{"lab":{"_id":"69ad52a3de79e566650fb616","accr_number":"AB 1187","country":"PL","accr_body":"PCA","address":"DZIAŁ KONTROLI JAKOŚCI I LABORATORIÓW, ul. Piotra Niedurnego 56, 41-709 Ruda Śląska","categories":["materials"],"city":"Ruda Śląska","imported_at":"2026-03-08T10:42:43.265Z","methods_count":14,"name":"„HUTA POKÓJ” S.A.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1187.pdf"],"scope_summary":"","search_text":"„huta pokój” s.a. dział kontroli jakości i laboratoriów, ul. piotra niedurnego 56, 41-709 ruda śląska materials other","status":"active","updated_at":"2026-03-08T14:50:22.237Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T07:57:59.671Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201187,podmiot.html","parse_date":"2026-08-13T07:57:59.671Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"C/8","pl":"Badania chemiczne wyrobów i materiałów konstrukcyjnych","en":"Chemical tests of construction products and materials"},{"codes":"J/8","pl":"Badania mechaniczne wyrobów i materiałów konstrukcyjnych","en":"Mechanical tests of construction products and materials"}],"issue":{"no":"17","date":"05.05.2026"},"map_coord":[50.292145,18.879004],"map_geo":"nominatim-street","lab_locations":[{"name":"DZIAŁ KONTROLI JAKOŚCI I LABORATORIÓW","address":"ul. Piotra Niedurnego 56","city":null,"postal":null},{"name":"Laboratorium Badań Chemicznych","address":"ul. Piotra Niedurnego 56, 41-709 Ruda Śląska","city":"Ruda Śląska","postal":"41-709"},{"name":"Laboratorium Badań Metali","address":"ul. Piotra Niedurnego 56, 41-709 Ruda Śląska","city":"Ruda Śląska","postal":"41-709"},{"name":"Dział Kontroli Jakości i Laboratoriów; Laboratorium Badań Chemicznych","address":null,"city":null,"postal":null},{"name":"Dział Kontroli Jakości i Laboratoriów; Laboratorium Badań Metali","address":null,"city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka5","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/4d4e168c425874b6acbfba03820f91cb/AB%201187.pdf","has_en":true,"category_counts":{"materials":14},"category_scores":{"materials":14},"has_zh":true,"lab_locations_zh":[{"name":"DZIAŁ KONTROLI JAKOŚCI I LABORATORIÓW","address":"ul. Piotra Niedurnego 56","city":null,"postal":null},{"name":"Laboratorium Badań Chemicznych","address":"ul. Piotra Niedurnego 56, 41-709 Ruda Śląska","city":"Ruda Śląska","postal":"41-709"},{"name":"Laboratorium Badań Metali","address":"ul. Piotra Niedurnego 56, 41-709 Ruda Śląska","city":"Ruda Śląska","postal":"41-709"},{"name":"质量控制与实验室部；化学检验实验室","address":null,"city":null,"postal":null},{"name":"质量控制与实验室部；金属检验实验室","address":null,"city":null,"postal":null}]},"methods":[{"_id":"6a7d79070636ba417e41a598","lab_id":"69ad52a3de79e566650fb616","country":"PL","accr_number":"AB 1187","accr_body":"PCA","test_object":"Stalowe wyroby i materiały konstrukcyjne","methodology":"Zawartość pierwiastków: C, Mn, Si, P,","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość pierwiastków: C, Mn, Si, P,","reference":"QPL-DKJ-16 wydanie nr 8 z dnia 20.01.2023 r.","norm_bases":["QPL-DKJ-16 wydanie nr 8 z dnia 20.01.2023 r."],"lab_section":"Dział Kontroli Jakości i Laboratoriów; Laboratorium Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Stalowe wyroby i materiały konstrukcyjne Zawartość pierwiastków: C, Mn, Si, P, QPL-DKJ-16 wydanie nr 8 z dnia 20.01.2023 r. Stalowe wyroby i materialy konstrukcyjne Zawartosc pierwiastkow: C, Mn, Si, P, QPL-DKJ-16 wydanie nr 8 z dnia 20.01.2023 r.","categories":["materials"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Quality Control and Laboratories Department; Chemical Testing Laboratory","methodology_en":"Content of elements: C, Mn, Si, P,","search_en":"Steel structural products and materials Content of elements: C, Mn, Si, P, Quality Control and Laboratories Department; Chemical Testing Laboratory