{"lab":{"_id":"69ad52a3de79e566650fb602","accr_number":"AB 1175","country":"PL","accr_body":"PCA","address":"ul. Gostkowska 81, 06-400 Ciechanów, LABORATORIUM, ul. Szczurzynek 1","categories":["water"],"city":"Ciechanów","imported_at":"2026-03-08T10:42:43.265Z","methods_count":26,"name":"ZAKŁAD WODOCIĄGÓW I KANALIZACJI W CIECHANOWIE Sp. z o.o.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1175.pdf"],"scope_summary":"","search_text":"zakład wodociągów i kanalizacji w ciechanowie sp. z o.o. ul. gostkowska 81, 06-400 ciechanów, laboratorium, ul. szczurzynek 1 water other pharma electronics materials","status":"active","updated_at":"2026-03-08T14:50:21.139Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T07:57:31.676Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201175,podmiot.html","parse_date":"2026-08-13T07:57:31.676Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"C/29/P; C/30/P","pl":"Badania chemiczne i pobieranie próbek wody do spożycia przez ludzi, ścieków","en":"Chemical tests and sampling of drinking water, sewage"},{"codes":"C/28","pl":"Badania chemiczne wody","en":"Chemical tests of water"},{"codes":"N/29/P; N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody do spożycia przez ludzi, ścieków","en":"Tests of physical properties and sampling of drinking water, sewage"},{"codes":"N/28","pl":"Badania właściwości fizycznych wody","en":"Tests of physical properties of water"}],"issue":{"no":"16","date":"16.07.2026"},"map_coord":[52.896905,20.623407],"map_geo":"nominatim-street","lab_locations":[{"name":"ZAKŁAD WODOCIĄGÓW I KANALIZACJI W CIECHANOWIE Sp. z o.o.","address":"ul. Gostkowska 81","city":null,"postal":null},{"name":"Laboratorium","address":null,"city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/97e9581c5b59e0c0bfe537ec0e6b0f16/AB%201175.pdf","has_en":true,"category_counts":{"water":26,"materials":1},"category_scores":{"water":25.04,"materials":0.04},"has_zh":true,"lab_locations_zh":[{"name":"ZAKŁAD WODOCIĄGÓW I KANALIZACJI W CIECHANOWIE Sp. z o.o.","address":"ul. Gostkowska 81","city":null,"postal":null},{"name":"实验室","address":null,"city":null,"postal":null}]},"methods":[{"_id":"6a7d78eb0636ba417e41a421","lab_id":"69ad52a3de79e566650fb602","country":"PL","accr_number":"AB 1175","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[{"name":"Temperatura ścieków/pobranej próbki ścieków"},{"name":"Zakres","range":"(1,0 – 50,0) oC"}],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura ścieków/pobranej próbki ścieków\nZakres (1,0 – 50,0) oC\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11 | PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11","PN-77/C-04584"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura ścieków/pobranej próbki ścieków\nZakres (1,0 – 50,0) oC\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 | PN-77/C-04584 Scieki Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura sciekow/pobranej probki sciekow\nZakres (1,0 – 50,0) oC\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 | PN-77/C-04584","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sampling for chemical and physical testing","parameters_en":[{"name":"Temperature of wastewater/collected wastewater sample"},{"name":"Range","range":"(1,0 – 50,0) oC"}],"search_en":"Wastewater Sampling for chemical and physical testing Manual method; Automatic method Laboratory Temperature of wastewater/collected wastewater sample Range PN-ISO 5667-10:2021-11 | PN-77/C-04584","technique_en":"Manual method; Automatic method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"废水/所采废水样品的温度"},{"name":"范围","range":"(1,0 – 50,0) oC"}],"search_zh":"污水 化学与物理检测用样品采集 手动法；自动法 实验室 废水/所采废水样品的温度 范围 PN-ISO 5667-10:2021-11 | PN-77/C-04584","technique_zh":"手动法；自动法","test_object_zh":"污水"},{"_id":"6a7d78eb0636ba417e41a422","lab_id":"69ad52a3de79e566650fb602","country":"PL","accr_number":"AB 1175","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(1,6 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (1,6 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu Kjeldahla\nZakres (1,6 – 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Scieki Stezenie azotu Kjeldahla\nZakres (1,6 – 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(1,6 – 1000) mg/l"}],"search_en":"Wastewater Kjeldahl nitrogen