"name":"tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz"},{"name":"范围","range":"(59 – 160) dB"}],"search_zh":"直接测量法 范围 PN-Z-01339:2020-12","technique_zh":"直接测量法"},{"_id":"6a82cee5884ede9a1b2c2ea0","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy – hałas ultradźwiękowy *","methodology":"Równoważne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz odniesione do:","parameters":[{"name":"8 - godz. dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Równoważne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz odniesione do:\nZakres:\n8 - godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-Z-01339:2020-12","norm_bases":["PN-Z-01339:2020-12"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas ultradźwiękowy * Równoważne poziomy ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz odniesione do:\nZakres:\n8 - godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-Z-01339:2020-12 Srodowisko pracy – halas ultradzwiekowy * Rownowazne poziomy cisnienia akustycznego w pasmach tercjowych o czestotliwosciach srodkowych od 10 kHz do 40 kHz odniesione do:\nZakres:\n8 - godz. dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-Z-01339:2020-12","categories":["environment"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Equivalent sound pressure levels in third-octave bands with centre frequencies from 10 kHz to 40 kHz referred to:","parameters_en":[{"name":"an 8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"search_en":"Equivalent sound pressure levels in third-octave bands with centre frequencies from 10 kHz to 40 kHz referred to: an 8-hour daily working time the average weekly working time (calculated) PN-Z-01339:2020-12","parameters_zh":[{"name":"每日 8 小时工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"中心频率自 10 kHz 至 40 kHz 的1/3倍频程等效声压级，参照下列条件： 每日 8 小时工作时间 平均每周工作时间（计算值） PN-Z-01339:2020-12","methodology_zh":"中心频率自 10 kHz 至 40 kHz 的1/3倍频程等效声压级，参照下列条件："},{"_id":"6a82cee5884ede9a1b2c2ea1","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(25 – 135) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres (25 – 135) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023, poz. 1706) z wyłączeniem punktu F","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023, poz. 1706) z wyłączeniem punktu F"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A\nZakres (25 – 135) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023, poz. 1706) z wyłączeniem punktu F Srodowisko ogolne - halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A\nZakres (25 – 135) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023, poz. 1706) z wylaczeniem punktu F","categories":["environment"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level","parameters_en":[{"name":"Range","range":"(25 – 135) dB"}],"search_en":"General environment - noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level Direct measurement method Range Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023, poz. 1706) z wyłączeniem punktu F","technique_en":"Direct measurement method","test_object_en":"General environment - noise from installations, equipment and industrial plants","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(25 – 135) dB"}],"search_zh":"一般环境 — 来自装置、设备和工业企业的噪声 A 计权等效声级 直接测量法 范围 Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023, poz. 1706) z wyłączeniem punktu F","technique_zh":"直接测量法","test_object_zh":"一般环境 — 来自装置、设备和工业企业的噪声"},{"_id":"6a82cee5884ede9a1b2c2ea2","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023, poz. 1706) z wyłączeniem punktu F","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023, poz. 1706) z wyłączeniem punktu F"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023, poz. 1706) z wyłączeniem punktu F Srodowisko ogolne - halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023, poz. 1706) z wylaczeniem punktu F","categories":["environment"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","search_en":"General environment - noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023, poz. 1706) z wyłączeniem punktu F","test_object_en":"General environment - noise from installations, equipment and industrial plants","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 — 来自装置、设备和工业企业的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. 2023, poz. 1706) z wyłączeniem punktu F","test_object_zh":"一般环境 — 来自装置、设备和工业企业的噪声"},{"_id":"6a82cee5884ede9a1b2c2ea3","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - drgania o działaniu ogólnym na organizm człowieka *","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,01 – 40) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia; Metoda próbkowania","techniques":["Metoda pomiarowa bezpośrednia","Metoda próbkowania"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,01 – 40) m/s2\nMetoda pomiarowa bezpośrednia; Metoda próbkowania","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - drgania o działaniu ogólnym na organizm człowieka * Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,01 – 40) m/s2\nMetoda pomiarowa bezpośrednia; Metoda próbkowania PN-EN 14253+A1:2011 Srodowisko pracy - drgania o dzialaniu ogolnym na organizm czlowieka * Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,01 – 40) m/s2\nMetoda pomiarowa bezposrednia; Metoda probkowania PN-EN 14253+A1:2011","categories":["environment"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters_en":[{"name":"Range","range":"(0,01 – 40) m/s2"}],"search_en":"Frequency-weighted r.m.s. vibration acceleration Direct measurement method; Sampling method Range PN-EN 14253+A1:2011","technique_en":"Direct measurement method; Sampling method","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,01 – 40) m/s2"}],"search_zh":"频率计权振动加速度有效值 直接测量法；采样法 范围 PN-EN 14253+A1:2011","technique_zh":"直接测量法；采样法"},{"_id":"6a82cee5884ede9a1b2c2ea4","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - drgania o działaniu ogólnym na organizm człowieka *","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz)., Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz)., Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń)","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - drgania o działaniu ogólnym na organizm człowieka * Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz)., Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń) PN-EN 14253+A1:2011 Srodowisko pracy - drgania o dzialaniu ogolnym na organizm czlowieka * Ekspozycja dzienna, wyrazona w postaci rownowaznego energetycznie dla 8-godzin dzialania skutecznego, skorygowanego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4awx, 1.4awy, awz)., Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci skutecznego, wazonego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4awx, 1.4awy, awz) (z obliczen) PN-EN 14253+A1:2011","categories":["environment"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Daily exposure, expressed as the 8-hour energy-equivalent frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1.4awx, 1.4awy, awz)., Exposure lasting 30 minutes and less, expressed as the frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1.4awx, 1.4awy, awz) (calculated)","search_en":"Daily exposure, expressed as the 8-hour energy-equivalent frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1.4awx, 1.4awy, awz)., Exposure lasting 30 minutes and less, expressed as the frequency-weighted RMS vibration acceleration dominant among the vibration accelerations determined for the three directional components taking into account the appropriate coefficients (1.4awx, 1.4awy, awz) (calculated) PN-EN 14253+A1:2011"},{"_id":"6a82cee5884ede9a1b2c2ea5","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - drgania przenoszone przez kończyny górne *","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,06 – 60) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,06 – 60) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - drgania przenoszone przez kończyny górne * Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,06 – 60) m/s2\nMetoda pomiarowa bezpośrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy - drgania przenoszone przez konczyny gorne * Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,06 – 60) m/s2\nMetoda pomiarowa bezposrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters_en":[{"name":"Range","range":"(0,06 – 60) m/s2"}],"search_en":"Frequency-weighted r.m.s. vibration acceleration Direct measurement method Range PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","technique_en":"Direct measurement method","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,06 – 60) m/s2"}],"search_zh":"频率计权振动加速度有效值 直接测量法 范围 PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","technique_zh":"直接测量法"},{"_id":"6a82cee5884ede9a1b2c2ea6","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - drgania przenoszone przez kończyny górne *","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz)., Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych. (ahwx, ahwy, ahwz). (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz)., Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych. (ahwx, ahwy, ahwz). (z obliczeń)","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - drgania przenoszone przez kończyny górne * Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz)., Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych. (ahwx, ahwy, ahwz). (z obliczeń) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy - drgania przenoszone przez konczyny gorne * Ekspozycja dzienna, wyrazona w postaci rownowaznej energetycznie dla 8-godzin dzialania sumy wektorowej skutecznych, skorygowanych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz)., Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci sumy wektorowej skutecznych, wazonych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych. (ahwx, ahwy, ahwz). (z obliczen) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a82cee5884ede9a1b2c2ea7","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat zimny *","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(-10 – 10) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(-10 – 10) °C"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(25 – 75) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 – 5) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (-10 – 10) °C\nTemperatura poczernionej kuli\nZakres (-10 – 10) °C\nWilgotność powietrza\nZakres (25 – 75) %\nPrędkość powietrza\nZakres (0,15 – 5) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat zimny * Temperatura powietrza\nZakres:\nZakres (-10 – 10) °C\nTemperatura poczernionej kuli\nZakres (-10 – 10) °C\nWilgotność powietrza\nZakres (25 – 75) %\nPrędkość powietrza\nZakres (0,15 – 5) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 11079:2008 Srodowisko pracy - mikroklimat zimny * Temperatura powietrza\nZakres:\nZakres (-10 – 10) °C\nTemperatura poczernionej kuli\nZakres (-10 – 10) °C\nWilgotnosc powietrza\nZakres (25 – 75) %\nPredkosc powietrza\nZakres (0,15 – 5) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 11079:2008","categories":["environment"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(-10 – 10) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(-10 – 10) °C"},{"name":"Air humidity"},{"name":"Range","range":"(25 – 75) %"},{"name":"Air velocity"},{"name":"Range","range":"(0,15 – 5) m/s"}],"search_en":"Air temperature Direct measurement method Range Black globe temperature Range Air humidity Range Air velocity Range PN-EN ISO 11079:2008","technique_en":"Direct measurement method","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(-10 – 10) °C"},{"name":"黑球温度"},{"name":"范围","range":"(-10 – 10) °C"},{"name":"空气湿度"},{"name":"范围","range":"(25 – 75) %"},{"name":"空气流速"},{"name":"范围","range":"(0,15 – 5) m/s"}],"search_zh":"空气温度 直接测量法 范围 黑球温度 范围 空气湿度 范围 空气流速 范围 PN-EN ISO 11079:2008","technique_zh":"直接测量法"},{"_id":"6a82cee5884ede9a1b2c2ea8","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat zimny *","methodology":"Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń)","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat zimny * Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń) PN-EN ISO 11079:2008 Srodowisko pracy - mikroklimat zimny * Wskaznik IREQmin, Wskaznik IREQneutral, Wskaznik twc (z obliczen) PN-EN ISO 11079:2008","categories":["environment"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"IREQmin index, IREQneutral index, twc index (calculated)","search_en":"IREQmin index, IREQneutral index, twc index (calculated) PN-EN ISO 11079:2008","methodology_zh":"IREQmin 指数、IREQneutral 指数、twc 指数（计算值）","search_zh":"IREQmin 指数、IREQneutral 指数、twc 指数（计算值） PN-EN ISO 11079:2008"},{"_id":"6a82cee5884ede9a1b2c2ea9","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat umiarkowany *","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(10 – 40) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(10 – 40) °C"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(25 – 75) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 – 5) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (10 – 40) °C\nTemperatura poczernionej kuli\nZakres (10 – 40) °C\nWilgotność powietrza\nZakres (25 – 75) %\nPrędkość powietrza\nZakres (0,15 – 5) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006+Ap2:2016-04","norm_bases":["PN-EN ISO 7730:2006","PN-EN ISO 7730:2006+Ap2:2016-04"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat umiarkowany * Temperatura powietrza\nZakres:\nZakres (10 – 40) °C\nTemperatura poczernionej kuli\nZakres (10 – 40) °C\nWilgotność powietrza\nZakres (25 – 75) %\nPrędkość powietrza\nZakres (0,15 – 5) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006+Ap2:2016-04 Srodowisko pracy - mikroklimat umiarkowany * Temperatura powietrza\nZakres:\nZakres (10 – 40) °C\nTemperatura poczernionej kuli\nZakres (10 – 40) °C\nWilgotnosc powietrza\nZakres (25 – 75) %\nPredkosc powietrza\nZakres (0,15 – 5) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006+Ap2:2016-04","categories":["environment"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(10 – 40) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(10 – 40) °C"},{"name":"Air humidity"},{"name":"Range","range":"(25 – 75) %"},{"name":"Air velocity"},{"name":"Range","range":"(0,15 – 5) m/s"}],"search_en":"Workplace environment - moderate microclimate * Air temperature Direct measurement method Range Black globe temperature Range Air humidity Range Air velocity Range PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006+Ap2:2016-04","technique_en":"Direct measurement method","test_object_en":"Workplace environment - moderate microclimate *","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(10 – 40) °C"},{"name":"黑球温度"},{"name":"范围","range":"(10 – 40) °C"},{"name":"空气湿度"},{"name":"范围","range":"(25 – 75) %"},{"name":"空气流速"},{"name":"范围","range":"(0,15 – 5) m/s"}],"search_zh":"空气温度 直接测量法 范围 黑球温度 范围 空气湿度 范围 空气流速 范围 PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006+Ap2:2016-04","technique_zh":"直接测量法"},{"_id":"6a82cee5884ede9a1b2c2eaa","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat umiarkowany *","methodology":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","reference":"PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006+Ap2:2016-04","norm_bases":["PN-EN ISO 7730:2006","PN-EN ISO 7730:2006+Ap2:2016-04"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat umiarkowany * Wskaźnik PMV, Wskaźnik PPD (z obliczeń) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006+Ap2:2016-04 Srodowisko pracy - mikroklimat umiarkowany * Wskaznik PMV, Wskaznik PPD (z obliczen) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006+Ap2:2016-04","categories":["environment"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"PMV index, PPD index (calculated)","search_en":"Workplace environment - moderate microclimate * PMV index, PPD index (calculated) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006+Ap2:2016-04","test_object_en":"Workplace environment - moderate microclimate *","methodology_zh":"PMV 指数、PPD 指数（计算值）","search_zh":"PMV 指数、PPD 指数（计算值） PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006+Ap2:2016-04"},{"_id":"6a82cee5884ede9a1b2c2eab","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat gorący *","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(15 – 40) °C"},{"name":"Temperatura wilgotna naturalna"},{"name":"Zakres","range":"(15 – 40) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(15 – 50) °C"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (15 – 40) °C\nTemperatura wilgotna naturalna\nZakres (15 – 40) °C\nTemperatura poczernionej kuli\nZakres (15 – 50) °C\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7243:2018-01","norm_bases":["PN-EN ISO 7243:2018-01"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat gorący * Temperatura powietrza\nZakres:\nZakres (15 – 40) °C\nTemperatura wilgotna naturalna\nZakres (15 – 40) °C\nTemperatura poczernionej kuli\nZakres (15 – 50) °C\nMetoda pomiarowa bezpośrednia PN-EN ISO 7243:2018-01 Srodowisko pracy - mikroklimat goracy * Temperatura powietrza\nZakres:\nZakres (15 – 40) °C\nTemperatura wilgotna naturalna\nZakres (15 – 40) °C\nTemperatura poczernionej kuli\nZakres (15 – 50) °C\nMetoda pomiarowa bezposrednia PN-EN ISO 7243:2018-01","categories":["environment"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(15 – 40) °C"},{"name":"Natural wet bulb temperature"},{"name":"Range","range":"(15 – 40) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(15 – 50) °C"}],"search_en":"Air temperature Direct measurement method Range Natural wet bulb temperature Range Black globe temperature Range PN-EN ISO 7243:2018-01","technique_en":"Direct measurement method","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(15 – 40) °C"},{"name":"自然湿球温度"},{"name":"范围","range":"(15 – 40) °C"},{"name":"黑球温度"},{"name":"范围","range":"(15 – 50) °C"}],"search_zh":"空气温度 直接测量法 范围 自然湿球温度 范围 黑球温度 范围 PN-EN ISO 7243:2018-01","technique_zh":"直接测量法"},{"_id":"6a82cee5884ede9a1b2c2eac","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat gorący *","methodology":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","reference":"PN-EN ISO 7243:2018-01","norm_bases":["PN-EN ISO 7243:2018-01"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat gorący * Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń) PN-EN ISO 7243:2018-01 Srodowisko pracy - mikroklimat goracy * Wskaznik WBGT, Wskaznik WBGTeff (z obliczen) PN-EN ISO 7243:2018-01","categories":["environment"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"WBGT index, WBGTeff index (calculated)","search_en":"WBGT index, WBGTeff index (calculated) PN-EN ISO 7243:2018-01","methodology_zh":"WBGT 指数、WBGTeff 指数（计算值）","search_zh":"WBGT 指数、WBGTeff 指数（计算值） PN-EN ISO 7243:2018-01"},{"_id":"6a82cee5884ede9a1b2c2ead","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne we wnętrzach *","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(5 – 5000) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (5 – 5000) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie elektryczne we wnętrzach * Natężenie oświetlenia\nZakres (5 – 5000) lx\nMetoda pomiarowa bezpośrednia PN-83/E-04040.03 Srodowisko pracy - oswietlenie elektryczne we wnetrzach * Natezenie oswietlenia\nZakres (5 – 5000) lx\nMetoda pomiarowa bezposrednia PN-83/E-04040.03","categories":["environment"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance","parameters_en":[{"name":"Range","range":"(5 – 5000) lx"}],"search_en":"Workplace environment - indoor electric lighting * Illuminance Direct measurement method Range PN-83/E-04040.03","technique_en":"Direct measurement method","test_object_en":"Workplace environment - indoor electric lighting *","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(5 – 5000) lx"}],"search_zh":"照度 直接测量法 范围 PN-83/E-04040.03","technique_zh":"直接测量法"},{"_id":"6a82cee5884ede9a1b2c2eae","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne