🇵🇱 PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o. PL

PCA AB 1189 • Mińsk Mazowiecki, Poland • 56 methods

Water & wastewaterMicrobiology

PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o. is a laboratory accredited by PCA under number AB 1189 (Mińsk Mazowiecki, Poland). Its accreditation scope covers 56 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water, Water intended for human consumption, Wastewater, Water intended for human consumption, Water, Wastewater. Most frequently used techniques: Spectrophotometric method, Titrimetric method, Gravimetric method.

At a glance

  • Accreditation number: PCA AB 1189
  • Methods in scope: 56
  • Types of test objects: 8
  • Techniques used: 13
  • City: Mińsk Mazowiecki, Poland
Accreditation number
AB 1189
Accreditation body
PCA
Address
ul. Józefa Mireckiego 20, 05-300 Mińsk Mazowiecki, LABORATORIUM, ul. Aureliusza Chróścielewskiego 1B
City
Mińsk Mazowiecki, Poland

What this laboratory tests (8)

Analytical techniques used (13)

Laboratory sections (3)

Laboratory locations

Accreditation scope — test methods (56)

No. Test object Methodology / Parameters Technique Reference document
Wastewater Laboratory
1 Wastewater Ammonium nitrogen concentration
Range (1,0 – 150) mg/l
Titrimetric method PN-ISO 5664:2002
2 Wastewater Nitrate nitrogen concentration
Range (0,14 – 20) mg/l
Spectrophotometric method PN-82/C-04576/08
3 Wastewater Nitrite nitrogen concentration
Range (0,025 – 10) mg/l
Spectrophotometric method PN-EN 26777:1999
4 Wastewater Kjeldahl nitrogen concentration
Range (1,0 – 100) mg/l
Titrimetric method PN-EN 25663:2001
5 Wastewater Total nitrogen concentration (calculated) PB-13 wydanie III z dnia 17.07.2019 r.
6 Wastewater Biochemical oxygen demand
BOD5 Range (1,0 – 6000) mg/l O2
Titrimetric method PN-EN ISO 5815-1:2019-12
7 Wastewater Chemical oxygen demand
COD Range (30 – 10000) mg/l O2
Titrimetric method PB-19 wydanie III z dnia 17.07.2019 r.
8 Wastewater Chemical oxygen demand
COD Range (30 – 15000) mg/l O2
Titrimetric method PN-ISO 6060:2006
9 Wastewater Chemical oxygen demand
COD Range (20,0 – 20000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
10 Wastewater Chloride concentration
Range (5,0 – 1000) mg/l
Titrimetric method PN-ISO 9297:1994
11 Wastewater Sulfate concentration
Range (10,0 – 1000) mg/l
Gravimetric method PN-ISO 9280:2002
12 Wastewater Sampling for chemical and physical testing Manual method; Automatic method PN-ISO 5667-10:2021-11
13 Water Sampling for chemical and physical testing PN-EN ISO 5667-6:2016-12 + A11:2020-10 z wyłączeniem pkt 7.5, 7.6, 8.2
14 Water, Wastewater pH
Range 4,0 – 11,0
Potentiometric method PN-EN ISO 10523:2012
15 Water, Wastewater Total suspended solids (TSS)
Range (2,0 – 1000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
16 Water, Wastewater Biochemical oxygen demand
BOD5 Range (0,5 – 6) mg/l O2
Titrimetric method PN-EN 1899-2:2002
17 Water, Wastewater Total phosphorus concentration
Range (0,20 – 44,0) mg/l
Spectrophotometric method PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 p.7
18 Water, Wastewater Iron concentration
Range (0,30 – 20,0) mg/l
Spectrophotometric method PN-ISO 6332:2001 + Ap1:2016-06
19 Water, Wastewater Total nitrogen concentration (total)
Range (1,5 – 300) mg/l
Spectrophotometric method PB-21 wydanie III z dnia 17.07.2019 r. | na podstawie testu kuwetowego MERCK 1.00613.0001
20 Sewage sludge pH
Range 4,0 – 13,0
Potentiometric method PN-EN ISO 10390:2022-09
21 Sewage sludge Dry matter
Range (1,0 – 65) %
Gravimetric method PN-EN 15934:2013-02 metoda A
22 Sewage sludge Loss on ignition
Range (10,0 – 90,0) % s.m.
Gravimetric method PN-EN ISO 15935:2022-01
23 Sewage sludge Mineral substances (calculated) PN-EN ISO 15935:2022-01
24 Plant cultivation aids: - soil improvers pH
Range 6,0 – 13,0
Potentiometric method PN-EN ISO 10390:2022-09
25 Plant cultivation aids: - soil improvers Dry matter
Range (20,0 – 65) %
Gravimetric method PN-EN 15934:2013-02 metoda A
26 Plant cultivation aids: - soil improvers Loss on ignition
Range (10,0 – 55,0) % s.m.
Gravimetric method PN-EN ISO 15935:2022-01
27 Plant cultivation aids: - soil improvers Mineral substances (calculated) PN-EN ISO 15935:2022-01
28 Sewage sludge, Plant growth aids: - soil improvers Sampling for chemical and physical, microbiological and parasitological testing PN-EN ISO 5667-13:2011 z wyłączeniem pkt 6.3.3, 6.3.4, 6.3.5, 6.3.7, 6.3.8
