{"lab":{"_id":"69ad52a3de79e566650fb5f8","accr_number":"AB 1168","country":"PL","accr_body":"PCA","address":"spółka z ograniczoną odpowiedzialnością, LABORATORIUM ŚRODOWISKOWE, ul. Chemików 1, 32-600 Oświęcim","categories":["environment","water"],"city":"Oświęcim","imported_at":"2026-03-08T10:42:43.265Z","methods_count":38,"name":"SYNTHOS DWORY 7","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1168.pdf"],"scope_summary":"","search_text":"synthos dwory 7 spółka z ograniczoną odpowiedzialnością, laboratorium środowiskowe, ul. chemików 1, 32-600 oświęcim other environment materials construction electronics food metrology water","status":"active","updated_at":"2026-03-08T14:50:20.681Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-14T14:01:41.194Z","email_confidence":"low","email_mx":true,"email_source":"https://www.synthosgroup.com/en/contact-2/head-office/","needs_review":true,"review_reason":"e-mail niepewny (low) — zweryfikuj","parse_date":"2026-08-14T14:01:41.194Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"C/9, C/29, C/30, C/36","pl":"Badania chemiczne – powietrze, woda, ścieki, gazy odlotowe","en":"Chemical tests – air, water, sewage, waste gases"},{"codes":"C/33/P","pl":"Badania chemiczne i pobieranie próbek – powietrze","en":"Chemical tests and sampling – air"},{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe i uciążliwe – oświetlenie, hałas)","en":"Tests concerning environmental engineering (environmental and climatic) – working environment (harmful and nuisance factors – lighting, noise)"},{"codes":"N/33/P","pl":"Badania właściwości fizycznych i pobieranie próbek – powietrze","en":"Tests of physical properties and sampling – air"}],"issue":{"no":"20","date":"24.03.2026"},"map_coord":[50.036411,19.254151],"map_geo":"nominatim-street","lab_locations":[{"name":"LABORATORIUM ŚRODOWISKOWE","address":"ul. Chemików 1, 32-600 Oświęcim","city":"Oświęcim","postal":"32-600"},{"name":"Pracownia Stanowisk Pracy i Imisji − Chromatografia Gazowa","address":"ul. Chemików 1, 32-600 Oświęcim","city":"Oświęcim","postal":"32-600"},{"name":"Pracownia Stanowisk Pracy i Imisji","address":"ul. Chemików 1, 32-600 Oświęcim","city":"Oświęcim","postal":"32-600"},{"name":"Pracownia AMA i ASA","address":"ul. Chemików 1, 32-600 Oświęcim","city":"Oświęcim","postal":"32-600"},{"name":"Pracownia Wód i Ścieków","address":"ul. Chemików 1, 32-600 Oświęcim","city":"Oświęcim","postal":"32-600"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/14/166f40c8fb68ee18aa5204fa8875dd3c/AB%201168.pdf","has_en":true,"category_counts":{"environment":33,"water":5,"construction":2,"materials":1,"petro":1},"category_scores":{"environment":25.93,"water":0.6,"construction":0.1,"materials":0.02,"petro":0.02},"has_zh":true},"methods":[{"_id":"6a7f1fc5bc25eed9be28d99d","lab_id":"69ad52a3de79e566650fb5f8","country":"PL","accr_number":"AB 1168","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie benzenu","parameters":[{"name":"Zakres","range":"(0,07 – 5,56) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie benzenu\nZakres (0,07 – 5,56) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04016-10:2005","norm_bases":["PN-Z-04016-10:2005"],"lab_section":"Pracownia Stanowisk Pracy i Imisji − Chromatografia Gazowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie benzenu\nZakres (0,07 – 5,56) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04016-10:2005 Srodowisko pracy − powietrze Stezenie benzenu\nZakres (0,07 – 5,56) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04016-10:2005","categories":["environment"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Benzene concentration","parameters_en":[{"name":"Range","range":"(0,07 – 5,56) mg/m3"}],"search_en":"Workplace environment − air Benzene concentration Gas chromatography with flame ionization detection (GC-FID) Range PN-Z-04016-10:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(0,07 – 5,56) mg/m3"}],"search_zh":"工作环境 − 空气 苯浓度 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-Z-04016-10:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作环境 − 空气","methodology_zh":"苯浓度"},{"_id":"6a7f1fc5bc25eed9be28d99e","lab_id":"69ad52a3de79e566650fb5f8","country":"PL","accr_number":"AB 1168","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie toluenu","parameters":[{"name":"Zakres","range":"(1,39 – 400) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie toluenu\nZakres (1,39 – 400) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04115-01:1978","norm_bases":["PN-Z-04115-01:1978"],"lab_section":"Pracownia Stanowisk Pracy i Imisji − Chromatografia Gazowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie toluenu\nZakres (1,39 – 400) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04115-01:1978 Srodowisko pracy − powietrze Stezenie toluenu\nZakres (1,39 – 400) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04115-01:1978","categories":["environment"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Toluene concentration","parameters_en":[{"name":"Range","range":"(1,39 – 400) mg/m3"}],"search_en":"Workplace environment − air Toluene concentration Gas chromatography with flame ionization detection (GC-FID) Range PN-Z-04115-01:1978","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(1,39 – 400) mg/m3"}],"search_zh":"工作环境 − 空气 甲苯浓度 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-Z-04115-01:1978","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作环境 − 空气","methodology_zh":"甲苯浓度"},{"_id":"6a7f1fc5bc25eed9be28d99f","lab_id":"69ad52a3de79e566650fb5f8","country":"PL","accr_number":"AB 1168","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie etylobenzenu","parameters":[{"name":"Zakres","range":"(1,39 – 800) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie etylobenzenu\nZakres (1,39 – 800) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04081-01:1979","norm_bases":["PN-Z-04081-01:1979"],"lab_section":"Pracownia Stanowisk Pracy i Imisji − Chromatografia Gazowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie etylobenzenu\nZakres (1,39 – 800) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04081-01:1979 Srodowisko pracy − powietrze Stezenie etylobenzenu\nZakres (1,39 – 800) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04081-01:1979","categories":["environment"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ethylbenzene concentration","parameters_en":[{"name":"Range","range":"(1,39 – 800) mg/m3"}],"search_en":"Workplace environment − air Ethylbenzene concentration Gas chromatography with flame ionization detection (GC-FID) Range PN-Z-04081-01:1979","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(1,39 – 800) mg/m3"}],"search_zh":"工作环境 − 空气 乙苯浓度 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-Z-04081-01:1979","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作环境 − 空气","methodology_zh":"乙苯浓度"},{"_id":"6a7f1fc5bc25eed9be28d9a0","lab_id":"69ad52a3de79e566650fb5f8","country":"PL","accr_number":"AB 1168","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie styrenu","parameters":[{"name":"Zakres","range":"(1,39 – 200) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie styrenu\nZakres (1,39 – 200) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04152-02:1986","norm_bases":["PN-Z-04152-02:1986"],"lab_section":"Pracownia Stanowisk Pracy i Imisji − Chromatografia Gazowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie styrenu\nZakres (1,39 – 200) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04152-02:1986 Srodowisko pracy − powietrze Stezenie styrenu\nZakres (1,39 – 200) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04152-02:1986","categories":["environment"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Styrene concentration","parameters_en":[{"name":"Range","range":"(1,39 – 200) mg/m3"}],"search_en":"Workplace environment − air Styrene concentration Gas chromatography with flame ionization detection (GC-FID) Range PN-Z-04152-02:1986","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(1,39 – 200) mg/m3"}],"search_zh":"工作环境 − 空气 苯乙烯浓度 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-Z-04152-02:1986","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作环境 − 空气","methodology_zh":"苯乙烯浓度"},{"_id":"6a7f1fc5bc25eed9be28d9a1","lab_id":"69ad52a3de79e566650fb5f8","country":"PL","accr_number":"AB 1168","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie akrylanu metylu","parameters":[{"name":"Zakres","range":"(1,39 – 178) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie akrylanu metylu\nZakres (1,39 – 178) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04113-05:1986","norm_bases":["PN-Z-04113-05:1986"],"lab_section":"Pracownia Stanowisk Pracy i Imisji − Chromatografia Gazowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie akrylanu metylu\nZakres (1,39 – 178) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04113-05:1986 Srodowisko pracy − powietrze Stezenie akrylanu metylu\nZakres (1,39 – 178) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04113-05:1986","categories":["environment"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(1,39 – 178) mg/m3"}],"search_en":"Workplace environment − air Gas chromatography with flame ionization detection (GC-FID) Range PN-Z-04113-05:1986","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(1,39 – 178) mg/m3"}],"search_zh":"工作环境 − 空气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-Z-04113-05:1986","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作环境 − 空气"},{"_id":"6a7f1fc5bc25eed9be28d9a2","lab_id":"69ad52a3de79e566650fb5f8","country":"PL","accr_number":"AB 1168","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie akrylanu butylu","parameters":[{"name":"Zakres","range":"(1,39 – 178) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie akrylanu butylu\nZakres (1,39 – 178) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04113-06:1986","norm_bases":["PN-Z-04113-06:1986"],"lab_section":"Pracownia Stanowisk Pracy i Imisji − Chromatografia Gazowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie akrylanu butylu\nZakres (1,39 – 178) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04113-06:1986 Srodowisko pracy − powietrze Stezenie akrylanu butylu\nZakres (1,39 – 178) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04113-06:1986","categories":["environment"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(1,39 – 178) mg/m3"}],"search_en":"Workplace environment − air Gas chromatography with flame ionization detection (GC-FID) Range PN-Z-04113-06:1986","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(1,39 – 178) mg/m3"}],"search_zh":"工作环境 − 空气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-Z-04113-06:1986","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作环境 − 空气"},{"_id":"6a7f1fc5bc25eed9be28d9a3","lab_id":"69ad52a3de79e566650fb5f8","country":"PL","accr_number":"AB 1168","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie metakrylanu metylu","parameters":[{"name":"Zakres","range":"(1,39 – 600) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie metakrylanu metylu\nZakres (1,39 – 600) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04113-09:1992","norm_bases":["PN-Z-04113-09:1992"],"lab_section":"Pracownia Stanowisk Pracy i Imisji − Chromatografia Gazowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie metakrylanu metylu\nZakres (1,39 – 600) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04113-09:1992 Srodowisko pracy − powietrze Stezenie metakrylanu metylu\nZakres (1,39 – 600) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04113-09:1992","categories":["environment"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(1,39 – 600) mg/m3"}],"search_en":"Workplace environment − air Gas chromatography with flame ionization detection (GC-FID) Range PN-Z-04113-09:1992","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(1,39 – 600) mg/m3"}],"search_zh":"工作环境 − 空气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-Z-04113-09:1992","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作环境 − 空气"},{"_id":"6a7f1fc5bc25eed9be28d9a4","lab_id":"69ad52a3de79e566650fb5f8","country":"PL","accr_number":"AB 1168","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie akrylonitrylu","parameters":[{"name":"Zakres","range":"(0,13 – 35,56) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie akrylonitrylu\nZakres (0,13 – 35,56) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04556:2024-09","norm_bases":["PN-Z-04556:2024-09"],"lab_section":"Pracownia Stanowisk Pracy i Imisji − Chromatografia Gazowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie akrylonitrylu\nZakres (0,13 – 35,56) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04556:2024-09 Srodowisko pracy − powietrze Stezenie akrylonitrylu\nZakres (0,13 – 35,56) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04556:2024-09","categories":["environment"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,13 – 35,56) mg/m3"}],"search_en":"Workplace environment − air Gas chromatography with flame ionization detection (GC-FID) Range PN-Z-04556:2024-09","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(0,13 – 35,56) mg/m3"}],"search_zh":"工作环境 − 空气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-Z-04556:2024-09","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作环境 − 空气"},{"_id":"6a7f1fc5bc25eed9be28d9a5","lab_id":"69ad52a3de79e566650fb5f8","country":"PL","accr_number":"AB 1168","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie buta-1,3-dienu","parameters":[{"name":"Zakres","range":"(0,44 – 8,77) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie buta-1,3-dienu\nZakres (0,44 – 8,77) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04438:2021","norm_bases":["PN-Z-04438:2021"],"lab_section":"Pracownia Stanowisk Pracy i Imisji − Chromatografia Gazowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie buta-1,3-dienu\nZakres (0,44 – 8,77) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04438:2021 Srodowisko pracy − powietrze Stezenie buta-1,3-dienu\nZakres (0,44 – 8,77) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04438:2021","categories":["environment"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,44 – 8,77) mg/m3"}],"search_en":"Workplace environment − air Gas chromatography with flame ionization detection (GC-FID) Range PN-Z-04438:2021","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(0,44 – 8,77) mg/m3"}],"search_zh":"工作环境 − 空气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-Z-04438:2021","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作环境 − 空气"},{"_id":"6a7f1fc5bc25eed9be28d9a6","lab_id":"69ad52a3de79e566650fb5f8","country":"PL","accr_number":"AB 1168","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie metanolu","parameters":[{"name":"Zakres","range":"(1,39 – 600) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie metanolu\nZakres (1,39 – 600) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04028-01:1981","norm_bases":["PN-Z-04028-01:1981"],"lab_section":"Pracownia Stanowisk Pracy i Imisji − Chromatografia Gazowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie metanolu\nZakres (1,39 – 600) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04028-01:1981 Srodowisko pracy − powietrze Stezenie metanolu\nZakres (1,39 – 600) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04028-01:1981","categories":["environment"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Methanol concentration","parameters_en":[{"name":"Range","range":"(1,39 – 