{"lab":{"_id":"69ad52a3de79e566650fb618","accr_number":"AB 1188","country":"PL","accr_body":"PCA","address":"ul. Harcerza Antolka Gradowskiego 11, 09-402 Płock, LABORATORIUM, ul. Górna 56 B, 09-402 Płock","categories":["water","microbiology"],"city":"Płock","imported_at":"2026-03-08T10:42:43.265Z","methods_count":80,"name":",,WODOCIĄGI PŁOCKIE” Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1188.pdf"],"scope_summary":"","search_text":",,wodociągi płockie” sp. z o.o. ul. harcerza antolka gradowskiego 11, 09-402 płock, laboratorium, ul. górna 56 b, 09-402 płock water other pharma electronics food microbiology automotive environment","status":"active","updated_at":"2026-03-08T14:50:22.336Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T08:46:37.528Z","email_confidence":"high","email_mx":true,"email_source":"https://wodociagi.pl/kontakt/","parse_date":"2026-08-17T08:46:37.528Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"B/32","pl":"Badania biologiczne osadów","en":"Biological tests of sediments"},{"codes":"C/28/P; C/29/P; C/30/P; C/32/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków, osadów","en":"Chemical tests and sampling of water, drinking water, sewage, sediments"},{"codes":"C/28","pl":"Badania chemiczne wody","en":"Chemical tests of water"},{"codes":"C/4","pl":"Badania chemiczne wyrobów chemicznych","en":"Chemical tests of chemical products"},{"codes":"K/28/P; K/29/P; K/32/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody, wody do spożycia przez ludzi, osadów","en":"Microbiological tests and sampling of water, drinking water, sediments"},{"codes":"N/28/P; N/29/P; N/30/P; N/32/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków, osadów, odpadów","en":"Tests of physical properties and sampling of water, drinking water, sewage, sediments, waste"},{"codes":"N/4","pl":"Badania właściwości fizycznych wyrobów chemicznych","en":"Tests of physical properties of chemical products"},{"codes":"Q/28/P; Q/29/P","pl":"Badania sensoryczne i pobieranie próbek wody, wody do spożycia przez ludzi","en":"Sensory tests and sampling of water, drinking water"}],"issue":{"no":"17","date":"07.05.2026"},"map_coord":[52.542416,19.702442],"map_geo":"nominatim-street","lab_locations":[{"name":"Laboratorium","address":"ul. Górna 56 B","city":"Płock","postal":"09-402"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/24b69c5a4dfdc55453dfb95b4f85b20f/AB%201188.pdf","has_en":true,"category_counts":{"water":71,"other":6,"microbiology":5,"environment":3,"petro":1},"category_scores":{"water":58.62,"other":0.42,"microbiology":0.29,"environment":0.1,"petro":0.01},"has_zh":true,"lab_locations_zh":[{"name":"实验室","address":"ul. Górna 56 B","city":"Płock","postal":"09-402"}]},"methods":[{"_id":"6a82ca6d884ede9a1b2c2d3d","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań chemicznych i fizycznych (w tym sensorycznych)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych (w tym sensorycznych)","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych (w tym sensorycznych) PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych (w tym sensorycznych) PN-ISO 5667-5:2017-10","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sampling for chemical and physical testing (including sensory testing)","search_en":"Water intended for human consumption Sampling for chemical and physical testing (including sensory testing) Laboratory PN-ISO 5667-5:2017-10","test_object_en":"Water intended for human consumption","lab_section_zh":"实验室","search_zh":"生活饮用水 化学和物理检测采样（含感官检测） 实验室 PN-ISO 5667-5:2017-10","test_object_zh":"生活饮用水","methodology_zh":"化学和物理检测采样（含感官检测）"},{"_id":"6a82ca6d884ede9a1b2c2d3e","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Temperatura","parameters":[{"name":"Zakres","range":"(2,0 – 50,0) ºC"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura\nZakres (2,0 – 50,0) ºC","reference":"PB/NW/19 wydanie 4 z dnia 02.12.2019 r.","norm_bases":["PB/NW/19 wydanie 4 z dnia 02.12.2019 r."],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Temperatura\nZakres (2,0 – 50,0) ºC PB/NW/19 wydanie 4 z dnia 02.12.2019 r. Woda do spozycia przez ludzi Temperatura\nZakres (2,0 – 50,0) ºC PB/NW/19 wydanie 4 z dnia 02.12.2019 r.","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Temperature","parameters_en":[{"name":"Range","range":"(2,0 – 50,0) ºC"}],"search_en":"Water intended for human consumption Temperature Laboratory Range PB/NW/19 wydanie 4 z dnia 02.12.2019 r.","test_object_en":"Water intended for human consumption","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(2,0 – 50,0) ºC"}],"search_zh":"生活饮用水 温度 实验室 范围 PB/NW/19 wydanie 4 z dnia 02.12.2019 r.","test_object_zh":"生活饮用水","methodology_zh":"温度"},{"_id":"6a82ca6d884ede9a1b2c2d3f","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,20 – 50) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,20 – 50) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09 rozdział 5.3","norm_bases":["PN-EN ISO 7027-1:2016-09 rozdział 5.3"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Mętność\nZakres (0,20 – 50) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 rozdział 5.3 Woda, woda do spozycia przez ludzi Metnosc\nZakres (0,20 – 50) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 rozdzial 5.3","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,20 – 50) NTU"}],"search_en":"Water, water intended for human consumption Turbidity Nephelometric method Laboratory Range PN-EN ISO 7027-1:2016-09 rozdział 5.3","technique_en":"Nephelometric method","test_object_en":"Water, water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,20 – 50) NTU"}],"search_zh":"水、生活饮用水 浊度 浊度法（散射法） 实验室 范围 PN-EN ISO 7027-1:2016-09 rozdział 5.3","technique_zh":"浊度法（散射法）","test_object_zh":"水、生活饮用水"},{"_id":"6a82ca6d884ede9a1b2c2d40","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi pH\nZakres 4,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, woda do spozycia przez ludzi pH\nZakres 4,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 12,0"}],"search_en":"Water, water intended for human consumption pH Potentiometric method Laboratory Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 12,0"}],"search_zh":"水、生活饮用水 pH 值 电位法 实验室 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、生活饮用水"},{"_id":"6a82ca6d884ede9a1b2c2d41","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie łatwo lotnych chlorowcowych pochodnych węglowodorów","parameters":[{"name":"Trichlorometan (chloroform)","range":"(2,0 – 50) µg/l"},{"name":"Bromodichlorometan","range":"(2,0 – 50) µg/l"},{"name":"Dibromochlorometan","range":"(2,0 – 50) µg/l"},{"name":"Tribromometan (bromoform)","range":"(2,0 – 50) µg/l"},{"name":"Tetrachlorometan (czterochlorek węgla)","range":"(1,0 – 10) µg/l"},{"name":"1,2-dichloroetan","range":"(1,0 – 10) µg/l"},{"name":"Trichloroeten (trichloroetylen)","range":"(1,0 – 10) µg/l"},{"name":"Tetrachloroeten (tetrachloroetylen)","range":"(1,0 – 10) µg/l"},{"name":"Σ THM (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją wychwytu elektronów i analizą fazy nadpowierzchniowej (HS-GC-ECD)","techniques":["Metoda chromatografii gazowej z detekcją wychwytu elektronów i analizą fazy nadpowierzchniowej (HS-GC-ECD)"],"computed":[],"activity":"Stężenie łatwo lotnych chlorowcowych pochodnych węglowodorów\nZakres:\nTrichlorometan (chloroform) (2,0 – 50) µg/l\nBromodichlorometan (2,0 – 50) µg/l\nDibromochlorometan (2,0 – 50) µg/l\nTribromometan (bromoform) (2,0 – 50) µg/l\nTetrachlorometan (czterochlorek węgla) (1,0 – 10) µg/l\n1,2-dichloroetan (1,0 – 10) µg/l\nTrichloroeten (trichloroetylen) (1,0 – 10) µg/l\nTetrachloroeten (tetrachloroetylen) (1,0 – 10) µg/l\nΣ THM (z obliczeń)\nMetoda chromatografii gazowej z detekcją wychwytu elektronów i analizą fazy nadpowierzchniowej (HS-GC-ECD)","reference":"PN-EN ISO 10301:2002","norm_bases":["PN-EN ISO 10301:2002"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie łatwo lotnych chlorowcowych pochodnych węglowodorów\nZakres:\nTrichlorometan (chloroform) (2,0 – 50) µg/l\nBromodichlorometan (2,0 – 50) µg/l\nDibromochlorometan (2,0 – 50) µg/l\nTribromometan (bromoform) (2,0 – 50) µg/l\nTetrachlorometan (czterochlorek węgla) (1,0 – 10) µg/l\n1,2-dichloroetan (1,0 – 10) µg/l\nTrichloroeten (trichloroetylen) (1,0 – 10) µg/l\nTetrachloroeten (tetrachloroetylen) (1,0 – 10) µg/l\nΣ THM (z obliczeń)\nMetoda chromatografii gazowej z detekcją wychwytu elektronów i analizą fazy nadpowierzchniowej (HS-GC-ECD) PN-EN ISO 10301:2002 Woda, woda do spozycia przez ludzi Stezenie latwo lotnych chlorowcowych pochodnych weglowodorow\nZakres:\nTrichlorometan (chloroform) (2,0 – 50) µg/l\nBromodichlorometan (2,0 – 50) µg/l\nDibromochlorometan (2,0 – 50) µg/l\nTribromometan (bromoform) (2,0 – 50) µg/l\nTetrachlorometan (czterochlorek wegla) (1,0 – 10) µg/l\n1,2-dichloroetan (1,0 – 10) µg/l\nTrichloroeten (trichloroetylen) (1,0 – 10) µg/l\nTetrachloroeten (tetrachloroetylen) (1,0 – 10) µg/l\nΣ THM (z obliczen)\nMetoda chromatografii gazowej z detekcja wychwytu elektronow i analiza fazy nadpowierzchniowej (HS-GC-ECD) PN-EN ISO 10301:2002","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Concentration of highly volatile halogenated hydrocarbons","parameters_en":[{"name":"Trichloromethane (chloroform)","range":"(2,0 – 50) µg/l"},{"name":"Bromodichloromethane","range":"(2,0 – 50) µg/l"},{"name":"Dibromochloromethane","range":"(2,0 – 50) µg/l"},{"name":"Tribromometan (bromoform)","range":"(2,0 – 50) µg/l"},{"name":"Tetrachloromethane (carbon tetrachloride)","range":"(1,0 – 10) µg/l"},{"name":"1,2-dichloroethane","range":"(1,0 – 10) µg/l"},{"name":"Trichloroethene (trichloroethylene)","range":"(1,0 – 10) µg/l"},{"name":"Tetrachloroethene (tetrachloroethylene)","range":"(1,0 – 10) µg/l"},{"name":"Σ THM (calculated)"}],"search_en":"Water, water intended for human consumption Concentration of highly volatile halogenated hydrocarbons Laboratory Trichloromethane (chloroform) Bromodichloromethane Dibromochloromethane Tetrachloromethane (carbon tetrachloride) 1,2-dichloroethane Trichloroethene (trichloroethylene) Tetrachloroethene (tetrachloroethylene) Σ THM (calculated) PN-EN ISO 10301:2002","test_object_en":"Water, water intended for human consumption","lab_section_zh":"实验室","search_zh":"水、生活饮用水 易挥发卤代烃浓度 实验室 一溴二氯甲烷 二溴一氯甲烷 1,2-二氯乙烷 PN-EN ISO 10301:2002","test_object_zh":"水、生活饮用水","parameters_zh":[{"name":"Trichlorometan (chloroform)","range":"(2,0 – 50) µg/l"},{"name":"一溴二氯甲烷","range":"(2,0 – 50) µg/l"},{"name":"二溴一氯甲烷","range":"(2,0 – 50) µg/l"},{"name":"Tribromometan (bromoform)","range":"(2,0 – 50) µg/l"},{"name":"Tetrachlorometan (czterochlorek węgla)","range":"(1,0 – 10) µg/l"},{"name":"1,2-二氯乙烷","range":"(1,0 – 10) µg/l"},{"name":"Trichloroeten (trichloroetylen)","range":"(1,0 – 10) µg/l"},{"name":"Tetrachloroeten (tetrachloroetylen)","range":"(1,0 – 10) µg/l"},{"name":"Σ THM (z obliczeń)"}],"methodology_zh":"易挥发卤代烃浓度"},{"_id":"6a82ca6d884ede9a1b2c2d42","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie anionów","parameters":[{"name":"Azotany","range":"(0,10 – 60) mg/l"},{"name":"Azotyny","range":"(0,10 – 1,0) mg/l"},{"name":"Chlorki","range":"(0,10 – 300) mg/l"},{"name":"Fluorki","range":"(0,10 – 5,0) mg/l"},{"name":"Fosforany","range":"(0,10 – 5,0) mg/l"},{"name":"Siarczany","range":"(0,50 – 300) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów\nZakres:\nAzotany (0,10 – 60) mg/l\nAzotyny (0,10 – 1,0) mg/l\nChlorki (0,10 – 300) mg/l\nFluorki (0,10 – 5,0) mg/l\nFosforany (0,10 – 5,0) mg/l\nSiarczany (0,50 – 300) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie anionów\nZakres:\nAzotany (0,10 – 60) mg/l\nAzotyny (0,10 – 1,0) mg/l\nChlorki (0,10 – 300) mg/l\nFluorki (0,10 – 5,0) mg/l\nFosforany (0,10 – 5,0) mg/l\nSiarczany (0,50 – 300) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda, woda do spozycia przez ludzi Stezenie anionow\nZakres:\nAzotany (0,10 – 60) mg/l\nAzotyny (0,10 – 1,0) mg/l\nChlorki (0,10 – 300) mg/l\nFluorki (0,10 – 5,0) mg/l\nFosforany (0,10 – 5,0) mg/l\nSiarczany (0,50 – 300) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Anion concentrations","parameters_en":[{"name":"Nitrates","range":"(0,10 – 60) mg/l"},{"name":"Nitrites","range":"(0,10 – 1,0) mg/l"},{"name":"Chlorides","range":"(0,10 – 300) mg/l"},{"name":"Fluorides","range":"(0,10 – 5,0) mg/l"},{"name":"Phosphates","range":"(0,10 – 5,0) mg/l"},{"name":"Sulfates","range":"(0,50 – 300) mg/l"}],"search_en":"Water, water intended for human consumption Anion concentrations Ion chromatography with conductometric detection (IC-CD) Laboratory Nitrates Nitrites Chlorides Fluorides Phosphates Sulfates PN-EN ISO 10304-1:2009+AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water, water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"阴离子浓度","parameters_zh":[{"name":"硝酸盐","range":"(0,10 – 60) mg/l"},{"name":"亚硝酸盐","range":"(0,10 – 1,0) mg/l"},{"name":"氯化物","range":"(0,10 – 300) mg/l"},{"name":"氟化物","range":"(0,10 – 5,0) mg/l"},{"name":"磷酸盐","range":"(0,10 – 5,0) mg/l"},{"name":"硫酸盐","range":"(0,50 – 300) mg/l"}],"search_zh":"水、生活饮用水 阴离子浓度 离子色谱-电导检测法（IC-CD） 实验室 硝酸盐 亚硝酸盐 氯化物 氟化物 磷酸盐 硫酸盐 PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、生活饮用水"},{"_id":"6a82ca6d884ede9a1b2c2d43","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Indeks nadmanganianowy","parameters":[{"name":"Zakres","range":"(0,50 – 20) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy\nZakres (0,50 – 20) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Indeks nadmanganianowy\nZakres (0,50 – 20) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda, woda do spozycia przez ludzi Indeks nadmanganianowy\nZakres (0,50 – 20) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Permanganate index","parameters_en":[{"name":"Range","range":"(0,50 – 20) mg/l O2"}],"search_en":"Water, water intended for human consumption Permanganate index Titrimetric method Laboratory Range PN-EN ISO 8467:2001","technique_en":"Titrimetric method","test_object_en":"Water, water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,50 – 20) mg/l O2"}],"search_zh":"水、生活饮用水 高锰酸盐指数 滴定法 实验室 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"水、生活饮用水"},{"_id":"6a82ca6d884ede9a1b2c2d44","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,04 – 1,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,04 – 1,00) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie azotu amonowego\nZakres (0,04 – 1,00) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, woda do spozycia przez ludzi Stezenie azotu amonowego\nZakres (0,04 – 1,00) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,04 – 1,00) mg/l"}],"search_en":"Water, water intended for human consumption Ammonium nitrogen concentration Spectrophotometric method Laboratory Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,04 – 1,00) mg/l"}],"search_zh":"水、生活饮用水 氨氮浓度 分光光度法 实验室 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a82ca6d884ede9a1b2c2d45","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(2 – 70) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa\nZakres (2 – 70) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06","norm_bases":["PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Barwa\nZakres (2 – 70) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06 Woda, woda do spozycia przez ludzi Barwa\nZakres (2 – 70) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(2 – 70) mg/l Pt"}],"search_en":"Water, water intended for human consumption Colour Spectrophotometric method Laboratory Range PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(2 – 70) mg/l Pt"}],"search_zh":"水、生活饮用水 色度 分光光度法 实验室 范围 PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a82ca6d884ede9a1b2c2d46","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie chloranów i chlorynów","parameters":[{"name":"Zakres","range":"(0,010 – 2,0) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie chloranów i chlorynów\nZakres (0,010 – 2,0) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-4:2022-08","norm_bases":["PN-EN ISO 10304-4:2022-08"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie chloranów i chlorynów\nZakres (0,010 – 2,0) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-4:2022-08 Woda, woda do spozycia przez ludzi Stezenie chloranow i chlorynow\nZakres (0,010 – 2,0) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-4:2022-08","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Chlorate and chlorite concentration","parameters_en":[{"name":"Range","range":"(0,010 – 2,0) mg/l"}],"search_en":"Water, water intended for human consumption Chlorate and chlorite concentration Ion chromatography with conductometric detection (IC-CD) Laboratory Range PN-EN ISO 10304-4:2022-08","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water, water intended for human consumption","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,010 – 2,0) mg/l"}],"search_zh":"水、生活饮用水 离子色谱-电导检测法（IC-CD） 实验室 范围 PN-EN ISO 10304-4:2022-08","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、生活饮用水"},{"_id":"6a82ca6d884ede9a1b2c2d47","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie kationów","parameters":[{"name":"Jon amonowy","range":"(0,10 – 5,0) mg/l"},{"name":"Magnez","range":"(1,0 – 150) mg/l"},{"name":"Sód","range":"(1,0 – 300) mg/l"},{"name":"Potas","range":"(1,0 – 50) mg/l"},{"name":"Wapń","range":"(1,0 – 300) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie kationów\nZakres:\nJon amonowy (0,10 – 5,0) mg/l\nMagnez (1,0 – 150) mg/l\nSód (1,0 – 300) mg/l\nPotas (1,0 – 50) mg/l\nWapń (1,0 – 300) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 14911:2002","norm_bases":["PN-EN ISO 14911:2002"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie kationów\nZakres:\nJon amonowy (0,10 – 5,0) mg/l\nMagnez (1,0 – 150) mg/l\nSód (1,0 – 300) mg/l\nPotas (1,0 – 50) mg/l\nWapń (1,0 – 300) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 14911:2002 Woda, woda do spozycia przez ludzi Stezenie kationow\nZakres:\nJon amonowy (0,10 – 5,0) mg/l\nMagnez (1,0 – 150) mg/l\nSod (1,0 – 300) mg/l\nPotas (1,0 – 50) mg/l\nWapn (1,0 – 300) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 14911:2002","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Cation concentrations","parameters_en":[{"name":"Ammonium ion","range":"(0,10 – 5,0) mg/l"},{"name":"Magnesium","range":"(1,0 – 150) mg/l"},{"name":"Sodium","range":"(1,0 – 300) mg/l"},{"name":"Potassium","range":"(1,0 – 50) mg/l"},{"name":"Calcium","range":"(1,0 – 300) mg/l"}],"search_en":"Water, water intended for human consumption Cation concentrations Ion chromatography with conductometric detection (IC-CD) Laboratory Ammonium ion Magnesium Sodium Potassium Calcium PN-EN ISO 14911:2002","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water, water intended for human consumption","lab_section_zh":"实验室","search_zh":"水、生活饮用水 阳离子浓度 离子色谱-电导检测法（IC-CD） 实验室 镁 钠 钾 钙 PN-EN ISO 14911:2002","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、生活饮用水","parameters_zh":[{"name":"Jon amonowy","range":"(0,10 – 5,0) mg/l"},{"name":"镁","range":"(1,0 – 150) mg/l"},{"name":"钠","range":"(1,0 – 300) mg/l"},{"name":"钾","range":"(1,0 – 50) mg/l"},{"name":"钙","range":"(1,0 – 300) mg/l"}],"methodology_zh":"阳离子浓度"},{"_id":"6a82ca6d884ede9a1b2c2d48","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie bromianów","parameters":[{"name":"Zakres","range":"(5,0 – 20) µg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie bromianów\nZakres (5,0 – 20) µg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PB/NW/38 wydanie 2 z dnia 02.12.2019 r.","norm_bases":["PB/NW/38 wydanie 2 z dnia 02.12.2019 r."],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie bromianów\nZakres (5,0 – 20) µg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PB/NW/38 wydanie 2 z dnia 02.12.2019 r. Woda, woda do spozycia przez ludzi Stezenie bromianow\nZakres (5,0 – 20) µg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PB/NW/38 wydanie 2 z dnia 02.12.2019 r.","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Bromate concentration","parameters_en":[{"name":"Range","range":"(5,0 – 20) µg/l"}],"search_en":"Water, water intended for human consumption Bromate concentration Ion chromatography with conductometric detection (IC-CD) Laboratory Range PB/NW/38 wydanie 2 z dnia 02.12.2019 r.","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water, water intended for human consumption","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(5,0 – 20) µg/l"}],"search_zh":"水、生活饮用水 溴酸盐浓度 离子色谱-电导检测法（IC-CD） 实验室 范围 PB/NW/38 wydanie 2 z dnia 02.12.2019 r.","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、生活饮用水","methodology_zh":"溴酸盐浓度"},{"_id":"6a82ca6d884ede9a1b2c2d49","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","parameters":[{"name":"Zakres","range":"(5 – 500) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (5 – 500) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (5 – 500) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda, woda do spozycia przez ludzi Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres (5 – 500) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total content of calcium and magnesium (total hardness)","parameters_en":[{"name":"Range","range":"(5 – 500) mg/l CaCO3"}],"search_en":"Water, water intended for human consumption Total content of calcium and magnesium (total hardness) Titrimetric method Laboratory Range PN-ISO 6059:1999","technique_en":"Titrimetric method","test_object_en":"Water, water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"钙与镁总量（总硬度）","parameters_zh":[{"name":"范围","range":"(5 – 500) mg/l CaCO3"}],"search_zh":"水、生活饮用水 钙与镁总量（总硬度） 滴定法 实验室 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水、生活饮用水"},{"_id":"6a82ca6d884ede9a1b2c2d4a","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie pierwiastków","parameters":[{"name":"Al","range":"(0,020 – 2,00) mg/l"},{"name":"Mn","range":"(0,010 – 1,00) mg/l"},{"name":"Mg","range":"(1,00 – 150) mg/l"},{"name":"Ca","range":"(1,00 – 300) mg/l"},{"name":"K","range":"(1,00 – 50,0) mg/l"},{"name":"Na","range":"(1,00 – 300) mg/l"}],"technique":"Metoda optycznej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda optycznej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie pierwiastków\nZakres:\nAl (0,020 – 2,00) mg/l\nMn (0,010 – 1,00) mg/l\nMg (1,00 – 150) mg/l\nCa (1,00 – 300) mg/l\nK (1,00 – 50,0) mg/l\nNa (1,00 – 300) mg/l\nMetoda optycznej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie pierwiastków\nZakres:\nAl (0,020 – 2,00) mg/l\nMn (0,010 – 1,00) mg/l\nMg (1,00 – 150) mg/l\nCa (1,00 – 300) mg/l\nK (1,00 – 50,0) mg/l\nNa (1,00 – 300) mg/l\nMetoda optycznej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Woda, woda do spozycia przez ludzi Stezenie pierwiastkow\nZakres:\nAl (0,020 – 2,00) mg/l\nMn (0,010 – 1,00) mg/l\nMg (1,00 – 150) mg/l\nCa (1,00 – 300) mg/l\nK (1,00 – 50,0) mg/l\nNa (1,00 – 300) mg/l\nMetoda optycznej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Element concentration","parameters_en":[{"name":"Al","range":"(0,020 – 2,00) mg/l"},{"name":"Mn","range":"(0,010 – 1,00) mg/l"},{"name":"Mg","range":"(1,00 – 150) mg/l"},{"name":"Ca","range":"(1,00 – 300) mg/l"},{"name":"K","range":"(1,00 – 50,0) mg/l"},{"name":"Na","range":"(1,00 – 300) mg/l"}],"search_en":"Water, water intended for human consumption Element concentration Inductively coupled plasma optical emission spectrometry (ICP-OES) Laboratory Al Mn Mg Ca K Na PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Water, water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"元素浓度","search_zh":"水、生活饮用水 元素浓度 电感耦合等离子体光学发射光谱法（ICP-OES） 实验室 Al Mn Mg Ca K Na PN-EN ISO 11885:2009","test_object_zh":"水、生活饮用水","parameters_zh":[{"name":"Al","range":"(0,020 – 2,00) mg/l"},{"name":"Mn","range":"(0,010 – 1,00) mg/l"},{"name":"Mg","range":"(1,00 – 150) mg/l"},{"name":"Ca","range":"(1,00 – 300) mg/l"},{"name":"K","range":"(1,00 – 50,0) mg/l"},{"name":"Na","range":"(1,00 – 300) mg/l"}],"technique_zh":"电感耦合等离子体光学发射光谱法（ICP-OES）"},{"_id":"6a82ca6d884ede9a1b2c2d4b","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Liczba