concentration Titrimetric method Laboratory Range PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(1,6 – 1000) mg/l"}],"search_zh":"污水 凯氏氮浓度 滴定法 实验室 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a7d78eb0636ba417e41a423","lab_id":"69ad52a3de79e566650fb602","country":"PL","accr_number":"AB 1175","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu ogólnego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PN-73/C-04576/14","norm_bases":["PN-73/C-04576/14"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu ogólnego (z obliczeń) PN-73/C-04576/14 Scieki Stezenie azotu ogolnego (z obliczen) PN-73/C-04576/14","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total nitrogen concentration (calculated)","search_en":"Wastewater Total nitrogen concentration (calculated) Laboratory PN-73/C-04576/14","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"总氮浓度（计算值）","search_zh":"污水 总氮浓度（计算值） 实验室 PN-73/C-04576/14","test_object_zh":"污水"},{"_id":"6a7d78eb0636ba417e41a424","lab_id":"69ad52a3de79e566650fb602","country":"PL","accr_number":"AB 1175","accr_body":"PCA","test_object":"Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(3 – 6000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 6000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(3 – 6000) mg/l O2"}],"search_en":"Wastewater Biochemical oxygen demand Electrochemical method Laboratory BOD5 Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(3 – 6000) mg/l O2"}],"search_zh":"污水 生化需氧量 电化学法 实验室 BZT5（BOD5） 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"污水"},{"_id":"6a7d78eb0636ba417e41a425","lab_id":"69ad52a3de79e566650fb602","country":"PL","accr_number":"AB 1175","accr_body":"PCA","test_object":"Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(1,0 – 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1,0 – 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1,0 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1,0 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(1,0 – 6,0) mg/l O2"}],"search_en":"Wastewater Biochemical oxygen demand Electrochemical method Laboratory BOD5 Range PN-EN 1899-2:2002","technique_en":"Electrochemical method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(1,0 – 6,0) mg/l O2"}],"search_zh":"污水 生化需氧量 电化学法 实验室 BZT5（BOD5） 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"污水"},{"_id":"6a7d78eb0636ba417e41a426","lab_id":"69ad52a3de79e566650fb602","country":"PL","accr_number":"AB 1175","accr_body":"PCA","test_object":"Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu","parameters":[{"name":"ChZT-Cr"},{"name":"Zakres","range":"(15,0 – 10 000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (15,0 – 10 000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (15,0 – 10 000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Scieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (15,0 – 10 000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Chemical oxygen demand","parameters_en":[{"name":"COD-Cr"},{"name":"Range","range":"(15,0 – 10 000) mg/l O2"}],"search_en":"Wastewater Chemical oxygen demand Spectrophotometric method Laboratory COD-Cr Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"化学需氧量（COD-Cr）"},{"name":"范围","range":"(15,0 – 10 000) mg/l O2"}],"search_zh":"污水 化学需氧量（COD） 分光光度法 实验室 化学需氧量（COD-Cr） 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"化学需氧量（COD）"},{"_id":"6a7d78eb0636ba417e41a427","lab_id":"69ad52a3de79e566650fb602","country":"PL","accr_number":"AB 1175","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,080 – 77,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,080 – 77,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 p.8 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 p.8 +Ap1:2010+Ap2:2010"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie fosforu ogólnego\nZakres (0,080 – 77,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p.8 +Ap1:2010+Ap2:2010 Scieki Stezenie fosforu ogolnego\nZakres (0,080 – 77,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p.8 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,080 – 77,0) mg/l"}],"search_en":"Wastewater Total phosphorus concentration Spectrophotometric method Laboratory Range PN-EN ISO 6878:2006 p.8 +Ap1:2010+Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,080 – 77,0) mg/l"}],"search_zh":"污水 