600) mg/m3"}],"search_en":"Workplace environment − air Methanol concentration Gas chromatography with flame ionization detection (GC-FID) Range PN-Z-04028-01:1981","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(1,39 – 600) mg/m3"}],"search_zh":"工作环境 − 空气 甲醇浓度 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-Z-04028-01:1981","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作环境 − 空气","methodology_zh":"甲醇浓度"},{"_id":"6a7f1fc5bc25eed9be28d9a7","lab_id":"69ad52a3de79e566650fb5f8","country":"PL","accr_number":"AB 1168","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie octanu metylu","parameters":[{"name":"Zakres","range":"(1,39 – 1200) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie octanu metylu\nZakres (1,39 – 1200) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04119-01:1978","norm_bases":["PN-Z-04119-01:1978"],"lab_section":"Pracownia Stanowisk Pracy i Imisji − Chromatografia Gazowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie octanu metylu\nZakres (1,39 – 1200) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04119-01:1978 Srodowisko pracy − powietrze Stezenie octanu metylu\nZakres (1,39 – 1200) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04119-01:1978","categories":["environment"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Methyl acetate concentration","parameters_en":[{"name":"Range","range":"(1,39 – 1200) mg/m3"}],"search_en":"Workplace environment − air Methyl acetate concentration Gas chromatography with flame ionization detection (GC-FID) Range PN-Z-04119-01:1978","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(1,39 – 1200) mg/m3"}],"search_zh":"工作环境 − 空气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-Z-04119-01:1978","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作环境 − 空气"},{"_id":"6a7f1fc5bc25eed9be28d9a8","lab_id":"69ad52a3de79e566650fb5f8","country":"PL","accr_number":"AB 1168","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie octanu etylu","parameters":[{"name":"Zakres","range":"(1,39 – 2936) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie octanu etylu\nZakres (1,39 – 2936) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04119-01:1978","norm_bases":["PN-Z-04119-01:1978"],"lab_section":"Pracownia Stanowisk Pracy i Imisji − Chromatografia Gazowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie octanu etylu\nZakres (1,39 – 2936) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04119-01:1978 Srodowisko pracy − powietrze Stezenie octanu etylu\nZakres (1,39 – 2936) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04119-01:1978","categories":["environment"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ethyl acetate concentration","parameters_en":[{"name":"Range","range":"(1,39 – 2936) mg/m3"}],"search_en":"Workplace environment − air Ethyl acetate concentration Gas chromatography with flame ionization detection (GC-FID) Range PN-Z-04119-01:1978","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(1,39 – 2936) mg/m3"}],"search_zh":"工作环境 − 空气 乙酸乙酯浓度 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-Z-04119-01:1978","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作环境 − 空气","methodology_zh":"乙酸乙酯浓度"},{"_id":"6a7f1fc5bc25eed9be28d9a9","lab_id":"69ad52a3de79e566650fb5f8","country":"PL","accr_number":"AB 1168","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie octanu winylu","parameters":[{"name":"Zakres","range":"(1,39 – 178) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie octanu winylu\nZakres (1,39 – 178) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04178-02:1987","norm_bases":["PN-Z-04178-02:1987"],"lab_section":"Pracownia Stanowisk Pracy i Imisji − Chromatografia Gazowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie octanu winylu\nZakres (1,39 – 178) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04178-02:1987 Srodowisko pracy − powietrze Stezenie octanu winylu\nZakres (1,39 – 178) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04178-02:1987","categories":["environment"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Vinyl acetate concentration","parameters_en":[{"name":"Range","range":"(1,39 – 178) mg/m3"}],"search_en":"Workplace environment − air Vinyl acetate concentration Gas chromatography with flame ionization detection (GC-FID) Range PN-Z-04178-02:1987","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(1,39 – 178) mg/m3"}],"search_zh":"工作环境 − 空气 乙酸乙烯酯浓度 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-Z-04178-02:1987","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作环境 − 空气","methodology_zh":"乙酸乙烯酯浓度"},{"_id":"6a7f1fc5bc25eed9be28d9aa","lab_id":"69ad52a3de79e566650fb5f8","country":"PL","accr_number":"AB 1168","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie etanolu","parameters":[{"name":"Zakres","range":"(1,39 – 3800) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie etanolu\nZakres (1,39 – 3800) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04023-02:1989","norm_bases":["PN-Z-04023-02:1989"],"lab_section":"Pracownia Stanowisk Pracy i Imisji − Chromatografia Gazowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie etanolu\nZakres (1,39 – 3800) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04023-02:1989 Srodowisko pracy − powietrze Stezenie etanolu\nZakres (1,39 – 3800) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04023-02:1989","categories":["environment"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ethanol concentration","parameters_en":[{"name":"Range","range":"(1,39 – 3800) mg/m3"}],"search_en":"Workplace environment − air Ethanol concentration Gas chromatography with flame ionization detection (GC-FID) Range PN-Z-04023-02:1989","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(1,39 – 3800) mg/m3"}],"search_zh":"工作环境 − 空气 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-Z-04023-02:1989","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作环境 − 空气"},{"_id":"6a7f1fc5bc25eed9be28d9ab","lab_id":"69ad52a3de79e566650fb5f8","country":"PL","accr_number":"AB 1168","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie pentanu","parameters":[{"name":"Zakres","range":"(55 – 6000) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie pentanu\nZakres (55 – 6000) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04318:2005","norm_bases":["PN-Z-04318:2005"],"lab_section":"Pracownia Stanowisk Pracy i Imisji − Chromatografia Gazowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie pentanu\nZakres (55 – 6000) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04318:2005 Srodowisko pracy − powietrze Stezenie pentanu\nZakres (55 – 6000) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04318:2005","categories":["environment"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pentane concentration","parameters_en":[{"name":"Range","range":"(55 – 6000) mg/m3"}],"search_en":"Workplace environment − air Pentane concentration Gas chromatography with flame ionization detection (GC-FID) Range PN-Z-04318:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(55 – 6000) mg/m3"}],"search_zh":"工作环境 − 空气 戊烷浓度 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-Z-04318:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作环境 − 空气","methodology_zh":"戊烷浓度"},{"_id":"6a7f1fc5bc25eed9be28d9ac","lab_id":"69ad52a3de79e566650fb5f8","country":"PL","accr_number":"AB 1168","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie heksanu","parameters":[{"name":"Zakres","range":"(1,1 – 111,1) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie heksanu\nZakres (1,1 – 111,1) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04136-3:2003","norm_bases":["PN-Z-04136-3:2003"],"lab_section":"Pracownia Stanowisk Pracy i Imisji − Chromatografia Gazowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie