🇵🇱 SYNTHOS DWORY 7 PL

PCA AB 1168 • Oświęcim, Poland • 38 methods

EnvironmentWater & wastewater

SYNTHOS DWORY 7 is a laboratory accredited by PCA under number AB 1168 (Oświęcim, Poland). Its accreditation scope covers 38 test methods in the following areas: Environment, Water & wastewater. Test objects include: Workplace environment − air, Water, wastewater, General environment - waste gas samples collected on sorbent tubes, Workplace environment − indoor electric lighting. Most frequently used techniques: Gas chromatography with flame ionization detection (GC-FID), Atomic absorption spectrometry with amalgamation technique, Direct measurement method.

At a glance

  • Accreditation number: PCA AB 1168
  • Methods in scope: 38
  • Types of test objects: 7
  • Techniques used: 10
  • City: Oświęcim, Poland
Accreditation number
AB 1168
Accreditation body
PCA
Address
spółka z ograniczoną odpowiedzialnością, LABORATORIUM ŚRODOWISKOWE, ul. Chemików 1, 32-600 Oświęcim
City
Oświęcim, Poland

What this laboratory tests (7)

Analytical techniques used (10)

Laboratory sections (4)

Laboratory locations

Accreditation scope — test methods (38)

No. Test object Methodology / Parameters Technique Reference document
Pracownia Stanowisk Pracy i Imisji − Chromatografia Gazowa
1 Workplace environment − air Benzene concentration
Range (0,07 – 5,56) mg/m3
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04016-10:2005
2 Workplace environment − air Toluene concentration
Range (1,39 – 400) mg/m3
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04115-01:1978
3 Workplace environment − air Ethylbenzene concentration
Range (1,39 – 800) mg/m3
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04081-01:1979
4 Workplace environment − air Styrene concentration
Range (1,39 – 200) mg/m3
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04152-02:1986
5 Workplace environment − air Stężenie akrylanu metylu
Range (1,39 – 178) mg/m3
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04113-05:1986
6 Workplace environment − air Stężenie akrylanu butylu
Range (1,39 – 178) mg/m3
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04113-06:1986
7 Workplace environment − air Stężenie metakrylanu metylu
Range (1,39 – 600) mg/m3
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04113-09:1992
8 Workplace environment − air Stężenie akrylonitrylu
Range (0,13 – 35,56) mg/m3
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04556:2024-09
9 Workplace environment − air Stężenie buta-1,3-dienu
Range (0,44 – 8,77) mg/m3
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04438:2021
10 Workplace environment − air Methanol concentration
Range (1,39 – 600) mg/m3
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04028-01:1981
11 Workplace environment − air Methyl acetate concentration
Range (1,39 – 1200) mg/m3
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04119-01:1978
12 Workplace environment − air Ethyl acetate concentration
Range (1,39 – 2936) mg/m3
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04119-01:1978
13 Workplace environment − air Vinyl acetate concentration
Range (1,39 – 178) mg/m3
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04178-02:1987
14 Workplace environment − air Ethanol concentration
Range (1,39 – 3800) mg/m3
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04023-02:1989
15 Workplace environment − air Pentane concentration
Range (55 – 6000) mg/m3
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04318:2005
16 Workplace environment − air Hexane concentration
Range (1,1 – 111,1) mg/m3
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04136-3:2003
17 General environment - waste gas samples collected on sorbent tubes Vinyl acetate content
Range (0,0125 − 0,4) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04178-02:1987
18 General environment - waste gas samples collected on sorbent tubes Styrene content
Range (0,0125 − 0,4) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04152-06:1993
19 General environment - waste gas samples collected on sorbent tubes Hexane content
Range (0,02 – 2,0) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04136-3:2003
Pracownia Stanowisk Pracy i Imisji
20 Workplace environment − air Sampling for the assessment of occupational exposure to:
dust agents − inhalable fraction − respirable fraction
Personal dosimetry method PN-Z-04008-7:2002+Az1:2004
21 Workplace environment − air Sampling for the assessment of occupational exposure to:
organic substances, including − inhalable fraction inorganic substances, including − inhalable fraction − respirable fraction metals and their compounds, including − inhalable fraction − respirable fraction
Personal dosimetry method; Stationary method PN-Z-04008-7:2002+Az1:2004
22 Workplace environment − air Exposure index (calculated) PN-Z-04008-7:2002+Az1:2004
23 Workplace environment − air Concentration of harmful dust agents – inhalable fraction
apatites and phosphorites petroleum bitumen portland cement titanium dioxide natural graphite synthetic graphite kaolin amorphous and synthetic silica wood dusts flour dusts dusts not classified according to toxicity organic dusts of animal and plant origin, excluding wood and flour dusts carbon black calcium sulfate (VI) (gypsum) talc coal (hard, brown) calcium magnesium carbonate (dolomite) silicon carbide, non-fibrous Range (0,13 – 20,42) mg/m3
Gravimetric method PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08
24 Workplace environment − air Concentration of harmful dust agents – respirable fraction
apatites and phosphorites portland cement natural graphite amorphous and synthetic silica organic dusts of animal and plant origin, excluding wood and flour dusts coal (hard, brown) Range (0,09 – 21,93) mg/m3
Gravimetric method PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08
25 Workplace environment − air Stężenie olejów mineralnych wysokorafinowanych z wyłączeniem cieczy obróbkowych – frakcja wdychalna
Range (0,5 – 10) mg/m3
Metoda spektrometrii w nadfiolecie PN-Z-04108-6:2006+Az1:2009
26 Workplace environment − air Ammonia concentration
Range (2 – 60) mg/m3
Spectrophotometric method PN-Z-04041:1971
27 Workplace environment − noise A-weighted equivalent sound level Maximum A-weighted sound level
Range (50 –139) dB C-weighted peak sound pressure level Range (50 – 140) dB
Direct measurement method PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 – punkt 10
28 Workplace environment − noise Noise exposure level referred to:
an 8-hour daily working time (calculated)
PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 – punkt 10
29 Workplace environment − indoor electric lighting Illuminance
Range (5 – 8600) lx
Direct measurement method PN-E-04040-03:1983 | INB 11 wyd.5 z dnia 11.12.2025r.
30 Workplace environment − indoor electric lighting Illuminance uniformity (calculated) PN-E-04040-03:1983 | INB 11 wyd.5 z dnia 11.12.2025r.
Pracownia AMA i ASA
31 Workplace environment − air Stężenie rtęci, par i jej związków nieorganicznych – w przeliczeniu na Hg
Range (0,002 − 0,085) mg/m3
Atomic absorption spectrometry with amalgamation technique PB-04/JŚ wydanie 12 z dnia 6.12.2022r.
32 Workplace environment − air Sodium hydroxide concentration
Range (0,024 − 2,0) mg/m3
Flame atomic absorption spectrometry (FAAS) PN-Z-04435:2011
33 General environment − air samples Mercury content
Range (0,2 – 9,0) µg w próbce
Atomic absorption spectrometry with amalgamation technique PB-04/JŚ wydanie 12 z dnia 6.12.2022r.
34 Water Stężenie manganu i żelaza
Mn (0,004 – 2,0) mg/dm3 Fe (0,008 – 4,0) mg/dm3
Flame atomic absorption spectrometry (FAAS) PB-20/JŚ wydanie 5 z dnia 6.12.2022r.
35 Water, wastewater Mercury concentration
Range (0,0002 − 0,3) mg/dm3
Atomic absorption spectrometry with amalgamation technique PB-04/JŚ wydanie 12 z dnia 6.12.2022r.
Pracownia Wód i Ścieków
36 Water, wastewater Chemical oxygen demand - COD
Range (5 – 25000) mg/dm3
Titrimetric method PB-13/JŚ wydanie 6 z dnia 6.12.2022r.
37 Water, wastewater Chloride concentration
Range (2,5 – 1000) mg/dm3
Titrimetric method PN-ISO 9297:1994
38 Water, wastewater Orthophosphate concentration
Range (0,025 – 6,0) mg/dm3 PO4
Spectrophotometric method PN-EN ISO 6878:2006 punkt 4 +Ap1:2010 +Ap2:2010