we wnętrzach *","methodology":"Równomierność oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie elektryczne we wnętrzach * Równomierność oświetlenia (z obliczeń) PN-83/E-04040.03 Srodowisko pracy - oswietlenie elektryczne we wnetrzach * Rownomiernosc oswietlenia (z obliczen) PN-83/E-04040.03","categories":["environment"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance uniformity (calculated)","search_en":"Workplace environment - indoor electric lighting * Illuminance uniformity (calculated) PN-83/E-04040.03","test_object_en":"Workplace environment - indoor electric lighting *","methodology_zh":"照度均匀度（计算值）","search_zh":"照度均匀度（计算值） PN-83/E-04040.03"},{"_id":"6a82cee5884ede9a1b2c2eaf","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - powietrze *","methodology":"Stężenie gazów:","parameters":[{"name":"CO","range":"(2,3 – 200) mg/m3"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie gazów:\nCO (2,3 – 200) mg/m3\nMetoda elektrochemiczna","reference":"EHS-PB-43 wyd. 3 z 01.06.2022","norm_bases":["EHS-PB-43 wyd. 3 z 01.06.2022"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze * Stężenie gazów:\nCO (2,3 – 200) mg/m3\nMetoda elektrochemiczna EHS-PB-43 wyd. 3 z 01.06.2022 Srodowisko pracy - powietrze * Stezenie gazow:\nCO (2,3 – 200) mg/m3\nMetoda elektrochemiczna EHS-PB-43 wyd. 3 z 01.06.2022","categories":["environment"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gas concentrations:","parameters_en":[{"name":"CO","range":"(2,3 – 200) mg/m3"}],"search_en":"Workplace environment - air * Gas concentrations: Electrochemical method CO EHS-PB-43 wyd. 3 z 01.06.2022","technique_en":"Electrochemical method","test_object_en":"Workplace environment - air *","search_zh":"工作环境 － 空气 * 气体浓度： 电化学法 CO EHS-PB-43 wyd. 3 z 01.06.2022","technique_zh":"电化学法","parameters_zh":[{"name":"CO","range":"(2,3 – 200) mg/m3"}],"methodology_zh":"气体浓度：","test_object_zh":"工作环境 － 空气 *"},{"_id":"6a82cee5884ede9a1b2c2eb0","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - powietrze *","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"EHS-PB-43 wyd. 3 z 01.06.2022","norm_bases":["EHS-PB-43 wyd. 3 z 01.06.2022"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze * Wskaźnik narażenia (z obliczeń) EHS-PB-43 wyd. 3 z 01.06.2022 Srodowisko pracy - powietrze * Wskaznik narazenia (z obliczen) EHS-PB-43 wyd. 3 z 01.06.2022","categories":["environment"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Exposure index (calculated)","search_en":"Workplace environment - air * Exposure index (calculated) EHS-PB-43 wyd. 3 z 01.06.2022","test_object_en":"Workplace environment - air *","methodology_zh":"暴露指数（计算得出）","search_zh":"工作环境 － 空气 * 暴露指数（计算得出） EHS-PB-43 wyd. 3 z 01.06.2022","test_object_zh":"工作环境 － 空气 *"},{"_id":"6a82cee5884ede9a1b2c2eb1","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - powietrze *","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","parameters":[{"name":"czynniki pyłowe"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe\nfrakcja wdychalna\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze * Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe\nfrakcja wdychalna\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy - powietrze * Pobieranie probek do oceny narazenia zawodowego na:\nZakres:\nczynniki pylowe\nfrakcja wdychalna\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004","categories":["environment"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"dust agents"},{"name":"inhalable fraction"},{"name":"respirable fraction"}],"search_en":"Workplace environment - air * Sampling for the assessment of occupational exposure to: Personal dosimetry method dust agents inhalable fraction respirable fraction PN-Z-04008-7:2002+Az1:2004","technique_en":"Personal dosimetry method","test_object_en":"Workplace environment - air *","methodology_zh":"职业接触评估采样，针对：","parameters_zh":[{"name":"粉尘因素"},{"name":"可吸入组分"},{"name":"呼吸性组分"}],"search_zh":"工作环境 － 空气 * 职业接触评估采样，针对： 个体剂量测定法 粉尘因素 可吸入组分 呼吸性组分 PN-Z-04008-7:2002+Az1:2004","technique_zh":"个体剂量测定法","test_object_zh":"工作环境 － 空气 *"},{"_id":"6a82cee5884ede9a1b2c2eb2","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - powietrze *","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","parameters":[{"name":"substancje organiczne, w tym"},{"name":"frakcja wdychalna"},{"name":"substancje nieorganiczne, w tym"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"},{"name":"frakcja torakalna"},{"name":"metale i ich związki, w tym"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"}],"technique":"Metoda dozymetrii indywidualnej; Metoda stacjonarna","techniques":["Metoda dozymetrii indywidualnej","Metoda stacjonarna"],"computed":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nsubstancje organiczne, w tym\nfrakcja wdychalna\nsubstancje nieorganiczne, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nfrakcja torakalna\nmetale i ich związki, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej; Metoda stacjonarna","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze * Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nsubstancje organiczne, w tym\nfrakcja wdychalna\nsubstancje nieorganiczne, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nfrakcja torakalna\nmetale i ich związki, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej; Metoda stacjonarna PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy - powietrze * Pobieranie probek do oceny narazenia zawodowego na:\nZakres:\nsubstancje organiczne, w tym\nfrakcja wdychalna\nsubstancje nieorganiczne, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nfrakcja torakalna\nmetale i ich zwiazki, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej; Metoda stacjonarna PN-Z-04008-7:2002+Az1:2004","categories":["materials","environment"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"organic substances, including"},{"name":"inhalable fraction"},{"name":"inorganic substances, including"},{"name":"inhalable fraction"},{"name":"respirable fraction"},{"name":"thoracic fraction"},{"name":"metals and their compounds, including"},{"name":"inhalable fraction"},{"name":"respirable fraction"}],"search_en":"Workplace environment - air * Sampling for the assessment of occupational exposure to: Personal dosimetry method; Stationary method organic substances, including inhalable fraction inorganic substances, including inhalable fraction respirable fraction thoracic fraction metals and their compounds, including inhalable fraction respirable fraction PN-Z-04008-7:2002+Az1:2004","technique_en":"Personal dosimetry method; Stationary method","test_object_en":"Workplace environment - air *","methodology_zh":"职业接触评估采样，针对：","parameters_zh":[{"name":"有机物质，包括"},{"name":"可吸入组分"},{"name":"无机物质，包括"},{"name":"可吸入组分"},{"name":"呼吸性组分"},{"name":"胸腔组分"},{"name":"金属及其化合物，包括"},{"name":"可吸入组分"},{"name":"呼吸性组分"}],"search_zh":"工作环境 － 空气 * 职业接触评估采样，针对： 个体剂量测定法；定点测定法 有机物质，包括 可吸入组分 无机物质，包括 可吸入组分 呼吸性组分 胸腔组分 金属及其化合物，包括 可吸入组分 呼吸性组分 PN-Z-04008-7:2002+Az1:2004","technique_zh":"个体剂量测定法；定点测定法","test_object_zh":"工作环境 － 空气 *"},{"_id":"6a82cee5884ede9a1b2c2eb3","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - powietrze *","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze * Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy - powietrze * Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002+Az1:2004","categories":["environment"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Exposure index (calculated)","search_en":"Workplace environment - air * Exposure index (calculated) PN-Z-04008-7:2002+Az1:2004","test_object_en":"Workplace environment - air *","methodology_zh":"暴露指数（计算得出）","search_zh":"工作环境 － 空气 * 暴露指数（计算得出） PN-Z-04008-7:2002+Az1:2004","test_object_zh":"工作环境 － 空气 *"},{"_id":"6a82cee5884ede9a1b2c2eb4","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - powietrze *","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna","parameters":[{"name":"apatyty i fosforyty"},{"name":"cement portlandzki"},{"name":"ditlenek tytanu"},{"name":"grafit naturalny"},{"name":"grafit syntetyczny"},{"name":"kaolin"},{"name":"krzemionka bezpostaciowa i syntetyczna"},{"name":"pyły drewna"},{"name":"pyły mąki"},{"name":"pyły niesklasyfikowane ze względu na toksyczność"},{"name":"pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"sadza techniczna"},{"name":"siarczan (VI) wapnia (gips)"},{"name":"talk"},{"name":"węgiel (kamienny, brunatny)"},{"name":"węglan magnezu wapnia (dolomit)"},{"name":"węglik krzemu, niewłóknisty"},{"name":"Zakres","range":"(0,5 – 68,0) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna\nZakres:\napatyty i fosforyty\ncement portlandzki\nditlenek tytanu\ngrafit naturalny\ngrafit syntetyczny\nkaolin\nkrzemionka bezpostaciowa i syntetyczna\npyły drewna\npyły mąki\npyły niesklasyfikowane ze względu na toksyczność\npyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nsadza techniczna\nsiarczan (VI) wapnia (gips)\ntalk\nwęgiel (kamienny, brunatny)\nwęglan magnezu wapnia (dolomit)\nwęglik krzemu, niewłóknisty\nZakres (0,5 – 68,0) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05","PN-Z-04507:2022-05/Ap1:2022-08"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze * Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna\nZakres:\napatyty i fosforyty\ncement portlandzki\nditlenek tytanu\ngrafit naturalny\ngrafit syntetyczny\nkaolin\nkrzemionka bezpostaciowa i syntetyczna\npyły drewna\npyły mąki\npyły niesklasyfikowane ze względu na toksyczność\npyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nsadza techniczna\nsiarczan (VI) wapnia (gips)\ntalk\nwęgiel (kamienny, brunatny)\nwęglan magnezu wapnia (dolomit)\nwęglik krzemu, niewłóknisty\nZakres (0,5 – 68,0) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 Srodowisko pracy - powietrze * Stezenie pylowych czynnikow szkodliwych dla zdrowia – frakcja wdychalna\nZakres:\napatyty i fosforyty\ncement portlandzki\nditlenek tytanu\ngrafit naturalny\ngrafit syntetyczny\nkaolin\nkrzemionka bezpostaciowa i syntetyczna\npyly drewna\npyly maki\npyly niesklasyfikowane ze wzgledu na toksycznosc\npyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nsadza techniczna\nsiarczan (VI) wapnia (gips)\ntalk\nwegiel (kamienny, brunatny)\nweglan magnezu wapnia (dolomit)\nweglik krzemu, niewloknisty\nZakres (0,5 – 68,0) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of harmful dust agents – inhalable fraction","parameters_en":[{"name":"apatites and phosphorites"},{"name":"portland cement"},{"name":"titanium dioxide"},{"name":"natural graphite"},{"name":"synthetic graphite"},{"name":"kaolin"},{"name":"amorphous and synthetic silica"},{"name":"wood dusts"},{"name":"flour dusts"},{"name":"dusts not classified according to toxicity"},{"name":"organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"carbon black"},{"name":"calcium sulfate (VI) (gypsum)"},{"name":"talc"},{"name":"coal (hard, brown)"},{"name":"calcium magnesium carbonate (dolomite)"},{"name":"silicon carbide, non-fibrous"},{"name":"Range","range":"(0,5 – 68,0) mg/m3"}],"search_en":"Workplace environment - air * Concentration of harmful dust agents – inhalable fraction Gravimetric method apatites and phosphorites portland cement titanium dioxide natural graphite synthetic graphite kaolin amorphous and synthetic silica wood dusts flour dusts dusts not classified according to toxicity organic dusts of animal and plant origin, excluding wood and flour dusts carbon black calcium sulfate (VI) (gypsum) talc coal (hard, brown) calcium magnesium carbonate (dolomite) silicon carbide, non-fibrous Range PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment - air *","parameters_zh":[{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"二氧化钛"},{"name":"天然石墨"},{"name":"合成石墨"},{"name":"高岭土"},{"name":"无定形与合成二氧化硅"},{"name":"木粉尘"},{"name":"面粉粉尘"},{"name":"未按毒性分类的粉尘"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"炭黑"},{"name":"硫酸钙（VI）（石膏）"},{"name":"滑石"},{"name":"煤（烟煤、褐煤）"},{"name":"碳酸钙镁（白云石）"},{"name":"碳化硅，非纤维状"},{"name":"范围","range":"(0,5 – 68,0) mg/m3"}],"search_zh":"工作环境 － 空气 * 有害粉尘因素浓度 — 可吸入组分 重量法 磷灰石与磷块岩 硅酸盐水泥 二氧化钛 天然石墨 合成石墨 高岭土 无定形与合成二氧化硅 木粉尘 面粉粉尘 未按毒性分类的粉尘 动植物来源有机粉尘，木粉和面粉除外 炭黑 硫酸钙（VI）（石膏） 滑石 煤（烟煤、褐煤） 碳酸钙镁（白云石） 碳化硅，非纤维状 范围 PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_zh":"重量法","methodology_zh":"有害粉尘因素浓度 — 可吸入组分","test_object_zh":"工作环境 － 空气 *"},{"_id":"6a82cee5884ede9a1b2c2eb5","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - powietrze *","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna","parameters":[{"name":"apatyty i fosforyty"},{"name":"cement portlandzki"},{"name":"grafit naturalny"},{"name":"krzemionka bezpostaciowa i syntetyczna"},{"name":"pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"talk"},{"name":"węgiel (kamienny, brunatny)"},{"name":"Zakres","range":"(0,3 – 14,6) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna\nZakres:\napatyty i fosforyty\ncement portlandzki\ngrafit naturalny\nkrzemionka bezpostaciowa i syntetyczna\npyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\ntalk\nwęgiel (kamienny, brunatny)\nZakres (0,3 – 14,6) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04508:2022-05","PN-Z-04508:2022-05/Ap1:2022-08"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze * Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna\nZakres:\napatyty i fosforyty\ncement portlandzki\ngrafit naturalny\nkrzemionka bezpostaciowa i syntetyczna\npyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\ntalk\nwęgiel (kamienny, brunatny)\nZakres (0,3 – 14,6) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 Srodowisko pracy - powietrze * Stezenie pylowych czynnikow szkodliwych dla zdrowia – frakcja respirabilna\nZakres:\napatyty i fosforyty\ncement portlandzki\ngrafit naturalny\nkrzemionka bezpostaciowa i syntetyczna\npyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\ntalk\nwegiel (kamienny, brunatny)\nZakres (0,3 – 14,6) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of harmful dust agents – respirable fraction","parameters_en":[{"name":"apatites and phosphorites"},{"name":"portland cement"},{"name":"natural graphite"},{"name":"amorphous and synthetic silica"},{"name":"organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"talc"},{"name":"coal (hard, brown)"},{"name":"Range","range":"(0,3 – 14,6) mg/m3"}],"search_en":"Workplace environment - air * Concentration of harmful dust agents – respirable fraction Gravimetric method apatites and phosphorites portland cement natural graphite amorphous and synthetic silica organic dusts of animal and plant origin, excluding wood and flour dusts talc coal (hard, brown) Range PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment - air *","parameters_zh":[{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"天然石墨"},{"name":"无定形与合成二氧化硅"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"滑石"},{"name":"煤（烟煤、褐煤）"},{"name":"范围","range":"(0,3 – 14,6) mg/m3"}],"search_zh":"工作环境 － 空气 * 有害粉尘因素浓度 — 呼吸性组分 重量法 磷灰石与磷块岩 硅酸盐水泥 天然石墨 无定形与合成二氧化硅 动植物来源有机粉尘，木粉和面粉除外 滑石 煤（烟煤、褐煤） 范围 PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_zh":"重量法","methodology_zh":"有害粉尘因素浓度 — 呼吸性组分","test_object_zh":"工作环境 － 空气 *"},{"_id":"6a82cee5884ede9a1b2c2eb6","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - powietrze *","methodology":"Stężenie/zawartość acetonitrylu, N,N-dimetyloformamidu","parameters":[{"name":"acetonitryl:","range":"(2,2 – 250) mg/m3"},{"name":"Zakres","range":"(0,04 – 0,88) mg w próbce"},{"name":"N,N-dimetyloformamid:","range":"(0,5 – 60) mg/m3"},{"name":"(0,09 – 1,8) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC –FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC –FID)"],"computed":[],"activity":"Stężenie/zawartość acetonitrylu, N,N-dimetyloformamidu\nZakres:\nacetonitryl: (2,2 – 250) mg/m3\nZakres (0,04 – 0,88) mg w próbce\nN,N-dimetyloformamid: (0,5 – 60) mg/m3\n(0,09 – 1,8) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC –FID)","reference":"EHS-PB-1 wyd. 5 z 17.04.2019","norm_bases":["EHS-PB-1 wyd. 5 z 17.04.2019"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze * Stężenie/zawartość acetonitrylu, N,N-dimetyloformamidu\nZakres:\nacetonitryl: (2,2 – 250) mg/m3\nZakres (0,04 – 0,88) mg w próbce\nN,N-dimetyloformamid: (0,5 – 60) mg/m3\n(0,09 – 1,8) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC –FID) EHS-PB-1 wyd. 5 z 17.04.2019 Srodowisko pracy - powietrze * Stezenie/zawartosc acetonitrylu, N,N-dimetyloformamidu\nZakres:\nacetonitryl: (2,2 – 250) mg/m3\nZakres (0,04 – 0,88) mg w probce\nN,N-dimetyloformamid: (0,5 – 60) mg/m3\n(0,09 – 1,8) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC –FID) EHS-PB-1 wyd. 5 z 17.04.2019","categories":["environment"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"acetonitryl:","range":"(2,2 – 250) mg/m3"},{"name":"Range","range":"(0,04 – 0,88) mg w próbce"},{"name":"N,N-dimetyloformamid:","range":"(0,5 – 60) mg/m3"},{"name":"(0,09 – 1,8) mg w próbce"}],"search_en":"Workplace environment - air * Range EHS-PB-1 wyd. 5 z 17.04.2019","test_object_en":"Workplace environment - air *","parameters_zh":[{"name":"acetonitryl:","range":"(2,2 – 250) mg/m3"},{"name":"范围","range":"(0,04 – 0,88) mg w próbce"},{"name":"N,N-dimetyloformamid:","range":"(0,5 – 60) mg/m3"},{"name":"(0,09 – 1,8) mg w próbce"}],"search_zh":"工作环境 － 空气 * 范围 EHS-PB-1 wyd. 5 z 17.04.2019","test_object_zh":"工作环境 － 空气 *"},{"_id":"6a82cee5884ede9a1b2c2eb7","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - powietrze *","methodology":"Stężenie/zawartość n-heksanu, n-heptanu","parameters":[{"name":"n-heksan","range":"(5,0 – 200) mg/m3"},{"name":"Zakres","range":"(0,03 – 1,2) mg w próbce"},{"name":"n-heptan","range":"(66,7 – 2667) mg/m3"},{"name":"(0,40 – 16,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC –FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC –FID)"],"computed":[],"activity":"Stężenie/zawartość n-heksanu, n-heptanu\nZakres:\nn-heksan (5,0 – 200) mg/m3\nZakres (0,03 – 1,2) mg w próbce\nn-heptan (66,7 – 2667) mg/m3\n(0,40 – 16,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC –FID)","reference":"NIOSH Method 1500 Issue 3 (2003)","norm_bases":["NIOSH Method 1500 Issue 3 (2003)"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze * Stężenie/zawartość n-heksanu, n-heptanu\nZakres:\nn-heksan (5,0 – 200) mg/m3\nZakres (0,03 – 1,2) mg w próbce\nn-heptan (66,7 – 2667) mg/m3\n(0,40 – 16,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC –FID) NIOSH Method 1500 Issue 3 (2003) Srodowisko pracy - powietrze * Stezenie/zawartosc n-heksanu, n-heptanu\nZakres:\nn-heksan (5,0 – 200) mg/m3\nZakres (0,03 – 1,2) mg w probce\nn-heptan (66,7 – 2667) mg/m3\n(0,40 – 16,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC –FID) NIOSH Method 1500 Issue 3 (2003)","categories":["environment"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"n-hexane","range":"(5,0 – 200) mg/m3"},{"name":"Range","range":"(0,03 – 1,2) mg w próbce"},{"name":"n-heptane","range":"(66,7 – 2667) mg/m3"},{"name":"(0,40 – 16,0) mg w próbce"}],"search_en":"Workplace environment - air * n-hexane Range n-heptane NIOSH Method 1500 Issue 3 (2003)","test_object_en":"Workplace environment - air *","parameters_zh":[{"name":"正己烷","range":"(5,0 – 200) mg/m3"},{"name":"范围","range":"(0,03 – 1,2) mg w próbce"},{"name":"n-heptan","range":"(66,7 – 2667) mg/m3"},{"name":"(0,40 – 16,0) mg w próbce"}],"search_zh":"工作环境 － 空气 * 正己烷 范围 NIOSH Method 1500 Issue 3 (2003)","test_object_zh":"工作环境 － 空气 *"},{"_id":"6a82cee5884ede9a1b2c2eb8","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - powietrze *","methodology":"Stężenie/zawartość etanolu, propan-2-olu","parameters":[{"name":"etanol","range":"(180 – 4050) mg/m3"},{"name":"Zakres","range":"(0,18 – 4,05) mg w próbce"},{"name":"propan-2-ol","range":"(80 – 1800) mg/m3"},{"name":"(0,24 – 5,40) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC –FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC –FID)"],"computed":[],"activity":"Stężenie/zawartość