🇵🇱 MIEJSKO-PRZEMYSŁOWA OCZYSZCZALNIA ŚCIEKÓW Sp. z o.o. PL

PCA AB 1160 • Oświęcim, Poland • 38 methods

Water & wastewaterPetrochemistry & fuelsEnvironment

MIEJSKO-PRZEMYSŁOWA OCZYSZCZALNIA ŚCIEKÓW Sp. z o.o. is a laboratory accredited by PCA under number AB 1160 (Oświęcim, Poland). Its accreditation scope covers 38 test methods in the following areas: Water & wastewater, Petrochemistry & fuels, Environment. Test objects include: Water, wastewater, Solid fuels - hard coal, Rainwater, snowmelt water, Waste O): code 02 02 04, 02 02 99, 02 03 05, 02 05 01, 02 06 01, 04….

At a glance

  • Accreditation number: PCA AB 1160
  • Methods in scope: 38
  • Types of test objects: 7
  • City: Oświęcim, Poland
Accreditation number
AB 1160
Accreditation body
PCA
Address
LABORATORIUM, ul. Nadwiślańska 46, 32-600 Oświęcim
City
Oświęcim, Poland

What this laboratory tests (7)

Accreditation scope — test methods (38)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Solid fuels - hard coal Total carbon content (TC) Range: (40,0 – 85,0) % High-temperature combustion method with IR detection PN-G-04571:1998
2 Solid fuels - hard coal Total sulfur content Range: (0,20 – 2,00) % High-temperature combustion method with IR detection PN-G-04584:2001
3 Solid fuels - hard coal Ash content Range: (5,0 – 35,0) % Gravimetric method PN-ISO 1171:2002
4 Solid fuels - hard coal First-stage moisture content (transient moisture) Range: (1,0 – 15,0) % Gravimetric method PN-ISO 589:2006
5 Solid fuels - hard coal Second-stage moisture content (moisture remaining in the sample) Range: (0,5 – 15,0) % Gravimetric method PN-ISO 589:2006 met. A1 i A2
6 Solid fuels - hard coal Total moisture content (calculated) PN-ISO 589:2006 met. A
7 Solid fuels - hard coal Moisture content in the analytical sample Range: (0,5 – 15,0) % Gravimetric method PN-ISO 11722:2009
8 Solid fuels - hard coal Hydrogen content Range: (3,00 – 5,00) % High-temperature combustion method with IR detection PN-G-04571:1998
9 Solid fuels - hard coal Gross calorific value Range: (16000 – 35000) J/g Calorimetric method Net calorific value (calculated) PN-ISO 1928:2020-05
10 Waste O): code 10 01 01, 10 01 02 Total carbon content (TC) Range: (0,5 – 42,0) % High-temperature combustion method with IR detection PB-01 wydanie VI z dnia 10.12.2018 r.
11 Water, wastewater pH Range: 3,0 – 12,0 Potentiometric method PN-EN ISO 10523:2012
12 Water, wastewater Chemical oxygen demand − COD-Cr Range: (30 – 10000) mg/l O 2 Titrimetric method PB-03 wydanie II z dnia 31.08.2011 r.
13 Water, wastewater Biochemical oxygen demand − BOD 5 Range: (0,5 – 6,0) mg/l O 2 Electrochemical method PN-EN 1899-2:2002
14 Water, wastewater Biochemical oxygen demand − BOD 5 Range: (6 – 3000) mg/l O 2 Electrochemical method PN-EN ISO 5815-1:2019-12
15 Water, wastewater Total phosphorus concentration Range: (0,065 – 65,0) mg/l Spectrophotometric method PN-EN ISO 6878:2006 p. 8 +Ap1:2010+Ap2:2010
16 Water, wastewater Total nitrogen concentration Range: (1,00 – 200) mg/l Spectrophotometric method PB-06 wydanie IV z dnia 27.10.2017 r. na podstawie testów kuwetowych HACH LANGE LCK 138, 238, 338
17 Water, wastewater Total suspended solids (TSS) Range: (5,0 – 1000) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007
18 Water, wastewater Dissolved solids concentration Range: (100 – 100000) mg/l Gravimetric method PN-78/C-04541 p. 4.4
19 Water, wastewater Phenol index Range: (0,002 – 1,0) mg/l Spectrophotometric method PN-ISO 6439:1994 met. B
20 Water, wastewater Ammonium nitrogen concentration Range: (2,00 – 200) mg/l Titrimetric method PN-ISO 5664:2002
21 Water, wastewater Ammonium nitrogen concentration Range: (0,200 – 2,00) mg/l Spectrophotometric method PN-ISO 7150-1:2002
22 Water, wastewater Sulfate concentration Range: (10 - 1000) mg/l Gravimetric method PN-ISO 9280:2002
23 Water, wastewater Metal concentrations Range: lead (0,200 – 10,0) mg/l zinc (0,050 – 20,0) mg/l nickel (0,200 – 10,0) mg/l copper (0,050 – 6,0) mg/l Flame atomic absorption spectrometry method (FAAS) PN-ISO 8288:2002 met. A
24 Water, wastewater Chromium concentration Range: (0,100 – 10,0) mg/l Flame atomic absorption spectrometry method (FAAS) PB-08 wydanie I z dnia 20.07.2011 r.
25 Water, wastewater Electrical conductivity Range: (200 − 5000) μS/cm Conductometric method PN-EN 27888:1999
26 Water, wastewater Sulphide concentration Range: (0,100 – 2,00) mg/l Spectrophotometric method PB-20 wydanie I z dnia 05.09.2023 r.
27 Water, wastewater Metal concentrations Range: cadmium (0,0004 – 0,040) mg/l nickel (0,007 – 0,200) mg/l copper (0,0030 – 0,060) mg/l lead (0,010 – 0,500) mg/l chromium (0,0020 – 0,200) mg/l arsenic (0,005 – 1,0) mg/l vanadium (0,007 – 3,0) mg/l silver (0,0015 – 3,0) mg/l Electrothermal atomization atomic absorption spectrometry (ETAAS) PN-EN ISO 15586:2005
28 Water, wastewater Nitrate nitrogen concentration Range: (0,230 – 27,0) mg/l Spectrophotometric method PB-10 wydanie I z dnia 04.06.2013 r. na podstawie testu kuwetowego HACH LANGE LCK 339
29 Water, wastewater Petroleum ether extractable substances Range: (1,0 – 100) mg/l Gravimetric method PN-86/C-04573.01
30 Water, wastewater Anionic surfactant concentration Range: (0,100 – 20,0) mg/l Spectrophotometric method PN-EN 903:2002
31 Water, wastewater Chemical oxygen demand – COD-Cr Range: (30 – 10000) mg/l Titrimetric method PN-ISO 6060:2006
32 Water, wastewater Chloride concentration Range: (5,0 – 1000) mg/l Titrimetric method PN-ISO 9297:1994
33 Water, wastewater Non-ionic surfactant concentration Range: (0,200 – 30,0) mg/l Spectrophotometric method PB-17 wydanie I z dnia 10.05.2021 r. na podstawie testu kuwetowego HACH LANGE LCK 333
34 Water, wastewater Nitrite nitrogen concentration Range: (0,015 – 6,0) mg/l Spectrophotometric method PB-16 wydanie I z dnia 10.05.2021 r. na podstawie testu kuwetowego HACH LANGE LCK 341, 342
35 Wastewater Sampling for chemical and physical testing Manual method Automatic method PN-ISO 5667-10:2021-11
36 Rainwater, snowmelt water Sampling for chemical and physical testing Manual method PN-ISO 5667-10:2021-11
37 Waste O): code 02 02 04, 02 02 99, 02 03 05, 02 05 01, 02 06 01, 04 01 07, 06 03 14, 07 01 80, 07 01 99, 10 01 80, 12 03 01*, 19 05 03, 19 05 99, 19 08 01, 19 08 02, 19 08 05, 19 08 09, 19 08 10*, 19 08 14, 19 08 99, 19 12 12, 20 02 01 Dry matter Range: (1,0 – 99,5)% Gravimetric method PN-EN 14346:2011 metoda A
38 Waste O): code 19 05 03, 19 05 99, 19 12 12 Sampling for chemical and physical testing PN-Z-15011-1:1998