progowa smaku TFN","parameters":[{"name":"Zakres","range":"1"}],"technique":"Metoda uproszczona, parzysta, wybór niewymuszony","techniques":["Metoda uproszczona, parzysta, wybór niewymuszony"],"computed":[],"activity":"Liczba progowa smaku TFN\nZakres 1\nMetoda uproszczona, parzysta, wybór niewymuszony","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Liczba progowa smaku TFN\nZakres 1\nMetoda uproszczona, parzysta, wybór niewymuszony PN-EN 1622:2006 Woda, woda do spozycia przez ludzi Liczba progowa smaku TFN\nZakres 1\nMetoda uproszczona, parzysta, wybor niewymuszony PN-EN 1622:2006","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Taste threshold number TFN","parameters_en":[{"name":"Range","range":"1"}],"search_en":"Water, water intended for human consumption Taste threshold number TFN Simplified method, paired, non-forced choice Laboratory Range PN-EN 1622:2006","technique_en":"Simplified method, paired, non-forced choice","test_object_en":"Water, water intended for human consumption","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"1"}],"search_zh":"水、生活饮用水 味阈值 TFN 简化法，成对，非强制选择 实验室 范围 PN-EN 1622:2006","test_object_zh":"水、生活饮用水","technique_zh":"简化法，成对，非强制选择","methodology_zh":"味阈值 TFN"},{"_id":"6a82ca6d884ede9a1b2c2d4c","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Liczba progowa smaku TFN","parameters":[{"name":"Zakres","range":"1 – 4"}],"technique":"Metoda pełna, parzysta, wybór niewymuszony","techniques":["Metoda pełna, parzysta, wybór niewymuszony"],"computed":[],"activity":"Liczba progowa smaku TFN\nZakres 1 – 4\nMetoda pełna, parzysta, wybór niewymuszony","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Liczba progowa smaku TFN\nZakres 1 – 4\nMetoda pełna, parzysta, wybór niewymuszony PN-EN 1622:2006 Woda, woda do spozycia przez ludzi Liczba progowa smaku TFN\nZakres 1 – 4\nMetoda pelna, parzysta, wybor niewymuszony PN-EN 1622:2006","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Taste threshold number TFN","parameters_en":[{"name":"Range","range":"1 – 4"}],"search_en":"Water, water intended for human consumption Taste threshold number TFN Full paired method, non-forced choice Laboratory Range PN-EN 1622:2006","technique_en":"Full paired method, non-forced choice","test_object_en":"Water, water intended for human consumption","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"1 – 4"}],"search_zh":"水、生活饮用水 味阈值 TFN 完全法、成对法、非强制选择 实验室 范围 PN-EN 1622:2006","test_object_zh":"水、生活饮用水","methodology_zh":"味阈值 TFN","technique_zh":"完全法、成对法、非强制选择"},{"_id":"6a82ca6d884ede9a1b2c2d4d","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Liczba progowa zapachu TON","parameters":[{"name":"Zakres","range":"1"}],"technique":"Metoda uproszczona, parzysta, wybór niewymuszony","techniques":["Metoda uproszczona, parzysta, wybór niewymuszony"],"computed":[],"activity":"Liczba progowa zapachu TON\nZakres 1\nMetoda uproszczona, parzysta, wybór niewymuszony","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Liczba progowa zapachu TON\nZakres 1\nMetoda uproszczona, parzysta, wybór niewymuszony PN-EN 1622:2006 Woda, woda do spozycia przez ludzi Liczba progowa zapachu TON\nZakres 1\nMetoda uproszczona, parzysta, wybor niewymuszony PN-EN 1622:2006","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Odour threshold number TON","parameters_en":[{"name":"Range","range":"1"}],"search_en":"Water, water intended for human consumption Odour threshold number TON Simplified method, paired, non-forced choice Laboratory Range PN-EN 1622:2006","technique_en":"Simplified method, paired, non-forced choice","test_object_en":"Water, water intended for human consumption","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"1"}],"search_zh":"水、生活饮用水 嗅阈值 TON 简化法，成对，非强制选择 实验室 范围 PN-EN 1622:2006","test_object_zh":"水、生活饮用水","technique_zh":"简化法，成对，非强制选择","methodology_zh":"嗅阈值 TON"},{"_id":"6a82ca6d884ede9a1b2c2d4e","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Liczba progowa zapachu TON","parameters":[{"name":"Zakres","range":"1 – 32"}],"technique":"Metoda pełna, parzysta, wybór niewymuszony","techniques":["Metoda pełna, parzysta, wybór niewymuszony"],"computed":[],"activity":"Liczba progowa zapachu TON\nZakres 1 – 32\nMetoda pełna, parzysta, wybór niewymuszony","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Liczba progowa zapachu TON\nZakres 1 – 32\nMetoda pełna, parzysta, wybór niewymuszony PN-EN 1622:2006 Woda, woda do spozycia przez ludzi Liczba progowa zapachu TON\nZakres 1 – 32\nMetoda pelna, parzysta, wybor niewymuszony PN-EN 1622:2006","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Odour threshold number TON","parameters_en":[{"name":"Range","range":"1 – 32"}],"search_en":"Water, water intended for human consumption Odour threshold number TON Full paired method, non-forced choice Laboratory Range PN-EN 1622:2006","technique_en":"Full paired method, non-forced choice","test_object_en":"Water, water intended for human consumption","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"1 – 32"}],"search_zh":"水、生活饮用水 嗅阈值 TON 完全法、成对法、非强制选择 实验室 范围 PN-EN 1622:2006","test_object_zh":"水、生活饮用水","methodology_zh":"嗅阈值 TON","technique_zh":"完全法、成对法、非强制选择"},{"_id":"6a82ca6d884ede9a1b2c2d4f","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Woda","methodology":"Absorbancja w UV","parameters":[{"name":"Zakres","range":"0,001 – 3,000"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Absorbancja w UV\nZakres 0,001 – 3,000\nMetoda spektrofotometryczna","reference":"PB/NW/32 wydanie 2 z dnia 02.12.2019 r.","norm_bases":["PB/NW/32 wydanie 2 z dnia 02.12.2019 r."],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Absorbancja w UV\nZakres 0,001 – 3,000\nMetoda spektrofotometryczna PB/NW/32 wydanie 2 z dnia 02.12.2019 r. Woda Absorbancja w UV\nZakres 0,001 – 3,000\nMetoda spektrofotometryczna PB/NW/32 wydanie 2 z dnia 02.12.2019 r.","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","parameters_en":[{"name":"Range","range":"0,001 – 3,000"}],"search_en":"Water Spectrophotometric method Laboratory Range PB/NW/32 wydanie 2 z dnia 02.12.2019 r.","technique_en":"Spectrophotometric method","test_object_en":"Water","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"0,001 – 3,000"}],"search_zh":"水 分光光度法 实验室 范围 PB/NW/32 wydanie 2 z dnia 02.12.2019 r.","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a82ca6d884ede9a1b2c2d50","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(0,50 – 5,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (0,50 – 5,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie azotu Kjeldahla\nZakres (0,50 – 5,0) mg/l\nMetoda spektrofotometryczna PN-EN 25663:2001 Woda Stezenie azotu Kjeldahla\nZakres (0,50 – 5,0) mg/l\nMetoda spektrofotometryczna PN-EN 25663:2001","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,50 – 5,0) mg/l"}],"search_en":"Water Kjeldahl nitrogen concentration Spectrophotometric method Laboratory Range PN-EN 25663:2001","technique_en":"Spectrophotometric method","test_object_en":"Water","lab_section_zh":"实验室","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(0,50 – 5,0) mg/l"}],"search_zh":"水 凯氏氮浓度 分光光度法 实验室 范围 PN-EN 25663:2001","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a82ca6d884ede9a1b2c2d51","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Woda","methodology":"Indeks fenolowy","parameters":[{"name":"Zakres","range":"(0,002 – 0,010) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Indeks fenolowy\nZakres (0,002 – 0,010) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6439:1994","norm_bases":["PN-ISO 6439:1994"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Indeks fenolowy\nZakres (0,002 – 0,010) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994 Woda Indeks fenolowy\nZakres (0,002 – 0,010) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Phenol index","parameters_en":[{"name":"Range","range":"(0,002 – 0,010) mg/l"}],"search_en":"Water Phenol index Spectrophotometric method Laboratory Range PN-ISO 6439:1994","technique_en":"Spectrophotometric method","test_object_en":"Water","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,002 – 0,010) mg/l"}],"search_zh":"水 酚指数 分光光度法 实验室 范围 PN-ISO 6439:1994","technique_zh":"分光光度法","test_object_zh":"水","methodology_zh":"酚指数"},{"_id":"6a82ca6d884ede9a1b2c2d52","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Woda","methodology":"Chemiczne zapotrzebowanie tlenu ChZT-Cr","parameters":[{"name":"Zakres","range":"(10 – 50) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu ChZT-Cr\nZakres (10 – 50) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Chemiczne zapotrzebowanie tlenu ChZT-Cr\nZakres (10 – 50) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda Chemiczne zapotrzebowanie tlenu ChZT-Cr\nZakres (10 – 50) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Chemical oxygen demand COD-Cr","parameters_en":[{"name":"Range","range":"(10 – 50) mg/l O2"}],"search_en":"Water Chemical oxygen demand COD-Cr Spectrophotometric method Laboratory Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Water","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(10 – 50) mg/l O2"}],"search_zh":"水 化学需氧量 COD-Cr 分光光度法 实验室 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水","methodology_zh":"化学需氧量 COD-Cr"},{"_id":"6a82ca6d884ede9a1b2c2d53","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Woda","methodology":"Całkowita substancja rozpuszczona (TDS)","parameters":[{"name":"Zakres","range":"(20 – 2000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Całkowita substancja rozpuszczona (TDS)\nZakres (20 – 2000) mg/l\nMetoda wagowa","reference":"PN-EN 15216:2022-03","norm_bases":["PN-EN 15216:2022-03"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Całkowita substancja rozpuszczona (TDS)\nZakres (20 – 2000) mg/l\nMetoda wagowa PN-EN 15216:2022-03 Woda Calkowita substancja rozpuszczona (TDS)\nZakres (20 – 2000) mg/l\nMetoda wagowa PN-EN 15216:2022-03","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","parameters_en":[{"name":"Range","range":"(20 – 2000) mg/l"}],"search_en":"Water Gravimetric method Laboratory Range PN-EN 15216:2022-03","technique_en":"Gravimetric method","test_object_en":"Water","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(20 – 2000) mg/l"}],"search_zh":"水 重量法 实验室 范围 PN-EN 15216:2022-03","technique_zh":"重量法","test_object_zh":"水"},{"_id":"6a82ca6d884ede9a1b2c2d54","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Woda","methodology":"Zasadowość ogólna","parameters":[{"name":"Zakres","range":"(20 – 500) mg/l CaCO3"},{"name":"Stężenie wodorowęglanów (z obliczeń)"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zasadowość ogólna\nZakres:\nZakres (20 – 500) mg/l CaCO3\nStężenie wodorowęglanów (z obliczeń)\nMetoda miareczkowa","reference":"PN-EN ISO 9963-1:2001 p. 8.2 +Ap1:2004","norm_bases":["PN-EN ISO 9963-1:2001 p. 8.2 +Ap1:2004"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Zasadowość ogólna\nZakres:\nZakres (20 – 500) mg/l CaCO3\nStężenie wodorowęglanów (z obliczeń)\nMetoda miareczkowa PN-EN ISO 9963-1:2001 p. 8.2 +Ap1:2004 Woda Zasadowosc ogolna\nZakres:\nZakres (20 – 500) mg/l CaCO3\nStezenie wodoroweglanow (z obliczen)\nMetoda miareczkowa PN-EN ISO 9963-1:2001 p. 8.2 +Ap1:2004","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total alkalinity","parameters_en":[{"name":"Range","range":"(20 – 500) mg/l CaCO3"},{"name":"Bicarbonate concentration (calculated)"}],"search_en":"Water Total alkalinity Titrimetric method Laboratory Range Bicarbonate concentration (calculated) PN-EN ISO 9963-1:2001 p. 8.2 +Ap1:2004","technique_en":"Titrimetric method","test_object_en":"Water","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(20 – 500) mg/l CaCO3"},{"name":"碳酸氢盐浓度（由计算得出）"}],"search_zh":"水 总碱度 滴定法 实验室 范围 碳酸氢盐浓度（由计算得出） PN-EN ISO 9963-1:2001 p. 8.2 +Ap1:2004","technique_zh":"滴定法","test_object_zh":"水","methodology_zh":"总碱度"},{"_id":"6a82ca6d884ede9a1b2c2d55","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Woda","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Zawiesiny