QPL-DKJ-16 wydanie nr 8 z dnia 20.01.2023 r.","test_object_en":"Steel structural products and materials","lab_section_zh":"质量控制与实验室部；化学检验实验室","search_zh":"钢制品与结构材料 质量控制与实验室部；化学检验实验室 QPL-DKJ-16 wydanie nr 8 z dnia 20.01.2023 r.","test_object_zh":"钢制品与结构材料"},{"_id":"6a7d79070636ba417e41a599","lab_id":"69ad52a3de79e566650fb616","country":"PL","accr_number":"AB 1187","accr_body":"PCA","test_object":"Stalowe wyroby i materiały konstrukcyjne","methodology":"S, Cu, Cr, Ni, Mo, Nb, N, Al., W, Pb, B,","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"S, Cu, Cr, Ni, Mo, Nb, N, Al., W, Pb, B,","reference":"QPL-DKJ-16 wydanie nr 8 z dnia 20.01.2023 r.","norm_bases":["QPL-DKJ-16 wydanie nr 8 z dnia 20.01.2023 r."],"lab_section":"Dział Kontroli Jakości i Laboratoriów; Laboratorium Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Stalowe wyroby i materiały konstrukcyjne S, Cu, Cr, Ni, Mo, Nb, N, Al., W, Pb, B, QPL-DKJ-16 wydanie nr 8 z dnia 20.01.2023 r. Stalowe wyroby i materialy konstrukcyjne S, Cu, Cr, Ni, Mo, Nb, N, Al., W, Pb, B, QPL-DKJ-16 wydanie nr 8 z dnia 20.01.2023 r.","categories":["materials"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Quality Control and Laboratories Department; Chemical Testing Laboratory","methodology_en":"S, Cu, Cr, Ni, Mo, Nb, N, Al., W, Pb, B,","search_en":"Steel structural products and materials S, Cu, Cr, Ni, Mo, Nb, N, Al., W, Pb, B, Quality Control and Laboratories Department; Chemical Testing Laboratory QPL-DKJ-16 wydanie nr 8 z dnia 20.01.2023 r.","test_object_en":"Steel structural products and materials","lab_section_zh":"质量控制与实验室部；化学检验实验室","search_zh":"钢制品与结构材料 质量控制与实验室部；化学检验实验室 QPL-DKJ-16 wydanie nr 8 z dnia 20.01.2023 r.","test_object_zh":"钢制品与结构材料"},{"_id":"6a7d79070636ba417e41a59a","lab_id":"69ad52a3de79e566650fb616","country":"PL","accr_number":"AB 1187","accr_body":"PCA","test_object":"Stalowe wyroby i materiały konstrukcyjne","methodology":"Sn, Ti, V","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Sn, Ti, V","reference":"QPL-DKJ-16 wydanie nr 8 z dnia 20.01.2023 r.","norm_bases":["QPL-DKJ-16 wydanie nr 8 z dnia 20.01.2023 r."],"lab_section":"Dział Kontroli Jakości i Laboratoriów; Laboratorium Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Stalowe wyroby i materiały konstrukcyjne Sn, Ti, V QPL-DKJ-16 wydanie nr 8 z dnia 20.01.2023 r. Stalowe wyroby i materialy konstrukcyjne Sn, Ti, V QPL-DKJ-16 wydanie nr 8 z dnia 20.01.2023 r.","categories":["materials"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Quality Control and Laboratories Department; Chemical Testing Laboratory","methodology_en":"Sn, Ti, V","search_en":"Steel structural products and materials Sn, Ti, V Quality Control and Laboratories Department; Chemical Testing Laboratory QPL-DKJ-16 wydanie nr 8 z dnia 20.01.2023 r.","test_object_en":"Steel structural products and materials","lab_section_zh":"质量控制与实验室部；化学检验实验室","search_zh":"钢制品与结构材料 质量控制与实验室部；化学检验实验室 QPL-DKJ-16 wydanie nr 8 z dnia 20.01.2023 r.","test_object_zh":"钢制品与结构材料"},{"_id":"6a7d79070636ba417e41a59b","lab_id":"69ad52a3de79e566650fb616","country":"PL","accr_number":"AB 1187","accr_body":"PCA","test_object":"Stalowe wyroby i materiały konstrukcyjne","methodology":"C, Mn, Si, P, S, Cu, Cr, Ni, Mo, Nb, N, Al, W, Pb, B, Sn, Ti, V (0,011 – 1,65) % (0,016 - 4,6) % (0,009 - 2,8) % (0,007 - 0,1) % (0,002 - 0,07) % (0,010 – 1,94) % (0,008 - 20,7) % (0,010 - 24,7) % (0,002 – 3,5) % (0,002 - 0,1) % (0,003 - 0,25) % (0,002 - 1,5) % (0,048 – 5,55) % (0,0015 - 0,25) % (0,0008 - 0,008) % (0,004 - 0,11) % (0,002 - 0,2) % (0,002 - 0,7) %","parameters":[],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem iskrowym","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem iskrowym"],"computed":[],"activity":"C, Mn, Si, P, S, Cu, Cr, Ni, Mo, Nb, N, Al, W, Pb, B, Sn, Ti, V (0,011 – 1,65) % (0,016 - 4,6) % (0,009 - 2,8) % (0,007 - 0,1) % (0,002 - 0,07) % (0,010 – 1,94) % (0,008 - 20,7) % (0,010 - 24,7) % (0,002 – 3,5) % (0,002 - 0,1) % (0,003 - 0,25) % (0,002 - 1,5) % (0,048 – 5,55) % (0,0015 - 0,25) % (0,0008 - 0,008) % (0,004 - 0,11) % (0,002 - 0,2) % (0,002 - 0,7) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem iskrowym","reference":"QPL-DKJ-16 wydanie nr 8 z dnia 20.01.2023 r.","norm_bases":["QPL-DKJ-16 wydanie nr 8 z dnia 20.01.2023 r."],"lab_section":"Dział Kontroli Jakości i Laboratoriów; Laboratorium Badań Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Stalowe wyroby i materiały konstrukcyjne C, Mn, Si, P, S, Cu, Cr, Ni, Mo, Nb, N, Al, W, Pb, B, Sn, Ti, V (0,011 – 1,65) % (0,016 - 4,6) % (0,009 - 2,8) % (0,007 - 0,1) % (0,002 - 0,07) % (0,010 – 1,94) % (0,008 - 20,7) % (0,010 - 24,7) % (0,002 – 3,5) % (0,002 - 0,1) % (0,003 - 0,25) % (0,002 - 1,5) % (0,048 – 5,55) % (0,0015 - 0,25) % (0,0008 - 0,008) % (0,004 - 0,11) % (0,002 - 0,2) % (0,002 - 0,7) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem iskrowym QPL-DKJ-16 wydanie nr 8 z dnia 20.01.2023 r. Stalowe wyroby i materialy konstrukcyjne C, Mn, Si, P, S, Cu, Cr, Ni, Mo, Nb, N, Al, W, Pb, B, Sn, Ti, V (0,011 – 1,65) % (0,016 - 4,6) % (0,009 - 2,8) % (0,007 - 0,1) % (0,002 - 0,07) % (0,010 – 1,94) % (0,008 - 20,7) % (0,010 - 24,7) % (0,002 – 3,5) % (0,002 - 0,1) % (0,003 - 0,25) % (0,002 - 1,5) % (0,048 – 5,55) % (0,0015 - 0,25) % (0,0008 - 0,008) % (0,004 - 0,11) % (0,002 - 0,2) % (0,002 - 0,7) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem iskrowym QPL-DKJ-16 wydanie nr 8 z dnia 20.01.2023 r.","categories":["materials"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Quality Control and Laboratories Department; Chemical Testing Laboratory","methodology_en":"C, Mn, Si, P, S, Cu, Cr, Ni, Mo, Nb, N, Al, W, Pb, B, Sn, Ti, V (0,011 – 1,65) % (0,016 - 4,6) % (0,009 - 2,8) % (0,007 - 0,1) % (0,002 - 0,07) % (0,010 – 1,94) % (0,008 - 20,7) % (0,010 - 24,7) % (0,002 – 3,5) % (0,002 - 0,1) % (0,003 - 0,25) % (0,002 - 1,5) % (0,048 – 5,55) % (0,0015 - 0,25) % (0,0008 - 0,008) % (0,004 - 0,11) % (0,002 - 0,2) % (0,002 - 0,7) %","search_en":"Steel structural products and materials C, Mn, Si, P, S, Cu, Cr, Ni, Mo, Nb, N, Al, W, Pb, B, Sn, Ti, V (0,011 – 1,65) % (0,016 - 4,6) % (0,009 - 2,8) % (0,007 - 0,1) % (0,002 - 0,07) % (0,010 – 1,94) % (0,008 - 20,7) % (0,010 - 24,7) % (0,002 – 3,5) % (0,002 - 0,1) % (0,003 - 0,25) % (0,002 - 1,5) % (0,048 – 5,55) % (0,0015 - 0,25) % (0,0008 - 0,008) % (0,004 - 0,11) % (0,002 - 0,2) % (0,002 - 0,7) % Spark excitation atomic emission spectrometry Quality Control and Laboratories Department; Chemical Testing Laboratory QPL-DKJ-16 wydanie nr 8 z dnia 20.01.2023 r.","technique_en":"Spark excitation atomic emission spectrometry","test_object_en":"Steel structural products and materials","search_zh":"钢制品与结构材料 火花激发原子发射光谱法 质量控制与实验室部；化学检验实验室 QPL-DKJ-16 wydanie nr 8 z dnia 20.01.2023 r.","technique_zh":"火花激发原子发射光谱法","lab_section_zh":"质量控制与实验室部；化学检验实验室","test_object_zh":"钢制品与结构材料"},{"_id":"6a7d79070636ba417e41a59c","lab_id":"69ad52a3de79e566650fb616","country":"PL","accr_number":"AB 1187","accr_body":"PCA","test_object":"Wyroby i materiały konstrukcyjne - blachy - taśmy - kształtowniki otwarte i zamknięte","methodology":"Praca łamania","parameters":[{"name":"Zakres","range":"KV2, KU2"}],"technique":null,"techniques":[],"computed":[],"activity":"Praca łamania\nZakres KV2, KU2","reference":"PN-EN ISO 148-1:2017-02","norm_bases":["PN-EN ISO 148-1:2017-02"],"lab_section":"Dział Kontroli Jakości i Laboratoriów; Laboratorium Badań Metali","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby i materiały konstrukcyjne - blachy - taśmy - kształtowniki otwarte i zamknięte Praca łamania\nZakres KV2, KU2 PN-EN ISO 148-1:2017-02 