29 Sewage sludge, Plant growth aids: - soil improvers Count of viable parasite eggs
intestinal ATT (Ascaris spp., Trichuris spp., Toxocara spp.) Range od 1 jaja/ kg s.m.
Microscopic method PN-Z-19005:2018-10
30 Sewage sludge, Plant growth aids: - soil improvers Presence of Salmonella spp. in 100 g Culture method with biochemical and serological confirmation PB-27 wyd. II z dnia 07.09.2023 r.
Water Chemistry Laboratory
31 Water Chemical oxygen demand
COD Range (3,0 – 40) mg/l
Spectrophotometric method PN-ISO 15705:2005
32 Water intended for human consumption Free chlorine concentration
Range (0,03 – 1,8) mg/l
Photometric method PB-26 wydanie I z dnia 31.05.2022 r. | na podstawie testu 7-20/936220/Macherey-Nagel
33 Water, Water intended for human consumption Chloride concentration
Range (5,0 – 100) mg/l
Spectrophotometric method PB-07 wydanie IV z dnia 17.07.2019 r. | na podstawie testu HACH 23198-00
34 Water, Water intended for human consumption Ammonium ion concentration
Range (0,020 – 5,0) mg/l
Spectrophotometric method PB-05 wydanie IV z dnia 17.07.2019 r. | na podstawie testu HACH 22437-00
35 Water, Water intended for human consumption Manganese concentration
Range (0,010 – 0,700) mg/l
Spectrophotometric method PB-01 wydanie V z dnia 17.07.2019 r. | na podstawie testu HACH 22433-00
36 Water, Water intended for human consumption pH
Range 4,0 – 10,0
Potentiometric method PN-EN ISO 10523:2012
37 Water, Water intended for human consumption Total content of calcium and magnesium (total hardness)
Range (0,05 – 10) mmol/l Range (5,0 – 1000) mg/l CaCO3
Titrimetric method PN-IS0 6059:1999
38 Water, Water intended for human consumption Sulfate concentration
Range (10 – 100) mg/l
Spectrophotometric method PB-08 wydanie IV z dnia 17.07.2019 r. | na podstawie testu HACH 12065-99
39 Water, Water intended for human consumption Total iron concentration
Range (0,010 – 5,0) mg/l
Spectrophotometric method PB-02 wydanie V z dnia 17.07.2019 r. | na podstawie testu HACH 854-99
40 Water, Water intended for human consumption Turbidity
Range (0,10 – 40) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
41 Water, Water intended for human consumption Nitrate concentration
Range (3,0 – 50) mg/l
Spectrophotometric method PB-03 wydanie IV z dnia 17.07.2019 r. | na podstawie testu HACH 21061-69
42 Water, Water intended for human consumption Permanganate index
Range (0,50 – 10,0) mg/lO2
Titrimetric method PN-EN ISO 8467:2001
43 Water, Water intended for human consumption Nitrite concentration
Range (0,020 – 0,700) mg/l
Spectrophotometric method PB-04 wydanie IV z dnia 17.07.2019r. | na podstawie testu HACH 21071-69
44 Water, Water intended for human consumption Electrical conductivity
Range (25 – 1000) μS/cm
Conductometric method PN-EN 27888:1999
45 Water, Water intended for human consumption Colour
Range (3 – 70) mg/l Pt
Spectrophotometric method PN-EN ISO 7887:2012 + Ap1:2015-06 Metoda C
46 Water intended for human consumption Sampling for chemical and physical testing (including sensory testing) PN-ISO 5667-5:2017-10
47 Water intended for human consumption Taste threshold number TFN
Range 1 TFN
Simplified method, paired, non-forced choice PN-EN 1622:2006
48 Water intended for human consumption Odour threshold number TON
Range 1 TON
Simplified method, paired, non-forced choice PN-EN 1622:2006
Water Microbiology Laboratory
49 Water intended for human consumption Total count of microorganisms at a temperature of 22°C ± 2°C Plate method (pour plate) PN-EN ISO 6222:2004
50 Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
51 Water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
52 Water intended for human consumption Enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
53 Water intended for human consumption Total count of microorganisms at a temperature of 36°C ± 2°C Plate method (pour plate) PN-EN ISO 6222:2004
54 Water intended for human consumption Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009
55 Water intended for human consumption Count of bacteria of the genus Legionella, Matrix A, Procedure 5 (BCYE medium), Procedure 7 (GVPC medium), Matrix B, Procedure 7 (GVPC medium) Membrane filtration method PN-EN ISO 11731:2017-08 +A1:2019-12
56 Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007