ogólne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda Zawiesiny ogolne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 1000) mg/l"}],"search_en":"Water Total suspended solids (TSS) Gravimetric method Laboratory Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water","lab_section_zh":"实验室","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 1000) mg/l"}],"search_zh":"水 总悬浮物 重量法 实验室 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水"},{"_id":"6a82ca6d884ede9a1b2c2d56","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie bromków","parameters":[{"name":"Zakres","range":"(0,05 – 1,0) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie bromków\nZakres (0,05 – 1,0) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie bromków\nZakres (0,05 – 1,0) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda Stezenie bromkow\nZakres (0,05 – 1,0) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Bromide concentration","parameters_en":[{"name":"Range","range":"(0,05 – 1,0) mg/l"}],"search_en":"Water Bromide concentration Ion chromatography with conductometric detection (IC-CD) Laboratory Range PN-EN ISO 10304-1:2009+AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,05 – 1,0) mg/l"}],"search_zh":"水 溴化物浓度 离子色谱-电导检测法（IC-CD） 实验室 范围 PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水","methodology_zh":"溴化物浓度"},{"_id":"6a82ca6d884ede9a1b2c2d57","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Woda","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","parameters":[{"name":"Zakres","range":"(0,5 – 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Biochemical oxygen demand - BOD5","parameters_en":[{"name":"Range","range":"(0,5 – 6,0) mg/l O2"}],"search_en":"Water Biochemical oxygen demand - BOD5 Electrochemical method Laboratory Range PN-EN 1899-2:2002","technique_en":"Electrochemical method","test_object_en":"Water","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,5 – 6,0) mg/l O2"}],"search_zh":"水 五日生化需氧量（BOD5） 电化学法 实验室 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a82ca6d884ede9a1b2c2d58","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Woda","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","parameters":[{"name":"Zakres","range":"(0,5 – 6,0) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda optyczna","reference":"PN-EN 1899-2:2002 z wył. p. 7.2 | PB/NW/45 wydanie 1 z dnia 08.02.2019 r.","norm_bases":["PN-EN 1899-2:2002 z wył. p. 7.2","PB/NW/45 wydanie 1 z dnia 08.02.2019 r."],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda optyczna PN-EN 1899-2:2002 z wył. p. 7.2 | PB/NW/45 wydanie 1 z dnia 08.02.2019 r. Woda Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda optyczna PN-EN 1899-2:2002 z wyl. p. 7.2 | PB/NW/45 wydanie 1 z dnia 08.02.2019 r.","categories":["water"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Biochemical oxygen demand - BOD5","parameters_en":[{"name":"Range","range":"(0,5 – 6,0) mg/l O2"}],"search_en":"Water Biochemical oxygen demand - BOD5 Optical method Laboratory Range PN-EN 1899-2:2002 z wył. p. 7.2 | PB/NW/45 wydanie 1 z dnia 08.02.2019 r.","technique_en":"Optical method","test_object_en":"Water","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,5 – 6,0) mg/l O2"}],"search_zh":"水 五日生化需氧量（BOD5） 光学法 实验室 范围 PN-EN 1899-2:2002 z wył. p. 7.2 | PB/NW/45 wydanie 1 z dnia 08.02.2019 r.","technique_zh":"光学法","test_object_zh":"水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a82ca6d884ede9a1b2c2d59","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie ogólnego węgla organicznego (OWO) i rozpuszczonego węgla organicznego (RWO)","parameters":[{"name":"Zakres","range":"(0,50 – 1000) mg/l"}],"technique":"Metoda spektrometrii w podczerwieni (IR)","techniques":["Metoda spektrometrii w podczerwieni (IR)"],"computed":[],"activity":"Stężenie ogólnego węgla organicznego (OWO) i rozpuszczonego węgla organicznego (RWO)\nZakres (0,50 – 1000) mg/l\nMetoda spektrometrii w podczerwieni (IR)","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie ogólnego węgla organicznego (OWO) i rozpuszczonego węgla organicznego (RWO)\nZakres (0,50 – 1000) mg/l\nMetoda spektrometrii w podczerwieni (IR) PN-EN 1484:1999 Woda, woda do spozycia przez ludzi, scieki Stezenie ogolnego wegla organicznego (OWO) i rozpuszczonego wegla organicznego (RWO)\nZakres (0,50 – 1000) mg/l\nMetoda spektrometrii w podczerwieni (IR) PN-EN 1484:1999","categories":["water"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","parameters_en":[{"name":"Range","range":"(0,50 – 1000) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Infrared spectrometry method (IR) Laboratory Range PN-EN 1484:1999","technique_en":"Infrared spectrometry method (IR)","test_object_en":"Water, water intended for human consumption, wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,50 – 1000) mg/l"}],"search_zh":"水、生活饮用水、污水 红外光谱法（IR） 实验室 范围 PN-EN 1484:1999","test_object_zh":"水、生活饮用水、污水","technique_zh":"红外光谱法（IR）"},{"_id":"6a82ca6d884ede9a1b2c2d5a","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(74,0 – 2770) µS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (74,0 – 2770) µS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Przewodność elektryczna właściwa\nZakres (74,0 – 2770) µS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, woda do spozycia przez ludzi, scieki Przewodnosc elektryczna wlasciwa\nZakres (74,0 – 2770) µS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(74,0 – 2770) µS/cm"}],"search_en":"Water, water intended for human consumption, wastewater Electrical conductivity Conductometric method Laboratory Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, water intended for human consumption, wastewater","lab_section_zh":"实验室","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(74,0 – 2770) µS/cm"}],"search_zh":"水、生活饮用水、污水 电导率 电导法 实验室 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a82ca6d884ede9a1b2c2d5b","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie żelaza","parameters":[{"name":"Zakres","range":"(0,010 – 15,0) mg/l"}],"technique":"Metoda optycznej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda optycznej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie żelaza\nZakres (0,010 – 15,0) mg/l\nMetoda optycznej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie żelaza\nZakres (0,010 – 15,0) mg/l\nMetoda optycznej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Woda, woda do spozycia przez ludzi, scieki Stezenie zelaza\nZakres (0,010 – 15,0) mg/l\nMetoda optycznej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Iron concentration","parameters_en":[{"name":"Range","range":"(0,010 – 15,0) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Iron concentration Inductively coupled plasma optical emission spectrometry (ICP-OES) Laboratory Range PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Water, water intended for human consumption, wastewater","lab_section_zh":"实验室","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 15,0) mg/l"}],"search_zh":"水、生活饮用水、污水 铁浓度 电感耦合等离子体光学发射光谱法（ICP-OES） 实验室 范围 PN-EN ISO 11885:2009","test_object_zh":"水、生活饮用水、污水","technique_zh":"电感耦合等离子体光学发射光谱法（ICP-OES）"},{"_id":"6a82ca6d884ede9a1b2c2d5c","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","parameters":[{"name":"Zakres","range":"(1 – 6000) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1 – 6000) mg/l O2\nMetoda optyczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1 – 6000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12 Woda, scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1 – 6000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Biochemical oxygen demand - BOD5","parameters_en":[{"name":"Range","range":"(1 – 6000) mg/l O2"}],"search_en":"Water, wastewater Biochemical oxygen demand - BOD5 Optical method Laboratory Range PN-EN ISO 5815-1:2019-12","technique_en":"Optical method","test_object_en":"Water, wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(1 – 6000) mg/l O2"}],"search_zh":"水、废水 五日生化需氧量（BOD5） 光学法 实验室 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"光学法","test_object_zh":"水、废水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a82ca6d884ede9a1b2c2d5d","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie tlenu rozpuszczonego","parameters":[{"name":"Zakres","range":"(0,5 – 14,0) mg/l"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie tlenu rozpuszczonego\nZakres (0,5 – 14,0) mg/l\nMetoda elektrochemiczna","reference":"PN-EN ISO 5814:2013","norm_bases":["PN-EN ISO 5814:2013"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie tlenu rozpuszczonego\nZakres (0,5 – 14,0) mg/l\nMetoda elektrochemiczna PN-EN ISO 5814:2013 Woda, scieki Stezenie tlenu rozpuszczonego\nZakres (0,5 – 14,0) mg/l\nMetoda elektrochemiczna PN-EN ISO 5814:2013","categories":["water"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Dissolved oxygen concentration","parameters_en":[{"name":"Range","range":"(0,5 – 14,0) mg/l"}],"search_en":"Water, wastewater Dissolved oxygen concentration Electrochemical method Laboratory Range PN-EN ISO 5814:2013","technique_en":"Electrochemical method","test_object_en":"Water, wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,5 – 14,0) mg/l"}],"search_zh":"水、废水 溶解氧浓度 电化学法 实验室 范围 PN-EN ISO 5814:2013","technique_zh":"电化学法","test_object_zh":"水、废水","methodology_zh":"溶解氧浓度"},{"_id":"6a82ca6d884ede9a1b2c2d5e","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie tlenu rozpuszczonego","parameters":[{"name":"Zakres","range":"(0,5 – 14,0) mg/l"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Stężenie tlenu rozpuszczonego\nZakres (0,5 – 14,0) mg/l\nMetoda optyczna","reference":"PB/NW/45 wydanie 1 z dnia 08.02.2019 r.","norm_bases":["PB/NW/45 wydanie 1 z dnia 08.02.2019 r."],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie tlenu rozpuszczonego\nZakres (0,5 – 14,0) mg/l\nMetoda optyczna PB/NW/45 wydanie 1 z dnia 08.02.2019 r. Woda, scieki Stezenie tlenu rozpuszczonego\nZakres (0,5 – 14,0) mg/l\nMetoda optyczna PB/NW/45 wydanie 1 z dnia 08.02.2019 r.","categories":["water"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Dissolved oxygen concentration","parameters_en":[{"name":"Range","range":"(0,5 – 14,0) mg/l"}],"search_en":"Water, wastewater Dissolved oxygen concentration Optical method Laboratory Range PB/NW/45 wydanie 1 z dnia 08.02.2019 r.","technique_en":"Optical method","test_object_en":"Water, wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,5 – 14,0) mg/l"}],"search_zh":"水、废水 溶解氧浓度 光学法 实验室 范围 PB/NW/45 wydanie 1 z dnia 08.02.2019 r.","technique_zh":"光学法","test_object_zh":"水、废水","methodology_zh":"溶解氧浓度"},{"_id":"6a82ca6d884ede9a1b2c2d5f","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu ogólnego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PB/NW/21 wydanie 4 z dnia 02.12.2019 r.","norm_bases":["PB/NW/21 wydanie 4 z dnia 02.12.2019 r."],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu ogólnego (z obliczeń) PB/NW/21 wydanie 4 z dnia 02.12.2019 r. Woda, scieki Stezenie azotu ogolnego (z obliczen) PB/NW/21 wydanie 4 z dnia 02.12.2019 r.","categories":["water"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total nitrogen concentration (calculated)","search_en":"Water, wastewater Total nitrogen concentration (calculated) Laboratory PB/NW/21 wydanie 4 z dnia 02.12.2019 r.","test_object_en":"Water, wastewater","lab_section_zh":"实验室","methodology_zh":"总氮浓度（计算值）","search_zh":"水、废水 总氮浓度（计算值） 实验室 PB/NW/21 wydanie 4 z dnia 02.12.2019 r.","test_object_zh":"水、废水"},{"_id":"6a82ca6d884ede9a1b2c2d60","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5 – 1200) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5 – 1200) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie chlorków\nZakres (5 – 1200) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, scieki Stezenie chlorkow\nZakres (5 – 1200) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5 – 1200) mg/l"}],"search_en":"Water, wastewater Chloride concentration Titrimetric method