Wyroby i materialy konstrukcyjne - blachy - tasmy - ksztaltowniki otwarte i zamkniete Praca lamania\nZakres KV2, KU2 PN-EN ISO 148-1:2017-02","categories":["materials"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Quality Control and Laboratories Department; Metals Testing Laboratory","methodology_en":"Impact energy","parameters_en":[{"name":"Range","range":"KV2, KU2"}],"search_en":"Structural products and materials - plates - strips - open and closed sections Impact energy Quality Control and Laboratories Department; Metals Testing Laboratory Range PN-EN ISO 148-1:2017-02","test_object_en":"Structural products and materials - plates - strips - open and closed sections","parameters_zh":[{"name":"范围","range":"KV2, KU2"}],"search_zh":"结构制品与材料 － 板材 － 带材 － 开口与闭口型材 断裂功 质量控制与实验室部；金属检验实验室 范围 PN-EN ISO 148-1:2017-02","methodology_zh":"断裂功","lab_section_zh":"质量控制与实验室部；金属检验实验室","test_object_zh":"结构制品与材料 － 板材 － 带材 － 开口与闭口型材"},{"_id":"6a7d79070636ba417e41a59d","lab_id":"69ad52a3de79e566650fb616","country":"PL","accr_number":"AB 1187","accr_body":"PCA","test_object":"Wyroby i materiały konstrukcyjne - blachy - taśmy - kształtowniki otwarte i zamknięte","methodology":"Temperatura badania:","parameters":[{"name":"pokojowa","range":"(23 ± 5) °C"},{"name":"obniżona:","range":"do -40 °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura badania:\nZakres:\npokojowa (23 ± 5) °C\nobniżona: do -40 °C","reference":"PN-EN ISO 148-1:2017-02","norm_bases":["PN-EN ISO 148-1:2017-02"],"lab_section":"Dział Kontroli Jakości i Laboratoriów; Laboratorium Badań Metali","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby i materiały konstrukcyjne - blachy - taśmy - kształtowniki otwarte i zamknięte Temperatura badania:\nZakres:\npokojowa (23 ± 5) °C\nobniżona: do -40 °C PN-EN ISO 148-1:2017-02 Wyroby i materialy konstrukcyjne - blachy - tasmy - ksztaltowniki otwarte i zamkniete Temperatura badania:\nZakres:\npokojowa (23 ± 5) °C\nobnizona: do -40 °C PN-EN ISO 148-1:2017-02","categories":["materials"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Quality Control and Laboratories Department; Metals Testing Laboratory","methodology_en":"Test temperature:","parameters_en":[{"name":"room","range":"(23 ± 5) °C"},{"name":"reduced:","range":"do -40 °C"}],"search_en":"Structural products and materials - plates - strips - open and closed sections Test temperature: Quality Control and Laboratories Department; Metals Testing Laboratory room reduced: PN-EN ISO 148-1:2017-02","test_object_en":"Structural products and materials - plates - strips - open and closed sections","methodology_zh":"试验温度：","search_zh":"结构制品与材料 － 板材 － 带材 － 开口与闭口型材 试验温度： 质量控制与实验室部；金属检验实验室 室温的 PN-EN ISO 148-1:2017-02","lab_section_zh":"质量控制与实验室部；金属检验实验室","parameters_zh":[{"name":"室温的","range":"(23 ± 5) °C"},{"name":"obniżona:","range":"do -40 °C"}],"test_object_zh":"结构制品与材料 － 板材 － 带材 － 开口与闭口型材"},{"_id":"6a7d79070636ba417e41a59e","lab_id":"69ad52a3de79e566650fb616","country":"PL","accr_number":"AB 1187","accr_body":"PCA","test_object":"Wyroby i materiały konstrukcyjne - blachy - taśmy - kształtowniki otwarte i zamknięte","methodology":"Początkowa Energia młota","parameters":[{"name":"Początkowa Energia młota","range":"450 J"}],"technique":null,"techniques":[],"computed":[],"activity":"Początkowa Energia młota\nZakres: 450 J","reference":"PN-EN ISO 148-1:2017-02","norm_bases":["PN-EN ISO 148-1:2017-02"],"lab_section":"Dział Kontroli Jakości i Laboratoriów; Laboratorium Badań Metali","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby i materiały konstrukcyjne - blachy - taśmy - kształtowniki otwarte i zamknięte Początkowa Energia młota\nZakres: 450 J PN-EN ISO 148-1:2017-02 Wyroby i materialy konstrukcyjne - blachy - tasmy - ksztaltowniki otwarte i zamkniete Poczatkowa Energia mlota\nZakres: 450 J