🇵🇱 POWIATOWA STACJA SANITARNO – EPIDEMIOLOGICZNA PL

PCA AB 1152 • Iława, Poland • 17 methods

Water & wastewaterMicrobiologyEnvironment

POWIATOWA STACJA SANITARNO – EPIDEMIOLOGICZNA is a laboratory accredited by PCA under number AB 1152 (Iława, Poland). Its accreditation scope covers 17 test methods in the following areas: Water & wastewater, Microbiology, Environment. Test objects include: Water, water intended for human consumption, Swimming pool water, Faeces, rectal swab, Workplace environment - indoor electric lighting.

At a glance

  • Accreditation number: PCA AB 1152
  • Methods in scope: 17
  • Types of test objects: 7
  • City: Iława, Poland
Accreditation number
AB 1152
Accreditation body
PCA
Address
W IŁAWIE, ul. Sienkiewicza 10, 14-200 Iława
City
Iława, Poland

What this laboratory tests (7)

Accreditation scope — test methods (17)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Workplace environment - noise A-weighted equivalent sound level A-weighted maximum sound level Range: (44 – 135) dB C-weighted peak sound level Range: (44 – 138) dB Direct measurement method PN-EN-ISO 9612:2011 z wyłączeniem metod obejmujących strategię 2 i 3 – p. 10 i 11 PN-N-01307:1994
2 Workplace environment - noise Noise exposure level normalised to: -an 8-hour working day an average weekly working time (calculated)
3 Workplace environment - indoor electric lighting Illuminance Range: (20 – 5000) lx Direct measurement method PN-EN-83/E-04040.03 PB-SBŚP-03 edycja 4 z dnia 30.07.2024 r.
4 Workplace environment - indoor electric lighting Illuminance uniformity (calculated)
5 Water, water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 PN-EN ISO 9308-1:2014-12/A1:2017- 04
6 Water, water intended for human consumption Escherichia coli count Membrane filtration method
7 Water, water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
8 Water, water intended for human consumption Total microorganism count at 22°C and 36°C Plate method (pour plate) PN-EN ISO 6222:2004
9 Water, water intended for human consumption Most probable number of Escherichia coli Most probable number of coliform bacteria MPN method PN-EN ISO 9308-2:2014-06
10 Water, water intended for human consumption Count of bacteria of the genus Legionella Matrix A: Procedure 5 (medium A), Procedure 7 (medium C – GVPC) Membrane filtration method PN-EN ISO 11731:2017- 08+Ap1:2019-12
11 Swimming pool water Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009
12 Swimming pool water Coagulase-positive staphylococci count Membrane filtration method PN-Z-11001-3:2000 Załącznik A
13 Swimming pool water Count of bacteria of the genus Legionella Matrix A: Procedure 5 (medium A), Procedure 7 (medium C – GVPC) Membrane filtration method PN-EN ISO 11731:2017- 08+Ap1:2019-12
14 Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007
15 Water from bathing waters and bathing places Most probable number of Escherichia coli Miniaturised method (MPN) PN-EN ISO 9308-3:2002
16 Faeces, rectal swab Presence of Salmonella spp., Shigella spp. rods Culture method with biochemical and serological confirmation PB-SBM-04 edycja 4 z dnia 29.09.2022 r.
17 Faeces, rectal swab Presence and identification of Yersinia enterocolitica rods, Culture method with biochemical and serological confirmation PB-SBM-01 edycja 5 z dnia 29.09.2022 r.

Reference standards (13)

PB-SBM-01 edycja 5 z dnia 29.09.2022 r.
PB-SBM-04 edycja 4 z dnia 29.09.2022 r.
PN-EN ISO 11731:2017- 08+Ap1:2019-12
PN-EN ISO 16266:2009
PN-EN ISO 19458:2007
PN-EN ISO 6222:2004
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014-12 PN-EN ISO 9308-1:2014-12/A1:2017- 04
PN-EN ISO 9308-2:2014-06
PN-EN ISO 9308-3:2002
PN-EN-83/E-04040.03 PB-SBŚP-03 edycja 4 z dnia 30.07.2024 r.
PN-EN-ISO 9612:2011 z wyłączeniem metod obejmujących strategię 2 i 3 – p. 10 i 11 PN-N-01307:1994
PN-Z-11001-3:2000 Załącznik A