Laboratory Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","lab_section_zh":"实验室","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5 – 1200) mg/l"}],"search_zh":"水、废水 氯化物浓度 滴定法 实验室 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a82ca6d884ede9a1b2c2d61","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Indeks oleju mineralnego","parameters":[{"name":"Zakres","range":"(0,10 – 50) mg/l"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Indeks oleju mineralnego\nZakres (0,10 – 50) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 9377-2:2003","norm_bases":["PN-EN ISO 9377-2:2003"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Indeks oleju mineralnego\nZakres (0,10 – 50) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 9377-2:2003 Woda, scieki Indeks oleju mineralnego\nZakres (0,10 – 50) mg/l\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 9377-2:2003","categories":["water","petro"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Mineral oil index","parameters_en":[{"name":"Range","range":"(0,10 – 50) mg/l"}],"search_en":"Water, wastewater Mineral oil index Gas chromatography with flame ionization detection (GC-FID) Laboratory Range PN-EN ISO 9377-2:2003","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Water, wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,10 – 50) mg/l"}],"search_zh":"水、废水 矿物油指数 气相色谱-氢火焰离子化检测法（GC-FID） 实验室 范围 PN-EN ISO 9377-2:2003","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"水、废水","methodology_zh":"矿物油指数"},{"_id":"6a82ca6d884ede9a1b2c2d62","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007","norm_bases":["PN-EN ISO 19458:2007"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 Woda, woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007","categories":["water","microbiology"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sampling for microbiological testing","search_en":"Water, water intended for human consumption Sampling for microbiological testing Laboratory PN-EN ISO 19458:2007","test_object_en":"Water, water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"微生物检测用样品采集","search_zh":"水、生活饮用水 微生物检测用样品采集 实验室 PN-EN ISO 19458:2007","test_object_zh":"水、生活饮用水"},{"_id":"6a82ca6d884ede9a1b2c2d63","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w 22 ºC","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 22 ºC\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 22 ºC\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda, woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 22 ºC\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","search_en":"Water, water intended for human consumption Plate method (pour plate) Laboratory PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water, water intended for human consumption","lab_section_zh":"实验室","search_zh":"水、生活饮用水 平板法（倾注培养） 实验室 PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水"},{"_id":"6a82ca6d884ede9a1b2c2d64","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Liczba bakterii grupy coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda, woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Coliform bacteria count","search_en":"Water, water intended for human consumption Coliform bacteria count Membrane filtration method Laboratory PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water, water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"大肠菌群计数","search_zh":"水、生活饮用水 大肠菌群计数 膜过滤法 实验室 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a82ca6d884ede9a1b2c2d65","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Liczba Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda, woda do spozycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Escherichia coli count","search_en":"Water, water intended for human consumption Escherichia coli count Membrane filtration method Laboratory PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water, water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"水、生活饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 实验室 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a82ca6d884ede9a1b2c2d66","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Liczba enterokoków","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Liczba enterokoków\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda, woda do spozycia przez ludzi Liczba enterokokow\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Enterococci count","search_en":"Water, water intended for human consumption Enterococci count Membrane filtration method Laboratory PN-EN ISO 7899-2:2004","technique_en":"Membrane filtration method","test_object_en":"Water, water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"肠球菌计数","search_zh":"水、生活饮用水 肠球菌计数 膜过滤法 实验室 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a82ca6d884ede9a1b2c2d67","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Liczba Clostridium perfringens łącznie z przetrwalnikami (sporami)","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Clostridium perfringens łącznie z przetrwalnikami (sporami)\nMetoda filtracji membranowej","reference":"PN-EN ISO 14189:2016-10","norm_bases":["PN-EN ISO 14189:2016-10"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Liczba Clostridium perfringens łącznie z przetrwalnikami (sporami)\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10 Woda, woda do spozycia przez ludzi Liczba Clostridium perfringens lacznie z przetrwalnikami (sporami)\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10","categories":["water"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","search_en":"Water, water intended for human consumption Membrane filtration method Laboratory PN-EN ISO 14189:2016-10","technique_en":"Membrane filtration method","test_object_en":"Water, water intended for human consumption","lab_section_zh":"实验室","search_zh":"水、生活饮用水 膜过滤法 实验室 PN-EN ISO 14189:2016-10","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a82ca6d884ede9a1b2c2d68","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Woda","methodology":"Ogólna liczba mikroorganizmów w 36 ºC","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 36 ºC\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Ogólna liczba mikroorganizmów w 36 ºC\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda Ogolna liczba mikroorganizmow w 36 ºC\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","search_en":"Water Plate method (pour plate) Laboratory PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water","lab_section_zh":"实验室","search_zh":"水 平板法（倾注培养） 实验室 PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水"},{"_id":"6a82ca6d884ede9a1b2c2d69","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Woda","methodology":"Liczba Pseudomonas aeruginosa","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Pseudomonas aeruginosa count","search_en":"Water Pseudomonas aeruginosa count Membrane filtration method Laboratory PN-EN ISO 16266:2009","technique_en":"Membrane filtration method","test_object_en":"Water","lab_section_zh":"实验室","methodology_zh":"铜绿假单胞菌计数","search_zh":"水 铜绿假单胞菌计数 膜过滤法 实验室 PN-EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"水"},{"_id":"6a82ca6d884ede9a1b2c2d6a","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,033 – 48,9) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,033 – 48,9) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 rozdział 8 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 rozdział 8 +Ap1:2010+Ap2:2010"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie fosforu ogólnego\nZakres (0,033 – 48,9) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 rozdział 8 +Ap1:2010+Ap2:2010 Scieki Stezenie fosforu ogolnego\nZakres (0,033 – 48,9) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 rozdzial 8 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,033 – 48,9) mg/l"}],"search_en":"Wastewater Total phosphorus concentration Spectrophotometric method Laboratory Range PN-EN ISO 6878:2006 rozdział 8 +Ap1:2010+Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,033 – 48,9) mg/l"}],"search_zh":"污水 总磷浓度 分光光度法 实验室 范围 PN-EN ISO 6878:2006 rozdział 8 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a82ca6d884ede9a1b2c2d6b","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Ścieki","methodology":"Indeks fenolowy","parameters":[{"name":"Zakres","range":"(0,002 – 1,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Indeks fenolowy\nZakres (0,002 – 1,00) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6439:1994","norm_bases":["PN-ISO 6439:1994"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Indeks fenolowy\nZakres (0,002 – 1,00) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994 Scieki Indeks fenolowy\nZakres (0,002 – 1,00) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994","categories":["water"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Phenol index","parameters_en":[{"name":"Range","range":"(0,002 – 1,00) mg/l"}],"search_en":"Wastewater Phenol index Spectrophotometric method Laboratory Range PN-ISO 6439:1994","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,002 – 1,00) mg/l"}],"search_zh":"污水 酚指数 分光光度法 实验室 范围 PN-ISO 6439:1994","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"酚指数"},{"_id":"6a82ca6d884ede9a1b2c2d6c","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie anionów","parameters":[{"name":"Azotany","range":"(0,10 – 200) mg/l"},{"name":"Azotyny","range":"(0,10 – 70) mg/l"},{"name":"Chlorki","range":"(0,50 – 500) mg/l"},{"name":"Fosforany","range":"(0,10 – 190) mg/l"},{"name":"Siarczany","range":"(0,50 – 250) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów\nZakres:\nAzotany (0,10 – 200) mg/l\nAzotyny (0,10 – 70) mg/l\nChlorki (0,50 – 500) mg/l\nFosforany (0,10 – 190) mg/l\nSiarczany (0,50 – 250) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009 +AC:2012","norm_bases":["PN-EN ISO 10304-1:2009 +AC:2012"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie anionów\nZakres:\nAzotany (0,10 – 200) mg/l\nAzotyny (0,10 – 70) mg/l\nChlorki (0,50 – 500) mg/l\nFosforany (0,10 – 190) mg/l\nSiarczany (0,50 – 250) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009 +AC:2012 Scieki Stezenie anionow\nZakres:\nAzotany (0,10 – 200) mg/l\nAzotyny (0,10 – 70) mg/l\nChlorki (0,50 – 500) mg/l\nFosforany (0,10 – 190) mg/l\nSiarczany (0,50 – 250) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009 +AC:2012","categories":["water"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Anion concentrations","parameters_en":[{"name":"Nitrates","range":"(0,10 – 200) mg/l"},{"name":"Nitrites","range":"(0,10 – 70) mg/l"},{"name":"Chlorides","range":"(0,50 – 500) mg/l"},{"name":"Phosphates","range":"(0,10 – 190) mg/l"},{"name":"Sulfates","range":"(0,50 – 250) mg/l"}],"search_en":"Wastewater Anion concentrations Ion chromatography with conductometric detection (IC-CD) Laboratory Nitrates Nitrites Chlorides Phosphates Sulfates PN-EN ISO 10304-1:2009 +AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"阴离子浓度","parameters_zh":[{"name":"硝酸盐","range":"(0,10 – 200) mg/l"},{"name":"亚硝酸盐","range":"(0,10 – 70) mg/l"},{"name":"氯化物","range":"(0,50 – 500) mg/l"},{"name":"磷酸盐","range":"(0,10 – 190) mg/l"},{"name":"硫酸盐","range":"(0,50 – 250) mg/l"}],"search_zh":"污水 阴离子浓度 离子色谱-电导检测法（IC-CD） 实验室 硝酸盐 亚硝酸盐 氯化物 磷酸盐 硫酸盐 PN-EN ISO 10304-1:2009 +AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"污水"},{"_id":"6a82ca6d884ede9a1b2c2d6d","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(2,0 – 250) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (2,0 – 250) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu Kjeldahla\nZakres (2,0 – 250) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Scieki Stezenie azotu Kjeldahla\nZakres (2,0 – 250) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(2,0 – 250) mg/l"}],"search_en":"Wastewater Kjeldahl nitrogen concentration Titrimetric method Laboratory Range PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(2,0 – 250) mg/l"}],"search_zh":"污水 凯氏氮浓度 滴定法 实验室 