heksanu\nZakres (1,1 – 111,1) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04136-3:2003 Srodowisko pracy − powietrze Stezenie heksanu\nZakres (1,1 – 111,1) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04136-3:2003","categories":["environment"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hexane concentration","parameters_en":[{"name":"Range","range":"(1,1 – 111,1) mg/m3"}],"search_en":"Workplace environment − air Hexane concentration Gas chromatography with flame ionization detection (GC-FID) Range PN-Z-04136-3:2003","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(1,1 – 111,1) mg/m3"}],"search_zh":"工作环境 − 空气 正己烷浓度 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-Z-04136-3:2003","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作环境 − 空气","methodology_zh":"正己烷浓度"},{"_id":"6a7f1fc5bc25eed9be28d9ad","lab_id":"69ad52a3de79e566650fb5f8","country":"PL","accr_number":"AB 1168","accr_body":"PCA","test_object":"Środowisko ogólne - próbki gazów odlotowych pobrane na rurki z sorbentem","methodology":"Zawartość octanu winylu","parameters":[{"name":"Zakres","range":"(0,0125 − 0,4) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość octanu winylu\nZakres (0,0125 − 0,4) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04178-02:1987","norm_bases":["PN-Z-04178-02:1987"],"lab_section":"Pracownia Stanowisk Pracy i Imisji − Chromatografia Gazowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - próbki gazów odlotowych pobrane na rurki z sorbentem Zawartość octanu winylu\nZakres (0,0125 − 0,4) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04178-02:1987 Srodowisko ogolne - probki gazow odlotowych pobrane na rurki z sorbentem Zawartosc octanu winylu\nZakres (0,0125 − 0,4) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04178-02:1987","categories":["environment"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Vinyl acetate content","parameters_en":[{"name":"Range","range":"(0,0125 − 0,4) mg w próbce"}],"search_en":"General environment - waste gas samples collected on sorbent tubes Vinyl acetate content Gas chromatography with flame ionization detection (GC-FID) Range PN-Z-04178-02:1987","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"General environment - waste gas samples collected on sorbent tubes","parameters_zh":[{"name":"范围","range":"(0,0125 − 0,4) mg w próbce"}],"search_zh":"一般环境 － 采集于吸附管中的排放气体样品 乙酸乙烯酯含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-Z-04178-02:1987","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"一般环境 － 采集于吸附管中的排放气体样品","methodology_zh":"乙酸乙烯酯含量"},{"_id":"6a7f1fc5bc25eed9be28d9ae","lab_id":"69ad52a3de79e566650fb5f8","country":"PL","accr_number":"AB 1168","accr_body":"PCA","test_object":"Środowisko ogólne - próbki gazów odlotowych pobrane na rurki z sorbentem","methodology":"Zawartość styrenu","parameters":[{"name":"Zakres","range":"(0,0125 − 0,4) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość styrenu\nZakres (0,0125 − 0,4) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04152-06:1993","norm_bases":["PN-Z-04152-06:1993"],"lab_section":"Pracownia Stanowisk Pracy i Imisji − Chromatografia Gazowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - próbki gazów odlotowych pobrane na rurki z sorbentem Zawartość styrenu\nZakres (0,0125 − 0,4) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04152-06:1993 Srodowisko ogolne - probki gazow odlotowych pobrane na rurki z sorbentem Zawartosc styrenu\nZakres (0,0125 − 0,4) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04152-06:1993","categories":["environment"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Styrene content","parameters_en":[{"name":"Range","range":"(0,0125 − 0,4) mg w próbce"}],"search_en":"General environment - waste gas samples collected on sorbent tubes Styrene content Gas chromatography with flame ionization detection (GC-FID) Range PN-Z-04152-06:1993","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"General environment - waste gas samples collected on sorbent tubes","parameters_zh":[{"name":"范围","range":"(0,0125 − 0,4) mg w próbce"}],"search_zh":"一般环境 － 采集于吸附管中的排放气体样品 苯乙烯含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-Z-04152-06:1993","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"一般环境 － 采集于吸附管中的排放气体样品","methodology_zh":"苯乙烯含量"},{"_id":"6a7f1fc5bc25eed9be28d9af","lab_id":"69ad52a3de79e566650fb5f8","country":"PL","accr_number":"AB 1168","accr_body":"PCA","test_object":"Środowisko ogólne - próbki gazów odlotowych pobrane na rurki z sorbentem","methodology":"Zawartość heksanu","parameters":[{"name":"Zakres","range":"(0,02 – 2,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość heksanu\nZakres (0,02 – 2,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04136-3:2003","norm_bases":["PN-Z-04136-3:2003"],"lab_section":"Pracownia Stanowisk Pracy i Imisji − Chromatografia Gazowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - próbki gazów odlotowych pobrane na rurki z sorbentem Zawartość heksanu\nZakres (0,02 – 2,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04136-3:2003 Srodowisko ogolne - probki gazow odlotowych pobrane na rurki z sorbentem Zawartosc heksanu\nZakres (0,02 – 2,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04136-3:2003","categories":["environment"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hexane content","parameters_en":[{"name":"Range","range":"(0,02 – 2,0) mg w próbce"}],"search_en":"General environment - waste gas samples collected on sorbent tubes Hexane content Gas chromatography with flame ionization detection (GC-FID) Range PN-Z-04136-3:2003","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"General environment - waste gas samples collected on sorbent tubes","parameters_zh":[{"name":"范围","range":"(0,02 – 2,0) mg w próbce"}],"search_zh":"一般环境 － 采集于吸附管中的排放气体样品 正己烷含量 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-Z-04136-3:2003","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"一般环境 － 采集于吸附管中的排放气体样品","methodology_zh":"正己烷含量"},{"_id":"6a7f1fc5bc25eed9be28d9b0","lab_id":"69ad52a3de79e566650fb5f8","country":"PL","accr_number":"AB 1168","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","parameters":[{"name":"czynniki pyłowe − frakcja wdychalna − frakcja respirabilna"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nczynniki pyłowe − frakcja wdychalna − frakcja respirabilna\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":"Pracownia Stanowisk Pracy i Imisji","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nczynniki pyłowe − frakcja wdychalna − frakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy − powietrze Pobieranie probek do oceny narazenia zawodowego na:\nczynniki pylowe − frakcja wdychalna − frakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004","categories":["environment"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"dust agents − inhalable fraction − respirable fraction"}],"search_en":"Workplace environment − air Sampling for the assessment of occupational exposure to: Personal dosimetry method dust agents − inhalable fraction − respirable fraction PN-Z-04008-7:2002+Az1:2004","technique_en":"Personal dosimetry method","test_object_en":"Workplace environment − air","methodology_zh":"职业接触评估采样，针对：","search_zh":"工作环境 − 空气 职业接触评估采样，针对： 个体剂量测定法 粉尘因子 － 可吸入性粉尘 － 呼吸性粉尘 PN-Z-04008-7:2002+Az1:2004","technique_zh":"个体剂量测定法","test_object_zh":"工作环境 − 空气","parameters_zh":[{"name":"粉尘因子 － 可吸入性粉尘 － 呼吸性粉尘"}]},{"_id":"6a7f1fc5bc25eed9be28d9b1","lab_id":"69ad52a3de79e566650fb5f8","country":"PL","accr_number":"AB 1168","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","parameters":[{"name":"substancje organiczne, w tym − frakcja wdychalna"},{"name":"substancje nieorganiczne, w tym − frakcja wdychalna − frakcja respirabilna"},{"name":"metale i ich związki, w tym − frakcja wdychalna − frakcja respirabilna"}],"technique":"Metoda dozymetrii indywidualnej; Metoda stacjonarna","techniques":["Metoda dozymetrii indywidualnej","Metoda stacjonarna"],"computed":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nsubstancje organiczne, w tym − frakcja wdychalna\nsubstancje nieorganiczne, w tym − frakcja wdychalna − frakcja respirabilna\nmetale i ich związki, w tym − frakcja wdychalna − frakcja respirabilna\nMetoda dozymetrii indywidualnej; Metoda stacjonarna","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":"Pracownia Stanowisk Pracy i Imisji","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nsubstancje organiczne, w tym − frakcja wdychalna\nsubstancje nieorganiczne, w tym − frakcja wdychalna − frakcja respirabilna\nmetale i ich związki, w tym − frakcja wdychalna − frakcja respirabilna\nMetoda dozymetrii indywidualnej; Metoda stacjonarna PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy − powietrze Pobieranie probek do oceny narazenia zawodowego na:\nZakres:\nsubstancje organiczne, w tym − frakcja wdychalna\nsubstancje nieorganiczne, w tym − frakcja wdychalna − frakcja respirabilna\nmetale i ich zwiazki, w tym − frakcja wdychalna − frakcja respirabilna\nMetoda dozymetrii indywidualnej; Metoda stacjonarna PN-Z-04008-7:2002+Az1:2004","categories":["materials","environment"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"organic substances, including − inhalable fraction"},{"name":"inorganic substances, including − inhalable fraction − respirable fraction"},{"name":"metals and their compounds, including − inhalable fraction − respirable fraction"}],"search_en":"Workplace environment − air Sampling for the assessment of occupational exposure to: Personal dosimetry method; Stationary method organic substances, including − inhalable fraction inorganic substances, including − inhalable fraction − respirable fraction metals and their compounds, including − inhalable fraction − respirable fraction PN-Z-04008-7:2002+Az1:2004","technique_en":"Personal dosimetry method; Stationary method","test_object_en":"Workplace environment − air","methodology_zh":"职业接触评估采样，针对：","search_zh":"工作环境 − 空气 职业接触评估采样，针对： 个体剂量测定法；定点测定法 PN-Z-04008-7:2002+Az1:2004","test_object_zh":"工作环境 − 空气","technique_zh":"个体剂量测定法；定点测定法"},{"_id":"6a7f1fc5bc25eed9be28d9b2","lab_id":"69ad52a3de79e566650fb5f8","country":"PL","accr_number":"AB 1168","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":"Pracownia Stanowisk Pracy i Imisji","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy − powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002+Az1:2004","categories":["environment"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Exposure index (calculated)","search_en":"Workplace environment − air Exposure index (calculated) PN-Z-04008-7:2002+Az1:2004","test_object_en":"Workplace environment − air","methodology_zh":"暴露指数（计算得出）","search_zh":"工作环境 − 空气 暴露指数（计算得出） PN-Z-04008-7:2002+Az1:2004","test_object_zh":"工作环境 − 空气"},{"_id":"6a7f1fc5bc25eed9be28d9b3","lab_id":"69ad52a3de79e566650fb5f8","country":"PL","accr_number":"AB 1168","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna","parameters":[{"name":"apatyty i fosforyty"},{"name":"asfalt naftowy"},{"name":"cement portlandzki"},{"name":"ditlenek tytanu"},{"name":"grafit naturalny"},{"name":"grafit syntetyczny"},{"name":"kaolin"},{"name":"krzemionka bezpostaciowa i syntetyczna"},{"name":"pyły drewna"},{"name":"pyły mąki"},{"name":"pyły niesklasyfikowane ze względu na toksyczność"},{"name":"pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"sadza techniczna"},{"name":"siarczan (VI) wapnia (gips)"},{"name":"talk"},{"name":"węgiel (kamienny, brunatny)"},{"name":"węglan magnezu wapnia (dolomit)"},{"name":"węglik krzemu, niewłóknisty"},{"name":"Zakres","range":"(0,13 – 20,42) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna\nZakres:\napatyty i fosforyty\nasfalt naftowy\ncement portlandzki\nditlenek tytanu\ngrafit naturalny\ngrafit syntetyczny\nkaolin\nkrzemionka bezpostaciowa i syntetyczna\npyły drewna\npyły mąki\npyły niesklasyfikowane ze względu na toksyczność\npyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nsadza techniczna\nsiarczan (VI) wapnia (gips)\ntalk\nwęgiel (kamienny, brunatny)\nwęglan magnezu wapnia (dolomit)\nwęglik krzemu, niewłóknisty\nZakres (0,13 – 20,42) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05","PN-Z-04507:2022-05/Ap1:2022-08"],"lab_section":"Pracownia Stanowisk Pracy i Imisji","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna\nZakres:\napatyty i fosforyty\nasfalt naftowy\ncement portlandzki\nditlenek tytanu\ngrafit naturalny\ngrafit syntetyczny\nkaolin\nkrzemionka bezpostaciowa i syntetyczna\npyły drewna\npyły mąki\npyły niesklasyfikowane ze względu na toksyczność\npyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nsadza techniczna\nsiarczan (VI) wapnia (gips)\ntalk\nwęgiel (kamienny, brunatny)\nwęglan magnezu wapnia (dolomit)\nwęglik krzemu, niewłóknisty\nZakres (0,13 – 20,42) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 Srodowisko pracy − powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia – frakcja wdychalna\nZakres:\napatyty i fosforyty\nasfalt naftowy\ncement portlandzki\nditlenek tytanu\ngrafit naturalny\ngrafit syntetyczny\nkaolin\nkrzemionka bezpostaciowa i syntetyczna\npyly drewna\npyly maki\npyly niesklasyfikowane ze wzgledu na toksycznosc\npyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nsadza techniczna\nsiarczan (VI) wapnia (gips)\ntalk\nwegiel (kamienny, brunatny)\nweglan magnezu wapnia (dolomit)\nweglik krzemu, niewloknisty\nZakres (0,13 – 20,42) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of harmful dust agents – inhalable fraction","parameters_en":[{"name":"apatites and phosphorites"},{"name":"petroleum bitumen"},{"name":"portland cement"},{"name":"titanium dioxide"},{"name":"natural graphite"},{"name":"synthetic graphite"},{"name":"kaolin"},{"name":"amorphous and synthetic silica"},{"name":"wood dusts"},{"name":"flour dusts"},{"name":"dusts not classified according to toxicity"},{"name":"organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"carbon black"},{"name":"calcium sulfate (VI) (gypsum)"},{"name":"talc"},{"name":"coal (hard, brown)"},{"name":"calcium magnesium carbonate (dolomite)"},{"name":"silicon carbide, non-fibrous"},{"name":"Range","range":"(0,13 – 20,42) mg/m3"}],"search_en":"Workplace environment − air Concentration of harmful dust agents – inhalable fraction Gravimetric method apatites and phosphorites petroleum bitumen portland cement titanium dioxide natural graphite synthetic graphite kaolin amorphous and synthetic silica wood dusts flour dusts dusts not classified according to toxicity organic dusts of animal and plant origin, excluding wood and flour dusts carbon black calcium sulfate (VI) (gypsum) talc coal (hard, brown) calcium magnesium carbonate (dolomite) silicon carbide, non-fibrous Range PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"磷灰石与磷块岩"},{"name":"石油沥青"},{"name":"硅酸盐水泥"},{"name":"二氧化钛"},{"name":"天然石墨"},{"name":"合成石墨"},{"name":"高岭土"},{"name":"无定形与合成二氧化硅"},{"name":"木粉尘"},{"name":"面粉粉尘"},{"name":"未按毒性分类的粉尘"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"炭黑"},{"name":"硫酸钙（VI）（石膏）"},{"name":"滑石"},{"name":"煤（烟煤、褐煤）"},{"name":"碳酸钙镁（白云石）"},{"name":"碳化硅，非纤维状"},{"name":"范围","range":"(0,13 – 20,42) mg/m3"}],"search_zh":"工作环境 − 空气 有害粉尘因素浓度 — 可吸入组分 重量法 磷灰石与磷块岩 石油沥青 硅酸盐水泥 二氧化钛 天然石墨 合成石墨 高岭土 无定形与合成二氧化硅 木粉尘 面粉粉尘 未按毒性分类的粉尘 动植物来源有机粉尘，木粉和面粉除外 炭黑 硫酸钙（VI）（石膏） 滑石 煤（烟煤、褐煤） 碳酸钙镁（白云石） 碳化硅，非纤维状 范围 PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作环境 − 空气","methodology_zh":"有害粉尘因素浓度 — 