总磷浓度 分光光度法 实验室 范围 PN-EN ISO 6878:2006 p.8 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a7d78eb0636ba417e41a428","lab_id":"69ad52a3de79e566650fb602","country":"PL","accr_number":"AB 1175","accr_body":"PCA","test_object":"Ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(5,0 – 2000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (5,0 – 2000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Zawiesiny ogólne\nZakres (5,0 – 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Scieki Zawiesiny ogolne\nZakres (5,0 – 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(5,0 – 2000) mg/l"}],"search_en":"Wastewater Total suspended solids (TSS) Gravimetric method Laboratory Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(5,0 – 2000) mg/l"}],"search_zh":"污水 总悬浮物 重量法 实验室 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"污水"},{"_id":"6a7d78eb0636ba417e41a429","lab_id":"69ad52a3de79e566650fb602","country":"PL","accr_number":"AB 1175","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie żelaza ogólnego","parameters":[{"name":"Zakres","range":"(0,100 – 50,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza ogólnego\nZakres (0,100 – 50,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie żelaza ogólnego\nZakres (0,100 – 50,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 Scieki Stezenie zelaza ogolnego\nZakres (0,100 – 50,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total iron concentration","parameters_en":[{"name":"Range","range":"(0,100 – 50,0) mg/l"}],"search_en":"Wastewater Total iron concentration Spectrophotometric method Laboratory Range PN-ISO 6332:2001+Ap1:2016-06","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(0,100 – 50,0) mg/l"}],"search_zh":"污水 总铁浓度 分光光度法 实验室 范围 PN-ISO 6332:2001+Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a7d78eb0636ba417e41a42a","lab_id":"69ad52a3de79e566650fb602","country":"PL","accr_number":"AB 1175","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie substancji ekstrahujących się eterem naftowym","parameters":[{"name":"Zakres","range":"(5 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie substancji ekstrahujących się eterem naftowym\nZakres (5 – 1000) mg/l\nMetoda wagowa","reference":"PN-86/C-04573/01","norm_bases":["PN-86/C-04573/01"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie substancji ekstrahujących się eterem naftowym\nZakres (5 – 1000) mg/l\nMetoda wagowa PN-86/C-04573/01 Scieki Stezenie substancji ekstrahujacych sie eterem naftowym\nZakres (5 – 1000) mg/l\nMetoda wagowa PN-86/C-04573/01","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Concentration of substances extractable with petroleum ether","parameters_en":[{"name":"Range","range":"(5 – 1000) mg/l"}],"search_en":"Wastewater Concentration of substances extractable with petroleum ether Gravimetric method Laboratory Range PN-86/C-04573/01","technique_en":"Gravimetric method","test_object_en":"Wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(5 – 1000) mg/l"}],"search_zh":"污水 石油醚可萃取物浓度 重量法 实验室 范围 PN-86/C-04573/01","technique_zh":"重量法","test_object_zh":"污水","methodology_zh":"石油醚可萃取物浓度"},{"_id":"6a7d78eb0636ba417e41a42b","lab_id":"69ad52a3de79e566650fb602","country":"PL","accr_number":"AB 1175","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,008 – 80,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,008 – 80,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu azotynowego\nZakres (0,008 – 80,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Scieki Stezenie azotu azotynowego\nZakres (0,008 – 80,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,008 – 80,0) mg/l"}],"search_en":"Wastewater Nitrite nitrogen concentration Spectrophotometric method Laboratory Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,008 – 80,0) mg/l"}],"search_zh":"污水 亚硝态氮浓度 分光光度法 实验室 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a7d78eb0636ba417e41a42c","lab_id":"69ad52a3de79e566650fb602","country":"PL","accr_number":"AB 1175","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(147 – 12800) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (147 – 12800) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Przewodność elektryczna właściwa\nZakres (147 – 12800) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, woda do spozycia przez