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a82ca6d884ede9a1b2c2d6e","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu ChZT-Cr","parameters":[{"name":"Zakres","range":"(10 – 10000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu ChZT-Cr\nZakres (10 – 10000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu ChZT-Cr\nZakres (10 – 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Scieki Chemiczne zapotrzebowanie tlenu ChZT-Cr\nZakres (10 – 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Chemical oxygen demand COD-Cr","parameters_en":[{"name":"Range","range":"(10 – 10000) mg/l O2"}],"search_en":"Wastewater Chemical oxygen demand COD-Cr Spectrophotometric method Laboratory Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(10 – 10000) mg/l O2"}],"search_zh":"污水 化学需氧量 COD-Cr 分光光度法 实验室 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"化学需氧量 COD-Cr"},{"_id":"6a82ca6d884ede9a1b2c2d6f","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki pH\nZakres 4,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Scieki pH\nZakres 4,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 12,0"}],"search_en":"Wastewater pH Potentiometric method Laboratory Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 12,0"}],"search_zh":"污水 pH 值 电位法 实验室 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"污水"},{"_id":"6a82ca6d884ede9a1b2c2d70","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Ścieki","methodology":"Zasadowość ogólna","parameters":[{"name":"Zakres","range":"(20 – 1000) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zasadowość ogólna\nZakres (20 – 1000) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-EN ISO 9963-1:2001 p. 8.2 +Ap1:2004","norm_bases":["PN-EN ISO 9963-1:2001 p. 8.2 +Ap1:2004"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Zasadowość ogólna\nZakres (20 – 1000) mg/l CaCO3\nMetoda miareczkowa PN-EN ISO 9963-1:2001 p. 8.2 +Ap1:2004 Scieki Zasadowosc ogolna\nZakres (20 – 1000) mg/l CaCO3\nMetoda miareczkowa PN-EN ISO 9963-1:2001 p. 8.2 +Ap1:2004","categories":["water"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total alkalinity","parameters_en":[{"name":"Range","range":"(20 – 1000) mg/l CaCO3"}],"search_en":"Wastewater Total alkalinity Titrimetric method Laboratory Range PN-EN ISO 9963-1:2001 p. 8.2 +Ap1:2004","technique_en":"Titrimetric method","test_object_en":"Wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(20 – 1000) mg/l CaCO3"}],"search_zh":"污水 总碱度 滴定法 实验室 范围 PN-EN ISO 9963-1:2001 p. 8.2 +Ap1:2004","technique_zh":"滴定法","test_object_zh":"污水","methodology_zh":"总碱度"},{"_id":"6a82ca6d884ede9a1b2c2d71","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(1,0 – 250) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (1,0 – 250) mg/l\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu amonowego\nZakres (1,0 – 250) mg/l\nMetoda miareczkowa PN-ISO 5664:2002 Scieki Stezenie azotu amonowego\nZakres (1,0 – 250) mg/l\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(1,0 – 250) mg/l"}],"search_en":"Wastewater Ammonium nitrogen concentration Titrimetric method Laboratory Range PN-ISO 5664:2002","technique_en":"Titrimetric method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(1,0 – 250) mg/l"}],"search_zh":"污水 氨氮浓度 滴定法 实验室 范围 PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a82ca6d884ede9a1b2c2d72","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie substancji ekstrahujących się eterem naftowym","parameters":[{"name":"Zakres","range":"(5,0 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie substancji ekstrahujących się eterem naftowym\nZakres (5,0 – 1000) mg/l\nMetoda wagowa","reference":"PB/NW/5 wydanie 4 z dnia 02.12.2019 r.","norm_bases":["PB/NW/5 wydanie 4 z dnia 02.12.2019 r."],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie substancji ekstrahujących się eterem naftowym\nZakres (5,0 – 1000) mg/l\nMetoda wagowa PB/NW/5 wydanie 4 z dnia 02.12.2019 r. Scieki Stezenie substancji ekstrahujacych sie eterem naftowym\nZakres (5,0 – 1000) mg/l\nMetoda wagowa PB/NW/5 wydanie 4 z dnia 02.12.2019 r.","categories":["water"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Concentration of substances extractable with petroleum ether","parameters_en":[{"name":"Range","range":"(5,0 – 1000) mg/l"}],"search_en":"Wastewater Concentration of substances extractable with petroleum ether Gravimetric method Laboratory Range PB/NW/5 wydanie 4 z dnia 02.12.2019 r.","technique_en":"Gravimetric method","test_object_en":"Wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(5,0 – 1000) mg/l"}],"search_zh":"污水 石油醚可萃取物浓度 重量法 实验室 范围 PB/NW/5 wydanie 4 z dnia 02.12.2019 r.","technique_zh":"重量法","test_object_zh":"污水","methodology_zh":"石油醚可萃取物浓度"},{"_id":"6a82ca6d884ede9a1b2c2d73","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie surfaktantów niejonowych","parameters":[{"name":"Zakres","range":"(0,4 – 70) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie surfaktantów niejonowych\nZakres (0,4 – 70) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7875-2:2002","norm_bases":["PN-ISO 7875-2:2002"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie surfaktantów niejonowych\nZakres (0,4 – 70) mg/l\nMetoda spektrofotometryczna PN-ISO 7875-2:2002 Scieki Stezenie surfaktantow niejonowych\nZakres (0,4 – 70) mg/l\nMetoda spektrofotometryczna PN-ISO 7875-2:2002","categories":["water"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Non-ionic surfactant concentration","parameters_en":[{"name":"Range","range":"(0,4 – 70) mg/l"}],"search_en":"Wastewater Non-ionic surfactant concentration Spectrophotometric method Laboratory Range PN-ISO 7875-2:2002","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,4 – 70) mg/l"}],"search_zh":"污水 非离子表面活性剂浓度 分光光度法 实验室 范围 PN-ISO 7875-2:2002","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"非离子表面活性剂浓度"},{"_id":"6a82ca6d884ede9a1b2c2d74","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 10 000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 10 000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Zawiesiny ogólne\nZakres (2,0 – 10 000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Scieki Zawiesiny ogolne\nZakres (2,0 – 10 000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 10 000) mg/l"}],"search_en":"Wastewater Total suspended solids (TSS) Gravimetric method Laboratory Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 10 000) mg/l"}],"search_zh":"污水 总悬浮物 重量法 实验室 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"污水"},{"_id":"6a82ca6d884ede9a1b2c2d75","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sampling for chemical and physical testing","search_en":"Wastewater Sampling for chemical and physical testing Manual method; Automatic method Laboratory PN-ISO 5667-10:2021-11","technique_en":"Manual method; Automatic method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水 化学与物理检测用样品采集 手动法；自动法 实验室 PN-ISO 5667-10:2021-11","technique_zh":"手动法；自动法","test_object_zh":"污水"},{"_id":"6a82ca6d884ede9a1b2c2d76","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Ścieki","methodology":"Temperatura","parameters":[{"name":"Zakres","range":"(2,0 – 50,0) ºC"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura\nZakres (2,0 – 50,0) ºC","reference":"PB/NW/19 wydanie 4 z dnia 02.12.2019 r.","norm_bases":["PB/NW/19 wydanie 4 z dnia 02.12.2019 r."],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Temperatura\nZakres (2,0 – 50,0) ºC PB/NW/19 wydanie 4 z dnia 02.12.2019 r. Scieki Temperatura\nZakres (2,0 – 50,0) ºC PB/NW/19 wydanie 4 z dnia 02.12.2019 r.","categories":["water"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Temperature","parameters_en":[{"name":"Range","range":"(2,0 – 50,0) ºC"}],"search_en":"Wastewater Temperature Laboratory Range PB/NW/19 wydanie 4 z dnia 02.12.2019 r.","test_object_en":"Wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(2,0 – 50,0) ºC"}],"search_zh":"污水 温度 实验室 范围 PB/NW/19 wydanie 4 z dnia 02.12.2019 r.","test_object_zh":"污水","methodology_zh":"温度"},{"_id":"6a82ca6d884ede9a1b2c2d77","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie pierwiastków","parameters":[{"name":"Ag","range":"(0,010 – 1,00) mg/l"},{"name":"As","range":"(0,020 – 1,00) mg/l"},{"name":"Cd","range":"(0,010 – 0,500) mg/l"},{"name":"Cr","range":"(0,010 – 5,00) mg/l"},{"name":"Cu","range":"(0,010 – 2,00) mg/l"},{"name":"Ni","range":"(0,010 – 2,00) mg/l"},{"name":"Pb","range":"(0,010 – 2,00) mg/l"},{"name":"V","range":"(0,010 – 2,00) mg/l"},{"name":"Zn","range":"(0,010 – 10,0) mg/l"},{"name":"Pog","range":"(0,100 – 70,0) mg/l"}],"technique":"Metoda optycznej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda optycznej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie pierwiastków\nZakres:\nAg (0,010 – 1,00) mg/l\nAs (0,020 – 1,00) mg/l\nCd (0,010 – 0,500) mg/l\nCr (0,010 – 5,00) mg/l\nCu (0,010 – 2,00) mg/l\nNi (0,010 – 2,00) mg/l\nPb (0,010 – 2,00) mg/l\nV (0,010 – 2,00) mg/l\nZn (0,010 – 10,0) mg/l\nPog (0,100 – 70,0) mg/l\nMetoda optycznej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie pierwiastków\nZakres:\nAg (0,010 – 1,00) mg/l\nAs (0,020 – 1,00) mg/l\nCd (0,010 – 0,500) mg/l\nCr (0,010 – 5,00) mg/l\nCu (0,010 – 2,00) mg/l\nNi (0,010 – 2,00) mg/l\nPb (0,010 – 2,00) mg/l\nV (0,010 – 2,00) mg/l\nZn (0,010 – 10,0) mg/l\nPog (0,100 – 70,0) mg/l\nMetoda optycznej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Scieki Stezenie pierwiastkow\nZakres:\nAg (0,010 – 1,00) mg/l\nAs (0,020 – 1,00) mg/l\nCd (0,010 – 0,500) mg/l\nCr (0,010 – 5,00) mg/l\nCu (0,010 – 2,00) mg/l\nNi (0,010 – 2,00) mg/l\nPb (0,010 – 2,00) mg/l\nV (0,010 – 2,00) mg/l\nZn (0,010 – 10,0) mg/l\nPog (0,100 – 70,0) mg/l\nMetoda optycznej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Element concentration","parameters_en":[{"name":"Ag","range":"(0,010 – 1,00) mg/l"},{"name":"As","range":"(0,020 – 1,00) mg/l"},{"name":"Cd","range":"(0,010 – 0,500) mg/l"},{"name":"Cr","range":"(0,010 – 5,00) mg/l"},{"name":"Cu","range":"(0,010 – 2,00) mg/l"},{"name":"Ni","range":"(0,010 – 2,00) mg/l"},{"name":"Pb","range":"(0,010 – 2,00) mg/l"},{"name":"V","range":"(0,010 – 2,00) mg/l"},{"name":"Zn","range":"(0,010 – 10,0) mg/l"},{"name":"Pog","range":"(0,100 – 70,0) mg/l"}],"search_en":"Wastewater Element concentration Inductively coupled plasma optical emission spectrometry (ICP-OES) Laboratory Ag As Cd Cr Cu Ni Pb V Zn PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"元素浓度","parameters_zh":[{"name":"Ag","range":"(0,010 – 1,00) mg/l"},{"name":"As","range":"(0,020 – 1,00) mg/l"},{"name":"Cd","range":"(0,010 – 0,500) mg/l"},{"name":"Cr","range":"(0,010 – 5,00) mg/l"},{"name":"Cu","range":"(0,010 – 2,00) mg/l"},{"name":"Ni","range":"(0,010 – 2,00) mg/l"},{"name":"Pb","range":"(0,010 – 2,00) mg/l"},{"name":"V","range":"(0,010 – 2,00) mg/l"},{"name":"Zn","range":"(0,010 – 10,0) mg/l"},{"name":"Pog","range":"(0,100 – 70,0) mg/l"}],"search_zh":"污水 元素浓度 电感耦合等离子体光学发射光谱法（ICP-OES） 实验室 Ag As Cd Cr Cu Ni Pb V Zn PN-EN ISO 11885:2009","test_object_zh":"污水","technique_zh":"电感耦合等离子体光学发射光谱法（ICP-OES）"},{"_id":"6a82ca6d884ede9a1b2c2d78","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość azotu amonowego","parameters":[{"name":"Zakres","range":"(0,10 – 1,60) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu amonowego\nZakres (0,10 – 1,60) %\nMetoda miareczkowa","reference":"PN-EN 14671:2007 | PN-ISO 5664:2002","norm_bases":["PN-EN 14671:2007","PN-ISO 5664:2002"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość azotu amonowego\nZakres (0,10 – 1,60) %\nMetoda miareczkowa PN-EN 14671:2007 | PN-ISO 5664:2002 Osady sciekowe Zawartosc azotu amonowego\nZakres (0,10 – 1,60) %\nMetoda miareczkowa PN-EN 14671:2007 | PN-ISO 5664:2002","categories":["water"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Ammonium nitrogen content","parameters_en":[{"name":"Range","range":"(0,10 – 1,60) %"}],"search_en":"Sewage sludge Ammonium nitrogen content Titrimetric method Laboratory Range PN-EN 14671:2007 | PN-ISO 5664:2002","technique_en":"Titrimetric method","test_object_en":"Sewage