🇵🇱 ZAKŁAD WODOCIĄGÓW I KANALIZACJI W CIECHANOWIE Sp. z o.o. PL
Water & wastewater
ZAKŁAD WODOCIĄGÓW I KANALIZACJI W CIECHANOWIE Sp. z o.o. is a laboratory accredited by PCA under number AB 1175 (Ciechanów, Poland). Its accreditation scope covers 26 test methods in the following areas: Water & wastewater. Test objects include: Wastewater, Water, water intended for human consumption, wastewater, Water, water intended for human consumption, Water intended for human consumption. Most frequently used techniques: Spectrophotometric method, Electrochemical method, Gravimetric method.
At a glance
- Accreditation number: PCA AB 1175
- Methods in scope: 26
- Types of test objects: 4
- Techniques used: 12
- City: Ciechanów, Poland
- Accreditation number
- AB 1175
- Accreditation body
- PCA
- Address
- ul. Gostkowska 81, 06-400 Ciechanów, LABORATORIUM, ul. Szczurzynek 1
- City
- Ciechanów, Poland
What this laboratory tests (4)
- Wastewater — 11 methods
- Water, water intended for human consumption, wastewater — 9 methods
- Water, water intended for human consumption — 5 methods
- Water intended for human consumption — 1 method
Analytical techniques used (12)
- Spectrophotometric method — 10 methods
- Electrochemical method — 2 methods
- Gravimetric method — 2 methods
- Titrimetric method — 2 methods
- Atomic absorption spectrometry with electrochemical atomization (ETAAS) — 1 method
- Conductometric method — 1 method
- Flame atomic absorption spectrometry (FAAS) — 1 method
- Ion chromatography with conductometric detection (IC-CD) — 1 method
- Manual method; Automatic method — 1 method
- Nephelometric method — 1 method
- Potentiometric method — 1 method
- Turbidimetric method — 1 method
Laboratory locations
- ZAKŁAD WODOCIĄGÓW I KANALIZACJI W CIECHANOWIE Sp. z o.o. — ul. Gostkowska 81
- Laboratorium —
Accreditation scope — test methods (26)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Laboratory | |||||
| 1 | Wastewater | Sampling for chemical and physical testing Temperature of wastewater/collected wastewater sample Range (1,0 – 50,0) oC |
Manual method; Automatic method | PN-ISO 5667-10:2021-11 | PN-77/C-04584 | |
| 2 | Wastewater | Kjeldahl nitrogen concentration Range (1,6 – 1000) mg/l |
Titrimetric method | PN-EN 25663:2001 | |
| 3 | Wastewater | Total nitrogen concentration (calculated) | PN-73/C-04576/14 | ||
| 4 | Wastewater | Biochemical oxygen demand BOD5 Range (3 – 6000) mg/l O2 |
Electrochemical method | PN-EN ISO 5815-1:2019-12 | |
| 5 | Wastewater | Biochemical oxygen demand BOD5 Range (1,0 – 6,0) mg/l O2 |
Electrochemical method | PN-EN 1899-2:2002 | |
| 6 | Wastewater | Chemical oxygen demand COD-Cr Range (15,0 – 10 000) mg/l O2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 7 | Wastewater | Total phosphorus concentration Range (0,080 – 77,0) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006 p.8 +Ap1:2010+Ap2:2010 | |
| 8 | Wastewater | Total suspended solids (TSS) Range (5,0 – 2000) mg/l |
Gravimetric method | PN-EN 872:2007+Ap1:2007 | |
| 9 | Wastewater | Total iron concentration Range (0,100 – 50,0) mg/l |
Spectrophotometric method | PN-ISO 6332:2001+Ap1:2016-06 | |
| 10 | Wastewater | Concentration of substances extractable with petroleum ether Range (5 – 1000) mg/l |
Gravimetric method | PN-86/C-04573/01 | |
| 11 | Wastewater | Nitrite nitrogen concentration Range (0,008 – 80,0) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 12 | Water, water intended for human consumption, wastewater | Electrical conductivity Range (147 – 12800) μS/cm |