ludzi, scieki Przewodnosc elektryczna wlasciwa\nZakres (147 – 12800) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(147 – 12800) μS/cm"}],"search_en":"Water, water intended for human consumption, wastewater Electrical conductivity Conductometric method Laboratory Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, water intended for human consumption, wastewater","lab_section_zh":"实验室","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(147 – 12800) μS/cm"}],"search_zh":"水、生活饮用水、污水 电导率 电导法 实验室 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a7d78eb0636ba417e41a42d","lab_id":"69ad52a3de79e566650fb602","country":"PL","accr_number":"AB 1175","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, woda do spozycia przez ludzi, scieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"search_en":"Water, water intended for human consumption, wastewater pH Potentiometric method Laboratory Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, water intended for human consumption, wastewater","lab_section_zh":"实验室","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"水、生活饮用水、污水 pH 值 电位法 实验室 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a7d78eb0636ba417e41a42e","lab_id":"69ad52a3de79e566650fb602","country":"PL","accr_number":"AB 1175","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,050 – 78,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,050 – 78,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie azotu amonowego\nZakres (0,050 – 78,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, woda do spozycia przez ludzi, scieki Stezenie azotu amonowego\nZakres (0,050 – 78,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,050 – 78,0) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Ammonium nitrogen concentration Spectrophotometric method Laboratory Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption, wastewater","lab_section_zh":"实验室","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,050 – 78,0) mg/l"}],"search_zh":"水、生活饮用水、污水 氨氮浓度 分光光度法 实验室 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a7d78eb0636ba417e41a42f","lab_id":"69ad52a3de79e566650fb602","country":"PL","accr_number":"AB 1175","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,11 – 23,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (0,11 – 23,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie azotu azotanowego\nZakres (0,11 – 23,0) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08 Woda, woda do spozycia przez ludzi, scieki Stezenie azotu azotanowego\nZakres (0,11 – 23,0) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,11 – 23,0) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Nitrate nitrogen concentration Spectrophotometric method Laboratory Range PN-82/C-04576.08","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption, wastewater","lab_section_zh":"实验室","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,11 – 23,0) mg/l"}],"search_zh":"水、生活饮用水、污水 硝态氮浓度 分光光度法 实验室 范围 PN-82/C-04576.08","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a7d78eb0636ba417e41a430","lab_id":"69ad52a3de79e566650fb602","country":"PL","accr_number":"AB 1175","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie azotu ogólnego","parameters":[{"name":"Zakres","range":"(1,0 – 150) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu ogólnego\nZakres (1,0 – 150) mg/l\nMetoda spektrofotometryczna","reference":"PB-12.00 wydanie 2 z dnia 20.11.2019 r. | na podstawie testu kuwetowego Merck nr 1.00613.0001, 1.14763.0001","norm_bases":["PB-12.00 wydanie 2 z dnia 20.11.2019 r.","na podstawie testu kuwetowego Merck nr 1.00613.0001, 1.14763.0001"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie azotu ogólnego\nZakres (1,0 – 150) mg/l\nMetoda spektrofotometryczna PB-12.00 wydanie 2 z dnia 20.11.2019 r. | na podstawie testu kuwetowego Merck nr 1.00613.0001, 1.14763.0001 Woda, woda do spozycia przez ludzi, scieki Stezenie azotu ogolnego\nZakres (1,0 – 150) mg/l\nMetoda spektrofotometryczna PB-12.00 wydanie 2 z dnia 20.11.2019 r. | na podstawie testu kuwetowego Merck nr 1.00613.0001, 1.14763.0001","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total nitrogen concentration","parameters_en":[{"name":"Range","range":"(1,0 – 150) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Total nitrogen