🇵🇱 ,,WODOCIĄGI PŁOCKIE” Sp. z o.o. PL
Water & wastewaterMicrobiology
,,WODOCIĄGI PŁOCKIE” Sp. z o.o. is a laboratory accredited by PCA under number AB 1188 (Płock, Poland). Its accreditation scope covers 80 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water, water intended for human consumption, Wastewater, Water, Sewage sludge. Most frequently used techniques: Gravimetric method, Spectrophotometric method, Titrimetric method.
At a glance
- Accreditation number: PCA AB 1188
- Methods in scope: 80
- Types of test objects: 9
- Techniques used: 20
- City: Płock, Poland
- Accreditation number
- AB 1188
- Accreditation body
- PCA
- Address
- ul. Harcerza Antolka Gradowskiego 11, 09-402 Płock, LABORATORIUM, ul. Górna 56 B, 09-402 Płock
- City
- Płock, Poland
What this laboratory tests (9)
- Water, water intended for human consumption — 22 methods
- Wastewater — 14 methods
- Water — 12 methods
- Sewage sludge — 10 methods
- Activated carbons — 8 methods
- Water, wastewater — 6 methods
- Odpady O) kod: 19 08 01, 19 08 02, 19 08 05, 19 12 09, 20 03 06 — 3 methods
- Water, water intended for human consumption, wastewater — 3 methods
- Water intended for human consumption — 2 methods
Analytical techniques used (20)
- Gravimetric method — 14 methods
- Spectrophotometric method — 11 methods
- Titrimetric method — 11 methods
- Ion chromatography with conductometric detection (IC-CD) — 6 methods
- Membrane filtration method — 5 methods
- Inductively coupled plasma optical emission spectrometry (ICP-OES) — 3 methods
- Optical method — 3 methods
- Potentiometric method — 3 methods
- Electrochemical method — 2 methods
- Full paired method, non-forced choice — 2 methods
- Metoda flotacji i mikroskopowa — 2 methods
- Plate method (pour plate) — 2 methods
- Simplified method, paired, non-forced choice — 2 methods
- Conductometric method — 1 method
- Culture method with biochemical confirmation — 1 method
- and 5 more
Laboratory locations
- Laboratorium — ul. Górna 56 B
Accreditation scope — test methods (80)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Laboratory | |||||
| 1 | Water intended for human consumption | Sampling for chemical and physical testing (including sensory testing) | PN-ISO 5667-5:2017-10 | ||
| 2 | Water intended for human consumption | Temperature Range (2,0 – 50,0) ºC |
PB/NW/19 wydanie 4 z dnia 02.12.2019 r. | ||
| 3 | Water, water intended for human consumption | Turbidity Range (0,20 – 50) NTU |
Nephelometric method | PN-EN ISO 7027-1:2016-09 rozdział 5.3 | |
| 4 | Water, water intended for human consumption | pH Range 4,0 – 12,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 5 | Water, water intended for human consumption | Concentration of highly volatile halogenated hydrocarbons Trichloromethane (chloroform) (2,0 – 50) µg/l Bromodichloromethane (2,0 – 50) µg/l Dibromochloromethane (2,0 – 50) µg/l Tribromometan (bromoform) (2,0 – 50) µg/l Tetrachloromethane (carbon tetrachloride) (1,0 – 10) µg/l 1,2-dichloroethane (1,0 – 10) µg/l Trichloroethene (trichloroethylene) (1,0 – 10) µg/l Tetrachloroethene (tetrachloroethylene) (1,0 – 10) µg/l Σ THM (calculated) |
Metoda chromatografii gazowej z detekcją wychwytu elektronów i analizą fazy nadpowierzchniowej (HS-GC-ECD) | PN-EN ISO 10301:2002 | |