可吸入组分"},{"_id":"6a7f1fc5bc25eed9be28d9b4","lab_id":"69ad52a3de79e566650fb5f8","country":"PL","accr_number":"AB 1168","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna","parameters":[{"name":"apatyty i fosforyty"},{"name":"cement portlandzki"},{"name":"grafit naturalny"},{"name":"krzemionka bezpostaciowa i syntetyczna"},{"name":"pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"węgiel (kamienny, brunatny)"},{"name":"Zakres","range":"(0,09 – 21,93) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna\nZakres:\napatyty i fosforyty\ncement portlandzki\ngrafit naturalny\nkrzemionka bezpostaciowa i syntetyczna\npyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nwęgiel (kamienny, brunatny)\nZakres (0,09 – 21,93) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04508:2022-05","PN-Z-04508:2022-05/Ap1:2022-08"],"lab_section":"Pracownia Stanowisk Pracy i Imisji","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna\nZakres:\napatyty i fosforyty\ncement portlandzki\ngrafit naturalny\nkrzemionka bezpostaciowa i syntetyczna\npyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nwęgiel (kamienny, brunatny)\nZakres (0,09 – 21,93) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 Srodowisko pracy − powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia – frakcja respirabilna\nZakres:\napatyty i fosforyty\ncement portlandzki\ngrafit naturalny\nkrzemionka bezpostaciowa i syntetyczna\npyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nwegiel (kamienny, brunatny)\nZakres (0,09 – 21,93) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of harmful dust agents – respirable fraction","parameters_en":[{"name":"apatites and phosphorites"},{"name":"portland cement"},{"name":"natural graphite"},{"name":"amorphous and synthetic silica"},{"name":"organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"coal (hard, brown)"},{"name":"Range","range":"(0,09 – 21,93) mg/m3"}],"search_en":"Workplace environment − air Concentration of harmful dust agents – respirable fraction Gravimetric method apatites and phosphorites portland cement natural graphite amorphous and synthetic silica organic dusts of animal and plant origin, excluding wood and flour dusts coal (hard, brown) Range PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"天然石墨"},{"name":"无定形与合成二氧化硅"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"煤（烟煤、褐煤）"},{"name":"范围","range":"(0,09 – 21,93) mg/m3"}],"search_zh":"工作环境 − 空气 有害粉尘因素浓度 — 呼吸性组分 重量法 磷灰石与磷块岩 硅酸盐水泥 天然石墨 无定形与合成二氧化硅 动植物来源有机粉尘，木粉和面粉除外 煤（烟煤、褐煤） 范围 PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作环境 − 空气","methodology_zh":"有害粉尘因素浓度 — 呼吸性组分"},{"_id":"6a7f1fc5bc25eed9be28d9b5","lab_id":"69ad52a3de79e566650fb5f8","country":"PL","accr_number":"AB 1168","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie olejów mineralnych wysokorafinowanych z wyłączeniem cieczy obróbkowych – frakcja wdychalna","parameters":[{"name":"Zakres","range":"(0,5 – 10) mg/m3"}],"technique":"Metoda spektrometrii w nadfiolecie","techniques":["Metoda spektrometrii w nadfiolecie"],"computed":[],"activity":"Stężenie olejów mineralnych wysokorafinowanych z wyłączeniem cieczy obróbkowych – frakcja wdychalna\nZakres (0,5 – 10) mg/m3\nMetoda spektrometrii w nadfiolecie","reference":"PN-Z-04108-6:2006+Az1:2009","norm_bases":["PN-Z-04108-6:2006+Az1:2009"],"lab_section":"Pracownia Stanowisk Pracy i Imisji","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie olejów mineralnych wysokorafinowanych z wyłączeniem cieczy obróbkowych – frakcja wdychalna\nZakres (0,5 – 10) mg/m3\nMetoda spektrometrii w nadfiolecie PN-Z-04108-6:2006+Az1:2009 Srodowisko pracy − powietrze Stezenie olejow mineralnych wysokorafinowanych z wylaczeniem cieczy obrobkowych – frakcja wdychalna\nZakres (0,5 – 10) mg/m3\nMetoda spektrometrii w nadfiolecie PN-Z-04108-6:2006+Az1:2009","categories":["environment","petro"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,5 – 10) mg/m3"}],"search_en":"Workplace environment − air Range PN-Z-04108-6:2006+Az1:2009","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(0,5 – 10) mg/m3"}],"search_zh":"工作环境 − 空气 范围 PN-Z-04108-6:2006+Az1:2009","test_object_zh":"工作环境 − 空气"},{"_id":"6a7f1fc5bc25eed9be28d9b6","lab_id":"69ad52a3de79e566650fb5f8","country":"PL","accr_number":"AB 1168","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie amoniaku","parameters":[{"name":"Zakres","range":"(2 – 60) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie amoniaku\nZakres (2 – 60) mg/m3\nMetoda spektrofotometryczna","reference":"PN-Z-04041:1971","norm_bases":["PN-Z-04041:1971"],"lab_section":"Pracownia Stanowisk Pracy i Imisji","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie amoniaku\nZakres (2 – 60) mg/m3\nMetoda spektrofotometryczna PN-Z-04041:1971 Srodowisko pracy − powietrze Stezenie amoniaku\nZakres (2 – 60) mg/m3\nMetoda spektrofotometryczna PN-Z-04041:1971","categories":["environment"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonia concentration","parameters_en":[{"name":"Range","range":"(2 – 60) mg/m3"}],"search_en":"Workplace environment − air Ammonia concentration Spectrophotometric method Range PN-Z-04041:1971","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(2 – 60) mg/m3"}],"search_zh":"工作环境 − 空气 氨浓度 分光光度法 范围 PN-Z-04041:1971","technique_zh":"分光光度法","test_object_zh":"工作环境 − 空气","methodology_zh":"氨浓度"},{"_id":"6a7f1fc5bc25eed9be28d9b7","lab_id":"69ad52a3de79e566650fb5f8","country":"PL","accr_number":"AB 1168","accr_body":"PCA","test_object":"Środowisko pracy − hałas","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(50 –139) dB"},{"name":"Szczytowy poziom dźwięku C"},{"name":"Zakres","range":"(50 – 140) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (50 –139) dB\nSzczytowy poziom dźwięku C\nZakres (50 – 140) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 – punkt 10","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 – punkt 10"],"lab_section":"Pracownia Stanowisk Pracy i Imisji","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (50 –139) dB\nSzczytowy poziom dźwięku C\nZakres (50 – 140) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 – punkt 10 Srodowisko pracy − halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres:\nZakres (50 –139) dB\nSzczytowy poziom dzwieku C\nZakres (50 – 140) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej Strategie 2 – punkt 10","categories":["environment"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters_en":[{"name":"Range","range":"(50 –139) dB"},{"name":"C-weighted peak sound pressure level"},{"name":"Range","range":"(50 – 140) dB"}],"search_en":"Workplace environment − noise A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method Range C-weighted peak sound pressure level Range PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 – punkt 10","technique_en":"Direct measurement method","test_object_en":"Workplace environment − noise","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(50 –139) dB"},{"name":"C 计权峰值声级"},{"name":"范围","range":"(50 – 140) dB"}],"search_zh":"工作环境 − 噪声 A 计权等效声级 A 计权最大声级 直接测量法 范围 C 计权峰值声级 范围 PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 – punkt 10","technique_zh":"直接测量法","test_object_zh":"工作环境 − 噪声"},{"_id":"6a7f1fc5bc25eed9be28d9b8","lab_id":"69ad52a3de79e566650fb5f8","country":"PL","accr_number":"AB 1168","accr_body":"PCA","test_object":"Środowisko pracy − hałas","methodology":"Poziom ekspozycji na hałas odniesiony do:","parameters":[{"name":"8-godz. dobowego wymiaru czasu pracy (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas odniesiony do:\n8-godz. dobowego wymiaru czasu pracy (z obliczeń)","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 – punkt 10","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 – punkt 10"],"lab_section":"Pracownia Stanowisk