Reference standards (33)

INB 11 wyd.5 z dnia 11.12.2025r.
PB-04/JŚ wydanie 12 z dnia 6.12.2022r.
PB-13/JŚ wydanie 6 z dnia 6.12.2022r.
PB-20/JŚ wydanie 5 z dnia 6.12.2022r.
PN-E-04040-03:1983
PN-EN ISO 6878:2006 punkt 4 +Ap1:2010 +Ap2:2010
PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 – punkt 10
PN-ISO 9297:1994
PN-N-01307:1994
PN-Z-04008-7:2002+Az1:2004
PN-Z-04016-10:2005
PN-Z-04023-02:1989
PN-Z-04028-01:1981
PN-Z-04041:1971
PN-Z-04081-01:1979
PN-Z-04108-6:2006+Az1:2009
PN-Z-04113-05:1986
PN-Z-04113-06:1986
PN-Z-04113-09:1992
PN-Z-04115-01:1978
PN-Z-04119-01:1978
PN-Z-04136-3:2003
PN-Z-04152-02:1986
PN-Z-04152-06:1993
PN-Z-04178-02:1987
PN-Z-04318:2005
PN-Z-04435:2011
PN-Z-04438:2021
PN-Z-04507:2022-05
PN-Z-04507:2022-05/Ap1:2022-08
PN-Z-04508:2022-05
PN-Z-04508:2022-05/Ap1:2022-08
PN-Z-04556:2024-09