Reference standards (36)

PB-01 wydanie VI z dnia 10.12.2018 r.
PB-03 wydanie II z dnia 31.08.2011 r.
PB-06 wydanie IV z dnia 27.10.2017 r. na podstawie testów kuwetowych HACH LANGE LCK 138, 238, 338
PB-08 wydanie I z dnia 20.07.2011 r.
PB-10 wydanie I z dnia 04.06.2013 r. na podstawie testu kuwetowego HACH LANGE LCK 339
PB-16 wydanie I z dnia 10.05.2021 r. na podstawie testu kuwetowego HACH LANGE LCK 341, 342
PB-17 wydanie I z dnia 10.05.2021 r. na podstawie testu kuwetowego HACH LANGE LCK 333
PB-20 wydanie I z dnia 05.09.2023 r.
PN-78/C-04541 p. 4.4
PN-86/C-04573.01
PN-EN 14346:2011 metoda A
PN-EN 1899-2:2002
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN 903:2002
PN-EN ISO 10523:2012
PN-EN ISO 15586:2005
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6878:2006 p. 8 +Ap1:2010+Ap2:2010
PN-G-04571:1998
PN-G-04584:2001
PN-ISO 1171:2002
PN-ISO 11722:2009
PN-ISO 1928:2020-05
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 589:2006
PN-ISO 589:2006 met. A
PN-ISO 589:2006 met. A1 i A2
PN-ISO 6060:2006
PN-ISO 6439:1994 met. B
PN-ISO 7150-1:2002
PN-ISO 8288:2002 met. A
PN-ISO 9280:2002
PN-ISO 9297:1994
PN-Z-15011-1:1998