🇵🇱 „HUTA POKÓJ” S.A. PL
Materials & polymers
„HUTA POKÓJ” S.A. is a laboratory accredited by PCA under number AB 1187 (Ruda Śląska, Poland). Its accreditation scope covers 14 test methods in the following areas: Materials & polymers. Test objects include: Structural products and materials - plates - strips - open and clos…, Steel structural products and materials. Most frequently used techniques: Method – Vickers, Spark excitation atomic emission spectrometry.
At a glance
- Accreditation number: PCA AB 1187
- Methods in scope: 14
- Types of test objects: 2
- Techniques used: 2
- City: Ruda Śląska, Poland
- Accreditation number
- AB 1187
- Accreditation body
- PCA
- Address
- DZIAŁ KONTROLI JAKOŚCI I LABORATORIÓW, ul. Piotra Niedurnego 56, 41-709 Ruda Śląska
- City
- Ruda Śląska, Poland
What this laboratory tests (2)
- Structural products and materials - plates - strips - open and closed sections — 10 methods
- Steel structural products and materials — 4 methods
Analytical techniques used (2)
- Method – Vickers — 1 method
- Spark excitation atomic emission spectrometry — 1 method
Laboratory sections (2)
- Quality Control and Laboratories Department; Metals Testing Laboratory — 10 methods
- Quality Control and Laboratories Department; Chemical Testing Laboratory — 4 methods
Laboratory locations
- DZIAŁ KONTROLI JAKOŚCI I LABORATORIÓW — ul. Piotra Niedurnego 56
- Laboratorium Badań Chemicznych — ul. Piotra Niedurnego 56, 41-709 Ruda Śląska
- Laboratorium Badań Metali — ul. Piotra Niedurnego 56, 41-709 Ruda Śląska
- Dział Kontroli Jakości i Laboratoriów; Laboratorium Badań Chemicznych —
- Dział Kontroli Jakości i Laboratoriów; Laboratorium Badań Metali —
Accreditation scope — test methods (14)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Quality Control and Laboratories Department; Chemical Testing Laboratory | |||||
| 1 | Steel structural products and materials | Content of elements: C, Mn, Si, P, | QPL-DKJ-16 wydanie nr 8 z dnia 20.01.2023 r. | ||
| 2 | Steel structural products and materials | S, Cu, Cr, Ni, Mo, Nb, N, Al., W, Pb, B, | QPL-DKJ-16 wydanie nr 8 z dnia 20.01.2023 r. | ||
| 3 | Steel structural products and materials | Sn, Ti, V | QPL-DKJ-16 wydanie nr 8 z dnia 20.01.2023 r. | ||
| 4 | Steel structural products and materials | C, Mn, Si, P, S, Cu, Cr, Ni, Mo, Nb, N, Al, W, Pb, B, Sn, Ti, V (0,011 – 1,65) % (0,016 - 4,6) % (0,009 - 2,8) % (0,007 - 0,1) % (0,002 - 0,07) % (0,010 – 1,94) % (0,008 - 20,7) % (0,010 - 24,7) % (0,002 – 3,5) % (0,002 - 0,1) % (0,003 - 0,25) % (0,002 - 1,5) % (0,048 – 5,55) % (0,0015 - 0,25) % (0,0008 - 0,008) % (0,004 - 0,11) % (0,002 - 0,2) % (0,002 - 0,7) % | Spark excitation atomic emission spectrometry | QPL-DKJ-16 wydanie nr 8 z dnia 20.01.2023 r. | |
| Quality Control and Laboratories Department; Metals Testing Laboratory | |||||
| 5 | Structural products and materials - plates - strips - open and closed sections | Impact energy Range KV2, KU2 |
PN-EN ISO 148-1:2017-02 | ||
| 6 | Structural products and materials - plates - strips - open and closed sections | Test temperature: room (23 ± 5) °C reduced: do -40 °C |
PN-EN ISO 148-1:2017-02 | ||
| 7 | Structural products and materials - plates - strips - open and closed sections | Initial Hammer energy Initial Hammer energy 450 J |
PN-EN ISO 148-1:2017-02 | ||
| 8 | Structural products and materials - plates - strips - open and closed sections | Impact test by the method of | PN-EN ISO 148-1:2017-02 | ||
| 9 | Structural products and materials - plates - strips - open and closed sections | Charpy | PN-EN ISO 148-1:2017-02 | ||
| 10 | Structural products and materials - plates - strips - open and closed sections | Mechanical properties: distinct yield strength Re proof strength, plastic extension Rp tensile strength Rm percentage elongation after fracture A percentage reduction of area Z force F do 500 kN Tensile test at room temperature Mechanical properties: distinct yield strength Re proof strength, plastic extension Rp tensile strength Rm percentage elongation after fracture A percentage reduction of area Z force F do 500 kN |
PN EN ISO 6892 1:2020-05 Metoda B | ||
| 11 | Structural products and materials - plates - strips - open and closed sections | Tensile test at room temperature | PN EN ISO 6892 1:2020-05 Metoda B | ||
| 12 | Structural products and materials - plates - strips - open and closed sections | HV hardness Range HV 10 |
Method – Vickers | PN-EN ISO 6507-1:2024-04 | |
| 13 | Structural products and materials - plates - strips - open and closed sections | Susceptibility to plastic deformation | PN-EN ISO 7438:2021-04 | ||
| 14 | Structural products and materials - plates - strips - open and closed sections | Technological bend test | PN-EN ISO 7438:2021-04 | ||
Reference standards (5)
PN EN ISO 6892 1:2020-05 Metoda B
PN-EN ISO 148-1:2017-02
PN-EN ISO 6507-1:2024-04
PN-EN ISO 7438:2021-04
QPL-DKJ-16 wydanie nr 8 z dnia 20.01.2023 r.