Conductometric method | PN-EN 27888:1999 | |
| 13 | Water, water intended for human consumption, wastewater | pH Range 4,0 – 10,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 14 | Water, water intended for human consumption, wastewater | Ammonium nitrogen concentration Range (0,050 – 78,0) mg/l |
Spectrophotometric method | PN-ISO 7150-1:2002 | |
| 15 | Water, water intended for human consumption, wastewater | Nitrate nitrogen concentration Range (0,11 – 23,0) mg/l |
Spectrophotometric method | PN-82/C-04576.08 | |
| 16 | Water, water intended for human consumption, wastewater | Total nitrogen concentration Range (1,0 – 150) mg/l |
Spectrophotometric method | PB-12.00 wydanie 2 z dnia 20.11.2019 r. | na podstawie testu kuwetowego Merck nr 1.00613.0001, 1.14763.0001 | |
| 17 | Water, water intended for human consumption, wastewater | Sulfate concentration Range (5,0 – 250) mg/l |
Turbidimetric method | PB-05.00 wydanie 3 z dnia 20.11.2019 r. | na podstawie testu kuwetowego Merck nr 1.14548.0001 | |
| 18 | Water, water intended for human consumption, wastewater | Chloride concentration Range (5,0 – 400) mg/l |
Titrimetric method | PN-ISO 9297:1994 | |
| 19 | Water, water intended for human consumption, wastewater | Metal concentrations Zinc (0,050 – 2,5) mg/l Copper (0,050 – 2,0) mg/l Lead (0,200 – 2,0) mg/l Cadmium (0,020 – 1,0) mg/l Nickel (0,100 – 3,0) mg/l |
Flame atomic absorption spectrometry (FAAS) | PN-ISO 8288:2002 metoda A | |
| 20 | Water, water intended for human consumption, wastewater | Anion concentrations Chlorides (5,0 – 1000) mg/l Sulfates (5,0 – 1000) mg/l Nitrates (0,50 – 150) mg/l |
Ion chromatography with conductometric detection (IC-CD) | PN-EN ISO 10304-1:2009+AC:2012 | |
| 21 | Water intended for human consumption | Sampling for chemical and physical testing | PN-ISO 5667-5:2017-10 | ||
| 22 | Water, water intended for human consumption | Nitrite nitrogen concentration Range (0,008 – 3,0) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 23 | Water, water intended for human consumption | Total iron concentration Range (0,020 – 10,0) mg/l |
Spectrophotometric method | PN-ISO 6332:2001+Ap1:2016-06 | |
| 24 | Water, water intended for human consumption | Colour Range (5,0 – 70) mg/l Pt |
Spectrophotometric method | PN-EN ISO 7887:2012 metoda C +Ap1:2015-06 | |
| 25 | Water, water intended for human consumption | Turbidity Range (0,30 – 100) NTU |
Nephelometric method | PN-EN ISO 7027-1:2016-09 | |
| 26 | Water, water intended for human consumption | Manganese concentration Range (2,0 – 100) μg/l |
Atomic absorption spectrometry with electrochemical atomization (ETAAS) | PN-EN ISO 15586:2005 | |
Reference standards (27)
PB-05.00 wydanie 3 z dnia 20.11.2019 r.
PB-12.00 wydanie 2 z dnia 20.11.2019 r.
PN-73/C-04576/14
PN-77/C-04584
PN-82/C-04576.08
PN-86/C-04573/01
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10304-1:2009+AC:2012
PN-EN ISO 10523:2012
PN-EN ISO 15586:2005
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6878:2006 p.8 +Ap1:2010+Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 metoda C +Ap1:2015-06
PN-ISO 15705:2005
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10
PN-ISO 6332:2001+Ap1:2016-06
PN-ISO 7150-1:2002
PN-ISO 8288:2002 metoda A
PN-ISO 9297:1994
na podstawie testu kuwetowego Merck nr 1.00613.0001, 1.14763.0001
na podstawie testu kuwetowego Merck nr 1.14548.0001