PN-EN ISO 148-1:2017-02","categories":["materials"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Quality Control and Laboratories Department; Metals Testing Laboratory","methodology_en":"Initial Hammer energy","parameters_en":[{"name":"Initial Hammer energy","range":"450 J"}],"search_en":"Structural products and materials - plates - strips - open and closed sections Initial Hammer energy Quality Control and Laboratories Department; Metals Testing Laboratory Initial Hammer energy PN-EN ISO 148-1:2017-02","test_object_en":"Structural products and materials - plates - strips - open and closed sections","lab_section_zh":"质量控制与实验室部；金属检验实验室","search_zh":"结构制品与材料 － 板材 － 带材 － 开口与闭口型材 质量控制与实验室部；金属检验实验室 PN-EN ISO 148-1:2017-02","test_object_zh":"结构制品与材料 － 板材 － 带材 － 开口与闭口型材"},{"_id":"6a7d79070636ba417e41a59f","lab_id":"69ad52a3de79e566650fb616","country":"PL","accr_number":"AB 1187","accr_body":"PCA","test_object":"Wyroby i materiały konstrukcyjne - blachy - taśmy - kształtowniki otwarte i zamknięte","methodology":"Próba udarności sposobem","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Próba udarności sposobem","reference":"PN-EN ISO 148-1:2017-02","norm_bases":["PN-EN ISO 148-1:2017-02"],"lab_section":"Dział Kontroli Jakości i Laboratoriów; Laboratorium Badań Metali","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby i materiały konstrukcyjne - blachy - taśmy - kształtowniki otwarte i zamknięte Próba udarności sposobem PN-EN ISO 148-1:2017-02 Wyroby i materialy konstrukcyjne - blachy - tasmy - ksztaltowniki otwarte i zamkniete Proba udarnosci sposobem PN-EN ISO 148-1:2017-02","categories":["materials"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Quality Control and Laboratories Department; Metals Testing Laboratory","methodology_en":"Impact test by the method of","search_en":"Structural products and materials - plates - strips - open and closed sections Impact test by the method of Quality Control and Laboratories Department; Metals Testing Laboratory PN-EN ISO 148-1:2017-02","test_object_en":"Structural products and materials - plates - strips - open and closed sections","lab_section_zh":"质量控制与实验室部；金属检验实验室","search_zh":"结构制品与材料 － 板材 － 带材 － 开口与闭口型材 质量控制与实验室部；金属检验实验室 PN-EN ISO 148-1:2017-02","test_object_zh":"结构制品与材料 － 板材 － 带材 － 开口与闭口型材"},{"_id":"6a7d79070636ba417e41a5a0","lab_id":"69ad52a3de79e566650fb616","country":"PL","accr_number":"AB 1187","accr_body":"PCA","test_object":"Wyroby i materiały konstrukcyjne - blachy - taśmy - kształtowniki otwarte i zamknięte","methodology":"Charpy’ego","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Charpy’ego","reference":"PN-EN ISO 148-1:2017-02","norm_bases":["PN-EN ISO 148-1:2017-02"],"lab_section":"Dział Kontroli Jakości i Laboratoriów; Laboratorium Badań Metali","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby i materiały konstrukcyjne - blachy - taśmy - kształtowniki otwarte i zamknięte Charpy’ego PN-EN ISO 148-1:2017-02 Wyroby i materialy konstrukcyjne - blachy - tasmy - ksztaltowniki otwarte i zamkniete Charpy’ego PN-EN ISO 148-1:2017-02","categories":["materials"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Quality Control and Laboratories Department; Metals Testing Laboratory","methodology_en":"Charpy","search_en":"Structural products and materials - plates - strips - open and closed sections Charpy Quality Control and Laboratories Department; Metals Testing Laboratory PN-EN ISO 148-1:2017-02","test_object_en":"Structural products and materials - plates - strips - open and closed sections","lab_section_zh":"质量控制与实验室部；金属检验实验室","search_zh":"结构制品与材料 － 板材 － 带材 － 开口与闭口型材 质量控制与实验室部；金属检验实验室 PN-EN ISO 148-1:2017-02","test_object_zh":"结构制品与材料 － 板材 － 带材 － 开口与闭口型材"},{"_id":"6a7d79070636ba417e41a5a1","lab_id":"69ad52a3de79e566650fb616","country":"PL","accr_number":"AB 