Pracy i Imisji","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − hałas Poziom ekspozycji na hałas odniesiony do:\n8-godz. dobowego wymiaru czasu pracy (z obliczeń) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 – punkt 10 Srodowisko pracy − halas Poziom ekspozycji na halas odniesiony do:\n8-godz. dobowego wymiaru czasu pracy (z obliczen) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej Strategie 2 – punkt 10","categories":["environment"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Noise exposure level referred to:","parameters_en":[{"name":"an 8-hour daily working time (calculated)"}],"search_en":"Workplace environment − noise Noise exposure level referred to: an 8-hour daily working time (calculated) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 – punkt 10","test_object_en":"Workplace environment − noise","methodology_zh":"噪声暴露级，参照：","search_zh":"工作环境 − 噪声 噪声暴露级，参照： 每日 8 小时工作时间（由计算得出） PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 – punkt 10","test_object_zh":"工作环境 − 噪声","parameters_zh":[{"name":"每日 8 小时工作时间（由计算得出）"}]},{"_id":"6a7f1fc5bc25eed9be28d9b9","lab_id":"69ad52a3de79e566650fb5f8","country":"PL","accr_number":"AB 1168","accr_body":"PCA","test_object":"Środowisko pracy − oświetlenie elektryczne we wnętrzach","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(5 – 8600) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (5 – 8600) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-E-04040-03:1983 | INB 11 wyd.5 z dnia 11.12.2025r.","norm_bases":["PN-E-04040-03:1983","INB 11 wyd.5 z dnia 11.12.2025r."],"lab_section":"Pracownia Stanowisk Pracy i Imisji","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − oświetlenie elektryczne we wnętrzach Natężenie oświetlenia\nZakres (5 – 8600) lx\nMetoda pomiarowa bezpośrednia PN-E-04040-03:1983 | INB 11 wyd.5 z dnia 11.12.2025r. Srodowisko pracy − oswietlenie elektryczne we wnetrzach Natezenie oswietlenia\nZakres (5 – 8600) lx\nMetoda pomiarowa bezposrednia PN-E-04040-03:1983 | INB 11 wyd.5 z dnia 11.12.2025r.","categories":["environment"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance","parameters_en":[{"name":"Range","range":"(5 – 8600) lx"}],"search_en":"Workplace environment − indoor electric lighting Illuminance Direct measurement method Range PN-E-04040-03:1983 | INB 11 wyd.5 z dnia 11.12.2025r.","technique_en":"Direct measurement method","test_object_en":"Workplace environment − indoor electric lighting","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(5 – 8600) lx"}],"search_zh":"工作场所环境 − 室内电气照明 照度 直接测量法 范围 PN-E-04040-03:1983 | INB 11 wyd.5 z dnia 11.12.2025r.","technique_zh":"直接测量法","test_object_zh":"工作场所环境 − 室内电气照明"},{"_id":"6a7f1fc5bc25eed9be28d9ba","lab_id":"69ad52a3de79e566650fb5f8","country":"PL","accr_number":"AB 1168","accr_body":"PCA","test_object":"Środowisko pracy − oświetlenie elektryczne we wnętrzach","methodology":"Równomierność oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"PN-E-04040-03:1983 | INB 11 wyd.5 z dnia 11.12.2025r.","norm_bases":["PN-E-04040-03:1983","INB 11 wyd.5 z dnia 11.12.2025r."],"lab_section":"Pracownia Stanowisk Pracy i Imisji","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − oświetlenie elektryczne we wnętrzach Równomierność oświetlenia (z obliczeń) PN-E-04040-03:1983 | INB 11 wyd.5 z dnia 11.12.2025r. Srodowisko pracy − oswietlenie elektryczne we wnetrzach Rownomiernosc oswietlenia (z obliczen) PN-E-04040-03:1983 | INB 11 wyd.5 z dnia 11.12.2025r.","categories":["environment"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance uniformity (calculated)","search_en":"Workplace environment − indoor electric lighting Illuminance uniformity (calculated) PN-E-04040-03:1983 | INB 11 wyd.5 z dnia 11.12.2025r.","test_object_en":"Workplace environment − indoor electric lighting","methodology_zh":"照度均匀度（计算值）","search_zh":"工作场所环境 − 室内电气照明 照度均匀度（计算值） PN-E-04040-03:1983 | INB 11 wyd.5 z dnia 11.12.2025r.","test_object_zh":"工作场所环境 − 室内电气照明"},{"_id":"6a7f1fc5bc25eed9be28d9bb","lab_id":"69ad52a3de79e566650fb5f8","country":"PL","accr_number":"AB 1168","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie rtęci, par i jej związków nieorganicznych – w przeliczeniu na Hg","parameters":[{"name":"Zakres","range":"(0,002 − 0,085) mg/m3"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","techniques":["Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji"],"computed":[],"activity":"Stężenie rtęci, par i jej związków nieorganicznych – w przeliczeniu na Hg\nZakres (0,002 − 0,085) mg/m3\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"PB-04/JŚ wydanie 12 z dnia 6.12.2022r.","norm_bases":["PB-04/JŚ wydanie 12 z dnia 6.12.2022r."],"lab_section":"Pracownia AMA i ASA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie rtęci, par i jej związków nieorganicznych – w przeliczeniu na Hg\nZakres (0,002 − 0,085) mg/m3\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji PB-04/JŚ wydanie 12 z dnia 6.12.2022r. Srodowisko pracy − powietrze Stezenie rteci, par i jej zwiazkow nieorganicznych – w przeliczeniu na Hg\nZakres (0,002 − 0,085) mg/m3\nMetoda absorpcyjnej spektrometrii atomowej z technika amalgamacji PB-04/JS wydanie 12 z dnia 6.12.2022r.","categories":["environment"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,002 − 0,085) mg/m3"}],"search_en":"Workplace environment − air Atomic absorption spectrometry with amalgamation technique Range PB-04/JŚ wydanie 12 z dnia 6.12.2022r.","technique_en":"Atomic absorption spectrometry with amalgamation technique","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(0,002 − 0,085) mg/m3"}],"search_zh":"工作环境 − 空气 原子吸收光谱法（汞齐化技术） 范围 PB-04/JŚ wydanie 12 z dnia 6.12.2022r.","technique_zh":"原子吸收光谱法（汞齐化技术）","test_object_zh":"工作环境 − 空气"},{"_id":"6a7f1fc5bc25eed9be28d9bc","lab_id":"69ad52a3de79e566650fb5f8","country":"PL","accr_number":"AB 1168","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie wodorotlenku sodu","parameters":[{"name":"Zakres","range":"(0,024 − 2,0) mg/m3"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie wodorotlenku sodu\nZakres (0,024 − 2,0) mg/m3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04435:2011","norm_bases":["PN-Z-04435:2011"],"lab_section":"Pracownia AMA i ASA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie wodorotlenku sodu\nZakres (0,024 − 2,0) mg/m3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04435:2011 Srodowisko pracy − powietrze Stezenie wodorotlenku sodu\nZakres (0,024 − 2,0) mg/m3\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04435:2011","categories":["environment"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sodium hydroxide concentration","parameters_en":[{"name":"Range","range":"(0,024 − 2,0) mg/m3"}],"search_en":"Workplace environment − air Sodium hydroxide concentration Flame atomic absorption spectrometry (FAAS) Range PN-Z-04435:2011","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(0,024 − 2,0) mg/m3"}],"search_zh":"工作环境 − 空气 氢氧化钠浓度 火焰原子吸收光谱法（FAAS） 范围 PN-Z-04435:2011","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作环境 − 空气","methodology_zh":"氢氧化钠浓度"},{"_id":"6a7f1fc5bc25eed9be28d9bd","lab_id":"69ad52a3de79e566650fb5f8","country":"PL","accr_number":"AB 1168","accr_body":"PCA","test_object":"Środowisko ogólne − próbki powietrza","methodology":"Zawartość rtęci","parameters":[{"name":"Zakres","range":"(0,2 – 9,0) µg w próbce"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","techniques":["Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji"],"computed":[],"activity":"Zawartość rtęci\nZakres (0,2 – 9,0) µg w próbce\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"PB-04/JŚ wydanie 12 z dnia 6.12.2022r.","norm_bases":["PB-04/JŚ wydanie 12 z dnia 6.12.2022r."],"lab_section":"Pracownia