🇵🇱 PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o. PL

PCA AB 1189 • Mińsk Mazowiecki, Poland • 56 methods

Water & wastewaterMicrobiology

PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o. is a laboratory accredited by PCA under number AB 1189 (Mińsk Mazowiecki, Poland). Its accreditation scope covers 56 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water, Water intended for human consumption, Wastewater, Water intended for human consumption, Water, Wastewater. Most frequently used techniques: Spectrophotometric method, Titrimetric method, Gravimetric method.

At a glance

  • Accreditation number: PCA AB 1189
  • Methods in scope: 56
  • Types of test objects: 8
  • Techniques used: 13
  • City: Mińsk Mazowiecki, Poland
Accreditation number
AB 1189
Accreditation body
PCA
Address
ul. Józefa Mireckiego 20, 05-300 Mińsk Mazowiecki, LABORATORIUM, ul. Aureliusza Chróścielewskiego 1B
City
Mińsk Mazowiecki, Poland

What this laboratory tests (8)

Analytical techniques used (13)

Laboratory sections (3)

Laboratory locations

Certificate information

Issue date
16.04.2026
Issue no.
25

Accreditation scope — test methods (56)

No. Test object Methodology / Parameters Technique Reference document
Wastewater Laboratory
1 Wastewater Ammonium nitrogen concentration
Range (1,0 – 150) mg/l
Titrimetric method PN-ISO 5664:2002
2 Wastewater Nitrate nitrogen concentration
Range (0,14 – 20) mg/l
Spectrophotometric method PN-82/C-04576/08
3 Wastewater Nitrite nitrogen concentration
Range (0,025 – 10) mg/l
Spectrophotometric method PN-EN 26777:1999
4 Wastewater Kjeldahl nitrogen concentration
Range (1,0 – 100) mg/l
Titrimetric method PN-EN 25663:2001
5 Wastewater Total nitrogen concentration (calculated) PB-13 wydanie III z dnia 17.07.2019 r.
6 Wastewater Biochemical oxygen demand
BOD5 Range (1,0 – 6000) mg/l O2
Titrimetric method PN-EN ISO 5815-1:2019-12
7 Wastewater Chemical oxygen demand
COD Range (30 – 10000) mg/l O2
Titrimetric method PB-19 wydanie III z dnia 17.07.2019 r.
8 Wastewater Chemical oxygen demand
COD Range (30 – 15000) mg/l O2
Titrimetric method PN-ISO 6060:2006
9 Wastewater Chemical oxygen demand
COD Range (20,0 – 20000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
10 Wastewater Chloride concentration
Range (5,0 – 1000) mg/l
Titrimetric method PN-ISO 9297:1994
11 Wastewater Sulfate concentration
Range (10,0 – 1000) mg/l
Gravimetric method PN-ISO 9280:2002
12 Wastewater Sampling for chemical and physical testing Manual method; Automatic method PN-ISO 5667-10:2021-11
13 Water Sampling for chemical and physical testing PN-EN ISO 5667-6:2016-12 + A11:2020-10 z wyłączeniem pkt 7.5, 7.6, 8.2
14 Water, Wastewater pH
Range 4,0 – 11,0
Potentiometric method PN-EN ISO 10523:2012
15 Water, Wastewater Total suspended solids (TSS)
Range (2,0 – 1000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
16 Water, Wastewater Biochemical oxygen demand
BOD5 Range (0,5 – 6) mg/l O2
Titrimetric method PN-EN 1899-2:2002
17 Water, Wastewater Total phosphorus concentration
Range (0,20 – 44,0) mg/l
Spectrophotometric method PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 p.7
18 Water, Wastewater Iron concentration
Range (0,30 – 20,0) mg/l
Spectrophotometric method PN-ISO 6332:2001 + Ap1:2016-06
19 Water, Wastewater Total nitrogen concentration (total)
Range (1,5 – 300) mg/l
Spectrophotometric method PB-21 wydanie III z dnia 17.07.2019 r. | na podstawie testu kuwetowego MERCK 1.00613.0001
20 Sewage sludge pH
Range 4,0 – 13,0
Potentiometric method PN-EN ISO 10390:2022-09
21 Sewage sludge Dry matter
Range (1,0 – 65) %
Gravimetric method PN-EN 15934:2013-02 metoda A
22 Sewage sludge Loss on ignition
Range (10,0 – 90,0) % s.m.
Gravimetric method PN-EN ISO 15935:2022-01
23 Sewage sludge Mineral substances (calculated) PN-EN ISO 15935:2022-01
24 Plant cultivation aids: - soil improvers pH
Range 6,0 – 13,0
Potentiometric method PN-EN ISO 10390:2022-09
25 Plant cultivation aids: - soil improvers Dry matter
Range (20,0 – 65) %
Gravimetric method PN-EN 15934:2013-02 metoda A
26 Plant cultivation aids: - soil improvers Loss on ignition
Range (10,0 – 55,0) % s.m.
Gravimetric method PN-EN ISO 15935:2022-01
27 Plant cultivation aids: - soil improvers Mineral substances (calculated) PN-EN ISO 15935:2022-01