1187","accr_body":"PCA","test_object":"Wyroby i materiały konstrukcyjne - blachy - taśmy - kształtowniki otwarte i zamknięte","methodology":"Własności mechaniczne:","parameters":[{"name":"wyraźna granica plastyczności Re"},{"name":"umowna granica plastyczności Rp"},{"name":"wytrzymałość na rozciąganie Rm"},{"name":"wydłużenie procentowe po zerwaniu A"},{"name":"przewężenie procentowe Z"},{"name":"siła F","range":"do 500 kN"},{"name":"Próba rozciągania w temperaturze pokojowej Własności mechaniczne:"},{"name":"wyraźna granica plastyczności Re"},{"name":"umowna granica plastyczności Rp"},{"name":"wytrzymałość na rozciąganie Rm"},{"name":"wydłużenie procentowe po zerwaniu A"},{"name":"przewężenie procentowe Z"},{"name":"siła F","range":"do 500 kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Własności mechaniczne:\nZakres:\nwyraźna granica plastyczności Re\numowna granica plastyczności Rp\nwytrzymałość na rozciąganie Rm\nwydłużenie procentowe po zerwaniu A\nprzewężenie procentowe Z\nsiła F do 500 kN\nPróba rozciągania w temperaturze pokojowej Własności mechaniczne:\nwyraźna granica plastyczności Re\numowna granica plastyczności Rp\nwytrzymałość na rozciąganie Rm\nwydłużenie procentowe po zerwaniu A\nprzewężenie procentowe Z\nsiła F do 500 kN","reference":"PN EN ISO 6892 1:2020-05 Metoda B","norm_bases":["PN EN ISO 6892 1:2020-05 Metoda B"],"lab_section":"Dział Kontroli Jakości i Laboratoriów; Laboratorium Badań Metali","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby i materiały konstrukcyjne - blachy - taśmy - kształtowniki otwarte i zamknięte Własności mechaniczne:\nZakres:\nwyraźna granica plastyczności Re\numowna granica plastyczności Rp\nwytrzymałość na rozciąganie Rm\nwydłużenie procentowe po zerwaniu A\nprzewężenie procentowe Z\nsiła F do 500 kN\nPróba rozciągania w temperaturze pokojowej Własności mechaniczne:\nwyraźna granica plastyczności Re\numowna granica plastyczności Rp\nwytrzymałość na rozciąganie Rm\nwydłużenie procentowe po zerwaniu A\nprzewężenie procentowe Z\nsiła F do 500 kN PN EN ISO 6892 1:2020-05 Metoda B Wyroby i materialy konstrukcyjne - blachy - tasmy - ksztaltowniki otwarte i zamkniete Wlasnosci mechaniczne:\nZakres:\nwyrazna granica plastycznosci Re\numowna granica plastycznosci Rp\nwytrzymalosc na rozciaganie Rm\nwydluzenie procentowe po zerwaniu A\nprzewezenie procentowe Z\nsila F do 500 kN\nProba rozciagania w temperaturze pokojowej Wlasnosci mechaniczne:\nwyrazna granica plastycznosci Re\numowna granica plastycznosci Rp\nwytrzymalosc na rozciaganie Rm\nwydluzenie procentowe po zerwaniu A\nprzewezenie procentowe Z\nsila F do 500 kN PN EN ISO 6892 1:2020-05 Metoda B","categories":["materials"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Quality Control and Laboratories Department; Metals Testing Laboratory","methodology_en":"Mechanical properties:","parameters_en":[{"name":"distinct yield strength Re"},{"name":"proof strength, plastic extension Rp"},{"name":"tensile strength Rm"},{"name":"percentage elongation after fracture A"},{"name":"percentage reduction of area Z"},{"name":"force F","range":"do 500 kN"},{"name":"Tensile test at room temperature Mechanical properties:"},{"name":"distinct yield strength Re"},{"name":"proof strength, plastic extension Rp"},{"name":"tensile strength Rm"},{"name":"percentage elongation after fracture A"},{"name":"percentage reduction of area Z"},{"name":"force F","range":"do 500 kN"}],"search_en":"Structural products and materials - plates - strips - open and closed sections Mechanical properties: Quality Control and Laboratories Department; Metals Testing Laboratory distinct yield strength Re proof strength, plastic extension Rp tensile strength Rm percentage elongation after fracture A percentage reduction of area Z force F Tensile test at room temperature Mechanical