etanolu, propan-2-olu\nZakres:\netanol (180 – 4050) mg/m3\nZakres (0,18 – 4,05) mg w próbce\npropan-2-ol (80 – 1800) mg/m3\n(0,24 – 5,40) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC –FID)","reference":"NIOSH Method 1400 Issue 2 (1994)","norm_bases":["NIOSH Method 1400 Issue 2 (1994)"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze * Stężenie/zawartość etanolu, propan-2-olu\nZakres:\netanol (180 – 4050) mg/m3\nZakres (0,18 – 4,05) mg w próbce\npropan-2-ol (80 – 1800) mg/m3\n(0,24 – 5,40) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC –FID) NIOSH Method 1400 Issue 2 (1994) Srodowisko pracy - powietrze * Stezenie/zawartosc etanolu, propan-2-olu\nZakres:\netanol (180 – 4050) mg/m3\nZakres (0,18 – 4,05) mg w probce\npropan-2-ol (80 – 1800) mg/m3\n(0,24 – 5,40) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC –FID) NIOSH Method 1400 Issue 2 (1994)","categories":["environment"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"ethanol","range":"(180 – 4050) mg/m3"},{"name":"Range","range":"(0,18 – 4,05) mg w próbce"},{"name":"propan-2-ol","range":"(80 – 1800) mg/m3"},{"name":"(0,24 – 5,40) mg w próbce"}],"search_en":"Workplace environment - air * ethanol Range propan-2-ol NIOSH Method 1400 Issue 2 (1994)","test_object_en":"Workplace environment - air *","parameters_zh":[{"name":"乙醇","range":"(180 – 4050) mg/m3"},{"name":"范围","range":"(0,18 – 4,05) mg w próbce"},{"name":"异丙醇","range":"(80 – 1800) mg/m3"},{"name":"(0,24 – 5,40) mg w próbce"}],"search_zh":"工作环境 － 空气 * 乙醇 范围 异丙醇 NIOSH Method 1400 Issue 2 (1994)","test_object_zh":"工作环境 － 空气 *"},{"_id":"6a82cee5884ede9a1b2c2eb9","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - powietrze *","methodology":"Stężenie/zawartość tetrahydrofuranu","parameters":[{"name":"Zakres","range":"(15 – 300) mg/m3"},{"name":"Zakres","range":"(0,075 – 1,5) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC –FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC –FID)"],"computed":[],"activity":"Stężenie/zawartość tetrahydrofuranu\nZakres:\nZakres (15 – 300) mg/m3\nZakres (0,075 – 1,5) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC –FID)","reference":"PN-Z-04481:2017-10","norm_bases":["PN-Z-04481:2017-10"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze * Stężenie/zawartość tetrahydrofuranu\nZakres:\nZakres (15 – 300) mg/m3\nZakres (0,075 – 1,5) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC –FID) PN-Z-04481:2017-10 Srodowisko pracy - powietrze * Stezenie/zawartosc tetrahydrofuranu\nZakres:\nZakres (15 – 300) mg/m3\nZakres (0,075 – 1,5) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC –FID) PN-Z-04481:2017-10","categories":["environment"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of tetrahydrofuran","parameters_en":[{"name":"Range","range":"(15 – 300) mg/m3"},{"name":"Range","range":"(0,075 – 1,5) mg w próbce"}],"search_en":"Workplace environment - air * Concentration/content of tetrahydrofuran Range Range PN-Z-04481:2017-10","test_object_en":"Workplace environment - air *","parameters_zh":[{"name":"范围","range":"(15 – 300) mg/m3"},{"name":"范围","range":"(0,075 – 1,5) mg w próbce"}],"search_zh":"工作环境 － 空气 * 范围 范围 PN-Z-04481:2017-10","test_object_zh":"工作环境 － 空气 *"},{"_id":"6a82cee5884ede9a1b2c2eba","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - powietrze *","methodology":"Stężenie/zawartość metanolu","parameters":[{"name":"Zakres","range":"(10 – 200) mg/m3"},{"name":"Zakres","range":"(0,05 – 1,00) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość metanolu\nZakres:\nZakres (10 – 200) mg/m3\nZakres (0,05 – 1,00) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04476:2016-10","norm_bases":["PN-Z-04476:2016-10"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze * Stężenie/zawartość metanolu\nZakres:\nZakres (10 – 200) mg/m3\nZakres (0,05 – 1,00) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04476:2016-10 Srodowisko pracy - powietrze * Stezenie/zawartosc metanolu\nZakres:\nZakres (10 – 200) mg/m3\nZakres (0,05 – 1,00) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04476:2016-10","categories":["environment"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Methanol concentration/content","parameters_en":[{"name":"Range","range":"(10 – 200) mg/m3"},{"name":"Range","range":"(0,05 – 1,00) mg w próbce"}],"search_en":"Workplace environment - air * Methanol concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range PN-Z-04476:2016-10","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment - air *","parameters_zh":[{"name":"范围","range":"(10 – 200) mg/m3"},{"name":"范围","range":"(0,05 – 1,00) mg w próbce"}],"search_zh":"工作环境 － 空气 * 甲醇的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 PN-Z-04476:2016-10","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作环境 － 空气 *","methodology_zh":"甲醇的浓度/含量"},{"_id":"6a82cee5884ede9a1b2c2ebb","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - powietrze *","methodology":"Stężenie/zawartość kwasu octowego","parameters":[{"name":"Zakres","range":"(1,0 – 50) mg/m3"},{"name":"Zakres","range":"(0,025 – 1,25) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC –FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC –FID)"],"computed":[],"activity":"Stężenie/zawartość kwasu octowego\nZakres:\nZakres (1,0 – 50) mg/m3\nZakres (0,025 – 1,25) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC –FID)","reference":"PN-Z-04323:2004","norm_bases":["PN-Z-04323:2004"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze * Stężenie/zawartość kwasu octowego\nZakres:\nZakres (1,0 – 50) mg/m3\nZakres (0,025 – 1,25) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC –FID) PN-Z-04323:2004 Srodowisko pracy - powietrze * Stezenie/zawartosc kwasu octowego\nZakres:\nZakres (1,0 – 50) mg/m3\nZakres (0,025 – 1,25) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC –FID) PN-Z-04323:2004","categories":["environment"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Acetic acid concentration/content","parameters_en":[{"name":"Range","range":"(1,0 – 50) mg/m3"},{"name":"Range","range":"(0,025 – 1,25) mg w próbce"}],"search_en":"Workplace environment - air * Acetic acid concentration/content Range Range PN-Z-04323:2004","test_object_en":"Workplace environment - air *","parameters_zh":[{"name":"范围","range":"(1,0 – 50) mg/m3"},{"name":"范围","range":"(0,025 – 1,25) mg w próbce"}],"search_zh":"工作环境 － 空气 * 乙酸的浓度/含量 范围 范围 PN-Z-04323:2004","test_object_zh":"工作环境 － 空气 *","methodology_zh":"乙酸的浓度/含量"},{"_id":"6a82cee5884ede9a1b2c2ebc","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - powietrze *","methodology":"Stężenie/zawartość octanu metylu","parameters":[{"name":"octan metylu","range":"(20 – 500) mg/m3"},{"name":"Zakres","range":"(0,20 – 5,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)"],"computed":[],"activity":"Stężenie/zawartość octanu metylu\nZakres:\noctan metylu (20 – 500) mg/m3\nZakres (0,20 – 5,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)","reference":"NIOSH Method 1458 Issue 2 (1994) EHS-PB-10 wyd. 5 z 29.05.2019","norm_bases":["NIOSH Method 1458 Issue 2 (1994) EHS-PB-10 wyd. 5 z 29.05.2019"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze * Stężenie/zawartość octanu metylu\nZakres:\noctan metylu (20 – 500) mg/m3\nZakres (0,20 – 5,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID) NIOSH Method 1458 Issue 2 (1994) EHS-PB-10 wyd. 5 z 29.05.2019 Srodowisko pracy - powietrze * Stezenie/zawartosc octanu metylu\nZakres:\noctan metylu (20 – 500) mg/m3\nZakres (0,20 – 5,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC – FID) NIOSH Method 1458 Issue 2 (1994) EHS-PB-10 wyd. 5 z 29.05.2019","categories":["environment"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Methyl acetate concentration/content","parameters_en":[{"name":"methyl acetate","range":"(20 – 500) mg/m3"},{"name":"Range","range":"(0,20 – 5,0) mg w próbce"}],"search_en":"Workplace environment - air * Methyl acetate concentration/content Gas chromatography with flame ionization detection (GC – FID) methyl acetate Range NIOSH Method 1458 Issue 2 (1994) EHS-PB-10 wyd. 5 z 29.05.2019","technique_en":"Gas chromatography with flame ionization detection (GC – FID)","test_object_en":"Workplace environment - air *","parameters_zh":[{"name":"乙酸甲酯","range":"(20 – 500) mg/m3"},{"name":"范围","range":"(0,20 – 5,0) mg w próbce"}],"search_zh":"工作环境 － 空气 * 乙酸甲酯的浓度/含量 乙酸甲酯 范围 NIOSH Method 1458 Issue 2 (1994) EHS-PB-10 wyd. 5 z 29.05.2019","test_object_zh":"工作环境 － 空气 *","methodology_zh":"乙酸甲酯的浓度/含量"},{"_id":"6a82cee5884ede9a1b2c2ebd","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - powietrze *","methodology":"Stężenie/zawartość octanu etylu","parameters":[{"name":"Zakres","range":"(60 – 1500) mg/m3"},{"name":"Zakres","range":"(0,60 – 15) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość octanu etylu\nZakres:\nZakres (60 – 1500) mg/m3\nZakres (0,60 – 15) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"NIOSH Method 1457 Issue 1 (1994) EHS-PB-10 wyd. 5 z 29.05.2019","norm_bases":["NIOSH Method 1457 Issue 1 (1994) EHS-PB-10 wyd. 5 z 29.05.2019"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze * Stężenie/zawartość octanu etylu\nZakres:\nZakres (60 – 1500) mg/m3\nZakres (0,60 – 15) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) NIOSH Method 1457 Issue 1 (1994) EHS-PB-10 wyd. 5 z 29.05.2019 Srodowisko pracy - powietrze * Stezenie/zawartosc octanu etylu\nZakres:\nZakres (60 – 1500) mg/m3\nZakres (0,60 – 15) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) NIOSH Method 1457 Issue 1 (1994) EHS-PB-10 wyd. 5 z 29.05.2019","categories":["environment"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ethyl acetate concentration/content","parameters_en":[{"name":"Range","range":"(60 – 1500) mg/m3"},{"name":"Range","range":"(0,60 – 15) mg w próbce"}],"search_en":"Workplace environment - air * Ethyl acetate concentration/content Gas chromatography with flame ionization detection (GC-FID) Range Range NIOSH Method 1457 Issue 1 (1994) EHS-PB-10 wyd. 5 z 29.05.2019","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment - air *","parameters_zh":[{"name":"范围","range":"(60 – 1500) mg/m3"},{"name":"范围","range":"(0,60 – 15) mg w próbce"}],"search_zh":"工作环境 － 空气 * 乙酸乙酯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 范围 NIOSH Method 1457 Issue 1 (1994) EHS-PB-10 wyd. 5 z 29.05.2019","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作环境 － 空气 *","methodology_zh":"乙酸乙酯的浓度/含量"},{"_id":"6a82cee5884ede9a1b2c2ebe","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - powietrze *","methodology":"Stężenie/zawartość octanu n-propylu, octanu n-butylu, octanu n-amylu","parameters":[{"name":"octan n-propylu","range":"(20 - 500) mg/m3"},{"name":"Zakres","range":"(0,20 – 5,0) mg w próbce"},{"name":"octan n-butylu","range":"(20 - 500) mg/m3"},{"name":"(0,20 – 5,0) mg w próbce"},{"name":"octan pentylu","range":"(20 – 500) mg/m3"},{"name":"(0,20 – 5,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)"],"computed":[],"activity":"Stężenie/zawartość octanu n-propylu, octanu n-butylu, octanu n-amylu\nZakres:\noctan n-propylu (20 - 500) mg/m3\nZakres (0,20 – 5,0) mg w próbce\noctan n-butylu (20 - 500) mg/m3\n(0,20 – 5,0) mg w próbce\noctan pentylu (20 – 500) mg/m3\n(0,20 – 5,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)","reference":"NIOSH Method 1450 Issue 3 (2003) EHS-PB-10 wyd. 5 z 29.05.2019","norm_bases":["NIOSH Method 1450 Issue 3 (2003) EHS-PB-10 wyd. 5 z 29.05.2019"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze * Stężenie/zawartość octanu n-propylu, octanu n-butylu, octanu n-amylu\nZakres:\noctan n-propylu (20 - 500) mg/m3\nZakres (0,20 – 5,0) mg w próbce\noctan n-butylu (20 - 500) mg/m3\n(0,20 – 5,0) mg w próbce\noctan pentylu (20 – 500) mg/m3\n(0,20 – 5,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID) NIOSH Method 1450 Issue 3 (2003) EHS-PB-10 wyd. 5 z 29.05.2019 Srodowisko pracy - powietrze * Stezenie/zawartosc octanu n-propylu, octanu n-butylu, octanu n-amylu\nZakres:\noctan n-propylu (20 - 500) mg/m3\nZakres (0,20 – 5,0) mg w probce\noctan n-butylu (20 - 500) mg/m3\n(0,20 – 5,0) mg w probce\noctan pentylu (20 – 500) mg/m3\n(0,20 – 5,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC – FID) NIOSH Method 1450 Issue 3 (2003) EHS-PB-10 wyd. 5 z 29.05.2019","categories":["environment"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"octan n-propylu","range":"(20 - 500) mg/m3"},{"name":"Range","range":"(0,20 – 5,0) mg w próbce"},{"name":"n-butyl acetate","range":"(20 - 500) mg/m3"},{"name":"(0,20 – 5,0) mg w próbce"},{"name":"pentyl acetate","range":"(20 – 500) mg/m3"},{"name":"(0,20 – 5,0) mg w próbce"}],"search_en":"Workplace environment - air * Gas chromatography with flame ionization detection (GC – FID) Range n-butyl acetate pentyl acetate NIOSH Method 1450 Issue 3 (2003) EHS-PB-10 wyd. 5 z 29.05.2019","technique_en":"Gas chromatography with flame ionization detection (GC – FID)","test_object_en":"Workplace environment - air *","parameters_zh":[{"name":"octan n-propylu","range":"(20 - 500) mg/m3"},{"name":"范围","range":"(0,20 – 5,0) mg w próbce"},{"name":"乙酸正丁酯","range":"(20 - 500) mg/m3"},{"name":"(0,20 – 5,0) mg w próbce"},{"name":"octan pentylu","range":"(20 – 500) mg/m3"},{"name":"(0,20 – 5,0) mg w próbce"}],"search_zh":"工作环境 － 空气 * 范围 乙酸正丁酯 NIOSH Method 1450 Issue 3 (2003) EHS-PB-10 wyd. 5 z 29.05.2019","test_object_zh":"工作环境 － 空气 *"},{"_id":"6a82cee5884ede9a1b2c2ebf","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - powietrze *","methodology":"Stężenie/zawartość benzyny ekstrakcyjnej","parameters":[{"name":"Zakres","range":"(12,5 – 1500) mg/m3"},{"name":"Zakres","range":"(0,125 – 6,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)"],"computed":[],"activity":"Stężenie/zawartość benzyny ekstrakcyjnej\nZakres:\nZakres (12,5 – 1500) mg/m3\nZakres (0,125 – 6,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)","reference":"PN-Z-04134-02:1981","norm_bases":["PN-Z-04134-02:1981"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze * Stężenie/zawartość benzyny ekstrakcyjnej\nZakres:\nZakres (12,5 – 1500) mg/m3\nZakres (0,125 – 6,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID) PN-Z-04134-02:1981 Srodowisko pracy - powietrze * Stezenie/zawartosc benzyny ekstrakcyjnej\nZakres:\nZakres (12,5 – 1500) mg/m3\nZakres (0,125 – 6,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC – FID) PN-Z-04134-02:1981","categories":["environment"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Extraction naphtha concentration/content","parameters_en":[{"name":"Range","range":"(12,5 – 1500) mg/m3"},{"name":"Range","range":"(0,125 – 6,0) mg w próbce"}],"search_en":"Workplace environment - air * Extraction naphtha concentration/content Gas chromatography with flame ionization detection (GC – FID) Range Range PN-Z-04134-02:1981","technique_en":"Gas chromatography with flame ionization detection (GC – FID)","test_object_en":"Workplace environment - air *","parameters_zh":[{"name":"范围","range":"(12,5 – 1500) mg/m3"},{"name":"范围","range":"(0,125 – 6,0) mg w próbce"}],"search_zh":"工作环境 － 空气 * 抽提汽油的浓度/含量 范围 范围 PN-Z-04134-02:1981","test_object_zh":"工作环境 － 空气 *","methodology_zh":"抽提汽油的浓度/含量"},{"_id":"6a82cee5884ede9a1b2c2ec0","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - powietrze *","methodology":"Stężenie/zawartość benzenu, toluenu, etylobenzenu, o-ksylenu, m-ksylenu, p-ksylenu","parameters":[{"name":"benzen","range":"(0,10 – 4,0) mg/m3"},{"name":"Zakres","range":"(0,003 – 0,12) mg w próbce"},{"name":"toluen","range":"(5,0 – 200) mg/m3"},{"name":"(0,04 – 1,6) mg w próbce"},{"name":"etylobenzen","range":"(10 – 400) mg/m3"},{"name":"(0,24 – 9,6) mg w próbce"},{"name":"o-ksylen","range":"(7,5 – 300) mg/m3"},{"name":"(0,18 – 7,2) mg w próbce"},{"name":"m-ksylen","range":"(7,5 – 300) mg/m3"},{"name":"(0,18 – 7,2) mg w próbce"},{"name":"p-ksylen","range":"(7,5 – 300) mg/m3"},{"name":"(0,18 – 7,2) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)"],"computed":[],"activity":"Stężenie/zawartość benzenu, toluenu, etylobenzenu, o-ksylenu, m-ksylenu, p-ksylenu\nZakres:\nbenzen (0,10 – 4,0) mg/m3\nZakres (0,003 – 0,12) mg w próbce\ntoluen (5,0 – 200) mg/m3\n(0,04 – 1,6) mg w próbce\netylobenzen (10 – 400) mg/m3\n(0,24 – 9,6) mg w próbce\no-ksylen (7,5 – 300) mg/m3\n(0,18 – 7,2) mg w próbce\nm-ksylen (7,5 – 300) mg/m3\n(0,18 – 7,2) mg w próbce\np-ksylen (7,5 – 300) mg/m3\n(0,18 – 7,2) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)","reference":"NIOSH Method 1501 Issue 3 (2003)","norm_bases":["NIOSH Method 1501 Issue 3 (2003)"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze * Stężenie/zawartość benzenu, toluenu, etylobenzenu, o-ksylenu, m-ksylenu, p-ksylenu\nZakres:\nbenzen (0,10 – 4,0) mg/m3\nZakres (0,003 – 0,12) mg w próbce\ntoluen (5,0 – 200) mg/m3\n(0,04 – 1,6) mg w próbce\netylobenzen (10 – 400) mg/m3\n(0,24 – 9,6) mg w próbce\no-ksylen (7,5 – 300) mg/m3\n(0,18 – 7,2) mg w próbce\nm-ksylen (7,5 – 300) mg/m3\n(0,18 – 7,2) mg w próbce\np-ksylen (7,5 – 300) mg/m3\n(0,18 – 7,2) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID) NIOSH Method 1501 Issue 3 (2003) Srodowisko pracy - powietrze * Stezenie/zawartosc benzenu, toluenu, etylobenzenu, o-ksylenu, m-ksylenu, p-ksylenu\nZakres:\nbenzen (0,10 – 4,0) mg/m3\nZakres (0,003 – 0,12) mg w probce\ntoluen (5,0 – 200) mg/m3\n(0,04 – 1,6) mg w probce\netylobenzen (10 – 400) mg/m3\n(0,24 – 9,6) mg w probce\no-ksylen (7,5 – 300) mg/m3\n(0,18 – 7,2) mg w probce\nm-ksylen (7,5 – 300) mg/m3\n(0,18 – 7,2) mg w probce\np-ksylen (7,5 – 300) mg/m3\n(0,18 – 7,2) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC – FID) NIOSH Method 1501 Issue 3 (2003)","categories":["environment"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"benzene","range":"(0,10 – 4,0) mg/m3"},{"name":"Range","range":"(0,003 – 0,12) mg w próbce"},{"name":"toluene","range":"(5,0 – 200) mg/m3"},{"name":"(0,04 – 1,6) mg w próbce"},{"name":"ethylbenzene","range":"(10 – 400) mg/m3"},{"name":"(0,24 – 9,6) mg w próbce"},{"name":"o-xylene","range":"(7,5 – 300) mg/m3"},{"name":"(0,18 – 7,2) mg w próbce"},{"name":"m-xylene","range":"(7,5 – 300) mg/m3"},{"name":"(0,18 – 7,2) mg w próbce"},{"name":"p-xylene","range":"(7,5 – 300) mg/m3"},{"name":"(0,18 – 7,2) mg w próbce"}],"search_en":"Workplace environment - air * Gas chromatography with flame ionization detection (GC – FID) benzene Range toluene ethylbenzene o-xylene m-xylene p-xylene NIOSH Method 1501 Issue 3 (2003)","technique_en":"Gas chromatography with flame ionization detection (GC – FID)","test_object_en":"Workplace environment - air *","parameters_zh":[{"name":"苯","range":"(0,10 – 4,0) mg/m3"},{"name":"范围","range":"(0,003 – 0,12) mg w próbce"},{"name":"甲苯","range":"(5,0 – 200) mg/m3"},{"name":"(0,04 – 1,6) mg w próbce"},{"name":"乙苯","range":"(10 – 400) mg/m3"},{"name":"(0,24 – 9,6) mg w próbce"},{"name":"邻二甲苯","range":"(7,5 – 300) mg/m3"},{"name":"(0,18 – 7,2) mg w próbce"},{"name":"间二甲苯","range":"(7,5 – 300) mg/m3"},{"name":"(0,18 – 7,2) mg w próbce"},{"name":"p-ksylen","range":"(7,5 – 300) mg/m3"},{"name":"(0,18 – 7,2) mg w próbce"}],"search_zh":"工作环境 － 空气 * 苯 范围 甲苯 乙苯 邻二甲苯 间二甲苯 NIOSH Method 1501 Issue 3 (2003)","test_object_zh":"工作环境 － 空气 *"},{"_id":"6a82cee5884ede9a1b2c2ec1","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - powietrze *","methodology":"Stężenie/zawartość acetonu, 4-metylopentan-2-onu","parameters":[{"name":"aceton","range":"(60 – 2400) mg/m3"},{"name":"Zakres","range":"(0,18 – 7,2) mg w próbce"},{"name":"4-metylopentan-2-onu","range":"(6,0 – 240) mg/m3"},{"name":"(0,06 – 2,4) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)"],"computed":[],"activity":"Stężenie/zawartość acetonu, 4-metylopentan-2-onu\nZakres:\naceton (60 – 2400) mg/m3\nZakres (0,18 – 7,2) mg w próbce\n4-metylopentan-2-onu (6,0 – 240) mg/m3\n(0,06 – 2,4) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)","reference":"NIOSH Method 1300 Issue 2 (1994)","norm_bases":["NIOSH