AMA i ASA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne − próbki powietrza Zawartość rtęci\nZakres (0,2 – 9,0) µg w próbce\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji PB-04/JŚ wydanie 12 z dnia 6.12.2022r. Srodowisko ogolne − probki powietrza Zawartosc rteci\nZakres (0,2 – 9,0) µg w probce\nMetoda absorpcyjnej spektrometrii atomowej z technika amalgamacji PB-04/JS wydanie 12 z dnia 6.12.2022r.","categories":["environment"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury content","parameters_en":[{"name":"Range","range":"(0,2 – 9,0) µg w próbce"}],"search_en":"General environment − air samples Mercury content Atomic absorption spectrometry with amalgamation technique Range PB-04/JŚ wydanie 12 z dnia 6.12.2022r.","technique_en":"Atomic absorption spectrometry with amalgamation technique","test_object_en":"General environment − air samples","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,2 – 9,0) µg w próbce"}],"search_zh":"汞含量 原子吸收光谱法（汞齐化技术） 范围 PB-04/JŚ wydanie 12 z dnia 6.12.2022r.","technique_zh":"原子吸收光谱法（汞齐化技术）"},{"_id":"6a7f1fc5bc25eed9be28d9be","lab_id":"69ad52a3de79e566650fb5f8","country":"PL","accr_number":"AB 1168","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie manganu i żelaza","parameters":[{"name":"Mn","range":"(0,004 – 2,0) mg/dm3"},{"name":"Fe","range":"(0,008 – 4,0) mg/dm3"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie manganu i żelaza\nZakres:\nMn (0,004 – 2,0) mg/dm3\nFe (0,008 – 4,0) mg/dm3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PB-20/JŚ wydanie 5 z dnia 6.12.2022r.","norm_bases":["PB-20/JŚ wydanie 5 z dnia 6.12.2022r."],"lab_section":"Pracownia AMA i ASA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie manganu i żelaza\nZakres:\nMn (0,004 – 2,0) mg/dm3\nFe (0,008 – 4,0) mg/dm3\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-20/JŚ wydanie 5 z dnia 6.12.2022r. Woda Stezenie manganu i zelaza\nZakres:\nMn (0,004 – 2,0) mg/dm3\nFe (0,008 – 4,0) mg/dm3\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-20/JS wydanie 5 z dnia 6.12.2022r.","categories":["water"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Mn","range":"(0,004 – 2,0) mg/dm3"},{"name":"Fe","range":"(0,008 – 4,0) mg/dm3"}],"search_en":"Water Flame atomic absorption spectrometry (FAAS) Mn Fe PB-20/JŚ wydanie 5 z dnia 6.12.2022r.","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Water","search_zh":"水 火焰原子吸收光谱法（FAAS） Mn Fe PB-20/JŚ wydanie 5 z dnia 6.12.2022r.","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水","parameters_zh":[{"name":"Mn","range":"(0,004 – 2,0) mg/dm3"},{"name":"Fe","range":"(0,008 – 4,0) mg/dm3"}]},{"_id":"6a7f1fc5bc25eed9be28d9bf","lab_id":"69ad52a3de79e566650fb5f8","country":"PL","accr_number":"AB 1168","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie rtęci","parameters":[{"name":"Zakres","range":"(0,0002 − 0,3) mg/dm3"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","techniques":["Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji"],"computed":[],"activity":"Stężenie rtęci\nZakres (0,0002 − 0,3) mg/dm3\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"PB-04/JŚ wydanie 12 z dnia 6.12.2022r.","norm_bases":["PB-04/JŚ wydanie 12 z dnia 6.12.2022r."],"lab_section":"Pracownia AMA i ASA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie rtęci\nZakres (0,0002 − 0,3) mg/dm3\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji PB-04/JŚ wydanie 12 z dnia 6.12.2022r. Woda, scieki Stezenie rteci\nZakres (0,0002 − 0,3) mg/dm3\nMetoda absorpcyjnej spektrometrii atomowej z technika amalgamacji PB-04/JS wydanie 12 z dnia 6.12.2022r.","categories":["water"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury concentration","parameters_en":[{"name":"Range","range":"(0,0002 − 0,3) mg/dm3"}],"search_en":"Water, wastewater Mercury concentration Atomic absorption spectrometry with amalgamation technique Range PB-04/JŚ wydanie 12 z dnia 6.12.2022r.","technique_en":"Atomic absorption spectrometry with amalgamation technique","test_object_en":"Water, wastewater","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,0002 − 0,3) mg/dm3"}],"search_zh":"水、废水 汞浓度 原子吸收光谱法（汞齐化技术） 范围 PB-04/JŚ wydanie 12 z dnia 6.12.2022r.","technique_zh":"原子吸收光谱法（汞齐化技术）","test_object_zh":"水、废水"},{"_id":"6a7f1fc5bc25eed9be28d9c0","lab_id":"69ad52a3de79e566650fb5f8","country":"PL","accr_number":"AB 1168","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT","parameters":[{"name":"Zakres","range":"(5 – 25000) mg/dm3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT\nZakres (5 – 25000) mg/dm3\nMetoda miareczkowa","reference":"PB-13/JŚ wydanie 6 z dnia 6.12.2022r.","norm_bases":["PB-13/JŚ wydanie 6 z dnia 6.12.2022r."],"lab_section":"Pracownia Wód i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu - ChZT\nZakres (5 – 25000) mg/dm3\nMetoda miareczkowa PB-13/JŚ wydanie 6 z dnia 6.12.2022r. Woda, scieki Chemiczne zapotrzebowanie tlenu - ChZT\nZakres (5 – 25000) mg/dm3\nMetoda miareczkowa PB-13/JS wydanie 6 z dnia 6.12.2022r.","categories":["water"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand - COD","parameters_en":[{"name":"Range","range":"(5 – 25000) mg/dm3"}],"search_en":"Water, wastewater Chemical oxygen demand - COD Titrimetric method Range PB-13/JŚ wydanie 6 z dnia 6.12.2022r.","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"化学需氧量 ChZT（COD）","parameters_zh":[{"name":"范围","range":"(5 – 25000) mg/dm3"}],"search_zh":"水、废水 化学需氧量 ChZT（COD） 滴定法 范围 PB-13/JŚ wydanie 6 z dnia 6.12.2022r.","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a7f1fc5bc25eed9be28d9c1","lab_id":"69ad52a3de79e566650fb5f8","country":"PL","accr_number":"AB 1168","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(2,5 – 1000) mg/dm3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (2,5 – 1000) mg/dm3\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Pracownia Wód i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie chlorków\nZakres (2,5 – 1000) mg/dm3\nMetoda miareczkowa PN-ISO 9297:1994 Woda, scieki Stezenie chlorkow\nZakres (2,5 – 1000) mg/dm3\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(2,5 – 1000) mg/dm3"}],"search_en":"Water, wastewater Chloride concentration Titrimetric method Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(2,5 – 1000) mg/dm3"}],"search_zh":"水、废水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a7f1fc5bc25eed9be28d9c2","lab_id":"69ad52a3de79e566650fb5f8","country":"PL","accr_number":"AB 1168","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie ortofosforanów","parameters":[{"name":"Zakres","range":"(0,025 – 6,0) mg/dm3 PO4"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie ortofosforanów\nZakres (0,025 – 6,0) mg/dm3 PO4\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 punkt 4 +Ap1:2010 +Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 punkt 4 +Ap1:2010 +Ap2:2010"],"lab_section":"Pracownia Wód i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie ortofosforanów\nZakres (0,025 – 6,0) mg/dm3 PO4\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 punkt 4 +Ap1:2010 +Ap2:2010 Woda, scieki Stezenie ortofosforanow\nZakres (0,025 – 6,0) mg/dm3 PO4\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 punkt 4 +Ap1:2010 +Ap2:2010","categories":["water"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Orthophosphate concentration","parameters_en":[{"name":"Range","range":"(0,025 – 6,0) mg/dm3 PO4"}],"search_en":"Water, wastewater Orthophosphate concentration Spectrophotometric method Range PN-EN ISO 6878:2006 punkt 4 +Ap1:2010 +Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,025 – 6,0) mg/dm3 PO4"}],"search_zh":"水、废水 正磷酸盐浓度 分光光度法 范围 PN-EN ISO 6878:2006 punkt 4 +Ap1:2010 +Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"正磷酸盐浓度"}],"has_pdf":true}