concentration Spectrophotometric method Laboratory Range PB-12.00 wydanie 2 z dnia 20.11.2019 r. | na podstawie testu kuwetowego Merck nr 1.00613.0001, 1.14763.0001","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption, wastewater","lab_section_zh":"实验室","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(1,0 – 150) mg/l"}],"search_zh":"水、生活饮用水、污水 总氮浓度 分光光度法 实验室 范围 PB-12.00 wydanie 2 z dnia 20.11.2019 r. | na podstawie testu kuwetowego Merck nr 1.00613.0001, 1.14763.0001","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a7d78eb0636ba417e41a431","lab_id":"69ad52a3de79e566650fb602","country":"PL","accr_number":"AB 1175","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(5,0 – 250) mg/l"}],"technique":"Metoda turbidymetryczna","techniques":["Metoda turbidymetryczna"],"computed":[],"activity":"Stężenie siarczanów\nZakres (5,0 – 250) mg/l\nMetoda turbidymetryczna","reference":"PB-05.00 wydanie 3 z dnia 20.11.2019 r. | na podstawie testu kuwetowego Merck nr 1.14548.0001","norm_bases":["PB-05.00 wydanie 3 z dnia 20.11.2019 r.","na podstawie testu kuwetowego Merck nr 1.14548.0001"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie siarczanów\nZakres (5,0 – 250) mg/l\nMetoda turbidymetryczna PB-05.00 wydanie 3 z dnia 20.11.2019 r. | na podstawie testu kuwetowego Merck nr 1.14548.0001 Woda, woda do spozycia przez ludzi, scieki Stezenie siarczanow\nZakres (5,0 – 250) mg/l\nMetoda turbidymetryczna PB-05.00 wydanie 3 z dnia 20.11.2019 r. | na podstawie testu kuwetowego Merck nr 1.14548.0001","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(5,0 – 250) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Sulfate concentration Turbidimetric method Laboratory Range PB-05.00 wydanie 3 z dnia 20.11.2019 r. | na podstawie testu kuwetowego Merck nr 1.14548.0001","technique_en":"Turbidimetric method","test_object_en":"Water, water intended for human consumption, wastewater","lab_section_zh":"实验室","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 250) mg/l"}],"search_zh":"水、生活饮用水、污水 硫酸盐浓度 浊度法 实验室 范围 PB-05.00 wydanie 3 z dnia 20.11.2019 r. | na podstawie testu kuwetowego Merck nr 1.14548.0001","test_object_zh":"水、生活饮用水、污水","technique_zh":"浊度法"},{"_id":"6a7d78eb0636ba417e41a432","lab_id":"69ad52a3de79e566650fb602","country":"PL","accr_number":"AB 1175","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,0 – 400) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,0 – 400) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie chlorków\nZakres (5,0 – 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, woda do spozycia przez ludzi, scieki Stezenie chlorkow\nZakres (5,0 – 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,0 – 400) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Chloride concentration Titrimetric method Laboratory Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water, water intended for human consumption, wastewater","lab_section_zh":"实验室","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 400) mg/l"}],"search_zh":"水、生活饮用水、污水 氯化物浓度 滴定法 实验室 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a7d78eb0636ba417e41a433","lab_id":"69ad52a3de79e566650fb602","country":"PL","accr_number":"AB 1175","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie metali","parameters":[{"name":"Cynk","range":"(0,050 – 2,5) mg/l"},{"name":"Miedź","range":"(0,050 – 2,0) mg/l"},{"name":"Ołów","range":"(0,200 – 2,0) mg/l"},{"name":"Kadm","range":"(0,020 – 1,0) mg/l"},{"name":"Nikiel","range":"(0,100 – 3,0) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie metali\nZakres:\nCynk (0,050 – 2,5) mg/l\nMiedź (0,050 – 2,0) mg/l\nOłów (0,200 – 2,0) mg/l\nKadm (0,020 – 1,0) mg/l\nNikiel (0,100 – 3,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 8288:2002 metoda A","norm_bases":["PN-ISO 8288:2002 metoda A"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie metali\nZakres:\nCynk (0,050 – 2,5) mg/l\nMiedź (0,050 – 2,0) mg/l\nOłów (0,200 – 2,0) mg/l\nKadm (0,020 – 1,0) mg/l\nNikiel (0,100 – 3,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 metoda A Woda, woda do spozycia przez ludzi, scieki Stezenie metali\nZakres:\nCynk (0,050 – 2,5) mg/l\nMiedz (0,050 – 2,0) mg/l\nOlow (0,200 – 2,0) mg/l\nKadm (0,020 – 1,0) mg/l\nNikiel (0,100 – 3,0) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 metoda