| 6 | Water, water intended for human consumption | Anion concentrations Nitrates (0,10 – 60) mg/l Nitrites (0,10 – 1,0) mg/l Chlorides (0,10 – 300) mg/l Fluorides (0,10 – 5,0) mg/l Phosphates (0,10 – 5,0) mg/l Sulfates (0,50 – 300) mg/l |
Ion chromatography with conductometric detection (IC-CD) | PN-EN ISO 10304-1:2009+AC:2012 | |
| 7 | Water, water intended for human consumption | Permanganate index Range (0,50 – 20) mg/l O2 |
Titrimetric method | PN-EN ISO 8467:2001 | |
| 8 | Water, water intended for human consumption | Ammonium nitrogen concentration Range (0,04 – 1,00) mg/l |
Spectrophotometric method | PN-ISO 7150-1:2002 | |
| 9 | Water, water intended for human consumption | Colour Range (2 – 70) mg/l Pt |
Spectrophotometric method | PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06 | |
| 10 | Water, water intended for human consumption | Chlorate and chlorite concentration Range (0,010 – 2,0) mg/l |
Ion chromatography with conductometric detection (IC-CD) | PN-EN ISO 10304-4:2022-08 | |
| 11 | Water, water intended for human consumption | Cation concentrations Ammonium ion (0,10 – 5,0) mg/l Magnesium (1,0 – 150) mg/l Sodium (1,0 – 300) mg/l Potassium (1,0 – 50) mg/l Calcium (1,0 – 300) mg/l |
Ion chromatography with conductometric detection (IC-CD) | PN-EN ISO 14911:2002 | |
| 12 | Water, water intended for human consumption | Bromate concentration Range (5,0 – 20) µg/l |
Ion chromatography with conductometric detection (IC-CD) | PB/NW/38 wydanie 2 z dnia 02.12.2019 r. | |
| 13 | Water, water intended for human consumption | Total content of calcium and magnesium (total hardness) Range (5 – 500) mg/l CaCO3 |
Titrimetric method | PN-ISO 6059:1999 | |
| 14 | Water, water intended for human consumption | Element concentration Al (0,020 – 2,00) mg/l Mn (0,010 – 1,00) mg/l Mg (1,00 – 150) mg/l Ca (1,00 – 300) mg/l K (1,00 – 50,0) mg/l Na (1,00 – 300) mg/l |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | PN-EN ISO 11885:2009 | |
| 15 | Water, water intended for human consumption | Taste threshold number TFN Range 1 |
Simplified method, paired, non-forced choice | PN-EN 1622:2006 | |
| 16 | Water, water intended for human consumption | Taste threshold number TFN Range 1 – 4 |
Full paired method, non-forced choice | PN-EN 1622:2006 | |
| 17 | Water, water intended for human consumption | Odour threshold number TON Range 1 |
Simplified method, paired, non-forced choice | PN-EN 1622:2006 | |
| 18 | Water, water intended for human consumption | Odour threshold number TON Range 1 – 32 |
Full paired method, non-forced choice | PN-EN 1622:2006 | |
| 19 | Water | Absorbancja w UV Range 0,001 – 3,000 |
Spectrophotometric method | PB/NW/32 wydanie 2 z dnia 02.12.2019 r. | |
| 20 | Water | Kjeldahl nitrogen concentration Range (0,50 – 5,0) mg/l |
Spectrophotometric method | PN-EN 25663:2001 | |
| 21 | Water | Phenol index Range (0,002 – 0,010) mg/l |
Spectrophotometric method | PN-ISO 6439:1994 | |
| 22 | Water | Chemical oxygen demand COD-Cr Range (10 – 50) mg/l O2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 23 | Water | Całkowita substancja rozpuszczona (TDS) Range (20 – 2000) mg/l |
Gravimetric method | PN-EN 15216:2022-03 | |
| 24 | Water | Total alkalinity Range (20 – 500) mg/l CaCO3 Bicarbonate concentration (calculated) |
Titrimetric method | PN-EN ISO 9963-1:2001 p. 8.2 +Ap1:2004 | |