28 Sewage sludge, Plant growth aids: - soil improvers Sampling for chemical and physical, microbiological and parasitological testing PN-EN ISO 5667-13:2011 z wyłączeniem pkt 6.3.3, 6.3.4, 6.3.5, 6.3.7, 6.3.8
29 Sewage sludge, Plant growth aids: - soil improvers Count of viable parasite eggs
intestinal ATT (Ascaris spp., Trichuris spp., Toxocara spp.) Range od 1 jaja/ kg s.m.
Microscopic method PN-Z-19005:2018-10
30 Sewage sludge, Plant growth aids: - soil improvers Presence of Salmonella spp. in 100 g Culture method with biochemical and serological confirmation PB-27 wyd. II z dnia 07.09.2023 r.
Water Chemistry Laboratory
31 Water Chemical oxygen demand
COD Range (3,0 – 40) mg/l
Spectrophotometric method PN-ISO 15705:2005
32 Water intended for human consumption Free chlorine concentration
Range (0,03 – 1,8) mg/l
Photometric method PB-26 wydanie I z dnia 31.05.2022 r. | na podstawie testu 7-20/936220/Macherey-Nagel
33 Water, Water intended for human consumption Chloride concentration
Range (5,0 – 100) mg/l
Spectrophotometric method PB-07 wydanie IV z dnia 17.07.2019 r. | na podstawie testu HACH 23198-00
34 Water, Water intended for human consumption Ammonium ion concentration
Range (0,020 – 5,0) mg/l
Spectrophotometric method PB-05 wydanie IV z dnia 17.07.2019 r. | na podstawie testu HACH 22437-00
35 Water, Water intended for human consumption Manganese concentration
Range (0,010 – 0,700) mg/l
Spectrophotometric method PB-01 wydanie V z dnia 17.07.2019 r. | na podstawie testu HACH 22433-00
36 Water, Water intended for human consumption pH
Range 4,0 – 10,0
Potentiometric method PN-EN ISO 10523:2012
37 Water, Water intended for human consumption Total content of calcium and magnesium (total hardness)
Range (0,05 – 10) mmol/l Range (5,0 – 1000) mg/l CaCO3
Titrimetric method PN-IS0 6059:1999
38 Water, Water intended for human consumption Sulfate concentration
Range (10 – 100) mg/l
Spectrophotometric method PB-08 wydanie IV z dnia 17.07.2019 r. | na podstawie testu HACH 12065-99
39 Water, Water intended for human consumption Total iron concentration
Range (0,010 – 5,0) mg/l
Spectrophotometric method PB-02 wydanie V z dnia 17.07.2019 r. | na podstawie testu HACH 854-99
40 Water, Water intended for human consumption Turbidity
Range (0,10 – 40) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
41 Water, Water intended for human consumption Nitrate concentration
Range (3,0 – 50) mg/l
Spectrophotometric method PB-03 wydanie IV z dnia 17.07.2019 r. | na podstawie testu HACH 21061-69
42 Water, Water intended for human consumption Permanganate index
Range (0,50 – 10,0) mg/lO2
Titrimetric method PN-EN ISO 8467:2001
43 Water, Water intended for human consumption Nitrite concentration
Range (0,020 – 0,700) mg/l
Spectrophotometric method PB-04 wydanie IV z dnia 17.07.2019r. | na podstawie testu HACH 21071-69
44 Water, Water intended for human consumption Electrical conductivity
Range (25 – 1000) μS/cm
Conductometric method PN-EN 27888:1999
45 Water, Water intended for human consumption Colour
Range (3 – 70) mg/l Pt
Spectrophotometric method PN-EN ISO 7887:2012 + Ap1:2015-06 Metoda C
46 Water intended for human consumption Sampling for chemical and physical testing (including sensory testing) PN-ISO 5667-5:2017-10
47 Water intended for human consumption Taste threshold number TFN
Range 1 TFN
Simplified method, paired, non-forced choice PN-EN 1622:2006
48 Water intended for human consumption Odour threshold number TON
Range 1 TON
Simplified method, paired, non-forced choice PN-EN 1622:2006
Water Microbiology Laboratory
49 Water intended for human consumption Total count of microorganisms at a temperature of 22°C ± 2°C Plate method (pour plate) PN-EN ISO 6222:2004
50 Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
51 Water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
52 Water intended for human consumption Enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
53 Water intended for human consumption Total count of microorganisms at a temperature of 36°C ± 2°C Plate method (pour plate) PN-EN ISO 6222:2004
54 Water intended for human consumption Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009
55 Water intended for human consumption Count of bacteria of the genus Legionella, Matrix A, Procedure 5 (BCYE medium), Procedure 7 (GVPC medium), Matrix B, Procedure 7 (GVPC medium) Membrane filtration method PN-EN ISO 11731:2017-08 +A1:2019-12
56 Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007