A","categories":["materials","water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Metal concentrations","parameters_en":[{"name":"Zinc","range":"(0,050 – 2,5) mg/l"},{"name":"Copper","range":"(0,050 – 2,0) mg/l"},{"name":"Lead","range":"(0,200 – 2,0) mg/l"},{"name":"Cadmium","range":"(0,020 – 1,0) mg/l"},{"name":"Nickel","range":"(0,100 – 3,0) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Metal concentrations Flame atomic absorption spectrometry (FAAS) Laboratory Zinc Copper Lead Cadmium Nickel PN-ISO 8288:2002 metoda A","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Water, water intended for human consumption, wastewater","lab_section_zh":"实验室","methodology_zh":"金属浓度","parameters_zh":[{"name":"锌","range":"(0,050 – 2,5) mg/l"},{"name":"铜","range":"(0,050 – 2,0) mg/l"},{"name":"铅","range":"(0,200 – 2,0) mg/l"},{"name":"镉","range":"(0,020 – 1,0) mg/l"},{"name":"镍","range":"(0,100 – 3,0) mg/l"}],"search_zh":"水、生活饮用水、污水 金属浓度 火焰原子吸收光谱法（FAAS） 实验室 锌 铜 铅 镉 镍 PN-ISO 8288:2002 metoda A","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a7d78eb0636ba417e41a434","lab_id":"69ad52a3de79e566650fb602","country":"PL","accr_number":"AB 1175","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie anionów","parameters":[{"name":"Chlorki","range":"(5,0 – 1000) mg/l"},{"name":"Siarczany","range":"(5,0 – 1000) mg/l"},{"name":"Azotany","range":"(0,50 – 150) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów\nZakres:\nChlorki (5,0 – 1000) mg/l\nSiarczany (5,0 – 1000) mg/l\nAzotany (0,50 – 150) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie anionów\nZakres:\nChlorki (5,0 – 1000) mg/l\nSiarczany (5,0 – 1000) mg/l\nAzotany (0,50 – 150) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda, woda do spozycia przez ludzi, scieki Stezenie anionow\nZakres:\nChlorki (5,0 – 1000) mg/l\nSiarczany (5,0 – 1000) mg/l\nAzotany (0,50 – 150) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Anion concentrations","parameters_en":[{"name":"Chlorides","range":"(5,0 – 1000) mg/l"},{"name":"Sulfates","range":"(5,0 – 1000) mg/l"},{"name":"Nitrates","range":"(0,50 – 150) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Anion concentrations Ion chromatography with conductometric detection (IC-CD) Laboratory Chlorides Sulfates Nitrates PN-EN ISO 10304-1:2009+AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water, water intended for human consumption, wastewater","lab_section_zh":"实验室","methodology_zh":"阴离子浓度","parameters_zh":[{"name":"氯化物","range":"(5,0 – 1000) mg/l"},{"name":"硫酸盐","range":"(5,0 – 1000) mg/l"},{"name":"硝酸盐","range":"(0,50 – 150) mg/l"}],"search_zh":"水、生活饮用水、污水 阴离子浓度 离子色谱-电导检测法（IC-CD） 实验室 氯化物 硫酸盐 硝酸盐 PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a7d78eb0636ba417e41a435","lab_id":"69ad52a3de79e566650fb602","country":"PL","accr_number":"AB 1175","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-5:2017-10","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sampling for chemical and physical testing","search_en":"Water intended for human consumption Sampling for chemical and physical testing Laboratory PN-ISO 5667-5:2017-10","test_object_en":"Water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"化学与物理检测用样品采集","search_zh":"生活饮用水 化学与物理检测用样品采集 实验室 PN-ISO 5667-5:2017-10","test_object_zh":"生活饮用水"},{"_id":"6a7d78eb0636ba417e41a436","lab_id":"69ad52a3de79e566650fb602","country":"PL","accr_number":"AB 1175","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,008 – 3,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,008 – 3,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie azotu azotynowego\nZakres (0,008 – 3,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, woda do spozycia przez ludzi Stezenie azotu azotynowego\nZakres (0,008 – 3,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,008 – 3,0) mg/l"}],"search_en":"Water, water intended for human consumption Nitrite nitrogen concentration Spectrophotometric method Laboratory Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,008 – 3,0) mg/l"}],"search_zh":"水、生活饮用水 亚硝态氮浓度 分光光度法 实验室 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a7d78eb0636ba417e41a437","lab_id":"69ad52a3de79e566650fb602","country":"PL","accr_number":"AB 1175","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie żelaza ogólnego","parameters":[{"name":"Zakres","range":"(0,020 – 10,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza ogólnego\nZakres (0,020 – 10,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie żelaza ogólnego\nZakres (0,020 – 10,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 Woda, woda do spozycia przez ludzi Stezenie zelaza ogolnego\nZakres (0,020 – 10,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total iron concentration","parameters_en":[{"name":"Range","range":"(0,020 – 10,0) mg/l"}],"search_en":"Water, water intended for human consumption Total iron concentration Spectrophotometric method Laboratory Range PN-ISO 6332:2001+Ap1:2016-06","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(0,020 – 10,0) mg/l"}],"search_zh":"水、生活饮用水 总铁浓度 分光光度法 实验室 范围 PN-ISO 6332:2001+Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a7d78eb0636ba417e41a438","lab_id":"69ad52a3de79e566650fb602","country":"PL","accr_number":"AB 1175","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(5,0 – 70) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa\nZakres (5,0 – 70) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 metoda C +Ap1:2015-06","norm_bases":["PN-EN ISO 7887:2012 metoda C +Ap1:2015-06"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Barwa\nZakres (5,0 – 70) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 metoda C +Ap1:2015-06 Woda, woda do spozycia przez ludzi Barwa\nZakres (5,0 – 70) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 metoda C +Ap1:2015-06","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(5,0 – 70) mg/l Pt"}],"search_en":"Water, water intended for human consumption Colour Spectrophotometric method Laboratory Range PN-EN ISO 7887:2012 metoda C +Ap1:2015-06","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5,0 – 70) mg/l Pt"}],"search_zh":"水、生活饮用水 色度 分光光度法 实验室 范围 PN-EN ISO 7887:2012 metoda C +Ap1:2015-06","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a7d78eb0636ba417e41a439","lab_id":"69ad52a3de79e566650fb602","country":"PL","accr_number":"AB 1175","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,30 – 100) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,30 – 100) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Mętność\nZakres (0,30 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda, woda do spozycia przez ludzi Metnosc\nZakres (0,30 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,30 – 100) NTU"}],"search_en":"Water, water intended for human consumption Turbidity Nephelometric method Laboratory Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water, water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,30 – 100) NTU"}],"search_zh":"水、生活饮用水 浊度 浊度法（散射法） 实验室 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水、生活饮用水"},{"_id":"6a7d78eb0636ba417e41a43a","lab_id":"69ad52a3de79e566650fb602","country":"PL","accr_number":"AB 1175","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(2,0 – 100) μg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrochemiczną (ETAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrochemiczną (ETAAS)"],"computed":[],"activity":"Stężenie manganu\nZakres (2,0 – 100) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrochemiczną (ETAAS)","reference":"PN-EN ISO 15586:2005","norm_bases":["PN-EN ISO 15586:2005"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie manganu\nZakres (2,0 – 100) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrochemiczną (ETAAS) PN-EN ISO 15586:2005 Woda, woda do spozycia przez ludzi Stezenie manganu\nZakres (2,0 – 100) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacja elektrochemiczna (ETAAS) PN-EN ISO 15586:2005","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Manganese concentration","parameters_en":[{"name":"Range","range":"(2,0 – 100) μg/l"}],"search_en":"Water, water intended for human consumption Manganese concentration Atomic absorption spectrometry with electrochemical atomization (ETAAS) Laboratory Range PN-EN ISO 15586:2005","technique_en":"Atomic absorption spectrometry with electrochemical atomization (ETAAS)","test_object_en":"Water, water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(2,0 – 100) μg/l"}],"search_zh":"水、生活饮用水 锰浓度 电热原子化原子吸收光谱法（ETAAS） 实验室 范围 PN-EN ISO 15586:2005","test_object_zh":"水、生活饮用水","technique_zh":"电热原子化原子吸收光谱法（ETAAS）"}],"has_pdf":true}