Method 1300 Issue 2 (1994)"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze * Stężenie/zawartość acetonu, 4-metylopentan-2-onu\nZakres:\naceton (60 – 2400) mg/m3\nZakres (0,18 – 7,2) mg w próbce\n4-metylopentan-2-onu (6,0 – 240) mg/m3\n(0,06 – 2,4) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID) NIOSH Method 1300 Issue 2 (1994) Srodowisko pracy - powietrze * Stezenie/zawartosc acetonu, 4-metylopentan-2-onu\nZakres:\naceton (60 – 2400) mg/m3\nZakres (0,18 – 7,2) mg w probce\n4-metylopentan-2-onu (6,0 – 240) mg/m3\n(0,06 – 2,4) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC – FID) NIOSH Method 1300 Issue 2 (1994)","categories":["environment"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"acetone","range":"(60 – 2400) mg/m3"},{"name":"Range","range":"(0,18 – 7,2) mg w próbce"},{"name":"4-methylpentan-2-one","range":"(6,0 – 240) mg/m3"},{"name":"(0,06 – 2,4) mg w próbce"}],"search_en":"Workplace environment - air * Gas chromatography with flame ionization detection (GC – FID) acetone Range 4-methylpentan-2-one NIOSH Method 1300 Issue 2 (1994)","technique_en":"Gas chromatography with flame ionization detection (GC – FID)","test_object_en":"Workplace environment - air *","parameters_zh":[{"name":"丙酮","range":"(60 – 2400) mg/m3"},{"name":"范围","range":"(0,18 – 7,2) mg w próbce"},{"name":"4-甲基-2-戊酮","range":"(6,0 – 240) mg/m3"},{"name":"(0,06 – 2,4) mg w próbce"}],"search_zh":"工作环境 － 空气 * 丙酮 范围 4-甲基-2-戊酮 NIOSH Method 1300 Issue 2 (1994)","test_object_zh":"工作环境 － 空气 *"},{"_id":"6a82cee5884ede9a1b2c2ec2","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - powietrze *","methodology":"Stężenie/zawartość dichlorometanu","parameters":[{"name":"dichlorometan","range":"(8,8 – 176) mg/m3"},{"name":"Zakres","range":"(0,0528 – 1,056) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)"],"computed":[],"activity":"Stężenie/zawartość dichlorometanu\nZakres:\ndichlorometan (8,8 – 176) mg/m3\nZakres (0,0528 – 1,056) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)","reference":"PN-Z-04437:2011","norm_bases":["PN-Z-04437:2011"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze * Stężenie/zawartość dichlorometanu\nZakres:\ndichlorometan (8,8 – 176) mg/m3\nZakres (0,0528 – 1,056) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID) PN-Z-04437:2011 Srodowisko pracy - powietrze * Stezenie/zawartosc dichlorometanu\nZakres:\ndichlorometan (8,8 – 176) mg/m3\nZakres (0,0528 – 1,056) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC – FID) PN-Z-04437:2011","categories":["environment"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dichloromethane concentration/content","parameters_en":[{"name":"dichloromethane","range":"(8,8 – 176) mg/m3"},{"name":"Range","range":"(0,0528 – 1,056) mg w próbce"}],"search_en":"Workplace environment - air * Dichloromethane concentration/content Gas chromatography with flame ionization detection (GC – FID) dichloromethane Range PN-Z-04437:2011","technique_en":"Gas chromatography with flame ionization detection (GC – FID)","test_object_en":"Workplace environment - air *","parameters_zh":[{"name":"二氯甲烷","range":"(8,8 – 176) mg/m3"},{"name":"范围","range":"(0,0528 – 1,056) mg w próbce"}],"search_zh":"工作环境 － 空气 * 二氯甲烷的浓度/含量 二氯甲烷 范围 PN-Z-04437:2011","test_object_zh":"工作环境 － 空气 *","methodology_zh":"二氯甲烷的浓度/含量"},{"_id":"6a82cee5884ede9a1b2c2ec3","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - powietrze *","methodology":"Stężenie/zawartość chloroformu","parameters":[{"name":"Zakres","range":"(0,40 – 16) mg/m3"},{"name":"Zakres","range":"(0,02 – 0,80) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)"],"computed":[],"activity":"Stężenie/zawartość chloroformu\nZakres:\nZakres (0,40 – 16) mg/m3\nZakres (0,02 – 0,80) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)","reference":"NIOSH Method 1003 Issue 3 (2003)","norm_bases":["NIOSH Method 1003 Issue 3 (2003)"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze * Stężenie/zawartość chloroformu\nZakres:\nZakres (0,40 – 16) mg/m3\nZakres (0,02 – 0,80) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID) NIOSH Method 1003 Issue 3 (2003) Srodowisko pracy - powietrze * Stezenie/zawartosc chloroformu\nZakres:\nZakres (0,40 – 16) mg/m3\nZakres (0,02 – 0,80) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC – FID) NIOSH Method 1003 Issue 3 (2003)","categories":["environment"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of chloroform","parameters_en":[{"name":"Range","range":"(0,40 – 16) mg/m3"},{"name":"Range","range":"(0,02 – 0,80) mg w próbce"}],"search_en":"Workplace environment - air * Concentration/content of chloroform Gas chromatography with flame ionization detection (GC – FID) Range Range NIOSH Method 1003 Issue 3 (2003)","technique_en":"Gas chromatography with flame ionization detection (GC – FID)","test_object_en":"Workplace environment - air *","parameters_zh":[{"name":"范围","range":"(0,40 – 16) mg/m3"},{"name":"范围","range":"(0,02 – 0,80) mg w próbce"}],"search_zh":"工作环境 － 空气 * 范围 范围 NIOSH Method 1003 Issue 3 (2003)","test_object_zh":"工作环境 － 空气 *"},{"_id":"6a82cee5884ede9a1b2c2ec4","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - powietrze *","methodology":"Stężenie/zawartość 1-butanolu","parameters":[{"name":"Zakres","range":"(5,0 – 300) mg/m3"},{"name":"Zakres","range":"(0,05 – 3,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)"],"computed":[],"activity":"Stężenie/zawartość 1-butanolu\nZakres:\nZakres (5,0 – 300) mg/m3\nZakres (0,05 – 3,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)","reference":"NIOSH Method 1405 Issue 1 (2003)","norm_bases":["NIOSH Method 1405 Issue 1 (2003)"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze * Stężenie/zawartość 1-butanolu\nZakres:\nZakres (5,0 – 300) mg/m3\nZakres (0,05 – 3,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID) NIOSH Method 1405 Issue 1 (2003) Srodowisko pracy - powietrze * Stezenie/zawartosc 1-butanolu\nZakres:\nZakres (5,0 – 300) mg/m3\nZakres (0,05 – 3,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC – FID) NIOSH Method 1405 Issue 1 (2003)","categories":["environment"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(5,0 – 300) mg/m3"},{"name":"Range","range":"(0,05 – 3,0) mg w próbce"}],"search_en":"Workplace environment - air * Gas chromatography with flame ionization detection (GC – FID) Range Range NIOSH Method 1405 Issue 1 (2003)","technique_en":"Gas chromatography with flame ionization detection (GC – FID)","test_object_en":"Workplace environment - air *","parameters_zh":[{"name":"范围","range":"(5,0 – 300) mg/m3"},{"name":"范围","range":"(0,05 – 3,0) mg w próbce"}],"search_zh":"工作环境 － 空气 * 范围 范围 NIOSH Method 1405 Issue 1 (2003)","test_object_zh":"工作环境 － 空气 *"},{"_id":"6a82cee5884ede9a1b2c2ec5","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - powietrze *","methodology":"Stężenie/zawartość benzyny do lakierów","parameters":[{"name":"Zakres","range":"(2,78 – 614,7) mg/m3"},{"name":"Zakres","range":"(0,10 – 22,13) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)"],"computed":[],"activity":"Stężenie/zawartość benzyny do lakierów\nZakres:\nZakres (2,78 – 614,7) mg/m3\nZakres (0,10 – 22,13) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)","reference":"PN-81/Z-04134.03","norm_bases":["PN-81/Z-04134.03"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze * Stężenie/zawartość benzyny do lakierów\nZakres:\nZakres (2,78 – 614,7) mg/m3\nZakres (0,10 – 22,13) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID) PN-81/Z-04134.03 Srodowisko pracy - powietrze * Stezenie/zawartosc benzyny do lakierow\nZakres:\nZakres (2,78 – 614,7) mg/m3\nZakres (0,10 – 22,13) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC – FID) PN-81/Z-04134.03","categories":["environment","automotive"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"White spirit concentration/content","parameters_en":[{"name":"Range","range":"(2,78 – 614,7) mg/m3"},{"name":"Range","range":"(0,10 – 22,13) mg w próbce"}],"search_en":"Workplace environment - air * White spirit concentration/content Gas chromatography with flame ionization detection (GC – FID) Range Range PN-81/Z-04134.03","technique_en":"Gas chromatography with flame ionization detection (GC – FID)","test_object_en":"Workplace environment - air *","parameters_zh":[{"name":"范围","range":"(2,78 – 614,7) mg/m3"},{"name":"范围","range":"(0,10 – 22,13) mg w próbce"}],"search_zh":"工作环境 － 空气 * 油漆用溶剂汽油的浓度/含量 范围 范围 PN-81/Z-04134.03","test_object_zh":"工作环境 － 空气 *","methodology_zh":"油漆用溶剂汽油的浓度/含量"},{"_id":"6a82cee5884ede9a1b2c2ec6","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - powietrze *","methodology":"Stężenie/zawartość terpentyny","parameters":[{"name":"Zakres","range":"(10 – 300) mg/m3"},{"name":"Zakres","range":"(0,10 – 3,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)"],"computed":[],"activity":"Stężenie/zawartość terpentyny\nZakres:\nZakres (10 – 300) mg/m3\nZakres (0,10 – 3,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)","reference":"NIOSH Method 1551 Issue 2 (1994)","norm_bases":["NIOSH Method 1551 Issue 2 (1994)"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze * Stężenie/zawartość terpentyny\nZakres:\nZakres (10 – 300) mg/m3\nZakres (0,10 – 3,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID) NIOSH Method 1551 Issue 2 (1994) Srodowisko pracy - powietrze * Stezenie/zawartosc terpentyny\nZakres:\nZakres (10 – 300) mg/m3\nZakres (0,10 – 3,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC – FID) NIOSH Method 1551 Issue 2 (1994)","categories":["environment"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Turpentine concentration/content","parameters_en":[{"name":"Range","range":"(10 – 300) mg/m3"},{"name":"Range","range":"(0,10 – 3,0) mg w próbce"}],"search_en":"Workplace environment - air * Turpentine concentration/content Gas chromatography with flame ionization detection (GC – FID) Range Range NIOSH Method 1551 Issue 2 (1994)","technique_en":"Gas chromatography with flame ionization detection (GC – FID)","test_object_en":"Workplace environment - air *","parameters_zh":[{"name":"范围","range":"(10 – 300) mg/m3"},{"name":"范围","range":"(0,10 – 3,0) mg w próbce"}],"search_zh":"工作环境 － 空气 * 范围 范围 NIOSH Method 1551 Issue 2 (1994)","test_object_zh":"工作环境 － 空气 *"},{"_id":"6a82cee5884ede9a1b2c2ec7","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - powietrze *","methodology":"Stężenie/zawartość 1,4-dioksanu","parameters":[{"name":"Zakres","range":"(1,4 – 115) mg/m3"},{"name":"Zakres","range":"(0,05 – 4,13) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)"],"computed":[],"activity":"Stężenie/zawartość 1,4-dioksanu\nZakres:\nZakres (1,4 – 115) mg/m3\nZakres (0,05 – 4,13) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2009, nr 1(59), s. 141–146","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2009, nr 1(59), s. 141–146"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze * Stężenie/zawartość 1,4-dioksanu\nZakres:\nZakres (1,4 – 115) mg/m3\nZakres (0,05 – 4,13) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID) Podstawy i Metody Oceny Środowiska Pracy 2009, nr 1(59), s. 141–146 Srodowisko pracy - powietrze * Stezenie/zawartosc 1,4-dioksanu\nZakres:\nZakres (1,4 – 115) mg/m3\nZakres (0,05 – 4,13) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC – FID) Podstawy i Metody Oceny Srodowiska Pracy 2009, nr 1(59), s. 141–146","categories":["environment"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of 1,4-dioxane","parameters_en":[{"name":"Range","range":"(1,4 – 115) mg/m3"},{"name":"Range","range":"(0,05 – 4,13) mg w próbce"}],"search_en":"Workplace environment - air * Concentration/content of 1,4-dioxane Gas chromatography with flame ionization detection (GC – FID) Range Range Podstawy i Metody Oceny Środowiska Pracy 2009, nr 1(59), s. 141–146","technique_en":"Gas chromatography with flame ionization detection (GC – FID)","test_object_en":"Workplace environment - air *","parameters_zh":[{"name":"范围","range":"(1,4 – 115) mg/m3"},{"name":"范围","range":"(0,05 – 4,13) mg w próbce"}],"search_zh":"工作环境 － 空气 * 范围 范围 Podstawy i Metody Oceny Środowiska Pracy 2009, nr 1(59), s. 141–146","test_object_zh":"工作环境 － 空气 *"},{"_id":"6a82cee5884ede9a1b2c2ec8","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - powietrze *","methodology":"Stężenie/zawartość nafty","parameters":[{"name":"Zakres","range":"(10,00 – 4800) mg/m3"},{"name":"Zakres","range":"(0,36 – 7,2) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)"],"computed":[],"activity":"Stężenie/zawartość nafty\nZakres:\nZakres (10,00 – 4800) mg/m3\nZakres (0,36 – 7,2) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)","reference":"PN-Z-04227-02:1992","norm_bases":["PN-Z-04227-02:1992"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze * Stężenie/zawartość nafty\nZakres:\nZakres (10,00 – 4800) mg/m3\nZakres (0,36 – 7,2) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID) PN-Z-04227-02:1992 Srodowisko pracy - powietrze * Stezenie/zawartosc nafty\nZakres:\nZakres (10,00 – 4800) mg/m3\nZakres (0,36 – 7,2) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC – FID) PN-Z-04227-02:1992","categories":["environment"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kerosene concentration/content","parameters_en":[{"name":"Range","range":"(10,00 – 4800) mg/m3"},{"name":"Range","range":"(0,36 – 7,2) mg w próbce"}],"search_en":"Workplace environment - air * Kerosene concentration/content Gas chromatography with flame ionization detection (GC – FID) Range Range PN-Z-04227-02:1992","technique_en":"Gas chromatography with flame ionization detection (GC – FID)","test_object_en":"Workplace environment - air *","parameters_zh":[{"name":"范围","range":"(10,00 – 4800) mg/m3"},{"name":"范围","range":"(0,36 – 7,2) mg w próbce"}],"search_zh":"工作环境 － 空气 * 煤油的浓度/含量 范围 范围 PN-Z-04227-02:1992","test_object_zh":"工作环境 － 空气 *","methodology_zh":"煤油的浓度/含量"},{"_id":"6a82cee5884ede9a1b2c2ec9","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - powietrze *","methodology":"Stężenie/zawartość trimetylobenzenów, styrenu, cykloheksanu, cykloheksanonu, butan-2-onu","parameters":[{"name":"1,2,3-trimetylobenzen"},{"name":"Zakres","range":"(9 – 4330) mg/m3"},{"name":"Zakres","range":"(0,32 – 6,5) mg w próbce"},{"name":"1,2,4-trimetylobenzen","range":"(10 – 4767) mg/m3"},{"name":"(0,36 – 7,2) mg w próbce"},{"name":"1,3,5-trimetylobenzen","range":"(10 – 4767) mg/m3"},{"name":"(0,36 – 7,2) mg w próbce Suma trimetylobenzenów (z obliczeń)"},{"name":"styren","range":"(5,3 – 2480) mg/m3"},{"name":"(0,19 – 3,7) mg w próbce"},{"name":"cykloheksan","range":"(30 – 14400) mg/m3"},{"name":"(1,1 – 21,6) mg w próbce"},{"name":"cykloheksanon","range":"(3,9 – 1920) mg/m3"},{"name":"(0,14 – 2,88) mg w próbce"},{"name":"butan-2-on","range":"(45 – 22000) mg/m3"},{"name":"(1,6 – 32,5) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)"],"computed":[],"activity":"Stężenie/zawartość trimetylobenzenów, styrenu, cykloheksanu, cykloheksanonu, butan-2-onu\nZakres:\n1,2,3-trimetylobenzen\nZakres (9 – 4330) mg/m3\nZakres (0,32 – 6,5) mg w próbce\n1,2,4-trimetylobenzen (10 – 4767) mg/m3\n(0,36 – 7,2) mg w próbce\n1,3,5-trimetylobenzen (10 – 4767) mg/m3\n(0,36 – 7,2) mg w próbce Suma trimetylobenzenów (z obliczeń)\nstyren (5,3 – 2480) mg/m3\n(0,19 – 3,7) mg w próbce\ncykloheksan (30 – 14400) mg/m3\n(1,1 – 21,6) mg w próbce\ncykloheksanon (3,9 – 1920) mg/m3\n(0,14 – 2,88) mg w próbce\nbutan-2-on (45 – 22000) mg/m3\n(1,6 – 32,5) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2007, nr 1 (51), s. 141 - 147","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2007, nr 1 (51), s. 141 - 147"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze * Stężenie/zawartość trimetylobenzenów, styrenu, cykloheksanu, cykloheksanonu, butan-2-onu\nZakres:\n1,2,3-trimetylobenzen\nZakres (9 – 4330) mg/m3\nZakres (0,32 – 6,5) mg w próbce\n1,2,4-trimetylobenzen (10 – 4767) mg/m3\n(0,36 – 7,2) mg w próbce\n1,3,5-trimetylobenzen (10 – 4767) mg/m3\n(0,36 – 7,2) mg w próbce Suma trimetylobenzenów (z obliczeń)\nstyren (5,3 – 2480) mg/m3\n(0,19 – 3,7) mg w próbce\ncykloheksan (30 – 14400) mg/m3\n(1,1 – 21,6) mg w próbce\ncykloheksanon (3,9 – 1920) mg/m3\n(0,14 – 2,88) mg w próbce\nbutan-2-on (45 – 22000) mg/m3\n(1,6 – 32,5) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID) Podstawy i Metody Oceny Środowiska Pracy 2007, nr 1 (51), s. 141 - 147 Srodowisko pracy - powietrze * Stezenie/zawartosc trimetylobenzenow, styrenu, cykloheksanu, cykloheksanonu, butan-2-onu\nZakres:\n1,2,3-trimetylobenzen\nZakres (9 – 4330) mg/m3\nZakres (0,32 – 6,5) mg w probce\n1,2,4-trimetylobenzen (10 – 4767) mg/m3\n(0,36 – 7,2) mg w probce\n1,3,5-trimetylobenzen (10 – 4767) mg/m3\n(0,36 – 7,2) mg w probce Suma trimetylobenzenow (z obliczen)\nstyren (5,3 – 2480) mg/m3\n(0,19 – 3,7) mg w probce\ncykloheksan (30 – 14400) mg/m3\n(1,1 – 21,6) mg w probce\ncykloheksanon (3,9 – 1920) mg/m3\n(0,14 – 2,88) mg w probce\nbutan-2-on (45 – 22000) mg/m3\n(1,6 – 32,5) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC – FID) Podstawy i Metody Oceny Srodowiska Pracy 2007, nr 1 (51), s. 141 - 147","categories":["environment"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"1,2,3-trimethylbenzene"},{"name":"Range","range":"(9 – 4330) mg/m3"},{"name":"Range","range":"(0,32 – 6,5) mg w próbce"},{"name":"1,2,4-trimethylbenzene","range":"(10 – 4767) mg/m3"},{"name":"(0,36 – 7,2) mg w próbce"},{"name":"1,3,5-trimethylbenzene","range":"(10 – 4767) mg/m3"},{"name":"(0,36 – 7,2) mg w próbce Suma trimetylobenzenów (z obliczeń)"},{"name":"styrene","range":"(5,3 – 2480) mg/m3"},{"name":"(0,19 – 3,7) mg w próbce"},{"name":"cyclohexane","range":"(30 – 14400) mg/m3"},{"name":"(1,1 – 21,6) mg w próbce"},{"name":"cyclohexanone","range":"(3,9 – 1920) mg/m3"},{"name":"(0,14 – 2,88) mg w próbce"},{"name":"butan-2-one","range":"(45 – 22000) mg/m3"},{"name":"(1,6 – 32,5) mg w próbce"}],"search_en":"Workplace environment - air * Gas chromatography with flame ionization detection (GC – FID) 1,2,3-trimethylbenzene Range Range 1,2,4-trimethylbenzene 1,3,5-trimethylbenzene styrene cyclohexane cyclohexanone butan-2-one Podstawy i Metody Oceny Środowiska Pracy 2007, nr 1 (51), s. 141 - 147","technique_en":"Gas chromatography with flame ionization detection (GC – FID)","test_object_en":"Workplace environment - air *","parameters_zh":[{"name":"1,2,3-三甲苯"},{"name":"范围","range":"(9 – 4330) mg/m3"},{"name":"范围","range":"(0,32 – 6,5) mg w próbce"},{"name":"1,2,4-三甲苯","range":"(10 – 4767) mg/m3"},{"name":"(0,36 – 7,2) mg w próbce"},{"name":"1,3,5-三甲苯","range":"(10 – 4767) mg/m3"},{"name":"(0,36 – 7,2) mg w próbce Suma trimetylobenzenów (z obliczeń)"},{"name":"苯乙烯","range":"(5,3 – 2480) mg/m3"},{"name":"(0,19 – 3,7) mg w próbce"},{"name":"环己烷","range":"(30 – 14400) mg/m3"},{"name":"(1,1 – 21,6) mg w próbce"},{"name":"环己酮","range":"(3,9 – 1920) mg/m3"},{"name":"(0,14 – 2,88) mg w próbce"},{"name":"丁酮","range":"(45 – 22000) mg/m3"},{"name":"(1,6 – 32,5) mg w próbce"}],"search_zh":"工作环境 － 空气 * 1,2,3-三甲苯 范围 范围 1,2,4-三甲苯 1,3,5-三甲苯 苯乙烯 环己烷 环己酮 丁酮 Podstawy i Metody Oceny Środowiska Pracy 2007, nr 1 (51), s. 141 - 147","test_object_zh":"工作环境 － 空气 *"},{"_id":"6a82cee5884ede9a1b2c2eca","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - powietrze *","methodology":"Stężenie/zawartość adypinianu bis(2-etyloheksylu)","parameters":[{"name":"Zakres","range":"(40 – 800) mg/m3"},{"name":"Zakres","range":"(6 – 120) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)"],"computed":[],"activity":"Stężenie/zawartość adypinianu bis(2-etyloheksylu)\nZakres:\nZakres (40 – 800) mg/m3\nZakres (6 – 120) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)","reference":"PN-Z-04461:2015-10","norm_bases":["PN-Z-04461:2015-10"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze * Stężenie/zawartość adypinianu bis(2-etyloheksylu)\nZakres:\nZakres (40 – 800) mg/m3\nZakres (6 – 120) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID) PN-Z-04461:2015-10 