sludge","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,10 – 1,60) %"}],"search_zh":"污泥 氨氮含量 滴定法 实验室 范围 PN-EN 14671:2007 | PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"污泥","methodology_zh":"氨氮含量"},{"_id":"6a82ca6d884ede9a1b2c2d79","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość azotu ogólnego","parameters":[{"name":"Zakres","range":"(0,10 – 10,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu ogólnego\nZakres (0,10 – 10,0) %\nMetoda miareczkowa","reference":"PN-EN 13342:2002 | PN-EN 25663:2001","norm_bases":["PN-EN 13342:2002","PN-EN 25663:2001"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość azotu ogólnego\nZakres (0,10 – 10,0) %\nMetoda miareczkowa PN-EN 13342:2002 | PN-EN 25663:2001 Osady sciekowe Zawartosc azotu ogolnego\nZakres (0,10 – 10,0) %\nMetoda miareczkowa PN-EN 13342:2002 | PN-EN 25663:2001","categories":["water"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total nitrogen content","parameters_en":[{"name":"Range","range":"(0,10 – 10,0) %"}],"search_en":"Sewage sludge Total nitrogen content Titrimetric method Laboratory Range PN-EN 13342:2002 | PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Sewage sludge","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,10 – 10,0) %"}],"search_zh":"污泥 总氮含量 滴定法 实验室 范围 PN-EN 13342:2002 | PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"污泥","methodology_zh":"总氮含量"},{"_id":"6a82ca6d884ede9a1b2c2d7a","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Strata przy prażeniu suchej masy osadu - substancje organiczne","parameters":[{"name":"Zakres","range":"(1,0 – 99,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Strata przy prażeniu suchej masy osadu - substancje organiczne\nZakres (1,0 – 99,0) %\nMetoda wagowa","reference":"PN-EN 15935:2022-01 p. 7.3","norm_bases":["PN-EN 15935:2022-01 p. 7.3"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Strata przy prażeniu suchej masy osadu - substancje organiczne\nZakres (1,0 – 99,0) %\nMetoda wagowa PN-EN 15935:2022-01 p. 7.3 Osady sciekowe Strata przy prazeniu suchej masy osadu - substancje organiczne\nZakres (1,0 – 99,0) %\nMetoda wagowa PN-EN 15935:2022-01 p. 7.3","categories":["water"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","parameters_en":[{"name":"Range","range":"(1,0 – 99,0) %"}],"search_en":"Sewage sludge Gravimetric method Laboratory Range PN-EN 15935:2022-01 p. 7.3","technique_en":"Gravimetric method","test_object_en":"Sewage sludge","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(1,0 – 99,0) %"}],"search_zh":"污泥 重量法 实验室 范围 PN-EN 15935:2022-01 p. 7.3","technique_zh":"重量法","test_object_zh":"污泥"},{"_id":"6a82ca6d884ede9a1b2c2d7b","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Sucha pozostałość i zawartość wody – sucha masa","parameters":[{"name":"Zakres","range":"(0,50 – 99,5) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha pozostałość i zawartość wody – sucha masa\nZakres (0,50 – 99,5) %\nMetoda wagowa","reference":"PN-EN 15934:2013-02 Metoda A","norm_bases":["PN-EN 15934:2013-02 Metoda A"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Sucha pozostałość i zawartość wody – sucha masa\nZakres (0,50 – 99,5) %\nMetoda wagowa PN-EN 15934:2013-02 Metoda A Osady sciekowe Sucha pozostalosc i zawartosc wody – sucha masa\nZakres (0,50 – 99,5) %\nMetoda wagowa PN-EN 15934:2013-02 Metoda A","categories":["water"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","parameters_en":[{"name":"Range","range":"(0,50 – 99,5) %"}],"search_en":"Sewage sludge Gravimetric method Laboratory Range PN-EN 15934:2013-02 Metoda A","technique_en":"Gravimetric method","test_object_en":"Sewage sludge","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,50 – 99,5) %"}],"search_zh":"污泥 重量法 实验室 范围 PN-EN 15934:2013-02 Metoda A","technique_zh":"重量法","test_object_zh":"污泥"},{"_id":"6a82ca6d884ede9a1b2c2d7c","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,10 – 5,00) %"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość fosforu ogólnego\nZakres (0,10 – 5,00) %\nMetoda spektrofotometryczna","reference":"PN-EN 14672:2006 | PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN 14672:2006","PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość fosforu ogólnego\nZakres (0,10 – 5,00) %\nMetoda spektrofotometryczna PN-EN 14672:2006 | PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010 Osady sciekowe Zawartosc fosforu ogolnego\nZakres (0,10 – 5,00) %\nMetoda spektrofotometryczna PN-EN 14672:2006 | PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total phosphorus content","parameters_en":[{"name":"Range","range":"(0,10 – 5,00) %"}],"search_en":"Sewage sludge Total phosphorus content Spectrophotometric method Laboratory Range PN-EN 14672:2006 | PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Sewage sludge","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,10 – 5,00) %"}],"search_zh":"污泥 总磷含量 分光光度法 实验室 范围 PN-EN 14672:2006 | PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"污泥","methodology_zh":"总磷含量"},{"_id":"6a82ca6d884ede9a1b2c2d7d","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"pH w H2O","parameters":[{"name":"Zakres","range":"4,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH w H2O\nZakres 4,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe pH w H2O\nZakres 4,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Osady sciekowe pH w H2O\nZakres 4,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["water"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"pH in H2O","parameters_en":[{"name":"Range","range":"4,0 – 12,0"}],"search_en":"Sewage sludge pH in H2O Potentiometric method Laboratory Range PN-EN ISO 10390:2022-09","technique_en":"Potentiometric method","test_object_en":"Sewage sludge","lab_section_zh":"实验室","methodology_zh":"水中 pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 12,0"}],"search_zh":"污泥 水中 pH 值 电位法 实验室 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法","test_object_zh":"污泥"},{"_id":"6a82ca6d884ede9a1b2c2d7e","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Obecność bakterii z rodzaju Salmonella","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność bakterii z rodzaju Salmonella\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"PB/NW/M/11 wydanie 2 z dnia 02.12.2019 r.","norm_bases":["PB/NW/M/11 wydanie 2 z dnia 02.12.2019 r."],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Obecność bakterii z rodzaju Salmonella\nMetoda hodowlana z potwierdzeniem biochemicznym PB/NW/M/11 wydanie 2 z dnia 02.12.2019 r. Osady sciekowe Obecnosc bakterii z rodzaju Salmonella\nMetoda hodowlana z potwierdzeniem biochemicznym PB/NW/M/11 wydanie 2 z dnia 02.12.2019 r.","categories":["microbiology","water"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Presence of bacteria of the genus Salmonella","search_en":"Sewage sludge Presence of bacteria of the genus Salmonella Culture method with biochemical confirmation Laboratory PB/NW/M/11 wydanie 2 z dnia 02.12.2019 r.","technique_en":"Culture method with biochemical confirmation","test_object_en":"Sewage sludge","lab_section_zh":"实验室","search_zh":"污泥 沙门氏菌属细菌的检出 培养法结合生化确认 实验室 PB/NW/M/11 wydanie 2 z dnia 02.12.2019 r.","technique_zh":"培养法结合生化确认","test_object_zh":"污泥","methodology_zh":"沙门氏菌属细菌的检出"},{"_id":"6a82ca6d884ede9a1b2c2d7f","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Obecność i liczba żywych jaj pasożytów jelitowych Ascaris sp., Trichuris sp., Toxocara sp.(ATT)","parameters":[{"name":"Zakres","range":"od 1 w kg s.m."}],"technique":"Metoda flotacji i mikroskopowa","techniques":["Metoda flotacji i mikroskopowa"],"computed":[],"activity":"Obecność i liczba żywych jaj pasożytów jelitowych Ascaris sp., Trichuris sp., Toxocara sp.(ATT)\nZakres od 1 w kg s.m.\nMetoda flotacji i mikroskopowa","reference":"PN-Z-19005:2018-10","norm_bases":["PN-Z-19005:2018-10"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Obecność i liczba żywych jaj pasożytów jelitowych Ascaris sp., Trichuris sp., Toxocara sp.(ATT)\nZakres od 1 w kg s.m.\nMetoda flotacji i mikroskopowa PN-Z-19005:2018-10 Osady sciekowe Obecnosc i liczba zywych jaj pasozytow jelitowych Ascaris sp., Trichuris sp., Toxocara sp.(ATT)\nZakres od 1 w kg s.m.\nMetoda flotacji i mikroskopowa PN-Z-19005:2018-10","categories":["water"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","parameters_en":[{"name":"Range","range":"od 1 w kg s.m."}],"search_en":"Sewage sludge Laboratory Range PN-Z-19005:2018-10","test_object_en":"Sewage sludge","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"od 1 w kg s.m."}],"search_zh":"污泥 实验室 范围 PN-Z-19005:2018-10","test_object_zh":"污泥"},{"_id":"6a82ca6d884ede9a1b2c2d80","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Obecność i liczba żywych jaj pasożytów jelitowych Ascaris sp., Trichuris sp., Toxocara sp.(ATT)","parameters":[{"name":"Zakres","range":"od 1 w kg s.m."}],"technique":"Metoda flotacji i mikroskopowa","techniques":["Metoda flotacji i mikroskopowa"],"computed":[],"activity":"Obecność i liczba żywych jaj pasożytów jelitowych Ascaris sp., Trichuris sp., Toxocara sp.(ATT)\nZakres od 1 w kg s.m.\nMetoda flotacji i mikroskopowa","reference":"PB/NW/M/12 wydanie 3 z dnia 02.12.2019 r.","norm_bases":["PB/NW/M/12 wydanie 3 z dnia 02.12.2019 r."],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Obecność i liczba żywych jaj pasożytów jelitowych Ascaris sp., Trichuris sp., Toxocara sp.(ATT)\nZakres od 1 w kg s.m.\nMetoda flotacji i mikroskopowa PB/NW/M/12 wydanie 3 z dnia 02.12.2019 r. Osady sciekowe Obecnosc i liczba zywych jaj pasozytow jelitowych Ascaris sp., Trichuris sp., Toxocara sp.(ATT)\nZakres od 1 w kg s.m.\nMetoda flotacji i mikroskopowa PB/NW/M/12 wydanie 3 z dnia 02.12.2019 r.","categories":["water"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","parameters_en":[{"name":"Range","range":"od 1 w kg s.m."}],"search_en":"Sewage sludge Laboratory Range PB/NW/M/12 wydanie 3 z dnia 02.12.2019 r.","test_object_en":"Sewage sludge","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"od 1 w kg s.m."}],"search_zh":"污泥 实验室 范围 PB/NW/M/12 wydanie 3 z dnia 02.12.2019 r.","test_object_zh":"污泥"},{"_id":"6a82ca6d884ede9a1b2c2d81","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Pobieranie próbek do badań chemicznych, fizycznych i mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych, fizycznych i mikrobiologicznych","reference":"PN-EN ISO 5667-13:2011","norm_bases":["PN-EN ISO 5667-13:2011"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Pobieranie próbek do badań chemicznych, fizycznych i mikrobiologicznych PN-EN ISO 5667-13:2011 Osady sciekowe Pobieranie probek do badan chemicznych, fizycznych i mikrobiologicznych PN-EN ISO 5667-13:2011","categories":["water","microbiology"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sampling for chemical, physical and microbiological testing","search_en":"Sewage sludge Sampling for chemical, physical and microbiological testing Laboratory PN-EN ISO 5667-13:2011","test_object_en":"Sewage sludge","lab_section_zh":"实验室","search_zh":"污泥 用于化学、物理与微生物检验的采样 实验室 PN-EN ISO 5667-13:2011","test_object_zh":"污泥","methodology_zh":"用于化学、物理与微生物检验的采样"},{"_id":"6a82ca6d884ede9a1b2c2d82","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Odpady O) kod: 19 08 01, 19 08 02, 19 08 05, 19 12 09, 20 03 06","methodology":"Sucha masa","parameters":[{"name":"Zakres","range":"(1,0 – 99,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha masa\nZakres (1,0 – 99,0) %\nMetoda wagowa","reference":"PN-EN 15934:2013-02 Metoda A","norm_bases":["PN-EN 15934:2013-02 Metoda A"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":"O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady O) kod: 19 08 01, 19 08 02, 19 08 05, 19 12 09, 20 03 06 Sucha masa\nZakres (1,0 – 99,0) %\nMetoda wagowa PN-EN 15934:2013-02 Metoda A Odpady O) kod: 19 08 01, 19 08 02, 19 08 05, 19 12 09, 20 03 06 Sucha masa\nZakres (1,0 – 99,0) %\nMetoda wagowa PN-EN 15934:2013-02 Metoda A","categories":["environment"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Dry