properties: distinct yield strength Re proof strength, plastic extension Rp tensile strength Rm percentage elongation after fracture A percentage reduction of area Z force F PN EN ISO 6892 1:2020-05 Metoda B","test_object_en":"Structural products and materials - plates - strips - open and closed sections","methodology_zh":"力学性能：","parameters_zh":[{"name":"明显屈服强度 Re"},{"name":"规定塑性延伸强度 Rp"},{"name":"抗拉强度 Rm"},{"name":"断后伸长率 A"},{"name":"przewężenie procentowe Z"},{"name":"力 F","range":"do 500 kN"},{"name":"Próba rozciągania w temperaturze pokojowej Własności mechaniczne:"},{"name":"明显屈服强度 Re"},{"name":"规定塑性延伸强度 Rp"},{"name":"抗拉强度 Rm"},{"name":"断后伸长率 A"},{"name":"przewężenie procentowe Z"},{"name":"力 F","range":"do 500 kN"}],"search_zh":"结构制品与材料 － 板材 － 带材 － 开口与闭口型材 力学性能： 质量控制与实验室部；金属检验实验室 明显屈服强度 Re 规定塑性延伸强度 Rp 抗拉强度 Rm 断后伸长率 A 力 F 明显屈服强度 Re 规定塑性延伸强度 Rp 抗拉强度 Rm 断后伸长率 A 力 F PN EN ISO 6892 1:2020-05 Metoda B","lab_section_zh":"质量控制与实验室部；金属检验实验室","test_object_zh":"结构制品与材料 － 板材 － 带材 － 开口与闭口型材"},{"_id":"6a7d79070636ba417e41a5a2","lab_id":"69ad52a3de79e566650fb616","country":"PL","accr_number":"AB 1187","accr_body":"PCA","test_object":"Wyroby i materiały konstrukcyjne - blachy - taśmy - kształtowniki otwarte i zamknięte","methodology":"Próba rozciągania w temperaturze pokojowej","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Próba rozciągania w temperaturze pokojowej","reference":"PN EN ISO 6892 1:2020-05 Metoda B","norm_bases":["PN EN ISO 6892 1:2020-05 Metoda B"],"lab_section":"Dział Kontroli Jakości i Laboratoriów; Laboratorium Badań Metali","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby i materiały konstrukcyjne - blachy - taśmy - kształtowniki otwarte i zamknięte Próba rozciągania w temperaturze pokojowej PN EN ISO 6892 1:2020-05 Metoda B Wyroby i materialy konstrukcyjne - blachy - tasmy - ksztaltowniki otwarte i zamkniete Proba rozciagania w temperaturze pokojowej PN EN ISO 6892 1:2020-05 Metoda B","categories":["materials"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Quality Control and Laboratories Department; Metals Testing Laboratory","methodology_en":"Tensile test at room temperature","search_en":"Structural products and materials - plates - strips - open and closed sections Tensile test at room temperature Quality Control and Laboratories Department; Metals Testing Laboratory PN EN ISO 6892 1:2020-05 Metoda B","test_object_en":"Structural products and materials - plates - strips - open and closed sections","methodology_zh":"室温拉伸试验","search_zh":"结构制品与材料 － 板材 － 带材 － 开口与闭口型材 室温拉伸试验 质量控制与实验室部；金属检验实验室 PN EN ISO 6892 1:2020-05 Metoda B","lab_section_zh":"质量控制与实验室部；金属检验实验室","test_object_zh":"结构制品与材料 － 板材 － 带材 － 开口与闭口型材"},{"_id":"6a7d79070636ba417e41a5a3","lab_id":"69ad52a3de79e566650fb616","country":"PL","accr_number":"AB 1187","accr_body":"PCA","test_object":"Wyroby i materiały konstrukcyjne - blachy - taśmy - kształtowniki otwarte i zamknięte","methodology":"Twardość HV","parameters":[{"name":"Zakres","range":"HV 10"}],"technique":"Metoda – Vickersa","techniques":["Metoda – Vickersa"],"computed":[],"activity":"Twardość HV\nZakres HV 10\nMetoda – Vickersa","reference":"PN-EN ISO 6507-1:2024-04","norm_bases":["PN-EN ISO 6507-1:2024-04"],"lab_section":"Dział Kontroli Jakości i Laboratoriów; Laboratorium Badań Metali","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby i materiały konstrukcyjne - blachy - taśmy - kształtowniki otwarte i zamknięte Twardość HV\nZakres HV 10\nMetoda – Vickersa PN-EN ISO 6507-1:2024-04 Wyroby i materialy konstrukcyjne - blachy - tasmy - ksztaltowniki otwarte i zamkniete Twardosc HV\nZakres HV 10\nMetoda – Vickersa PN-EN ISO 6507-1:2024-04","categories":["materials"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Quality Control and Laboratories Department; Metals Testing Laboratory","methodology_en":"HV