Srodowisko pracy - powietrze * Stezenie/zawartosc adypinianu bis(2-etyloheksylu)\nZakres:\nZakres (40 – 800) mg/m3\nZakres (6 – 120) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC – FID) PN-Z-04461:2015-10","categories":["environment"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(40 – 800) mg/m3"},{"name":"Range","range":"(6 – 120) mg w próbce"}],"search_en":"Workplace environment - air * Gas chromatography with flame ionization detection (GC – FID) Range Range PN-Z-04461:2015-10","technique_en":"Gas chromatography with flame ionization detection (GC – FID)","test_object_en":"Workplace environment - air *","parameters_zh":[{"name":"范围","range":"(40 – 800) mg/m3"},{"name":"范围","range":"(6 – 120) mg w próbce"}],"search_zh":"工作环境 － 空气 * 范围 范围 PN-Z-04461:2015-10","test_object_zh":"工作环境 － 空气 *"},{"_id":"6a82cee5884ede9a1b2c2ecb","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - powietrze *","methodology":"Stężenie/zawartość N,N-dimetyloacetamidu","parameters":[{"name":"Zakres","range":"(2,0 – 160) mg/m3"},{"name":"Zakres","range":"(0,020 – 1,6) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)"],"computed":[],"activity":"Stężenie/zawartość N,N-dimetyloacetamidu\nZakres:\nZakres (2,0 – 160) mg/m3\nZakres (0,020 – 1,6) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)","reference":"PN-Z-04491:2017-10","norm_bases":["PN-Z-04491:2017-10"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze * Stężenie/zawartość N,N-dimetyloacetamidu\nZakres:\nZakres (2,0 – 160) mg/m3\nZakres (0,020 – 1,6) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID) PN-Z-04491:2017-10 Srodowisko pracy - powietrze * Stezenie/zawartosc N,N-dimetyloacetamidu\nZakres:\nZakres (2,0 – 160) mg/m3\nZakres (0,020 – 1,6) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC – FID) PN-Z-04491:2017-10","categories":["environment"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(2,0 – 160) mg/m3"},{"name":"Range","range":"(0,020 – 1,6) mg w próbce"}],"search_en":"Workplace environment - air * Gas chromatography with flame ionization detection (GC – FID) Range Range PN-Z-04491:2017-10","technique_en":"Gas chromatography with flame ionization detection (GC – FID)","test_object_en":"Workplace environment - air *","parameters_zh":[{"name":"范围","range":"(2,0 – 160) mg/m3"},{"name":"范围","range":"(0,020 – 1,6) mg w próbce"}],"search_zh":"工作环境 － 空气 * 范围 范围 PN-Z-04491:2017-10","test_object_zh":"工作环境 － 空气 *"},{"_id":"6a82cee5884ede9a1b2c2ecc","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - powietrze *","methodology":"Stężenie/zawartość glikolu etylenowego","parameters":[{"name":"Zakres","range":"(1,50 – 100) mg/m3"},{"name":"Zakres","range":"(0,030 – 2,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)"],"computed":[],"activity":"Stężenie/zawartość glikolu etylenowego\nZakres:\nZakres (1,50 – 100) mg/m3\nZakres (0,030 – 2,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)","reference":"Podstawy i Metody Oceny Środowiska Pracy 1997, nr 17, s. 55-59","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 1997, nr 17, s. 55-59"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze * Stężenie/zawartość glikolu etylenowego\nZakres:\nZakres (1,50 – 100) mg/m3\nZakres (0,030 – 2,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID) Podstawy i Metody Oceny Środowiska Pracy 1997, nr 17, s. 55-59 Srodowisko pracy - powietrze * Stezenie/zawartosc glikolu etylenowego\nZakres:\nZakres (1,50 – 100) mg/m3\nZakres (0,030 – 2,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC – FID) Podstawy i Metody Oceny Srodowiska Pracy 1997, nr 17, s. 55-59","categories":["environment"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ethylene glycol concentration/content","parameters_en":[{"name":"Range","range":"(1,50 – 100) mg/m3"},{"name":"Range","range":"(0,030 – 2,0) mg w próbce"}],"search_en":"Workplace environment - air * Ethylene glycol concentration/content Gas chromatography with flame ionization detection (GC – FID) Range Range Podstawy i Metody Oceny Środowiska Pracy 1997, nr 17, s. 55-59","technique_en":"Gas chromatography with flame ionization detection (GC – FID)","test_object_en":"Workplace environment - air *","parameters_zh":[{"name":"范围","range":"(1,50 – 100) mg/m3"},{"name":"范围","range":"(0,030 – 2,0) mg w próbce"}],"search_zh":"工作环境 － 空气 * 乙二醇的浓度/含量 范围 范围 Podstawy i Metody Oceny Środowiska Pracy 1997, nr 17, s. 55-59","test_object_zh":"工作环境 － 空气 *","methodology_zh":"乙二醇的浓度/含量"},{"_id":"6a82cee5884ede9a1b2c2ecd","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - powietrze *","methodology":"Stężenie/zawartość octanu 2-metoksy-1-metyloetylu","parameters":[{"name":"Zakres","range":"(26 – 1200) mg/m3"},{"name":"Zakres","range":"(0,26 – 12) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)"],"computed":[],"activity":"Stężenie/zawartość octanu 2-metoksy-1-metyloetylu\nZakres:\nZakres (26 – 1200) mg/m3\nZakres (0,26 – 12) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)","reference":"PN-Z-04119-10:2008","norm_bases":["PN-Z-04119-10:2008"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze * Stężenie/zawartość octanu 2-metoksy-1-metyloetylu\nZakres:\nZakres (26 – 1200) mg/m3\nZakres (0,26 – 12) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID) PN-Z-04119-10:2008 Srodowisko pracy - powietrze * Stezenie/zawartosc octanu 2-metoksy-1-metyloetylu\nZakres:\nZakres (26 – 1200) mg/m3\nZakres (0,26 – 12) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC – FID) PN-Z-04119-10:2008","categories":["environment"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"2-methoxy-1-methylethyl acetate concentration/content","parameters_en":[{"name":"Range","range":"(26 – 1200) mg/m3"},{"name":"Range","range":"(0,26 – 12) mg w próbce"}],"search_en":"Workplace environment - air * 2-methoxy-1-methylethyl acetate concentration/content Gas chromatography with flame ionization detection (GC – FID) Range Range PN-Z-04119-10:2008","technique_en":"Gas chromatography with flame ionization detection (GC – FID)","test_object_en":"Workplace environment - air *","parameters_zh":[{"name":"范围","range":"(26 – 1200) mg/m3"},{"name":"范围","range":"(0,26 – 12) mg w próbce"}],"search_zh":"工作环境 － 空气 * 丙二醇甲醚醋酸酯的浓度/含量 范围 范围 PN-Z-04119-10:2008","test_object_zh":"工作环境 － 空气 *","methodology_zh":"丙二醇甲醚醋酸酯的浓度/含量"},{"_id":"6a82cee5884ede9a1b2c2ece","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - powietrze *","methodology":"Stężenie/zawartość octanu 2-metoksypropylu","parameters":[{"name":"Zakres","range":"(10 – 400) mg/m3"},{"name":"Zakres","range":"(0,050 – 2,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)"],"computed":[],"activity":"Stężenie/zawartość octanu 2-metoksypropylu\nZakres:\nZakres (10 – 400) mg/m3\nZakres (0,050 – 2,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)","reference":"PN-Z-04305:2003","norm_bases":["PN-Z-04305:2003"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze * Stężenie/zawartość octanu 2-metoksypropylu\nZakres:\nZakres (10 – 400) mg/m3\nZakres (0,050 – 2,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID) PN-Z-04305:2003 Srodowisko pracy - powietrze * Stezenie/zawartosc octanu 2-metoksypropylu\nZakres:\nZakres (10 – 400) mg/m3\nZakres (0,050 – 2,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC – FID) PN-Z-04305:2003","categories":["environment"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(10 – 400) mg/m3"},{"name":"Range","range":"(0,050 – 2,0) mg w próbce"}],"search_en":"Workplace environment - air * Gas chromatography with flame ionization detection (GC – FID) Range Range PN-Z-04305:2003","technique_en":"Gas chromatography with flame ionization detection (GC – FID)","test_object_en":"Workplace environment - air *","parameters_zh":[{"name":"范围","range":"(10 – 400) mg/m3"},{"name":"范围","range":"(0,050 – 2,0) mg w próbce"}],"search_zh":"工作环境 － 空气 * 范围 范围 PN-Z-04305:2003","test_object_zh":"工作环境 － 空气 *"},{"_id":"6a82cee5884ede9a1b2c2ecf","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - powietrze *","methodology":"Stężenie/zawartość glicerolu – frakcja wdychalna","parameters":[{"name":"Zakres","range":"(1,01 – 20,20) mg/m3"},{"name":"Zakres","range":"(0,20 – 4,00) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)"],"computed":[],"activity":"Stężenie/zawartość glicerolu – frakcja wdychalna\nZakres:\nZakres (1,01 – 20,20) mg/m3\nZakres (0,20 – 4,00) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)","reference":"PN-Z-04374:2009","norm_bases":["PN-Z-04374:2009"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze * Stężenie/zawartość glicerolu – frakcja wdychalna\nZakres:\nZakres (1,01 – 20,20) mg/m3\nZakres (0,20 – 4,00) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID) PN-Z-04374:2009 Srodowisko pracy - powietrze * Stezenie/zawartosc glicerolu – frakcja wdychalna\nZakres:\nZakres (1,01 – 20,20) mg/m3\nZakres (0,20 – 4,00) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC – FID) PN-Z-04374:2009","categories":["environment"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(1,01 – 20,20) mg/m3"},{"name":"Range","range":"(0,20 – 4,00) mg w próbce"}],"search_en":"Workplace environment - air * Gas chromatography with flame ionization detection (GC – FID) Range Range PN-Z-04374:2009","technique_en":"Gas chromatography with flame ionization detection (GC – FID)","test_object_en":"Workplace environment - air *","parameters_zh":[{"name":"范围","range":"(1,01 – 20,20) mg/m3"},{"name":"范围","range":"(0,20 – 4,00) mg w próbce"}],"search_zh":"工作环境 － 空气 * 范围 范围 PN-Z-04374:2009","test_object_zh":"工作环境 － 空气 *"},{"_id":"6a82cee5884ede9a1b2c2ed0","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - powietrze *","methodology":"Stężenie/zawartość fenolu","parameters":[{"name":"Zakres","range":"(0,71 – 30,30) mg/m3"},{"name":"Zakres","range":"(0,014 – 0,600) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)"],"computed":[],"activity":"Stężenie/zawartość fenolu\nZakres:\nZakres (0,71 – 30,30) mg/m3\nZakres (0,014 – 0,600) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)","reference":"NIOSH Method 2546 Issue 1:1994","norm_bases":["NIOSH Method 2546 Issue 1:1994"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze * Stężenie/zawartość fenolu\nZakres:\nZakres (0,71 – 30,30) mg/m3\nZakres (0,014 – 0,600) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID) NIOSH Method 2546 Issue 1:1994 Srodowisko pracy - powietrze * Stezenie/zawartosc fenolu\nZakres:\nZakres (0,71 – 30,30) mg/m3\nZakres (0,014 – 0,600) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC – FID) NIOSH Method 2546 Issue 1:1994","categories":["environment"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phenol concentration/content","parameters_en":[{"name":"Range","range":"(0,71 – 30,30) mg/m3"},{"name":"Range","range":"(0,014 – 0,600) mg w próbce"}],"search_en":"Workplace environment - air * Phenol concentration/content Gas chromatography with flame ionization detection (GC – FID) Range Range NIOSH Method 2546 Issue 1:1994","technique_en":"Gas chromatography with flame ionization detection (GC – FID)","test_object_en":"Workplace environment - air *","parameters_zh":[{"name":"范围","range":"(0,71 – 30,30) mg/m3"},{"name":"范围","range":"(0,014 – 0,600) mg w próbce"}],"search_zh":"工作环境 － 空气 * 苯酚的浓度/含量 范围 范围 NIOSH Method 2546 Issue 1:1994","methodology_zh":"苯酚的浓度/含量","test_object_zh":"工作环境 － 空气 *"},{"_id":"6a82cee5884ede9a1b2c2ed1","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - powietrze *","methodology":"Stężenie/zawartość 1,2-dichloroetanu","parameters":[{"name":"Zakres","range":"(0,82 – 16,40) mg/m3"},{"name":"Zakres","range":"(0,010 – 0,197) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)"],"computed":[],"activity":"Stężenie/zawartość 1,2-dichloroetanu\nZakres:\nZakres (0,82 – 16,40) mg/m3\nZakres (0,010 – 0,197) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)","reference":"PN-Z-04501:2019-10","norm_bases":["PN-Z-04501:2019-10"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze * Stężenie/zawartość 1,2-dichloroetanu\nZakres:\nZakres (0,82 – 16,40) mg/m3\nZakres (0,010 – 0,197) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID) PN-Z-04501:2019-10 Srodowisko pracy - powietrze * Stezenie/zawartosc 1,2-dichloroetanu\nZakres:\nZakres (0,82 – 16,40) mg/m3\nZakres (0,010 – 0,197) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC – FID) PN-Z-04501:2019-10","categories":["environment"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of 1,2-dichloroethane","parameters_en":[{"name":"Range","range":"(0,82 – 16,40) mg/m3"},{"name":"Range","range":"(0,010 – 0,197) mg w próbce"}],"search_en":"Workplace environment - air * Concentration/content of 1,2-dichloroethane Gas chromatography with flame ionization detection (GC – FID) Range Range PN-Z-04501:2019-10","technique_en":"Gas chromatography with flame ionization detection (GC – FID)","test_object_en":"Workplace environment - air *","parameters_zh":[{"name":"范围","range":"(0,82 – 16,40) mg/m3"},{"name":"范围","range":"(0,010 – 0,197) mg w próbce"}],"search_zh":"工作环境 － 空气 * 范围 范围 PN-Z-04501:2019-10","test_object_zh":"工作环境 － 空气 *"},{"_id":"6a82cee5884ede9a1b2c2ed2","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - powietrze *","methodology":"Stężenie/zawartość 1,2-dichloroetenu – izomerów: cis -, trans -","parameters":[{"name":"cis 1,2-dichloroeten"},{"name":"Zakres","range":"(70,70 – 1414,14) mg/m3"},{"name":"Zakres","range":"(0,70 – 14,00) mg w próbce"},{"name":"trans 1,2-dichloroeten","range":"(70,70 – 1414,14) mg/m3"},{"name":"(0,70 – 14,00) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)"],"computed":[],"activity":"Stężenie/zawartość 1,2-dichloroetenu – izomerów: cis -, trans -\nZakres:\ncis 1,2-dichloroeten\nZakres (70,70 – 1414,14) mg/m3\nZakres (0,70 – 14,00) mg w próbce\ntrans 1,2-dichloroeten (70,70 – 1414,14) mg/m3\n(0,70 – 14,00) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID)","reference":"PN-Z-04270:2000","norm_bases":["PN-Z-04270:2000"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze * Stężenie/zawartość 1,2-dichloroetenu – izomerów: cis -, trans -\nZakres:\ncis 1,2-dichloroeten\nZakres (70,70 – 1414,14) mg/m3\nZakres (0,70 – 14,00) mg w próbce\ntrans 1,2-dichloroeten (70,70 – 1414,14) mg/m3\n(0,70 – 14,00) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC – FID) PN-Z-04270:2000 Srodowisko pracy - powietrze * Stezenie/zawartosc 1,2-dichloroetenu – izomerow: cis -, trans -\nZakres:\ncis 1,2-dichloroeten\nZakres (70,70 – 1414,14) mg/m3\nZakres (0,70 – 14,00) mg w probce\ntrans 1,2-dichloroeten (70,70 – 1414,14) mg/m3\n(0,70 – 14,00) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC – FID) PN-Z-04270:2000","categories":["environment"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"cis 1,2-dichloroethene"},{"name":"Range","range":"(70,70 – 1414,14) mg/m3"},{"name":"Range","range":"(0,70 – 14,00) mg w próbce"},{"name":"trans 1,2-dichloroethene","range":"(70,70 – 1414,14) mg/m3"},{"name":"(0,70 – 14,00) mg w próbce"}],"search_en":"Workplace environment - air * Gas chromatography with flame ionization detection (GC – FID) cis 1,2-dichloroethene Range Range trans 1,2-dichloroethene PN-Z-04270:2000","technique_en":"Gas chromatography with flame ionization detection (GC – FID)","test_object_en":"Workplace environment - air *","parameters_zh":[{"name":"cis 1,2-dichloroeten"},{"name":"范围","range":"(70,70 – 1414,14) mg/m3"},{"name":"范围","range":"(0,70 – 14,00) mg w próbce"},{"name":"trans 1,2-dichloroeten","range":"(70,70 – 1414,14) mg/m3"},{"name":"(0,70 – 14,00) mg w próbce"}],"search_zh":"工作环境 － 空气 * 范围 范围 PN-Z-04270:2000","test_object_zh":"工作环境 － 空气 *"},{"_id":"6a82cee5884ede9a1b2c2ed3","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - powietrze *","methodology":"Stężenie/zawartość kwasu akrylowego","parameters":[{"name":"Zakres","range":"(1,0 – 40) mg/m3"},{"name":"Zakres","range":"(0,02 – 0,8) mg w próbce"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej (HPLC - UV)","techniques":["Metoda wysokosprawnej chromatografii cieczowej (HPLC - UV)"],"computed":[],"activity":"Stężenie/zawartość kwasu akrylowego\nZakres:\nZakres (1,0 – 40) mg/m3\nZakres (0,02 – 0,8) mg w próbce\nMetoda wysokosprawnej chromatografii cieczowej (HPLC - UV)","reference":"PN-Z-04460:2014-09","norm_bases":["PN-Z-04460:2014-09"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze * Stężenie/zawartość kwasu akrylowego\nZakres:\nZakres (1,0 – 40) mg/m3\nZakres (0,02 – 0,8) mg w próbce\nMetoda wysokosprawnej chromatografii cieczowej (HPLC - UV) PN-Z-04460:2014-09 Srodowisko pracy - powietrze * Stezenie/zawartosc kwasu akrylowego\nZakres:\nZakres (1,0 – 40) mg/m3\nZakres (0,02 – 0,8) mg w probce\nMetoda wysokosprawnej chromatografii cieczowej (HPLC - UV) PN-Z-04460:2014-09","categories":["environment"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Acrylic acid concentration/content","parameters_en":[{"name":"Range","range":"(1,0 – 40) mg/m3"},{"name":"Range","range":"(0,02 – 0,8) mg w próbce"}],"search_en":"Workplace environment - air * Acrylic acid concentration/content Range Range PN-Z-04460:2014-09","test_object_en":"Workplace environment - air *","parameters_zh":[{"name":"范围","range":"(1,0 – 40) mg/m3"},{"name":"范围","range":"(0,02 – 0,8) mg w próbce"}],"search_zh":"工作环境 － 空气 * 范围 范围 PN-Z-04460:2014-09","test_object_zh":"工作环境 － 空气 *"},{"_id":"6a82cee5884ede9a1b2c2ed4","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - powietrze *","methodology":"Stężenie/zawartość hydrochinonu","parameters":[{"name":"Zakres","range":"(0,1 – 2) mg/m3"},{"name":"Zakres","range":"(0,0018 – 0,036) mg w próbce"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej (HPLC - UV)","techniques":["Metoda wysokosprawnej chromatografii cieczowej (HPLC - UV)"],"computed":[],"activity":"Stężenie/zawartość hydrochinonu\nZakres:\nZakres (0,1 – 2) mg/m3\nZakres (0,0018 – 0,036) mg w próbce\nMetoda wysokosprawnej chromatografii cieczowej (HPLC - UV)","reference":"PN-Z-04479:2016","norm_bases":["PN-Z-04479:2016"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze * Stężenie/zawartość hydrochinonu\nZakres:\nZakres (0,1 – 2) mg/m3\nZakres (0,0018 – 0,036) mg w próbce\nMetoda wysokosprawnej chromatografii cieczowej (HPLC - UV) PN-Z-04479:2016 Srodowisko pracy - powietrze * Stezenie/zawartosc hydrochinonu\nZakres:\nZakres (0,1 – 2) mg/m3\nZakres (0,0018 – 0,036) mg w probce\nMetoda wysokosprawnej chromatografii cieczowej (HPLC - UV) PN-Z-04479:2016","categories":["environment"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of hydroquinone","parameters_en":[{"name":"Range","range":"(0,1 – 2) mg/m3"},{"name":"Range","range":"(0,0018 – 0,036) mg w próbce"}],"search_en":"Workplace environment - air * Concentration/content of hydroquinone Range Range PN-Z-04479:2016","test_object_en":"Workplace environment - air *","parameters_zh":[{"name":"范围","range":"(0,1 – 2) mg/m3"},{"name":"范围","range":"(0,0018 – 0,036) mg w próbce"}],"search_zh":"工作环境 － 空气 * 范围 范围 PN-Z-04479:2016","test_object_zh":"工作环境 － 空气 *"},{"_id":"6a82cee5884ede9a1b2c2ed5","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - powietrze *","methodology":"Stężenie/zawartość nadtlenku dibenzoilowego","parameters":[{"name":"Zakres","range":"(0,505 – 20,0) mg/m3"},{"name":"Zakres","range":"(0,050 – 2,0) mg w próbce"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC UV/DAD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC UV/DAD)"],"computed":[],"activity":"Stężenie/zawartość nadtlenku dibenzoilowego\nZakres:\nZakres (0,505 – 20,0) mg/m3\nZakres (0,050 – 2,0) mg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC UV/DAD)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 17, s. 97-100","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 17, s. 97-100"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze * Stężenie/zawartość nadtlenku dibenzoilowego\nZakres:\nZakres (0,505 – 20,0) mg/m3\nZakres (0,050 – 2,0) mg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC UV/DAD) Podstawy i Metody Oceny Środowiska Pracy 2016, nr 17, s. 97-100 Srodowisko pracy - powietrze * Stezenie/zawartosc nadtlenku dibenzoilowego\nZakres:\nZakres (0,505 – 20,0) mg/m3\nZakres (0,050 – 2,0) mg w probce\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC UV/DAD) Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 17, s. 97-100","categories":["environment"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,505 – 20,0) mg/m3"},{"name":"Range","range":"(0,050 – 2,0) mg w próbce"}],"search_en":"Workplace environment - air * Range Range Podstawy i Metody Oceny Środowiska Pracy 2016, nr 17, s. 97-100","test_object_en":"Workplace environment - air *","parameters_zh":[{"name":"范围","range":"(0,505 – 20,0) mg/m3"},{"name":"范围","range":"(0,050 – 2,0) mg w próbce"}],"search_zh":"工作环境 － 空气 * 范围 范围 Podstawy i Metody Oceny Środowiska Pracy 2016, nr 17, s. 97-100","test_object_zh":"工作环境 － 空气 *"},{"_id":"6a82cee5884ede9a1b2c2ed6","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - powietrze *","methodology":"Stężenie/zawartość fenoloftaleiny","parameters":[{"name":"Zakres","range":"(0,33 – 16,7) mg/m3"},{"name":"Zakres","range":"(0,08 – 4,0) mg w próbce"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC UV/DAD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC UV/DAD)"],"computed":[],"activity":"Stężenie/zawartość fenoloftaleiny\nZakres:\nZakres (0,33 – 16,7) mg/m3\nZakres (0,08 – 4,0) mg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC UV/DAD)","reference":"PN-Z-04506:2019-10","norm_bases":["PN-Z-04506:2019-10"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze * Stężenie/zawartość fenoloftaleiny\nZakres:\nZakres (0,33 – 16,7) mg/m3\nZakres (0,08 – 4,0) mg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC UV/DAD) PN-Z-04506:2019-10 Srodowisko pracy - powietrze * Stezenie/zawartosc fenoloftaleiny\nZakres:\nZakres (0,33 – 16,7) mg/m3\nZakres (0,08 – 4,0) mg w probce\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC UV/DAD) PN-Z-04506:2019-10","categories":["environment"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of phenolphthalein","parameters_en":[{"name":"Range","range":"(0,33 – 16,7) mg/m3"},{"name":"Range","range":"(0,08 – 4,0) mg w próbce"}],"search_en":"Workplace environment - air * Concentration/content of phenolphthalein Range Range PN-Z-04506:2019-10","test_object_en":"Workplace environment - air *","parameters_zh":[{"name":"范围","range":"(0,33 – 16,7) mg/m3"},{"name":"范围","range":"(0,08 – 4,0) mg w próbce"}],"search_zh":"工作环境 － 空气 * 范围 范围 PN-Z-04506:2019-10","test_object_zh":"工作环境 － 空气 *"},{"_id":"6a82cee5884ede9a1b2c2ed7","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - powietrze *","methodology":"Stężenie/zawartość 2-cyjanoakrylanu etylu","parameters":[{"name":"Zakres","range":"(0,10 – 4,0) mg/m3"},{"name":"Zakres","range":"(0,0012 – 0,048) mg w próbce"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC UV/DAD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC UV/DAD)"],"computed":[],"activity":"Stężenie/zawartość 2-cyjanoakrylanu etylu\nZakres:\nZakres (0,10 – 4,0) mg/m3\nZakres (0,0012 – 0,048) mg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC UV/DAD)","reference":"PN-Z-04467:2016-10","norm_bases":["PN-Z-04467:2016-10"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze * Stężenie/zawartość 2-cyjanoakrylanu etylu\nZakres:\nZakres (0,10 – 4,0) mg/m3\nZakres (0,0012 – 0,048) mg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC UV/DAD) PN-Z-04467:2016-10 Srodowisko pracy - powietrze * Stezenie/zawartosc 2-cyjanoakrylanu etylu\nZakres:\nZakres (0,10 – 4,0) mg/m3\nZakres (0,0012 – 0,048) mg w probce\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC UV/DAD) PN-Z-04467:2016-10","categories":["environment"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of ethyl 2-cyanoacrylate","parameters_en":[{"name":"Range","range":"(0,10 – 4,0) mg/m3"},{"name":"Range","range":"(0,0012 – 0,048) mg w próbce"}],"search_en":"Workplace environment - air * Concentration/content of ethyl 2-cyanoacrylate Range Range PN-Z-04467:2016-10","test_object_en":"Workplace environment - air *","parameters_zh":[{"name":"范围","range":"(0,10 – 4,0) mg/m3"},{"name":"范围","range":"(0,0012 – 0,048) mg w próbce"}],"search_zh":"工作环境 － 空气 * 范围 范围 PN-Z-04467:2016-10","test_object_zh":"工作环境 － 空气 *"},{"_id":"6a82cee5884ede9a1b2c2ed8","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - powietrze *","methodology":"Stężenie/zawartość N-hydroksymocznika","parameters":[{"name":"Zakres","range":"(0,001 – 0,08) mg/m3"},{"name":"Zakres","range":"(0,48 – 38,4) μg w próbce"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC UV)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC UV)"],"computed":[],"activity":"Stężenie/zawartość N-hydroksymocznika\nZakres:\nZakres (0,001 – 0,08) mg/m3\nZakres (0,48 – 38,4) μg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC UV)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2010, nr 1 (63), s. 155-162","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2010, nr 1 (63), s. 155-162"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze * Stężenie/zawartość N-hydroksymocznika\nZakres:\nZakres (0,001 – 0,08) mg/m3\nZakres (0,48 – 38,4) μg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC UV) Podstawy i Metody Oceny Środowiska Pracy 2010, nr 1 (63), s. 155-162 Srodowisko pracy - powietrze * Stezenie/zawartosc N-hydroksymocznika\nZakres:\nZakres (0,001 – 0,08) mg/m3\nZakres (0,48 – 38,4) μg w probce\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC UV) Podstawy i Metody Oceny Srodowiska Pracy 2010, nr 1 (63), s. 155-162","categories":["environment"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,001 – 0,08) mg/m3"},{"name":"Range","range":"(0,48 – 38,4) μg w próbce"}],"search_en":"Workplace environment - air * Range Range Podstawy i Metody Oceny Środowiska Pracy 2010, nr 1 (63), s. 155-162","test_object_en":"Workplace environment - air *","parameters_zh":[{"name":"范围","range":"(0,001 – 0,08) mg/m3"},{"name":"范围","range":"(0,48 – 38,4) μg w próbce"}],"search_zh":"工作环境 － 空气 * 范围 范围 Podstawy i Metody Oceny Środowiska Pracy 2010, nr 1 (63), s. 155-162","test_object_zh":"工作环境 － 空气 *"},{"_id":"6a82cee5884ede9a1b2c2ed9","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - powietrze *","methodology":"Stężenie/zawartość fluorouracyl – frakcja wdychalna","parameters":[{"name":"Zakres","range":"(0,00015 – 0,00733) mg/m3"},{"name":"Zakres","range":"(0,000105 – 0,00528) mg w próbce"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC UV)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC UV)"],"computed":[],"activity":"Stężenie/zawartość fluorouracyl – frakcja wdychalna\nZakres:\nZakres (0,00015 – 0,00733) mg/m3\nZakres (0,000105 – 0,00528) mg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC UV)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2020, nr 2 (104), s. 63-77","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2020, nr 2 (104), s. 63-77"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze * Stężenie/zawartość fluorouracyl – frakcja wdychalna\nZakres:\nZakres (0,00015 – 0,00733) mg/m3\nZakres (0,000105 – 0,00528) mg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC UV) Podstawy i Metody Oceny Środowiska Pracy 2020, nr 2 (104), s. 63-77 Srodowisko pracy - powietrze * Stezenie/zawartosc fluorouracyl – frakcja wdychalna\nZakres:\nZakres (0,00015 – 0,00733) mg/m3\nZakres (0,000105 – 0,00528) mg w probce\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC UV) Podstawy i Metody Oceny Srodowiska Pracy 2020, nr 2 (104), s. 63-77","categories":["environment"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,00015 – 0,00733) mg/m3"},{"name":"Range","range":"(0,000105 – 0,00528) mg w próbce"}],"search_en":"Workplace environment - air * Range Range Podstawy i Metody Oceny Środowiska Pracy 2020, nr 2 (104), s. 63-77","test_object_en":"Workplace environment - air *","parameters_zh":[{"name":"范围","range":"(0,00015 – 0,00733) mg/m3"},{"name":"范围","range":"(0,000105 – 0,00528) mg w próbce"}],"search_zh":"工作环境 － 空气 * 范围 范围 Podstawy i Metody Oceny Środowiska Pracy 2020, nr 2 (104), s. 63-77","test_object_zh":"工作环境 － 空气 *"},{"_id":"6a82cee5884ede9a1b2c2eda","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - powietrze *","methodology":"Stężenie/zawartość akrylamidu","parameters":[{"name":"Zakres","range":"(0,0070 – 0,14) mg/m3"},{"name":"Zakres","range":"(0,00084 – 0,017) mg w próbce"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC UV)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC UV)"],"computed":[],"activity":"Stężenie/zawartość akrylamidu\nZakres:\nZakres (0,0070 – 0,14) mg/m3\nZakres (0,00084 – 0,017) mg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC UV)","reference":"PN-Z-04486:2017-10","norm_bases":["PN-Z-04486:2017-10"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze * Stężenie/zawartość akrylamidu\nZakres:\nZakres (0,0070 – 0,14) mg/m3\nZakres (0,00084 – 0,017) mg w próbce\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC UV) PN-Z-04486:2017-10 Srodowisko pracy - powietrze * Stezenie/zawartosc akrylamidu\nZakres:\nZakres (0,0070 – 0,14) mg/m3\nZakres (0,00084 – 0,017) mg w probce\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC UV) PN-Z-04486:2017-10","categories":["environment"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of acrylamide","parameters_en":[{"name":"Range","range":"(0,0070 – 0,14) mg/m3"},{"name":"Range","range":"(0,00084 – 0,017) mg w próbce"}],"search_en":"Workplace environment - air * Concentration/content of acrylamide Range Range PN-Z-04486:2017-10","test_object_en":"Workplace environment - air *","parameters_zh":[{"name":"范围","range":"(0,0070 – 0,14) mg/m3"},{"name":"范围","range":"(0,00084 – 0,017) mg w próbce"}],"search_zh":"工作环境 － 空气 * 范围 范围 PN-Z-04486:2017-10","test_object_zh":"工作环境 － 空气 *"},{"_id":"6a82cee5884ede9a1b2c2edb","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - powietrze *","methodology":"Stężenie/zawartość hydrazyny","parameters":[{"name":"Zakres","range":"(0,00125 – 0,0769) mg/m3"},{"name":"Zakres","range":"(0,00094 – 0,0568) ppm"},{"name":"Zakres","range":"(0,00030 – 0,0070) mg w próbce"},{"name":"Zakres","range":"(0,00023 – 0,053) ppm"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC UV)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC UV)"],"computed":[],"activity":"Stężenie/zawartość hydrazyny\nZakres:\nZakres (0,00125 – 0,0769) mg/m3\nZakres (0,00094 – 0,0568) ppm\nZakres (0,00030 – 0,0070) mg w próbce\nZakres (0,00023 – 0,053) ppm\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC UV)","reference":"PN-Z-04523:2020-12","norm_bases":["PN-Z-04523:2020-12"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze * Stężenie/zawartość hydrazyny\nZakres:\nZakres (0,00125 – 0,0769) mg/m3\nZakres (0,00094 – 0,0568) ppm\nZakres (0,00030 – 0,0070) mg w próbce\nZakres (0,00023 – 0,053) ppm\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC UV) PN-Z-04523:2020-12 Srodowisko pracy - powietrze * Stezenie/zawartosc hydrazyny\nZakres:\nZakres (0,00125 – 0,0769) mg/m3\nZakres (0,00094 – 0,0568) ppm\nZakres (0,00030 – 0,0070) mg w probce\nZakres (0,00023 – 0,053) ppm\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC UV) PN-Z-04523:2020-12","categories":["environment"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,00125 – 0,0769) mg/m3"},{"name":"Range","range":"(0,00094 – 0,0568) ppm"},{"name":"Range","range":"(0,00030 – 0,0070) mg w próbce"},{"name":"Range","range":"(0,00023 – 0,053) ppm"}],"search_en":"Workplace environment - air * Range Range Range Range PN-Z-04523:2020-12","test_object_en":"Workplace environment - air *","parameters_zh":[{"name":"范围","range":"(0,00125 – 0,0769) mg/m3"},{"name":"范围","range":"(0,00094 – 0,0568) ppm"},{"name":"范围","range":"(0,00030 – 0,0070) mg w próbce"},{"name":"范围","range":"(0,00023 – 0,053) ppm"}],"search_zh":"工作环境 － 空气 * 范围 范围 范围 范围 PN-Z-04523:2020-12","test_object_zh":"工作环境 － 空气 *"},{"_id":"6a82cee5884ede9a1b2c2edc","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - powietrze *","methodology":"Stężenie/zawartość formaldehydu","parameters":[{"name":"Zakres","range":"(0,0133 – 60) mg/m3"},{"name":"Zakres","range":"(0,00040 – 0,0600) mg w próbce"},{"name":"UV"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją"],"computed":[],"activity":"Stężenie/zawartość formaldehydu\nZakres:\nZakres (0,0133 – 60) mg/m3\nZakres (0,00040 – 0,0600) mg w próbce\nUV\nMetoda wysokosprawnej chromatografii cieczowej z detekcją","reference":"Podstawy i Metody Oceny Środowiska Pracy 1999, nr 22, s. 96 - 100","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 1999, nr 22, s. 96 - 100"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze * Stężenie/zawartość formaldehydu\nZakres:\nZakres (0,0133 – 60) mg/m3\nZakres (0,00040 – 0,0600) mg w próbce\nUV\nMetoda wysokosprawnej chromatografii cieczowej z detekcją Podstawy i Metody Oceny Środowiska Pracy 1999, nr 22, s. 96 - 100 Srodowisko pracy - powietrze * Stezenie/zawartosc formaldehydu\nZakres:\nZakres (0,0133 – 60) mg/m3\nZakres (0,00040 – 0,0600) mg w probce\nUV\nMetoda wysokosprawnej chromatografii cieczowej z detekcja Podstawy i Metody Oceny Srodowiska Pracy 1999, nr 22, s. 96 - 100","categories":["environment"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Formaldehyde concentration/content","parameters_en":[{"name":"Range","range":"(0,0133 – 60) mg/m3"},{"name":"Range","range":"(0,00040 – 0,0600) mg w próbce"},{"name":"UV"}],"search_en":"Workplace environment - air * Formaldehyde concentration/content Range Range Podstawy i Metody Oceny Środowiska Pracy 1999, nr 22, s. 96 - 100","test_object_en":"Workplace environment - air *","parameters_zh":[{"name":"范围","range":"(0,0133 – 60) mg/m3"},{"name":"范围","range":"(0,00040 – 0,0600) mg w próbce"},{"name":"UV"}],"search_zh":"工作环境 － 空气 * 甲醛浓度/含量 范围 范围 Podstawy i Metody Oceny Środowiska Pracy 1999, nr 22, s. 96 - 100","methodology_zh":"甲醛浓度/含量","test_object_zh":"工作环境 － 空气 *"},{"_id":"6a82cee5884ede9a1b2c2edd","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - powietrze *","methodology":"Stężenie/zawartość chloru","parameters":[{"name":"Zakres","range":"(0,12 – 8) mg/m3"},{"name":"Zakres","range":"(0,0005 – 0,008) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość chloru\nZakres:\nZakres (0,12 – 8) mg/m3\nZakres (0,0005 – 0,008) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-75/Z-04037/03","norm_bases":["PN-75/Z-04037/03"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze * Stężenie/zawartość chloru\nZakres:\nZakres (0,12 – 8) mg/m3\nZakres (0,0005 – 0,008) mg w próbce\nMetoda spektrofotometryczna PN-75/Z-04037/03 Srodowisko pracy - powietrze * Stezenie/zawartosc chloru\nZakres:\nZakres (0,12 – 8) mg/m3\nZakres (0,0005 – 0,008) mg w probce\nMetoda spektrofotometryczna PN-75/Z-04037/03","categories":["environment"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chlorine concentration/content","parameters_en":[{"name":"Range","range":"(0,12 – 8) mg/m3"},{"name":"Range","range":"(0,0005 – 0,008) mg w próbce"}],"search_en":"Workplace environment - air * Chlorine concentration/content Spectrophotometric method Range Range PN-75/Z-04037/03","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment - air *","parameters_zh":[{"name":"范围","range":"(0,12 – 8) mg/m3"},{"name":"范围","range":"(0,0005 – 0,008) mg w próbce"}],"search_zh":"工作环境 － 空气 * 氯的浓度/含量 分光光度法 范围 范围 PN-75/Z-04037/03","technique_zh":"分光光度法","methodology_zh":"氯的浓度/含量","test_object_zh":"工作环境 － 空气 *"},{"_id":"6a82cee5884ede9a1b2c2ede","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - powietrze *","methodology":"Stężenie/zawartość chlorowodoru","parameters":[{"name":"Zakres","range":"(0,5 – 10) mg/m3"},{"name":"Zakres","range":"(0,20 – 4,0) mg w próbce"}],"technique":"Metoda turbidymetryczna","techniques":["Metoda turbidymetryczna"],"computed":[],"activity":"Stężenie/zawartość chlorowodoru\nZakres:\nZakres (0,5 – 10) mg/m3\nZakres (0,20 – 4,0) mg w próbce\nMetoda turbidymetryczna","reference":"PN-Z-04450:2014-08","norm_bases":["PN-Z-04450:2014-08"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze * Stężenie/zawartość chlorowodoru\nZakres:\nZakres (0,5 – 10) mg/m3\nZakres (0,20 – 4,0) mg w próbce\nMetoda turbidymetryczna PN-Z-04450:2014-08 Srodowisko pracy - powietrze * Stezenie/zawartosc chlorowodoru\nZakres:\nZakres (0,5 – 10) mg/m3\nZakres (0,20 – 4,0) mg w probce\nMetoda turbidymetryczna PN-Z-04450:2014-08","categories":["environment"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen chloride concentration/content","parameters_en":[{"name":"Range","range":"(0,5 – 10) mg/m3"},{"name":"Range","range":"(0,20 – 4,0) mg w próbce"}],"search_en":"Workplace environment - air * Hydrogen chloride concentration/content Turbidimetric method Range Range PN-Z-04450:2014-08","technique_en":"Turbidimetric method","test_object_en":"Workplace environment - air *","parameters_zh":[{"name":"范围","range":"(0,5 – 10) mg/m3"},{"name":"范围","range":"(0,20 – 4,0) mg w próbce"}],"search_zh":"工作环境 － 空气 * 氯化氢的浓度/含量 浊度法 范围 范围 PN-Z-04450:2014-08","technique_zh":"浊度法","methodology_zh":"氯化氢的浓度/含量","test_object_zh":"工作环境 － 空气 *"},{"_id":"6a82cee5884ede9a1b2c2edf","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - powietrze *","methodology":"Stężenie/zawartość amoniaku","parameters":[{"name":"Zakres","range":"(1,25– 60) mg/m3"},{"name":"Zakres","range":"(0,015 – 0,30) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość amoniaku\nZakres:\nZakres (1,25– 60) mg/m3\nZakres (0,015 – 0,30) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04041:1971","norm_bases":["PN-Z-04041:1971"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze * Stężenie/zawartość amoniaku\nZakres:\nZakres (1,25– 60) mg/m3\nZakres (0,015 – 0,30) mg w próbce\nMetoda spektrofotometryczna PN-Z-04041:1971 Srodowisko pracy - powietrze * Stezenie/zawartosc amoniaku\nZakres:\nZakres (1,25– 60) mg/m3\nZakres (0,015 – 0,30) mg w probce\nMetoda spektrofotometryczna PN-Z-04041:1971","categories":["environment"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonia concentration/content","parameters_en":[{"name":"Range","range":"(1,25– 60) mg/m3"},{"name":"Range","range":"(0,015 – 0,30) mg w próbce"}],"search_en":"Workplace environment - air * Ammonia concentration/content Spectrophotometric method Range Range PN-Z-04041:1971","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment - air *","parameters_zh":[{"name":"范围","range":"(1,25– 60) mg/m3"},{"name":"范围","range":"(0,015 – 0,30) mg w próbce"}],"search_zh":"工作环境 － 空气 * 氨浓度/含量 分光光度法 范围 范围 PN-Z-04041:1971","technique_zh":"分光光度法","methodology_zh":"氨浓度/含量","test_object_zh":"工作环境 － 空气 *"},{"_id":"6a82cee5884ede9a1b2c2ee0","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - powietrze *","methodology":"Stężenie/zawartość olejów mineralnych wysokorafinowanych z wyłączeniem cieczy obróbkowych","parameters":[{"name":"Zakres","range":"(0,42 – 41,7) mg/m3"},{"name":"Zakres","range":"(0,30 – 10,0) mg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość olejów mineralnych wysokorafinowanych z wyłączeniem cieczy obróbkowych\nZakres:\nZakres (0,42 – 41,7) mg/m3\nZakres (0,30 – 10,0) mg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04108-6:2006 | PN-Z-04108-6:2006/Az1:2009","norm_bases":["PN-Z-04108-6:2006","PN-Z-04108-6:2006/Az1:2009"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze * Stężenie/zawartość olejów mineralnych wysokorafinowanych z wyłączeniem cieczy obróbkowych\nZakres:\nZakres (0,42 – 41,7) mg/m3\nZakres (0,30 – 10,0) mg w próbce\nMetoda spektrofotometryczna PN-Z-04108-6:2006 | PN-Z-04108-6:2006/Az1:2009 Srodowisko pracy - powietrze * Stezenie/zawartosc olejow mineralnych wysokorafinowanych z wylaczeniem cieczy obrobkowych\nZakres:\nZakres (0,42 – 41,7) mg/m3\nZakres (0,30 – 10,0) mg w probce\nMetoda spektrofotometryczna PN-Z-04108-6:2006 | PN-Z-04108-6:2006/Az1:2009","categories":["environment","petro"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration/content of highly refined mineral oils excluding metalworking fluids","parameters_en":[{"name":"Range","range":"(0,42 – 41,7) mg/m3"},{"name":"Range","range":"(0,30 – 10,0) mg w próbce"}],"search_en":"Workplace environment - air * Concentration/content of highly refined mineral oils excluding metalworking fluids Spectrophotometric method Range Range PN-Z-04108-6:2006 | PN-Z-04108-6:2006/Az1:2009","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment - air *","parameters_zh":[{"name":"范围","range":"(0,42 – 41,7) mg/m3"},{"name":"范围","range":"(0,30 – 10,0) mg w próbce"}],"search_zh":"工作环境 － 空气 * 分光光度法 范围 范围 PN-Z-04108-6:2006 | PN-Z-04108-6:2006/Az1:2009","technique_zh":"分光光度法","test_object_zh":"工作环境 － 空气 *"},{"_id":"6a82cee5884ede9a1b2c2ee1","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[{"name":"Temperatura pobranej próbki ścieków"},{"name":"Zakres","range":"(0,5 – 50) oC"}],"technique":"Metoda manualna","techniques":["Metoda manualna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki ścieków\nZakres (0,5 – 50) oC\nMetoda manualna","reference":"PN-ISO 5667-10:2021-11 | PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11","PN-77/C-04584"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki ścieków\nZakres (0,5 – 50) oC\nMetoda manualna PN-ISO 5667-10:2021-11 | PN-77/C-04584 Scieki Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura pobranej probki sciekow\nZakres (0,5 – 50) oC\nMetoda manualna PN-ISO 5667-10:2021-11 | PN-77/C-04584","categories":["water"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","parameters_en":[{"name":"Temperature of the collected wastewater sample"},{"name":"Range","range":"(0,5 – 50) oC"}],"search_en":"Wastewater Sampling for chemical and physical testing Manual method Temperature of the collected wastewater sample Range PN-ISO 5667-10:2021-11 | PN-77/C-04584","technique_en":"Manual method","test_object_en":"Wastewater","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"所采废水样品的温度"},{"name":"范围","range":"(0,5 – 50) oC"}],"search_zh":"污水 化学与物理检测用样品采集 手工法 所采废水样品的温度 范围 PN-ISO 5667-10:2021-11 | PN-77/C-04584","test_object_zh":"污水","technique_zh":"手工法"},{"_id":"6a82cee5884ede9a1b2c2ee2","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007 + Ap1:2007","norm_bases":["PN-EN 872:2007 + Ap1:2007"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Zawiesiny ogólne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007 + Ap1:2007 Scieki Zawiesiny ogolne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007 + Ap1:2007","categories":["water"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 1000) mg/l"}],"search_en":"Wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007 + Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 1000) mg/l"}],"search_zh":"污水 总悬浮物 重量法 范围 PN-EN 872:2007 + Ap1:2007","technique_zh":"重量法","test_object_zh":"污水"},{"_id":"6a82cee5884ede9a1b2c2ee3","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie substancji ekstrahujących się eterem naftowym","parameters":[{"name":"Zakres","range":"(2,0 – 100) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie substancji ekstrahujących się eterem naftowym\nZakres (2,0 – 100) mg/l\nMetoda wagowa","reference":"EHS-PB-3 wyd. 2 z 20.08.15","norm_bases":["EHS-PB-3 wyd. 2 z 20.08.15"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie substancji ekstrahujących się eterem naftowym\nZakres (2,0 – 100) mg/l\nMetoda wagowa EHS-PB-3 wyd. 2 z 20.08.15 Scieki Stezenie substancji ekstrahujacych sie eterem naftowym\nZakres (2,0 – 100) mg/l\nMetoda wagowa EHS-PB-3 wyd. 2 z 20.08.15","categories":["water"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of substances extractable with petroleum ether","parameters_en":[{"name":"Range","range":"(2,0 – 100) mg/l"}],"search_en":"Wastewater Concentration of substances extractable with petroleum ether Gravimetric method Range EHS-PB-3 wyd. 2 z 20.08.15","technique_en":"Gravimetric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(2,0 – 100) mg/l"}],"search_zh":"污水 石油醚可萃取物浓度 重量法 范围 EHS-PB-3 wyd. 2 z 20.08.15","technique_zh":"重量法","test_object_zh":"污水","methodology_zh":"石油醚可萃取物浓度"},{"_id":"6a82cee5884ede9a1b2c2ee4","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Ścieki","methodology":"Zawiesina łatwoopadająca","parameters":[{"name":"Zakres","range":"(0,5 – 100) ml/l"}],"technique":"Metoda objętościowa","techniques":["Metoda objętościowa"],"computed":[],"activity":"Zawiesina łatwoopadająca\nZakres (0,5 – 100) ml/l\nMetoda objętościowa","reference":"PN-C-04559-03:1972","norm_bases":["PN-C-04559-03:1972"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Zawiesina łatwoopadająca\nZakres (0,5 – 100) ml/l\nMetoda objętościowa PN-C-04559-03:1972 Scieki Zawiesina latwoopadajaca\nZakres (0,5 – 100) ml/l\nMetoda objetosciowa PN-C-04559-03:1972","categories":["water"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Settleable solids","parameters_en":[{"name":"Range","range":"(0,5 – 100) ml/l"}],"search_en":"Wastewater Settleable solids Volumetric method Range PN-C-04559-03:1972","technique_en":"Volumetric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(0,5 – 100) ml/l"}],"search_zh":"污水 容量法 范围 PN-C-04559-03:1972","test_object_zh":"污水","technique_zh":"容量法"},{"_id":"6a82cee5884ede9a1b2c2ee5","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Woda","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody","parameters":[{"name":"Zakres","range":"(0,5 – 50) oC"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody\nZakres (0,5 – 50) oC","reference":"PN-ISO 5667-6:2016-12 | PN-77/C-04584","norm_bases":["PN-ISO 5667-6:2016-12","PN-77/C-04584"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody\nZakres (0,5 – 50) oC PN-ISO 5667-6:2016-12 | PN-77/C-04584 Woda Pobieranie probek do badan chemicznych i fizycznych Temperatura pobranej probki wody\nZakres (0,5 – 50) oC PN-ISO 5667-6:2016-12 | PN-77/C-04584","categories":["water"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing Temperature of the water sample taken","parameters_en":[{"name":"Range","range":"(0,5 – 50) oC"}],"search_en":"Water Sampling for chemical and physical testing Temperature of the water sample taken Range PN-ISO 5667-6:2016-12 | PN-77/C-04584","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,5 – 50) oC"}],"search_zh":"水 化学和物理检测采样 所采水样的温度 范围 PN-ISO 5667-6:2016-12 | PN-77/C-04584","test_object_zh":"水","methodology_zh":"化学和物理检测采样 所采水样的温度"},{"_id":"6a82cee5884ede9a1b2c2ee6","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Woda","methodology":"Zasadowość ogólna","parameters":[{"name":"Zakres","range":"(0,4 – 40) mmol/l"},{"name":"Zakres","range":"(20 – 2000) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zasadowość ogólna\nZakres:\nZakres (0,4 – 40) mmol/l\nZakres (20 – 2000) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-EN ISO 9963-1:2001+Ap1:2004","norm_bases":["PN-EN ISO 9963-1:2001+Ap1:2004"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Zasadowość ogólna\nZakres:\nZakres (0,4 – 40) mmol/l\nZakres (20 – 2000) mg/l CaCO3\nMetoda miareczkowa PN-EN ISO 9963-1:2001+Ap1:2004 Woda Zasadowosc ogolna\nZakres:\nZakres (0,4 – 40) mmol/l\nZakres (20 – 2000) mg/l CaCO3\nMetoda miareczkowa PN-EN ISO 9963-1:2001+Ap1:2004","categories":["water"],"row_index":73,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total alkalinity","parameters_en":[{"name":"Range","range":"(0,4 – 40) mmol/l"},{"name":"Range","range":"(20 – 2000) mg/l CaCO3"}],"search_en":"Water Total alkalinity Titrimetric method Range Range PN-EN ISO 9963-1:2001+Ap1:2004","technique_en":"Titrimetric method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,4 – 40) mmol/l"},{"name":"范围","range":"(20 – 2000) mg/l CaCO3"}],"search_zh":"水 总碱度 滴定法 范围 范围 PN-EN ISO 9963-1:2001+Ap1:2004","technique_zh":"滴定法","test_object_zh":"水","methodology_zh":"总碱度"},{"_id":"6a82cee5884ede9a1b2c2ee7","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Woda i ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"(2,0 – 12,0)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres (2,0 – 12,0)\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda i ścieki pH\nZakres (2,0 – 12,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda i scieki pH\nZakres (2,0 – 12,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":74,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"(2,0 – 12,0)"}],"search_en":"Water and wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water and wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"(2,0 – 12,0)"}],"search_zh":"水与废水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水与废水"},{"_id":"6a82cee5884ede9a1b2c2ee8","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Woda i ścieki","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(10 – 12880) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (10 – 12880) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda i ścieki Przewodność elektryczna właściwa\nZakres (10 – 12880) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda i scieki Przewodnosc elektryczna wlasciwa\nZakres (10 – 12880) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":75,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(10 – 12880) μS/cm"}],"search_en":"Water and wastewater Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water and wastewater","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(10 – 12880) μS/cm"}],"search_zh":"水与废水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水与废水"},{"_id":"6a82cee5884ede9a1b2c2ee9","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Woda i ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,0 – 1000) mg/I"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,0 – 1000) mg/I\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda i ścieki Stężenie chlorków\nZakres (5,0 – 1000) mg/I\nMetoda miareczkowa PN-ISO 9297:1994 Woda i scieki Stezenie chlorkow\nZakres (5,0 – 1000) mg/I\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":76,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,0 – 1000) mg/I"}],"search_en":"Water and wastewater Chloride concentration Titrimetric method Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water and wastewater","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 1000) mg/I"}],"search_zh":"水与废水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水与废水"},{"_id":"6a82cee5884ede9a1b2c2eea","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Woda i ścieki","methodology":"Stężenie żelaza ogólnego","parameters":[{"name":"Zakres","range":"(0,01 – 20) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza ogólnego\nZakres (0,01 – 20) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda i ścieki Stężenie żelaza ogólnego\nZakres (0,01 – 20) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 Woda i scieki Stezenie zelaza ogolnego\nZakres (0,01 – 20) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":77,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total iron concentration","parameters_en":[{"name":"Range","range":"(0,01 – 20) mg/l"}],"search_en":"Water and wastewater Total iron concentration Spectrophotometric method Range PN-ISO 6332:2001+Ap1:2016-06","technique_en":"Spectrophotometric method","test_object_en":"Water and wastewater","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(0,01 – 20) mg/l"}],"search_zh":"水与废水 总铁浓度 分光光度法 范围 PN-ISO 6332:2001+Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"水与废水"},{"_id":"6a82cee5884ede9a1b2c2eeb","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Woda i ścieki","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,01 – 40) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotynów\nZakres (0,01 – 40) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda i ścieki Stężenie azotynów\nZakres (0,01 – 40) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda i scieki Stezenie azotynow\nZakres (0,01 – 40) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":78,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite concentration","parameters_en":[{"name":"Range","range":"(0,01 – 40) mg/l"}],"search_en":"Water and wastewater Nitrite concentration Spectrophotometric method Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water and wastewater","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,01 – 40) mg/l"}],"search_zh":"水与废水 亚硝酸盐浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水与废水"},{"_id":"6a82cee5884ede9a1b2c2eec","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Woda i ścieki","methodology":"Indeks fenolowy","parameters":[{"name":"Zakres","range":"(0,01 – 50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Indeks fenolowy\nZakres (0,01 – 50) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6439:1994, pkt 4","norm_bases":["PN-ISO 6439:1994, pkt 4"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda i ścieki Indeks fenolowy\nZakres (0,01 – 50) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994, pkt 4 Woda i scieki Indeks fenolowy\nZakres (0,01 – 50) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994, pkt 4","categories":["water"],"row_index":79,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phenol index","parameters_en":[{"name":"Range","range":"(0,01 – 50) mg/l"}],"search_en":"Water and wastewater Phenol index Spectrophotometric method Range PN-ISO 6439:1994, pkt 4","technique_en":"Spectrophotometric method","test_object_en":"Water and wastewater","parameters_zh":[{"name":"范围","range":"(0,01 – 50) mg/l"}],"search_zh":"水与废水 酚指数 分光光度法 范围 PN-ISO 6439:1994, pkt 4","technique_zh":"分光光度法","methodology_zh":"酚指数","test_object_zh":"水与废水"},{"_id":"6a82cee5884ede9a1b2c2eed","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Woda i ścieki","methodology":"Chemiczne zapotrzebowanie tlenu – ChZT","parameters":[{"name":"Zakres","range":"(10,0 – 1000) mg/I O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu – ChZT\nZakres (10,0 – 1000) mg/I O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda i ścieki Chemiczne zapotrzebowanie tlenu – ChZT\nZakres (10,0 – 1000) mg/I O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda i scieki Chemiczne zapotrzebowanie tlenu – ChZT\nZakres (10,0 – 1000) mg/I O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":80,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand – COD","parameters_en":[{"name":"Range","range":"(10,0 – 1000) mg/I O2"}],"search_en":"Water and wastewater Chemical oxygen demand – COD Spectrophotometric method Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Water and wastewater","parameters_zh":[{"name":"范围","range":"(10,0 – 1000) mg/I O2"}],"search_zh":"水与废水 化学需氧量 － COD 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水与废水","methodology_zh":"化学需氧量 － COD"},{"_id":"6a82cee5884ede9a1b2c2eee","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Woda i ścieki","methodology":"Stężenie fosforanów","parameters":[{"name":"Zakres","range":"(0,01 – 50) mg/l"},{"name":"Zakres","range":"(0,03 – 153) mg/l P-PO4"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforanów\nZakres:\nZakres (0,01 – 50) mg/l\nZakres (0,03 – 153) mg/l P-PO4\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda i ścieki Stężenie fosforanów\nZakres:\nZakres (0,01 – 50) mg/l\nZakres (0,03 – 153) mg/l P-PO4\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010 Woda i scieki Stezenie fosforanow\nZakres:\nZakres (0,01 – 50) mg/l\nZakres (0,03 – 153) mg/l P-PO4\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010","categories":["water"],"row_index":81,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phosphate concentration","parameters_en":[{"name":"Range","range":"(0,01 – 50) mg/l"},{"name":"Range","range":"(0,03 – 153) mg/l P-PO4"}],"search_en":"Water and wastewater Phosphate concentration Spectrophotometric method Range Range PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water and wastewater","parameters_zh":[{"name":"范围","range":"(0,01 – 50) mg/l"},{"name":"范围","range":"(0,03 – 153) mg/l P-PO4"}],"search_zh":"水与废水 磷酸盐浓度 分光光度法 范围 范围 PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水与废水","methodology_zh":"磷酸盐浓度"},{"_id":"6a82cee5884ede9a1b2c2eef","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Woda i ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,04 – 30) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,04 – 30) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda i ścieki Stężenie fosforu ogólnego\nZakres (0,04 – 30) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010 Woda i scieki Stezenie fosforu ogolnego\nZakres (0,04 – 30) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010","categories":["water"],"row_index":82,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,04 – 30) mg/l"}],"search_en":"Water and wastewater Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water and wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,04 – 30) mg/l"}],"search_zh":"水与废水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水与废水"},{"_id":"6a82cee5884ede9a1b2c2ef0","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Woda i ścieki","methodology":"Stężenie azotu amonowego, jonu amonowego","parameters":[{"name":"azot amonowy"},{"name":"Zakres","range":"(0,050 – 325) mg/l"},{"name":"jon amonowy"},{"name":"Zakres","range":"(0,064 – 418) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego, jonu amonowego\nZakres:\nazot amonowy\nZakres (0,050 – 325) mg/l\njon amonowy\nZakres (0,064 – 418) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda i ścieki Stężenie azotu amonowego, jonu amonowego\nZakres:\nazot amonowy\nZakres (0,050 – 325) mg/l\njon amonowy\nZakres (0,064 – 418) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda i scieki Stezenie azotu amonowego, jonu amonowego\nZakres:\nazot amonowy\nZakres (0,050 – 325) mg/l\njon amonowy\nZakres (0,064 – 418) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":83,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"ammonium nitrogen"},{"name":"Range","range":"(0,050 – 325) mg/l"},{"name":"ammonium ion"},{"name":"Range","range":"(0,064 – 418) mg/l"}],"search_en":"Water and wastewater Spectrophotometric method ammonium nitrogen Range ammonium ion Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water and wastewater","parameters_zh":[{"name":"铵态氮"},{"name":"范围","range":"(0,050 – 325) mg/l"},{"name":"jon amonowy"},{"name":"范围","range":"(0,064 – 418) mg/l"}],"search_zh":"水与废水 分光光度法 铵态氮 范围 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水与废水"},{"_id":"6a82cee5884ede9a1b2c2ef1","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Woda i ścieki","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(5 – 600) mg/l"}],"technique":"Metoda turbidymetryczna","techniques":["Metoda turbidymetryczna"],"computed":[],"activity":"Stężenie siarczanów\nZakres (5 – 600) mg/l\nMetoda turbidymetryczna","reference":"EHS-PB-50 wyd. 1 z 05.06.2017 r. | na podstawie metody HACH nr 8051","norm_bases":["EHS-PB-50 wyd. 1 z 05.06.2017 r.","na podstawie metody HACH nr 8051"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda i ścieki Stężenie siarczanów\nZakres (5 – 600) mg/l\nMetoda turbidymetryczna EHS-PB-50 wyd. 1 z 05.06.2017 r. | na podstawie metody HACH nr 8051 Woda i scieki Stezenie siarczanow\nZakres (5 – 600) mg/l\nMetoda turbidymetryczna EHS-PB-50 wyd. 1 z 05.06.2017 r. | na podstawie metody HACH nr 8051","categories":["water"],"row_index":84,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(5 – 600) mg/l"}],"search_en":"Water and wastewater Sulfate concentration Turbidimetric method Range EHS-PB-50 wyd. 1 z 05.06.2017 r. | na podstawie metody HACH nr 8051","technique_en":"Turbidimetric method","test_object_en":"Water and wastewater","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(5 – 600) mg/l"}],"search_zh":"水与废水 硫酸盐浓度 浊度法 范围 EHS-PB-50 wyd. 1 z 05.06.2017 r. | na podstawie metody HACH nr 8051","technique_zh":"浊度法","test_object_zh":"水与废水"},{"_id":"6a82cee5884ede9a1b2c2ef2","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Woda i ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","parameters":[{"name":"Zakres","range":"(1 – 6000) mg/I O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1 – 6000) mg/I O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda i ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1 – 6000) mg/I O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda i scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1 – 6000) mg/I O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":85,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand - BOD5","parameters_en":[{"name":"Range","range":"(1 – 6000) mg/I O2"}],"search_en":"Water and wastewater Biochemical oxygen demand - BOD5 Electrochemical method Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Water and wastewater","parameters_zh":[{"name":"范围","range":"(1 – 6000) mg/I O2"}],"search_zh":"水与废水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","methodology_zh":"五日生化需氧量（BOD5）","test_object_zh":"水与废水"},{"_id":"6a82cee5884ede9a1b2c2ef3","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Woda i ścieki","methodology":"Indeks oleju mineralnego","parameters":[{"name":"Zakres","range":"(0,10 – 50) mg/I"},{"name":"GC-FID"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną"],"computed":[],"activity":"Indeks oleju mineralnego\nZakres:\nZakres (0,10 – 50) mg/I\nGC-FID\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną","reference":"PN-EN ISO 9377-2:2003","norm_bases":["PN-EN ISO 9377-2:2003"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda i ścieki Indeks oleju mineralnego\nZakres:\nZakres (0,10 – 50) mg/I\nGC-FID\nMetoda chromatografii gazowej z detekcją płomieniowo – jonizacyjną PN-EN ISO 9377-2:2003 Woda i scieki Indeks oleju mineralnego\nZakres:\nZakres (0,10 – 50) mg/I\nGC-FID\nMetoda chromatografii gazowej z detekcja plomieniowo – jonizacyjna PN-EN ISO 9377-2:2003","categories":["water","petro"],"row_index":86,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mineral oil index","parameters_en":[{"name":"Range","range":"(0,10 – 50) mg/I"},{"name":"GC-FID"}],"search_en":"Water and wastewater Mineral oil index Range GC-FID PN-EN ISO 9377-2:2003","test_object_en":"Water and wastewater","parameters_zh":[{"name":"范围","range":"(0,10 – 50) mg/I"},{"name":"GC-FID"}],"search_zh":"水与废水 矿物油指数 范围 PN-EN ISO 9377-2:2003","methodology_zh":"矿物油指数","test_object_zh":"水与废水"},{"_id":"6a82cee5884ede9a1b2c2ef4","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - hałas *","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(24 - 135) dB"},{"name":"Szczytowy poziom dźwięku C"},{"name":"Zakres","range":"(40 - 138) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (24 - 135) dB\nSzczytowy poziom dźwięku C\nZakres (40 - 138) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących strategię 2 i 3 – punkt 10 i 11 | PN-N-01307:1994","norm_bases":["PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących strategię 2 i 3 – punkt 10 i 11","PN-N-01307:1994"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas * Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (24 - 135) dB\nSzczytowy poziom dźwięku C\nZakres (40 - 138) dB\nMetoda pomiarowa bezpośrednia PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących strategię 2 i 3 – punkt 10 i 11 | PN-N-01307:1994 Srodowisko pracy - halas * Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres:\nZakres (24 - 135) dB\nSzczytowy poziom dzwieku C\nZakres (40 - 138) dB\nMetoda pomiarowa bezposrednia PN-EN ISO 9612:2011 z wylaczeniem metod obejmujacych strategie 2 i 3 – punkt 10 i 11 | PN-N-01307:1994","categories":["environment"],"row_index":87,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters_en":[{"name":"Range","range":"(24 - 135) dB"},{"name":"C-weighted peak sound pressure level"},{"name":"Range","range":"(40 - 138) dB"}],"search_en":"A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method Range C-weighted peak sound pressure level Range PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących strategię 2 i 3 – punkt 10 i 11 | PN-N-01307:1994","technique_en":"Direct measurement method","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(24 - 135) dB"},{"name":"C 计权峰值声级"},{"name":"范围","range":"(40 - 138) dB"}],"search_zh":"A 计权等效声级 A 计权最大声级 直接测量法 范围 C 计权峰值声级 范围 PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących strategię 2 i 3 – punkt 10 i 11 | PN-N-01307:1994","technique_zh":"直接测量法"},{"_id":"6a82cee5884ede9a1b2c2ef5","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - hałas *","methodology":"Poziom ekspozycji na hałas odniesiony do:","parameters":[{"name":"8-godz. dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących strategię 2 i 3 – punkt 10 i 11 | PN-N-01307:1994","norm_bases":["PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących strategię 2 i 3 – punkt 10 i 11","PN-N-01307:1994"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas * Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących strategię 2 i 3 – punkt 10 i 11 | PN-N-01307:1994 Srodowisko pracy - halas * Poziom ekspozycji na halas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-EN ISO 9612:2011 z wylaczeniem metod obejmujacych strategie 2 i 3 – punkt 10 i 11 | PN-N-01307:1994","categories":["environment"],"row_index":88,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Noise exposure level referred to:","parameters_en":[{"name":"an 8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"search_en":"Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated) PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących strategię 2 i 3 – punkt 10 i 11 | PN-N-01307:1994","methodology_zh":"噪声暴露级，参照：","parameters_zh":[{"name":"8 小时日工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"噪声暴露级，参照： 8 小时日工作时间 平均每周工作时间（计算值） PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących strategię 2 i 3 – punkt 10 i 11 | PN-N-01307:1994"},{"_id":"6a82cee5884ede9a1b2c2ef6","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie miejsce pracy światłem elektrycznym *","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(5 – 5000) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (5 – 5000) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie miejsce pracy światłem elektrycznym * Natężenie oświetlenia\nZakres (5 – 5000) lx\nMetoda pomiarowa bezpośrednia PN-83/E-04040.03 Srodowisko pracy - oswietlenie miejsce pracy swiatlem elektrycznym * Natezenie oswietlenia\nZakres (5 – 5000) lx\nMetoda pomiarowa bezposrednia PN-83/E-04040.03","categories":["environment"],"row_index":89,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance","parameters_en":[{"name":"Range","range":"(5 – 5000) lx"}],"search_en":"Illuminance Direct measurement method Range PN-83/E-04040.03","technique_en":"Direct measurement method","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(5 – 5000) lx"}],"search_zh":"照度 直接测量法 范围 PN-83/E-04040.03","technique_zh":"直接测量法"},{"_id":"6a82cee5884ede9a1b2c2ef7","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie miejsce pracy światłem elektrycznym *","methodology":"Równomierność oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie miejsce pracy światłem elektrycznym * Równomierność oświetlenia (z obliczeń) PN-83/E-04040.03 Srodowisko pracy - oswietlenie miejsce pracy swiatlem elektrycznym * Rownomiernosc oswietlenia (z obliczen) PN-83/E-04040.03","categories":["environment"],"row_index":90,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance uniformity (calculated)","search_en":"Illuminance uniformity (calculated) PN-83/E-04040.03","methodology_zh":"照度均匀度（计算值）","search_zh":"照度均匀度（计算值） PN-83/E-04040.03"},{"_id":"6a82cee5884ede9a1b2c2ef8","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - powietrze *","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","parameters":[{"name":"pyły przemysłowe"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"},{"name":"substancje organiczne, w tym"},{"name":"frakcja wdychalna"},{"name":"substancje nieorganiczne, w tym"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"},{"name":"metale i ich związki, w tym"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\npyły przemysłowe\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje organiczne, w tym\nfrakcja wdychalna\nsubstancje nieorganiczne, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nmetale i ich związki, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze * Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\npyły przemysłowe\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje organiczne, w tym\nfrakcja wdychalna\nsubstancje nieorganiczne, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nmetale i ich związki, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy - powietrze * Pobieranie probek do oceny narazenia zawodowego na:\nZakres:\npyly przemyslowe\nfrakcja wdychalna\nfrakcja respirabilna\nsubstancje organiczne, w tym\nfrakcja wdychalna\nsubstancje nieorganiczne, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nmetale i ich zwiazki, w tym\nfrakcja wdychalna\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004","categories":["materials","environment"],"row_index":91,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"industrial dusts"},{"name":"inhalable fraction"},{"name":"respirable fraction"},{"name":"organic substances, including"},{"name":"inhalable fraction"},{"name":"inorganic substances, including"},{"name":"inhalable fraction"},{"name":"respirable fraction"},{"name":"metals and their compounds, including"},{"name":"inhalable fraction"},{"name":"respirable fraction"}],"search_en":"Workplace environment - air * Sampling for the assessment of occupational exposure to: Personal dosimetry method industrial dusts inhalable fraction respirable fraction organic substances, including inhalable fraction inorganic substances, including inhalable fraction respirable fraction metals and their compounds, including inhalable fraction respirable fraction PN-Z-04008-7:2002+Az1:2004","technique_en":"Personal dosimetry method","test_object_en":"Workplace environment - air *","methodology_zh":"职业接触评估采样，针对：","parameters_zh":[{"name":"工业粉尘"},{"name":"可吸入组分"},{"name":"呼吸性组分"},{"name":"有机物质，包括"},{"name":"可吸入组分"},{"name":"无机物质，包括"},{"name":"可吸入组分"},{"name":"呼吸性组分"},{"name":"金属及其化合物，包括"},{"name":"可吸入组分"},{"name":"呼吸性组分"}],"search_zh":"工作环境 － 空气 * 职业接触评估采样，针对： 个体剂量测定法 工业粉尘 可吸入组分 呼吸性组分 有机物质，包括 可吸入组分 无机物质，包括 可吸入组分 呼吸性组分 金属及其化合物，包括 可吸入组分 呼吸性组分 PN-Z-04008-7:2002+Az1:2004","technique_zh":"个体剂量测定法","test_object_zh":"工作环境 － 空气 *"},{"_id":"6a82cee5884ede9a1b2c2ef9","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Środowisko pracy - powietrze *","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze * Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy - powietrze * Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002+Az1:2004","categories":["environment"],"row_index":92,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Exposure index (calculated)","search_en":"Workplace environment - air * Exposure index (calculated) PN-Z-04008-7:2002+Az1:2004","test_object_en":"Workplace environment - air *","methodology_zh":"暴露指数（计算得出）","search_zh":"工作环境 － 空气 * 暴露指数（计算得出） PN-Z-04008-7:2002+Az1:2004","test_object_zh":"工作环境 － 空气 *"},{"_id":"6a82cee5884ede9a1b2c2efa","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[{"name":"Temperatura pobranej próbki ścieków"},{"name":"Zakres","range":"(0,5 – 50) oC"}],"technique":"Metoda manualna","techniques":["Metoda manualna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki ścieków\nZakres (0,5 – 50) oC\nMetoda manualna","reference":"PN-ISO 5667-10:2021-11 | PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11","PN-77/C-04584"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki ścieków\nZakres (0,5 – 50) oC\nMetoda manualna PN-ISO 5667-10:2021-11 | PN-77/C-04584 Scieki Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura pobranej probki sciekow\nZakres (0,5 – 50) oC\nMetoda manualna PN-ISO 5667-10:2021-11 | PN-77/C-04584","categories":["water"],"row_index":93,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","parameters_en":[{"name":"Temperature of the collected wastewater sample"},{"name":"Range","range":"(0,5 – 50) oC"}],"search_en":"Wastewater Sampling for chemical and physical testing Manual method Temperature of the collected wastewater sample Range PN-ISO 5667-10:2021-11 | PN-77/C-04584","technique_en":"Manual method","test_object_en":"Wastewater","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"所采废水样品的温度"},{"name":"范围","range":"(0,5 – 50) oC"}],"search_zh":"污水 化学与物理检测用样品采集 手工法 所采废水样品的温度 范围 PN-ISO 5667-10:2021-11 | PN-77/C-04584","test_object_zh":"污水","technique_zh":"手工法"},{"_id":"6a82cee5884ede9a1b2c2efb","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Woda","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody","parameters":[{"name":"Zakres","range":"(0,5 – 50) oC"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody\nZakres (0,5 – 50) oC","reference":"PN-ISO 5667-6:2016-02 | PN-77/C-04584","norm_bases":["PN-ISO 5667-6:2016-02","PN-77/C-04584"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody\nZakres (0,5 – 50) oC PN-ISO 5667-6:2016-02 | PN-77/C-04584 Woda Pobieranie probek do badan chemicznych i fizycznych Temperatura pobranej probki wody\nZakres (0,5 – 50) oC PN-ISO 5667-6:2016-02 | PN-77/C-04584","categories":["water"],"row_index":94,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing Temperature of the water sample taken","parameters_en":[{"name":"Range","range":"(0,5 – 50) oC"}],"search_en":"Water Sampling for chemical and physical testing Temperature of the water sample taken Range PN-ISO 5667-6:2016-02 | PN-77/C-04584","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,5 – 50) oC"}],"search_zh":"水 化学和物理检测采样 所采水样的温度 范围 PN-ISO 5667-6:2016-02 | PN-77/C-04584","test_object_zh":"水","methodology_zh":"化学和物理检测采样 所采水样的温度"},{"_id":"6a82cee5884ede9a1b2c2efc","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Woda","methodology":"Zasadowość ogólna","parameters":[{"name":"Zakres","range":"(0,4 – 40) mmol/l"},{"name":"Zakres","range":"(20 – 2000) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zasadowość ogólna\nZakres:\nZakres (0,4 – 40) mmol/l\nZakres (20 – 2000) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-EN ISO 9963-1:2001+Ap1:2004","norm_bases":["PN-EN ISO 9963-1:2001+Ap1:2004"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Zasadowość ogólna\nZakres:\nZakres (0,4 – 40) mmol/l\nZakres (20 – 2000) mg/l CaCO3\nMetoda miareczkowa PN-EN ISO 9963-1:2001+Ap1:2004 Woda Zasadowosc ogolna\nZakres:\nZakres (0,4 – 40) mmol/l\nZakres (20 – 2000) mg/l CaCO3\nMetoda miareczkowa PN-EN ISO 9963-1:2001+Ap1:2004","categories":["water"],"row_index":95,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total alkalinity","parameters_en":[{"name":"Range","range":"(0,4 – 40) mmol/l"},{"name":"Range","range":"(20 – 2000) mg/l CaCO3"}],"search_en":"Water Total alkalinity Titrimetric method Range Range PN-EN ISO 9963-1:2001+Ap1:2004","technique_en":"Titrimetric method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,4 – 40) mmol/l"},{"name":"范围","range":"(20 – 2000) mg/l CaCO3"}],"search_zh":"水 总碱度 滴定法 范围 范围 PN-EN ISO 9963-1:2001+Ap1:2004","technique_zh":"滴定法","test_object_zh":"水","methodology_zh":"总碱度"},{"_id":"6a82cee5884ede9a1b2c2efd","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Woda","methodology":"Zasadowość złożona","parameters":[{"name":"Zakres","range":"(0,2 – 20) mmol/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zasadowość złożona\nZakres (0,2 – 20) mmol/l\nMetoda miareczkowa","reference":"PN-EN ISO 9963-1:2001+Ap1:2004","norm_bases":["PN-EN ISO 9963-1:2001+Ap1:2004"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Zasadowość złożona\nZakres (0,2 – 20) mmol/l\nMetoda miareczkowa PN-EN ISO 9963-1:2001+Ap1:2004 Woda Zasadowosc zlozona\nZakres (0,2 – 20) mmol/l\nMetoda miareczkowa PN-EN ISO 9963-1:2001+Ap1:2004","categories":["water"],"row_index":96,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,2 – 20) mmol/l"}],"search_en":"Water Titrimetric method Range PN-EN ISO 9963-1:2001+Ap1:2004","technique_en":"Titrimetric method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,2 – 20) mmol/l"}],"search_zh":"水 滴定法 范围 PN-EN ISO 9963-1:2001+Ap1:2004","technique_zh":"滴定法","test_object_zh":"水"},{"_id":"6a82cee5884ede9a1b2c2efe","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie wodorowęglanów (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie wodorowęglanów (z obliczeń)","reference":"PN-EN ISO 9963-1:2001+Ap1:2004","norm_bases":["PN-EN ISO 9963-1:2001+Ap1:2004"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie wodorowęglanów (z obliczeń) PN-EN ISO 9963-1:2001+Ap1:2004 Woda Stezenie wodoroweglanow (z obliczen) PN-EN ISO 9963-1:2001+Ap1:2004","categories":["water"],"row_index":97,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Bicarbonate concentration (calculated)","search_en":"Water Bicarbonate concentration (calculated) PN-EN ISO 9963-1:2001+Ap1:2004","test_object_en":"Water","search_zh":"水 碳酸氢盐浓度（由计算得出） PN-EN ISO 9963-1:2001+Ap1:2004","test_object_zh":"水","methodology_zh":"碳酸氢盐浓度（由计算得出）"},{"_id":"6a82cee5884ede9a1b2c2eff","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Woda","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","parameters":[{"name":"Zakres","range":"(5 – 500) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (5 – 500) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (5 – 500) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres (5 – 500) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":98,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total content of calcium and magnesium (total hardness)","parameters_en":[{"name":"Range","range":"(5 – 500) mg/l CaCO3"}],"search_en":"Water Total content of calcium and magnesium (total hardness) Titrimetric method Range PN-ISO 6059:1999","technique_en":"Titrimetric method","test_object_en":"Water","methodology_zh":"钙与镁总量（总硬度）","parameters_zh":[{"name":"范围","range":"(5 – 500) mg/l CaCO3"}],"search_zh":"水 钙与镁总量（总硬度） 滴定法 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水"},{"_id":"6a82cee5884ede9a1b2c2f00","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Woda i ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"(2,0 – 12,0)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres (2,0 – 12,0)\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda i ścieki pH\nZakres (2,0 – 12,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda i scieki pH\nZakres (2,0 – 12,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":99,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"(2,0 – 12,0)"}],"search_en":"Water and wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water and wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"(2,0 – 12,0)"}],"search_zh":"水与废水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水与废水"},{"_id":"6a82cee5884ede9a1b2c2f01","lab_id":"69ad52a3de79e566650fb64e","country":"PL","accr_number":"AB 1226","accr_body":"PCA","test_object":"Woda i ścieki","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(10 – 12880) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (10 – 12880) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Laboratorium Badawcze EHS-LAB","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda i ścieki Przewodność elektryczna właściwa\nZakres (10 – 12880) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda i scieki Przewodnosc elektryczna wlasciwa\nZakres (10 – 12880) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":100,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(10 – 12880) μS/cm"}],"search_en":"Water and wastewater Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water and wastewater","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(10 – 12880) μS/cm"}],"search_zh":"水与废水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水与废水"}],"has_pdf":true}