| 25 | Water | Total suspended solids (TSS) Range (2,0 – 1000) mg/l |
Gravimetric method | PN-EN 872:2007+Ap1:2007 | |
| 26 | Water | Bromide concentration Range (0,05 – 1,0) mg/l |
Ion chromatography with conductometric detection (IC-CD) | PN-EN ISO 10304-1:2009+AC:2012 | |
| 27 | Water | Biochemical oxygen demand - BOD5 Range (0,5 – 6,0) mg/l O2 |
Electrochemical method | PN-EN 1899-2:2002 | |
| 28 | Water | Biochemical oxygen demand - BOD5 Range (0,5 – 6,0) mg/l O2 |
Optical method | PN-EN 1899-2:2002 z wył. p. 7.2 | PB/NW/45 wydanie 1 z dnia 08.02.2019 r. | |
| 29 | Water, water intended for human consumption, wastewater | Stężenie ogólnego węgla organicznego (OWO) i rozpuszczonego węgla organicznego (RWO) Range (0,50 – 1000) mg/l |
Infrared spectrometry method (IR) | PN-EN 1484:1999 | |
| 30 | Water, water intended for human consumption, wastewater | Electrical conductivity Range (74,0 – 2770) µS/cm |
Conductometric method | PN-EN 27888:1999 | |
| 31 | Water, water intended for human consumption, wastewater | Iron concentration Range (0,010 – 15,0) mg/l |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | PN-EN ISO 11885:2009 | |
| 32 | Water, wastewater | Biochemical oxygen demand - BOD5 Range (1 – 6000) mg/l O2 |
Optical method | PN-EN ISO 5815-1:2019-12 | |
| 33 | Water, wastewater | Dissolved oxygen concentration Range (0,5 – 14,0) mg/l |
Electrochemical method | PN-EN ISO 5814:2013 | |
| 34 | Water, wastewater | Dissolved oxygen concentration Range (0,5 – 14,0) mg/l |
Optical method | PB/NW/45 wydanie 1 z dnia 08.02.2019 r. | |
| 35 | Water, wastewater | Total nitrogen concentration (calculated) | PB/NW/21 wydanie 4 z dnia 02.12.2019 r. | ||
| 36 | Water, wastewater | Chloride concentration Range (5 – 1200) mg/l |
Titrimetric method | PN-ISO 9297:1994 | |
| 37 | Water, wastewater | Mineral oil index Range (0,10 – 50) mg/l |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN ISO 9377-2:2003 | |
| 38 | Water, water intended for human consumption | Sampling for microbiological testing | PN-EN ISO 19458:2007 | ||
| 39 | Water, water intended for human consumption | Ogólna liczba mikroorganizmów w 22 ºC | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 40 | Water, water intended for human consumption | Coliform bacteria count | Membrane filtration method | PN-EN ISO 9308-1:2014-12 +A1:2017-04 | |
| 41 | Water, water intended for human consumption | Escherichia coli count | Membrane filtration method | PN-EN ISO 9308-1:2014-12 +A1:2017-04 | |
| 42 | Water, water intended for human consumption | Enterococci count | Membrane filtration method | PN-EN ISO 7899-2:2004 | |
| 43 | Water, water intended for human consumption | Liczba Clostridium perfringens łącznie z przetrwalnikami (sporami) | Membrane filtration method | PN-EN ISO 14189:2016-10 | |
| 44 | Water | Ogólna liczba mikroorganizmów w 36 ºC | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 45 | Water | Pseudomonas aeruginosa count | Membrane filtration method | PN-EN ISO 16266:2009 | |
| 46 | Wastewater | Total phosphorus concentration Range (0,033 – 48,9) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006 rozdział 8 +Ap1:2010+Ap2:2010 | |
| 47 | Wastewater | Phenol index Range (0,002 – 1,00) mg/l |
Spectrophotometric method | PN-ISO 6439:1994 | |