Reference standards (55)

PB-01 wydanie V z dnia 17.07.2019 r.
PB-02 wydanie V z dnia 17.07.2019 r.
PB-03 wydanie IV z dnia 17.07.2019 r.
PB-04 wydanie IV z dnia 17.07.2019r.
PB-05 wydanie IV z dnia 17.07.2019 r.
PB-07 wydanie IV z dnia 17.07.2019 r.
PB-08 wydanie IV z dnia 17.07.2019 r.
PB-13 wydanie III z dnia 17.07.2019 r.
PB-19 wydanie III z dnia 17.07.2019 r.
PB-21 wydanie III z dnia 17.07.2019 r.
PB-26 wydanie I z dnia 31.05.2022 r.
PB-27 wyd. II z dnia 07.09.2023 r.
PN-82/C-04576/08
PN-EN 15934:2013-02 metoda A
PN-EN 1622:2006
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10390:2022-09
PN-EN ISO 10523:2012
PN-EN ISO 11731:2017-08 +A1:2019-12
PN-EN ISO 15935:2022-01
PN-EN ISO 16266:2009
PN-EN ISO 19458:2007
PN-EN ISO 5667-13:2011 z wyłączeniem pkt 6.3.3, 6.3.4, 6.3.5, 6.3.7, 6.3.8
PN-EN ISO 5667-6:2016-12 + A11:2020-10 z wyłączeniem pkt 7.5, 7.6, 8.2
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 p.7
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 + Ap1:2015-06 Metoda C
PN-EN ISO 7899-2:2004
PN-EN ISO 8467:2001
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-IS0 6059:1999
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10
PN-ISO 6060:2006
PN-ISO 6332:2001 + Ap1:2016-06
PN-ISO 9280:2002
PN-ISO 9297:1994
PN-Z-19005:2018-10
na podstawie testu 7-20/936220/Macherey-Nagel
na podstawie testu HACH 12065-99
na podstawie testu HACH 21061-69
na podstawie testu HACH 21071-69
na podstawie testu HACH 22433-00
na podstawie testu HACH 22437-00
na podstawie testu HACH 23198-00
na podstawie testu HACH 854-99
na podstawie testu kuwetowego MERCK 1.00613.0001