ZAKŁAD WODOCIĄGÓW I KANALIZACJI W CIECHANOWIE Sp. z o.o. is a laboratory accredited by PCA under number AB 1175 (Ciechanów, Poland). Its accreditation scope covers 26 test methods in the following areas: Water & wastewater. Test objects include: Wastewater, Water, water intended for human consumption, wastewater, Water, water intended for human consumption, Water intended for human consumption. Most frequently used techniques: Spectrophotometric method, Electrochemical method, Gravimetric method.

At a glance

  • Accreditation number: PCA AB 1175
  • Methods in scope: 26
  • Types of test objects: 4
  • Techniques used: 12
  • City: Ciechanów, Poland
Accreditation number
AB 1175
Accreditation body
PCA
Address
ul. Gostkowska 81, 06-400 Ciechanów, LABORATORIUM, ul. Szczurzynek 1
City
Ciechanów, Poland

What this laboratory tests (4)

Analytical techniques used (12)

Laboratory locations

Accreditation scope — test methods (26)

No. Test object Methodology / Parameters Technique Reference document
Laboratory
1 Wastewater Sampling for chemical and physical testing
Temperature of wastewater/collected wastewater sample Range (1,0 – 50,0) oC
Manual method; Automatic method PN-ISO 5667-10:2021-11 | PN-77/C-04584
2 Wastewater Kjeldahl nitrogen concentration
Range (1,6 – 1000) mg/l
Titrimetric method PN-EN 25663:2001
3 Wastewater Total nitrogen concentration (calculated) PN-73/C-04576/14
4 Wastewater Biochemical oxygen demand
BOD5 Range (3 – 6000) mg/l O2
Electrochemical method PN-EN ISO 5815-1:2019-12
5 Wastewater Biochemical oxygen demand
BOD5 Range (1,0 – 6,0) mg/l O2
Electrochemical method PN-EN 1899-2:2002
6 Wastewater Chemical oxygen demand
COD-Cr Range (15,0 – 10 000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
7 Wastewater Total phosphorus concentration
Range (0,080 – 77,0) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 p.8 +Ap1:2010+Ap2:2010
8 Wastewater Total suspended solids (TSS)
Range (5,0 – 2000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
9 Wastewater Total iron concentration
Range (0,100 – 50,0) mg/l
Spectrophotometric method PN-ISO 6332:2001+Ap1:2016-06
10 Wastewater Concentration of substances extractable with petroleum ether
Range (5 – 1000) mg/l
Gravimetric method PN-86/C-04573/01
11 Wastewater Nitrite nitrogen concentration
Range (0,008 – 80,0) mg/l
Spectrophotometric method PN-EN 26777:1999
12 Water, water intended for human consumption, wastewater Electrical conductivity
Range (147 – 12800) μS/cm
Conductometric method PN-EN 27888:1999
13 Water, water intended for human consumption, wastewater pH
Range 4,0 – 10,0
Potentiometric method PN-EN ISO 10523:2012
14 Water, water intended for human consumption, wastewater Ammonium nitrogen concentration
Range (0,050 – 78,0) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
15 Water, water intended for human consumption, wastewater Nitrate nitrogen concentration
Range (0,11 – 23,0) mg/l
Spectrophotometric method PN-82/C-04576.08
16 Water, water intended for human consumption, wastewater Total nitrogen concentration
Range (1,0 – 150) mg/l
Spectrophotometric method PB-12.00 wydanie 2 z dnia 20.11.2019 r. | na podstawie testu kuwetowego Merck nr 1.00613.0001, 1.14763.0001
17 Water, water intended for human consumption, wastewater Sulfate concentration
Range (5,0 – 250) mg/l
Turbidimetric method PB-05.00 wydanie 3 z dnia 20.11.2019 r. | na podstawie testu kuwetowego Merck nr 1.14548.0001
18 Water, water intended for human consumption, wastewater Chloride concentration
Range (5,0 – 400) mg/l
Titrimetric method PN-ISO 9297:1994
19 Water, water intended for human consumption, wastewater Metal concentrations
Zinc (0,050 – 2,5) mg/l Copper (0,050 – 2,0) mg/l Lead (0,200 – 2,0) mg/l Cadmium (0,020 – 1,0) mg/l Nickel (0,100 – 3,0) mg/l
Flame atomic absorption spectrometry (FAAS) PN-ISO 8288:2002 metoda A
20 Water, water intended for human consumption, wastewater Anion concentrations
Chlorides (5,0 – 1000) mg/l Sulfates (5,0 – 1000) mg/l Nitrates (0,50 – 150) mg/l
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012
21 Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10
22 Water, water intended for human consumption Nitrite nitrogen concentration
Range (0,008 – 3,0) mg/l
Spectrophotometric method PN-EN 26777:1999
23 Water, water intended for human consumption Total iron concentration
Range (0,020 – 10,0) mg/l
Spectrophotometric method PN-ISO 6332:2001+Ap1:2016-06
24 Water, water intended for human consumption Colour
Range (5,0 – 70) mg/l Pt
Spectrophotometric method PN-EN ISO 7887:2012 metoda C +Ap1:2015-06
25 Water, water intended for human consumption Turbidity
Range (0,30 – 100) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
26 Water, water intended for human consumption Manganese concentration
Range (2,0 – 100) μg/l
Atomic absorption spectrometry with electrochemical atomization (ETAAS) PN-EN ISO 15586:2005

Reference standards (27)

PB-05.00 wydanie 3 z dnia 20.11.2019 r.
PB-12.00 wydanie 2 z dnia 20.11.2019 r.
PN-73/C-04576/14
PN-77/C-04584
PN-82/C-04576.08
PN-86/C-04573/01
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10304-1:2009+AC:2012
PN-EN ISO 10523:2012
PN-EN ISO 15586:2005
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6878:2006 p.8 +Ap1:2010+Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 metoda C +Ap1:2015-06
PN-ISO 15705:2005
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10
PN-ISO 6332:2001+Ap1:2016-06
PN-ISO 7150-1:2002
PN-ISO 8288:2002 metoda A
PN-ISO 9297:1994
na podstawie testu kuwetowego Merck nr 1.00613.0001, 1.14763.0001