| 48 | Wastewater | Anion concentrations Nitrates (0,10 – 200) mg/l Nitrites (0,10 – 70) mg/l Chlorides (0,50 – 500) mg/l Phosphates (0,10 – 190) mg/l Sulfates (0,50 – 250) mg/l |
Ion chromatography with conductometric detection (IC-CD) | PN-EN ISO 10304-1:2009 +AC:2012 | |
| 49 | Wastewater | Kjeldahl nitrogen concentration Range (2,0 – 250) mg/l |
Titrimetric method | PN-EN 25663:2001 | |
| 50 | Wastewater | Chemical oxygen demand COD-Cr Range (10 – 10000) mg/l O2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 51 | Wastewater | pH Range 4,0 – 12,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 52 | Wastewater | Total alkalinity Range (20 – 1000) mg/l CaCO3 |
Titrimetric method | PN-EN ISO 9963-1:2001 p. 8.2 +Ap1:2004 | |
| 53 | Wastewater | Ammonium nitrogen concentration Range (1,0 – 250) mg/l |
Titrimetric method | PN-ISO 5664:2002 | |
| 54 | Wastewater | Concentration of substances extractable with petroleum ether Range (5,0 – 1000) mg/l |
Gravimetric method | PB/NW/5 wydanie 4 z dnia 02.12.2019 r. | |
| 55 | Wastewater | Non-ionic surfactant concentration Range (0,4 – 70) mg/l |
Spectrophotometric method | PN-ISO 7875-2:2002 | |
| 56 | Wastewater | Total suspended solids (TSS) Range (2,0 – 10 000) mg/l |
Gravimetric method | PN-EN 872:2007+Ap1:2007 | |
| 57 | Wastewater | Sampling for chemical and physical testing | Manual method; Automatic method | PN-ISO 5667-10:2021-11 | |
| 58 | Wastewater | Temperature Range (2,0 – 50,0) ºC |
PB/NW/19 wydanie 4 z dnia 02.12.2019 r. | ||
| 59 | Wastewater | Element concentration Ag (0,010 – 1,00) mg/l As (0,020 – 1,00) mg/l Cd (0,010 – 0,500) mg/l Cr (0,010 – 5,00) mg/l Cu (0,010 – 2,00) mg/l Ni (0,010 – 2,00) mg/l Pb (0,010 – 2,00) mg/l V (0,010 – 2,00) mg/l Zn (0,010 – 10,0) mg/l Pog (0,100 – 70,0) mg/l |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | PN-EN ISO 11885:2009 | |
| 60 | Sewage sludge | Ammonium nitrogen content Range (0,10 – 1,60) % |
Titrimetric method | PN-EN 14671:2007 | PN-ISO 5664:2002 | |
| 61 | Sewage sludge | Total nitrogen content Range (0,10 – 10,0) % |
Titrimetric method | PN-EN 13342:2002 | PN-EN 25663:2001 | |
| 62 | Sewage sludge | Strata przy prażeniu suchej masy osadu - substancje organiczne Range (1,0 – 99,0) % |
Gravimetric method | PN-EN 15935:2022-01 p. 7.3 | |
| 63 | Sewage sludge | Sucha pozostałość i zawartość wody – sucha masa Range (0,50 – 99,5) % |
Gravimetric method | PN-EN 15934:2013-02 Metoda A | |
| 64 | Sewage sludge | Total phosphorus content Range (0,10 – 5,00) % |
Spectrophotometric method | PN-EN 14672:2006 | PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010 | |
| 65 | Sewage sludge | pH in H2O Range 4,0 – 12,0 |
Potentiometric method | PN-EN ISO 10390:2022-09 | |
| 66 | Sewage sludge | Presence of bacteria of the genus Salmonella | Culture method with biochemical confirmation | PB/NW/M/11 wydanie 2 z dnia 02.12.2019 r. | |
| 67 | Sewage sludge | Obecność i liczba żywych jaj pasożytów jelitowych Ascaris sp., Trichuris sp., Toxocara sp.(ATT) Range od 1 w kg s.m. |
Metoda flotacji i mikroskopowa | PN-Z-19005:2018-10 | |
| 68 | Sewage sludge | Obecność i liczba żywych jaj pasożytów jelitowych Ascaris sp., Trichuris sp., Toxocara sp.(ATT) Range od 1 w kg s.m. |
Metoda flotacji i mikroskopowa | PB/NW/M/12 wydanie 3 z dnia 02.12.2019 r. | |
| 69 | Sewage sludge | Sampling for chemical, physical and microbiological testing | PN-EN ISO 5667-13:2011 | ||