hardness","parameters_en":[{"name":"Range","range":"HV 10"}],"search_en":"Structural products and materials - plates - strips - open and closed sections HV hardness Method – Vickers Quality Control and Laboratories Department; Metals Testing Laboratory Range PN-EN ISO 6507-1:2024-04","technique_en":"Method – Vickers","test_object_en":"Structural products and materials - plates - strips - open and closed sections","parameters_zh":[{"name":"范围","range":"HV 10"}],"search_zh":"结构制品与材料 － 板材 － 带材 － 开口与闭口型材 维氏硬度 HV 质量控制与实验室部；金属检验实验室 范围 PN-EN ISO 6507-1:2024-04","methodology_zh":"维氏硬度 HV","lab_section_zh":"质量控制与实验室部；金属检验实验室","test_object_zh":"结构制品与材料 － 板材 － 带材 － 开口与闭口型材"},{"_id":"6a7d79070636ba417e41a5a4","lab_id":"69ad52a3de79e566650fb616","country":"PL","accr_number":"AB 1187","accr_body":"PCA","test_object":"Wyroby i materiały konstrukcyjne - blachy - taśmy - kształtowniki otwarte i zamknięte","methodology":"Podatność do odkształceń plastycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Podatność do odkształceń plastycznych","reference":"PN-EN ISO 7438:2021-04","norm_bases":["PN-EN ISO 7438:2021-04"],"lab_section":"Dział Kontroli Jakości i Laboratoriów; Laboratorium Badań Metali","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby i materiały konstrukcyjne - blachy - taśmy - kształtowniki otwarte i zamknięte Podatność do odkształceń plastycznych PN-EN ISO 7438:2021-04 Wyroby i materialy konstrukcyjne - blachy - tasmy - ksztaltowniki otwarte i zamkniete Podatnosc do odksztalcen plastycznych PN-EN ISO 7438:2021-04","categories":["materials"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Quality Control and Laboratories Department; Metals Testing Laboratory","methodology_en":"Susceptibility to plastic deformation","search_en":"Structural products and materials - plates - strips - open and closed sections Susceptibility to plastic deformation Quality Control and Laboratories Department; Metals Testing Laboratory PN-EN ISO 7438:2021-04","test_object_en":"Structural products and materials - plates - strips - open and closed sections","lab_section_zh":"质量控制与实验室部；金属检验实验室","methodology_zh":"塑性变形敏感性","search_zh":"结构制品与材料 － 板材 － 带材 － 开口与闭口型材 塑性变形敏感性 质量控制与实验室部；金属检验实验室 PN-EN ISO 7438:2021-04","test_object_zh":"结构制品与材料 － 板材 － 带材 － 开口与闭口型材"},{"_id":"6a7d79070636ba417e41a5a5","lab_id":"69ad52a3de79e566650fb616","country":"PL","accr_number":"AB 1187","accr_body":"PCA","test_object":"Wyroby i materiały konstrukcyjne - blachy - taśmy - kształtowniki otwarte i zamknięte","methodology":"Technologiczna próba zginania","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Technologiczna próba zginania","reference":"PN-EN ISO 7438:2021-04","norm_bases":["PN-EN ISO 7438:2021-04"],"lab_section":"Dział Kontroli Jakości i Laboratoriów; Laboratorium Badań Metali","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby i materiały konstrukcyjne - blachy - taśmy - kształtowniki otwarte i zamknięte Technologiczna próba zginania PN-EN ISO 7438:2021-04 Wyroby i materialy konstrukcyjne - blachy - tasmy - ksztaltowniki otwarte i zamkniete Technologiczna proba zginania PN-EN ISO 7438:2021-04","categories":["materials"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Quality Control and Laboratories Department; Metals Testing Laboratory","methodology_en":"Technological bend test","search_en":"Structural products and materials - plates - strips - open and closed sections Technological bend test Quality Control and Laboratories Department; Metals Testing Laboratory PN-EN ISO 7438:2021-04","test_object_en":"Structural products and materials - plates - strips - open and closed sections","lab_section_zh":"质量控制与实验室部；金属检验实验室","search_zh":"结构制品与材料 － 板材 － 带材 － 开口与闭口型材 质量控制与实验室部；金属检验实验室 PN-EN ISO 7438:2021-04","test_object_zh":"结构制品与材料 － 板材 － 带材 － 开口与闭口型材"}],"has_pdf":true}