matter","parameters_en":[{"name":"Range","range":"(1,0 – 99,0) %"}],"search_en":"Dry matter Gravimetric method Laboratory Range PN-EN 15934:2013-02 Metoda A","technique_en":"Gravimetric method","lab_section_zh":"实验室","methodology_zh":"干物质","parameters_zh":[{"name":"范围","range":"(1,0 – 99,0) %"}],"search_zh":"干物质 重量法 实验室 范围 PN-EN 15934:2013-02 Metoda A","technique_zh":"重量法"},{"_id":"6a82ca6d884ede9a1b2c2d83","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Odpady O) kod: 19 08 01, 19 08 02, 19 08 05, 19 12 09, 20 03 06","methodology":"Strata przy prażeniu (LOI)","parameters":[{"name":"Zakres","range":"(1,0 – 99,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Strata przy prażeniu (LOI)\nZakres (1,0 – 99,0) %\nMetoda wagowa","reference":"PN-EN 15935:2022-01 p. 7.3","norm_bases":["PN-EN 15935:2022-01 p. 7.3"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":"O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady O) kod: 19 08 01, 19 08 02, 19 08 05, 19 12 09, 20 03 06 Strata przy prażeniu (LOI)\nZakres (1,0 – 99,0) %\nMetoda wagowa PN-EN 15935:2022-01 p. 7.3 Odpady O) kod: 19 08 01, 19 08 02, 19 08 05, 19 12 09, 20 03 06 Strata przy prazeniu (LOI)\nZakres (1,0 – 99,0) %\nMetoda wagowa PN-EN 15935:2022-01 p. 7.3","categories":["environment"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","parameters_en":[{"name":"Range","range":"(1,0 – 99,0) %"}],"search_en":"Gravimetric method Laboratory Range PN-EN 15935:2022-01 p. 7.3","technique_en":"Gravimetric method","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(1,0 – 99,0) %"}],"search_zh":"重量法 实验室 范围 PN-EN 15935:2022-01 p. 7.3","technique_zh":"重量法"},{"_id":"6a82ca6d884ede9a1b2c2d84","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Odpady O) kod: 19 08 01, 19 08 02, 19 08 05, 19 12 09, 20 03 06","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PP/NW/1 wydanie 3 z dnia 02.12.2019 r.","norm_bases":["PP/NW/1 wydanie 3 z dnia 02.12.2019 r."],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":"O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady O) kod: 19 08 01, 19 08 02, 19 08 05, 19 12 09, 20 03 06 Pobieranie próbek do badań chemicznych i fizycznych PP/NW/1 wydanie 3 z dnia 02.12.2019 r. Odpady O) kod: 19 08 01, 19 08 02, 19 08 05, 19 12 09, 20 03 06 Pobieranie probek do badan chemicznych i fizycznych PP/NW/1 wydanie 3 z dnia 02.12.2019 r.","categories":["environment"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sampling for chemical and physical testing","search_en":"Sampling for chemical and physical testing Laboratory PP/NW/1 wydanie 3 z dnia 02.12.2019 r.","lab_section_zh":"实验室","methodology_zh":"化学与物理检测用样品采集","search_zh":"化学与物理检测用样品采集 实验室 PP/NW/1 wydanie 3 z dnia 02.12.2019 r."},{"_id":"6a82ca6d884ede9a1b2c2d85","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Węgle aktywne","methodology":"Liczba adsorpcji jodu","parameters":[{"name":"Zakres","range":"(450 – 1500) mg/g"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Liczba adsorpcji jodu\nZakres (450 – 1500) mg/g\nMetoda miareczkowa","reference":"PN-83/C-97555.04","norm_bases":["PN-83/C-97555.04"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Węgle aktywne Liczba adsorpcji jodu\nZakres (450 – 1500) mg/g\nMetoda miareczkowa PN-83/C-97555.04 Wegle aktywne Liczba adsorpcji jodu\nZakres (450 – 1500) mg/g\nMetoda miareczkowa PN-83/C-97555.04","categories":["other"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","parameters_en":[{"name":"Range","range":"(450 – 1500) mg/g"}],"search_en":"Activated carbons Titrimetric method Laboratory Range PN-83/C-97555.04","technique_en":"Titrimetric method","test_object_en":"Activated carbons","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(450 – 1500) mg/g"}],"search_zh":"活性炭 滴定法 实验室 范围 PN-83/C-97555.04","technique_zh":"滴定法","test_object_zh":"活性炭"},{"_id":"6a82ca6d884ede9a1b2c2d86","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Węgle aktywne","methodology":"Gęstość nasypowa","parameters":[{"name":"Zakres","range":"(400 – 1000) g/dm3"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Gęstość nasypowa\nZakres (400 – 1000) g/dm3\nMetoda wagowa","reference":"PN-90/C-97554 p. 5.4.2","norm_bases":["PN-90/C-97554 p. 5.4.2"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Węgle aktywne Gęstość nasypowa\nZakres (400 – 1000) g/dm3\nMetoda wagowa PN-90/C-97554 p. 5.4.2 Wegle aktywne Gestosc nasypowa\nZakres (400 – 1000) g/dm3\nMetoda wagowa PN-90/C-97554 p. 5.4.2","categories":["other"],"row_index":73,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Bulk density","parameters_en":[{"name":"Range","range":"(400 – 1000) g/dm3"}],"search_en":"Activated carbons Bulk density Gravimetric method Laboratory Range PN-90/C-97554 p. 5.4.2","technique_en":"Gravimetric method","test_object_en":"Activated carbons","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(400 – 1000) g/dm3"}],"search_zh":"活性炭 堆积密度 重量法 实验室 范围 PN-90/C-97554 p. 5.4.2","technique_zh":"重量法","methodology_zh":"堆积密度","test_object_zh":"活性炭"},{"_id":"6a82ca6d884ede9a1b2c2d87","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Węgle aktywne","methodology":"Zawartość popiołu","parameters":[{"name":"Zakres","range":"(0,30 – 30,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość popiołu\nZakres (0,30 – 30,0) %\nMetoda wagowa","reference":"PN-EN 12902:2005 p. 6.2","norm_bases":["PN-EN 12902:2005 p. 6.2"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Węgle aktywne Zawartość popiołu\nZakres (0,30 – 30,0) %\nMetoda wagowa PN-EN 12902:2005 p. 6.2 Wegle aktywne Zawartosc popiolu\nZakres (0,30 – 30,0) %\nMetoda wagowa PN-EN 12902:2005 p. 6.2","categories":["other"],"row_index":74,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Ash content","parameters_en":[{"name":"Range","range":"(0,30 – 30,0) %"}],"search_en":"Activated carbons Ash content Gravimetric method Laboratory Range PN-EN 12902:2005 p. 6.2","technique_en":"Gravimetric method","test_object_en":"Activated carbons","lab_section_zh":"实验室","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(0,30 – 30,0) %"}],"search_zh":"活性炭 灰分含量 重量法 实验室 范围 PN-EN 12902:2005 p. 6.2","technique_zh":"重量法","test_object_zh":"活性炭"},{"_id":"6a82ca6d884ede9a1b2c2d88","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Węgle aktywne","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(1,5 – 60,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wody\nZakres (1,5 – 60,0) %\nMetoda wagowa","reference":"PN-EN 12902:2005 p. 6.5","norm_bases":["PN-EN 12902:2005 p. 6.5"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Węgle aktywne Zawartość wody\nZakres (1,5 – 60,0) %\nMetoda wagowa PN-EN 12902:2005 p. 6.5 Wegle aktywne Zawartosc wody\nZakres (1,5 – 60,0) %\nMetoda wagowa PN-EN 12902:2005 p. 6.5","categories":["water"],"row_index":75,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Water content","parameters_en":[{"name":"Range","range":"(1,5 – 60,0) %"}],"search_en":"Activated carbons Water content Gravimetric method Laboratory Range PN-EN 12902:2005 p. 6.5","technique_en":"Gravimetric method","test_object_en":"Activated carbons","lab_section_zh":"实验室","methodology_zh":"水分含量","parameters_zh":[{"name":"范围","range":"(1,5 – 60,0) %"}],"search_zh":"活性炭 水分含量 重量法 实验室 范围 PN-EN 12902:2005 p. 6.5","technique_zh":"重量法","test_object_zh":"活性炭"},{"_id":"6a82ca6d884ede9a1b2c2d89","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Węgle aktywne","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(1,5 – 60,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wody\nZakres (1,5 – 60,0) %\nMetoda wagowa","reference":"PN-84/C-97555/09 p. 2","norm_bases":["PN-84/C-97555/09 p. 2"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Węgle aktywne Zawartość wody\nZakres (1,5 – 60,0) %\nMetoda wagowa PN-84/C-97555/09 p. 2 Wegle aktywne Zawartosc wody\nZakres (1,5 – 60,0) %\nMetoda wagowa PN-84/C-97555/09 p. 2","categories":["water"],"row_index":76,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Water content","parameters_en":[{"name":"Range","range":"(1,5 – 60,0) %"}],"search_en":"Activated carbons Water content Gravimetric method Laboratory Range PN-84/C-97555/09 p. 2","technique_en":"Gravimetric method","test_object_en":"Activated carbons","lab_section_zh":"实验室","methodology_zh":"水分含量","parameters_zh":[{"name":"范围","range":"(1,5 – 60,0) %"}],"search_zh":"活性炭 水分含量 重量法 实验室 范围 PN-84/C-97555/09 p. 2","technique_zh":"重量法","test_object_zh":"活性炭"},{"_id":"6a82ca6d884ede9a1b2c2d8a","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Węgle aktywne","methodology":"Wytrzymałość mechaniczna","parameters":[{"name":"Zakres","range":"(1,0 – 100) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Wytrzymałość mechaniczna\nZakres (1,0 – 100) %\nMetoda wagowa","reference":"PN-EN 12915-1:2009 p. 8.2.4","norm_bases":["PN-EN 12915-1:2009 p. 8.2.4"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Węgle aktywne Wytrzymałość mechaniczna\nZakres (1,0 – 100) %\nMetoda wagowa PN-EN 12915-1:2009 p. 8.2.4 Wegle aktywne Wytrzymalosc mechaniczna\nZakres (1,0 – 100) %\nMetoda wagowa PN-EN 12915-1:2009 p. 8.2.4","categories":["other"],"row_index":77,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Mechanical strength","parameters_en":[{"name":"Range","range":"(1,0 – 100) %"}],"search_en":"Activated carbons Mechanical strength Gravimetric method Laboratory Range PN-EN 12915-1:2009 p. 8.2.4","technique_en":"Gravimetric method","test_object_en":"Activated carbons","lab_section_zh":"实验室","methodology_zh":"机械强度","parameters_zh":[{"name":"范围","range":"(1,0 – 100) %"}],"search_zh":"活性炭 机械强度 重量法 实验室 范围 PN-EN 12915-1:2009 p. 8.2.4","technique_zh":"重量法","test_object_zh":"活性炭"},{"_id":"6a82ca6d884ede9a1b2c2d8b","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Węgle aktywne","methodology":"Analiza sitowa","parameters":[{"name":"Zakres","range":"(0,4 – 99,9) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Analiza sitowa\nZakres (0,4 – 99,9) %\nMetoda wagowa","reference":"PN-ISO 2591-1:2000","norm_bases":["PN-ISO 2591-1:2000"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Węgle aktywne Analiza sitowa\nZakres (0,4 – 99,9) %\nMetoda wagowa PN-ISO 2591-1:2000 Wegle aktywne Analiza sitowa\nZakres (0,4 – 99,9) %\nMetoda wagowa PN-ISO 2591-1:2000","categories":["other"],"row_index":78,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sieve analysis","parameters_en":[{"name":"Range","range":"(0,4 – 99,9) %"}],"search_en":"Activated carbons Sieve analysis Gravimetric method Laboratory Range PN-ISO 2591-1:2000","technique_en":"Gravimetric method","test_object_en":"Activated carbons","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,4 – 99,9) %"}],"search_zh":"活性炭 筛分分析 重量法 实验室 范围 PN-ISO 2591-1:2000","technique_zh":"重量法","test_object_zh":"活性炭","methodology_zh":"筛分分析"},{"_id":"6a82ca6d884ede9a1b2c2d8c","lab_id":"69ad52a3de79e566650fb618","country":"PL","accr_number":"AB 1188","accr_body":"PCA","test_object":"Węgle aktywne","methodology":"Liczba jodowa","parameters":[{"name":"Zakres","range":"(600 – 1400) mg/g"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Liczba jodowa\nZakres (600 – 1400) mg/g\nMetoda miareczkowa","reference":"PN-EN 12902:2005 p. 6.10","norm_bases":["PN-EN 12902:2005 p. 6.10"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Węgle aktywne Liczba jodowa\nZakres (600 – 1400) mg/g\nMetoda miareczkowa PN-EN 12902:2005 p. 6.10 Wegle aktywne Liczba jodowa\nZakres (600 – 1400) mg/g\nMetoda miareczkowa PN-EN 12902:2005 p. 6.10","categories":["other"],"row_index":79,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Iodine value","parameters_en":[{"name":"Range","range":"(600 – 1400) mg/g"}],"search_en":"Activated carbons Iodine value Titrimetric method Laboratory Range PN-EN 12902:2005 p. 6.10","technique_en":"Titrimetric method","test_object_en":"Activated carbons","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(600 – 1400) mg/g"}],"search_zh":"活性炭 碘值 滴定法 实验室 范围 PN-EN 12902:2005 p. 6.10","technique_zh":"滴定法","test_object_zh":"活性炭","methodology_zh":"碘值"}],"has_pdf":true}