| 70 | Odpady O) kod: 19 08 01, 19 08 02, 19 08 05, 19 12 09, 20 03 06 | Dry matter Range (1,0 – 99,0) % Regulated area: O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. |
Gravimetric method | PN-EN 15934:2013-02 Metoda A | |
| 71 | Odpady O) kod: 19 08 01, 19 08 02, 19 08 05, 19 12 09, 20 03 06 | Strata przy prażeniu (LOI) Range (1,0 – 99,0) % Regulated area: O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. |
Gravimetric method | PN-EN 15935:2022-01 p. 7.3 | |
| 72 | Odpady O) kod: 19 08 01, 19 08 02, 19 08 05, 19 12 09, 20 03 06 | Sampling for chemical and physical testing Regulated area: O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. |
PP/NW/1 wydanie 3 z dnia 02.12.2019 r. | ||
| 73 | Activated carbons | Liczba adsorpcji jodu Range (450 – 1500) mg/g |
Titrimetric method | PN-83/C-97555.04 | |
| 74 | Activated carbons | Bulk density Range (400 – 1000) g/dm3 |
Gravimetric method | PN-90/C-97554 p. 5.4.2 | |
| 75 | Activated carbons | Ash content Range (0,30 – 30,0) % |
Gravimetric method | PN-EN 12902:2005 p. 6.2 | |
| 76 | Activated carbons | Water content Range (1,5 – 60,0) % |
Gravimetric method | PN-EN 12902:2005 p. 6.5 | |
| 77 | Activated carbons | Water content Range (1,5 – 60,0) % |
Gravimetric method | PN-84/C-97555/09 p. 2 | |
| 78 | Activated carbons | Mechanical strength Range (1,0 – 100) % |
Gravimetric method | PN-EN 12915-1:2009 p. 8.2.4 | |
| 79 | Activated carbons | Sieve analysis Range (0,4 – 99,9) % |
Gravimetric method | PN-ISO 2591-1:2000 | |
| 80 | Activated carbons | Iodine value Range (600 – 1400) mg/g |
Titrimetric method | PN-EN 12902:2005 p. 6.10 | |
Reference standards (64)
PB/NW/19 wydanie 4 z dnia 02.12.2019 r.
PB/NW/21 wydanie 4 z dnia 02.12.2019 r.
PB/NW/32 wydanie 2 z dnia 02.12.2019 r.
PB/NW/38 wydanie 2 z dnia 02.12.2019 r.
PB/NW/45 wydanie 1 z dnia 08.02.2019 r.
PB/NW/5 wydanie 4 z dnia 02.12.2019 r.
PB/NW/M/11 wydanie 2 z dnia 02.12.2019 r.
PB/NW/M/12 wydanie 3 z dnia 02.12.2019 r.
PN-83/C-97555.04
PN-84/C-97555/09 p. 2
PN-90/C-97554 p. 5.4.2
PN-EN 12902:2005 p. 6.10
PN-EN 12902:2005 p. 6.2
PN-EN 12902:2005 p. 6.5
PN-EN 12915-1:2009 p. 8.2.4
PN-EN 13342:2002
PN-EN 14671:2007
PN-EN 14672:2006
PN-EN 1484:1999
PN-EN 15216:2022-03
PN-EN 15934:2013-02 Metoda A
PN-EN 15935:2022-01 p. 7.3
PN-EN 1622:2006
PN-EN 1899-2:2002
PN-EN 1899-2:2002 z wył. p. 7.2
PN-EN 25663:2001
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10301:2002
PN-EN ISO 10304-1:2009 +AC:2012
PN-EN ISO 10304-1:2009+AC:2012
PN-EN ISO 10304-4:2022-08
PN-EN ISO 10390:2022-09
PN-EN ISO 10523:2012
PN-EN ISO 11885:2009
PN-EN ISO 14189:2016-10
PN-EN ISO 14911:2002
PN-EN ISO 16266:2009
PN-EN ISO 19458:2007
PN-EN ISO 5667-13:2011
PN-EN ISO 5814:2013
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010
PN-EN ISO 6878:2006 rozdział 8 +Ap1:2010+Ap2:2010
PN-EN ISO 7027-1:2016-09 rozdział 5.3
PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06
PN-EN ISO 7899-2:2004
PN-EN ISO 8467:2001
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-EN ISO 9377-2:2003
PN-EN ISO 9963-1:2001 p. 8.2 +Ap1:2004
PN-ISO 15705:2005
PN-ISO 2591-1:2000
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10
PN-ISO 6059:1999
PN-ISO 6439:1994
PN-ISO 7150-1:2002
PN-ISO 7875-2:2002
PN-ISO 9297:1994
PN-Z-19005:2018-10
PP/NW/1 wydanie 3 z dnia 02.12.2019 r.