Reference standards (55)

PB-01 wydanie V z dnia 17.07.2019 r.
PB-02 wydanie V z dnia 17.07.2019 r.
PB-03 wydanie IV z dnia 17.07.2019 r.
PB-04 wydanie IV z dnia 17.07.2019r.
PB-05 wydanie IV z dnia 17.07.2019 r.
PB-07 wydanie IV z dnia 17.07.2019 r.
PB-08 wydanie IV z dnia 17.07.2019 r.
PB-13 wydanie III z dnia 17.07.2019 r.
PB-19 wydanie III z dnia 17.07.2019 r.
PB-21 wydanie III z dnia 17.07.2019 r.
PB-26 wydanie I z dnia 31.05.2022 r.
PB-27 wyd. II z dnia 07.09.2023 r.
PN-82/C-04576/08
PN-EN 15934:2013-02 metoda A
PN-EN 1622:2006
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10390:2022-09
PN-EN ISO 10523:2012
PN-EN ISO 11731:2017-08 +A1:2019-12
PN-EN ISO 15935:2022-01
PN-EN ISO 16266:2009
PN-EN ISO 19458:2007
PN-EN ISO 5667-13:2011 z wyłączeniem pkt 6.3.3, 6.3.4, 6.3.5, 6.3.7, 6.3.8
PN-EN ISO 5667-6:2016-12 + A11:2020-10 z wyłączeniem pkt 7.5, 7.6, 8.2
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 p.7
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 + Ap1:2015-06 Metoda C
PN-EN ISO 7899-2:2004
PN-EN ISO 8467:2001
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-IS0 6059:1999
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10
PN-ISO 6060:2006
PN-ISO 6332:2001 + Ap1:2016-06
PN-ISO 9280:2002
PN-ISO 9297:1994
PN-Z-19005:2018-10
na podstawie testu 7-20/936220/Macherey-Nagel
na podstawie testu HACH 12065-99
na podstawie testu HACH 21061-69
na podstawie testu HACH 21071-69
na podstawie testu HACH 22433-00
na podstawie testu HACH 22437-00
na podstawie testu HACH 23198-00
na podstawie testu HACH 854-99
na podstawie testu kuwetowego MERCK 1.00613.0001

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%201189